Home
JXDH-6002-6B QPSK Demodulator User Manual V3.5
Contents
1. parameters state inquiry even cancel modify etc Note make sure press confirm button once you setup new parameters when it displays Saving Done means the parameters setup successful while the parameter displays symbol it means this parameter in effective otherwise means keep the original parameters or to re select parameters 2 2 Mode select Startup displays System Initializing Please be patient Then display main screen LNB1 UnLock F 04040MHz SR 27500k In the main screen press Up Down button you can see the correspondingly channel signal work situation down link frequency or symbol rate value you can see if the setting Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator for this channel is right or wrong lock or unlock It can help us to find the problem promptly and solve it If the top right screen displays Unlock means this channel signal unlocked you d better check each parameter and check if the cable connected right or wrong when top right displays Locked mean this channel working normal And the corresponding channel indictor light green 2 3 Parameters modification and setting up Menu Framework Setup IP address Setup IP address 101 101 101 010 Setup submask Setup submask 255 255 255 000 Receiver1 UnLock Setup physical F 04040MHz SR 27500k addre
2. signal then IQ signal be sent to date demodulator chip afterwards standard synchronous parallel data output 1 4 2 2 Data processor FGPA After FPGA got corresponding parallel data it output standard MPEG 2 stream ASI interface digital signal for the use of devices such as scrambler modulator and so on Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 1 5 Panels and Instructions 1 5 1 Front panel JXDH 6002 6 QPSK Demodulator Digital Power O Lock1O Lock4O A Enter Meni Video Alarm O Lock3O Lock6O V Cheng Du Jiexun Electronics Co LTD ARSE HT BR ZS 1 2 3 4 5 6 7 1 LCD display 2 Power indicator 3 Alarm lock indicator 4 Lock indicator 5 UP DOWN LEFT RIGHT Button 6 Confirm Unlock button 7 Menu button 1 5 2 Back Panel AC110V 220V 50 60Hz Ethernet r O EE From left to right followed by 1 Network interface RJ45 2 LNB input 1 LNB loop output 1 3 LNB input 2 LNB loop output 2 4 LNB input 3 LNB loop output 3 5 LNB input 4 LNB loop output 4 6 LNB input 4 LNB loop output 5 7 ASI bit stream input 8 MUX multiplexed bit stream ouput 1 2 9 Power switch ON for turn on OFF for turn off 10 Fuse pipe 2A AC250V 11 Power socket connect to AC180 AC240V 20 60MHz 12 Ground pole for complete appliance Chengdu Jiexun Electronics Co Ltd Telephone 028
3. 4al ehan JXDH 6002 6B QPSK Demodulator User Manual V3 5 Chengdu Jiexun Electronics Co Ltd JXDH 6002 6B QPSK Demodulator Charter 1 Product Outline 1 1 Outline JXDH 6002 6B QPSK TS Demodulator used for receiving and transferring 5 routes DVB S channels to 5 routes TS stream signal directly then convert via FPGA outputting ASI to devices such as Multiplexer or Modulator No need to do process of decompression encoding etc The other ASI input route can receive EPG or other TS stream and it has inner multiplexer It is widely used in satellite digital TV data broadcasting Internet etc 1 2 Features e Support 5 routes LNB independent input or loop input 1 route ASI TS stream input by inner multiplexer it output one ASI TS and one backup of ASI TS stream output Support EPG or other ASI TS inputs multiplex by inner multiplexer LNB input frequency range 950 2150 MHz Interface comply with ASI standard DVB MPEG 2 both compatible SCPC MCPC compatible can receive all domestic and foreign non encrypted digital programs Polarization mode Horizontal vertical for optional F head for optional C Ku band compatible Adopt ultra low threshold integrated tuner high reliability good performance power off memory Stable and reliable performance strong anti interference capability Application e Digital satellite television broadcasting e MMDS digital TV front end e Digital cable television netwo
4. 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator LNB input port receive the signal which receive from the satellite antenna via F head e NB loop output port it can put the same satellite signal sources supply to other LNB input port or to other input device Charter 2 Installation Guide 1 1 Inspection upon reception Open the device packing carton make sure to check all the packages for the small parts check the commodities according to the packing list or below items e JXDH 6002 6B QPSK TS Demodulator 1set e User manual 1 pc e Dual Q9 ends coaxial cable 4 pc e AC power line 1 pc In case of any discrepancies please contact the dealer at once 1 2 Installation Following below steps once you are ready to install the device The every details of installing will be described in rest of this chapter please refer to the panel instructions for the specific location This chapter includes the following e Check any possible losing or damage occur during the transport e Get ready the good environment for installation e Install JKDH 6002 6B QPSK TS Demodulator e Connect to the signal lines e Connect to the communication port optional 1 2 1 Device installation flow chart as following Connecting Acquisition Fixing REW Connecting Setting Running Check Device P Signal Wire Parameter Device ower Cord 5 Chengdu Jiexun Electronics Co Ltd Teleph
