Home

iChip Config Utility User Manual

image

Contents

1. Figure 14 50 Addressee Window Type the email addresses in the Address column and then click OK The mailing list is saved 8 In the Address Description field type the name of the person to whom you are sending an email 9 Inthe Return Email Address REA field type the email address to which the email recipient should reply 10 In the Sender Description FRM field type the name of the sender of the email Example email scenario If you want the iChip to send an email from the device to a person monitoring data collected by the device say Person1 you might type Person1 s email in the Email Address field Person1Qemail com and then type Person1 in the Address Description field If in this scenario you want replies to the email sent to you you would type your email address in the Return Email Address field youGemail com In the Sender Description field you might type the name of the device collecting the data 11 If you want to send copies of the emails sent from the iChip in the Alternate Addressee fields CC1 CC4 type the email addresses to CC 12 In the Message Body BDY field type a message to appear in the body of the email 13 From the Media Type MT dropdown list select the media type to use when sending an email audio video application or text Page 18 of 70 Connect One iChip Config Utility User Manual 14 In the Media Subtype String MST field type the name of the
2. 4 3 4 4 3 5 Connect One iChip Config Utility User Manual Configuring the Host Interface When iChip is in SerialNET it cannot determine the local serial port automatically since the Network may be the originating side Therefore you need to specify the Host interface to be used How m After you complete the flush conditions configuration Section 4 3 3 and click Next the Host Interface dialog appears Figure 59 gt SerailNET Getting started Wizard Host Interface Available Host Interfaces A UART 0 vi Back Next Cancel Figure 49 Host Interface From the Dropdown list select the Host interface that will be used as the local serial port the SerialNET mode Configuring Serial Settings This procedure describes how to configure the serial settings parameters for working in Serial NET mode How After you complete the Host Interface configuration Section 4 3 3 and click Next the Serial Settings area appears Figure 50 Page 62 of 70 4 3 6 Connect One iChip Config Utility User Manual SerailNET Getting started Wizard Senal Settings What is the baud rate used by your device 3600 How many data bits does your device use fr 8 bits C 7 bits What type of Panty does your device use None C Even C Odd Does your device use hardware flow control amp Ho C Yes Figure 50 SerialNET Getting Started Wizard Serial Settings In th
3. Target Audience This document is intended for users of Connect One products who need to know how to configure the products firmware and parameters with the iChipConfig Windows based GUI Related Documents E AT i Programmer s Manual Page 5 of 70 1 1 1 2 1 3 1 3 1 Connect One iChip Config Utility User Manual Introduction iChip Config Utility Overview System Requirements iChipConfig Utility Menus iChip Config Utility Functionality iChip Config Utility Overview The iChip Config Utility combined with any of Connect One s products enables quick and full configuration of the iChip serial based and web based updating of firmware and packaging of a website and parameters file Connect One s iChip Internet Controller is an Internet peripheral chip that offloads Internet connectivity tasks from a host processor The host processor communicates with the iChip via Connect One s high level AT i command set The iChip Config utility enables you to configure and use the iChip without any need to know or use the AT i commands either for evaluation purposes or for updating your existing configuration The AT i commands are translated through the user friendly GUI All you need to do is define the parameters as described in each section of this manual System Requirements To work with the iChip Config Utility you need the following A PC with a free RS232 COM port A device board module using the iChip yo
4. following Clock Out To set Pin 44 to provide a clock signal at the same frequency as iChip s clock input signal X1 Pin 42 Heartbeat iChip outputs a square wave frequency 80mSec with a 50 duty cycle From the Watchdog Activation Mode WDM dropdown list select either Disabled default or Enabled activates FW monitoring if a problem is encountered a hard reset takes place In the Readiness Report HW RRHW field specify which of iChip s general purpose I O pins GPIO will be asserted Low to indicate iChip readiness to the host Specify 0 to disable A value of 1 6 corresponds to pins PIOC 0 5 In the Content Type CTT field specify the content of the Content type field that is sent in the POST request This field specifies the type of the data file being sent When left empty a default value of application x www form urlencoded will be used and the server will expect the data to be the data sent ina Submit of a form From the LAN Type LTYP dropdown list select the prefered LAN when the iChip is connected both to an Ethernet and WiFi LAN When set to its default 0 iChip shall automatically detect the LAN platform and if both exist iChip will prefer the WiFi In the Web site Logo LOGO field specify the filename of a GIF file the contains an alternate Logo image to be displayed in iChip s Configuration site The default value specifies Connect One s Logo image Sele
5. type the iChip network host name or a unique identifying name for a LAN or dialup environment In the Baud Rate Divider BDRD field specify a value of 1 255 This will be used to define the Host interface baud rate as 3M BDRD when one of the COM ports is used as the Host interface From the Framing Mode FMOD dropdown list select the Framing Disabled 0 or Enabled 1 From the PPP ACFC negotiation PPP dropdown list select the ACFC negotiation mode appropriate for the PPP protocol being used Select the Auto Router Start ARS checkbox to specify that iChip should automatically Power up into iRouter mode This flag should not be specified when the BRM parameter specifies Bridge mode Select the Calculate Checksum CKSM checkbox to instruct iChip to calculate the checksum of Send and Receive Write and Read commands If a checksum error is encountered the data is retransmitted Page 23 of 70 Connect One iChip Config Utility User Manual 39 40 41 42 43 44 45 46 47 48 In the Timeout to Resend PING Request PGT field type a value in seconds to set the time interval after which iChip reissues an unanswered PING request In the Timeout to Resend Unacked TCP Packet TTR field type a value in seconds to set the time interval after which iChip retransmits an unacknowledged TCP packet over PPP connection From the Select Pin 44 Function PN44 dropdown list select one of the
6. 0 CDPD Password CPWD Max PPP Packet Size MPS 0 Auto v Host Interface HIF 1 UART 0 v A2D detect period interval ADCT Bridge Mode BRM 2 Device to AP Web Server Port WEBP 0 Log Interface and Spec LIF 0 Cellular PIN CPIN Baud rate BDRM fa Auto Baud Rate vi Fix baud rate BDRF E 115200 v Flow control FLW No flow control Y Disable reflection Dial Mode DMD Tone v Activate Web Server AWS Disabled v Triggered UP TUP Disabled v Modem Interface MIF 2 UART 1 v A2D detect threshold level ADCL 0 A2D detect GPIO Pin 0 A2D detect threshold delta ADCD 0 SPI Control Signal SPIP 0 MAC Filter MACF TCP Window Buffer TWB 0 Log Group LGRP USB VBUS pin BUS Operational Network Time Of Day Active NTOD Network Time Server NTS1 Network Time Server 2 NTS2 Greenwich Mean Time Offset GMTO 0 Daylight Saving Time Definition DSTD I IP Prot Don t Fragment Bit DF AT i Socket Server LATI 0 Host name HSTH Baud Rate Divider BDRD 0 Framing Mode FMOD 0 Framing Disabled v PPP ACFC Negotiation PPP 0 Agree to ACFC v LATI Restriction LAR 0 10 Configuration IOC M Auto Router Start ARS WAN Selector WANS 0 Log Trigger Event LTRG 0 USB Interface Number USBI are Port COM12 LAN Calculate Check Sum CKSM Timeout to resend PING request PGT 0 Timeout to resend un
7. 1 and 65535 However it is recommended that you choose a number higher then 1024 2 Click Next The Flush Conditions area appears see section 4 3 3 Setting Flush Conditions and your device is configured to either initiate a TCP session or wait for one as applicable I You can also configure the iChip with both parameters using the Full Configuration tool see section 3 3 10 or using AT i commands see the AT i Programmer s Manual 4 3 3 Setting Flush Conditions This procedure describes how to set the flush conditions for working in SerialNET mode By default every packet that comes from the Internet is immediately stripped of TCP or UDP headers and the raw ASCII data is forwarded to the device However every character that iChip receives from the device side is buffered until a flush condition is achieved Then the buffered content is sent as a TCP or UDP packet to the remote side The flush conditions iChip supports include the following parameters Content Applicable if your device terminates each transmission with a fixed character IChip scans the character stream until the specified character is detected and then sends the buffered content including the termination character as a packet Page 60 of 70 Connect One iChip Config Utility User Manual Quantity If your device has a fixed number of bytes per transmission iChip counts the specified amount of bytes in the stream When the buffer r
8. 4 2 4 1 7 ee mlt sl After you click Next in the first Communication Platform Wizard window the ISP Account Parameters area for GPRS appears Figure 40 lt Communication Platform Wizard i x Enter ISP Account parameters Phone number fart ooo User name Optional Password Optional Modem init string HCGDCONT 1 I1P Progp Figure 40 Communication Platform Wizard GPRS Parameters In the Phone Number field type the number you use to connect to your ISP In the Username field type the username you use to access your ISP account In the Password field type the password you use to access your ISP account In the Modem init string field type the initialization string for your modem Click Next The Finish View Settings area appears Figure 42 Continue with Viewing and Completing Communication Platform Configuration Configuring LAN Settings This procedure describes how to configure LAN communication platform parameters using the Communication Platform Wizard What you need Completion of Starting the Communication Platform Wizard with the LAN parameter selected Page 55 of 70 CS How 1 4 2 5 C7 How 1 Connect One After you click Next in the first Communication Platform Wizard window the LAN Parameters area appears Figure 41 Communication Platform Wizard Does your network automatically assign IP addresses for pou fr Yes i Ho IP Addre
9. AT iAWS 3 and press Enter 10 Click Go The iChip webpage is displayed Figure 34 and you can perform your firmware update Page 50 of 70 Connect One iChip Config Utility User Manual Enter iChip IP Address 72 70107 40 Go Close HIF Device to thee Connect ne gt gt gt Files Upload ichip Web Server Status Message Ok Website to upload Browse rof file to upload Browse Firmware imz file to upload Warning After starting the upload do not stop the process until seeing the upload complete screen Browse E Figure 35 Website Uploader Window Displaying the Webpage for the Update 3 7 Working with the Dumb Terminal This procedure describes how to work with the dumb terminal of the iChipConfig utility The dumb terminal enables you to input AT or AT l commands and to review the iChip or modem response You can also configure your port and baud rate in the Dumb Terminal What you need m Device or module using Connect One iChip or Connect One II EVB board connected to your workstation with power on CS How 1 In the iChip Configuration Tools window click the Dumb Terminal R The Dumb Terminal window appears Figure 36 Page 51 of 70 Connect One iChip Config Utility User Manual gt Dumb terminal File Edit Text options attiplnk http wuw connectone com I OK 1 1821 peace ee Poledden TCP IP Internet Controller adapters with email
