Home

gtgps configuration software user manual

image

Contents

1. 15 5 3 Window GSM communication options esses 18 5 4 Remote Control by Dialling Remote Control by Dialling sese 19 S Mow MODE mt 20 Aoc DUIS NN 22 2 4 Window Service text SUPITUADY OU eU Ora 28 Won NMES OT 29 5 9 Window Testing and Diagnostic window sees nennen nennen nnn nnns 30 6 Saving of GTGPS module configuration into iaa 32 7 Installing of saved configuration into the module 02 5 Updating ot Sony ale Vets Oi cs eese ed tua PRU Ou SIM a psu I tav ES CAM EE 33 1 Installation of SERA software Open the folder containing installation of the software SERA Click the file SERA setup exe from the mentioned folder it SERA configuration program InstallShield Wizard Welcome to the InstallShield Wizard for SERA configuration program The InstallShield P Wizard will install SERA configuration program on your computer To continue click Next WARMING This program is protected by copyright law and international treaties Cancel In the displayed Window Fig 1 press Next gt GTGPS software SERA www topkodas lt ie SERA configuration program InstallShield Wizard Destination Folder Click Next to install to this Folder ar click Change
2. gt Fig 29 GTGPS software SERA www topkodas lt Luggage opened Luggage closed fone Options Alarm Enabled Restore Enabled Explanation of fields of Inputs Alarm text Restore text Input Name Input Def GTGPS software SERA Zone Definition Zone Type Alarm SMS Text Restore SMS Text Zone Speed 200ms mz Event Repeat Timeout B08 Fone Action Disable window n o S 9 J J Iputnumbr O Input Name www topkodas lt It is the text which will be received by user after alarm response of appropriate sensor This text may be changed It is the text which will be received by a user after restore of appropriate sensor This text may be changed If the box is checked it means that the module will react towards alarm response of appropriate sensor If the box is not checked the module will not react towards alarm of the present input If the check box is checked it means that the module will react towards restore of appropriate sensor after alarm response If the check box is not checked the module will not react towards restore of the present input Input type you may select after scrolling menu e NC normally closed contact e NO normally open contact e EOL normally closed contact with 1 resistor Input operation type you may select after scrolling menu e Delay Entry zone Set Entry delay and Exit Delay are
3. SW send Test SMS from your module For this purpose press Update in the menu list or Update module icon Fig 45 Specify the file of the newest software version and press Open Follow further instructions of the program SERA Glauto configuration File Edit Setup Devices Update Help Sjal eje Update Module GTauto Configuration Fig 45 Select Firmware file of the module aopen x Look in i Firmwarellpdates Mame GTauto v3 enc 2010 07 23 14 49 Wireshark capture Recent Places GTauto vd enc AS Wireshark capture 2010 10 08 21 56 Wireshark capture i File name GTGPS enc Files of type Firmware files Cancel EZ GTGPS software SERA www topkodas lt 33 Press RESET button once and click in the displayed table Please connect and reset your hardware You will see the following progress bar at the bottom of the window GTGPS configuration im x File Setup Devices Update Help vstem Options p System Options GPS Settings GSM Communications GSM Alarm Pager GPS tracker AVL GEM Remote Control ardwvare details Outputs Installer password I 6 symbols cervice SMS Text User password 6 symbols GTGPS Custom SMS Text Test ae 24 h Reset test counter after arming Boot GTOGPZbant 1v
4. i 3 Input 3 Door opened Door closed v v HO a 4 Input 4 Microwave alarm MicrowaveRestore v HO Input 5 Ignition ON Ignition OFF NC 5 Input 6 Siren ON Siren OFF e wv NC B T Battery Low Batery Batery restore m C NC B Temperature Low Temperature Temp restore v NC special function Lociuu nlock Blocking condition Input Signal Time to Force ARM fs input Reaction Speed 100 Fig 33 IE input 1 Luggage opened Luggage closed 3 v NO i 2 Input 2 Bonnet opened Bonnet closed v v NO 3 Input 3 Door opened Door closed e m NO E 4 Input 4 Microwave alarm MicrowaveRestore v HO Hs Input 5 Ignition ON Ignition OFF O NC 5 Input 6 Siren ON Siren OFF e wv NC rj Battery Low Batery Batery restore m E NC Temperature Low Temperature Temp restore v NC Alarm voltage 19 w Calibration 2 28783 Restore voltage 13 52 v Fig 34 GTGPS software SERA www topkodas lt SSS eww wes Fig 35 21 t WWW topkodas l GTGPS software SERA 5 7 Window Service text summary In order to open Service text summary Window select Service text summary from the left section Name of Status Event 1 Module ARM System ARM Iv 2 Module DISARM System DISARM Iv 3 Module reset system reset m 4 Module Periodical Test Test 5 GPS Periodical Report GPS Report v B GPS Geofence Alarm Geofence Alarm m T GPS OverSpeed Ala
