Home

TE Product Brochure v1b

image

Contents

1. 0 re 5 0 10 1 10 to 120kQ Residual Resistance 2 000 000 cc cece tteeetteeeseeetteeenes Less than 20mOQ Power Rating 2 2 00 e cette ete 10 watt per resistor Voltage Rating Maximum 500V DC AC RMS Temperature Coefficient 000000 cece eect teeettteeeenneen 200ppm C Dimensions Weight 00 000 w390 x H80 x D150mm 2kg Features ees Ventilated robust metal case and multi wafer switches for low switch contact resistance 1070 5 Decade Capacitance Box 1071 7 Decade Capacitance Box 1070 Range Resolution 2 0 0 0 O to 10uF 100pF steps 1070 Residual Capacitance cece ces Less than 38pF 1071 Range Resolution 2 0 0 0 O to 100uUF 10pF steps 1071 Residual Capacitance ccc Less than SOpF 7A 816 U 2 6 eee eee 1 5 above 10uF 1071 Voltage Rating 0 Maximum 300V DC 200V AC Dimensions Weight w215 x H100 x D120mm 1kg incl protective boot Features cece cece ceee ce cetne eens Bi polar working colour coded digits safety terminals and protective rubber boot 1053 4 Decade Inductance Box Range Resolution 2 0000 cece ete O to 10H 1mH steps Accuracy at 1KHZ e cee tttee ene 3 of setting Voltage TANI rn Maximum 30V AC Maximum Current 00000 e eect ev butts cvtttectteestieeetteen 150mA Residual Resistance 000000 c cece tcetteeteeen Less than 0 2Q Residual Inductance ccc citseeeesestteeeeseenetees Less than 1uH Dimensions W
2. Serial No 89598 Cal Due 27 April 2010 FasyCal Add Ons and Accessories Optional enhancements and extras for increased functionality EasyAdmin EasyAdmin is an add on that provides increased security for EasyCal and it s users User Rights A master user sets the user rights for the relative staff and defines log in criteria Access Levels Setting access levels within EasyCal to limit Secondary users can be done safe guarding sensitive information Administration EasyAdmin provides an administration point for calibration instruments certificate information and user fields Predefined Pick Up Lists For instrument manufacturers sub contractors customer details and other information These can be created to make EasyCal data entry quick easy and uniformed WebCerts WebCerts is a web based application that enables EasyCal users to upload and retrieve certificates and reports online Simple Upload Download Uploading is incorporated into EasyCal by allowing the user to quickly and directly upload to their WebCert folders via FTP Secure User Log In A security feature that allows users to access private folders with their relevant documentation Ideal for companies with different sites or locations Search and Filter Users can easily locate required data by using the filter tabs or the straightforward search fields Hosted Package Time Electronics also offer a hosted
3. layout to determine if formatting is correct Conversion Tables Conversion tables for thermocouples RTDs current transformers and clamp meter adaptors are included a Tent Time Calibrator 9925 Proc T OMMIIN0 Alternatively user defined tables can be created yi Mamae OC Range eers en eimie eom P Manwea Remote Commands ee eae Sa r GFID Commands z For more complex instrument control commands can Eare Tesi be sent on a test by test basis or run as a script Closed prs loop calibration is also achievable using the universal niaka iasa aa or Seg anor oma readback feature This allows EasyCal to control third r EN party calibration equipment and communicate with ae omens Commands Wied hhe to god armer devices under test cs functors 1 yoot camanan Procedure Writing and Editing 28 FasyCal Calibration Software Overview of applications and features Instrument and Device Calibration Automated calibration run provides fast and accurate collection of data whether using direct instrument control or manual entry EasyCal guides the operator CONNECT AS SHOWN SELECT 300 0 RANGE ON through the procedure using graphical test screens and TER iii user prompts Search Selection of the device under test is quick and easy With the use of a barcode scanner this selection becomes automatic Calibration Prompts Text and graphical prompts aid the user with instrument range selection and co
4. internal 1010 DC Voltage Calibrator 0 02 Accuracy C151 1017 DC Multifunction V I R Calibrator 0 005 Accuracy C152 internal opt 9529 1049 PT100 Simulator Handheld Class A C C161 1050 PT100 Simulator Handheld Class A F C161 7005 Voltage Current Loop Calibrator 0 01 Accuracy C184 Electrical Test Calibrators opt 9027 opt 9021 internal opt 1031 lt S opt 7643 opt 7643 opt 9027 opt 9529 internal internal opt 7633 internal opt 7633 field case internal 5068 C189 e e ene 5069 C180 ci12 ieldcase internal 5070 Micro Ohmmeter and Ductor Tester Calibrator C146 C107 field case 5080 C188 aa field case internal Portable Pressure Instruments 7010 C178 C190 field case internal ECFLA 7015 C178 C190 field case internal ECFLA 7016 C178 cio fieldcase internal EOFLA 7018 C178 C190 field case internal ECFLA 7090 Handheld Pneumatic Pump Kit 950mbar to 40bar 7095 Handheld Hydraulic Pump Kit 0 to 700bar with hoses fittings case 2 7089 91 94 96 Digital Gauges 7089 vac only 7091 vac 40b 7094 100b 7096 700b 0 2 acc C202 C203 opt 9804 opt 9805 ECFLA Pressure Range Codes for 7010 7015 7016 7018 and 7030 N a 7108 7109 7110 7107 35 Option Code 7111 7100 7101 7102 7103 7104 7105 7106 33 Product Listings www timeelectronics com tion UKAS Calibration Certificate libra NPL Digital Multimeters 10 Ch Scanner card