10. Config Utility User Manual Wizards m Wizards Overview Communication Platform Wizard m SerialNET Configuration Wizard Wizards Overview The iChipConfig utility includes two wizard that take you through the configuration process Communication Platform Wizard Takes you through configuration of parameters for the communication platform SerialNET Configuration Wizard Takes you through configuration of SerialNET mode details Communication Platform Wizard Starting the Communication Platform Wizard This procedure describes how to access the Communication Platform Wizard and begin to define iChip parameters How 1 From the iChipConfig main menu bar select Wizards gt Communication Platform The Communication Platform Wizard window appears Figure 38 Communication Platform Wizard Please choose your communication platform Dialup ka Hext Cancel Figure 38 Communication Platform Wizard Window 2 From the Communication Platform dropdown list select the communication platform you are using Dialup GSM GPRS or LAN and then click Next Page 53 of 70 4 2 2 Fj Connect One iChip Config Utility User Manual The window for the selected communication platform opens enabling you to configure applicable parameters Related Topics Configuring Dialup or GSM Parameters This procedure describes how to configure dialup communication platform parameters using the Comm
11. Params Tab of Full Configuration Tool 2 Inthe Remote Update Password RPG field type the desired password or ensure the field is clear if you do not want a password defined 3 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply Page 29 of 70 Connect One iChip Config Utility User Manual To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears Configuring the HTTP Tab This procedure describes how to configure parameters for Web updates What you need Access to the Configuration Tools window as described in 3 3 1 How 1 In the Configuration Tools window click HTTP tab The HTTP tab configuration fields are displayed Figure 22 gt iChip Configuration tools File Search Parameter Content Transfer Encoding CTE iChip type C02144 D iChip plus LAN platform Firmware ver D809b155 42012 Serial num 14001040 Boot block 0801 9 6 2009 Baud Rate 115200 Figure 22 HTTP Tab of Full Configuration Tool 2 Inthe URL to Retrieve URL field type the URL of the HTTP page or item such as a picture for iChip to retrieve 3 In the Web Password WPWD field type a password as follows fa password is not set field is blank Web parameters cannot be set via a Web browser lf
12. individual parameter size per parameter Only parameters that appear in the web site being packed will be affected The file in a TXT file and the format is Parameter SizeCR LF Any line that starts with will be regarded as remark and ignored 3 6 Working with the iChip Uploader via HTTP Tool This procedure describes how to perform an update on the iChip from a webpage loaded on the iChip or load a website on the iChip A What you need m Device or module using Connect One iChip or Connect One II EVB board connected to your workstation with power on Website loaded on iChip with an update option available G How 8 In the iChip Configuration Tools window click the iChip Uploader via HTTP as icon The Web Uploader window appears Figure 32 Page 49 of 70 Connect One iChip Config Utility User Manual Web Uploader Seles File Enter iChip IP Address PO Go Close Uploads a host site to iChip via HTTP Port COM1 Baud Rate 115200 Figure 33 Web Uploader Window 9 In the iChip IP Address field type the IP address of your iChip gt To get the iChip s IP address a Close the Web Uploader window b Inthe iChip Configuration Tools window click the Dumb Terminal 284 icon The Dumb Terminal window opens c In the Dumb Terminal window type AT iipa and press Enter The iChip IP address is displayed gt Enable iChip s web server a Inthe Dumb Terminal window type
13. see CERT parameter below when performing client side authentication 5 Inthe iChip Certificate CERT field you can load iChip s SSL3 TLS1 certificate Some SSL3 TLS1 servers require the client side to authenticate its identity by requesting the client to provide a certificate during the SSL socket negotiation phase This is called client side authentication If the CERT parameter contains a certificate iChip provides it to the server upon request iChip also needs a private key See PKEY parameter above in order to encrypt its certificate before sending it to the server In addition the certificate must be signed by a certificate authority accepted by the server for the client side authentication to succeed 6 Fill in fields as required and then do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 16 Using the Full Configuration Menu e File Menu Use the File Menu to save all iChip parameters to an RPF file When selecting this option the following dialog will be displayed RPF parameters Include these parameters in RPF file Start from factory defaults Select Start from factory defaults to save all parameters with value different
14. value is set to 0 every packet iChip generates is sent to the host If the value is set to 2 two packets are ignored and then the next packet is sent and so on 17 In the SerialINET Wakeup Timeout SWT field type the value in seconds of the time interval to elapse for iChip to cease attempting to wake up a remote SerialNET server 18 In the HSS field enter a string containing three control characters that determine switching among the three possible remote servers HSRn 19 In the SerialNET Indicator Signal SLED field specify the GPIO to use to drive a LED indicator when iChip is in SerialNET Specify 0 to disable A value of 1 6 corresponds to pins PIOC 0 5 The specified GPIO shall be driven LOW when iChip is in SerialINET mode 20 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply Page 32 of 70 Connect One iChip Config Utility User Manual To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 11 Configuring the IP Registration Tab This procedure describes how to configure IP Registration parameters which enable iChip to broadcast online status and information A What you need Access to the Configuration Tools window as described in 3 3 1 G How 1 In the Configuration T
15. 03 Cancel 6 The Monitor Mode dialog box is displayed Click the FW Update button gt Monitror Mode Connect Sne gt General Settings Baud rate 115200 Scan Operations Fw Update Memory Dump Dump Memory to file Exit Monitor mode 7 In the dialog box that appears browse to the location of the Boot Block IMF file you obtained from Connect One select the file and click Open Page 42 of 70 Connect One iChip Config Utility User Manual SE x Look ir I mf EE aa atsildr dmp ar BBESABO204 map 1561 replaceBB 5 LD BBO101 1MF BBESEBO203 IMF 1661 replaceBB 5 L D BE0102 1MF lan BBESEBO203 map E 880103 IMF a BBESEBO204 IMF JBootBlkengaged l bbo104 hex la BBESEBO204 map E BED104 IMF bbfm0105 axe 38 EBE5AB0203 IMF bbfm0105 imf ak i BBESABO203 map BEFMO106 hex 204 IMF lan BEFMO0106 IMF EE BBESARO204 IMF Files of type A files v Cancel Open as read only My Network P E 8 Click Yes when prompted x re you sure you want to send file 11172 20 0 111DeviBookbliImfBBES4B0204 IMF 9 The following window appears while certain sectors of the flash are being erased and the boot block is being installed a Time Elapsed 00 00 01 Total Size 041 00 Cancel 10 OK the dialog box that appears when the boot block has been installed successfully ichipconfig se Image fil
16. 40 tt eula 1041 txt eula 1042 tat Load File Fill Gare MIB File Flatform C0272128 Default Page SNMP Enabled Web Site Pack Close Fack a web site to iChip format Port COM12 Baud Rate 115200 Figure 30 Website Packer Window 1 From the Platform dropdown list select the iChip platform you are working with In the Select Directory area locate the website root directory Select a file as the default Home Page of the site By default the Packing tool will select index htm index html as the default home page if such a file exists in the root directory Page 48 of 70 Connect One 4 Click Pack iChip Config Utility User Manual The Website Packer window refreshes displaying the website parameters in the Max Parameter Value area Figure 31 Param Mame st Parameter Parameter Parameters Parameter Parameters Parameter Parameter Parameters st Param max size 10 ah r Figure 31 Website Parameters 5 Do one of the following Inthe Param Max Size column type the value for each parameter Select the parameters to be filled and in the Fill Selected Parameters with Value field type a value and then click Fill All selected parameters are updated with the defined value 6 Click Save Define or select a filename The default file extension is set to IMG 7 Click Close ra Also you can choose the Load file button to submit a file that holds D
17. HTTP Web WYAF Serve t frames frameset rows 95 horder gt frame name top src htmlTopMenu hp asp marginvidth 8 marginheight A scrol frameset cols 236 hborder gt frameset rows 344 border 8 gt lt frame name left top src htmlBanner asp marginwidth 6 marginheight lt frame name left huttom src html blank htm marginwidth 80 marginheighi lt Frameset gt frameset rows 20 horder gt frame name main top src html search htm margqinwidi frame name main src htmlindex in htm marginwidth 0 marc lt frameset gt lt Frameset gt lt fFrameset gt lt t frames gt I ONLINE at irpB CO21 AG D lt 33MHZ IZOE at irpi ID7A6BA3 19 12 2664 1 0K I Setup port Change iChip Baud rate Close Port COM Baud Rate 115200 Figure 36 Dumb Terminal Window 2 To select a COM port and baud rate click Setup Port The Serial Settings window appears Figure 37 enabling you to select a port and baud rate Serial Settings Serial Port Baud Rate COM 115200 Select port and baud rate or select Scan to scan all baud rates and click OK Cancel OK Figure 37 Serial Settings Window 3 To change the baud rate you are working with click Change iChip Baud Rate The Serial Settings window appears Figure 37 enabling you to select a port and baud rate Page 52 of 70 4 1 4 2 4 2 1 Connect One iChip
18. LAS SSID4 WSI4 3 Enterprise Password EPSW WLAN Security type Security type 0 WSTO D No Security v Security type 1 WST1 0 No Security v Security type 2 WST2 0 No Security v Security type 3 WST3 0 No Security v Security type 4 WST4 WLAN WPA Pass Phrase WPA PSK Pass phrase LPP WPA PSK Pass Phrase 1 WPP1 WPA PSK Pass Phrase 2 WPP2 WPA PSK Pass Phrase 3 WPP3 WPA PSK Pass Phrase 4 WPP4 fo No Security Security type 5 WST5 Le WPA_PSK Pass Phrase 5 WPP5 fo No Security Security type 6 WST6 Lo WPA PSK Pass Phrase 6 WPP6 Lo fo No Security Security type 7 WST7 fo No Security Security type 8 WST8 0 No Security Security type 9 WST9 0 No Security v WPA PSK Pass Phrase 7 WPP7 Le WPA PSK Pass Phrase 8 WPP8 Le WPA PSK Pass Phrase 9 WPP9 ir hin hma PAY AA N ihin mhis fl AK mlatfarmsl Ready Port COM12 SSID5 WSI5 SSID6 WSI6 SSID WSI7 SSID8 W518 SSIDS WSIS WEP Multi SSID Keys WEP Key 1 WKY1 WEP Key 2 WKY2 WEP Key 3 WKY3 WEP Key 4 WKY4 WEP Key 5 WKY5 WEP Parameters WEP Mode WLWM WEP disabled v Key Index WLKI 1 Key 1 WLK1 Key 2 WLK2 Key 3 WLK3 Key 4 WLK4 Yv WEP Key 6 WKYG WEP Key 7 WKY7 WEP Key 8 WKY8 WEP Key 9 WKY9 Firmwares var INSNAKIAR A A 27179 Baud Rate 115200 F
19. acked TCP packet TTR 3000 Select PIN 44 function PN44 Clock out v Readiness Report HW RRHW 0 Content Type CTT LAN Type LTYP 0 Automatic v Web Site Logo file LOGO liChipimages ConmectOne gif Power Save Mode Enable PSE 0 Service Disable Mask SDM Disable Ping Replies I Disable Remote Debug Disable Unauth Web Server Disable SHET escape by Disable Break Reset Disable Internal Config Site I Disable DHCP until DNS is resolved Big FIFO Size BFS Log Stop Event LSTP 0 rm CHC Cananhin Baud Rate 115200 Ready Figure 16 Operational Parameters Tab of Full Configuration Tool 2 For use with modem operation only from the Extended Return Code XRC dropdown list select a value to determine the message response mode in particular to activate or deactivate blind dial mode If you select 0 Blind Dial from the dropdown list make sure the Blind Dial checkbox is also selected 8 3 Inthe Modem Initialization String MIS field type the string that initializes the modem refer to your modem s user manual for more information XRC is identical to ATXn and is applicable only for modem operation or ll EVB in iModem mode For more detailed information on the ATXn modes refer to an AT Command Set reference source 4 From the Modem Type Designator MTYP dropdown list select the modem type to use with the iChip 9 5 Select the Suppress ATZ checkbox to prohibi