5. able to control the module by dialling should be entered in this column User number should be entered with international code OUT2 OUT3 O0UT4 Where the check boxes are checked these inputs will be switched if a user will call from this number Preferred input may be assigned to each user s number Thus different users are able to control different objects If this check box is checked a user will be able to ARM DISARM the security system by dialling MIC If this check box 1s checked a user will be able to activate microphone and to switch on voice listening GPS If this check box is checked when dialling to the module the module will send SMS with GPS coordinates to the number from which the call has been made GTGPS software SERA www topkodas lt 19 5 5 Window Outputs In order to open Window Outputs it is necessary to select Outputs option Outputs D Out ONSMStext OutOFF SMStext defintion Out pulse time State Mode Out OFF Out OFF Outs OFF Out4 OFF 1 2 Out Out2 ON B 3 Outs Outs ON B 4 Out4 Out4 ON 1 2 Out Out OM 3 Outs Outs OM 4 Out4 Ott OM Out OM SMS text Out OM SMS text Out OFF Out OFF Outs OFF Out4 OFF Out OFF Outs OFF Outs OFF Out4 OFF Explanation of fields of Outputs Window P Outpt 1D number Out ON text It is a text which will be sent to a user after activation of output by the module This
6. eral Device status This device is working properly IF are having probleme with this device click Troubleshoot to start the troubleshooter Device usage Use this device enable OF Cancel GTGPS software SERA www topkodas lt 9 3 Selection of COM port After installing drivers you should check what COM port number has been assigned to the USB module To perform this task in Windows environment follow the instructions mentioned below Attention The module should be connected to 12V connection leads black red and to a PC via USB interface Open the Window System Properties path Start gt Control Panel gt System System Properties Window Fig 9 is being displayed From the Window System properties select the tab Hardware After selection of the tab Hardware Window Fig 9 will be displayed System Properties System Restore Automatic Updates Remote General Computer Mame i Hardware i Advanced Device Manager The Device Manager lists all the hardware devices installed E onyour computer Use the Device Manager to change the properties of any device Device Manager Drivers Driver Signing lets you make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Hardware Protiles m Hardware profiles provide a way for you ta set up and store ei diffe
7. on the module are active and indicate activity of the module Off energy saving mode lights only red LED operation of GSM modem is being indicated red control LED is on bus leads are always on not depending on Indication mode Siren Signal on ARM DISARM When the function is active and the security system 1s turned into ARM state siren will beep once when turning into DISARM state it will beep twice Auto re ARM Automated activation of the system if a door has nor been closed after DISARMing the system Temperature It is temperature scale Two scale types are possible one of which may be selected after scrolling menu near the note Temperature e Celsius temperature indications according to Celsius scale e Fahrenheit temperature indications according to Fahrenheit scale Hardware details This 1s info about GTGPS module HW hardware version of the module Mode 3 Mode 3 V Level using Lock input uses only one Lock input Unlock input is not used These modes are comfortable to use when activating deactivating the system by using switch or other access control device Mode 4 Mode 4 V Level using Lock input as in 3 mode only inverted Mode 5 Mode 5 V gt 500ms Pulse Lock input used only one Lock input Unlock input is not used The module ARM DISARM state may be changed via voltage pulse longer than 500ms It is possible to use a button or other control device which will generate vol
8. smoke sensors and for fire alarm It is the time in milliseconds which indicates the shortest signal for reaction of the module If signal is shorter than indicated the module will ignore it The time period in seconds during this time repeatable zone events are ignored Additional input function Lock Unlock blockage conditions The following settings are possible Disable additional function off Unlock Blocking condition Lock Blocking condition Lock Unlock Blocking condition Input reaction speed In7 forced ARMing special function Disable additional function off Unlock Blocking condition Lock Blocking condition Lock Unlock Blocking condition Force Arming if the module is in DISARM state thus after selecting this function the module will go to ARM mode after alarm response of Input7 siren zone Min siren time it 1S time in Seconds indicating the time period the siren should be active in order to trigger that zone Input reaction speed In8 Low Battery parameters e Alarm voltage voltage the module is connected to when this voltage is reached the 8 zone will be alarmed Restore voltage voltage the module is connected to when this voltage is reached the 8 zone will be restored Calibration coefficient if changed voltage indications might be calibrated In9 Temperature parameters e Alarm temperature when this temperature will be reached 9 zone will be alarmed e Restore temperature w
