STEYR Control Center Configuration User Manual

image

Contents

1. e Empty sensor place When Empty sensor place is selected then the corresponding sensor place in the O Box view of the SCC software is empty This is needed when the sensor place on the O Box connector is not used Z001075 0 06 130716_SMO AS Page 28 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q e Fuel sensor Fuel level sensor for tanks Sensors of this type can be selected as used tank sensor in the tank view of the SCC software e Temperature senor Temperature sensors e Pressure sensors Pressure sensors e Digital sensors Digital sensors are sensors which have only two states on and off like a switch The only thing you can configure with a digital sensors Is a high alarm warning when the switch is closed null ohm or a low alarm warning when the switch is opened ohm Predefined digital sensor Screen off mode If this sensor is selected and the corresponding sensor switch is closed then the display backlight of the SCC is switched off When the sensor switch is opened the backlight is turned on again e Common sensor Sensors with no special type Calibration values Calibration values are necessary to define non linear sensors When defining sensors without any calibration values then the scale value is calculated with the linear interpolation method between the sensor min and max value Calibration values are always two values the resistance value of the sens
2. BP amp STEYR CONTROL CENTER FM Sensors of Fuel AFT amp e O Box of G PRESS AG TEMP fi BILGE ALARM gt Relay output o He TiO Box Mo 4 MC england K Sensor input EES Connected SCC e Default 1 0 Box Via ActiveSync connected SCC EME T Boxes Fe Holyhead HA Plymouth Picture 2 route window Under the main element STEYR Control Centers it s possible to create grouping folders and STEYR CONTROL CENTERs Grouping folders are useful to get a structure in the configured SCCs Use these folders for example for customers a boat configuration places The second main element Connected SCC is only available if an SCC Is connected via ActiveSync to the computer this has the same functionality as an SCC which is stored in the pool Z001075 0 06 130716_SMO AS Page 16 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q How to work with the application STEYR CONTROL CENTER pool The SCC pool is a directory on the hard drive or a mounted network share The pool consists of grouping folders and configured STEYR CONTROL CENTERS Grouping folders can contain other grouping folders STEYR CONTROL CENTERs or both By default the directory for the SCC pool is SCCPool under the installation path of the SCCWinConfig software You can change the SCC pool directory with the menu item Options gt Set path of SCC pool What is configurable of a STEYR CONTROL CENTER Time zone Gear
3. g with menu File gt Save before quitting the application or disconnecting the SCC from ActiveSync After saving you must restart the STEYR CONTROL CENTER to take effect of the new settings If you do not save the changed data and disconnect the SCC from ActiveSync or quit the application all changes will be lost Z001075 0 06 130716_SMO AS Page 18 of 33 sTEYRMOTORS Q STEYR CONTROL CENTER Configuration software users manual Configure STEYR CONTROL CENTERS Adding a new grouping folder Right click the STEYR CONTROL CENTERs element or another grouping folder in the route window in the following context menu select New Folder and input a name for it Adding a new STEYR CONTROL CENTER Right click the STEYR CONTROL CENTERS element or a grouping folder in the route window in the following context menu select New STEYR CONTROL CENTER and input a name for it After confirming the Enter name input box with OK the new SCC will be added with default configuration settings j STEYR Control Center Configuration _ Of x Fie Options View Help STEYR Control Centers H austria HA boot xy Be england H birmingham STEYR Control Center Configuration EYRMOTORS GmbH Steyr Austria a london i New Folder New STEYR Control Center Paste STEYR Gontral Genter Delete Folder Rename Folder Create anew STEYR Control Center NUM E Picture 3 create a new SCC Z001075 0 06 130716_
4. ratio Propeller pitch Volume and alarm level of manual tank Unit values CAN behaviour Default O Box O Boxes Handling with the user interface Creating deleting renaming copying or transferring objects grouping folders SCCs O Boxes outputs or sensors is done over the context menu when clicking with the right mouse button on an element in the route window When adding an object the object is always added as a sub element from the selected element in the route window To change data of an object SCCs O Boxes outputs or sensors select the corresponding element in the route window After this all configurable data are shown in the data window Important when entering fraction of numbers always use the decimal point e g 15 7 Z001075 0 06 130716_SMO AS Page 17 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Saving changed data in the SCC pool After changes have been made the data must be saved e g with menu File gt Save before quitting the application to store the changes permanently in the pool Some changes are stored immediately in the pool without the need to save them explicitly these are e renaming a grouping folder or SCC e deleting a grouping folder or SCC e creating a new grouping folder or SCC e copying an SCC Saving changed data of the Connected SCC Each change is done temporary on the hard drive so you have to save your work e
