XA 16mm

image

Contents

1. Tel 1 408 747 0550 800 262 IDEC 4332 Tel 49 40 25 30 54 10 Fax 49 40 25 30 54 24 Westlands Road Fax 1 408 744 9055 800 635 6246 E mail service idec de Quarry Bay Hong Kong E mail opencontact idec com IDEC AUSTRALIA PTY LTD Tel 852 2803 8989 Fax 852 2565 0171 IDEC CANADA LIMITED 2 3 Macro Court Rowville Victoria 3178 Australia Ea ioaea coi Unit 22 151 Brunel Road Mississauga Ontario Tel 61 3 9763 3244 Toll Free 1800 68 4332 IDEC SHANGHAI CORPORATION L4Z 1X3 Canada Fax 61 3 9763 3255 E mail sales au idec com Room 608 609 6F Gangtai Plaza No 700 Tel 1 905 890 8561 Toll Free 888 317 4332 Yan an East Road Shanghai 200030 China Fax 1 905 890 8562 ae IZUMI ASIA PTE LTD Tel 86 21 5353 1000 Fax 86 21 5353 1263 i l o 31 Tannery Lane 05 01 Dragon Land Building Hp E mail sales ca idec com Singapore 347788 E mail idec cn idec com IDEC ELECTRONICS LIMITED Tel 65 6746 1155 Fax 65 6844 5995 IDEC TAIWAN CORPORATION Unit 2 Beechwood Chineham Business Park E mail info sg idec com 8F No 79 Hsin Tai Wu Road Sec 1 Hsi Chih Basingstoke Hampshire RG24 8WA UK Taipei County Taiwan WWW idec com Tel 44 1256 321000 Fax 44 1256 327755 Tel 886 2 2698 3929 Fax 886 2 2698 3931 E mail sales uk idec com E mail service idectwn com tw Cat No EP1093 0 FEBRUARY 2006 14DNP PRINTED IN JAPAN
2. Push to lock 10 5N NC main contacts NO monitor contact Operating Force Pull to reset 10N s Turn to reset 0 16 N m Rated Insulation Voltage Ui 300V illuminated part 60V Ith e 125V 250V Opening Action Minimum Operator 4 0 mm 4 5mm Resistive Load 50 60 Hz inductive Load Direct Opening Action re Stroke g Contacts Resistive Load e DC 12 2A 0 4A 0 2A 50 mQ maximum initial value DC 7 a E 0C 13 22A 0 Overwotage Category fh D Resistive Load Impulse Withstand E 50 60 HZ Inductive Load Pollution Degree 3 inside LED unit 2 T a AC 14 0 6A 0 3A oc oe Operation Frequency 900 operations hour 2A 0 4A 0 2A Operating extremes 150 m s DG DG12 AOT RERNE Damage limits 1000 m s Inductive Load 0 22A Operating extremes 10 to 500 Hz amplitude 0 35 DC 13 a mm acceleration 50 m s as Vibration Resistance eee e Minimum applicable load 5V AC DC 1 mA reference value Damage limits 10 to 500 Hz amplitude 0 35 Operating area may vary according to the operating conditions and load mm acceleration 50 m s types Mechanical Life 250 000 operations minimum Approval Organization File No Degree of Protection IP65 IEC60529 Standard Short circuit Protection 290V 10A fuse Type aM IEC60269 1 IEC60269 2 imum UL508 CSA G22 2 No 14 The rated operating currents are measured at resistive inductive load types Electrical Life 100 000 operations minimum specified in IEC 60947 5 1 250 000 operations m
3. Think Automation and beyond VIDEC 016mm XA series Emergency Stop Switches Illuminated Type IDEC CORPORATION 16mm XA series Illuminated Emergency Stop Switches The World s First 616 mm 4 contact Emergency Stop Switch Compact size only 27 9 mm deep behind the panel e 1 to 4NC main contacts and 1NO monitor contact e The depth behind the panel is only 27 9 mm for 1 to 4 contacts e IDEC s original Safe break action ensures that the con tacts open when the contact block is detached from the operator e Push to lock Pull or Turn to reset operator e Two operator sizes 329 and 940 mm e Safety lock mechanism IEC60947 5 5 6 2 e Degree of protection IP65 IEC60529 e Direct opening action mechanism IEC60947 5 5 5 2 IEC60947 5 1 Annex K e UL c UL recognized EN compliant e ROHS compliant EU directive 2002 95 EC Contains no lead cadmium mercury hexavalent chromium PBB or PBDE Specifications IEC60947 5 1 EN60947 5 1 Applicable Standards IEC60947 5 5 Note EN60947 5 5 Note JIS C8201 5 1 UL508 CSA C22 2 No 14 Operating Temperature 25 to 55 C no freezing Illumination Ratings Rated Voltage Operating Voltage Rated Current 24V AC DC 24V AC DC 10 Note Except for stop switches operator color gray Operating Humidity 45 to 85 RH no condensation i Contact Ratings Minimum Force Rated Operating Voltage Ue Required for Direct f