20. address for your network In the Gateway field type your gateway address Make sure the Use DHCP checkbox is clear oa The MAC Address and Assigned IP Address fields are filled D automatically and cannot be modified 3 Select the Use IP Finder checkbox to use the Connect One utility that finds iChip IP addresses on the network and activates the iChip Web server enabling remote configuration of iChip through a browser 4 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 6 Configuring the Remote FW Tab This procedure describes how to configure parameters for remote firmware FW updates Remote FW updates can be performed via FTP or HTTP Update files are saved on a server whose location is defined in the Remote FW tab What you need Access to the Configuration Tools window as described in Section 3 3 1 C7 How 1 In the Configuration Tools window click the Remote FW tab The Remote FW tab configuration fields are displayed Figure 18 Page 26 of 70 Connect One iChip Config Utility User Manual gt iChip Configuration tools File Search Parameter Wireless LAN Firmware update server USRY Firmware update serv
21. assword field type the password for the ISP account d Select the Blind Dial checkbox to instruct modem to dial out without waiting for a dialtone for example in a cellular modem environment To configure iChip LAN parameters a Determine whether you are working with a DHCP server or in fixed IP address mode b To work in DHCP mode Select the Use DHCP checkbox Sets the values of the Default IP Address Subnet and Gateway fields to 0 0 0 0 and disables these fields for input To work in fixed IP address mode Page 14 of 70 Connect One iChip Config Utility User Manual Make sure the Use DHCP checkbox is clear In the Default IP Address field type the IP address for the iChip In the Subnet field type the subnet address for your network In the Gateway field type your gateway address oo 0 ODW Select the Use IP Finder checkbox to use the Connect One utility that finds iChip IP addresses on the network and activates the iChip Web server enabling remote configuration of iChip through a browser A The MAC Address and Assigned IP Address fields are filled D automatically and cannot be modified 3 To configure iChip General parameters For sending email a Inthe SMTP Server field type the name string or IP address of the SMTP server you use to send emails b Inthe Destination Email Address field type the email address to which you want to send an email c Inthe Return Email Address field type
22. ation Tools window click the Quick Configuration Z icon If you are using iChip or Il EVB the lt product gt Quick Configuration window appears Figure 10 Page 13 of 70 Connect One iChip Config Utility User Manual gt iChip plus Quick Configure Connect Ine iChip parameters General parameters ISP Telephone number SMTP Server ee ooo User name Destination email address ron hallel gmail com T T Return email address ron hallel amp gmail com Blind dial POP3 Server Default IP address Assigned IP address omme fo fo fo jo for j fellen iChip LAN parameters Sub Het MAC address Mailbox password jo fo fo fo Gateway pp fo fo Use DHCP DNS2 Use IP Finder b fo fo fo pp fo fo iChip type CO7114G D 33MHZ iChip plus Serial platfo Firmware ver 1D708D21 29 5 2006 Serial num 0000061F Boot block 0708 3 1 2006 Close gt Ready Port COM1 Baud Rate 115200 Figure 10 iChip Quick Configuration Window 2 Do the following To configure iChip modem parameters a Inthe ISP Telephone Number field tyoe your ISP telephone number outside line For example if you must dial 9 to get an outside line type 9 xxx xxxx where Xxx xxxx is your ISP number If required include the area code as well I Make sure you include any number required for access to an In the Username field type the username of the ISP account In the P
23. cify the pin number that iChip will use to control the SPI flow direction Specify 0 to disable A value of 1 6 corresponds to pins PIOC O 5 In the MAC Filter MACF field specify a MAC address to enforce filtering out of any packets that are not from this MAC address in LAN to WiFi Bridge modes BRM 1 or 3 Leave this field empty to disable MAC filtering Select the Network Time of Day NTOD checkbox to enable iChip to set the time according to a network time of day server In the Network Time Server fields NTS1 and NTS2 type the name or IP address of the primary and secondary optional network time server In the Greenwich Mean Time Offset GMTO field type the difference in time in hours between the iChip location and GMT For example if the iChip location is one hour ahead of GMT type 1 If the iChip location is one hour behind GMT type 1 In the Daylight Saving Time Definition DSTD field enter a Daylight Savings Time transition rule This rule must contain start and end dates for DST Select the IP Prot Don t Fragment Bit DF checkbox to disable bit fragmenting in outgoing IP packets To enable sending remote AT i commands to the iChip in the AT i Socket Server LATI field type the name number of the listening COM port When the iChip is connected to the Internet it opens a TCP IP listen socket on the local IP address and specified port that can receive remote AT i commands In the Host Name HSTN field
24. col CTS Clear to Send Indicates modem is ready to send information Dynamic Host Configuration Protocol DNS DTR Data Terminal Ready Computer issues DTR to the attached modem to indicate it is ready to receive data File Transfer Protocol GSM Global System for Mobile communications Graphical User Interface Hypertext Markup Language HTTP Hypertext Transfer Protocol IMF Image File extension Internet Protocol ISP Internet Service Provider Local Area Network MTU Maximum Transfer Unit Network Address Translator Password Authentication Protocol PING Packet Internet Groper POP3 Post Office Protocol 3 Phase Shift Keying RAS Remote Access Service RS232 Interface for single ended serial communications as in between a computer input output port and a peripheral device RTS Request to Send This command puts the modem in originate mode so it can start transmitting SMTP Simple Mail Transfer Protocol Page 69 of 70 Connect One iChip Config Utility User Manual Secure Socket Layer Protocol that manages the security of message transmissions in a network Transmission Control Protocol User Datagram Protocol Wired Equivalent Privacy A security protocol that uses a series of keys on both sides of a wireless transmission to encrypt data for secure transmission WiFi Protected Access Uniform Resource Locator Page 70 of 70
25. corresponding WSI field 6 Inthe WLAN WPA Pass Phrase group a Inthe WPA PSK Pass Phrase WLPP field enter an ASCII string containig 8 63 characters to be used in generating a WPA PSK encryption key b In the WPA PSK Pass Phrase WPPi field enter an ASCII string containing 8 63 characters to be used in generating a WPA PSK encryption key for the AP whose SSID is specified in the corresponding WSl field 7 Inthe WEP Multi SSID Keys group a Inthe WEP Key i WKY field specify the WEP key to use to connect to a WEP secured AP whose SSID is specified in the corresponding WSl field 8 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply Page 38 of 70 Connect One iChip Config Utility User Manual To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 15 Configuring the SSL Tab This procedure describes how to configure user fields related to Secure Socket Layer SSL encryption What you need m Access to the Configuration Tools window as described in 3 3 1 m Knowledge proficiency in SSL encryption and certification How 1 In the Configuration Tools window click the SSL tab The SSL tab configuration fields are displayed Figure 26 gt iChip Configuration
26. ct the Set Power Save Mode PSE checkbox to enable the power save mode in which iChip automatically shuts down most of its circuits after a period of n seconds without any activity on the host or modem serial ports Renewed activity on the serial ports restores iChip to full operational mode In the Service Disable Mask SDM area Select the PING Reply checkbox to prohibit iChip from responding to PING requests this can protect against PING attacks Select Remote Debug checkbox to disable the remote debugging feature Select the Unauth Web Server checkbox to prohibit unauthenticated viewing of the iChip internal website Select Disable SNET Escape with to prohibit exiting SerialNET mode when the Escape sequence is detected Select Disable Break Reset to support use of the Break signal for exiting SerialNET Deselect this flag to use Break to reset iChip and reboot into SerialNET mode Select Disable Internal Config Site to prohibit browsing to iChip s internal Configuration Web site Page 24 of 70 Connect One iChip Config Utility User Manual 49 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears Configuring th
27. displayed Figure 20 Page 27 of 70 Connect One iChip Config Utility User Manual gt iChip Configuration tools File Search Parameter Wireless LAN Remote Few First phone number ISP1 Authentication method ATH PAP Second phone number ISP2 Max redial trials RDL 5 User name USRN Wait time before redialing RTO 180 Password PWD iChip type C02144 D iChip plus LAN platform Firmware ver D809b15 5 4 2012 Serial num 14001040 Boot block 0801 9 6 2009 Close Port COM12 Baud Rate 115200 Figure 20 ISP Connection Tab of Full Configuration Tool 2 In the First Phone Number and Second Phone Number fields ISP1 and ISP2 type the main and alternate phone numbers you use to connect to your ISP Include any required area codes and outside line access numbers Use a comma to create a dialing delay For example if you need to dial a 9 for an outside line type 9 nnnnnnn where n digits of the dialed phone number In the User Name USRN field type your username as defined by your ISP In the Password PWD field type your password as defined by your ISP From the Authentication Method ATH dropdown list select the authentication method supported by your ISP Script PAP or CHAP 6 In the Max Redial Trials RDL field type the number of redial attempts for each ISPn 7 Inthe Wait Time Before Redial RTO field type the value in seconds of the time interval between redial att
28. down list select a value for Internet session initiation mode mostly applicable for work with a modem Select from the following Disabled Disables iChip from initiating a triggered Internet session Enabled Sets iChip to initiate Internet sessions in response to a defined trigger Such as a RING signal detected on a modem Always Online Sets iChip to remain online continually without any trigger to initiate the session From the Modem Interface MIF dropdown list select the Interface over which the iChip will connect to a dialup or cellular modem Page 22 of 70 Connect One iChip Config Utility User Manual 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 In the A2D detect threshold ADCL field specify the A D level 0 255 which is the center of the A D hysteresis window In the A2D detect period interval ADCT field specify the time interval in milliseconds between A D quieries In the A2D detect threshold delta ADCD field specify the A D hysteresis window size defined as ADCL ADCD In the A2D detect GPIO pin field specify the pin that will be toggled when the A D level crosses the hysteresis window Specify 0 to disable signaling A value of 1 6 corresponds to pins PIOC 0 5 The signal will be set HIGH when when crossing over to ADCL ADCD and set LOW when crossing below ADCL ADCD In the SPI Control Signal SPIP field spe
29. e DPSZ PING Destination 2 PDS2 0 Mailbox password MPWD DHCP Server Lease Time DSLT Proxy Server IP Port fo Multiple Platforms Parameters Additional Params for simultaneously Multiple LAN interfaces Primary domain names server LAN DNS1L Primary domain names server Ethernet DNS1E Outgoing mail server LAN SMTPL OD 0 0 O 0 0 O 0 Secondary domain names server LAN DNS2L Secondary domain names server Ethernet DNS2E Incoming mail server LAN POP3L 0 0 0 0 fo 0 0 0 NT miele ela Primary domain names server WIFI DNS1W Outgoing mail server Serial SMTPS 0 0 0 0 0 0 0 0 Mer MN Je SE Secondary domain names server WIFI DNS 2w Incoming mail server Serial POP3S 0 0 0 0 0 0 0 0 iChip type C02144 D iChip plus LAN platform Firmware ver D809b155 4 2012 Serial num 14001040 Boot block 0801 9 6 2009 Close O Ready Port COM12 Baud Rate 115200 Figure 15 Sever Profiles Tab of Full Configuration Tool Page 19 of 70 Connect One iChip Config Utility User Manual 2 To keep a copy of retrieved emails on the server select the Leave copy on server checkbox If the checkbox is not selected retrieved emails are deleted In the Primary Domain Name Server DNS1 and the Secondary Domain Name Server DNS2 fields type the IP addresses of the DNS servers you want to use to resolve logical server names into IP addresses for working in LAN mode with a fixed IP address I