9. software SERA 12 If you are sure that the module is fully connected to PC and power supply please go to Devices gt GTGPS v1 Fig File Setup Devices Update Help aT auto v3 ST auto v4 13 Fig 13 After you make a selection configuration window System Options will be opened Fig 14 GTGPS configuration E n x File Setup Devices Update Help system Options GTGPS Configuration System Options GPS Settings GSM Communications GSM Alarm Pager GPS tracker AVL GEM Remote Control d detail Outputs Installer password B symbols kXXxkk k cervice EMS Text User password 6 symbols GTGPS Z Custom SMS Text eet we 24 h Resettest counter after arming Boot GTGPZbant 1v Testing and Diagnostic Lacanek Mode 1 Cv Pulse using Lack and Unlock inputs At GTGPZ 1 101008 Entry Delay s s Exit Delay f Siren time f 20 v Siren signal on ARM DISARM celcius Suto re amp RM w Indication on off energy saving FC time 2010 10 08 22 00 50 CON Disconnected GTGPS v1 101008 27 Fig 14 Set the port to initialize GTGPS Go to Setup gt Serial Port Fig 15 File Edit Sait Devices Update Help gt Fig 15 Window Serial Port Setup should be displayed Fig 16 Scroll the list and select COM port you saw in Device Manager window In th
10. text may be changed Out OFF text Out OFF SMS text Out OFF SMS text CTRL SMS DIAL 15 Pulse SIREN 600s w Steady ARM state 600s Steady Light Flash BOs Steady x Fig 24 Out definition a Out pulse time Invert State Mode NE MEME con Steady SIREN 5 6005 Steady ztate 00 E Steady Inputs OK Light Flash Fig 25 Out definition Out pulse time invert CTRL SMS DIAL 15s SIREN 600s rJ ARM state 600s Pulse Light Flash 600z Beh Fig 26 It is a text which will be sent to a user after deactivation of output by the module This text may be changed Out definition Output activity algorithm may be selected from scrolled menu seeFig 25 GTGPS software SERA www topkodas lt 20 State mode GTGPS software SERA Out pulse time www topkodas lt CTRL SMS DIAL output will be possible to control via SMS message short call or commutation via selected input This algorithm may be used for ignition blocking for gate control or for remoter starting of a car etc SIREN output used for connection of siren Used for generating of voice signal in the event of alarm BUZER sound signalling device Upon alarm of the zone beeps continuously When security system starts calculating Exit time Exit Delay the user is able to hear short voice signals When 10 seconds are left till the activation signals are being r
11. 5 4 Remote Control by Dialling Remote Control by Dialling To open Window Remote Control by Dialling it is necessary to select GSM Remote Control A window Fig 23 will be displayed including users table These users would be able to control the module by dialling The module will identify caller ID and if this ID will be available in the table the module will perform selected action It is possible to select few actions for one number however some of these actions may disturb each other e g if MIC and GPS are selected In such case the microphone will not be able to be turned on because when sending SMS with GPS parameters the module will automatically reject the call User number up to 400 Remote Control by Dialing userPhone ourt ouz outs outs Armiisarm Mc GPS EN pinipnin n ola Please note that all phone numbers must start with country code area code phone For example 1477511111111 1415111111111 ua c som me Cc LC LOCALE E 0 0 a aoa OO 0 0 0 0 Oy 0 0 0 0 9 0 0 ad D n Be w RB c Fig 23 Explanation of fields of Remote Control by Dialling ID numter of a user who is able to control the module by dialling up to 400 Remote User Phone Telephone numbers of users who will be
12. C has found file necessary for drivers installation and successfully installed it Press Finish Installation of USB Serial Config is finished GTGPS software SERA www topkodas lt lox File Action wiew Help 2A Realtek RTL8159 8110 Family Gigabit Ethernet NIC 5 d Other devices be Modem Device on High Definition Audio Bus HM Parts COM amp LPT oo Sg BT Port COMID e V BT Port COMI1 7 BT Port COMI2 7 BT Port COM13 e BT Port 1 BT Port 2 BT Port COM21 BT Port COM4D e BT Port COM41 y BT Port COM42 e BT Port COM43 e BT Port COME uw BT Port COM USE Serial Config CON 3 sto Processors 8 Secure Digital hast controllers El y System devices H Sound video and controllers Open Device Manager window and in the row COM amp LPT press in order to see all PC COM ports The row should show USB Serial Config COMx Drag mouse cursor on this row and right click on the menu item Properties You should see the window below with the note This device is working properly This means that PC is successfully prepared for operation with configuration testing application SERA USB Serial Config COM3 Properties xl General Fort Settings Driver Details E USB Serial Config COM3 Device tupe Ports COM LPT hanufacturer USBContig Location Location LU LIS BS
13. Double click on the selected line in order to open input settings window see Fig 30 nputzs a CN CNET DE TN Input 1 Luggage opened Luggage closed Iv v E eee nora Om ee 3 Input 3 Door opened Door closed v we NO B 4 Input 4 Microwave alarm MicrawaveRestare v No n Input 5 Ignition ON Ignition OFF NC B B Input Siren ON Siren OFF r MC B Battery Low Batery Batery restore m E NC x Temperature Low Temperature Temp restore NC Input Mame Alarm text Fig 27 Restore text Restore 1 Input 1 Luggage opened Luggage closed we m 2 Input 2 Bonnet opened Bonnet closed we i 3 Input 3 Door opened Door clazed Iv 4 Input 4 Microwave alarm Microwwaverestore we E 5 Input 5 lnition Ignition OFF we B Input 6 Siren ON Siren OFF we T Battery Low Batery Batery restore E B Temperature Low Temperature Temp restore we Fig 28 b Restore M M EOL delay Y Z00ms 60s Disable Restore 2 00 60s Disable _ Restore IN3 r4 iw EUL z ms 60s Disable inst ant Restore 4 Gl Gl EOL 24 hours Doms 60s Disable Restore IHS Gl Gl EOL silent 5Oms 60s Disable Restore n n wo fire 1000ms 60s Disable IN M v NO 24 hours 5000ms 60s Disable Batery restore iw iw silent 65000ms 6000s Disable Tenp reztore iw n NC silent 65000ms 6000s Disable