5. Hg kPa inHg inH 0 Kg cm mmHg mbar e High accuracy silicone piezo resistive Sensors e Reads both gauge and absolute pressure e Easy to read colour display with full 2 line alphanumerics e Compact and robust with protective rubber housing e H165 xX W115 x Dd5mm weight 0 88kg 9 Pressure Calibration Instruments www timeelectronics com 7030 Automatic Pressure Calibrator A high speed pressure controller calibrator suitable for wide workload calibration of pressure devices such as transmitters sensors and gauges Models can be configured for ranges from 1 to 100bar with a barometric reference option also available e Ranges from vacuum to 0 2 2 5 10 20 35 70 or 100bar e Pressure vacuum calibration 0 025 full scale accuracy e Control speed lt 3 seconds e Control stability 0 004 full scale e Precision 0 015 full scale e Colour touch screen user interface e EasyCal software compatible e Barometric reference option e H191 x W259 x D310mm including handle weight 7 1kg 7010 Single Channel Pressure Calibrator 7015 Dual Channel Pressure Calibrator Portable battery or mains powered pressure calibrators designed for both lab and field applications Models available from vacuum to 600bar 8700psi e Vacuum 0 2 2 5 10 20 35 70 100 200 400 or GOObar versions e Best accuracy 0 04 of full scale e Pneumatic or hydraulic e 4 selectable pressure units 4 per channel on 7015 and mA e Loop curren
6. Lagaut Customer SGE LTD Return te Customer List To reduce the number of certificates listed enter one or more search eitera below Call Date Serial Mo Cartificate No Month Teor lary an Seaech Click Certificate Number to Display Cert Num Instro CalDate InstType Manulacturer Model Mum Serial Num Location Cal Interval Ovner Cal Due Date ooa _fwee7es_fav aw aoo7 oscacegox_friwe__ hos1_fvees3_lpap_ s2_lsos uro asyanraoos_ di iE eani ane feb ft et oa pees wos fwserse a 11 2007 PREQuENCY GeneRaTOR akerectston so03 1585204 Rao 52 53e LTO 26 11 2008 hoon e rasp rucno cuana rorooama femos aerar pao o aaa ai weers 27 11 2007 a 9 a a oe T T oo13__ wse7es _ ze aa 2007 mucTimeren___ vonocawa 73303 asoos4o 52s LTD 26 11 2008 poora wsers2 _fea a aoa7 erequencr aenenaron ew precisionfaoos asas204 ean s2 soe urofae su 2008 ons wse777 ze ny2007 mucn FUNCTION caLiarAaror voxocawa cnoo 12w730730 fao s2 ece cvo 26 a1 2008 20021 sv7a399 awi u2007lorerra pressure meicaronjonuck _owteoaiis xszaree a2 s2 ese evolarvau a0ce 10023 Josoaio7ss ooviuzoorfmucnmeren faeremman arom osoauorss sz see cvo ze a1 2008 00 0 sv74301 _ oa sz aoor orcrras paessure mercaToRjonucx _loetrosiis r4sojo0 0 nao s2 sce evolow aaya0os cos wserss oavszvaoor murimeren aue frm esaiooso aap sz sce erolozvaa cooe Calibration Label CertNo 10051 EasyCal
7. headquarters is based in Tonbridge Kent in the United Kingdom situated 30 miles south of London and occupies 10 000 sq ft of factory and office space Time Electronics also has regional offices in New York USA Dubai UAE Kuala Lumpur Malaysia and Moscow Russia Medica Company Details Time Electronics Limited Unit 11 Sovereign Way Tonbridge Kent TN9 1RH United Kingdom Tel 44 0 1732 355993 Fax 44 0 1732 770312 E mail mail timeelectronics co uk Website www timeelectronics com During our 46 years of continuous development we have built strong business relationships and a wealth of engineering experience We have a global distribution network and are represented by companies with strong technical work staffs and highly skilled engineers Quality is an integral part of our company philosophy In addition to building accurate and durable products we provide extensive customer support This has given us a valuable reputation with organisations worldwide and is one reason for our continued success in the trading market Time Electronics is accredited to ISO 9001 2008 SO 9001 Registered Firm International Accreditation Board Cenificate No 682002725 Registration No 044 Introduction Decade Boxes Resistance Capacitance and Inductance 1051 8 Decade Low Ohm Resistance Box Range Resolution 0 000 teen 0 to 1MQ 0 010 steps Decade 0 010 0 10 10 100 1000 1KQ
8. or touch screen EasyCal Software Enables automatic calibration to increase speed and efficiency of work EasyCal has features to manage and administrate both inventory and quality control Io complement the system a printer and connectivity kit is supplied as standard for generation of certificates and reports Communication Using EasyCal the operator can read back from compatible electrical temperature pressure and loop modules within the bench Furthermore the software can be used with external instruments such as dry block calibrators and portable test instruments 7051Plus Package A comprehensive package including specific options to cover the calibration requirements for electrical and process applications As a package it incorporates the full internal capabilities of the 7051 and is complemented by external adaptors for increased functionality Calibration Benches External Options Pneumatic and hydraulic calibration pumps pressure gauges dead weight testers dry block calibrators pressure test kits hoses and connectors test lead sets solder stations vices and much more Bench Fittings Various fittings can be added to CalBench to improve usability and create a more efficient and organised workspace Under worktop drawers cabinets and CPU holders tool holders and hooks for the perforated back panel air preparation kits desktop mountable devices and more Laboratory Design and Supply Time Electronics of