30. e LAN Tab This procedure describes how to configure parameters for working in a LAN environment What you need Access to the Configuration Tools window as described in Section 3 3 1 How 1 In the Configuration Tools window click the LAN tab The LAN tab configuration fields are displayed Figure 17 gt iChip Configuration tools File Search Parameter Remote FW ISP Connection Remote params update Email format Server profiles Operational i Additional LTYP 4 parameters MAC address MACA Default IP address DIP Ethernet Default IP address EDIP FFO000000000 lo 0 0 0 Q 2 0 Ethernet Gateway IP EIPG Assigned IP address IPA Use DHCP 0 0 0 0 Use IP Finder Ethernet Subnet Mask ESNT 0 O O O Sub Net address SNET O S0 0 20 Gateway IP address OD 0 20 30 iChip type C02144 D iChip plus LAN platform Firmware ver D809b155 42012 Serial num 14001C40 Boot block 0801 9 6 2009 Baud Rate 115200 Figure 17 LAN Tab of Full Configuration Tool 2 Determine whether you are working with a DHCP server or in fixed IP address mode a To work in DHCP mode Select the Use DHCP checkbox Set the values of the Default IP Address Subnet and Gateway fields to 0 Page 25 of 70 Connect One iChip Config Utility User Manual b To work in fixed IP address mode In the Default IP Address field type the IP address for the iChip In the Subnet field type the subnet
31. e loaded successfully comes o General Settings Baud rate 115200 Scan Operations Fw Update Memory Dump Dump Memory to file Exit Monitor mode Page 43 of 70 Connect One iChip Config Utility User Manual 12 In the dialog box that appears browse to the location of the firmware IMF file you obtained from Connect One select the file and click Open a 21 x Look ir I Dual i e Size Type a spres imf 466 KB IMF File jel28d721g01 imf i 475KB IMF File B 21 28d721GOICF i imf 438 KB IMF File a i2128d721q01W24 imf 472KB IMF File 28 i2128d721901WSMT imf 437 KB IMF File i661d721902 imf 235 KB IMF File 66 1d721902ROUT imf 226 KB IMF File i210d721902 imf 265 KB IMF File pl liz11d721902 imf 317KB IMF File a File name i21 284721 q0 im Files of type fan files Cancel Open as read only My N ae a 13 Click Yes when prompted x re you sure you want to send File 11172 20 0 1 11DevtImodemlimfbualiz128d721901 im 14 The following window appears while the firmware is being installed on the flash eee Writing to address 10027800 0x400 words Time Elapsed 00 00 16 Total Size 0476800 Cancel 15 OK the dialog box that appears when installation has completed successfully x Image file loaded successfully 16 Click the Exit Monitor Mode button on the Monitor Mode window to return to command mode Updating Existing Firm
32. eaches this exact number of bytes the buffered content is sent as a packet Timeout iChip waits the defined time interval in milliseconds then sends the buffered content as a packet How 1 After you complete the connection initiation configuration Section 4 3 2 and click Next the Flush Condition Parameters area appears Figure 48 gt SerailNET Getting started Wizard Flush condition parameters Do you terminate each transmission with a fired Char String C Yes Enter string here Do you use fixed amount of bytes for each transmission amp Ho C Yes Enter amount here Cancel Figure 48 SerialNET Getting Started Wizard Flush Condition Parameters 2 Inthe Transmission Termination area do one of the following m If you do not use a termination character in your transmissions select No m If you use a fixed termination char select Yes and then type the ASCII value character in the indicated field i If you chose No iChip is configured with a default timeout interval of 100 milliseconds 3 In the Fixed Bytes per Transmission area do one of the following m If you do not fix the number of bytes per transmission select No m If you use a fixed number of bytes for every transmission select Yes and then type the number of bytes in the indicated field I To configure multiple parameters for flush conditions use the Full Configuration tool Section 3 3 Page 61 of 70
33. ed all the information to setup SenalNET mode Press Finish to save and exit or Cancel to exit without W Constantly connected to the Internet View Settings Back Finish Cancel Figure 55 SerialNET Getting Started Wizard Completing Configuration 2 To view the settings defined in the wizard click View Settings The General Viewer window appears displaying communication platform settings information To save the settings and exit the wizard click Finish The settings are saved and the SerialNET Wizard closes Page 66 of 70 iChip Config Utility User Manual Connect One iChip Config Utility User Manual Page 67 of 70 Connect One iChip Config Utility User Manual Working with iChip Config over a USB Connection You can work with the iChip CO2128SEC CO2064SEC using the iChip Config Utility over a USB connection To enable this feature you need to install a USB driver supplied by Connect One on a PC running Windows XP OS This driver installs a USB device that appears as a modem to the Windows XP operating system Although the device is connected via a USB interface it appears as if connected via a virtual COM interface and a new COM port number is assigned to this connection The USB driver is supplied as two separate files sabalo inf and usbser sys To install the USB driver 1 Copy sabalo inf to C WINDOWS inf To view the inf directory you must allow viewing of hidden folders in Folder Option
34. eld 6 UF06 User Field 12 UF12 iChip type C02144 D iChip plus LAN platform Firmware ver D809b155 42012 Serial num 14001040 Boot block 0801 9 6 2009 Close Figure 25 User Fields Tab of Full Configuration Tool 2 In each User Field UFn field type the desired value 3 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 13 Configuring the RAS Tab This procedure describes how to configure remote access server RAS fields which enable you to dial into the iChip A What you need Access to the Configuration Tools window as described in 3 3 1 C7 How 1 In the Configuration Tools window click the RAS tab The RAS tab configuration fields are displayed Figure 26 Page 35 of 70 Connect One iChip Config Utility User Manual gt iChip Configuration tools File Search Parameter Wireless LAN Remote Few Email format Serial NET RAS User Name RAU RAS Password RAP RAS Rings RAR 4 iChip type C02144 D iChip plus LAN platform i 1D809b15 5 4 2012 Serial num 14001040 Boot block 0801 9 6 2009 Close a Ready Port COM12 Baud Rate 115200 Figure 26 RAS Tab of the Full Configuration T
35. elect the file and click Open JE 2 i2128d721901PX02 imf IMF File History i2128d721q01 imf IMF File 21200721001 IN E 8 i2128d721901CF imf IMF File m i2128d721901W24 imf IMF File Desktop sm i2128d721901WSMT imf IMF File 72 la i661d721q02 imf IMF File ee an i661d721902ROUT imf IMF File My Documents ja i210d721q02 imf IMF File i211d721q02 imf IMF File M ee ita File name i2128d721 901 imf v EE Files of type fan files My Network P I Open as read only 6 Click Yes when prompted ichieconig x re You sure you want to send File 11172 20 0 1 11DevtImodemlimf0ualiz2128d721901 im 7 The following window appears while the firmware is being installed on the flash ial meme Writing to address 10027800 0x400 words Time Elapsed 00 00 16 Total Size 0476800 Cancel 8 OK the dialog box that appears when installation has completed successfully ichipconfig ES Image file loaded successfully 9 Click the Exit Monitor Mode button on the Monitor Mode window to return to command mode Page 46 of 70 Connect One iChip Config Utility User Manual gt To view iChip memory information on your monitor a Click Memory Dump The Memory Dump window appears Figure Error Bookmark not defined Memory Dump Address Hex Size Hex ee Max Packet Size Hex 400 Cancel Figure 28 Memory Dump Window b Type values in the field
36. empts 8 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears Page 28 of 70 Connect One iChip Config Utility User Manual 3 3 8 Configuring the Remote Params Update Tab This procedure describes how to set a password for remote parameter updating The remote update password RPG functions as follows If an RPG is not set field is blank remote firmware updates are disallowed and Web parameters cannot be set via a Web browser m Ifthe RPG is set to iChip allows remote updating without password authentication m Ifthe RPG is defined to any other value the user must submit that exact value to perform remote updates A What you need Access to the Configuration Tools window as described in 3 3 1 G How 1 In the Configuration Tools window click Remote Params Update tab The Remote Params Update tab configuration fields are displayed Figure 21 gt iChip Configuration tools Fie Search Parameter Remote update password RPG iChip type C02144 D iChip plus LAN platform Firmware ver D809b155 42012 Serial num 14001C40 Boot block 0801 9 6 2009 Close EEE Ready Port COM12 Baud Rate 115200 Figure 21 Remote
37. er user name UUSR Firmware update server password UPWD a inactive Platform Parameters _ _ v_ rvv s v iChip type C02144 D iChip plus LAN platform i 1D809b15 5 4 2012 Serial num 14001C40 Boot block 0801 9 6 2009 Close 7 Z Ready Part COM12 Baud Rate 115200 Figure 19 Remote FW Tab of Full Configuration Tool 2 Select the Enable Fallback Update checkbox to enable an update to an older version of the iChip firmware 3 In the Firmware Update Server USRV field type the name and directory of the update file location 4 If the file is in an FTP directory type the username and password in the UUSR and UPWD fields 5 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 Configuring the ISP Connection Tab This procedure describes how to configure parameters for working in a dialup environment z What you need Access to the Configuration Tools window as described in Section 3 3 1 LG How 1 In the Configuration Tools window click the ISP Connection tab The ISP Connection tab configuration fields are
38. et of features and parameters You only have access to the features applicable to your product For example when configuring an iChip with only LAN support parameters relating to dial up and wireless modem are grayed out Page 7 of 70 Connect One iChip Config Utility User Manual 2 Getting Started m Installing iChipConfig Utility m Accessing iChipConfig Utility Tools 2 1 Installing the iIChipConfig Utility This procedure describes how to install the iChipConfig utility on your local workstation so you can configure the iChip firmware or upload Web pages or parameter files z What you need m iChip Config installation ZIP file downloaded from www connectone com C7 How 1 Extract the contents of the ZIP file to a temporary folder in your local directory for example C Temp 2 Double click setup exe 3 The iChipConfig Setup window appears Figure 2 2 iChipConfig Setup ep Welcome to the iChipConfig installation program Zoe Setup cannot install system files or update shared files if they are in use Before proceeding we recommend that you close any applications vou may be running Exit Setup Figure 2 iChipConfig Setup Window 4 Click OK The iChipConfig Setup window refreshes displaying the default installation directory Figure 3 Page 8 of 70 Connect One iChip Config Utility User Manual 2 iChipConfig Setup X Begin the installation by clicking the button below Click
39. f you are working in DHCP mode or using IP addresses and not logical names leave these fields blank I On iChip Plus DNS1 DNS2 SMTP and POP3 have two sets of parameters 10 11 one for the current communication platform and one for the inactive communication platform In Figure 15 iChip Plus is configured to use the dialup communication platform so the inactive communication platform should be defined with the LAN values for DNS1 and DNS2 In the Outgoing Mail Server SMTP field tyoe the name or IP address of the outgoing SMTP mail server In the Incoming Mail Server POP3 field type the name or IP address of the incoming POP3 mail server In the Mailbox User Name MBX and Mailbox Password MPWD fields type the username and password you use to access the mailbox If you specify an SMTP server that requires user authentication in the Outgoing Mail Server SMTP field you need to select the SMTP Authentication SMA checkbox and enter appropriate strings in the User Name SMU and Password SMP fields In the DHCP Server Pool Size DPSZ field enter an integer between 1 and 255 to activate iChip s internal DHCP server and set the number of IP addresses to be allocated in its IP pool In addition enter an integer between 0 and 65535 to define the lease time in minutes to be granted by iChip s DHCP server when assigning IP addresses to clients A lease time value of 0 means indefinite lease In the Ping P