14. E controllers IEEE 1394 Bus host controllers A Imaging devices m Keyboards tl Memory technology driver n Mice and other pointing devices A Monitors Lu Metwork adapters m Ft USB serial Port con F USB Serial Port fi Processors System devices 4 Sound video and game controllers Universal Serial Bus controllers Fig 11 GTGPS software SERA www topkodas lt 11 From the displayed Window Fig 11 you must check what COM port is assigned to USB interface USB Serial Port COM3 is displayed in the example This means that USB will be assigned to the third COM port Remember this COM port number and proceed with the clause Work with the software SERA 4 Connection of the module to your PC The module must be powered with 12V gt 500mA voltage it should have inserted SIM card with replenished account and removed PIN CODE REQUEST connected GSM and GPS antennas and the module must be connected to the PC via programming cable Run SERA exe USB Cable 5 Work with the software SERA Start the software SERA Go to Start gt programs gt Topkodas gt SERA gt SERA or go to installation directory and click SERA exe SERA File Edit Setup Devices Update Help alaj xala ea ual el Change in the CTS line Change in the DSR line Change in the RLSD COMZ is opened 2 Connected 4 Fig 12 GTGPS
15. Topkodas SERA GTGPS v1 configuration and testing software in Microsoft Windows environment User s guide GTGPS configuration File Setup Devices Update Help c lal Bs e GTGPS Configuration System Options p System Optionz GPS Settings GSM Communications GSM Alarm Pager GPS tracker AVL GSM Remote Control d detail Outputs Installer password 6 symbols PO Inputs kkxkik Service SMS Text User password 6 symbols GTGPS Custom SMS Text Test time 24 Reset test counter after arming GTGPZboot 1vD Testing and Diagnostic een deis Mode 1 C Pulse using Lack and Unlock inputs At GTGPZ 1 101008 Entry Delay s Exit Delay f Siren time f 20 v Siren signal on ARM DISARM celcius Suto re amp RM w Indication on off energy saving FC time 2010 10 08 22 00 50 0 x COM Disconnected GTGPS vi 101008 27 Content I NS Gem TA OnE SERA SOLDES cusan dI IR UD EMEN ENIMS UE 2 2 4 MEC 6 0 0 COM eer 10 4 Connecaomot the INOdUIC tO YOUR PO aa ccccsteeiswianch coms sdonsssianesacacedeuiawiausuntas REES 12 S5 ODE vus NS SEIS iras 12 SL Contentofthe AON ess cs qune ED aH 14 5 2 Main Window of the software SERA System
16. VER Drive configuration is available in the file usbser inf After connection of USB cable the module must be supplied with 12V to the PC via USB interface OS Windows will find USB driver Driver configuration Windows XP usbser inf Windows 7 x86 or x64 usbser_x86_x64 inf Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation or on the Windows Update Web site with pour permission Can Windows connect ta Windows Update to search software CO Yes this time only Yes now and every time connect a device No nat this time Click Nest to continue Fig 5 Select No not this in the displayed Window Fig 5 and press Next gt GTGPS software SERA www topkodas lt 4 Hardware Update Wizard Welcome to the Hardware Update Wizard This wizard helps you install software for USB Serial If your hardware came with an installation CD lt floppy disk insert it now What want the wizard to da C nstall the software automatically Recommended Fig 6 Select Install from a list or specific location Advanced and press Next gt in the displayed Window Fig 6 Hardware Update Wizard Please choose your search and installation options Search for the best driver in these locati
17. a code phone For example 4477511111111 Iv Ive 3477511111111 i 1 Sending SMS AlarnRestore ialing ta USER Alarm Restore y a Select All 5 Select All INS v INS B PROF Limit IN6 O E m P P Limit of dialing v System voltage System voltage Temperature Temperature M ARM ARM T T v DISARM DISARM Service Service t w TEST TEST v GPS GPs Fig 21 Fig 22 Explanation of fields of GSM communication options Window DOD of the user to whom send SMS and make a call User Phone SMS and DIAL This column includes user numbers to whom GSM SMS messages will be sent and short calls will be made User number should be entered with international code Sending SMS Alarm Restore The events with check boxes will be send to selected users via SMS Dialling to USER Alarm Restore A user will be notified about these events the check bow should be checked by making him a short call Limit of dialling It is a figure which specifies how many times to call to a user s telephone number in the event of alarm or if a user does not cancel call of the module If a user after 15 sec will reject call the module will stop making calls till another event GTGPS software SERA www topkodas lt 18