9. 10 Ch Scanner card RTD Probe Adaptor Factory Cali Certificate Carry Case Rack Mount Kit GPIB Interface 9713 9728 9714 9726 9715 9717 O 4 N oo O N O 5065 6 5 Digit Bench Multimeter ECFLA EasyCal Software oO oO C162 C1 5075 Precision Digital Multimeter O h O O O om pe D 5077 Power Calibrator A Sic E S _ s gt 5 OE sS 2 5 22 o fon re Q gt 2 o ya Se 20 o olo N 5 eI On 2e oe ae 53150 lt lt ie T sles S5ile Slon gr nel s2 le 2 52 5 aeg 5 gt 58 82 4 E E E E 5 Selse s s 2 lzg EE 7ElS Sl NSE o e ES SIOR oj wg To Sle sl 2a e lo 8ist s Nol sc 2a Selang 2 lt 8 ejag ogjis lt Q O rs5 O ag xe s Os 2s Slox I LTOlLT Slax t reel og alto eo2lorlo Oo I ton fare ATE Bench Calibrators CEILS S 8 S Be SS SSl eSleal alc 2 fe es es eelesciea SolsSo0 Soe Polowus SclSe SX Sols SISELSO Sa 5H 50 50 5011 Resistance Temperature Calibrator C171 C115 fo o o Jo 5018 DC AC Voltage Current Calibrator C142 C104 Pele ea 5045 Oscilloscope Calibrator C147 C128 Lo lolol E o ie A 3 a SI O ACG O 2 O c 5 D e e c o 2 258 Slez QE 2 E o 2 losluoa Sto OOleo DE E L a alzo l DA oa z o NOlops ESIS as o s x wa j oa al ols 2 D az en o 2 o0o eo SI g o1 Oc 2alectiec oe 2 D eE EA oOolsg lsze 2fJ c l 2eS gt
10. 10kQ 100KQ Accuracy 10 5 1 0 5 0 1 0 1 0 1 01 Max Current 1A 1A 1A 0 3A 0 1A 33mA 10mA 3mA Residual Resistance Less than 90mO Power Rating 2 2000 e bb tteeee sete 1 watt per resistor Voltage Rating Maximum 250V DC AC RMS Temperature Coefficient 00000 e cece ttteeetttetereteerenes 50ppm C Dimensions Weight w215 x H100 x D120mm 1kg incl protective boot Features Colour coded digits safety terminals and protective rubber boot 1040 8 Decade Wide Range Resistance Box Range Resolution 0 0000 O to 100MQ 10 steps Deae 19 100 1000 o io 100K imo tomo Accuracy 1 0 5 0 1 0 1 0 1 0 1 0 1 1 7 Max Current 0 5A 0 3A 100mA 30mA 3mA 0 3mA 304A 3u Residual Resistance Less than 250mQ Power Rating 2 20 0 te bbc teeeetenee 1 watt per resistor Voltage Rating Maximum 250V DC AC RMS Temperature Coefficient 0000 ectteettteerttteerenes 50ppm C Dimensions Weight w215 x H100 x D120mm 1kg incl protective boot Features Colour coded digits safety terminals and protective rubber boot 1041 5 Decade Low Ohm Resistance Box Range Resolution 0 0000 O to 1kKQ 0 01Q steps Decade 0 010 0 10 10 100 1000 d Accuracy 10 5 1 0 5 0 1 K Max Current 1A 1A 1A 0 3A 01A Residual Resistance Less than 60mO Power Rating 2 20 0 ebbtteeeetenee 1 watt per resistor Voltage Rating Maximu
11. Accessories Primary Licenses ECFL EasyCal Full License stand alone when purchased individually ECFLA EasyCal Full License when purchased with compatible calibrator DMM Extra User Licenses EC2FL EasyCal Additional Full License Secondary user EC2WL EasyCal Work Station License full management scheduling no calibration run EasyCal Add Ons EAD2 EasyAdmin 2 Users Security add on that enables setting of user rights and access levels For installations of 2 users or less EAD5 EasyAdmin 5 Users Security add on that enables setting of user rights and access levels For installations of 5 users or less EAD10 EasyAdmin 10 Users Security add on that enables setting of user rights and access levels For installations of 10 users or less EAD10 Additional users of EasyAdmin beyond 10 users EWC WebCerts Online application enabling upload and retrieval of certificates and reports EWCTE WebCerts Hosted by Time Electronics Online application enabling upload and retrieval of certificates and reports CREP Crystal Reports Sofware Edit and format certificate styles EasyCal Accessories 9795 Printer and Connectivity Kit 9777 Bar Code Reader 9778 Cal and ID Label Printer 9779 Job and Address Label Printer For full listings on calibration benches and options please visit www timeelectronics com Product Listings 34 Time Electronics Calibration Test and Measurement Time Electronics Ltd
12. Current Calibrator A portable benchtop DC current source for calibration and test applications from nanoamp levels to 100mA Applications include current transducer testing and calibration and linearity tests on digital and electronic current meters e 0 to100mA output in 5 ranges e Safety terminals e Accuracy 0 02 of setting e Battery or mains operation e 10ppm hr stability e 12 hours typical use between charges 30ppm C temperature coefficient e Battery level indicator e Up to 15V output drive e Optional carry case e Null meter measures to 14A resolution e W217 x H160 x D1938mm weight 3 3kg 1021 Milliamp Source with Null Indicator A precision DC current source suitable for calibration and test applications from micro amp levels up to 100mA The 1021 is used to calibrate current sensitive transducers and their associated indicating and recording instruments e 0 to 100mA output in 3 ranges e Safety terminals e Accuracy 0 02 of setting 0 02 of rng Removable protective boot e 25ppm hr stability e 10 hours typical use between charges e Up to 40V output drive e Battery charger supplied e LED null measuring facility e Optional carry case e Short circuit overload protected e H215 x W100 x D120mm weight 1 4kg 5 Voltage and Current Test Equipment 1077 Milliamp Transducer Simulator A multi purpose handheld test instrument that can be used as an adjustable current load adjustable power supply or precision current sourc
13. Unit 11 Sovereign Way Botany Industrial Estate Tonbridge Kent TN9 1RH United Kingdom I 44 0 17382 355993 F 44 0 1732 770312 E mail timeelectronics co uk www timeelectronics com For more information please contact your local Time Electronics representative Due to continuous development Time Electronics reserves the right to change specifications without prior notice
