Home

873 user`s manual

image

Contents

1. 3 Application of IO control have 2 on off input ports 2 on off output ports you can use as follow User terminal on off output app circuit on off Output Mini Power Wireless Module User s Manual on off Input User terminal on off output Input app circuit 3 Saving power model have three Saving power models awaken from Hardware awaken from COM Port awaken from Air The model can be set by RF Module software You can choose one saving power model the default model is awaken from Hardware 1 Awaken from Hardware When sleeping in this saving power model the current is under 100uA Sleeping status when you input low level at NO 5 pin can sleep In this status cannot transmit and receive data Normal work status when you input High level at NO 5 pin turn into Normal work status 10ms later can transmit and receive data Remarks if you keep the NO 5 pin untouched then in Normal work status 2 Awaken from COM Port When sleeping in this saving power model the current is under 11mA When you input data to with COM port turn into Normal work status after 10mS and can transmit the data When did not receive data in COM port in the period of 20 seconds will turn into sleep status 3 Awaken from Air When sleeping in this saving power model the current is under 20mA When in this saving power status works intermittently When received awaken data from air will turn into normal work status af
2. can attemper the appurtenant station IO according to communication protocol of Remark when you use IO attemper function we provide communication protocol of and programme manual parameters setting have one interface of TTL RS232 RS485 You must specify the interface when you buy main parameters COM baud rate and verify RF baud rate Channel and frequency You can change these parameters by our RF Module soft When RF baud rate is faster than COM baud rate One frame Can transmit limitless data When RF baud rate is not faster than COM baud rate One frame Can transmit 255 bytes most You can set the rate according your need The general Power supply is 5V DC Two communicate must have condition as follow 1 Their channels i e frequency are the same 2 Their RF rates are the same 3 RF Module Com baud rate and verify is agree with its equipment or PC that it connects with Parameters default value Channel 1 Interface speed rate 9600BPS Interface verify none Speed rate in air 9600BPS Channel and frequency list 868MHZ 16 channel Technical specification of Modulation mode GFSK Working frequency 866MHZ Transmission power lt 500mW Receiving sensitivity 123dBm Transmitting current lt 360mA Receiving current lt 45mA Sleeping current lt IlmA Channel speed rate 1200 2400 4800 9600 19200 38400Bit s User can Choose one Mini Power Wireless Module User s Manual Interface speed rate 1200
3. for it before place an order 4 IO attemper function have 2 on off input ports 2 on off output ports 5 ISM frequency band not requiring on application of frequency point Carrier frequency of 433MHz also capable of 868 915MHz 6 High anti interference and low BER Bit error Rate Based on the GFSK modulation mode it adopts the efficient communication protocol The actual bit error rate of 10 5 10 6 can be achieved when channel bit error rate is 10 2 7 Long transmission distance Within the range of visibility the reliable transmission distance is BER 10 3 1200bps gt 3000m when the antenna height is greater than 2000m BER 10 3 9600bps 8 Transparent data transmission Transparent data interface is offered to suit any standard or nonstandard user protocol Any false data generated in the air can be filtrated automatically What has been received is exactly what has been transmitted The charge time for receiving and sending lt 10ms 9 Multi channel and speed The standard configuration provides 16 channels to meet the multiple communication combination mode of the users It has baud rate to be chosen such as 1200bps 2400bps 4800bps 9600bps 19200bps 38400bps The wireless transmission rate is direct ratio with baud rate of interface to meet user s equipment requirement 10 High speed wireless communication and large data buffer When the speed rate in the air is quicker than interface s allowing to transmit unlimited
4. length data at one time when the speed rate is slower or equal the interface s allowing the transmission of 255 Bytes long data frames at one time for more flexible programming by users 11 Intelligent data control and the user doesn t need to prepare excessive programs Even for semi duplex communication the user doesn t need to prepare excessive programs only receiving transmitting the data from the interface will automatically complete the other operations such as transmission receiving conversion in the air control etc 12 High reliability small and light Single chip radio frequency integrated circuit and single chip MCU are used for lessened peripheral circuits high reliability and low failure rate 13 Watchdog monitor Watchdog monitors the inner function so that change the traditional product structure and improve the product reliability Mini Power Wireless Module User s Manual Application of 1 Appearance figure TX RX indicator light Antenna socket x Red TX Green RX User interface 2 interface definition 1 User s interface have one interface of TTL RS232 RS485 user can choose one standard interface when the antenna upward the plastic socket gap upward from left to right 1 9 pin in turn as below figure Remarks Jack space between is 2 0 mm Definition of connecting pins and connection method Itemno PIN Description Level Connected User terminal Remarks to the termi