40. from the factory defaults Check and define a GROUP password to restrict RPF update to iChips that have their RPG field set to the same GROUP password Check and define Destination Chip Serial Number to restrict RPF update only to a specific iChip with this serial number e Search for Parameter Use this menu option to search for a parameter The following dialog is displayed iChipConfig Type in the parameter name and click OK Page 40 of 70 Connect One iChip Config Utility User Manual 3 4 Working with the iChip Uploader via Serial Tool This procedure describes how to upload iChip s firmware and perform other operations via the serial host interface using the Uploader tool abg z What you need m Device or module using Connect One iChip or Connect One II EVB board connected to your workstation with power on LGF How 1101 0010 1011 0001 0110 1 Inthe iChip Configuration Tools window click the iChip Uploader mwa icon 2 Perform the desired upload actions to your iChip step 1 3 To exit the iChip Uploader tool click either Close or Exit 3 4 1 Updating Firmware for CO2128SEC Locally The I EVB 630W can be updated locally via the Tools gt CO2128 2064 Monitor Mode command or via the iChip Uploader feature of the iChipConfig Utility First time installation of the firmware must be done via Monitor Mode Successive firmware updates can be performed using the iChip Uploader which is a much faster p
41. iChip Config Utility User Manual Connect ne v 2 4 95 International Connect One Lid 20 Atir Yeda Street Kfar Saba 44643 Israel Tel 972 9 766 0456 Fax 972 9 766 0461 http www connectone com USA Connect One Semiconductors Inc 560 S Winchester Blvd Suite 500 San Jose CA 95128 Tel 408 572 5675 Fax 408 572 5601 Connect One iChip Config Utility User Manual Notice The information in this document is subject to change without notice and shall not be construed as a commitment on the part of Connect One Connect One assumes no liability for any errors that might appear in this document The software described in this document is furnished under a license agreement and may be used or copied only in accordance with the terms of such a license agreement It is forbidden by law to copy the software on any medium except as specifically allowed in the license agreement No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical including but not limited to photocopying recording transmitting via fax and or modem devices scanning and or information storage and retrieval systems for any purpose without the express written consent of Connect One iChip iChip LAN Socket iChip Embedded iModem Internet Controller iLAN 100 iLAN iWiFi iConnector iConnectorLE iModem Nano WiReach Nano LANReach I EVB AT i Instant Internet and Connect One are trademar
42. igure 27 Wireless LAN Tab of Full Configuration Tool 2 In the General WLAN Parameters group a From the Wireless LAN Channel WLCH dropdown list select the iChip communications channel to be used when creating an Ad Hoc network b From the Security Type WSEC dropdown list select the default WPA or WPA2 security to use c In the Power Save WLPS field specify the number of beacon periods during which the WiFi chipset remains in Power Save mode before scanning for the next Beacon Define a 0 value to disable WiFi Power Save mode d From the Roaming Mode dropdown list Disable or Enable Wireless LAN Roaming Roaming mode is used to transfer between AP s without obstructing an ongoing connection e Inthe WLAN Lo SNR TH WSLR field specify the threshold value in percent below which iChip will start searching for a new AP to roam to f Inthe WLAN Hi SNR TH WSLH field specify the threshold value in percent above which iChip will roam to a new AP g In the Periodic Scan Interval WPSI field specify the time interval in seconds between consecutive scans that iChip will perform in search for APs in its vicinity h In the Access Point BSSID BSID field specify the BSSID of the specific AP to connect to AP BSSID is the AP MAC address Page 37 of 70 Connect One iChip Config Utility User Manual i Inthe Enterprise Domain User EUSN field specify the Domain and User name to use when connecting to a WLAN i
43. ion File CAWINDOWS system32 RICHEDS2 DLL ie soo Figure 6 IChipConfig Setup Progress Bar When the progress bar reaches 100 a dialog box appears indicating successful installation iChipConfig Setup x iKhipConfig Setup was completed successfully Figure 7 Successful iChipConfig Installation Message f Click OK The iChipConfig utility is now installed on your workstation Page 10 of 70 Connect One iChip Config Utility User Manual Accessing IChipConfig Utility Tools This procedure describes how to open the iChipConfig Utility set the correct baud rate and use the utility to configure or send information to the iChip What you need m Device or module using Connect One iChip or Connect One II EVB board connected to an RS232 COM port or USB port on your workstation with power on How 1 From the Start menu select Programs gt ConnectOne gt iChipConfig The iChip Configuration Tools window appears Li L L L I i gt iChip Configuration tools E BIK File Tools Wizards Host lt gt iChip options Serial Ports SerialNET Options Help Connect ne Click on the desired operation icon Quick Configure Site Pack Send Email Script Tool attachment E iChip site Uploader Receive Email Change iChip via HTTP plus platform iChip Uploader Dumb Terminal Get URL via serial 1101 0010 1011 0001 01101111 0111 0010 Full Configuration Port COM1 Baud Fate 115200 Figure 8 IChi
44. is screen you can enter the baud rate number of data bits type of parity number of stop bits and flow control type IP Registration iChip might be connected to a device that is assigned a dynamic IP address To help the remote server know which devices are online and the IP address of each device iChip can publish its unique host name currently assigned IP address and port through email or socket registration After you finish setting the serial parameters as described in section 4 3 4 and click Next the IP Registration window of the SerialNET Wizard appears Figure 51 Page 63 of 70 Connect One iChip Config Utility User Manual gt SerailNET Getting started Wizard Do you want to publish your IP address and device name to the remote side or 3rd party Back Hext Cancel Figure 51 SerialNET Getting Started Wizard IP Registration 1 If you want to publish your IP address to the remote server or to a 3rd party select Yes The following options appear Figure 52 SerailNET Getting started Wizard Do you want to publish your IP address and device name to the remote side or 3rd party C Ho Yes How would you like to publish your IP address and device name C Via Socket Back Next Cancel Figure 52 SerialNET Getting Started Wizard IP Registration Options Select either Via Email or Via Socket If you select Via Email the Email Registration Parameters wind
45. ket connection 8 Inthe Port Settings for SerialNET SNSI field type the values for the baud rate number of data bits parity and stop bit for iChip in SeriaINET mode Use the format lt baud gt lt data bits gt lt parity gt lt stop bits gt lt flow gt 9 In the Max Bytes to Buffer MBTB field type the value of the maximum number of bytes for iChip to buffer while waiting to establish an Internet connection 10 From the Socket Type STYP dropdown list select either UDP or TCP as the destination socket type 11 In the Server SerialNET Port LRPT field type the number of the listening port for the SerialNET server 12 In the IP Address to Connect to HSRV field type the port server name or IP address for iChip to locate and connect to when serial data is transmitted from the device 13 In the Alternate IP Address to Connect to fields HSR1 and HSR2 type alternate port server names or IP addresses for iChip to connect to if HSRV is nonresponsive 14 In the Serial Phone Number SPN field type the phone number to use to wake up a remote SerialNET server 15 In the SerialNET Dialup Timeout SDT field type the value in seconds of the time interval to elapse for iChip to cease attempting to wake up a remote SerialNET server via dialup 16 In the Packets to Drop PTD field type the filtration ratio factor value to determine how many of the packets iChip generates are sent to the host For example if the
46. ks of Connect One Ltd Copyright 2000 2012 Connect One Ltd All rights reserved Page 2 of 70 Connect One iChip Config Utility User Manual Table of Contents 1 2 3 Node 6 1 1 IChip Config Utility OVErViGW cccccccccccssssseeceeeeeeeseeesseceeeeeeseeeaeseeeeeeessaeaaeeeeeeessaengeess 6 1 2 STE Ea 16 11 11100151 EE 6 1 3 Quick Tour of the iChip Config Utility rrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 6 1 3 1 IChipConfig Utility Menus rrnrrnnrrrnrrrnnnnnnnnvrvnnrrnnnnnnnnsrnnnnnnnnnnnnnssnnnnnnnnnnssesnnnnnnnnnn 6 1 3 2 iChip Config Utility Functionality rrrrrrrrrrnnnnnrnnrrnrrrrnnnnnnnrvrnnrrnnnnnnnnnrrnnnrnnnnnnnnneenn 7 Gening SETE Lee 8 2 1 Installing the iChipConfig Utility ec cccccccesssseeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeesseeaeeeeeeeeeaaas 8 2 2 Accessing iChipConfig Utility Tools ccccccccccseseeeeeeeeeeeeeeeeeeeeeeeeeeaeeseeeeeeessuaeseeeeeees 11 Working with IC IT COMMING saadan eek 13 3 1 IChipConfig Tools OVErVieW csceceecccceeeceeeeeeeeeeeeeeeeeeeeeeeeeeeesaeeeeeeeeeesseaaaeeeeeeeeessaaas 13 3 2 Quick Configuration Luvvervesssevsesesvsansen rtujvovenatrddddipdunniseed 13 3 2 1 Quick Configuration Tool Overview rrrrrrvvrrrrrrrrrrnnnnnnnnnnnnnnrrvrrrnnnrrrnnnnnnnnnnnnnnnnnnnee 13 3 2 2 Working with the Quick Configuration Tool cccccceeeeeeeeeeeeeeaeeeeessseeeeeeeeeeeees 13 3 3 Full Config
47. media subtype of the email attachment 15 In the Attachment File Name FN field type the attachment filename including the extension For example filename jpg 16 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 3 Configuring the Server Profiles Tab This procedure describes how to configure parameters for incoming and outgoing mail servers and mailbox settings What you need Access to the Configuration Tools window as described in Section 3 3 1 C7 How 1 In the Configuration Tools window click the Server Profiles tab The Server Profiles tab configuration fields are displayed Figure 15 gt iChip Configuration tools File Search Parameter Remote FA ISP Connection Remote params update am Email format Server profiles Operational un IV Leave copy on server Outgoing mail server SMTP SMTP Authentication SMA PING Polling Frequency PFR Primary domain names server DNS1 SMTP Port SP User Name SMU 0 Oo 20 20 30 25 P PING Destination 1 PDS1 EE ETE ENDE nod Incoming mail server POP3 Password SMP ic 20 20 20 Mailbox user name MBX DHCP Server Pool Siz
48. n Enterprise mode via RADIUS server j Inthe Enterprise Password EPSW field specify the Password to use when connecting to a WLAN in Enterprise mode 3 Inthe WLAN SSID group a Inthe Wireless LAN SSID WLSI field type the value string of the major AP system set ID SSID When specifying an Ad Hoc system prefix the SSID string with an mark b Inthe SSID WSI fields specify additional fall back SSID strings If a connection to the AP according to WLSI is not successful iChip will scan through the SSID list until a successful connection is made 4 Inthe WEP Parameters group a From the Wireless LAN WEP Mode WLWM dropdown list select the wired equivalent privacy WEP mode to work with in the wireless LAN environment b From the Wireless LAN Key Index WLKI dropdown list select the WEP key index value to use to transmit WiFi packets c In the Wireless LAN Key WLKn fields 1 4 type a key value hexadecimal string to define the WEP key array in a WEP secured wireless LAN environment as defined in the WLWM parameter step 4 The WEP key array is used to encrypt outgoing packets using the key defined in the WLKI parameter step 5 and decrypt incoming packets The identical value must be configured in the same position in the AP router 5 Inthe WLAN Security Type group a From the Security type WST dropdown list select the type of security required for each AP whose SSID is specified in the