14. WebCerts package where data is uploaded and stored on one of our designated WebCert servers Retrieval and viewing of certificates is via the web based interface EasyCal Accessories To complement and further optimise the calibration process Time Electronics offer a range of external options Printer and Connectivity Kit Inkjet printer for calibration certificates and reports Also includes a DVD RW 4 port USB hub numeric key pad and USB memory stick Calibration and ID Label Printer For printing labels to be placed on calibrated units EasyCal has different layouts for required information to be shown Job and Address Label Printer For printing information that accompanies a unit under test through the calibration process Also for user tagging instruments Bar Code Reader Enables fast identification of devices in the pre calibration stage EasyCal to PC Communication Options Interface cables and adaptors providing PC connectivity to Time Electronics calibrators or external instruments 31 EasyCal Add Ons and Accessories FasyCal Networking With networking capabilities a multi user system can be implemented Networking with EasyCal For multi user systems EasyCal can be implemented as the universal software for administration management and control With designated features for use in different workstations EasyCal can provide a solution to calibration businesses with customers as well calibration departments within
15. e Battery level indicator e Accuracy 0 1 of range e Battery powered 9V PP3 e Linearity 0 15 e 60 hours typical battery life e Up to 8V output using 1kQ resistor e Supplied with carry case e Precision 10 turn dial e H115 x W62 x D55mm weight 0 24kg 1044 Voltage Current Calibrator A precision handheld calibrator that can be used as a general purpose current and voltage source High performance and ease of use make it suitable for test engineers R amp D service and calibration technicians e Measure voltage and current e Battery powered 9V PP3 e Source voltage and current e 28 hours typical battery life e 3 voltage ranges 0 to 20V e Optional mains power supply e 3 current ranges 0 to 20mA e Supplied with carry case e Accuracy 0 05 of range e H142 x w78 x D5O0mm weight 0 30kg e 4 5 digit LCD display e Voltage Current Loop version 1048 Voltage and Current Test Equipment 6 Loop amp Temperature Calibration Instruments Handheld Loop Calibrators RTD and Thermocouple Calibrators 1048 Voltage Current Loop Calibrator A compact voltage current and process loop calibrator for engineering manufacturing test and process control applications The 1048 combines digital accuracy with simple analogue control and is well suited to plant operations such as powering control loops e Source measure voltage and current e 3 source ranges 0 to 22mA and 0 to 22V e 3 measure ranges 0 to 70mA and O to 50V e Accuracy 0 02 of r
16. e Continuous connection no arcing e Fully shrouded safety connectors e Display of open circuit voltage 0 to 2kV or 0 to 9kV e Display of short circuit current 0 to 2mA or 0 to 20mA e W406 x H175 x D330mm weight 4 4kg 5070 Ductor Tester Micro Ohmmeter Calibrator The DuctorCal is a portable instrument suitable for calibrating high current ductor testers and micro ohmmeters It contains 5 sets of high current rating standard resistors that simulate the resistance being measured e Calibrate ductor testers and micro ohmmeters e 0 2 2 20 200 2000mMQ ranges e Accuracy rng 0 2mO 0 8 2MO 0 5 2OMQ 0 2 200 amp 2000MQ 0 1 e 5 point calibration 0 25 50 75 100 e Gold plated terminals e Low thermal EMF connection e Portable robust carrying case e W540 x H210 x D410mm weight 11kg 5080 Portable Appliance Tester Calibrator Designed to provide rapid high accuracy calibration of portable appliance testers and insulation continuity testers The 5080 has calibration functions for earth bond insulation leakage touch leakage and load test e Earth bond range 18Q to 20mQ e Earth bond currents up to 50A AC e Load test currents up to 13A AC e Accuracy Resistance 1 of setting Voltage and Current to 0 25 of reading e Voltage and current displayed on integral LCD display e Safety interlock feature e Portable robust carrying case e Battery powered over 200 hours between charges e W406 x H175 x D330m
17. industrial plants Data can be shared and accessed on a central server creating an organised and efficient networking set up EasyCal s pre calibration features enable automated scheduling and also speed up the booking in process with quick instrument identification Calibration runs can be automated by using a compatible Time Electronics calibrator with EasyCal Once calibration has been performed the data can be made available on the server to the necessary parties Hard copy certificates and reports can be issued by authorised staff Enhanced security features can be added for increased protection allowing a master user to control access rights to data and applications Also available is an online application enabling users to upload and retrieve certificates Calibration Lab Calibration and verification is performed BE using a 5025 multifunction calibrator or similar unit Goods In EasyCal can be used to automate the calibration process create or edit test scheduling is simplified by EasyCal s recall reminder system Instruments are returned following reminder letters emails Instruments arrive and are booked in Job sheets and labels can be produced EasyCal starts to optimize the job process for fast turnaround time __ A simple search feature can locate the gl instrument s data or a barcode reader can instantly identify the item Once uploaded on the system necessary parties can access modify data
