Home
KIEN1005S Industrial Ethernet Switch Hardware Installation Manual
Contents
1. L E L a E 5 La LI T7 L e Remove KIEN1005S from wall or cabinet The specific steps are as follows Step 1 Use a screwdriver to loosen 4 screws move the device up to let screws into 4 holes with the diameter of 6 5mm 46 5 Step 2 Unscrew the screws from wall or cabinet remove the device from wall or cabinet KIEN1005S User s Manual 201110 a a I u T ied o a E apt ci T LS E 5 Cable Connection 10 100Base TX Port RJ45 Port kRJ45 port cable types and requirements 10 100Base TX Ethernet RJ45 port can be connected to terminal equipment with a straight through cable and connected to network devices with a cross over cable e kRJ45 connector and pin number 87654321 Pin distribution of 10 100Base TX Output data TD Receiving data RD Note means cable polarity 100M straight through cable wiring 10 KIEN1005S User s Manual 201110 Switch Network Interface RJ45 Connector RJ45 Connector Wiring sequence TD 6 6 RD RD 1 1 TD RD 2 2 TD 100M cross over cable wiring Switch Cross over cable Switch Network Interface i B Network Interface Pin1 RJ45 Connector RJ45 Connector Wiring sequence RD TD 3 1 iRD TD RD2TD i 6 2 iRD TD TD RD 1 3 TD RD4 TD RD 2 6 TD RD POE Port RJ45 port POE po
2. firmly interconnected and checked frequently Do not repair the equipment by yourself unless it is clearly specified in the manual Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth In the following cases please immediately cut off the power supply and contact our company Water gets into the equipment Equipment damage or shell breakage Abnormal operation of equipment or its performances have completely changed Vv VY V WV The equipment emits odor smoke or abnormal noise KIEN1005S User s Manual 201110 Contents PACKI By cy tetera inert ene eee ler ee ener are re nr UC rc eee eee eee LU E 5 Product OVeEFVIOWLasu ii en cited iban dad nan nomen din nee 5 Structure and Interfdte i ue cm tenete Un E i D TRE E DEDE E 5 MouUNtNE C Q 6 Gable Connec ON CP X X X 10 DIGI CAO ancien cun dota ba n mca i aciei icu if E adt DEL cM c TODA ETEE 16 Product Modessa a 16 Basic Features and SDeCIHCatlO PSone rice vaca doo rien ae nana aie 16 KIEN1005S User s Manual 201110 1 Packing List KIEN1005S Industrial Ethernet Switch 1 Hardware Installation Manual 1 Certificate of Quality including Warranty Card 1 Note After unpacking please check the accessories and the appearance of the equipment If anything is missing or damaged please contact us 2 Product Overview The Kyland KIEN1005S is a series of the green
3. port and 4 10 100Base TX POE ports 8 Basic Features and Specifications Technology IEEE 802 3i IEEE 802 3u IEEE 802 3af 24VDC 48VDC dual redundant power inputs 16 KIEN1005S User s Manual 201110 EMC IEC61000 4 2 ESD 8kV contact 15kV air IEC61000 4 3 RS 10V m 80MHz 2GHz IEC61000 4 4 EFT Power Port 4kV Data Port 2kV IEC61000 4 5 Surge Power Port 2kV DM 4kV CM Data Port 2kV IEC61000 4 6 CS 3V 10kHz 150kHz 10V 150kHz 80MHz IEC61000 4 16 Common mode conduction 30V cont 300V 1s Cable Twisted Pair 100m Standard CAT5 CAT5e network cable Multi Mode Fiber 1310nm 5km 100M Single Mode Fiber 1310nm 40km 60km 100M 1550nm 60km 80km 100M Power Requirements Power input 24VDC 48VDC 22VDC 57VDC Power terminal 5 pin 5 08mm spacing plug in terminal block Power consumption lt 3W no PD lt 70W full load PD 15 4W per POE port Physical Characteristics Installation DIN Rail or wall mounting Dimensions WxHxD 30mmx115mmx91 5 mm Weight 0 5Kg Environment Limits Operating Temperature 40 C to 85 C 40 to 185 F Storage Temperature 40 C to 85 C 40 to 185 TF Ambient Relative Humidity 596 to 9596 non condensing MTBF 353 350 hrs Warranty 5 years 17 KIEN1005S User s Manual 201110 For more information about KYLAND products please visit our website http www kyland cn 18
