Compact Data Sheet

image

Contents

1. HVFDCDTRAINER U HVFDCABLE U SmartVFD Commissioning Cable and USB Adaptor HVFDCDMCA U Compact Commissioning Device HVFDCDMCAKIT U Compact Commissioning Kit HVFDCDNEMA1FR1 U Compact NEMA 1 Kit Frame Size1 HVFDCDNEMA1FR2 U Compact NEMA 1 Kit Frame Size2 HVFDCDNEMA1FR3 U Compact NEMA 1 Kit Frame Size3 Compact Training Demonstration Kit 31 00075 01 SMARTVFD COMPACT 31 00075 01 SMARTVFD COMPACT 31 00075 01 SMARTVFD COMPACT By using this Honeywell literature you agree that Honeywell will have no liability for any damages arising out of your use or modification to the literature You will defend and indemnify Honeywell its affiliates and subsidiaries from and against any liability cost or damages including attorneys fees arising out of or resulting from any modification to the literature by you Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Honeywell U S Registered Trademark Golden Valley MN 55422 2015 Honeywell International Inc 31 00075 01 M S 01 15 customer honeywell com Printed in United States
2. Quick Setup Menu Only the most commonly used parameters are visible in basic view to provide easier navigation The full view can be seen after P13 1 Parameter conceal is deactivated by changing the value to 0 Easy navigation through the most common parameters SmartVFD Commissioning Tool 1 Parameter sets can be uploaded and downloaded with this tool 2 Easy to use PC tool for commissioning the SmartVFD Invert ers Connection with HVFDCABLE and MCA adapter HVFD CDMCAKIT U to the USB port of the PC PC tools available for download free of charge from https customer honeywell com en US support commercial software vfds Pages default aspx Parameter copying easily from 1 inverter to another Easy download of parameter sets created with PC tool Parametering with PC Saving settings to PC Comparing parameter settings 31 00075 01 Compact and robust design with easy installation Table 8 SMARTVFD COMPACT Feature Compact size Functions Minimum free space above and below the drive is required for cooling airflow Benefit Minimum space requirements Integrated RFI filters The units comply with EN61800 3 category C2 as standard This level is the required level for public electricity networks such as buildings Easy selection and installation of products Space savings Cost savings Single power rating Single power suitable for both pump and fan or machine applicat
3. Product Identification Code 31 00075 01 4 SMARTVFD COMPACT MECHANICAL DIMENSIONS AND MOUNTING There are two possible ways to mount the SmartDrive Compact onto the wall either screw or DIN rail mounting The mounting dimensions are also given on the back of the inverter MI MI2 3 1 2 A A FT TANS M35444 D1 M35445 Mechanical size H1 H2 H3 wi w2 w3 D1 D2 Moo e2 J5s8 154 Re hs Do2 39 bs MI2 7 7 7 2 6 7 3 5 2 5 0 2 J40 0 3 MI3 10 3 9 9 9 5 3 9 3 0 02 43 0 3 Fig 3 Dimensions in inches 5 31 00075 01 SMARTVFD COMPACT COOLING Forced air flow cooling is used in all SmartDrive Compact drives Enough free space shall be left above and below the inverter to ensure sufficient air circulation and cooling SmartDrive Compact products can be mounted side by side You will find the required dimensions for free space and cooling air in the tables below Table 2 Mechanical size Free space above inches Free space below inches Mi 4 0 2 0 MI2 4 0 2 0 MI3 4 0 2 0 Table 3 Mechanical size Cooling air required CFM MH 5 89 MI2 5 89 MI3 17 7 CABLING AND FUSES Use cables with heat resistance of at least 158 F 70 C The cables and the fuses must be dimensioned according to the following tables The fuses function also as cable overload protection These instructions apply only to cases wit