5. Configure STE VR CONTROL CEN VERS vacoccisicsviascsacarswsivecisnssxctesvsivectarstsainsveisewsanseeeiacoekeeelasseons 19 Adding a new grouping folder sseesesseoseccccsecsccecccccccesecscecocseoscecocseosccecccecsececscesocseosccossccescecscecesseossecoss 19 Adding a new STEYR CONTROL CENTER seeecssecccssscccssceccssceccsececosecccssecccsececcsececssecccssseecsssecssseso 19 Configure a STEYR CONTROL CENTER sssnsssessenssersssrsssersserssersserssersseroserossesssresserssersseesseroseeeseersserssersseens 20 Configurable common SCC Ga a vescsccuiccsvecssnerscasgnseh nantenuncdniash toartsaneiedetibeantearseceaesbioewieosseindeeriocaottagiadetsieentacnaae 20 Elements below an SCC element in the route window cccecccccneececceeeceeeeeeeeeeeeeeeeseeeeeeseeeeeeseeeeeeseeeeeaeeeeeeeaes 21 Adding a new I O Box to a STEYR CONTROL CENTER 0 sesssscccccssssscccccccssscccscessssscsees 22 Cona STS Oo acaroecsesten econ e E E I E O E E A N 22 Comicura ble common VO Box dila esossseeso asnoisan EDE EEO OE aO O S ao 23 Elements below an I O Box element in the route window ssssessseesssseessserssseresseeessserssseresseresseeesseeresseresseee 23 Z001075 0 06 130716_SMO AS Page 2 of 33 STEYR CONTROL CENTER STEYRMOTORS sacle Configuration software users manual Addins anew oulpan Dy OS ON ssisiiiiriiiiniiiininn ini kn i ios i hi h i hs iSi En S A R E R AN nn n ni n i ais 24 CN UT A OU AA ir a a a E AR Naneeesa
6. ER is connected to the host computer via ActiveSync you see the element Connected 5CC jn the route window You can configure the connected SCC like a normal SCC which is saved in the pool When you are finished with the configuration don t forget to save menu File gt Save your work When disconnecting the SCC from the host computer without saving you will lose all your configuration changes After saving changes of the connected SCC you have to perform a restart of the SCC to take effect the new configuration Transfer the configuration of an SCC in the pool onto the connected SCC After you have finished the configuration of SCCs in the SCC pool you may want to transfer the settings from an SCC inside the pool onto the connected SCC This is easily done by selecting with the right mouse button on the relevant SCC in the pool and selecting in the following context menu Transfer STEYR CONTROL CENTER The entry Transfer STEYR CONTROL CENTER is only available if an SCC is connected to the host computer via ActiveSync Ji STEYR Control Center Configuration Fie Options View Help File Options View Help OY STEYR Control Center Configuration STEYR Control Centers H austria o BAA boot xy a E Default 1 O Box FM TfO Boxes Time zone uT Copy STEYR Control Center Delete STEYR Control Center Gear ratio Rename STEYR Control Center H E O Box Mo 3 4 Outputs Propellor pitch Transfer STEYR C
7. File Options wiew Help STEYR Control Centers B austria Serial number 200004 E zat boot xy H E Default I 0 Box i o EHO yo Boxes Priority mm Picture 7 configurable data of an O Box When selecting an O Box in the route window you can configure data as shown in the above picture Z001075 0 06 130716_SMO AS Page 22 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Configurable common I O Box data e Serial number serial number of the O Box for which this configuration Is valid This number is very important because the STEYR CONTROL CENTER recognizes the connected O Boxes through there serial numbers According to the serial number the SCC knows which configuration it should take to calculate and show data from the O Box The configuration of an O Box is always stored on the SCC and not in the O Box itself The only thing which is permanently programmed into the O Box is its serial number Allowed values any positive integer except zero e Priority when more than one O Box is connected to the STEYR CONTROL CENTER the priority defines the order of the recognized O Boxes in the O Box view of the SCC software Null means the highest priority and 255 the lowest The order is random if two ore more O Boxes have the same priority Allowed values any slider position Elements below an I O Box element in the route window a STEYR Control Center Confi