18. make the 5065 an ideal DMM for a variety of applications With a comprehensive range of features the 5065 is suitable for test engineers R amp D service and calibration technicians e 6 2 digit resolution e Accuracy 0 005 DC voltage e RS 232 and USB interfaces e Optional GPIB interface e Temperature measurements e SCPI command set e High sample rate e 10 channel scanner card option e PC laptop control via EasyCal software e W210 x H85 x D350mm weight 4 4kg 5075 Precision Digital Multimeter A benchtop digital multimeter that combines high performance with simple operation The 5075 easily measures from nanovolts to 10kV from picoamps to 30 amps from micro ohms up to 1GQ from picofarads to 300uF with up to 7 digit accuracy e 7 digit resolution e 10nV to 10kV 10pA to 30A e Resistance capacitance frequency e 18ppm accuracy best 1 year e 10 channel low thermal emf scanner option e PC laptop control via EasyCal software e GPIB interface USB adaptor available e Rack mount kit option e W423 x H89 x D415mm weight 8 5kg ATE Bench Calibrators and Digital Multimeters 18 About CalBench CalBench is the ultimate multifunction calibration station from Time Electronics Each bench is custom made to meet specific user requirements Offering versatility and precision it is ideal for laboratories and workshops in need of multi product testing that meets the highest industry standards A wide range of modu
19. module e Customer specific modules e Modules from Time Electronics portable and benchtop instruments range e Additional sockets fittings and connections on modules e Optional secondary console shelf unit 7081S Supporting Instruments and Extras In addition to bench modules a selection of instruments and accessories can be provided to complement the system and enhance functionality e Pressure Handheld and tabletop pumps gauges and dead weight testers e Process Field calibrators dry block calibrators and flow controllers e Dimensional and Mass Gauge block sets 7151 shown and test weight kits e Line pressure Compressors vacuum pumps air amplifiers and gas boosters e Repair amp maintenance Solder stations worktop vices magnifyers and more e Multi purpose Electronics service cases and tool kits e ESD Anti static worktops grounding products wrist wraps and more e Lab Furniture Accompanying work benches cabinets trollies See page 23 e Bench fittings Under worktop drawers back panel tool kits and holders Calibration Bench Modules and Extras 22 The Design Process Time Electronics offer a turnkey design and supply service for customers requiring an efficient and ergonomic on site calibration laboratory It is created virtually then supplied complete including all specified test instruments tools and furniture CalBench acts as the primary work station of the laboratory and is used fo
20. operation portable loop signal indicator with LCD display Suitable for use with the 7006 Loop Mate 1 e 4 to 20mA O to 10V O to 50V ranges e LCD 4 digit display mA V or of range e Accuracy 0 05 of reading e RxSim TxTest or 50mA 50V measure modes e Internal loop supply 25mA maximum e Battery powered 9V PPS 40 hours typical use e Supplied with carry case e H140 x W65 x D3Omm weight 0 20kg 7 Loop and Temperature Calibration Instruments www timeelectronics com 1049 PT100 Simulator A handheld precision simulator for PT100 0 3850 platinum resistance elements used for accurate temperature measurement High performance metal film resistors are used throughout which ensures a good temperature coefficient and long term stability e 200 C to 800 C with 23 set points e Accuracy 0 3 C e Less than 30ppm C temperature coefficient e ITS 90 IEC60751 e Exceeds class A e Passive resistance source e Supplied with carry case e H112 x W61 x D55mm weight 0 17kg e F version available 1050 100 F to 1000 F 0 5 F accuracy 7000 RTD Temperature Calibrator A portable process control instrument that combines a precision digital thermometer using RTD probes with an RTD ohms calibrator e Temperature Accuracy 0 05 C 0 09 F Resolution 0 01 C 0 02 F e Resistance Accuracy 0 03Q Resolution 0 01Q e 2 3 and 4 wire connections e Measure and simulate C F K and ohms e Ramp and s
21. resistance e Thermocouple simulation e Digital frequency e Oscilloscope calibration e PT100 simulation e Capacitance and inductance e Power calibration e Clamp meter calibration e GPIB RS 232 USB Interfaces Multi Instrument Calibration The 5025 series are high performance multi product calibrators that provide the foundation for cost effective calibration Built for versatility and simplicity each model offers a solution to efficient calibration of a wide range of test and measurement equipment Each model features AC DC voltage and current digital frequency decade and simulated resistance capacitance conductance PT100 and thermocouple simulation Options include power and oscilloscope calibration and enhanced performance packs that provide full range variable resistance extended capacitance inductance and increased ACV frequency bandwidth External adaptors are available for clamp meter calibration optical tachometer calibration and more PC Virtual Control Simple Operation Functions and ranges are easily accessed from the front panel Increase and decrease keys per digit are used to quickly set the output value Deviation control then enables the user to finely adjust the output value as a percentage 9 999 All this information is shown on a clear easy to read LED display Calibration Made Easy Connect the 5025E or 5025C to a PC Laptop installed with Time Electronics EasyCal software and