5. 2400 4800 9600 19200 38400Bit s User can Choose one Change time for receiving and sending lt 10ms Interface data format 8E1 8N1 801 Power supply 5 0 5V DC Working temperature 20 C 85 C Working humidity 10 90 relative humidity without condensation Dimension 58mm 38mm 10 mm Model and name T TTL interface 2 232 interface 4 485 interface Naked board Optional Antenna Er spillikin Flagelliform Small acetabula antenna Trouble and solve ways NO Trouble Trouble causes and solve ways a Power Line badness touch No shine of j 1 b Power is bad Indicator light l c Powerline meetin reverse or diode of polarity protect is bad a Radio is badness touch with PC terminal No transmit or 2 b Radio with TTL RS232 RS485 not match terminal No receive c RX frequency and TX frequency is not same Mini Power Wireless Module User s Manual a antenna not match or touch bad Bit error rate 2 i b RF baud rate is not right High ae c Power supply ripple is too great Indicator light a Electromagnetism disturb in circumstance twinkling b Same frequency disturb in the circumstance
6. Low Power Wireless Module User s Manual Fe 5 y je e v Before using the product please read the user s manual carefully Any question in technical you can contact us About the Low power wireless module is used as the wireless data transmission in short distance With the small size weight and power consumption and good stability and reliability it has the function of bi directional data sign transmission test and control It is used for Wireless meter reading such as water meter electric meter and gas meter parking meter intellective card electronic weighing apparatus meter for checking on work attendance queue wireless meter building control shipping company control alarm system intelligent equipment Automatic data collecting system Industrial remote control and remote test building automation safety and security powerhouse equipment wireless monitor entrance control system etc It provide the USB power interface to be convenient for the mini computer and PC users if necessary Mini Power Wireless Module User s Manual Feature 1 Ultra low power transmission Transmission power 500mW high receiving sensitivity 123dbm size 58mm 38mm 10 mm 2 Low power consumption Receiving current lt 45mA transmission current lt 360mA sleeping current lt 1mA 3 Saving power model have three saving power models awaken from Hardware awaken from COM Port awaken from air the user need to ask
7. nal 1 SLE Sleep control input end Low level to sleep High level awake 2 TXD A RS 485 Serial data transmitting end RXD A RS 485 3 RXD B RS 485 Serial data receiving end TXD B RS 485 4 GND Power supply Ground DGND AGND 5 VCC 5 0 5V 5 0 5V TTL 3V user s choose Mini Power Wireless Module User s Manual 6 b NO 2 on off input user terminal on off output 7 I NO 1 on off input user terminal on off output 8 Or NO 2 on off output user terminal on off input 9 O1 NO 1 on off output user terminal on off input User s equipment 5v regulator n power supply transmitter receiver Remarks To avoid to connect the interface reverse and can not communicate please check and assure the voltage of 2 and 3 pin is existing by using Multimeter If there is one pin that has the voltage another has not voltage which means the interface is connected reverse please change the connection wires between pin 2 and 3 2 Power supply uses DC power supply with voltage of 5V It can also share power supply with other equipment however the high quality power supply with desirable ripple factor should be selected In addition the reliable grounding must be used if there is other device in the system equipment In case of failure to connect with the earth it can form its own grounding but it must be absolutely separated from the municipal electric supply
8. ter 10ms it can receive data normally When did not receive data from air in the period of 20 seconds it will turn into sleep So when you wake up from air you can transmit some useless data firstly 4 IO Attemper Function have two communicate protocol full transparence protocol and ID protocol Remark full transparence protocol is default protocol if you need with ID protocol please tell us when you book 1 Full transparence protocol In this mode whatever you use any data frame can send it to another side as like as two peas it cannot change data format and data bits with this transmit mode be used for Reading meter RTU and PLC with Address itself and so on 2 ID protocol When your terminal without Address or ID you can use with ID protocol in this way you can differentiate the data from you terminal The Main station you must use with full transparence protocol the appurtenant station you must use with ID protocol The of the appurtenant station must set ID according Mini Power Wireless Module User s Manual our RF module software you can resolve the data from user terminal transmit according to ID Protocol Remark when you use with ID protocol we provide communication protocol of and programme manual 3 IO attemper function You can use one with full transparence protocol for the Main station some with ID protocol for the appurtenant stations each of the appurtenant station must set one unrepeatable ID You