4. KIEN1005S User s Manual 201110 KIEN1005S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co LTD Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn E mail support kyland biz Publication Date September 2011 Version V1 0 No 1 12 02 1028 0 KIEN1005S User s Manual 201110 KIEN1005S Industrial Ethernet Switch Hardware Installation Manual Disclaimer Kyland Technology Co Ltd tries to keep the content in this manual as accurate and as up to date as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice Copyright 2011 KYLAND Technology CO LTD All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation KIEN1005S User s Manual 201110 Notice for Safety Operation This product performs reliably as long as it is used according to the guidance Artificial damage or destruction of the equipment should be avoided Read this manual carefully and keep it for future reference Do not place the equipment near water sources or damp areas Do not place anything on power cable and put the cable in unreachable places Do not tie or wrap the cable to prevent fire Power connectors and other equipment connectors should be
5. low power consumption DIN Rail POE industrial Ethernet switches that can be applied extensively in security highway monitoring rail transit railway disaster prevention coal mining industrial production and control and many other industrial systems The KIEN1005S industrial Ethernet switch supports DIN Rail and wall mounting It provides one 100M fiber copper optional port and four 10 100Base TX 802 3af compliant POE ports The output power per POE is 15 4W at 24VDC or 48VDC 3 Structure and Interface Front Panel 123 1 PWR1 Power 1 LED 2 PWR2 Power 2 LED E 3 1 100Base FX port LED 4 1 100Base FX port 6 5 5 2 5 10 100Base TX ports 7 6 POE POE LED 7 Link ACT Port Link LED KIEN1005S User s Manual 201110 Top Panel 1 Terminal block for power input 2 Screw hole for grounding 4 Mounting 9 Dimension Drawing for DIN Rail Mounting Unit mm 9 Dimension Drawing for Wall Mounting Unit mm KIEN1005S User s Manual 201110 Note The switch housing is a part of the heat dissipation system which becomes hot during operation Please be careful when handling the device during operation Mounting Steps KIEN1005S DIN Rail Mounting The specific steps are as follows Step 1 Select the mounting position for KIEN1005S and ensure that there is enough space Step 2 Insert the top of the DIN Rail into the spring supported slot of the DIN Rail con
6. necting seat in the rear panel of KIEN1005S as seen below move the device in the direction of arrow 2 to put the whole Din Rail into the seat check whether KIEN1005S is firmly mounted on the DIN Rail as shown below KIEN1005S User s Manual 201110 DIN Rail Remove KIEN1005S from DIN Rail The specific steps are as follows Step 1 Plug the screwdriver into the hole at the bottom of spring locking plate press the plate down to loosen the connection of DIN Rail and switch as shown in arrow 1 Step 2 Take up KIEN1005S in the direction of arrow 2 meanwhile remove the device from the DIN Rail along the direction of arrow 3 KIEN1005S Wall Mounting The specific steps are as follows Step 1 Select the mounting position for KIEN1005S on the wall or in cabinet ensure that there is enough space for the switch Step 2 Drill 4 holes on the selected position according to the wall mounting dimension drawings use a cross screwdriver to screw 4 cross slot screws M3 X 10 into holes 8 KIEN1005S User s Manual 201110 Don t tighten up the screws completely leave about 5mm of space between Step 3 Aim 4 mounting holes on KIEN1005S mounting plate at 4 fixed screws pass the screws through 4 holes with the diameter of 6 5mm 456 5 then slide down KIEN1005 as seen below finally screw 4 screws tightly Now the KIEN1005 should be firmly fixed to the wall or cabinet erei Screw P E Ld a z L