22. values decade steps 270 to 1820 C type J K R T S B E N 180 to 850 C 20ppm of setting 100ppm of setting 20ppm of setting 0 15 C ae 007G 0 05 6mV to 200V and 6mV to 2V 500 Square wave or DC 0 1ppm 0 1Hz to 10MHz 100ns to 10s 20ppm 20 50 1OOMHz 50 20 amp 10ns 3 frequencies 100Hz 1KHz 10KHz settable from O to 100 lt 400ps Bandwidth checking up to 400MHz 100MHZz to 2 2GHz levelled sine wave 0 5 1 1 5V pk pk 0 1Hz to 100OMHz 10ns to 10s fixed values 1 2 5 sequence Amplitude 1 Frequency 20ppm 6 5 Digit Multimeter measure Voltage DC Current DC Voltage AC Current AC Resistance Frequency Thermocouple PT100 PC Specifications Details Processor RAM Hard Drive Ports Display Operating System Included Software Programs Supplied Hardware Accessories Options Oscilloscope Calibration Options External Adaptors Instruments EasyCal Software Accessories and Calibration Certificates General Specifications Supplied Items Warm up Settling Time Temperature Performance Operating Humidity Altitude Line Power Dimensions Weight Supplied Test Lead Set 64 bit dual core or equivalent AGB or higher 60 GB Solid State or higher 4 x USB 1 x Fast Ethernet 10 4 Touch Screen LCD Windows 8 1 Calibrator and DMM control programs EasyCal calibration software suite USB keyboard Inkjet Printer Cal and ID Label Printer DV
23. without the need for paperwork to be passed from station to station CENTRAL Calibration Manager Can oversee the complete operation The calibration standards and instruments used by the laboratory are also monitored on the system Create edit and sign off test procedures Certificates can be created issued and signed off as required PDF copies can be held on the server for web upload or email purposes procedures and enter in any ongoing job information With the networking system in place the process of performing site calibrations is made faster and easier The required information for a site job i is transferred to a laptop or 5051 calibration system Calibrated labels can be printed and placed C on instruments before leaving the lab Alternatively calibration test forms can be produced for hand written entry servers database or entered into The data is imported to the central EasyCal back at base manually SERVER Online Customers or employees can use EasyCal s WebCerts a web based application allowing certificate retrieval online A secure log in feature allows access a the user s private folder with their relevant documentation View and issue reports and certificates Simulate calibration runs Create and update uncertainty information Monitor progress and calibration statistics As the key user the manager can control user access t
24. 7 AlE Bench Calibrators and Digital Multimeters Programmable Calibrators and Benchtop DMMs pu m E Sa e 5011 Resistance Temperature Calibrator A versatile high accuracy calibrator that is primarily a programmable resistance RTD source Internal options such as DC voltage and thermocouple simulation DC current and 10MHz frequency can be added to increase capabilities e 10 to 120MQ 100ppm basic accuracy e RTD simulation e Optional thermocouple simulation e 0 to 22V DC voltage option e 0 to 220mA DC current option e 10MHz frequency option e RS 232 GPIB and USB interfaces e Front panel operation e PC laptop control via EasyCal software e Rack mount kit option e W451 x H152 x D272mm weight 7kg 5018 Programmable DC AC V I Calibrator A high precision calibration instrument that can be configured as a simple benchtop DC voltage calibrator or advanced AC DC voltage and current source controlled via PC performing any number of tasks as part of a complex ATE test rig e 15ppm accuracy 0 5ppm resolution e 1999999 full scale 10 over range e 20mV 200mV 2V 20V DC voltage e Deviation control 9 999 to 9 999 e Ramping feature e RS 232 GPIB and USB interfaces e Ideal for ATE applications e Front panel operation e PC laptop control via EasyCal software e Rack mount kit option e W451 x H152 x D272mm weight 8 2kg 5045 Oscilloscope and Timer Counter Calibrator A high performance benchtop i
25. D RW 4 port USB hub Numeric key pad USB memory stick 9769 Internal Scope 2 2GHz Levelled Sine Generator 9762 External Rubidium Frequency Reference 9764 Current Probe Adaptor 9773 Optical Tacho Adaptor 9790 100 Amp AC Current Transformer 9760 Power Amplifier 60V AC 90V DC 100mA TEG Digital Pressure Gauges with RS 232 e 7085P Temperature Distribution Unit e 7070 7071 7072 Dry Block Calibrators 9777 Bar Code Reader 9779 Job and Address Label Printer e EC2FL EC2WL Additional User Licenses for separate PCs EAD EasyAdmin Add On EWC WebCerts Add On CREP Crystal Reports Software e C134 UKAS Calibration Certificate 5051PLUS Calibration System Clamp Meter Adaptor Premium Test lead Set Soft Carry Case e Printer and Connectivity Kit Cal and ID Label Printer 5051 Manual Control Software e EasyCal Calibration Software e Factory Calibration Certificate NPL 30 minutes to full accuracy Less than 5 seconds Operating 5 to 45 C Calibration 15 to 28 C Storage 10 to 50 C lt 80 non condensing Altitude 0 to 3km Non operating 3km to 12km 100 to 260V AC 50 60HZz 220W maximum w430mm H202mm D538mm Weight 23kg High voltage pair High current pair Low thermal pair Shielded 4 wire BNC test lead BNC thermocouple spade adaptors Test clips couplers pair Wall mount lead holder Carry case 9051 Plus Multifunction Calibration System 16 AR Aso LD PC Virtual Control 1