8. O AS Page 14 of 33 STEYR CONTROL CENTER Configuration software users manual Application menu Menu File e Save Ctril S saves all changes onto the hard drive if data in the SCC pool are changed or transfers changes to the jii STEYR Control Center Fie Options View Help connected SCC if changes were made on the connected SCC Save Cbrl 5 Exit quits the application if changes were made the application will ask to save them Exit menu Pron 1i h h h h J STEYR Control Center Configu e Set path of a pool sets t as ore gh e re Fie Options view Help drive where all SCC and grouping folders shou e ae ae saved Menu View STEYR Control Center Confi e Toolbar shows or hides the toolbar File Options view Help e Status Bar shows or hides the status bar Toolbar w Status Bar Menu Help a ii STEYR Control Center Configuration e About SCCWinConfig shows version information Fie options view fee About SCEWinConfig Toolbar e fy sameas menu File gt Save Z001075 0 06 130716_SMO AS Page 15 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Route window 10 AAE 3 EG am austria symbols Ef boat xy DES i Default 1C Box H Vo Boxes E Main element for the STEYR CONTROL El I 0 Box Mo 3 CENTER Pool HES Outputs ioe gt MAY LT i E Grouping folder 2l gt ER EP 7 3 JET
9. SMO AS Page 19 of 33 STEYR CONTROL CENTER STEYRMOTORS aCe ee Pat Configuration software users manual Configure a STEYR CONTROL CENTER J STEYR Control Center Configuration O xl File Options wiew Help 4 STEYR Control Centers MES austria o EA boat xy Se england Time zone UTC 2 Hours Manual tank litre AS birmingham Gear ratio oO EES london Tank volume AY Propellor pitch 0 i oe A Alarm level 1 o HE EE a manchester H Connected SCC Temperature Pressure volume kmh i Celsius C Bar Litre C knots Fahrenheit F C PSI Gallons mph C kPa CAN behavior i Master C Slave Picture 4 configurable data of an SCC When selecting an SCC in the route window you can configure data as shown in the above picture Configurable common SCC data e Time zone when a GPS sensor is connected to the STEYR CONTROL CENTER then the time zone must be configured because the received GPS time is UTC time Allowed values all values from the drop down list e Gear ratio to calculate the theoretical soeed and the corresponding slip value this value is required i e 2 1 Allowed values any positive decimal number e Propeller pitch this value is needed for the same reason as the gear ratio Allowed values any positive decimal number i e 20 e Tank volume tank volume of the manual tank Allowed values any positive integer e Alarm
10. STEYR CONTROL CENTER Configuration software users manual ay STEYR Control Center Configuration iol x File Options wiew Help c a e Centers G2 austria Bi boot oe Bg a STEYR CONTROL CENTER Configuration L Eh TO Boxes 10 Box No 3 ED Outputs c STEYRMOTORS GmbH Steyr Austria ES Sensors K BILGE ALARM o ca TfO Box No 4 AMC england EES Connected cc fe Default 1O Box Fl O Boxes Holyhead Se Gutpuks g Plymouth Z001075 0 06 130716_SMO AS Page 1 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q ADDCO ON aE E EE EEE E EEE EE EE E 4 DNOU OI EEE E E EEE EEA ET EE E EE EEA EE 4 DSU AON OEO OA A ONE 5 Microsoft ActiveSync for Windows XP and earlier Windows Versions sescsseeccsseccssseccsseecosseeoose 5 STEYR CONTROL CENTER Configuration Software ssescssseccsscecssecccssecccssceccoscecssecccssecccsseeccsseeoo 5 Connec ed SOC DIS DIY area eian EENE ETE EENE EEN EER 6 Connected SCC Application earlier than v1 22 eccssecccssseccsseeccsececssecccssecccssecccsececssecccssecccsseeccsseesseee 6 Connected SCC Application v1 22 sssseccssccccsscccssecocssecccssceccssceccsececssececssecccsseccssseessececssececsseecssseecsssee 7 Connected SCC Application v1 23 or latter eesssececssscccssseccssceccsececsseccccsecccssecccsececssececsecccsseeccsseecsssee 8 AlertList AlertList SE and Engine List ccccssscc
11. ahrenheit F C PSI C Gallons C mph kPa CAN behavior Battery Visualization Master 12 Battery 0 Slave C 24 Y Battery C automatically detection f do not show New is as at the SCC Version v1 22 the display of the serial number of the connected device on the right side and the software version number as well as the version number of Engine List engine_list_v2 xml and Alert List alert_list_v2 xml Furthermore the version number of Alert List SE alert_list_v2_SE xml is shown Z001075 0 06 130716_SMO AS Page 8 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q What is more you have the possibility to configure the battery display at the SCC There are four different possibilities to choose e 12 V Battery The batterydisplay is now adjusted for a 12 battery This is the default value and works as the versions v1 22 and earlier e 24V Battery The battery display is now adjusted for a 24V Battery e automatic detection Depending on the applied voltage the range switches automatically between 12V and 24V Battery Z001075 0 06 130716_SMO AS Page 9 of 33 e donot show The Battery display is not shown Z001075 0 06 130716_SMO AS Page 10 of 33 STEYR CONTROL CENTER Configuration software users manual AlertList AlertList SE and EngineList Connected SCC Application V1 22 or latter When saving the Configuration AlertList and EngineList are copied fro