49. n Platform Wizard rrrnnrrnnnrrnnnnnnnnornnnrrnnnnnnnnnnnnnnnnnnn 53 4 2 2 Configuring Dialup or GSM Parameters rrrrrnnnnrrrrvvvnrrrnnnnrrrrrrnnnrnnnnnerrernnrrnnnnsnnnee 54 42 5 Gontiguring GPRS Parameters aiiictiec tesreocieodossteverseunevtesetetadeoss elatna iei 55 424 Gontiguring LAN Settings si2 c2 cucedscosssucexsaszasccosssetocasshes cosasaaescadzcbsacdaesgecsodsseieccanace 55 4 2 5 Viewing and Completing Communication Platform Configuration ccce 56 4 3 SenalNET Configuration WZardsaravvd2svsrvv Te 58 4 3 1 Starting the SerialNET Configuration Wizard r rrnnnrnnnrrnnrrnnnnnnnnnrnnnnrnnnnnnnnennnnnnnnnn 58 4 3 2 Configuring CONNECTION Initiation rrrrrrrrrrnnnnrrnrvrrnvrrnnnnnnnrrrnrrnnnnnrnsrennnrnnnnnsnneee 58 4 3 3 Setting Flush ConditiOns rrrrnnnrrnnnnnnnnnvvvnrrrnnnnnnnrvrnnrnnnnnnnsernnnrnnnnnnnnssennnnnnnnnnnnsee 60 4 3 4 Configuring the Host Interface rrnnrrrnnrrrnrrrnnnnnrnrvrnnrrrnnnnnnnrrnnrrnnnnnnnssennnrnnnnnsnnnee 62 4 3 5 Configuring Serial Settings 00 cccccccesscceeseeececeecsccceneceeeesecceesseeesetessscceseneeeess 62 230 PREG vasene 63 4 3 7 Viewing and Completing SerialNET Configuration cccccccssseeseeeeeeeeeseeeeeeeeeees 66 6 Working with iChip Config over a USB ConnectiOn xnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnr 68 7 GIOSS AY na 69 Page 4 of 70 Connect One iChip Config Utility User Manual Preface
50. nnection After a connection is established both the device and the remote server have full duplex TCP connection available until one of the devices is disconnected or ends the session Fj How Page 58 of 70 Connect One iChip Config Utility User Manual 1 Inthe First Connection area do one of the following m If your device transmits data without a specific request a Select Yes The Remote Side Parameters area appears Figure 46 gt SerailNET Getting started Wizard Remote side parameters Enter remote side IP Address E per ES Enter remote side Port number EEE Cancel Figure 46 SerialNET Getting Started Wizard Remote Parameters b In the Remote Side IP Address field type the IP address of the remote server for iChip to contact c In the Remote Side Port Number field type the port number on the remote server for iChip to contact m f your device waits for a remote request to connect a Select No The Local Side Parameters area appears Figure 47 Page 59 of 70 Connect One iChip Config Utility User Manual SerailNET Getting started Wizard Local side parameters Please enter the Port number you want to listen on 5432 Back Next Cancel Figure 47 SerialNET Getting Started Wizard Local Side Parameters b In the Listening Port Number field type the number of the port on which iChip listens for a remote connection request You can use any number between
51. olling Frequency PFR field type a value defining the time interval in seconds at which iChip issues PING requests to one of the PING destination servers In the Ping Destination 1 and Ping Destination 2 fields PDS1 and PDS2 type the names or IP addresses of the primary and secondary PING destination servers Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears Configuring the Operational Parameters Tab This procedure describes how to configure parameters for general operations What you need Access to the Configuration Tools window as described in Section 3 3 1 Page 20 of 70 Connect One iChip Config Utility User Manual CS How 1 In the Configuration Tools window click the Operational Parameters tab The Operational Parameters tab configuration fields are displayed Figure 16 gt iChip Configuration tools File Email format Server profiles Search Parameter Extended return code XRC 4 No Blind Dial Blind dial Modem initialization string MIS AT amp FEOVIX4008D2M1L3 Modem type designator MTYP Standard Modem v Suppress ATZ Wait time constant WTC 45 TCP timeout TTO 0 Inactivity timeout IATO
52. on v Address description TO Media subtype string MST Return Email address REA Attachment file name FN Sender description FRM iChip type C02144 D iChip plus LAN platform Firmware ver D809b15 5 4 2012 Serial num 14001C40 Boot block 0801 9 6 2009 Close Port COM12 Baud Rate 115200 Figure 13 Email Format Tab of Full Configuration Tool 2 Toretrieve email headers together with the email body select the Transmit Email Headers XFH checkbox 3 Inthe Limit Number of Headers HDL field type the maximum number of header lines for the host to retrieve leaving the field blank or typing 0 configures the default value that enables retrieval of all sent headers 4 Inthe Filter String FLS field type a string word or phrase ASCII format by which to filter emails retrieved from the server iChip only retrieves emails containing the defined string in the header lines 5 Inthe Subject SBJ field type the word s you want to appear in the subject line of the email 6 In the Email Address TOA field type the email address to which you want to send an email 7 To define a mailing list of up to 50 email addresses click 50 Addressee The 50 Addressee window appears Figure 14 Page 17 of 70 Connect One iChip Config Utility User Manual 50 Addressee TOAIn address 01 U2 03 04 OG OG OF Og 05 10 11 12 q3 namel domain com hame2 domain com nametsdomaln com
53. ool In the RAS Username RAU field type the username used to access the RAS In the RAS Password RAP field type the password used to access the RAS In the RAS Rings RAR filed type the number of rings after which the RAS allows the connection 5 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 14 Configuring the Wireless LAN Tab This procedure describes how to configure wireless LAN communication parameters a What you need Access to the Configuration Tools window as described in 3 3 1 CS How 1 In the Configuration Tools window click the Wireless LAN tab The Wireless LAN tab configuration fields are displayed Figure 27 Page 36 of 70 Connect One gt iChip Configuration tools iChip Config Utility User Manual File Search Parameter i Wireless LAN General WLAN Parameters WLAN SSID WLAN Channel WLCH Power Save WLPS nn aa belkinbdg D v 0 Security Type WSEC WLAN Lo SNR TH WSLR SSID1 WSI1 0 WPA vj 120 Roaming Mode WLAN Hi SNR TH WSRH SSID2 WSI2 0 Roaming Disable v 30 Access Point BSSID BSID Periodic Scan Interval WPSI SSID3 W513 000000000000 5 Enterprise User EUSN Ad Hoc scan W
54. ools window click the IP Registration tab The IP Registration tab configuration fields are displayed Figure 24 gt iChip Configuration tools File Search Parameter Serial NET IP registration RAS Server address to Register RRSV Email address to Register RRMA Web Server URL to Register RRWS Return Link to Register RRRL iChip type C02144 D iChip plus LAN platform i 1D809b15 5 4 2012 Serial num 14001040 Boot block 0801 9 6 2009 Close Ready Port COM12 Baud Rate 115200 Figure 24 IP Registration Tab of Full Configuration Tool 2 In the Server Address to Register RRSV field type the name or IP address of the ring response server and port number with which iChip establishes a connection in response to a RING detected on the modem The IP address dynamically assigned to iChip by the ISP and the LPRT listening port are sent to the server and then the socket is closed 3 In the Email Address to Send IP RRMA field type the email address of the recipient of notification email messages sent after iChip establishes a connection to the ISP in response to a RING detected by the modem Page 33 of 70 Connect One iChip Config Utility User Manual The email notification message includes the IP address dynamically assigned to iChip by the ISP and the LPRT listening port 4 Inthe Ring Response Web Server URL RRWS field type the URL of the ring response Web server to use for dynamic regi
55. ow appears Figure 53 4 Complete fields Page 64 of 70 Connect One iChip Config Utility User Manual gt SerailNET Getting started Wizard Email Registration parameters SMTP Server Return Email address Hing Response Email Addr Back Next Cancel Figure 53 SerialNET Getting Started Wizard IP Registration by Email 5 If you select Via Socket the Socket Registration Parameters window appears Figure 54 gt SerailNET Getting started Wizard Socket Registration parameters Ring Response Server Name Hing Resposne Server Port Back Next Cancel Figure 54 SerialNET Getting Started Wizard IP Registration via Socket Complete fields 7 Click Next The Finish View Settings area appears Figure 55 8 Continue with Viewing and Completing Serial NET Configuration Page 65 of 70 4 3 7 Connect One Viewing and Completing SerialNET Configuration After the SerialNET parameters are defined you can instruct iChip to go into SerialNET mode either immediately or at a later time You can also instruct iChip to always remain online This is especially useful with GPRS communication which may intermittently disconnect CS How After you click Next in the registration window of the wizard the Finish View Settings area appears Figure 55 gt SerailNET Getting started Wizard Finished setting SenalNET configuration The Wizard has gather
56. p Configuration Tools Window 2 Click the icon of the tool you want to use The first time iChipConfig is invoked it attempts to locate the iChip connected to the PC s COM port at the default baud rate of 9600 If the utility finds the chip the tool window for the selected function appears Continue with the relevant procedure for the tool see Chapter 3 Working with iChipConfig If the utility cannot find the iChip the Serial Settings window appears Page 11 of 70 Connect One iChip Config Utility User Manual Serial Settings Serial Port Baud Rate COHM1 hl 57600 ed Select Port and BaudF ate settings A BOO 115200 256000 Figure 9 Serial Settings Window 3 From the Serial Port dropdown list select the COM port on the PC to which the iChip is connected 4 From the Baud Rate dropdown list select the baud rate used by the iChip If you do not know the baud rate select Scan If Scan is selected iChipConfig runs through the various baud rates until it finds the correct one application like Palm HotSync is not holding the port or switch to a different COM port on the PC and scan again After iChipConfig finds the baud rate you can easily change the baud rate by clicking Serial Ports on the main page menu bar and selecting the desired baud rate A If the iChipConfig utility still fails to find iChip make sure that an open Page 12 of 70 3 1 3 2 3 2 1 3 2 2 Connect One iChip Config Utili
57. rnnnnnnnnnee 34 3 3 13 Configuring the RAS Tab rrnnennnrrnnnnnnnnnvnnnnrnnnnnnnnsrnnnnnnnnnnnsnnnnrrnnnnnnnnssnnnnnnnnnsnnsee 35 3 3 14 Configuring the Wireless LAN Tab rnnnnnnrnnnnrnnnnnnnnrrnnnrrnnnnnnnnrrnnnrnnnnnnnsrnnnrnnnnnsnnnee 36 3 3 15 Configuring the SSL Tab rrrrnnrnnrrrnnnnnnnnnvnnnrrnnnnnnnnsrnnnnnnnnnnssrnnnrrnnnnnnnssennnnnnnnnsnnsee 39 3 3 16 Using the Full Configuration Menu rrrnnnnrrnnnnnnnnnvvvrnnnnnnennrnnnnnnennrnnnnennrnnnnnsrnnnnnnsnee 40 3 4 Working with the iChip Uploader via Serial Tool rrrrnnnnnnnnnnnnrrnnvennnrnnnnnnrnerennnnnnnnnnee 41 3 4 1 Updating Firmware for CO2128SEC Locally rrrnnnnnnnnnrrnnnnnvvvvnnnnnnrrrrrnnnnnnnennnennn 41 First Time Firmware Installation Using Monitor Mode arnnnnnnnnnnnnnnnnnnnnrrnnnnnnnnnnnnnrrnnnnnnennnnnn 41 Updating Existing Firmware Using the iChip Uploader cccccecccssseeeeeeeeeeeeeeeeseeeeeeeeaaas 44 3 5 Working with the Site Packer Tool rrrrrrnnnnnnnnrnnnrrrnnnnnnnnrnnnrrnnnnnnnrnnnvnnnnnnnnnsrennnnnnnnnnnnee 48 Page 3 of 70 Connect One iChip Config Utility User Manual 3 6 Working with the iChip Uploader via HTTP Tool ccccccccssseeeeeeeeeseeeeeseeeeeeeeenees 49 3 7 Working with the Dumb Fem av SeNe 51 4 Wiza S is a a a aa a a aa 53 4 1 Wizards ENN 53 4 2 Communication Platform Wizard rrnnnrnnrrrnnnnnnnrvrnrrrnnnnnnnnrvnnnnnnnnnnssrnnnnnnnnnnnsssrnnnnnnnnnn 53 4 2 1 Starting the Communicatio
58. rocedure that does not require re installation of the boot loader First Time Firmware Installation Using Monitor Mode 1 Open the iChipConfig utility iChip Configuration tools Seles File Tools Wizards Host lt gt iChip options Serial Ports SerialNET Options Help Connect Ine Click on the desired operation icon Quick Configuration Site Pack Send Email Script Tool attachment go fr iChip site Uploader Receive Email Change iChip Full Configuration via HTTP plus platform iChip Uploader Dumb Terminal Exit la serial 1101 0010 E 1011 0001 ai 0110 1111 HE 0111 0010 a Part COM12 Baud Hate 115200 2 Click Tools gt CO2128 2064 Monitor Mode Page 41 of 70 Connect One iChip Config Utility User Manual 3 In the dialog box displayed select EBI Flash 16 Megabit for 2Mbyte Flash option and click OK Choose Flash Type Flash Types f SPI Flash 4 Megabit C EBI Flash 8 Megabit 512 K x16 bit bottom co EBI Flash 64 Megabit 4 M 16 bit OF Cancel 4 Recycle power to the II EVB 630W while holding down the Mode Select MSEL switch for at least 5 seconds and click OK to continue x Please recycle power ta iChip while holding the Mode Select switch For at least 5 seconds Click OK to continue or Cancel to cancel operation i Cancel 5 The following window appears while the FPRO application is installed M O Loading FFA to iChip Time Elapsed 00 00