26. E Time Electronics Calibration lest and Measurement Product Brochure A www timeelectronics com Conients Decade Boxes Resistance capacitance and inductance Portable Voltage and Current Test Equipment Handheld and transportable calibrators simulators and sources Portable Loop and Temperature Calibration Instruments Handheld loop calibrators RTD and thermocouple calibrators Pressure Calibration Instruments Calibration pumps pressure calibrators and digital gauges Electrical Test Calibrators Instruments for rapid calibration of electrical test equipment Multifunction Calibrators 5025E 5025C and 5051 Precision calibrators for wide workload coverage ATE Bench Calibrators and Digital Multimeters Programmable calibrators and benchtop DMMs Calibration Benches Comprehensive modular test benches and complete laboratory design Calibration Software For laboratory office and site calibration work Product Listings Complete listings of products ANd Options EE Ean 1 Contents e Introduction About Time Electronics Established in 1967 Time Electronics Ltd is an international company that designs and manufactures calibration and metrology instrumentation We have a comprehensive range of test equipment for use in applications across various industries Products include decade boxes portable and benchtop calibrators DMMs and custom made test benches Time Electronics
27. Each module offers high accuracy and excellent resolution e 7027 7027A 3GHz 6GHZ universal frequency counter e 7028 10MHz DDS function generator e 7029 25MHz function arbitrary pulse generator e 7031 50MHz function arbitrary pulse generator e 8023 1OMHz DDS function generator with sweep and 120MHz counter e 8026 8027 12MHz 25MHz DDS function generator with counter e 7048 2GHz synthesised signal generator AM FM phase modulation e 7058 6GHz signal generator Oscilloscope Modules Oscilloscope modules with standard features including USB connectivity automated measurements limit testing data logging and context sensitive help e 5 7 LCD colour display e Autoset and signal auto ranging e External trigger output e Probe check wizard Bandwidth Sample Rate Ch Record Length 100MHz 4 20G8 s 2 5k points 200MHz 4 20GS s 2 5k points s00MHz 4 5 0GS s 10k points Additional and Custom Design Modules CalBench is fully customisable and Time Electronics can fit Customer specific modules or extras Users can request instruments and devices be fitted in the bench consoles modifications and additions to our Current modules or bench and console modifications e CC10 amp CC12 Control centre modules with integral PC amp touch screen e 9758B DC electronic load module for power supply calibration e 7034 and 7035 soldering and rework modules e 7063 Isolated mains output sockets for 7082 mains power
28. EasyCal optimises the process by allowing the user to create procedures quickly and easily with the help of the included design wizards and pre written templates Post Calibration Easily produce calibration certificates and reports to ISO 9001 ISO 17025 and other quality standards These can be printed stored or emailed as PDFs EasyCal has a selection of preformatted certificate templates suitable for displaying typical calibration results oo The Core Benefits of using EasyCal Achieve compliance with quality standards Create an efficient control and e Automated document control ensures conformity management system and quality e Reduce testing times e Establish procedures to maintain repeatability Eliminate continual outsourcing calibration costs and monitor quality e Full control over the calibration process e Schedule and maintain calibration intervals e Improve turnaround e Evidence of traceability to national standards e Quick and easy solution to instrument analysis e Record calibration environmental conditions when needed e Produce calibration labels maintain calibration history e Internal scheduling for calibrations No external factors e Reduce possibilities for errors or omissions Centralised document management e Electronic record retention ensures integrity On demand networked review of certificates for successful audits and reports EasyCal Calibration Software 26 21 FasyCal Cal
29. Oscilloscope Calibration Amplitude 2mV to 200V and 1mV to 2V 50Q Square wave or DC 0 05 Frequency Period 0 1Hz to 100M Hz 10ns to 10s fixed values 1 2 5 sequence 20ppm Duty Cycle 3 frequencies 100Hz 1kHz 10kHz settable from 0 to 100 Fast Rise lt 400ps Bandwidth checking up to 400MHz Option 9783 Frequency Reference 0 1ppm enhanced accuracy for timer counters Option 9769 2 2GHz Sweep 5OMHZ to 2 2GHz levelled sine wave 0 5 1 1 5V pk pk Amplitude 1 Frequency 20ppm Option 9797 Power Calibration Power 22A 1050V 23kW 45 to 400Hz ACV 0 03 DCV 0 01 ACI 0 1 DCI 0 03 Phase Power Factor 90 0 00 to 1 00PF 0 3 Enhanced Performance Packs 5025E option 9702 5025C option 9701 added values types shown in bold where applicable Full Range Resistance 1Q to 120MQ variable 100ppm of setting RTD Simulation 180 to 850 C Type PT100 PT200 PT500 PT1000 0 03 C Extended Thermocouple Simulation 210 to 2315 C Type J K R T S B E N C L U OOS CG Extended Capacitance 1nF 10nF 20nF 50nF 100nF 200nF 500nF 1uF 10uF 20uF 50uF 100uUF 0 2 of setting 5025E 1mV to 200mV 100kHz 200mV to 2V 100kKHz 2V to 20V 100kHz Extended AC Voltage Frequency 0 05 of setting 5025C 1mV to 20mV 300kKHz 20mV to 200mV 300kHz 200mV to 2V 1MHz Additional Enhancements 5025C only included in option 9701 Enhanced DC High Voltage 20 to 200V and 100 to 1020V additional
