IDS X64 LCD Keypad User Manual 700-411-01C
Contents
1. ZONE NAME Enter the User Program Mode as per steps 1 4 of section 8 2 The LCD display reads Option Menu Add User Code To select menu option 30 Edit Zone Name press the 3 0 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want Press the key The LCD display reads Zone Names lt gt Zone Num Enter the ZONE No followed by the key Press the key to begin entering the zone name A blinking character indicates that that character is currently selected for editing Enter the ZONE NAME followed by the key wn NOOK oo NOTE Pressing a key once will display the first letter on the key Pressing a key twice will display the second letter on the key etc Numbers will be displayed once all the letters listed on the key have been displayed The PANIC and MED keys may be used to scroll right or left through the name respectively The MODE key is used to toggle between upper and lower case Pressing the key will reset the zone name to Zone Number if a character has been entered If no character has been entered then pressing will exit zone name programming and return to the options menu Repeat steps 5 7 if more zones are to be named 10 Press the key to exit the User Program Mode NOTE When you are at step 6 entering a zo
2. PROPERTY NUMBER 1 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 10 Code Properties press the 1 0 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads User Code 6 Enter the USER CODE followed by the key ve Enter the PROPERTY NUMBER followed by the key or use the PANIC or MED keys to scroll through the User Options that can be assigned to a user 8 Pressing the key toggles between Y and N for the selected user option 9 Press the key twice to exit User Program Mode EXAMPLE To enable a User Code to function as a duress code when prompted for the option press the 2 key followed by the key IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 8 Table 2 User Code Properties 1 Master User Global Arm Disarm Programmable Output Code 2 Duress Code 3 Arm to Disarm Code Maid s Code 4 Arm Code 5 Disarm Code 6 7 Explanation of User Code Properties 8 3 7 1 Master User When assigned to a user this property allows the user to act as a Master User 8 3 7 2 Duress Code gt This is a special 4 default or 6 digit user code check t
3. INHEP DIGITAL SECURITY X Series LCD Keypad User Manual Protecting your future Series WIRELESS South Africa s leading manufacturer and distributor of electronic security products 2 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 1 Introduction to the IDS X Series LCD Digital Keypad ooiniicinninninnnnnnicnicciccnacniccocnornccccnnnanno 7 2 Viewing Violated ZONES cuicos Oca roo rote 7 3 Arming the Control Panel unico ace 3 1 AWAY ATIN Pt s2s 02352teetd ener EEA EEE EAA E EE aaa au a okawonemenay 3 1 1 How to Away AMM 3 1 2 Quick Away Arm Shortcut Key 3 2 Stay AMIN iii ia 3 2 1 How to Stay AMM eee 3 2 2 Quick Stay Arm Shortcut Key 3 3 How to Stay AMOO GOs vsicctsececaces covcecss est dog 3 4 Key Switch or Remote Arming If fitted a 3 5 Auto AMINO estricta aaa 10 4 DIS eo 4 1 How to Disarm with a User Code 4 2 How to Disarm using a Key Switch or Remote 5 BIS LON en nre nne aa a e nde aed ences ee cent 5 1 How to Bypass Un bypass a Zone 6 Emergency Alarms ccoo aia da Ea 12 6 1 Fire Alarms n 12 6 2 Panic Alarms 12 6 3 edical Alarms 12 6 4 Duress Alar MiSs cinc rd ini a e a cab ciate pth pe 13 7 Alarm Memory 7 1 Event Log 8 A ee 14 8 1 Adding Deleting and Editing User Codes 14 8 2 How to Enter the User Program Mode 15 8 3 Explanation of Programmable Options 15 8 3 1
4. areas covered by motion detectors If necessary bypass any required zones and close the front door Press the key 3 Enter a valid USER CODE If an incorrect code is entered the keypad buzzer will beep three times In the event of an error press the key and re enter the code 4 The ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay The LCD display will read Exit Delay alongside the partition number that is being armed Any bypassed zones will be displayed on the LCD display as solid text Any violated zones will be displayed on the LCD display as flashing text To scroll through zones which have been bypassed or violated use the PANIC and MED keys 5 Leave only via a designated exit route The panel will away arm at the end of the exit delay if any enter exit zone is violated e g the front door 6 Once the panel has armed the LCD display will read Armed alongside the partition that has been armed 3 1 2 Quick Away Arm Shortcut Key Hold down the 1 key until the keypad buzzer sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key The LCD display will read Exit Delay alongside the partition number being armed The keypad buzzer sounds and the arming process begins NOTE If the partition is already STAY armed this key will initialize AWAY arming It is therefore possible to change directly from STAY
5. Alarm Code if programmed will be reported to the monitoring company gt It is advisable to choose a Duress code that can be easily remembered by everyone 7 Alarm Memory The Alarm Memory displays any zones that were tampered violated or bypassed during the last arm cycle A flashing ARM LED notifies the user of an Alarm Memory condition To view the Alarm Memory disarm the panel and continue as follows Hold down the 0 key for two seconds until the keypad buzzer sounds Hold down 0 until the keypad buzzer beeps The ARM and POWER LEDs will turn off and the keypad buzzer will sound briefly Use the MED or PANIC keys to scroll through the zones violated during the last armed period Press the 1 key to return to violated zones Press the 2 key to display zones that were bypassed Press the 8 key to display which zones were tampered Press the 6 key followed by the key to view the event log The Alarm Memory is erased at the beginning of each arm cycle ANOaARWNM 7 1 Event Log When you view event logs the LCD display reads as follows HH MM DD MM YYYY eeeeeeeeee p ddd Where HH MM event time MM DD YYYY event date eeeeeeeeee event description p partition event occurred in if applicable ddd event data if applicable 1 The system time and date need to be setup correctly in order for the event log to pull the correct information These can be setup in o
