Home
Installation & User Manual V2.02
Contents
1. 1 and 2 activate deactivate the Alarm 5 Panel W hen the Alarm Panel is activated all other users are locked out See notes on Page 16 for explanation of feature 12 24 VAC Common OV from the Intruder Alarm Panel and the OV from the Keypad to avoid any ground loop issues 12 24 VAC Note All OV shown in the diagram are connected Wiring for StikeLock only using 12 24VAC supply to OV at the back of the keypad terminal block Notes Invalid PIN Lockout Entering an invalid PIN 3 times will lockout the keypad for 15 seconds All lights will flash during this time Turning this feature off reduces the security of the keypad Number of PIN Digits The number of digits each User PIN will contain 4 or 5 or 6 The number of digits can not be reduced after a User PIN has been added lf the number of PIN digits is increased then add leading Zeros to existing PIN s E G if increasing PIN digits from 4 to 5 then existing PIN code 1234 changes to 01234 Relay Active Time This is the amount of time the relay will remain active Entering 0 for the relay active time will generate a 200 millisecond pulse Ajar Alarm This alarm will activate if the door is open longer than the Door Ajar Time Door Forced Alarm This alarm will activate if the door contact is forced open Anti Tail Gate If this option is set the door relay time is shortened to 2 seconds Guest Button If this option is set then the tick key can be
2. 4444 To Confirm Standard Card amp PIN Example To Add a Toggle Card amp PIN Card number 00001234 PIN 4444 X key then To Confirm Toggle Card amp PIN Example To Add a Mgr User Card amp PIN Card number 00001234 PIN 4444 To Confirm Mgr User Card amp PIN Description Removing a Batch of Cards Example To remove a Single Card To Confirm Card removal Example To Remove a Batch of Cards a Present First i Present Last Card in batch Card in Batch To Confirm Card removal Removing a Card and PIN Description 08 Removing a Card and any associated PIN 09 Removing a Card and any associated PIN using Keypad Present card to remove To Confirm Card PIN removal Example To Remove a Card Example To Remove a Card using Keypad Card number 00001234 To Confirm Card PIN removal E Table 1 W iring Diagrams Change the Number of PIN Digits Default Button Contact Buzzer i Door 1 Exit Door 1 Follow 11 P Genge e tnaneer Code o IS A L die oe Door 1 Exit Fire Alarm Alarm p 13 Change the Door Ajar Time 30 seconds 2 255 2 Buton Dende Buzzer age Change the Guest Buzzer Time 3 seconds 1 10 Door 1 interlock EE asad 3 Contact VP O P age Door 1 Exit Alarm Panel Alarm Panel Note The Number of PIN digits can not be reduced once a User Pin has 4 DR O Margaret Aegean pagers been added Example To Change the Engineer Code Turning Features ON or OFF Note 0 Off
3. AddBatch of Cards using Keypad 08 Remove Card and associated PN 09 Remove Card and associated PIN wih Keypad FAGEPIN 45 6 on 5566 Change the Relay Active Time 5 seconds 0 255 30 seconds 2255 3 seconds 110 oF on on of 24 Set Toggle Relay on off On 25 Set Door Forced Alarm on off On Off _ Change the Input and Output Options 0 _Restore Factory Default Settings
4. 1 On Example To Set the Backlight to always stay ON Description 30 Change the Input and Output Options Example Installation Diagrams _ Flush Mounting Keypad is mounted to pattress box using security screws provided Both Security Caps are Fix Surface M ount Collar to Taen E IPPEG ONTO aL wall ensure arrow is pointing upwards Surface Mounting Fix Surface M ount Collar to wall as above After wiring is complete Keypad may then be screwed to Surface M ount Collar using security screws provided Both Security Caps are then f clipped onto keypad X A P wp 1 i y 1 i 1 i 1 To attach Security Caps hook tabs into holes and push on To release Security Caps pusha screwdriver into slots on the side and pull forward To attach Security Caps hook tabs z into holes and push on Gy Wiring Diagrams W iring Diagrams for Door 1 sa 12V Linear Power supply IP1 IP2 0 TAMP Door MagLock Volt Free Tamper Contacts 1 and2 12 24 VAC 12 24 VAC Wiring for StikeLock only using 12 24VAC supply ae Door 1 Exit Button A 12V L E J iS Note All OV shown in the diagram are connected to OV at the back of the keypad terminal block Wiring Diagrams E W iring Diagrams for Door 1 and Fire Alarm Override 12V Linear Door 1 Exit Button K Power supply