12. ation of the SCCs can be changed and stored in the STEYR CONTROL CENTER Pool on the hard drive or it s possible to configure directly a via Active Sync to the host computer connected SCC For archive or duplicate purpose you can copy the whole configuration of a connected SCC into the STEYR CONTROL CENTER Pool The configuration of stored or changed SCCs in the STEYR CONTROL CENTER Pool can be transferred to the connected SCC Z001075 0 06 130716_SMO AS Page 4 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Installation Microsoft ActiveSync for Windows XP and earlier Windows Versions Mobile Device Manager for Windows Vista Windows 7 and later Windows Versions You need to install Microsoft ActiveSync or Mobile Device Manager to connect a STEYR CONTROL CENTER to the computer This is necessary to access and change data from an SCC If ActiveSync or Mobile Device Manager is already installed on the computer and a connection to an SCC is possible then you don t have to install ActiveSync or Mobile Device Manager again How to check if a connection via ActiveSync Mobile Device Manager between an SCC and the computer is possible In the ActiveSync connection settings enable the USB connections power up the SCC and connect it with the USB cable to a free USB port of the computer The connection wil be established automatically Confirm the question if you want to set up a partnership with th
13. e device with no a guest connection is enough to configure the SCC STEYR CONTROL CENTER Configuration Software For installation simply run the setup program InstallSCCWinConfig msi from the setup CD or download the newest version from the internet ATTENTION uninstall any previous installed version before installing a new one Z001075 0 06 130716_SMO AS Page 5 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Connected SCC Display The shown dialog varies between the SCC Applications Version of the connected device Connected SCC Application earlier than v1 22 If you connect with an application earlier than 1 22 the dialog looks as follows gi STEYR Control Center Configuration File Options View Help al Ea STEYR Control Centers i gt Time zone UTC 2 Hours 451456 es ae Manual tank litre AS jhuioi i Gear ratio lo r s 1 19 DES Connected SCC Tank volume 800 SCC Application Propellor pitch lo i Alarm level 75 Units Speed Temperature Pressure Volume kmh Celsius C Bar Litre 0 Knots C Fahrenheit F C PSI Gallons C mph C kPa CAN behavior x Master Slave New is the display of the serial number of the connected device on the right side and the software version number Z001075 0 06 130716_SMO AS Page 6 of 33 STEYR CONTROL CENTER Configuration software users manual Connected SCC Application v1 22 If you connect
14. ftware is a push button That means that an output is only switched on when the button is pressed in the SCC software When Push button is not checked the output is like a normal switch Z001075 0 06 130716_SMO AS Page 25 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q E O Box No 3 Changing the position of an output ee ee P am Right click the output element in the route window from which you want change the position in the following context menu PORE Copy Output select Move up or Move Down Repeat this step until the ii output is placed correctly AR BILGE a 1 0 Box No 4 The top position is the top left button in the STEYR CONTROL CENTER one below top is for top right button 3 from top is bottom left and bottom position is the bottom right button on the display Renaming an output Right click the output element in the route window of which you want change the name in the following context menu select Rename output The name of an output is equal to the label of the corresponding button in the SCC software Adding a new sensor to an I O Box ay STEYR Control Center Configuration Fie Options View Help STEYR Control Centers H austria Fr aren TO Box S T Y R 2 a TO Boxes EE 1 O Box Na 3 EC Outputs c STEY B Right click the Sensors folder of the O Box where you want add a new sensor in the route window in the f
15. guration i O x File Options View Help a STEYR Control Centers H austria eat book xy A Default 1 0 Box EM 0 Boxes O Out puts AS Sensors A Fuel AFT fa G PRESS f G TEMP BILGE ALARM fe 1 0 Box No 4 H england Serial number a Priority O Picture 8 elements of an O Box Z001075 0 06 130716_SMO AS Page 23 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q e Outputs The Outputs folder contains the configured relay outputs of an O Box The order of the outputs in the route window Is important because it represents the pinning on the O Box output connector The first output in the route is the first relay place on the output connector Pin 1 and Pin 12 of the O Box the second output is the second relay place etc for a connector description of the O Box see the SCC technical documentation e Sensors The Sensors folder contains the configured sensor inputs of an O Box The order of the sensors in the route window Is important because it represents the pinning on the O Box sensor connector The first sensor in the route is the first sensor input place on the sensor connector Pin 1 and Pin 8 of the O Box the second sensor is the second sensor input place etc for a connector description of the O Box see the SCC technical documentation Adding a new output to an I O Box j STEYR Control Center Co
