Home
Installation - Transition Networks
Contents
1. Manufacturer s rated ambient temperature for the dual slot chassis Refer to the user s guide of the installed media converter for its operating temperature range techsupport transition com Click the Transition Now link for a live Web chat 5 CPSMC0200 22x Troubleshooting 1 Is a media converter installed in the dual slot chassis NO e Install a slide in module media converter into the dual slot chassis See page 2 for installation instructions e Proceed to step 2 YES e Proceed to step 2 Is the Power LED on the installed media converter illuminated NO e Is the power supply the proper type of voltage and cycle frequency for the AC outlet See Power Supply DC Output on page 5 e Is the power supply properly installed in the chassis and in the grounded AC outlet e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES e Proceed to step 3 Are two gigabit media converters installed in the dual slot chassis YES e The CPSMC0200 22x dual slot chassis can accommodate only one gigabit media converter Remove one of the two gigabit media converters e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 NO e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 Contact Us Technical Support Technical support is available 24 hours a day United States 800 260 1312 I
2. this example the second slot must remain unused Compliance EN55022 Class A amp B CE Mark Dimensions 5 7 x 5 5 x 2 2 in 145 x 139 7 x 56 mm Weight 1 8 lb 0 817kg approximately MTBF 48 501 hours MIL217F2 V5 0 MIL HDBK 217F 128 553 hours Bellcore7 V5 0 Maximum power delivery capacity CPSMC0200 22x 12 Watts Power Supplies Shipped 12VDC 1 25A 100 240VAC 50 60Hz Optional 12VDC 2 5A 100 240VAC 50 60Hz Environment Tmra 0 to 60 C 32 to 140 F Storage Temp 20 to 85 C Humidity 10 to 90 non condensing Altitude 0 to 10 000 feet Warranty Lifetime The information in this user s guide is subject to change For the most up to date information on the CPSMC0100 22x dual slot chassis view the user s guide on line at www transition com WARNING Visible and invisible laser radiation when open Do not stare into the beam or view the beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure MTBF is estimated using the predictability method This method is based on MIL 217F at 25 C ambient temperature typical enclosure heat rise of 10 C and nominal operating conditions and parameters Installation and configuration specific MTBF estimates are available upon request Contact Technical Support
3. aN One User s Guide CPSMC0200 22x Dual Slot PointSystem Chassis The Transition Networks CPSMC0200 22x series dual slot PointSystem chassis is designed for installation of two selectable Transition Networks PointSystem media converter slide in modules The redundant power option provides the means to power the chassis from two independent power supplies Part Number Description CPSMC0200 221 Dual Slot Point System chassis with two power supplies one grounded and one ungrounded The chassis provides Last Gasp trap generation CPSMC0200 226 Dual Slot Point System chassis with two power supplies one grounded and one ungrounded Optional Accessories sold separately Part Number Description SPS 1872 SA Optional External Power Supply 18 60VDC Stand Alone Output 12 6VDC 1 0A WMBP Optional Wall Mount Bracket Length 5 0in 127 mm WMBV Optional Vertical Mount Bracket 5 0 in 127 mm WMBD Optional DIN Rail Mount Bracket 5 0 in 127 mm Installation 00 2 Technical Specifications 4 Troubleshooting 5 Compliance Information 6 CONTACE US gasa oie wield ss iia ree 7 CPSMC0200 22x Installation Installing a slide in module CAUTION DO NOT install Two 2 Point System media converter slide in modules with a total power requirement exceeding 12 W with an average of 6 W per slot Failure to observe this caution could
4. ation for this activity can wages be found in the Contact Us portion of this document CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein offentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten tiber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformitat Trademark Notice All trademarks and registered trademarks are the property of their respective owners Copyright Restrictions 2001 2004 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks 8 Printed in the U S A 33362 B
5. e to installation specific Protective Ground fault conditions Note The power supply shipped with the chassis has its secondary connected to protective earth ground The optional power supply does not have its secondary connected to protective earth Do Not use two power supplies with grounded secondaries to power the chassis To supply power to the dual slot chassis using the power supply 1 Connect the barrel connector of the power supply grounded secondary to one of the dual slot chassis power ports located on the back of the chassis See figure below If using the grounded secondary power supply only go to step 3 2 Connect the barrel connector of the second power supply ungrounded secondary to the dual slot chassis remaining power port Connect the power supply plug s into AC power 4 Verify that the dual slot chassis is powered by observing the illuminated LED s on the chassis front panel See the figure below Note If the power supply supplies are 11 VDC or above the associated LED LEDs will be lit PS7 LED PS2 LED If either power supply s output is under the 11VDC minimum requirement that LED will not turn ON indicating a problem DC power source Chassis Back Panel Chassis Front Panel P S 1 6 LED mo O lt P S2 O LED P S 2 P S 1 IN IN To power the dual slot chassis using the SPS1872 SA DC external power supply consult the SPS1872 SA use