5. Other products from GSD global security devices is the next generation in access control solutions It provides a Wireless Network throughout the premises giving the convenience and security of a fully networked system for a fraction of the cost ee eae a i Operation Instructions PD LESESECTCI ISSCC ETT ESE Eee E eer re 4 Installation Diagrams ED Wiring Diagrams ED For more information on the Wireless Network System visit our website Quick Reference www globalsecurity ie Administration Notes E global security devices Pin and Proximity Technical Specs z R 12 24V AC or DC Adding and Removing PIN s 100mA Current consumption with load max 130mA Code Deseription ee Relay Contact Rating 5 Amps 240V ac 01 a Standard User Toggle User Manager User Remove any User PIN P67 sane To Add User PIN 656 Factory Default PIN codes The following PIN codes are the Factory Default Settings The Default Engineer code is 6666 User PIN 1111 Note The User PIN 1111 is deactivated when the first User PIN is added to Engineer PIN 1234 the keypad Restoring Factory Settings 55 Restore Factory Default Settings Example Note If Engineer code is lost Remove the Security Caps see page 11 and hold down the X key during power up and enter the default Engineer code 6666 immediately This will restore the factory settings Adding a Batc
6. h of Cards or Fobs Description 04 Add Batch of Standard Cards Toggle Cards Manager Cards Example To Add a Single Standard Card X_key then Present Present Engineer Code 04 T T new card again 162 To Confirm Standard Card Example To Add a Batch of Standard Cards Present First Present Last Code 04 Card in batch Card in Batch QB To Confirm Standard Cards Example To Add a Batch of Toggle Cards Present First Present Last Code 04 Card in batch Card in batch Gt To Confirm Toggle Cards Example To Add a Batch of Manager User Cards Present First Present Last Card in batch Card in batch To Confirm Manager User Cards Description 06 Add Batch of Cards using Keypad Example To Add a Single Standard Card Card number 00001234 QD To Confirm Card TeS To Confirm Card To Confirm Standard Card Example To Add a Batch of Standard Cards Batch 0000200 to 0001000 To Confirm Card To Confirm Card To Confirm Standard Cards Example To Add a Batch of Toggle Cards Batch 0003200 to 0004000 Code 06 To Confirm Card JEDE To Confirm Card To Confirm Toggle Card Example To Add a Batch of Manager User Cards Batch 001200 to 001250 To Confirm Card To Confirm Card To Confirm Manager User Card Description Add a Card and a User PIN Example To Add a Card amp PIN Card number 00001234 PIN
7. i Fire Alarm Panel f j OV IP2 0 OP1 C N 4 com TAMP 05 N TAMP l 0V W hen the fire alarm is activated 0V removed from IP2 the door will be opened V Door 1 D D p A D Contact T D Door MagLock 12V Sounder or Follow Volt Free Tamper Contacts K 12 24 VAC Sounder n com NC Common OV from the Fire Alarm Panel and the OV from the Keypad to avoid any ground loop issues Note All OV shown in the diagram are connected to OV at the back of the keypad terminal block 12 24 VAC Wiring for StikeLock only using 12 24VAC supply Z Wiring Diagrams Wiring Diagrams for Door 1 and Interlock connections 12V Linear Power supply Door 1 Contact A j o OV 12V IP1 OV IP2 NO OP1 ore MU NC TAMP Interlock OP to Interlock IP on 2nd Door Interlock IP from Interlock OP on 2nd Door Door MagLock Volt Free Tamper Contacts 1 and 2 12 24 VAC Lo Note All OV shown in the diagram are connected Wiring for StikeLock only using 12 24VAC supply to OV at the back of the keypad terminal block Wiring Diagrams ED W iring Diagrams for Door 1 and Alarm Panel connections f 12V Linear Door 1 Exit Button _ Power supply Alarm Panel O Arm Output N O PAY IP1 O Arm Alarm Input ov IP2 NO OP1 ore MPU NC TAMP t 4 4 Door MagLock Volt Free Taniper Coffacts Only the Manager User can
8. used to sound the buzzer Silent Operation If this option is set then all audible tones are silenced Duress codes If this option is set the door will open but the alarm will be activated if the duress PIN code is entered duress PIN code is the code above the user PIN code e g user code 8 888 then duress code 8 889 Toggle Relay If this option is set then the door will remain open or closed on each PIN entry for a Toggle User Manager User If the Alarm Panel option is setup using the IO options then only the Manager User will be granted access if the alarm Is set The Manager User is the only user that can activate or deactivate the Alarm Panel The RED light Flashes to indicate the Alarm Panel is set The Manager User must press the tick key and enter a PIN code to activate the Alarm Panel or present a M anager User card twice To deactivate the Alarm Panel the Manager user enters a PIN code lf the Alarm IS deactivated then the M anager User operates as a standard user Card Or Pin mode allows both valid Cards or PIN codes to gain access Card And PIN mode Only Users with a valid Card and an Associated PIN code gain access Card And Any PIN mode Users with a valid Card and any valid PIN code gain access This mode allows a group PIN to be used with valid Cards Quick reference Quick Reference M enu Codes Code Description Default Settings Add a User PIN to Door 1 1111 Remove a User PIN oe E 06