18. applied for this zone Such type zones are used for connection of door sensor e Interior disturbance of this zone will not be responded if alarm of Delay type zone occurred and Entry Delay or Exit Delay time still have not expired Such type zones may be used for connection of motion sensor in front of the door The input will be activated immediately if the door has not been open before e Instant Instant zone Upon disturbance of this zone the system will immediately activate burglary alarm If the security system was ARM ed e 24hours Upon disturbance of this zone the system will activate burglary alarm not depending whether the security system is ARM or DISARM The applications of this type 23 Input speed Repeat time Input 4 Fig 31 Input 6 Fig 33 Battery Fig Temperature Fig 35 GTGPS software SERA www topkodas lt zones are safes storehouses tampers of the sensors e Silent silent zone is always active not depending on whether the security system 1s ARM or DISARM Upon disturbance of this zone SMS messages are being generated but the siren will not be activated These zones may be applied for voltage temperature control AC mains failure control and for alarm of silent panic e Fire this zone is always active not depending on whether the security system is ARM or DISARM The zone generates a special siren signal with interruptions The zone is applied for
19. e block of LOCK UNLOCK inputs The module will show no reaction towards signals in LOCK and UNLOCK inputs Mode 1 Mode 1 V Pulse using Lock and Unlock inputs uses two inputs 1 Lock and Unlock Lock input sets ARM mode after pulsing or steady signal Unlock sets DISARM mode It is comfortable to use 1 or 2 mode when connecting the module to the central lock of vehicle Central lock mostly generates lock and unlock signals with two wires Mode 2 Mode 2 V Pulse using Lock and Unlock inputs as in 1 mode only inverted 15 Entry Delay Input time in seconds The system starts calculating this time period after Delay type zone breaking If during that time the security system will not be disarmed The module will activate alarm state 1 e siren will be switch on and SMS will be send about alarmed zones Entry Delay It is insensibility time seconds of the module into Delay and Interior type inputs before the module enters to ARM mode This means that during calculation of this time period the module will not activate alarm even if inputs will be activated Siren Time This time value specifies how long the Siren of security system will be active after occurrence of alarm Time period should be set in seconds from 1 sec to 999 sec Indication on off energy saving if this box is checked it means that setting 1s On If the box 1s not checked the setting 15 1n off energy saving e On mode all LEDs available
20. e example the port USB Serial Config COM3 was assigned to the module Therefore select from the list COMG and press OK Attention If you do not know the COM port you have connected the module please open Device Manager and read the chapter Selection of COM port GTGPS software SERA www topkodas lt 13 Serial Port Setup Fig 16 Upon setting COM port information of the module should be read out Go to File Read Device or press Read Configuration icon Fig 17 SERA GTauto configuration File Edit Setup Devices Update Help ETT ajaj al 2 GTauto Configuration Read Configuration Fig 17 Read Configuration icon SERA Glauto configuration File Edit Setup Devices Update Help Send Confi guration zal x alm ea alaf e GTauto Configuration Fig 18 Send Configuration icon 5 1 Content of the module configuration Options z GP Settings Z 5 Communications GSM Remote Control Fig 19 Configuration content is available at the side of the screen To open configuration window according to selected content menu click preferred part of the content GTGPS software SERA www topkodas lt 14 5 2 Main Window of the software SERA System options Main Window System Option of the software SERA is displayed in Fig Fig 20 This Window is displayed automatically when the GTGPS device is selected Devices gt GTGPS v1 It also may be selected from the content
21. epeated each 0 5 seconds If after expiry of delay time all zones remains unalarmed the system turns into ARM state along with conformation beep ARM State state of alarm system ARM DISARM For light indication may be used When the output is set for operation in pulsating mode this feature may be used to close car windows or roof ventilation Impulse time should be set 20 30 seconds When the security system will be turn on the output will generate signal to close windows Inputs OK if any of zones is disturbed the output will be alarmed This feature is usually used for indication whether all zones are in order Light Flash used for connection of light signal Upon alarm of the security system the light starts blinking Lights will also blink when activating deactivating the security system This feature may be applied to connect car direction signals It is time in seconds which indicates duration of impulse when Pulse type is being selected in the column State Mode checked the output will work as inverted Output commutation type see Fig 26 Pulse the output will work in single pulse mode Pulse time seconds should be set in Out pulse time column Steady output will work on the steady level till the next commutation 21 5 6 Window Inputs In order to open Window Inputs it is necessary to select Inputs option input parameters are being described in this window
