1. 1 Battery voltage review As shown as the right figure the displaying number is the present battery voltage This interface is the main interface and it shows the charging amp discharging state battery capacity and battery voltage 3 2 Load ON OFF controlling YSMART TECHNOLOGY CO LTD website www ysmart tech com Phone 86 755 85232255 At the battery voltage review interface you can press button to turn on or turn off the load while this button does not have this function at other interfaces 3 3 Environmental temperature review Be used for the temperature compensation when the battery ceases charging As shown as the right figure the displaying number is the surrounding environmental temperature of the controller 3 4 Review the generating current of solar panels As shown as the right figure the displaying number is the generating current of solar panels 3 5 The load current review As shown as the right figure the displaying number is the accumulating generating AH of solar panels 3 6 Review and clearing the accumulative generating AH of solar panels As shown as the right figure the displaying number is the accumulating generating AH of solar panels At this interface press button EI for long gt 5 seconds and it can clear accumulative generating AH 3 7 Review and clearing load accumulative discharging AH As shown as the right figure the displaying number is the accumulating
2. YSMART TECHNOLOGY CO LTD website www ysmart tech com Phone 86 755 85232255 Intelligent Solar Charge Controller Solar30 User s Manual CE A V SOLAR30 N ee ee f sah He SA 8O Se ai 2 oe wy Gre wa ow be 0 0 au 1 Product introduction This controller is a kind of intelligent and multifunctional solar charge controller These serial products adopt customized LCD display screen which makes the operation on the interface rather convenient e Visual LCD graphic symbol e Brief key operation e Grade auto switch of system voltage e Intelligent PWM Charging Mode e Auto temperature compensation e Adjustable charging amp discharging parameter e Settable working modes of loads e Accumulative function of charging amp discharging AH e Protection for battery back discharging e Protection for battery low voltage e Overloading amp short circuit protection e Battery reversed protection e Delayed auto restart after overloading protection 2 Installation Explanation Installation Get ready the related tools amp cables We suggest you choose the appropriate cables to ensure the current density lt 4A mm and this is good for reducing cable voltage drop Recommendation 30A using 10mm cable 50A using 16 mm cable YSMART TECHNOLOGY CO LTD website www ysmart tech com 1 Check whether installation place accords Temperature sensor interface with the relative safety rules Please avoid ins
3. g after dawn At this interface press button for long 5 seconds the number starts to flicker and it means the controller enters into the interface of setting the load modes Use button 04 to adjust this parameter After finishing setting press button Et for long gt 5 seconds to exit this interface and the controller can store this setting number Breakdown amp disposal Low voltage protection amp disposal If the screen shows as the right figure it means the battery voltage is lower than the protection voltage The controller enters into the low voltage protection state and the load loop disconnects Use the solar panels or charger to charge for the battery When battery voltage recovers to the protection voltage the controller will recover to supply power for load and enter into the working state Overloading protection amp disposal If the screen shows as the right figure and the light flickers it means the current of the load loop is 1 2 times of the rated current within 3 seconds and the controller is at overloading state After removing some loads the controller will supply power to the loads automatically within seconds or you can press button 7 to recover the power supply compulsively Short circuit protection amp disposal If the screen shows as the right figure and the light flickers i means there happens short circuit in the load loop and the controller is at short circuit protecti
4. generating AH of solar panels At this interface press button EI for long gt 5 seconds and it can clear accumulative generating AH 3 8 Review and setting low voltage protection function As shown as the right figure the displaying number is the protection voltage And if the battery voltage is lower than this voltage the YSMART TECHNOLOGY CO LTD website www ysmart tech com Phone 86 755 85232255 controller will disconnect the load loop to prevent the battery from over discharging At this interface press button E for long gt 5 seconds the number starts to flicker and it means the controller enters into the interface of setting the protection voltage Use button to adjust this parameter After finishing setting press button Et for long 5 seconds to exit this interface and the controller can store this setting number 3 9 Review and setting recovering voltage for low voltage condition As shown as the right figure the displaying number is the recovery numbe1 After the controller enters into low voltage protection state and when the battery voltage recovers to be higher than the recovering voltage then the controller will reconnect the load loop automatically At this interface press button E for long gt 5 seconds the number starts to flicker and it means the controller enters into the interface of setting the recovery voltage Use button 704 to adjust this parameter After finishing setting