6. Option 0 Add a New User Code 15 8 3 2 Option 1 Edit a Selected User Code 15 8 3 3 Option 2 Delete User Code Code known 16 8 3 4 Option 3 Add Edit Code 16 8 3 5 Option 4 Delete a User Code Slot known 16 8 3 6 Option 5 View a User Code Slot Number 17 8 3 7 Option 10 User Code Properties 17 8 3 7 1 Master USE A 18 8 3 7 2 Duress Code 18 8 3 7 3 Maid s Code 18 8 3 7 4 AIM wees 18 8 3 7 5 DA 18 8 3 7 6 Global Arm Disarm Code 19 8 3 7 7 Programmable Output Code cece 19 8 3 8 Option 11 Assign User Code to Partitions 19 8 3 9 Option 13 USerOQUIBUISA tr ez 19 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 8 3 10 Option 14 User Reporting Codes Enable oocioinininnnnicninnncccoocioconc circa 8 3 11 Option 15 User Reporting Code Telephone Modules ved 8 3 12 Option 30 Edita Zone NaMe son cee oh Da aa 8 3 13 Option40 EqItINGMIME g a 8 3 14 Options i EqtthSID RO 9 MU e 9 1 How to Select a Stay Pro 9 2 How to Program Cance 10 BUZZ MES na ade EEIE TE E 24 10 1 How to Program Caneel Buzz Zones tuerca r E 25 11 OIM LN e a ceeerer eee rece e ere ecient ere e eatery erence 25 11 1 How to Program Cancel Chime ZONES a cannot a EEEE 25 12 Viewing Trouble Conditions preto N E E 26 13 CHANGING A Paria 26 14 Ottp t Contol Vara Keypad ssn ea e r NE E 27 Tables
7. Tablet USERNAME SEE 14 Table 27 User Code Properties mucosa 18 Table 3 Output Address Physical Mapping Data arcano 20 Table 4 Qutput Actions Data odia 20 Table 5 Enable User Reporting Codes ene Table 6 Specify which Telephone Module to USC ecceeccccceeceeceeceeeeeeeeteeeeeceeeeeeseeeteeteseeeseeteeseeeteeneenees 21 Table 7 POUDE COnGItOns 22 o ees ee at hl death betwee bis Sh tee ce 26 4 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 CONTROL KEYPAD POWER INDICATOR RED This indicator is illuminated when mains power is present ARMED INDICATOR RED The indicator is illuminated when the system is armed MODE KEY Used to switch between partitions and toggle between upper and lower case FIRE ALARM This key will activate the FIRE ALARM when held down for one second PANIC ALARM This key will activate the PANIC ALARM when held down for one second This key can also be used for scrolling MEDICAL ALARM This key will activate the MEDICAL ALARM when held down for one second This key can also be used for scrolling STAR KEY Used to select and de select or when held down for 2 seconds to enter the Main Menu HASH KEY A Cancel or Exit key IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 CONTROL KEYPAD POWER INDICATOR RED ARMED INDICATOR RED This indicator
8. and MED keys to scroll through zones that have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a designated exit route 2 At the end of the exit delay the ARM LED will come on and the display will read Stay Armed All stay zones will be bypassed Key Switch or Remote Arming lf fitted 1 Ensure that the LCD display reads Ready to Arm before leaving 2 Leave the premises and lock the door 3 Activate the remote or the key switch A remote can be used to Stay Arm or Away Arm 4 The alarm will arm in the away mode NOTE If a remote control is used it is advisable to have the siren toot on arm function enabled This provides verification that the system has armed 3 5 Auto Arming The panel may be programmed to arm automatically at a pre programmed time Should the premises be occupied at the time of auto arming a valid USER CODE entered during the pre arm delay will terminate the arming sequence The pre arm delay is signalled by an exit beep IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 4 4 Disarming the Control Panel 4 1 How to Disarm with a User Code USER CODE 1 Enter the premises through a designated entry route Entering via any other route will cause an alarm 2 As soon as the Entry Exit zone is violated the entry delay will begin The keypad buzzer will sound
9. the keypad buzzer sounds The user is alerted to a trouble condition via the flashing of the POWER LED It is also possible to enable a trouble beep If the trouble beep has been enabled the keypad buzzer will sound to alert the user that a trouble condition has occurred Press the key to silence the buzzer Hold down the 7 key for two seconds The LCD keypad will display what the trouble conditions are The system will automatically exit the TROUBLE VIEWING MODE after one minute Alternately to exit this mode press the key NOTE Certain trouble conditions will only clear once the trouble condition has restored To cancel the beeping without viewing the trouble conditions press the key Table 7 Trouble Conditions Zone LED Trouble Condition 1 Panel AC Supply Failure 2 Panel Communications Failure 3 Telephone Line Trouble 4 Siren Tamper 5 Low Battery 6 7 8 Aux 12V Resettable Fuse Blown Engineer reset Box tamper 9 Peripheral Device Tamper 10 Peripheral Communications Failure 11 Peripheral Low Supply Voltage 12 EEPROM chip failure 13 anging a Partition MODE 1 PARTITION NUMBER Tochange partitions the keypad must be assigned to access the required partition Hold MODE until the keypad beeps The LCD display reads Mode Number Press the 1 key followed by the key The LCD display reads Partition Enter the PARTIT