7. ort wiring Take SC port as example ST FC wiring method is the same with SC SC SC cable wiring sequence Note A laser is used to transmit signals in fiber cables The laser meets the requirements of level 1 laser products Routine operation is not harmful to your eyes but do not look directly at the fiber port and fiber connector when the switch is powered on Power According to the power input requirements use a 5 08mm spacing terminal block to connect power cable Note The cross section area of power cable is required to be greater than 0 75mm and less than 2 5mmZ The grounding resistance requirement lt 5Q 13 KIEN1005S User s Manual 201110 iu RR PWR2 5 pin 5 08mm power terminal block O O O O O L IN d IN L 123 45 Contact definition DC wiring definition AC wiring definition o IN PWR2 N 5 PWR2 PWR2 L Grounding Chassis grounding and power terminal grounding Chassis grounding Surge grounding 18 AWG yellow green line There is a grounding screw on the top panel of the KIEN1005S which is for chassis 14 KIEN1005S User s Manual 201110 grounding One end of the chassis grounding cable is connected with the grounding screw and the other end of the cable is reliably earthed The cross section area of chassis grounding cable should be more than 2 5mm2 The grounding resistance requirement lt 5Q 5 08mm power terminal grounding is called su
8. rge grounding It is required to connect the chassis grounding part with the surge grounding part with 18 AWG yellow green line as seen below 18 AWG yellow green line Unit mm a Cy gt A x Hot shrinkage Er sheath 18 AWG yellow green line i i S Dip soldering irs Protection d 30 7 0 5 3 Note If the KEIN1005S needs to do an insulated withstand voltage test please disconnect the 18 AWG line to disable surge protection circuit which will cause the failure of this experiment w E CHI PORE 3 Disconnect 18 AWG yellow green line 15 6 LED Indicators KIEN1005S User s Manual 201110 KIEN1005S LED indicators Power LEDs 100M fiber port LED ON Effective network connection in the port LINK ACT Blinking Network activities in the port OFF Ethernet RJ45 port LEDs OFF o No effective network connection in the port POE ON POEportsupplies power normally Blinking POE port supplies power abnormally Yellow ex OFF POE port does not supply power ON Effective network connection in the port Link Act Blinking Network activities in the port Green l OFF 7 Product Models OFF No effective network connection in the port The specific configuration models of KIEN1005S are shown in below table KIEN1005S Configuration Table KIEN1005S 1T 4T 4P KIEN1005S 1S M 4T 4P 1 10 100Base TX RJ45 port and 4 10 100Base TX POE ports 1 100Base FX SM MM
9. wer supply mode POE power supply can be achieved in two ways one is power is supplied to PD Powered Device over data wires and secondly the power is supplied to PD over unused wires The specific power supply mode of PSE Power sourcing equipment is automatically matched according to the power receiving mode of PD RJ45 connector of POE port and pin number Pin distribution of 10 100Base TX Pn MDI X signal name MDI signal name POE power supply 1 Receivingdata RD Outputdatas CTD ve se Receiving data RD Output data TD 3 Outputdatar TD Receiving datae RD 11 KIEN1005S User s Manual 201110 Output data TD Receiving data RD V 4 5 7 8 Unused wa n Note means cable polarity Pindistribution of POE power supply over unused wires Pin POE power supply 1 Unused 2 Unused 3 Unused Unused 1 V 5 V 7 y V wa n Note means cable polarity 100Base FX Fiber Ports Fiber port parameters 100M FX Parameter Table Property FX FC SC ST Multimode Single mode Single mode Single mode Single mode ype M 5 5 5 5 Center wavelength nm 1310 1310 1310 1550 1550 Transmission distance Km joa os ow 40 Application range Km 0 40 12 Transmitting Minimum 19 optical dBm 12 KIEN1005S User s Manual 201110 Overload optical power dBm 100M fiber p