5. al 2 Alarm for alarm Red indicator turn on when output stream overflow 3 If Lock indictor not on light it means the device work abnormal once it lighting green the device working normal 3 2 Trouble Shooting 1 Power indicator not on light Please check the power cord if inserted into the power socket correctly or the power switch is in the status of ON or OFF 2 Alarm lighting Please check the stream of the 6 programs and total value of the stream increas the output stream value 11 Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 3 Lock not on light The device working abnormal it is fault alarming Please check the connection wire of LNB IN and the parameter value according to the channel number is right or wrong so that to do trouble shooting 12 Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com
6. an insert one end into power supply outlet while insert the other end to AC power e Connecting Grounding Wire When the device solely connects to protective ground it should adopt independent way say share the same ground with other devices When the device adopts united way the grounding resistance should be smaller than 1Q Caution Before connecting power cord and LNB line to JXDH 6002 6B QPSK TS Demodulator make sure have set the power switch to OFF 1 4 Signal Wire Connection The signal line connections include the connection of input signal wire and the connection of output signal wire The input signal line connect with the demodulator LNB IN ASI output port should connect with coaxial cable which witch dual Q9 ends ASI input connection wire Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 1 4 1 ASI input connection Find the ASI output interface according to the rear panel instruction connect one end of the dual Q9 ends coaxial cable to the ASI output port the other end of the cable connect to the ASI input interface of TS multiplexer or modulator such devices illustration as following Charter 2Front panel keybord function introduction 2 1 Keyboard function Left Right Move cursor Up Down Modify parameters Enter Confirm and store modification also for select Menu Circle main menu and channel
7. one 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 1 2 2 Environment requirement Item Machine hall space Machine hall floor Environment temperature Relative temperature Pressure Door amp window Wall Fire protection Power Requirement When many arrays machine cabinets there make sure 1 2 1 5m door to door between one cabinet to another distant the wall at least 0 8m Electric Isolation Dust Free Volume resistivity of ground anti static material 1x10 1x10 9 Grounding current limiting resistance 1MQ Floor bearing should be greater than 450Kg m 5 40 C sustainable working 0 45 C short time working To install air conditioning is recommended 20 80 sustainable working 10 90 short time working 86 105KPa Installing rubber strip for sealing door gaps and dual level glasses for window It can be covered with wallpaper or brightness less paint but do not paint easy pulverable paint Fire alarm system and extinguisher Requiring device power air conditioning power and lighting power are independent to each other Device power requires AC power 220V 50Hz Please carefully check before running 1 2 3 System grounding requirement e All function modules good grounding designs are the base of reliability and stability of device Also they are the most important guarantee of lightning arresting and in
8. rk Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 1 3 Performance Indicator Model JXDH 6002 6B QPSK TS Demodulator Input Frequency 950 2150MHz Signal level 72 22dBm IF band width 27 36MHz Modulate mode QPSK DVB S Input port 75Q British system F head Loop output 75Q British system F head ASI socket BNCTS Package 188 204 bite Optional format Output one group two same outputs Multiplexed and selected output port PID amount Management Ethernet port RJ45 10 100M self adaptive 44mmx482mmx330mm Normal 0 45 C work 20 80 C store attribute 110 220VAC 10 50 60Hz Electrical source 35W port Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 1 4 System Components and Principle 1 4 1 System components JXDH 6002 6B QPSK Demodulator Tuner Module Demodulate Module Tuner Module Demodulate Data Module Processing TS Main output Output i Module Interface Demodulate Module TS input 6 Power 1 4 2 Working principle LNB input 1 LNB input 2 LNB input 5 TS Backup output Tuner Module 1 4 2 1 Tuner Satellite signal input via LNB frequency range at 950 2150 MHz after high precision digital tuner comes corresponding IQ