10. zones otherwise it will display V zone Number zone name for about 3 seconds for each violated zone EXAMPLE If there are no zone violations the keypad will alternate flashing between P1 Ready to Arm and P1 Ready 10 01 If there is a zone violation the keypad will alternate flashing between P1 Not Ready and P1 Not Rdy 10 01 with VO5 Zone 05 flashing underneath NOTE P1 indicates the partition number VO5 indicates the zone number that has been violated 10 01 indicates the time The other way mimics the LED keypad It displays both the normal and violated zones of 64 zones simultaneously A centred dot will represent a normal zone and a full black flashing rectangle will represent a violated zone offcecccceee eee eee 2051 1 ccoccce foceceee 0000000000000 00 2010535 48 00000000000000090 Zon549 64 O Unviolated g Violated The above figure shows that zones 2 23 and 24 have been violated The display options are 1 for LCD mode with the scrolling text or 2 for LED mode IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 3 Arming the Control Panel 3 1 Away Arming 3 1 1 Howto Away Arm 4 USER CODE Leave via Entry Exit Zone 1 Ensure that the LCD display reads Ready to Arm alongside the partition number being armed If not check that all protected doors and windows are closed and that all movement has ceased in
11. 0 New Code Change a User Code Master Code 1 Old Code New Code Delete a User Code Code Known Master Code 2 User Code Add Edit Slot Master Code 3 Slot Number User Code Delete a User Code Slot Known Master Code 4 Slot Number View a Slot Number Master Code 5 User Code Edit User Code Properties Master Code 1 0 User Code Property Number Allocate a User Code to a Partition Master Code 1 1 User Code Partition Number E 4 User Outputs Master Code 1 3 User Code Output Number Output Action User Reporting Codes Enable Master Code 1 4 User Code Bitmap User Reporting Code Telephone Master Code 1 5 User Code Bitmap Edit a Zone Name Master Code 3 0 Zone No Zone Name Edit the Time Master Code 4 0 Time Edit the Date Master Code 4 1 Date Change Partitions Mode 1 Partition Number Select a Stay Profile Mode 2 Profile Number Program Cancel Stay Zone 8 Zone Number Program Cancel Buzz Zone 4 Zone Number Program Cancel Chime Z
12. 0 Section 9 9 1 How to Select a Stay Profile MODE 2 PROFILE NUMBER Hold MODE down for one second until the keypad beeps twice The LCD display reads Mode Number Press the 2 key followed by the key The LCD display reads Profile Press 1 2 8 or 4 for the required profile followed by the key The buzzer will give a long beep Program STAY and BUZZ zones for the profile or ARM the profile See sections 9 amp 10 9 2 How to Program Cancel Stay Zones 3 ZONE NUMBER NOaORWNM 1 Select the required stay profile See section 9 1 2 Hold down the 3 key until the keypad buzzer sounds 3 The LCD display read Zone Number 4 Press the ZONE NUMBER corresponding to the zone you wish to be a Stay zone followed by the key Alternatively use the PANIC or MED keys to scroll through the zones 5 A Y next to a zone number indicates that that particular zone is programmed as a stay zone 6 Press the key to toggle between YES and NO NOTE Buzz zones will be shown by flashing LEDs See Section 10 A Buzz zone cannot be selected as a Stay Zone The Buzz status must be cleared first 7 Repeat steps 4 6 until the all the required Stay zones are programmed cancelled 8 Press the key to exit the Stay zone programming mode 10 Buzz Zones Violation of a buzz zone when Stay Armed will cause the key
13. 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 8 oo To select menu option 4 Delete Slot press the 4 key or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want Press the key The LCD display reads Slot Enter the SLOT NUMBER for the User Code you wish to delete followed by the key Further User Codes may be deleted by repeating step 5 Press the key to exit User Program Mode SONOS 8 3 6 Option 5 View a User Code Slot Number MASTER CODE 5 USER CODE 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 5 View Slot press the 5 key or alternatively use the PANIC or MED eys to scroll through the list of programmable options until you reach Menu Option 5 Press the key The LCD display reads User Code Enter the USER CODE followed by the key the slot number is displayed on the keypad Further slot numbers may be viewed by repeating step 5 Press the key to exit the User Program Mode NOOK 8 3 7 Option 10 User Code Properties MASTER CODE 1 0 USER CODE
14. 10 Section 8 5 The LCD display reads User Code 6 Enter the USER CODE followed by the key 7 The LCD display reads Output No 8 Enter the OUTPUT No followed by the key 9 E E The LCD display reads Action 10 Enter the OUTPUT ACTION followed by the key 11 Repeat steps 6 10 until all the user outputs have been entered 12 Press the 4 key to exit the User Program Mode Table 3 Output Address Physical Mapping Data 00 Disabled 21 Reserved 01 Onboard output 1 22 Reserved 02 Onboard output 2 23 Reserved 03 Onboard output 3 24 Reserved 04 Onboard output 4 25 Reserved 05 Onboard output 5 26 Reserved 06 Zone expander 1 output 1 27 Reserved 07 Zone expander 1 output 2 28 Reserved 08 Zone expander 2 output 1 29 Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone expander 3 output 2 32 Reserved 12 Zone expander 4 output 1 33 Reserved 13 Zone expander 4 output 2 34 Keypad 1 outpu 14 Zone expander 5 output 1 35 Keypad 2 outpu 15 Zone expander 5 output 2 36 Keypad 3 outpu 16 Zone expander 6 output 1 37 Keypad 4 outpu 17 Zone expander 6 output 2 38 Keypad 5 outpu 18 Reserved 39 Keypad 6 outpu 19 Reserved 40 Keypad 7 outpu 20 Reserved 41 Keypad 8 outpu Table 4 Output Actions Data 00 Set Output High Set 01 Set Output Low Res
