Home
CatLinc DA-8 User`s Manual 7.22.03
Contents
1. respect to loss of profit revenue or cost of removal and or replacement Some states do not allow the exclusion or limitation of incidental or con sequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state SP Controls maximum liability shall not exceed the price paid by the user All implied warranties including warranties for merchantability and or fitness are limited in duration to three 3 years from the date of purchase Proof of purchase must be provided with any claim COPYRIGHT CatLinc is a trademark of SP Controls Inc No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without express written permission of SP Controls Inc 2010 SP Controls Inc All rights reserved SP Controls Inc 930 Linden Avenue So San Francisco CA 94080 www spcontrols com
2. SP Controls Inc CatLinc DA 8 s La User s Guide SYSTEM IN Caution This equipment does not allow the distribution of computer signals through Ethernet networking hubs or switches Do not connect this device to a network hub or other communications equipment CatLinc DA 8 1 What is the CatLinc DA 8 system The SP Controls CatLinc DA 8 is a 1x8 Distribution Amplifier for the SP Controls CatLinc proprietary signal type carried over CAT5 CAT5e or CAT6 STP UTP or FTP cable It uses standard RJ 45 connectors for both input and output The CatLinc DA 8 is designed for use with the SP Controls CatLinc fami ly of products It can be used to split the signal carried by the CatLinc VGA CatLinc VGA L CatLinc VID or CatLinc HD from one CatLinc Transmitter to up to eight CatLinc Receivers The CatLinc DA 8 is powered with a 12 VDC power supply When pow ered the CatLinc DA 8 can distribute phantom power to a maximum of 8 CatLinc Receivers NOTE The CatLinc DA 8 can only be used with one CatLinc signal type For example if you connect a CatLinc VGA Transmitter to the CatLinc DA 8 SYSTEM IN the output must be run to CatLinc VGA receivers Mixing different CatLinc Transmitters and Receivers could damage the CatLinc units 2 Connecting the CatLinc DA 8 System a aL SILURCE Ta 12 Power CatLinc Race P aie T e C CatLinec Catlin
3. atus including amplifiers that produce heat 9 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments accessories specified by the manufacturer 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified service personnel Servicing is required when the appara tus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped SP Controls Inc www spcontrols com WARRANTY SP Controls warrants all CatLinc products and accessories against defects in materials and workmanship for a period of three years from the date of purchase Although SP Controls thoroughly tested and reviewed this documentation there is no warran ty express or implied with respect to quality merchantability or fitness for a particular pur pose Therefore the CatLinc and accessories are provided as is and the purchaser assumes the entire risk as to quality and performance There are no obligations or liabilities on the part of the SP Controls Corporation for conse quential damages arising out of or in conjunction with the use or performance of these prod ucts or other indirect damages with
4. g Receiver Transmitter Catling DA oe CatLine DA amp Spilts mast CatLine signal types ta O a tat CatLinc Receiver as many as 4 destinations oa oi Warning In the CatLinc signal distribution system the CAT5 cables carry electrical power Do NOT connect them to any other device We recommend that you attach the enclosed warning stickers provided to the ends of each cable User s Guide 3 Technical specifications System Operating temperature 32 F to 104 F 0 C to 40 C Storage temperature 40 C to 158 F 40 C to 70 C Humidity 80 non condensing relative humidity Warranty 3 Years Cables amp Connectors System In RJ45 1 System Out RJ45 8 Dimensions 4 6 x 3 7 x 1 6in 118 x 96 x 42mm Power supply External Power Adapter 12VDC 2A Order Number CATLINC DA 8 RJ 45 Pinouts The RJ 45 connectors on the CatLinc DA 8 transmit proprietary CatLinc signals of the type which is connected to the unit For more information on sig nal pinout please see the CatLinc User s Manual Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other appar
Download Pdf Manuals
Related Search
Related Contents
11101, 11108 & 11151 INSTALLATION INSTRUCTIONS Alcatel One Touch 992D White F I E GB D NL Manual de usuario User Manual of iVMS-4000(V2.03.07) mode d`emploi - Chemins du Rail Copyright © All rights reserved.
Failed to retrieve file