5. of system YSMART TECHNOLOGY CO LTD website www ysmart tech com Phone 86 755 85232255 Battery icon 2 Explanation of button function t Interfaces circular toggling button Use this button can realize the toggling circularly among the interfaces The circular order is as follows as shown as figure 1 Parameter adjusting button Besides under parameter review condition press this button for over 5 seconds and all the parameters will recover to the ex work setting State q Parameter adjusting button Besides at the main interface this button can turn on or turn off the load Battery voltage battery Solar panels load discharging accumulative main interface temperature generating current current generating AH Load working ceasing charging recovery voltage low voltage accumulative state voltage protection poin discharging AH 3 Parameter review and setting After the controller electrifies right it will enter into the displaying interface of battery voltage ty This interface is the main interface of the controller Press button to go through the ty interfaces of the following parameters If the interface can be reset press button for long gt 5 seconds and the number on the interface starts to flicker then it enters into the setting interface of this parameter ty After finishing setting press button for long to exit the setting interface and the number stops flickering 3
6. on state Please check whether the loads are damaged and whether the connecting cables are short circuit After eliminating the breakdown press button SS to recover the power supply for the loads Breakdown amp disposal of solar panels YSMART TECHNOLOGY CO LTD website www ysmart tech com Phone 86 755 85232255 Sign flickering means the controller do not detect the existence of solar panels Please check whether the connecting with the solar panels is in good condition and check whether the cables connecting the solar panels and the controller are in open circuit condition Load impulsion breakdown If P flickers when you turn on the load it means the starting impulsion current is more than twice of the rated working current Please restart the controller for times Other exceptional conditions Please contact the distributor or manufacturer Product Parameter SOLAR30 SOLAR30 mama n A pa ee low voltage protection settable 10 7V 21 4V 90 mm X 188 mm X 48 m
7. press button E for long gt 5 seconds to exit this interface and the controller can store this setting number 3 10 Review and setting the voltage of ceasing charging As shown as the right figure the displaying number is the voltage of ceasing charging When the battery voltage reaches up to this voltage the controller will disconnect the charging loop to prevent the battery from over charging After the battery voltage drops the controller will reconnect the charging loop At this interface press button EF for long gt 5 seconds the number starts to flicker and it means the controller enters into the interface of setting the voltage of ceasing charging Use button 7 4 to adjust this parameter After finishing setting press button EF for long gt 5 seconds to exit this interface and the controller can store this setting number 3 11 Review and setting the load mode As shown as the right figure it is the reviewing surface of the LOAD ON load mode Different numbers represent different load mode 24h indicating normal mode loads are under the condition of supplying power without breakdown Ih 23h indicating delayed mode of light control loads start YSMART TECHNOLOGY CO LTD website www ysmart tech com Phone 86 755 85232255 to supply power after dark and shun down after working for the delayed setting hours Oh indicating light control loads start to supply power after dark and stop workin
8. talling and using the controller under the following conditions wet dusty places or places with flammable and explosive gases 2 Install the controller at the vertical plane Please refer to chapter 5 for more detailed info about the spacing between the installing holes In order to make the controller have good thermal dissipation please sparel0cm above amp below the controller Phone 86 755 85232255 Controller 3 As shown as the right figure connect the loads battery and solar panels with the controller in order Pay attention to connect the loads battery and solar panels right 4 Plug the external thermal sensor into the interface of the thermal sensor on the left of the controller Disassemble To avoid the accident please dismantle the solar panels battery loads from the controller in order Attention Connecting the battery reversed will not damage the controller but will cause safety risk on your loads 3 Operation 1 Explanation of LCD Graphic Symbol Stop supplying power for loads Having current in load loop Load icon zn Supplying power for loads no current in load loop p Solar panels icon Load light controlling icon Stop charging for battery C T Load timing controlling icon Ry Charging for battery at full speed Wy nw Float charging for battery Battery capacity display asp Normal working state of system AN Abnormal working state