15. ION NUMBER followed by the key The LCD display reads P number DBRN The keypads may be partitioned to remain in the new partition Any value outside of these constraints will result in a key entry error occurring IDS X series LCD Keypad User Manual 700 411 01D Issues August 2010 Section 14 14 Output Control via a Keypad MODE 8 OUTPUT NUMBER If the panel has been setup to control switching functions via its outputs these can be controlled via the keypad e g turning lights on and off NOaORWNM 8 Ensure t triggerin Hold MODE down for one second until the keypad beeps twice The LCD display reads Mode Number Press the 8 key followed by the key The LCD display reads Output Num Enter the OUTPUT NUMBER followed by the key Press the key to toggle between ON and OFF Repeat steps 5 6 to program any other outputs Press the key to exit hat you have checked with your Installer which outputs are used for radio reporting to prevent the g of false alarms IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 28 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 30 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Quick Reference User Guide Add a User Code Master Code
16. Keypad User Manual 700 411 01D Issued August 2010 Section 8 are disarmed and others armed entering this group code at the keypad of the armed partition will disarm the armed partitions only 8 3 7 6 Global Arm Disarm Code This code will either arm or disarm the partitions assigned to that user depending on their status If both partitions are disarmed entering a global code will arm both partitions If more than one partition is armed entering a global code will disarm them In the case where one partition is armed and another is disarmed entering a global code at the keypad of the armed partition will disarm that partition and entering a global code at the keypad of the disarmed partition will arm that partition 8 3 7 7 Programmable Output Code Any event which is able to trigger a programmable output can be assigned to an output number from 1 to 41 Assigning an event to outputs 1 to 5 will use the panel s onboard outputs 1 to 5 Assigning an event to outputs 6 to 25 will use an output on a zone expander or keypad 8 3 8 Option 11 Assign User Code to Partitions MASTER CODE 1 1 USER CODE PARTITION NUMBER f Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 11 User gt Partitions press the 1 1 keys or alternatively use the PANIC or MED keys to scroll through the lis
17. MED keys Quick Select Method Press the 5 key simultaneously with the PROFILE NUMBER and release 1 Ensure that the Panel is disarmed 2 Press the key to clear any previous entries 3 Press the 5 key and then simultaneously press keys 1 2 8 or 4 depending on the stay profile you want to choose then release both keys 4 A beep will sound to indicate successful selection of a profile 5 Program STAY and BUZZ zones for the profile see sections 9 and 10 and or ARM the profile with the 5 key IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 3 3 3 How to Stay Arm and Go Hold down the 6 key for two seconds until the keypad buzzer sounds This is a single key arm function which allows the user to STAY arm and leave the premises If a partition is already stay armed holding down the 6 key initiates an exit delay thus allowing the user to leave the premises without disarming At the end of the exit delay the partition will re arm in the same stay profile it was armed in before the 6 key was held down 1 Make sure all zones are clear Hold down the 6 key until the keypad buzzer sounds The LCD display reads Exit Delay alongside the partition number being armed Any zones that have been bypassed will be displayed on the LCD display as solid text Any zones that are violated will be displayed on the LCD display as flashing text Use the PANIC
18. a Zone Hold down 9 until the beep then enter USER CODE ZONE NUMBER Ensure the panel is not armed To enter bypass mode hold down 9 until the beep The LCD display reads User Code Enter the USER CODE followed by the key AON IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 5 5 The LCD display reads Zone Number 6 Enter the ZONE NUMBER followed by the key Alternatively you can use the PANIC and MED keys to scroll through the zones 7 Y next to the zone number indicates that the zone has been bypassed whilst N indicates that the zone has not been bypassed 8 Press the key to toggle between zones being on and off Repeat steps 6 8 to bypass un bypass other zones 10 Press the key to exit the bypass mode NOTE Panic zones cannot be bypassed 6 6 1 Fire Alarms Hold down the F key for two seconds until the keypad buzzer sounds gt If the F key is pressed until the keypad beeps approximately 2 seconds a FIRE ALARM condition will be activated The LCD display reads Alarm alongside the relevant partition gt The FIRE ALARM CONDITION may also be triggered by a smoke detector connected to an appropriately programmed zone gt The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company gt To si
19. ads Option Menu Add User Code 3 To select menu option 2 Delete User Code press the 2 key or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach Menu Option 2 Press the key 4 The LCD display reads User Code 5 Enter the USER CODE to be deleted followed by the key Deleting the code in slot one will reprogram it to 1234 6 Further codes may be deleted by repeating step 5 7 Press the key to exit User Program Mode 8 3 4 Option 3 Add Edit Code MASTER CODE 3 SLOT NUMBER USER CODE MES Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code To select menu option 3 Add Edit Slot press the 3 key or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want Press the key The LCD display reads Slot Enter the SLOT NUMBER to be added edited followed by the key The LCD display reads New Code Slot number Enter the USER CODE followed by the key Further slots may be added edited by repeating steps 6 8 0 Press the key to exit User Program Mode wo 30NXOD0O A 8 3 5 Option 4 Delete a User Code Slot known MASTER CODE 4 SLOT NUMBER