16. l Transferring of a saved SCC Configuration Before a saved SCC Configuration is transferred to a connected SCC it is checked if version numbers of the scc_config xml are identical If not the transfer is stopped with the following error code S CCWinConfig The stored configuration can not be copied to the device The version of the configuration File is incompatible Stored configuration version 2 Configuration version on the device 1 This ensures that no configuration of a SCC with an application 1 23 is saved to a SCC with an application 1 22 or vice versa Z001075 0 06 130716_SMO AS Page 12 of 33 STEYR CONTROL CENTER Configuration software users manual Version Display SCCWinConfig The About Dialog of the SCCWinConfig shows now the version numbers off all the in the setup saved XML files About SCC WinConfig SccwincConfig Version v1 15 Copyright C 2006 2013 Predefined alert list version A 1 00 3 Predefined alert list 5E version 2 55 3 D Predefined engine list wersion 3 1022 F Predefined default 1O box wersion 1 Predefined sensor list version H 31 The version numbers match the following tags A m_iContentVersion default alert_list_v2 xml m_iVersion default alert_list_v2 xml m_iContentVersion default alert_list_v2_SE xml m_iVersion default alert_list_v2_SE xml m_iContentVersion default engine_list_v2 xml m_iVersion default engine_list_v2 xml m_iVersion default iob
17. level level when the SCC should show a warning if the actual contents of the manual tank falls below this threshold Z001075 0 06 130716_SMO AS Page 20 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Allowed values any positive integer and 1 If 1 then no alarm level is configured e Units unit which is shown for speed temperature pressure or volume values in the SCC software Allowed values any selection e CAN behaviour it is possible to connect more than one SCC on the same CAN line at different places e g to view engine or sensor data or to switch an O Box relay output from different locations on a boat At start up the Master SCC initializes the O Boxes and Slave SCCs with important values for the CAN communication and this is only allowed from just one Master SCC So for a functional communication between the engine SCCs and O Boxes it s necessary to have just one Master SCC and any number zero is also possible of Slave SCCs Allowed values see description above Elements below an SCC element in the route window ai STEYR Control Center Configuration File Options View Help Time zone UTC 2 Hours Lio Boxes Manual tank litre lt 2 ey BOY Gear ratio 2 0 E outputs Tank volume 100 HORT Propellor pitch el Alarm level 10 3 T Picture 5 elements below SCC element e Default I O Box Each SCC has a Default O Box
18. m the PC to the SCC With the SCCWinConfig V1 15 the version numbers of AlertList and EngineList installed on the SCC and installed on the PC are compared Only if the files on the PC have a more recent version number they are transferred to the SCC If this is not the case the files are not overwritten and you get the following failure code SCC WinContig Copy File c SOURCESCCWinConFig Debug deraultengine_list_v2 xml to STEYR Control Center Failed There is a newer version of the File on the STEYR Control Center File version on PC 1 01 f2 File Version on STEYR Control Center 1 02 f z If the connected SCC is a version 1 23 or later the stated as above procedure is the same for Alert List SE At Version 1 22 the AlertList SE is not transferred Connected SCC Application earlier than V1 22 From the on the PC saved files engine_list_v2 xml and alert_list_v2 xml the files engine_list xml and alert_list xml are generated The version number is set according to the SCC Application and all to SCC Application unknown records m_iContentVersion and at SCC Application 1 19 m_bShowPopUp are deleted The now produced files are transferred to the SCC Due to the missing m_iContenVersion it is not save to say that a newer Version is not overwritten by an older one This behaviour is identical with the former version of the SCCWinConfig Z001075 0 06 130716_SMO AS Page 11 of 33 STEYR CONTROL CENTER Configuration software users manua
19. member which can be configured like a normal O Box except for the serial number This configuration will be used if an SCC recognizes a new or unknown O Box SCC s recognize the O Boxes by there serial number Recommended configuration when using only one O Box configure the Default O Box equal to the connected one The advantage is when you change the O Box due to a defect you don t have to set up the new one e O Boxes The O Boxes folder can contain an unlimited number of configured O Boxes which the STEYR CONTROL CENTER knows Z001075 0 06 130716_SMO AS Page 21 of 33 STEYR CONTROL CENTER Configuration software users manual Adding a new I O Box toa STEYR CONTROL CENTER STEYR Control Center Configuration File Options View Help STEYR Control Centers E JO austria XY boot x i i amp Defaut 1 0 Box S T I Y R Co n c STEYRM Picture 6 Add a new O Box H england Right click the I O Boxes folder of the STEYR CONTROL CENTER where you want add a new O Box in the route window in the following context menu select Add new O Box and input a name for it After confirming the Enter name input box with OK the new O Box will be added with default configuration settings from the Default O Box After this enter a correct serial number for the new O Box because zero is not allowed Configure a I O Box a STEYR Control Center Configuration l Ioj x