4. 9 15 9 20 15 20 15 31 00075 01 6 SMARTVFD COMPACT 3 zen zn a CRIT OUT 1 Len La L3 ur wr2 wma V T2 W T3 i ACE 7 El E 1 _ Ca Sl Y STRIP THE PLASTIC CABLE COATING FOR MAINS 360 GROUNDING MOTOR BRAKE 1 gt EN RESISTOR STOR 400V MOTOR OUT E L2 N L3 a R U T1V T2 W T3 REA STRIP THE PLASTIC CABLE COATING FOR 360 GROUNDING M35446 CONTROL CABLE TIGHTENING TORQUE 0 4 Nm STRIP THE PLASTIC CABLE COATING FOR 360 GROUNDING M35447 Fig 5 SmartDrive Compact control connections wiring A12 GND GND Di4 _DI5 _DI6 _AO DO RO1 RO1 __RO2 4 13 14 15 16 18 20 22 23 26 O O O O O O 0 90 O 0 O Oo 1 2 MIG Y em 2 10 25 24 O O Eee O O Q 10V All GND 24V GND D1 DI2 DIS A B RO2 RO2 M35448 Fig 6 SmartVFD Compact control connection terminals 7 31 00075 01 SMARTVFD COMPACT The table below shows the SmartDrive Compact control connections with the terminal numbers API FULL TERMINAL SIGNAL FACTORY PRESET DESCRIPTION REF VOLTAGE OUT MAXIMUMLOAD 10 mA 2 AI A ANALOG SIGNAL FREQ REFERENCE 0 10 V Ri 200 k O MIN N1 5 ende osoon Ss ee 24V OUTPUT FOR Eo 20 MAX LOAD 50 mA DI S 7 feno rose S 8 om DIGITALINPUTI START FORWARD 0 30VRi 12k Q MIN 9 Di2 _ oicimaLiNeuT2 start Reversen to pis pie mpurs preserspeepBo Ca Ja
5. Honeywell SmartVFD COMPACT e san BA COMPACT O DANGER Ee 1 s SmartDrive COMPACT Honeywell SmartDrive COMPACT GENERAL SmartVFD COMPACT variable frequency drives provide step less speed control for various applications Pumps Fans Compressors Conveyors etc FEATURES e Compact size saves space in your equipment cabinet e Flexible side by side mounting with screws or DIN rail as standard e Single rating suitable for both pump and fan or machine applications Maximum ambient temperature 122 F e Integrated RFI filters e Wide input and output connection possibilities e Configurable inputs and outputs e 30 second Start Up Wizard e Easy keypad to remote change with 1 button e Parameter upload download even without main power to the drive with HVFDCABLE accessory Quiet motor operation with 4 kHz switching frequency PRODUCT DATA e Overtemperature ride through Power ride through Automatic restart e Integrated PI controller e Optional NEMA 1 enclosure SPECIFICATIONS Mains Connection Input voltage Uin 115Vac 15 10 1 208 240 Vac 15 10 1 208 240 Vac 15 10 3 380 480 Vac 15 10 3 600Vac 15 10 3 Input frequency 45 66 Hz Connection to mains Once per minute or less Brake chopper Available on MI2 and MI3 with 3 phase units 100 TN with brake option 30 TN without brake option Motor Connection Output vo
6. MC HVFDCD1B0020F01 208 230V 1 HP 3 7A No HVFDCD3B0010F00 3 in 3 out 2HP 7A No HVFDCD3B0020F00 115V 230V 0 25 HP 1 7 A No HVFDCD1A0003F00 1 in 3 out 0 5HP 2 4A No HVFDCD1A0005F00 1 HP 3 7A No HVFDCD1A0010F00 31 00075 01 SMARTVFD COMPACT Nom HP EMC Full IO 6DI 2Al 1AO Nominal Voltage Nom Current Filter 1DO 3RO Modbus Frame Size MI3 Dimensions 10 2 H x 3 9 W x 4 3 D 460V 4 HP 7 6 A No HVFDCD3C0040F00 3 in 3 out EMC HVFDCD3C0040F01 5 HP 9 A No HVFDCD3C0050F00 EMC HVFDCD3C0050F01 7 5 HP 12 A No HVFDCD3C0075F00 EMC HVFDCD3C0075F01 208 230V 3 HP 1 A EMC HVFDCD1B0030F01 1 in 3 out 208 230V 3HP 11 A No HVFDCD3B0030F00 3 in 3 out 115V 230V 1 5 HP 4 8 A No HVFDCD1A0015F00 1 in 3 out 600V 1 HP 2 A No HVFDCD3D0010F00 3 in 3 out 2 HP 3 6 A No HVFDCD3D0020F00 3 HP 5A No HVFDCD3D0030F00 5 HP 7 6 A No HVFDCD3D0050F00 7 5 HP 10 4 A No HVFDCD3D0075F00 PRODUCT IDENTIFICATION CODE HVFDCD 3 C 0000 F O O PRODUCT FAMILY EMC FILTER HVFDCD SmartVFD COMPACT 0 NO FILTER 1 FILTER INCLUDED PHASES ENCLOSURE 1 SINGLE PHASE 1 IN 3 OUT 0 OPEN CHASSIS IP20 3 TRIPLE PHASE 3 IN 3 OUT CONTROL lO NOMINAL VOLTAGE F FULL IO 6DI 142 3DO 1AO A 115V B 208V 230V NOMINAL HORSE POWER 0007 75 HORSE POWER C 480V D 600V 0010 1 HORSE POWER 0100 10 HORSE POWER M35443 Fig 1