20. armed to AWAY armed 3 2 Stay Arming Stay arming allows the user to monitor selected perimeter zones and bypass interior zones The user can remain on the premises with access to designated areas during the STAY ARM cycle Any zone that may be violated accidentally should be programmed as a buzz zone When violated a buzz zone will cause the keypad buzzer to sound for 30 seconds before sounding the siren Entering a valid user code before the siren sounds prevents an alarm condition from being registered and will silence the keypad buzzer and prevent the siren from sounding 8 IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 Section 3 To provide greater flexibility the panel caters for the programming of four different STAY PROFILES Each STAY PROFILE contains a unique combination of STAY BUZZ and ALARM zones that cater for a particular STAY ARM requirement EXAMPLE PROFILE 1 might be used when the family goes to bed in the evening In this profile some interior zones may be programmed as alarm zones or buzz zones whereas PROFILE 2 is utilised while watching television when all interior zones would be bypassed See section 9 1 How to Select a Stay Profile 3 2 1 Howto Stay Arm USER CODE Do not leave premises 1 Select the required STAY PROFILE See Section 9 1 2 Ensure that the LCD display reads Ready to Arm alongside the partition number being armed If not check that all protected d
21. be signalled by means of an error beep 3 short beeps If an error beep occurs press the key to clear all previous entries and repeat steps 1 4 6 Further codes can be added by repeating step 4 above When a user code is added it is stored in the first available user slot 7 Press the key to exit the User Program Mode 8 3 2 Option 1 Edit a Selected User Code MASTER CODE 1 OLD CODE NEW CODE 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 8 3 To select menu option 1 Edit User Code press the 1 key or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads Old Code 6 Enter the USER CODE you wish to edit followed by the key 7 The LCD display reads New Code 8 Enter the NEW CODE followed by the key To move the cursor within the NEW CODE use he PANIC or MED keys 9 To edit other codes repeat steps 5 7 10 Press the key to exit the User Program Mode 8 3 3 Option 2 Delete User Code Code known MASTER CODE 2 USER CODE 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display re
22. e interface that allows delete user codes See Table 1 for a summary of programmable options The accessed by entering the USER PROGRAMMING MODE Table 1 User Programming Options ows for the deletion of a user code his is a bitmapped menu is is a bitmapped menu ows for the editing of the date the user to add modify or programmable interface is Allows for the adding editing of the user code slot ows for the deletion of a user code using the user code slot number A h e Allows for the viewing of the user code slot number for a selected code There are 128 available user code slots ows for the editing of the user code properties for a selected user code Allows for the allocation of a selected user code to a designated partition s Th 14 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 8 How to Enter the User Program Mode 1 Ensure that the panel is not armed 2 Hold down the key until the keypad buzzer sounds 3 The LCD display reads Master Code The factory default is 1234 Should the MASTER USER CODE be set to six digits it will be 123456 by default 4 Enter the MASTER USER CODE followed by the key A valid entry will be confirmed by a ong beep If an invalid MASTER USER CODE was entered the keypad buzzer will give an error beep 3 short beeps 5 The first menu option Optio
23. et 02 Pulse Output High 03 Pulse Output Low 8 3 10 Option 14 User Reporting Codes Enable MASTER CODE 1 4 USER CODE BITMAP Enter the User Program Mode as per steps 1 4 of section 8 2 3 The LCD display reads Option Menu Add User Code 3 To select menu option 14 User RC Enable press the 1 4 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Po EN ZONDA O Section 8 Press the key The LCD display reads User Code Enter the USER CODE followed by the key The LCD display reads RC Option Enter the BITMAP that you want followed by the key Press the key to toggle between ON and OFF Press the key to exit the User Program Mode Table 5 Enable User Reporting Codes 8 3 11 On Off 1 O Enable close RC OFF Disable close RC 2 O Enable stay close RC OFF Disable stay close RC 3 O Enable open RC OFF Disable open RC 4 O Enable siren cancel RC OFF Disable siren cancel RC 5 O Enable access RC OFF Disable access RC oo ZONDA Option 15 User Reporting Code Telephone Modules MASTER CODE 1 5 USER CODE BITMAP Enter the User Program Mode as per ste
24. for the duration of the entry period 3 Press the key and enter a valid USER CODE If an error beep occurs press the key and re enter the user code 4 Once the system disarms the ARM LED will turn off and the keypad buzzer will stop sounding 5 f no valid user code has been entered prior to the expiry of the entry delay period an alarm condition will be registered 6 f the entry period is too short have your installer change the entry delay period NOTE If a strobe or flashing light has been installed and an alarm condition is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe How to Disarm using a Key Switch or Remote 1 Activate the remote or key switch The blue button on the remote unless otherwise programmed 2 The system will disarm and the remote indicator if installed will turn off If the siren toot on disarm option is enabled the siren will provide a double toot when the panel is disarmed 5 Bypassing Zones gt The term BYPASS is used to describe a zone that has been deactivated i e violation of a bypassed zone is ignored and will not cause an alarm condition gt Once the system is armed it is not possible to bypass zones gt All bypassed zones will be automatically cancelled each time the panel is disarmed and must be re bypassed before the next arming 5 1 How to Bypass Un bypass