4. e LED unit while squeezing the latches on the LED unit using Align the to of the LED unit with the TOP marking on the the LED unit removal tool MT 101 contact block Push the LED unit into the contact block Squeeze the LED unit on the latches and pull out TOP side Latches TOP side N Safety Precautions e Turn off power to the XA series emergency stop switch before e Use wires of the proper size to meet the voltage and current starting installation removal wiring maintenance and inspec requirements and solder the wires correctly If soldering is tion of the relays Failure to turn power off may cause electrical incomplete the wire may heat during operation causing fire shock or fire hazard hazard e Use the LED unit removal tool when replacing the LED unit to e Read the user s manual to ensure correct operation before start avoid burn on your hands ing installation wiring operation maintenance and inspection of the XA emergency stop switches Specifications and other descriptions in this catalog are subject to change without notice 7 31 Nishi Miyahara 1 Chome Yodogawa ku Osaka 532 8550 Japan IDEC CORPORATION Tel 81 6 6398 2571 Fax 81 6 6392 9731 E mail products idec co jp iL D i C IDEC CORPORATION USA IDEC ELEKTROTECHNIK GmbH IDEC IZUMI H K CO LTD 1175 Elko Drive Sunnyvale CA 94089 2209 USA Wendenstrasse 331 D 20537 Hamburg Germany Unit 1505 07 DCH Commercial Centre No 25
5. ection diode Terminal Arrangement Bottom View Illuminated Type e NC main contacts only e With NO monitor contacts NC main contacts Terminals 1 2 NC main contacts Terminals 1 2 Mou nting Hole Layout NO monitor contacts Terminals 3 4 TOP 0 2 16 2 0 i 29mm Operator 40 mm minimum 5 r ar Left s 40mm Operator 50 mm minimum Y e The values shown above are the minimum cael sain dimensions for mounting with other 16 mm pushbuttons For other control units of different sizes and styles determine the 1NC Terminals on right 1NC Terminals on top values according to the dimensions opera 2NC Terminals on right and left 2NC Terminals on right and left pe X tion and wiring convenience 3NC Terminals on right left and top WipEc 216mm XA series Illuminated Emergency Stop Switches Nameplates Type No Material Plate Color Legend Color HAAV For 29mm Operator EMERGENCY STOP E Polyamide Yellow Black For 40mm Operator EMERGENCY STOP H 21 Accessories and Replacement Parts CE iaa T Package Terminal Cover XA9Z VL2 XA9Z VL2PN02 E e Used for solder terminals LED Unit l 5N For Solder Terminal Solder Terminal XA9Z LED2R XA9Z LED2R ip ay e Replacement LED unit For PC Board Terminal XA9Z LED2VR XA9Z LED2VR Stainless Steel MT 101 MT 101 e Used for removing the LED unit Removing the LED Unit Installing the LED Unit Pull out th
6. inimum 24V AC DC 100 mA UL c UL File No E68961 Conditional Short circuit Current 1000A Terminal Style Solder terminal PC Board terminal i Recommended Tightening Torque 0 88 N m for Locking Ring TUV Product Service EN60947 5 1 EN60947 5 5 Note Connectable Wire 1 25 mm maximum AWG16 maximum Soldering Conditions 310 to 350 C 3 seconds maximum Weight 29 mm type 23g 40 mm type 28g CCC Note Except for stop switches operator color gray AAE No 2005010305150899 European Commission s Low Voltage Directive FIDEC 216mm XA series Illuminated Emergency Stop Switches Types Illuminated Solder Terminal PC Board Terminal Types Appearance cue eee ies Contact Contact Color 29mm Operator pane d SSCA LSI MENOR Oac CXATELVa0204R XATE LVS0204VR O ae Xmen XMEIV3OOAVR O ace XER XAYE LVS0AOAVR Dark red only a40mm Operator Oom o O XNE XATE LVA01GAVR enc Xmen XAYE LVA0204VR O ace Xmen XAEAVAOOAVR Ooae XER XATE LVA0404VR e Terminal cover XA9Z VL2 is ordered separately Dimensions Panel Cut out e Illuminated Type Mounting Panel Thickness 0 5 to 3 7 0 2 1 70 T o Bo 92 JU 0000 All dimensions in mm Terminal Cover XA9Z VL2 240mm Operator PC Board Terminal Type Solder Terminal Type PC Board Layout Bottom View 19 8 Vv l K LED chip tq Prot