20. n alues 5 x Calibration values Cancel S900 23 000000 4300 29 000000 S40 90 000000 Move Up Insert Delete Move down Clear all Picture 14 raising resistance falling scale value Attention when defining calibration values you must always define them in the right order Z001075 0 06 130716_SMO AS Page 30 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Changing the position of a sensor EHE Sensors J G PRESS DEUE Right click the sensor element in the route window of which you want change the position in the following context menu select Move up or Move Down Repeat this step until the sensor is placed correctly Copy Sensor Delete Sensor Rename Sensor The top position is the top middle instrument in the STEYR CONTROL CENTER one below top is for the bottom left instrument 3 from top is bottom middle and bottom position is the bottom right instrument on the display Renaming a sensor Right click the sensor element in the route window of which you want change the name in the following context menu select Rename sensor The name of a sensor is equal to the label of the corresponding instrument in the SCC software Z001075 0 06 130716_SMO AS Page 31 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Working with the Connected SCC Change the connected SCC directly When a STEYR CONTROL CENT
21. nfiguration File Options View Help a STEYR Control Centers H austria Seat book xy A Default 1 0 Box 3 eS T 0 Boxes Ti0 Box No a Picture 9 Add a new output Right click the Outputs folder of the O Box where you want to add a new output in the route window in the following context menu select Add new output and enter a name for it After confirming the Enter name input box with OK the new output will be added with default configuration settings Maximally four outputs are permitted Z001075 0 06 130716_SMO AS Page 24 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Configure an output ay STEYR Control Center Configuration 0 File Options wiew Help a STEYR Control Centers H austria Auto off time 1 10 sec 0 At Default 1O Box HE 10 Boxes I 110 Box Na 3 HES Outputs T Push button 2 H E Sensors HES T0 Box No 4 H england Picture 10 configurable data of an output When selecting an output in the route window you can configure data as shown in the above picture Configurable output data e Auto off time duration after which time an active output is switched off automatically Attention the unit of this value is 1 10 seconds e g a value of 100 means ten seconds Allowed values any positive integer Zero means no automatic switch off e Push button when checked the button in the O Box view of the SCC so
22. ollowing context menu select Add new sensor and input a name for it After confirming the Enter name input box with OK the new sensor will be added with default configuration settings Maximally four sensors are permitted Z001075 0 06 130716_SMO AS Page 26 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Configure a sensor AP STEYR Control Center Configuration j g O x File Options wiew Help 4G STEYR Control Centers 4 austria i Pressure sensor Bf boot xy Sensor type BG Default 10 Box self defined sensor Sensor BO I O Boxes fi TO Box No 3 Filter 2 i e H Outputs A sensors Sensor max value 1 10 Ohri oe i Fuel AFT eG PRESS Sensor min value 1 10 Ohm 63 25 Scale unit BILGE ALARM Scale max value HE 1 O Box No 4 D jer xl AES england Scale min value I Enable upper red region l 25 Enable high alarm ae i E Engine must rum I Enable lower red region Enable low alarm in Engine must rum Calibration walues 6 value s set Lower red region Picture 12 configurable data of a sensor When selecting a sensor in the route window you can configure data as shown in the above picture Configurable sensor data e Sensor type see sensor type description below e Sensor in this drop down list you can find all predefined sensors of the selected sensor type When selecting any predefined sensor all data exce
23. ontrol Center 2 EH Sensors R Fuel AFT Pue AET Units J G PRESS oof G PRESS P fof G TEMP Speed 1 if TEMP Speed i BILGE ALARM T PE E C Kmih B I 0 Box Mo 4 C kmh r je aia BMG england knots england H Connected SCC b knots ae mph z Picture 15 Transfer to connected SCC and copy connected SCC EUER Copy connected STEYR Control Center Copying the connected SCC into the SCC pool To store the connected SCC inside the SCC pool right click the Connected SCC element in the route window and select Copy connected STEYR CONTROL CENTER Now right click a grouping folder or STEYR CONTROL CENTERS and select Paste STEYR CONTROL CENTER enter a name for the SCC and confirm the box with OK The configuration of the connected SCC is saved below the folder where you have selected Paste STEYR CONTROL CENTER Z001075 0 06 130716_SMO AS Page 32 of 33 STEYR CONTROL CENTER Configuration software users manual The About SCCWinConfig dialog To obtain version information of the application and the available predefined sensors select menu Help gt About SCCWinConfig About SCCWinConfig xX SCCWinContig version v1 05 Copyright 2 2006 Predefined sensor list version 2 Picture 16 About SCCWinConfig dialog Z001075 0 06 130716_SMO AS Page 33 of 33