25. he code length with your installer and should only be used in the unique situation where an intruder forces one to disarm the system under duress gt When the DURESS CODE is entered the control panel disarms normally however a DURESS REPORTING CODE is transmitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder gt It is advisable to choose a code that can be easily remembered by all family or staff members 8 3 7 3 Maid s Code This code can be used to limit access to the premises A maid s code will only disarm the system if the same code was used for arming If armed with a code other than this code the system will view an attempt to disarm using a maid s code as an invalid entry Any valid user code will disarm the system if it has been armed with a maid s code 8 3 7 4 Arm This code will arm the partitions assigned to the user depending on their status If all partitions are disarmed entering a group code will arm all of the assigned partitions In a case where some partitions are armed and others disarmed entering this group code at the keypad of the disarmed partition will arm the disarmed partitions only 8 3 7 5 Disarm This code will disarm the partitions assigned to the user depending on their status If all partitions are armed entering a group code will disarm all of the assigned partitions In a case where some partitions 18 IDS X series LCD
26. ion 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 41 Edit Date press the 4 1 keys followed by the key or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads New Date 6 Enter the DATE that you wish to edit followed by the key The format is DDMMYY 7 Press the key to exit the User Program Mode 9 Stay Zones Stay zones are those zones that are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms that are protected by Passive Infra Red PIR detectors or windows that may be opened must be bypassed when staying at home Stay zones need only be programmed once Each time the system is armed in the Stay Mode the pre selected stay zones will be bypassed automatically The panel allows for four unique STAY PROFILES to be stored A STAY PROFILE stores a preselected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement If a partition is stay armed using Profile 1 it is possible to toggle the panel arm status directly to stay arm profile 2 by holding the 5 key for two seconds STAY and BUZZ zones can be programmed for each profile once the profile has been selected See sections 9 amp 10 IDS X series LCD Keypad User Manual 700 411 01D Issued August 201
27. is illuminated The indicator is illuminated when mains power is present when the system is armed MODE KEY MEDICAL ALARM Used to switch between This key will activate the partitions and toggle MEDICAL ALARM when between upper and lower held down for one second case This key can also be used for scrolling PANIC ALARM This key will activate the FIRE ALARM when held PANIC ALARM when held down for one second down for one second This key can also be used for scrolling STAR KEY Used to select and de select or when held down for 2 seconds to enter the Main Menu HASH KEY A Cancel or Exit key IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 1 Introduction to the IDS X Series LCD Digital Keypad This elegant and user friendly LCD Keypad will allow you easy ac cess to your security system s functions and information at the touch of a button The 32 character screen will display menus and messages to guide you through the system s operation so please read this manual carefully and have your Installer explain basic system operation 2 Viewing Violated Zones Hold down MODE until the beep then enter 4 DISPLAY OPTION There are two ways in which to view violated zones in real time The first is the standard way that has the scrolling text This way will say P partition number Ready to Arm if there are no violated
28. lence the siren enter a valid USER CODE 2 Panic Alarms Hold down the P key for two seconds until the keypad buzzer sounds gt If the P key is pressed until the keypad beeps approximately 2 seconds a PANIC ALARM condition will be activated The LCD display reads Alarm alongside the relevant partition number gt A PANIC ALARM may also be activated using any FIXED PANIC button or a REMOTE PANIC button if installed gt If the audible panic option has been selected the siren will sound A PANIC ALARM will be transmitted to the monitoring company gt To silence the siren enter a valid USER CODE gt Press the P key only in an emergency situation that requires response by emergency personnel 6 3 Medical Alarms Hold down the M key for two seconds until the keypad buzzer sounds de gt If the M key is pressed until the keypad beeps approximately 2 seconds a MEDICAL ALARM condition will be activated IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 6 The keypad buzzer will beep 5 times A medical reporting code will be reported to the monitoring company Vv 6 4 Duress Alarms DURESS CODE gt This is a special user code that should only be used in the unique situation where an intruder forces one to disarm the system under duress gt When a DURESS CODE is entered the control panel disarms A Duress