9. ss ctup physical address 10 EE FO EE ED ED Restore to factoty Language select setting xH English Restore to factoty setting Confirm exit Demodulator Ver 2 8 2 3 1 Operation instruction 1 In main screen press menu button it displays Setup IP address Setup submask Move cursor down to the front of Set IP Address press enter button enter into screen as below Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator Setup IP address 101 101 101 010 Move Left Right button and Up Down button modify the parameter to the value you want to set then press enter button to confirm it displays Saving Done means modified successful Press menu button to return 3 Go on moving down the cursor to the front of Setup submask press enter button it displays Set submask 255 255 255 000 Move Left Right and Up Down button modify the parameter to the value you want to set then press enter button to confirm it displays Saving Done means modified successful Press menu button to return 3 Go on moving down the cursor to the front of Se physical Address press enter button it displays Setup physical address 10 EE FO EE ED ED Move Left Right and Up Down button modify the parameter to the val
10. terference rejection Therefore system must follow this rule e Coaxial cable s outer conductor and isolation layer should keep sound electric conducting with the metal housing of device e Grounding conductor must adopt copper conductor in order to reduce high frequency impedance and the grounding wire must be as thick and short as possible e The 2 terminals of grounding wire must make sure for well electric conducting and process for antirust e It is prohibited that users use other devices as part of grounding wire s electric circuit e The section of the conjunction between grounding wire and device s frame should be equal or greater than 25mm Chengdu Jiexun Electronics Co Ltd http www jie xun com Telephone 028 82000090 9 E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator 1 2 4 Frame grounding All the machine frames should connect to protective copper strip The grounding wire should be as short as possible and avoid circling The section of the conjunction between grounding wire and grounding strip should be equal or greater than 25mm 1 2 5 Device grounding Connecting the device s grounding rod to frame s grounding strip with copper wire 1 3 Wires Connection The power supply outlet is located at the left of rear panel and the power switch is just above it The protective grounding wire connective screw is located at the down left side of power supply outlet e Connecting Power Cord User c
11. ue you want to set then press enter button to confirm it displays Saving Done means modified successful Press menu button to return 4 Go on moving down the cursor to the front of Select Language press enter button It displays Select Language rj English Move Left Right button the language marked with symbol star will be the selected language press enter button to confirm press menu button to return 5 Go on moving down the cursor to the front of Factory settings press enter button it displays 10 Chengdu Jiexun Electronics Co Ltd Telephone 028 82000090 9 http www jie xun com E mail jx3 jie xun com JXDH 6002 6B QPSK Demodulator Factory Settings Confirm Exit 55 Move Left Right button when star symbol point to Exit press enter button will not back to factory setting conversely is confirm to back to factory setting Press menu button to return 6 Go on moving down the cursor to the front of About System press enter button it displays DemoduLator 6 Ver2 8 Press menu button to return 2 3 2 Network management details refer to its User Manual Charter 3 System errors and Debugging 3 1 Status of indicator lights There are 8 LED indicators on the front panel as below 1 Power for power Green when turn on power switch indicator lighting means the device working norm
Download Pdf Manuals
Related Search
Related Contents
Display Side Hi-Fi Component System Avalon Stoves Avanti PS Stove User Manual ECONCEPT Tech Micro Instrucciones ALTO MKII 200 - Allegro Concepts Instrucciones de servicio 558 77 Célula fotoeléctrica (558 77) Zebra MC40 Tecumseh VSC5542ENA Performance Data Sheet Guía del usuario Copyright © All rights reserved.
Failed to retrieve file