59. s 2 Copy usbser4 sys to C WINDOWS system32 drivers 3 Connect one end of a USB cable to your PC Connect the other end to the USB connector of the board on which the iChip CO2128SEC CO2064SEC is mounted For example to Connect One s II EVB 600 evaluation board 4 Switch on the power to the board 5 The Found New Hardware Wizard of Windows XP pops up and prompts you to install a new device driver When prompted with the message Can Windows connect to Windows Update to search for software select No not this time 6 When prompted with the message What do you want the wizard to do select Install the software automatically Recommended 7 When a pop up window reports that the software for the new hardware Connect One Saballo USB Device has not passed Windows Logo testing select Continue Anyway The USB driver is now installed and ready for use To view the properties of the new driver 1 From the Windows task click Start gt Settings gt Control Panel Double click the System icon In the dialog box displayed select the Hardware tab Click the Device Manager button Open the Modems list to find the Connect One Saballo USB Device a a YY Page 68 of 70 Connect One iChip Config Utility User Manual 7 Glossary Term Definition Access Point Name ASCII American Standard Code for Information Interchange CDPD Cellular Digital Packet Data CHAP Challenge Handshake Authentication Proto
60. s then click OK gt To dump the iChip memory to a file a Click Dump Memory to File The Dump Memory to File window appears Figure Error Bookmark not defined Dump Memory To File File to use med Address Hex Size Hex E Max Packet Size Hex 400 Cancel Figure 29 Dump Memory to File Window b In the File to Use field type the path and filename of the file to which you want to dump the iChip memory OR Click to browse and select a file c Type values in the fields then click OK Page 47 of 70 Connect One iChip Config Utility User Manual 3 5 Working with the Site Packer Tool This procedure describes how to pack a website and upload it to iChip Version 7 0x and onward support website serving as opposed to single webpage serving supported by earlier versions What you need m Device or module using Connect One iChip or Connect One II EVB board connected to your workstation with power on C7 How go 1 In the iChip Configuration Tools window click the Site Pack icon The Website Packer window appears Figure 30 Web site packer File Connect Ine Select directory Enter parameters Max Value Size Li O 47abelbJedeedSdbebddbaac 4ab2089 GJ 4dOdf3a74d8204431240985cead7 O 570bdfadel dab7abcf df7Sae705bdSe HJ 6c 46621 96cbeb730d283918e7c J a83022c0bedf2cE Fill selected parameters with value eula 1033 tut j eula 1036 tet FO eula 10
61. sor will send AT i commands 0 is Autodetect meaning that iChip will determine the Host interface as the interface where the first AT I command is received From the Bridge Mode BRM dropdown list select the required LAN to WiFi Bridge mode Specify 0 when this mode is disabled From the Baud Rate BDRM dropdown list select a value to set the baud rate at which the iChip communicates with the modem From the Fixed Baud Rate BDRF dropdown list select a value to set the baud rate at which the modem communicates with the host From the Flow Control FLW dropdown list select a flow control value No Flow Control iChip to Host Hardware Flow Control iChip to Modem Hardware Flow Control or iChip to Modem and Host Hardware Flow Control Select the Disable Reflection checkbox to disable reflection of hardware flow control signals CTS RTS DTR and DSR signal are mirrored across the iChip iChip plus by default From the Dial Mode DMD dropdown list select either Pulse or Tone dialing From the Activate Web Server AWS dropdown list select a value to set automatic iChip Web server activation Choose from the following Disabled Default value Disables automatic Web server invocation Enable Backlog n Web server is automatically activated when iChip goes online in SerialNET mode or as a result of a triggered Internet session n the maximum number of concurrent browser connections From the Triggered Up TUP drop
62. ss Sw Et Sub Net me Gateway M eS Domain Name Server Figure 41 Communication Platform Wizard LAN Parameters 2 To work with a DCHP server select Yes De To assign custom values to the iChip do the following a Select No b Type the desired values in the IP Address Subnet Gateway and Domain Name Server fields Click Next The Finish View Settings area appears Figure 42 Continue with Viewing and Completing Communication Platform Configuration Viewing and Completing Communication Platform Configuration This procedure describes how to view the communication platform configuration defined in the Communication Platform Wizard and how to complete the platform configuration and close the wizard After you click Next in the platform parameters window of the wizard the Finish View Settings area appears Figure 42 Page 56 of 70 iChip Config Utility User Manual Connect One iChip Config Utility User Manual Communication Platform Wizard Finished Setting Communication Platform The Wizard has gathered all the information to setup communication platform Press Finish to save and exit or Cancel to exit without saving View Settings Cancel Figure 42 Communication Platform Wizard Finish View Settings 2 To view the settings defined in the wizard click View Settings The General Viewer window appears displaying communication platform settings information Figure 43 General Vie
63. ss to connect to HSR1 V Send DSTR Alt IP address to connect to HSR2 Timeout before reestablishing connection SNRD Serial Phone Number SPN fo Port settings for serialNET SNSI Serial Dial Timeout SDT 58N10 20 Max bytes to buffer MBTB Packets To Drop PTD 0 0 iChip type C02144 D iChip plus LAN platform Firmware ver D809b155 42012 Serial num 14001C40 Boot block 0801 9 6 2009 Close Port COM12 Baud Rate 115200 Figure 23 SerialNET Tab of Full Configuration Tool 2 In the Character to Enforce Flush FCHR field tyoe the value you want to use to generate a TCP packet flush 3 In the Max Characters before Flush MCBF field type the number integer of characters for iChip to buffer before a TCP packet is flushed 4 Inthe Max Timeout to Flush MTTF field type the value in seconds of the time interval for iChip to wait before flushing a TCP packet Page 31 of 70 Connect One iChip Config Utility User Manual 5 In the Disconnection String DSTR field type the string to trigger iChip to complete the SerialNET session iChip closes the socket but remains in SerialNET mode iChip also goes offline in Dial Up operation 6 Select the Send DSTR checkbox to Send the DSTR string from iChip to the socket 7 Inthe Timeout Before Reestablishing Connection SNRD field type the value in seconds of the time interval for iChip to wait before attempting to reestablish a lost soc
64. stration 5 Inthe Ring Response Return Link RRRL field type the IP address of the ring response return link and the Web port 6 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 12 Configuring the User Fields Tab This procedure describes how to configure user fields which can be used for the following purposes General storage You can type any string in each of the fields in order to save a list Macro replacement What you need Access to the Configuration Tools window as described in 3 3 1 L3 How 1 Inthe Configuration Tools window click the User Fields tab The User Fields tab configuration fields are displayed Figure 25 Page 34 of 70 Connect One iChip Config Utility User Manual gt iChip Configuration tools File Search Parameter Remote FA ISP Connection Remote params update Email format Server profiles Operational am Serial NET IP registration j User fields RAS User Field 1 UF01 User Field 7 UF07 User Field 2 UF02 User Field 8 UF08 User Field 3 UF03 User Field 9 UF09 User Field 4 UF04 User Field 10 UF10 User Field 5 UF05 User Field 11 UF11 User Fi
65. t Gateway IP EIPG Assigned IP address IPA Use DHCP 0 i s 15 0 0 0 0 Use IP Finder Ethernet Subnet Mask ESNT e 40 10 60 Sub Net address SNET O sk 0 20 Gateway IP address 0 20 it aC iChip type C02144 D iChip plus LAN platform Firmware ver D809b15 5 4 2012 Serial num 14001040 Boot block 0801 9 6 2009 Close Port COM12 Baud Rate 115200 Figure 12 Full Configuration Window 2 The Configuration Tools window displays the tabs that enable you to configure various aspects of iChip functionality 3 Click the tab you want to configure 3 3 2 Configuring the Email Format Tab This procedure describes how to configure parameters for email format properties and sending and receiving emails Page 16 of 70 Connect One iChip Config Utility User Manual What you need Access to Configuration Tools window as described in Section 3 3 1 C7 How 1 In the Configuration Tools window click the Email Format tab The Email Format tab configuration fields are displayed Figure 13 iChip Configuration tools File Search Parameter Remote FA ISP Connection Remote params update Se Alternative addressee CC1 Message body BDY V Transmit Email headers XFH Limit number of headers HDL Alternative addressee CC2 0 Filter String FLS Alternative addressee CC3 Subject SBJ Alternative addressee CC4 Email address TOA 50 Addressee Media type MT Applicati
66. t iChip from issuing an ATZ command to the modem before dialing the ISP when an Internet session is activated ATZ is a standard modem AT command which resets the modem status Suppressing ATZ might be useful if you need to manually initialize your modem 6 In the Wait Time Constant WTC field type a value in seconds that the iChip waits for an answer as defined in the modem S7 register Sets iChip to support a specific modem type Analog modems SiLabs Si2400 ISOmodem GSM GPRS CDMA TDMA CDPD iDEN and AMPS wireless modems are supported Page 21 of 70 Connect One iChip Config Utility User Manual 7 10 11 12 13 14 15 16 17 18 19 20 In the TCP Timeout TTO field type a value in seconds that defines the time iChip waits for an Internet transaction to complete before returning a timeout error In the Inactivity Timeout IATO filed type a value in seconds that defines how long iChip waits from the last activity before ending the session SerialNET for iChip LAN disconnecting the line for iChip Dial Up For CDPD modems only In the CDPD Password CPWD field type the password for access to the modem From the Max Packet Size MPS dropdown list select the limit for outgoing PPP packets in a dialup environment The MPS upper limit is the iChip maximum transmission unit MTU From the Host Interface HIF dropdown list select the Interface over which the Host proces
67. the email account to which replies should be sent For receiving email a Inthe POP3 Server field type the name string or IP address of the POPS server you use to receive emails b In the Mailbox field type the email address at which you want to receive emails c In the Mailbox Password field type the password for the email address if one is required 4 Click Save A dialog box appears indicating the parameters are saved Figure 11 iChipConfig Parameters were saved successfully Figure 11 Parameters Saved Successfully Dialog Box 5 Click OK The Quick Configuration window closes and the iChip Configuration Tools window appears Page 15 of 70 Connect One iChip Config Utility User Manual 3 3 Full Configuration Tool 3 3 1 Accessing the Full Configuration Tool This procedure describes how to access configuration tabs for all the possible iChip parameters using the Full Configuration tool al What you need m Device or module using Connect One iChip or Connect One II EVB board connected to your workstation with power on C7 How 1 Inthe iChip Configuration Tools window click the Full Configuration icon The Configuration Tools window appears Figure 12 iChip Configuration tools File Search Parameter Wireless LAN Remote Few Additional LTYP 4 parameters MAC address MACA Default IP address DIP Ethernet Default IP address EDIP FFO000000000 D 0 0 0 S Etherne