29. n Menu Add User Code is displayed by default 6 Select a programmable option from Table 1 One may use the PANIC or MED keys to scroll hrough the menu options 7 Confirm the entry by pressing the key A valid entry is confirmed by a long beep An invalid entry will be signalled by means of an error beep 3 short beeps If an error beep occurs press he key to clear all previous entries and repeat steps 2 6 EXAMPLE To add a new user code enter User Program Mode by completing steps 2 4 as listed above Menu Option O will be displayed on the LCD screen by default Press the key to confirm your entry Once prompted to Enter a User Code input a NEW USER CODE followed by the key Once the user code is programmed enter the next code followed by To exit the program mode press the key For a full list of options refer to Table 1 Programming of these options is explained below 8 3 Explanation of Programmable Options 8 3 1 Option 0 Add a New User Code MASTER CODE 0 NEW CODE 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code As this is the programmable option you require press the key 3 The LCD display reads New Code 4 Enter NEW USER CODE followed by the key 5 A valid entry is confirmed by a long beep An invalid entry will
30. ne number you can use the following options to copy or delete a zone name IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 8 0 Copy All this is used to update the zone names to all keypads connected to the X series Alarm Panel This is used when a keypad has been replaced or a new keypad is added to the panel This can be used when you replace a keypad and want it to display the existing zone names 111 Delete Name this is used to delete the zone name being viewed from the X series Alarm Panel 222 Delete All this option is used to delete all zone names from the X series Alarm Panel 8 3 13 Option 40 Edit the Time MASTER CODE 4 0 TIME mary Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 40 Edit Time press the 4 O keys followed by the key or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads New Time 6 Enter the TIME that you wish to edit followed by the key The format is HHMM 7 Press the key to exit the User Program Mode 8 3 14 Option 41 Edit the Date MASTER CODE 4 1 DATE Enter the User Program Mode as per steps 1 4 of sect
31. one 2 Zone Number Quick Arm 1 Quick Stay 5 Stay Arm and Go 6 Bypassing Un bypassing a Zone 9 Master Code Zone Number Alarm Memory 0 Displays zones violated View Trouble Conditions 2 No Communication 4 Siren Tamper 5 Low Battery 6 12V Aux Fuse 7 Engineer Reset 8 Box Tamper 9 Tamper on Peripheral Device 10 Comms Loss to Peripheral Device 11 Loss of Power to Peripheral Device 12 EEPROM Failure 7 1 AC Mains Fail 3 Phone Line IDS X series LCD Keypad User Manual 700 411 01C Issues August 2010 ra Ganj yaur future WIRELESS Warranty Inhep Electronics Holdings Pty Ltd guarantees all IDS Control Panels against defective parts and workmanship for 24 months from date of purchase Inhep Electronics Holdings shall at its option repair or replace the defective equipment upon the return of such equipment to any Inhep Electronics Holdings branch This warranty applies ONLY to defects in components and workmanship and NOT to damage due to causes beyond the control of Inhep Electronics Holdings such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment NOTE Wherever possible return only the PCB to Inhep Electronics Holdings Service Centres DO NOT return the metal enclosure The X Series LCD Keypad is a prod
32. oors and windows are closed and that all movement has ceased in the areas covered by motion detectors 3 Press the key 4 Enter a valid USER CODE If an incorrect code is entered the keypad will give an error beep In the event of an error press the key and re enter the USER CODE 5 DO NOT violate the Entry Exit zone normally the front door If the Entry Exit zone is violated the system will arm in the AWAY mode 6 The LCD Keypad will read Exit Delay the ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay 7 When the panel arms any STAY zones will be automatically bypassed These are displayed on the LCD display as solid text Any violated zones will be displayed on the LCD display as flashing text To scroll through zones which have been bypassed or violated use the PANIC and MED keys 8 Ensure that you enter only those areas that are bypassed 3 2 2 Quick Stay Arm Shortcut Key Hold down the 5 key for 2 seconds until the keypad buzzer sounds It is possible to STAY arm by holding down the 5 key until the keypad buzzer sounds The panel will immediately arm into stay mode without any exit delay Holding the 5 key again will toggle between the 4 stay profiles The LCD display will read Stay Armed and will indicate any zones that have been bypassed One is able to scroll through the list of bypassed as well as violated zones by using the PANIC and
33. pad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during his period the system will register an alarm condition This feature helps prevent unnecessary false alarms NOTE f an Entry Exit zone is programmed as a buzz zone violation of the Entry Exit zone when the panel is Stay Armed will cause the keypad buzzer to sound for the duration of the entry delay time This if the panel is stay armed allows the user to enter the premises and disarm the panel f it is not programmed as a buzz zone the alarm will be triggered immediately If the panel was armed using the 6 key Stay Arm and Go violation of the Entry Exit zone will always start the Entry Exit delay IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 10 10 1 Howto Program Cancel Buzz Zones 4 ZONE NUMBER 4 1 Select the required Stay Profile See section 9 1 2 Hold down the 4 key until the keypad buzzer sounds 3 The LCD display reads Zone Number 4 Press the ZONE NUMBER corresponding to the zone you wish to be programmed as a Buzz zone followed by the key Alternatively use the PANIC or MED keys to scroll through the zones 5 A Y next to the zone number indicates that the zone has been programmed as a Buzz zone Flashing text indicates a Stay zone 6 Press the key to toggle between YES and NO 7 Re