6. nformation CISPR EN55022 Class A amp B CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Class A amp B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference In which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A amp B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A amp B prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Transition Networks will accept post usage returns of this product for proper disposal The contact inform
7. nternational 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 TRANSITION Declaration of Conformity N NETWORKS Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model CPSMC0200 22x Serues Dual Slot PointSystem Chassis Part Numbers CPSMC0200 221 CPSMC0200 226 Regulation EMC Directive 89 336 EEC Purpose To declare that the CPSMC0200 2x0 to which this declaration refers is in conformity with the following standards EN 55022 1998 Class A amp B FCC Part 15 Subpart B I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Ia Sr OOO Sap ee july 18 2006 Stephen Anderson Vice President of Engineering Date 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat Compliance I
8. nut fasteners is specified by the connector s manufacturer To properly ground the dual slot chassis Lug Nut gt Star Washer gt fAasesssssfess 9 12 AWG Copper Wire Grounding Screw __y not included 6 32 x 1 8 kw 1 Obtain one 1 grounding conductor 12 AWG copper wire gauge or larger with a two hole compression type grounding connector 2 Attach the grounding conductor to the converter by placing the two hole connector onto the grounding lugs and fasten with the enclosed lock washers lug nuts at the proper torque per the manufacturer s specification grounding conductor to the common bonding network CBN for telecom or to earth ground if required for non telecom installations 3 Attach the opposite end ofthe f aP Grounding Lugs Connect to Earth Ground 4 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Technical Specifications For use with Transition Networks Model CPSMC0200 22x or equivalent Note The CPSMC0200 22x dual slot chassis is Class B compliant ONLY if Class B compliant media converters are installed Installation of a Class A compliant media converter reduces the chassis to Class A compliance The maximum power delivery capacity for each chassis slot is 12 Watts with an aggregate chassis maximum of 6 watts per slot Example A 12 Watt media converter would require the power of both slots In
9. r manual at Transition Networks com Last Gasp Option CPSMC0200 221 models only The CPSMC0200 221 models feature the Last Gasp option which enables the device to send an SNMP trap in the event of a power failure alerting the management console that the device has failed 2 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 3 CPSMC0200 22x Installation Continued Grounding the Media Converter The dual slot chassis comes equipped with grounding lugs located on the back panel They require a grounding conductor wire terminated with a two hole compression type grounding connector The grounding wire which must be a copper conductor is not included with the chassis and must be provided by the customer installer The electrical conducting path from the dual slot chassis must e Flow via the grounding lugs to the common bonding network CBN for telecom installations or to an alternative approved grounding system if required for non telecom installations e Be of sufficiently low impedance to conduct fault currents likely to be imposed on the media converter and e Enable proper operation of any over current protection devices The conductor must be fastened to the grounding lugs with the enclosed anti rotation star washers and lug nut fasteners The applied torque required to the connector lug
10. result in data losses and media converter failure CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing the media converter slide in module into the chassis Failure to observe this caution could result in damage or failure of the media converter Note If only installing one slide in module ensure network standards compliance by obtaining a custom faceplate P N CPSFP 200 from Transition Networks for installation into the second unused slot To install a slide in module into the dual slot chassis 1 Refer to the user s guide that comes with the slide in module to ensure that any switches or jumpers on the slide in module circuit board are set correctly for the site installation 2 Carefully align the slide in module with the chassis installation guides and slide the module into the installation slot 3 Ensure that the slide in module is firmly seated inside the chassis 4 Push in and rotate the attached panel faster screw clockwise to secure the slide in module to the chassis front 5 Repeat steps 1 4 for the second slide in module Panel Fastener Screw Installation Continued Power the chassis CAUTION When using two power supplies to power the chassis one must be a power supply with an ungrounded secondary Using two power supplies with each secondary grounded to protective earth ground could cause unreliable operation of the chassis and its converters du