24. or and the corresponding scale value This pair of values defines a point in the sensor curve A sensor can have an unlimited number of calibration values Attention when defining a calibration value pair the resistance value must be given in 1 10 ohm Z001075 0 06 130716_SMO AS Page 29 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q 2 000000 710 3 000000 900 4 000000 1070 5 000000 Ee 1240 6 000000 1400 7 000000 Insert 1560 5 000000 1630 5 500000 Delete i700 9 000000 1840 10 000000 Move down Clear all Picture 13 calibration values input dialog The order of the values listed in the calibration values dialog is very important the calibration value pair with the lowest scale value has to be at the top at the bottom of the list the value pair with the highest scale value The list is ordered from the lowest scale value to the highest scale value The lowest or highest scale value of the calibration values may not be the same as the scale min or max It s also possible to start and end with the calibration values somewhere in the middle of the sensors scale bandwidth In the picture above you see a sensor with the behaviour when the resistance of the sensors goes up the scale value goes up too There are also sensors like temperature sensors NTC s with the opposite behaviour when the resistance goes up the scale value falls see the picture bellow Calibratio
25. ox_default xml m_iContentVersion default sensors xml m_iStructVersion default sensors xml T MnmMOod Ww Previously only the version number of the Predefined sensor list version was shown This is identical with point in the new dialogue Z001075 0 06 130716_SMO AS Page 13 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Application interface Main window M enu 2 STEYR Control Center Configuration P File Options View Help Pa em ORSTEYR Control Centers Toobar B austria H boat xy a Soa pi STEYR CONTROL CENTER Configuration 7 E PA w Outputs c STEYRMOTORS GmbH Steyr Austria Sensors K Fuel AFT GPRESS I GTEMP BILGE ALARM H 1 0 Box No 4 H england El E Connected SCC H E Default 1 0 Box 5 10 Boxes EEA Holyhead E D Outputs gt ER BP gt JET BP am Sensors E L Plymouth gt NAY LT gt IR FLD Status bar Picture 1 application window Menu application menu Toolbar with the save button changes are stored in the STEYR CONTROL CENTER Pool on the hard drive or the connected SCC is updated Route window all stored SCCs and the connected SCC are listed in this area Data window depending on which item is selected in the route window all configurable values are shown in this area Status bar in this line is a short description of selected menu or context menu entries shown Z001075 0 06 130716_SM
26. pt the red region parts are filled out When selecting the self defined sensor entry from the drop down list it s possible to configure all values from the sensor yourself e Filter number of measured sensor values to calculate an average value This is useful for a sensor which has a huge fluctuation e g tank level sensors The average value is shown in the corresponding instrument in the O Box view of the SCC software The O Box measures and sends the sensor values approximately every second so a filter value from max five is recommended Allowed values any slider position Zero and one means no filter is used the sensor values are shown directly in SCC software Z001075 0 06 130716_SMO AS Page 27 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q e Sensor max value resistance of the sensor when it reaches the highest possible scale value Attention the unit of this value is 1 10 ohm e g a value of 1000 means 100 ohms Allowed values positive integer 0 65535 e Sensor min value resistance of the sensor when it reaches the lowest possible scale value Attention the unit of this value is 1 10 ohm e g a value of 1000 means 100 ohms Allowed values any positive integer 0 65535 e Scale max value value which is shown in the instrument at the end of the scale Allowed values integer 999 999 e Scale min value value which is shown in the instrument at the start of