34. peat steps 4 6 until all the required Buzz zones are programmed cancelled 8 Press the key to exit the Buzz zone programming mode NOTE A zone cannot be both a Buzz and Stay Zone A Stay zone cannot be selected as a Buzz zone 11 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the siren will NOT sound and no alarm condition will be reported EXAMPLE If you wish to know each time someone enters or exits the front door of your office program this zone as a chime zone the keypad will beep each time someone opens the front door 11 1 How to Program Cancel Chime Zones 2 ZONE NUMBER 1 Hold down the 2 key until the keypad buzzer sounds 2 The LCD display reads Zone Number 3 Press the ZONE NUMBER corresponding to the zone you wish to be a Chime zone followed by he key Alternatively use the PANIC or MED keys to scroll through the zones A Y next to the zone number indicates that the zone has been selected as a Chime zone Press the key to toggle between YES and NO Repeat steps 3 5 until all the required Chime zones are programmed cancelled Press the key to exit the Chime zone programming mode NDA IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 12 Hold down the 7 key for two seconds until
35. ps 1 4 of section 8 2 The LCD display reads Option Menu Add User Code To select menu option 15 User RC Modules press the 1 5 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want Press the key The LCD display reads User Code Enter the USER CODE followed by the key The LCD display reads RC Code lt gt Enter the BITMAP that you want followed by the key Press the key to toggle between ON and OFF Press the key to exit the User Program Mode Table 6 Specify which Telephone Module to use 1 ON Telephone Module 2 IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 8 OFF Telephone Module 1 2 ON Telephone Module 2 OFF Telephone Module 1 3 ON Telephone Module 2 OFF Telephone Module 1 4 ON Telephone Module 2 OFF Telephone Module 1 5 ON Telephone Module 2 OFF Telephone Module 1 NOTE The options are only available if the corresponding option in option 14 is on EXAMPLE If the close RC is disabled then you will not be able to set the telephone module for it If it is enabled then you can choose between telephone module 1 and 2 NOTE User options 20 29 can be found in the Remote Receiver Manual P N 700 408 02A 8 3 12 Option 30 Edit a Zone Name MASTER CODE 3 0 ZONE No
36. ptions 40 and 41 2 When the event log menu is entered a reference will be taken of the last event recorded Any event prior to this reference may be viewed by scrolling back with the MED key but if the user decides to scroll forward with the PANIC key then just events up to and including this reference point will be viewable 3 If no event is encountered then the second line will appear as IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 Section 7 No Event 4 Pressing 6 followed by after the event log viewing is already active will reset the menu to the most recent event 5 Each event description will be followed by two numbered fields if further data is applicable to describe an event The first number is the partition number within whi ch the event occurred The second number will either be the zone or user number associated with the event type Below is an example of how an event will be displayed on the two line 02 00 01 01 2010 Violate 2 23 Translates to On 1 Jan 2010 at 2AM zone 23 within partition 2 was vio NOTE DS LCD keypad ated The event log will only show the time and date up to the last power up For a more detailed listing please consult your installer 8 User Codes 8 1 Adding Deleting and Editing User Codes MASTER CODE PROGRAMMABLE OPTION All IDS Alarm Panels utilise a user friendly programmabl
37. t of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads User Code 6 Enter the USER CODE followed by the key 7 The partitions to which the USER CODE is assigned are indicated by options 1 8 If the user is assigned to partition 1 there will be a YES next to option 1 and the user can thus arm and disarm partition 1 If the user is assigned to partition 4 there will be a YES next to option 4 It is possible O program codes to arm disarm any combination of the available partitions 8 Enter the PARTITION NUMBER followed by the key One may also use the PANIC and MED keys to scroll through the partitions 9 Press the key to toggle between YES and NO 10 Repeat steps 8 9 until the User Code has been assigned to the correct partition s 11 Press the key twice to exit the User Program Mode 8 3 9 Option 13 User Outputs MASTER CODE 1 3 USER CODE OUTPUT No OUTPUT ACTION 4 Enter the User Program Mode as per steps 1 4 of section 8 2 The LCD display reads Option Menu Add User Code 3 To select menu option 13 User Outputs press the 1 8 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you Mm 4 Press the key IDS X series LCD Keypad User Manual 700 411 01D Issued August 20
38. uct of IDS Inhep Digital Security and is manufactured by Inhep Electronics Holdings Pty Ltd WARNING For safety reasons only connect equipment with a telecommunications compliance label This includes customer equipment previously labeled permitted or certified This is a professional product and due to the nature of the product should only be installed by an accredited professional Alarm Installer Help Desk Number 0860 705137 Please note that this is NOT a toll free number gt 150 9001 738 New Germany 3620 South Africa 5 info inhep com www inhep com