22. hen this temperature 24 Input 1 Input 2 Input 3 Input 4 Input 5 Input amp Battery Temperature Luggage opened Bonnet opened Door opened Microwave alarm Ignition ON siren ON Low Batery Low Temperature Lock Unlock Blocking condition 1 Input 2 Input 3 Input 4 Input 5 Input amp Battery Temperature 100 Luggage opened Bonnet opened Door opened Microwave alarm Ignition ON Siren ON Low Batery Low Temperature will be reached 9 zone will be restored Additional Calibration by changing X and Y coefficients which influence temperature calculation formula it is possible to calibrate temperature showings Attention In order to change temperature scale C F go to Main Window select preferred temperature scale Temperature and after this change send configuration into the module Write Device Luggage closed v NO Bonnet closed NO Door closed NO MicrowaveRestore Iv a HO Ignition OFF NC Siren OFF Iv NC Batery restore M Nc Temp restore v NC k GTGPS software SERA www topkodas lt Luggage closed v Bonnet closed Iv NO Door closed Iv NO MicrowaveRestore NO Ignition OFF NC Siren OFF Iv NC Batery restore e HC Temp restore Iv NC k Fig 32 25 Input 1 Luggage opened Luggage closed T v NO 2 Input 2 Bonnet opened Bonnet closed m Iv NO
23. is incorrect SMS messaging may be impossible This number may be changed after inserting SIM card into any mobile phone System voltage power supply voltage the module is connected to Nearby number is value of ADC voltage When multiplying this number by the coefficient available in INS window Fig 33 voltage value V will be achieved Temperature Temperature of temperature sensor The number nearby is temperature ADC value used to calculate temperature according to the formula Temperature X ADC Y X and Y coefficients may be changed in temperature window in order to additionally calibrate temperature measuring These coefficients see Fig 34 After performing additional calibration it is possible to achieve precise temperature measurement System State nmm Indication that at the moment the module is in ARM mode mode WAITING ARM Latitude Longitude Altitude Test time Speed Speed of GPS receiver movement PDOP Position dilution of precision the term to specify the satellite layout on GPS precision in real time This is the coefficient which 1s shown on the receiver s screen thus providing information on accuracy of carried out works If the coefficient 1s small work conditions are 1deal and measurement bias is minimal and if the coefficient is big it is recommended to wait for the better satellite layout If registered PDOP 15 too big the receiver will simply not to allow performing necessary jobs When measuring u
24. isplayed table and press 8 Open Close m Save Ctrl 5 Save 45 Write Device Exil Fig 39 File Setup Devices Update Help Open Close m Save Ctrl 5 Tl Read Device Write Device Exit SERA GTauto configuration File Edit Setup Devices Update Help gluria eje sm el GTauto Configuration Fig 41 7 Installing of saved configuration into the module GTGPS In order to start saved configuration ES to File gt Open Fig 42 or press Open iconFig 43 File Setup Devices Update Help mi Save Ctrl 5 Save Read Device Write Device Exit Fig 42 GTGPS software SERA www topkodas lt 32 SERA Glauto configuration File Edit Setup Devices Update Help ea alal el GTauto Configuration Fig 43 Open X Chro Close m Save Ctrl 5 Save 45 Read Device Fig 44 Click the file of saved configuration or press Open in displayed Window Now all parameters of saved configuration have been loaded into application SERA If no any other changes are necessary press File gt Write Device Fig 44 in order to send this configuration into the module 8 Updating of GTGPS software version The latest software version may be found www topkodas lt If a version of your module is older please update it to find out the version of your GTGPS software version
25. nder 1 3 PDOP coefficient value measuring bias will be minimal Accordingly VDOP vertical accuracy PDOP VDOP HDOP GSM info HDOP horizontal accuracy GPS receiver s state whether communication is available The following conditions are possible e Not Fixed No communication Fix Quality e Fixed GPS S communication fixed e Dgps Fixed GGPS communication is fixed e Unknown Status status unknown GPS communication type e Not Fixed No communication e 2D 3D Sat Used Number of satellites used to calculate GPS coordinates setting Sat in View General number of visible satellites Showings of measured distance from geofence zone till the centre of the module Mi Eon Pressing this button starts testing of the module testing mode M non Pressing this button stops testing of the module testing mode GPS Mode Geofence Dist UJ GTGPS software SERA www topkodas lt l 6 Saving of GTGPS module configuration into PC After configuration of the module all settings may be saved at PC It enables to save time when next time the same configuration will be used it will not be necessary again to set the same parameters If you want to save that is already recorded by the module firstly you must read configuration of the module File gt Read Device see Fig 39 In order to save configuration go to File Save As Fig 40 or press icon Save icon Fig 41 Enter configuration parameter in the d
26. odas lt Found Mew Hardware Wizard Select the device driver you want to install for this hardware i Select the manufacturer and model of your hardware device and then click Next IF you FRA have a disk that contains the driver you want to install click Have Disk Iw Show compatible hardware Model USB Serial Config i This driver is not digitally signed Have Disk Tell me why driver signing is important lt Back Cancel Press Next Hardware Installation AN The software you installing for this hardware USB Seral Contig has not passed Windows Logo testing to verify its compatibility with Windows XP Lell me why this testing i important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway Press Continue Anyway GTGPS software SERA www topkodas lt Found Mew Hardware Wizard Please wait while the wizard installs the software E USB Serial Config usbser sus To CAWINOOMWS Sustema3z DRIVERS Completing the Found New Hardware Wizard The wizard has finished installing the software Far USB Serial Converter Click Finish to clase the wizard Fig 8 Displayed Window fig 8 means that your P