27. ssssccccnssccccnssccccssccccnssccccssscccnssccccsscccessseceessecees 11 Connected SCC Application V1 22 or latter ssssecosseeccsseccssscccssscccsseccsssecssssecosseecssseessssecsssseessseesssee 11 Connected SCC Application earlier than V1 22 eeecsseeccssccccssceccsscecssececssceccssceccsecccssecccssecccsseecsseeeesse 11 Transferring of a saved SCC Configuration cccscccossccccsscccssscccsscccnsccccsscccscccusscccscccesscccescceess 12 Version Display SCCWinConfig s ssesessessssessseeessseosseeesseecsseccsseeosseecssecossecosseeossecosseecsseeosseeosseeoo 13 Apea Non MT ACC ee E E 14 Mant VINON rinan rrrrr rr err rrr rrrerrrereerrrrrrrrre reer rrr ere rrerrrrrr errr rrr rere 14 APPI ACTON TINO TINE cos odes a E E E E E A E 15 Koue WOY rE 16 How to work with the application vaisessterenciusdveaeraccuansiousenearcivereaxencauudevensiuntveveset sues eaiverieier es 17 SIER C CONTROLC CENTER pool osisssa ee i e ai 17 What is configurable of a STEYR CONTROL CENTER cccsssssssssccccsssscscccscssssscccscsssssscooes 17 Handhne with he user interia CE vocssicccssccccsececcsceccscesecenseccucveucenvecsusesccesssessesseccasscsususcecetsseucsensvevessuseswess 17 Savino changed data im the SCC POON wesccccccesescsssescccsvssescesssvesessssnscccssecescsssscssssssecsscsssecesesceessssevsesesievess 18 Saving changed data of the Connected SCC scsssssssssscccssssscccssssscccsssscccsscescscssssscscsssscscssesossess 18
28. temmansedgenccesd 29 Changing Meposilon Ol anm ontsier 26 Bf AUR AO OI ss eae A EE E E E I E A AA A EA E E E 26 Adding a new sensor to an O D0X ccccinnineninianndeniuiiieinaeeraesaxiraescaverssesscsctesssesnters 26 COMIN M2 SENSO esaa A 21 Om TAI HS sensor dilancipi deai aiaia aodai 27 DC WS OF Dye CSC UI Oli sates sadenat osatigsa tans doe a ua tedontiselsenauasecans tena uenanecasoratanctoncuasecnns rE 28 A AU APOE ACS ts sarge ae auasaneg c9 E bt gaia pou ener oat ec ueaaue ote soul ensues encod E E E 29 Changing the position Of a SCMSOF cccseccceeeeeceeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeeeeeeea nessa eeeaeeeeseeeeeaeeeeeaaeeeseneeeseeeeneneeeaags 31 PROM ALITA A Sensis atesneg area EEE md anesesenadsnsesvascueeanaannes 31 Working with the Connected SCC cccccssscccsnssccccnssccccssscccssccccsscccessscccesscccessscccesscccessscceeees 32 The About SCC Win Conia didlo srcsrasciennecnrer nna Eia 33 Z001075 0 06 130716_SMO AS Page 3 of 33 STEYR CONTROL CENTER Configuration software users manual STEYRMOTORS Q Abbreviations Controller Area Network Serial communication protocol O Box Input Output box Optional box to connect sensors and to switch loads STEYR CONTROL CENTER SCCWinConfig STEYR CONTROL CENTER this manual describes these software configuration software Introduction With the STEYR CONTROL CENTER Configuration software you can configure your STEYR CONTROL CENTERs The configur
29. the scale Allowed values integer 999 999 e Scale unit unit of the values Scale max value and Scale min value Attention this is not the unit which is shown for the instrument in the SCC software The instrument unit is configured in the common SCC settings The scale unit is needed for a conversion into the different shown units e Enable upper red region enables the possibility to configure an upper red region and a high alarm warning e Upper red region scale value at which the upper red region should start Allowed values interger value must be lower than Scale max value and greater than Scale min value e Enable high alarm if enabled a warning popup appears on the SCC when the sensor value is greater than the Upper red region value e Engine must run if enabled the high alarm warning appears only when the sensor value is greater than the Upper red region value and the engine is running e Enable lower red region enables the possibility to configure a lower red region and a low alarm warning e Lower red region scale value at which the lower red region should end Allowed values interger value must be lower than Scale max value and greater than Scale min value e Enable low alarm if enabled a warning popup appears on the SCC when the sensor value is lower than the Lower red region value e Calibration values see Calibration values below Sensor type description Possbile sensor types are
30. with an application of 1 22 the dialog looks as follows HW STEYR Control Center Configuration Fie Options View Help Time zone UTE 1 Hour a 1 0 Boxes Manual tank gallons Gear ratio 0 Tank volume Propellor pitch 0 ropellor pitch Alarm level 75 Engine List PONA Serial Mumber woe S010 SCC Application ee Alert List Aa Speed Temperature Pressure volume C kmh C Celsius C Bar C Litre knots Fahrenheit F C PSI galons C mph kPa CAN behavior f Master C Slave New is the display of the serial number of the connected device on the right side and the software version number as well as the version number of Engine List engine_list_v2 xml and Alert List alert_list_v2 xml The display is the same as the display of the configuration screen at the SCC Z001075 0 06 130716_SMO AS Page 7 of 33 STEYR CONTROL CENTER Configuration software users manual Connected SCC Application v1 23 or latter If you connect with an application of 1 23 or later the dialog looks as follows HW STEYR Control Center Configuration Fie Options View Help Time zone UTC 8 Hours Serial Number l Manual tank litre Gear ratio 0 T 1 234 Pees s00 SCC Application Propellor pitch E cash ats Alarm level fo Engine List WIE Ih atte Alert List 100 3 Speed Temperature Pressure volume Alert List SE 2 34 35 kmh Celsius fC 0 Bar Litre C Knots C F