7. XXXXX 160VDC in HVFDCDXBXXXXXXX Earth fault protection In case of earth fault in motor or motor cable only the fre quency converter is protected Unit overtemperature protection YES Motor overload protection YES Motor stall protection fan oump blocked YES Motor underload protection pump dry belt broken detection YES Short circuit protection of 24V and 10V reference voltages YES Overcurrent protection Trip limit 4 0 I instantaneously MODELS SMARTVFD COMPACT Table 1 Nom HP EMC Full IO 6DI 2Al 1AO Nominal Voltage Nom Current Filter 1DO 3RO Modbus Frame Size MI1 Dimensions 6 2 H x 2 6 W x 3 9 D 460V 0 5HP 1 3A No HVFDCD3C0005F00 3 in 3 out EMC HVFDCD3C0005F01 0 75HP 1 9A No HVFDCD3C0007F00 EMC _ HVFDCD3C0007F01 1 HP 2 4 A No HVFDCD3C0010F00 EMC HVFDCD3C0010F01 208 230V 0 25HP 1 7A EMC HVEDCD1B0003F01 1 in 3 out 0 5 HP 2 4A EMC HVFDCD1B0005F01 0 75 HP 2 8 A EMC HVFDCD1B0007F01 208 230V 0 25 HP 1 7A No HVFDCD3B0003F00 3 in 3 out 0 5HP 2 4A No HVFDCD3B0005F00 Frame Size MI2 Dimensions 7 7 H x 3 5 W x 4 0 D 460V 15HP 3 3A No HVFDCD3C0015F00 3 in 3 out EMC HVFDCD3C0015F01 2HP 4 3A No HVFDCD3C0020F00 EMC HVFDCD3C0020F01 3 HP 5 6 A No HVFDCD3C0030F00 EMC HVFDCD3C0030F01 208 230V 1 HP 3 7A EMC HVFDCD1B0010F01 1 in 3 out 15HP 48A EMC HVFDCD1B0015F01 2 HP 7 A E
8. h one motor and one cable connection from the inverter to the motor In any other case contact your Honeywell Sales Representative Table 4 Connection Cable type Mains cable Power cable intended for fixed installation and the specific mains voltage Shielded cable not required NKCABLES MCMK or similar recommended Motor cable Power cable equipped with compact low impedance shield and intended for the specific mains voltage NKCABLES MCCMK SAB ZCUY J or similar recommended 360 grounding of both motor and FC connection required to meet the standards Control cable Screened cable equipped with compact low impedance shield NKCABLES Jamak SAB OZCuY O or similar Table 5 Cable and fuse sizes for 208 240 V Terminals cable size min max Main Earth Conirol Relay Type In Fuse Mains cable Cu terminal terminal terminal terminal Size power A A AWG AWG AWG AWG AWG MI2 1P1 1P5 4 8 7 0 20 2x13 13 15 11 15 11 20 15 20 15 MI3 2P2 11 32 2x9 9 15 9 15 9 20 15 20 15 Table 6 Cable and fuse sizes for 380 480 V Terminals cable size min max Main Earth Control Relay Type In Fuse Mains cable Cu terminal terminal terminal terminal Size power A A AWG AWG AWG AWG AWG Mi P37 1P1 1 9 3 3 6 3x15 15 15 11 15 11 20 15 20 15 MI2 1P5 2P2 4 3 5 6 10 3x15 15 15 11 15 11 20 15 20 15 MI3 3P0 5P5 7 6 12 20 3x13 13 15
9. ions Easy selection Max ambient temperature 122 F High maximum ambient operating temperature Uninterruptible operation Side by side mounting with screws or DIN rail as standard SmartDrive Compact can be mounted side by side with no space between the units either with screws or on DIN rail as standard Dimensions for screw mounting can be found also on the back of the inverter Easy installation Space savings Uninterruptible operation functions ride through increase in ambient Table 9 Feature Functions Benefit Overtemperature Automatically adjusts switching frequency to adapt to unusual Uninterruptible operation Power ride through Automatically lowers motor speed to adapt to sudden voltage drop such as power loss Uninterruptible operation Auto restart function Auto restart function can be configured to make VFD restart automatically once fault is addressed Uninterruptible operation VFD and motor control features Table 10 Feature Functions Benefit Flying start Ability to get an already spinning fan under speed control Improved performance Ease of application Inbuilt PI controller Capability to make a standalone system with sensor connected directly to the inverter for complete Pl control Cost saving OPTIONAL ACCESSORIES Table 11 SmartVFD COMPACT Accessories Model Number Description