27. of the module System Options GSM Alarm Pager GPS tracker AVL Installer password 6 symbols xxktikik User password 6 symbols m h Reset test counter after arming ardvare details Hv GTMsPsboot_1v SA GTOPS v1 101008 M Siren signal on AEMDISARM Test time LockUnlock Mode 1 Pulse using Lock and Unlock inputs v Entry Delay B Exit Delay ho siren time 120 Temperature cecius v Auto re amp 4RM Explanation of fields of Main Window Installer password User password Reset test counter after ARMing Lock Unlock GTGPS software SERA www topkodas lt Iw Indication an aff energy saving PC time 2010 10 08 22 04 48 Fig 20 It is installer password comprised of 6 symbols when the module is being configured via SMS messages See INST codes table It is installer password comprised of 6 symbols each time the module is being controlled via SMS messages See USER code table Time period to inform how much time it will take to send informative SMS message to a user Discretion of test setting time is one hour If a check box nearby this note will be checked time of sending informative SMS message will be calculated from the beginning each time after security system is in ARM mode When connecting the module to the central lock it is necessary to set signals the module will enter ARM DISARM modes 5 versions is possible e Disable programmabl
28. ons Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed i Search removable media floppy CD AOM include this location in the search Em arbas MaT4 Browse Choose this option to select the device driver from list Windows does not guarantee that the driver vau choose will be the best match for pour hardware lt Back Cancel Fig 7 In the displayed Window fig 7 select Don t search I will choose the driver to install Press Next gt GTGPS software SERA www topkodas lt Found Mew Hardware Wizard Select the device driver you want to install for this hardware Select the manufacturer and model of your hardware device and then click Next IF you have a disk that contains the driver you want to install click Have Disk M Show compatible hardware USB Serial Contig ity This driver is not digitally signed Have Disk Tell me why driver signing iz important lt Back Cancel Press Have Disk button Look in Disk F Fi per dusbser x86 xB4 inf Recent Documents Deskto p 2 My Documents PE h tj s Es Geen File name usbser x86 dint Places Files of type Setup Information Cancel E Select driver file Windows XP usbser inf Windows 7 x86 or x64 usbser x86 x64 inf GTGPS software SERA www topk
29. rent hardware configurations Hardware Profiles Fig 9 Select Device Manager from the tab Hardware Window Fig 10 will be displayed GTGPS software SERA www topkodas lt 10 i Device Manager File Action View Help 4 amp emg LA 3 Computer Se Disk drives B Display adapters us DYDICD ROM drives 44 Floppy disk controllers Human Interface Devices 43 IDE ATASATAPT controllers 5 gt Keyboards 1 Mice and other pointing devices Monitors FJ Network adapters 7 Ports COM amp LPT m Processors Lc SCSI and RAID controllers System devices Sound video and game controllers Universal Serial Bus controllers 0 0 E m H Fig 10 In Device Manager Window click symbol near Ports COM amp LPT in order to scroll Ports COM amp LPT menu If the module is powered with 12V and it is connected to the PC via USB port thus upon scrolling Ports COM amp LPT Window Fig 11 will be displayed Attention If the module GTGPS is not powered with 12V and it is not connected to the PC via USB interface menu Ports COM amp LEDI item USB Serial Port will not be visible 1 File Action View v EE 12115 Eg HP EF Acronis Devices 2 Batteries 2 Biometric Devices Computer Disk drives amp Display adapters DVD CD ROM drives is Human Interface Devices as ID
30. rm verSpeed Alarm e Fig 36 Explanation of fields of Service text summary Window Name of Status Event Event Text Event test which may be changed Send If the check box is checked the message about a certain event will be sent to a user if it is configured in Communications window GTGPS software SERA www topkodas lt 28 5 8 Window Text summary In order to open Text summary Window select Text table Fig 36 from the left side of the Window This Window is intended for creation of equivalents ID 1 Events Event 2 GSM Signal strength Signal strength 3 Module voltage System voltage 4 Output state Output states 5 New password New password 6 System state System info Fig 37 Explanation of fields of Text summary Window PI Tener 0 0 Text in English Text Equivalent of the text available in Text which may be changed Words available in this field will comprise messages being sent GTGPS software SERA www topkodas lt 29 59 Window Testing and Diagnostic window In order to open Testing and Diagnostic window select Testing and Diagnostic option This Window is intended for testing of the module for operation analysis and diagnostics This feature is very convenient when installing the module Outi OnOff IMEI 356895030001 T99 Out2 On Off 5 READY Registration Registered home network ve 1 vM IN2 v IN3 M IN4