68. the password is set to iChip allows Web updating without password authentication If the password is defined to any other value the user must submit that exact value to perform Web updates Page 30 of 70 Connect One iChip Config Utility User Manual 4 Do one of the following To apply the defined parameters and continue working in the Configuration Tools window click Apply To save the defined parameters and exit the Configuration Tools window click Save Your definitions are saved the Configuration Tools window closes and the iChip Configuration Tools window appears 3 3 10 Configuring the SerialNET Tab This procedure describes how to configure parameters for iChip to work in SerialNET mode abg z What you need Access to the Configuration Tools window as described in 3 3 1 C7 How 1 In the Configuration Tools window click the SerialNET tab The SerialNET tab configuration fields are displayed Figure 23 gt iChip Configuration tools File Search Parameter Remote Few ISP Connection Remote params update Ler FT Email format Server profiles Operational EE Characters to enforce flush FCHR Socket type STYP Serial Wakeup Timeout SWT TCP 600 Max characters before flush MCBF Server serialNET port LPRT HSS a nt ng p l eT Max timeout to flush MTTF IP address to connect to HSRV SerialNET Indicator Signal SLED Disconnection string DSTR Alt IP addre
69. this button to install iChipConfig software to the specified destination directory irectory CA Program FilestiChipConfigi Change Directory Exit Setup Figure 3 IChipConfig Setup Window with Installation Directory gt To change the installation directory a Click Change Directory The Change Directory window appears Change Directory Enter or select destination directory Path Ca Program FilestikhipConfiqgi Directories ac SProgram Files wa iChipContig Drives jc Figure 4 Change Directory Window b In the Path field type the destination directory in which to install the iChipConfig utility OR In the Directories area navigate to the destination directory c Click OK The Change Directory window closes and the iChipConfig Setup window refreshes displaying the new installation directory d Click the Install P icon The iChipConfig Choose Program Group window appears Page 9 of 70 Connect One iChip Config Utility User Manual iChipConfig Choose Program Group Setup will add items to the group shown in the Program Group box You can enter new group name or select one From the Existing Groups list Program Group Kannectkone Existing Groups ane Figure 5 iChipConfig Choose Program Group Window e Click Continue The iChipConfig Setup window appears displaying an installation progress bar iChipConfig Setup Destinat
70. tools File Search Parameter Cipher suite CS Private key PKEY 0 Propose All v Trusted Certificate Authority CA Load Certificate Clear Certificate Trusted Certificate Authority 2 CA2 Load Private Key Clear Private Key iChip Certificate Load Certificate Clear Certificate Trusted Certificate Authority 3 CA3 Load Certificate Clear Certificate Load Certificate Clear Certificate Trusted Certificate Authority 4 CA4 Load Certificate Clear Certificate iChip type CO2144 D iChip plus LAN platform Firmware ver D809b155 4 2012 Serial num 14001040 Boot block 0801 9 6 2009 MG Ready Port COM12 Baud Rate 115200 Figure 26 SSL Tab of Full Configuration Tool From the Cipher Suite CS dropdown list select the cipher suite to be used in SSL3 TLS1 negotiations with a secure server In the Trusted Certificate Authority CA fields 1 4 you can load up to 4 different certificates obtained from trusted certificate authorities iChip establishes an SSL3 TLS1 socket connection only to servers having a certificate authenticated by these authorities Use the Load Certificate button to load a certificate and the Clear Certificate button to remove it from the field Page 39 of 70 Connect One iChip Config Utility User Manual 4 Inthe Private Key PKEY field you can load iChip s private key The private key is required to perform an RSA encryption of its certificate
71. ty User Manual Working with iChipConfig IChipConfig Tools Overview Quick Configuration Full Configuration Tool Working with the iChip Uploader via Serial Tool Working with the Site Packer Tool Working with the iChip Uploader via HTTP Tool Working with the Dumb Terminal iChipConfig Tools Overview iChipConfig utility provides you with several tools that enable you to configure various parameters on your iChip Depending on the iChip model you are connected to and the iChip firmware version you use only the relevant parameters and sections are available Others are grayed out and cannot be configured Quick Configuration Quick Configuration Tool Overview The Quick Configuration tool enables you to configure only the essential AT i parameters required to send and retrieve an email This is a good way to make sure that the iChip is operational on the LAN side or that it is configured correctly to work with your ISP Quick Configuration parameters like all AT i parameters are stored in memory either internal or external and therefore need to be defined only once Working with the Quick Configuration Tool This procedure describes how to use the Quick Configuration tool to configure only those AT i parameters required to send and retrieve email I Additional mail configuration and manipulation parameters are available using the Full Configuration tool as described in Section 3 3 How 1 Inthe iChip Configur
72. u want to configure E E An RS232 cable E Windows XP operating system Quick Tour of the iChip Config Utility iChipConfig Utility Menus The iChipConfig utility uses the following menus Figure 1 File Tools Wizards Host lt gt iChip options Serial Ports SerialNET Options Help Figure 1 iChipConfig Utility Main Menu Bar m File Enables you to load an RPF file a file including configuration parameters or exit the program Tools The Tools menu lists the same options as the icons displayed in the iChip Configuration Tools Main window and more m Wizards Provides access to the Communication Platform Wizard and the SerialNET Configuration Wizard Host lt gt iChip Options Enables you to configure the connection mode between the host and iChip either via COM port or socket Page 6 of 70 1 3 2 Connect One iChip Config Utility User Manual Serial Ports Opens the Serial Settings window where you can change the COM port on the PC and the PC s COM port baud rate SerialNET Enables you to enter and exit Serial NET mode iChip Config Utility Functionality iChipConfig utility provides you with the following tools m Quick Configuration m Full Configuration m Firmware Update m Web Parameters Update iChip Uploader via Serial m iChip Website Uploader via HTTP E Dumb Terminal m Send email attachment m Receive emails m Get URL m Change iChip communication platform I Every iChip has its own s
73. unication Platform Wizard What you need Completion of Starting the Communication Platform Wizard with the Dialup parameter selected How 1 After you click Next in the first Communication Platform Wizard window the ISP Account Parameters area for dialup GSM appears Figure 39 Communication Platform Wizard Enter ISP Account parameters Phone number 3 1 234567 User name Jusemame Password password Back Next Cancel Figure 39 Communication Platform Wizard ISP Account Parameters In the Phone Number field type the number you use to connect to your ISP In the Username field type the username you use to access your ISP account In the Password field type the password you use to access your ISP account Click Next The Finish View Settings area appears Figure 42 6 Continue with Viewing and Completing Communication Platform Configuration iChipConfig Utility will also send the iChip additional parameters that set the authentication method and appropriate values for modem type and modem initialization string for dialup analog or GSM modem Page 54 of 70 Connect One iChip Config Utility User Manual Configuring GPRS Parameters This procedure describes how to configure GPRS communication platform parameters using the Communication Platform Wizard What you need Completion of Starting the Communication Platform Wizard with the GPRS parameter selected L3 How
74. uration TOOl rrrrnrnnnnnronrnnnnnnvnnnrnnnnnvnnrnnnnsennnnnnnnsennnnnnnnsrnnnnnnsnsrnnnnnnssennnnnnsee 16 3 3 1 Accessing the Full Configuration TOO rrrnnnnrrrnnnnnnnrvnrrnnnnnrennrnnnnnrennnnnensennnnnnsneenn 16 3 3 2 Configuring the Email Format Tab rrrnnnernnnrnnnnnnnnnvrnnrrnnnnnnnnrrnnnnnnnnnnnsrnnnrnnnnnsnnnee 16 3 3 3 Configuring the Server Profiles Tab rrrrrnnrrrnnnnnnnnvvnnrrrnnnnnnnnvvnnnrrnnnnnsrnnnnrnnnnnsnnnee 19 3 3 4 Configuring the Operational Parameters Tab rrrrrrnrrrnnnnnnnnvvnnnrrnnnnnnnnrvnnnnnnnnnnnee 20 3 3 5 Configuring the LAN Tab srrrnnernnrrnnnnnnnnnrnnnrrnnnnnnnnsrrnnnnnnnnnnsrnnnrrnnnnnnnssrnnnnnnnnnsnnnee 25 3 3 6 Configuring the Remote FW Tab rrrnnrrnnennnnrnnnnnnnnornnvrrnnnnnnnnsennrnnnnnnnnssnnnrnnnnnnnnnee 26 3 3 7 Configuring the ISP Connection Tab rrrrrnnnrrnnnnnnnnvvrnvrrnnnnnnnnvrnnnrrnnnnnssennnrrnnnnnnnnee 27 3 3 8 Configuring the Remote Params Update Tab rrrrrrnnnnnrnnrnnnnnnrnrrnnnnnrnnnnnnnnnrrnnnnnnne 29 3 3 9 Configuring the HTTP Tab rrrnnnnnrrnnnnnnnnnvnnnrrnnnnnnnnsrrnnnnnnnnnnsrnnnrnnnnnnnnssennnnnnnnnnnnsee 30 3 3 10 Configuring the SerialNET Tab rrrrnnnnnnnnnnnnrrnnnnnnnnvrrnnrrnnnnnnnrnnnrrnnnnnnnssennnrnnnnnsnnnee 31 3 3 11 Configuring the IP Registration Tab rrrrrnnrrnnnnnnnnvvrnvrrnnnnnnnnvrnnnrnnnnnnnsrnnnrnnnnnnnnnee 33 3 3 12 Configuring the User Fields Tab rrrnnnnnnnnnnnrnnnnnnnnnvrnvrrnnnnnnnnnnnrrnnnnnnnnsennn
75. ware Using the iChip Uploader Note This procedure assumes that the SPI flash memory on the EVB 630W already contains a previous version of the iChip firmware 1 Open the iChipConfig utility Page 44 of 70 Connect One iChip Config Utility User Manual 1Chip Configuration tools Seles File Tools Wizards Host lt gt iChip options Serial Ports SerialNET Options Help Connect Ine Click on the desired operation icon Quick Configuration Site Pack Send Email Script Tool attachment IChip site Uploader Receive Email Change iChip via HTTP plus platform yaaa W ae iChip Uploader Dumb Terminal la serial 1101 0010 0111 0010 Part COM12 Baud Fate 115200 2 Click the iChip Uploader via Serial icon 3 In the dialog box displayed select the EBI Flash 16 Megabit for 2Mbyte Flash option and click OK Choose Flash Type Flash Types f SPI Flash 4 Megabit f EBI Flash 8 Megabit 512 K x16 bit bottar co EBI Flash 64 Megabit 4 M 16 bit OF Cancel 4 The Monitor Mode dialog box is displayed Click the FW Update bution Page 45 of 70 Connect One iChip Config Utility User Manual gt Monitror Mode Connect ne gt General Settings Baud rate 115200 Scan Operations Fw Update Memory Dump Dump Memory to file Exit Monitor mode 5 In the dialog box that appears browse to the location of the firmware IMF file you obtained from Connect One s
76. wer Communication Platform Dialup ISP Phone Number 12345677 ISP User Name nane ISF Password password Figure 43 General Viewer Window Page 57 of 70 Connect One iChip Config Utility User Manual 3 To save the settings and exit the wizard click Finish The settings are saved and the Communication Platform Wizard closes 4 3 SerialNET Configuration Wizard The SerialNET Configuration Wizard enables you to establish connection between your device and a remote server without doing extensive research or needing to understand every SerialNET parameter Once the connection is enabled fine tuning of the SerialNET setting is required for best performance 4 3 1 Starting the SerialNET Configuration Wizard This procedure describes how to access the SerialNET Configuration Wizard and begin defining SerialINET parameters Fj How E From the iChipConfig main menu bar select Wizards gt SerialNET Wizard The SerialNET Configuration Wizard window appears Figure 44 gt SerailNET Getting started Wizard Does your device initiate first connection f Yes C Ho Cancel Figure 45 SerialNET Getting Started Wizard 4 3 2 Configuring Connection Initiation This procedure describes how to configure connection initiation parameters which are different depending on whether your device initiates the connection or is polled from the remote location to create a connection These setting apply ONLY to the FIRST co