10. lasas sonaa Fe communem ee rsessiona e recommen Pa a2 ANALOG siena nefer ACTUAL VALUE foa zoma Ri 200K0 5 ono osen is GND vo SIGNAL GROUND PRESET SPEED B1 P 0 30 V Ri 12k Q MIN gt gt o DIGITAL INPUT 4 fis os _ Joismaumeurs rarase fie Jos pena meurs osasco mlo omman oa omaa 20 DIGITAL SIGNALOUT ACTIVE READY OPEN COLLECTOR MAX LOAD 48V 50mA RELAY OUTI JACTIVE RUN MAX SWITCHING LOAD 250Vac 2A OR 250Vdc 0 4A ACTIVE FAULT MAX SWITCHING LOAD 250Vac 2A OR 250Vdc 0 4A P PROGRAMMABLE FUNCTION SEE USER MANUAL PARAMETERS M35449 Fig 7 Control inputs and outputs API Full FEATURES FUNCTIONS Easy to set up features Table 7 Feature 30 second Start up wizard Functions Simple 4 step wizard for specific applications Activate wizard by pressing stop for 5 seconds Tune the motor nominal speed Tune the motor nominal current Select mode O basic 1 Fan 2 Pump and 3 Conveyor Benefit Fully configured inverter for the application in question Ready to accept 0 10V analog speed signal in just 30 seconds Keypad Remote Operation Push the navigation wheel for 5 seconds to move from remote control I O or Fieldbus to manual mode and back Single button operation to change the control to manual keypad and back Useful function when commissioning and testing applications
11. ltage 0 Uin 3 Output current In Continuous output current with max 50 C ambient tem perature overloadability 1 5 x ly 1min 10min Starting current 2 x ly 2s 20s Output frequency 0 320 Hz Frequency resolution 0 01 Hz Control Characteristics Control method Frequency Control U f Open Loop Sensorless Vector Control Switching frequency 1 5 16 kHz default 6 kHz Field weakening point 30 320 Hz Acceleration time 0 1 3000 sec 31 00075 01 SMARTVFD COMPACT Deceleration time 0 1 3000 sec Braking torque 100 TN with brake option only in 3 drives sizes MI2 and MI3 30 TN without brake option Ambient Conditions Operating temperature 14 F 10 C no frost 104 122 F 40 50 C for 115 Vac 460 Vac and 600 Vac and 104 F 40 C for 208 Vac 230 Vac rated loadability In Storage temperature 40 F 40 C 158 F 70 C Air quality Chemical vapors IEC 721 3 3 unit in operation class 3C2 Mechanical particles IEC 721 3 3 unit in operation class 3S2 Altitude 100 load capacity no derating up to 1000 m 1 derating for each 100 m above 1000 m max 2000 m Relative humidity 0 95 RH non condensing non corrosive no dripping water Vibration 3 150 Hz EN50178 EN60068 2 6 Displacement amplitude 1 peak mm at 3 15 8 Hz Max acceleration amplitude 1 g at 15 8 150 Hz Shock EN50178 IEC 68 2 27 UPS Drop Test for applicable UPS weight
12. s Storage and shipping max 15 g 11 ms in package Enclosure class Open chassis NEMA 1 kit optional Electro Magnetic Compatibility EMC Immunity Complies with EN50082 1 2 EN61800 3 Category C2 Emissions 115V Complies with EMC category C4 230V Complies with EMC category C2 with an internal RFI filter 400V Complies with EMC category C2 with an internal RFI filter 600V Complies with EMC category C4 All No EMC emission protection Honeywell level N Without RFI filter 31 00075 01 Safety For safety CB CE UL cUL For EMC CE CB c tick see unit nameplate for more detailed approvals Control connections Analog input voltage 0 10V Ri 200kQ min Resolution 10 bit accuracy 11 electrically isolated Analog input current 0 4 20 mA Ri 20042 differential resolution 0 1 accuracy 1 electrically isolated Digital inputs 6 positive logic 0 30 VDC Voltage output for digital inputs 24V 20 max load 50 mA Output reference voltage 10V 3 max load 10 mA Analog output 0 4 20 mA RL max 5000 resolution 16 bit accuracy 1 Digital outputs Relays 2 programmable relay outputs 1 NO NC and 1 NO Max switching load 250 Vac 2 A or 250 Vdc 0 4 A Open collector 1 open collector output with max load 48 V 50 mA Protections Overvoltage protection 875VDC in HVFDCDXCXXXXXXX 437VDC in HVFDCDXBXXXXXXX Undervoltage protection 333VDC in HVFDCDXCXX