31. tage pulse Mode 6 Mode 6 V gt 500ms Pulse Lock input similar as 5 mode only inverted Boot start up program version BOOT This part of the program is able to update Firmware SW SW Firmware version of the module GTGPS software SERA www topkodas lt 16 Button Reset Module will reset the module as programmed This function operates similarly as actual built in RESET module If this function will not operate in the event USB Serial Port is not open or FW program of the module is not functioning properly GTGPS software SERA www topkodas lt 17 5 33 Window GSM communication options In order to open Window GSM SMS and DIAL communication options it is necessary to select Communication clause Fig 19 from the left side The Window Fig 21 including user table whom GSM SMS messages are being sent and calls are being made User number up to 16 Double click on the selected line will show selected user window Fig 22to set what events should be sent to the specified number User numbers should be entered with international code Near the telephone number of each user check boxes which events will be sent to that user SM SMS and communication optiona USER 1 Communication Settings X Please note that all phone numbers must start with USER Phone Number a country code area 37045242822 code phone For example Please note that all phone numbers must start with a country code are
32. to install to a different Folder Install SERA configuration program to C Program Filesttopkodas SERA Fig 2 Installation directory will be displayed in the Window Fig 2 fig 2 If installation directory of the software is OK press Next If you would like to install the software in the other directory press Change specify other installation directory and then press Next gt i SERA configuration program InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation IF au want to review or change any of your installation settings click Back Click Cancel to exit the wizard Current Settings Setup Destination Folder C Program Filesitopkadas SER A User Information Mame D Company Install Cancel Fig 3 Check if the correct data are entered and press Install in the displayed Window Fig 3 Fig 3 GTGPS software SERA www topkodas lt ie SERA configuration program InstallShield Wizard InstallShield Wizard Completed The Installshield Wizard has successfully installed SERA configuration program Click Finish to exit Ehe wizard Cancel Fig 4 After successful installation of the software SERA press Finish in the displayed Window Fig 4 fig 4 Congratulations you have successfully installed the application SERA in your PC 2 USB drivers installation In order to configure GTGPS via USB interface it is necessary to install USB DRI
33. v INS Outs On Off x i 4 ING IN7 I outa Sao SMS Service Come Address 69899992 14 Ng Longitude 904758 GPS Mode Altitude 12411 satused 7 D 10 10 2010 18 03 09 o 0kmin Geofence Dist 0 05km 2 20 2 10 1 20 Fig 38 Explanation of fields of Testing Window IN2 This is alarm indication of each of eight inputs Checked check box nearby the appropriate input means that the said input zone INS was activated Number near each input is a coefficient indicating IN6 input voltage IN7 INS Lock Input indication Number nearby is a coefficient indicating input voltage Unlock Input indication Number nearby is a coefficient indicating input voltage Outputs states Checked box nearby the appropriate output means that this output is active By pressing buttons on off output states are controlled It is convenient to use when it is necessary to test outputs operation GSM info IMEI number of GSM modem available in the module If note READY is visible it means that SIM card is fully functioning Otherwise check whether PIN code request is off or replace SIM card Signal level Signal strength of GSM communication Registration State of GSM modem registration to GSM network 30 GTGPS software SERA www topkodas lt SMS Service Centre SMS centre number This number should be checked if it correct Address If this number
34. z Testing and Diagnostic Mode 1 C Pulse using Lack and Unlock inputs At GTGPZ v1 101008 Entry Delay s Z Exit Delay f 0 Siren time f 40 v Siren signal on ARM DISARM celcius ATESTA w Indication on off energy saving FC time 2010 10 08 22 24 48 COMMS is closed Firmware file have been loaded Please connect and reset your hardware COM3 is closed Firmware file have been loaded Please connect and reset your hardware COMS is opened i Crna po elase th See user manuals For details COM3 Disconnected GTGPS v1 101008 EE When updating of firmware will be finished the system will displayed the table below x n Update successful Reset module to continue Then press RESET button Then press OK GTGPS software SERA www topkodas lt 34 Read configuration of the module File gt Read Device Go to Main Window Check whether the firmware has been updated SW xxxxxxxxx ardware details GTGPS GTIGPShbaot 1v GDIGPS v1 101008 Programme version is also visible below CON Disconnected GTGPS vi 101009 E GTGPS software SERA www topkodas lt 35

Download Pdf Manuals

image

Related Search

Related Contents

SciCan Data Logger  Réservations Mode d`emploi    FR-Notice système GH 2008  Manual del Usuario, Membrana Interna tipo Pontones de  EntreMatic EMSL USER'S MANUAL  Braun 5761 Electric Shaver User Manual  Apri - Documentazione tecnica  Siemens Acuson X300 Knobology Guide  MODE D`EMPLOI ET D`INSTALLATION  

Copyright © All rights reserved.
Failed to retrieve file