30. S 232 USB and GPIB on 5025C Dimensions Weight w455mm H155mm D480mm Weight 16 5kg 5025E and 5025C Multifunction Calibrators 14 Multitunction Calibrators Precision calibration for wide workload coverage 5051 PIUS multitunction Calibration System Integral Calibrator Multimeter and PC e Source up to 1050V AC DC voltage e Source up to 22A AC DC current e Source up to 1GQ resistance Thermocouple simulate and measure e PT100 simulate and measure e Source capacitance and inductance e Oscilloscope calibration e Clamp meter adaptor included e EasyCal calibration software included f 7 Frequency Meters IO I LEE Joia CUAL O TIINAT TOCE O Calibrator DMM Touch Screen PC The 5051 Plus Calibration System combines a high accuracy calibration source with a precision digital multimeter Designed for a wide workload the 5051 calibrates both traditional and new test equipment quickly and accurately The 5051 control software allows the operator to easily select the wide range of functions using mouse keyboard or touch screen Standard internal features include AC DC voltage current resistance frequency thermocouple PT100 simulation and measure capacitance inductance calibration and oscilloscope calibration Also supplied is a clamp meter adaptor for clamp calibration up to 1100A and test lead set to provide the necessary connections for nearly all applications CT ANG PHO Compact Sy
31. al 250V DC 0 375A adjustable power supply Digital Dual adjustable power supply 2 x 30V DC 3A Digital Adjustable AC power supply 0 to 270V 10A 110 above line voltage Variable AC DC power supply AC 1000VA DC 800W Freq 40 500Hz Pressure Modules The Time Electronics range of pressure modules for CalBench include low and high pressure calibrators indicators and line controllers e 7059 Vacuum and pressure calibrator vacuum plus ranges to 10bar 145psi e 7062 Pressure calibrator ranges from vacuum to 20bar 290psi e 7064 High pressure calibrator ranges from 35 to 200bar 2900psi e 7066 Differential pressure calibrator ranges from 0 2 to 10bar 145psi e 7030B Automatic pressure calibrator ranges from vacuum to 100bar 1450psi e 7032 Semi automatic pressure calibrator ranges from 0 2 to 10bar 145psi e 7065 Standard pressure indicator ranges from vacuum to 600bar 8700psi e 7038 Multifunction pressure indicator ranges from vacuum to 600bar 8700psi e 7084 Line pressure controller ranges from 5 to 200bar 2900psi e TE Gauge Pressure Modules Panel mounted precision digital pressure gauges Loop and Temperature Modules For process control applications a range of simulators loop and temperature calibration modules are available The 7051 can also be used as an automatic process calibrator e 7001 e 7068 e 7077 e 7061 e 7085 e 7067 e 7069 e 7079 PT100 simulator C a
32. ange e Transmitter simulator sink loop control e Output steps and ramps e Fine adjustment inching e Battery powered 9V PP3 20 hours typical use e H142 x W78 x D50mm weight 0 34kg 7005 Voltage Current Loop Calibrator A handheld instrument for the calibration and simulation of voltage and current loops The 7005 is a high accuracy compact calibrator with source and measure capabilities e Current measurement 125mA source 50mA Resolution 14A e Voltage measurement 25V source 21V Resolution 1mV e Accuracy Source 0 01 of setting Measure 0 01 of reading e Transmitter and square root functions e Auto ranging feature e Programmable steps and ramp e 9 hours typical use between charges e Supplied with battery charger and carry case e H165 x W90 x D45mm weight 0 42kg 7006 Loop Mate 1 Loop Simulator and Source A cost effective handheld loop simulator that provides 4 to 20mA or O to 10V loop signals Features include manual and automatic step modes with audible indication that changes pitch as the output increases decreases e 4 to 20mA or 0 to 10V ranges e Set points O 10 25 50 75 90 100 of range e Accuracy 0 1 of range e TxSim or RxTest modes e Internal loop supply 25mA maximum e Auto stepping mode up down up 0 5 1 2 4 or 8 sec step e Battery powered 9V PPS 40 hours typical use e Supplied with carry case e H140 x W65 x D3Omm weight 0 18kg 7007 Loop Mate 2 Loop Signal Indicator A simple
33. automate the calibration process Increase speed of calibration and consistency of results produce calibration certificates and reports to industry quality standards 13 5025E and 5025C Multifunction Calibrators www timeelectronics com 5025E and 5025C Specifications Function Range Values Best 1 year Specification 5025E 5025C Voltage DC O to 1050V 40ppm of setting 15ppm of setting Current DC O to 22A 120ppm of setting 60ppm of setting Voltage AC 1ImV to 1050V 20Hz to 20kHz 100KHz on 5025C sine wave 0 04 of setting 200ppm of setting Current AC 10uUA to 22A 20Hz to 1kKHz 5KHz on 5025C sine wave 0 07 of setting 0 05 of setting Thermocouple Simulation 210 to 1820 C Type J K R T S B E N 0 3 C 0 05 C Digital Frequency Period 0 1Hz to 10MHz 100ns to 10s 20ppm of setting 20ppm of setting Conductance 5025E 100ms to ins 5025C 1s to 1ns decade values Decade Resistance 5025E 100 to 1GQ 5025C 10 to 1GQ decade values Simulated Resistance 5025E 400 to 40kQ 5025C 100 to 40MO variable PT100 Simulation 5025E 140 C to 850 C 5025C 180 C to 850 C Orzo 0 15 Capacitance 1nF 10nF 20nF 50nF 100nF 200nF 500nF 1uF 0 25 of setting 0 25 of setting Option 9780 Clamp Meter Adaptor AC DC Current up to 1100A DC 45 to 90Hz 0 5 0 5 60ppm of setting 20ppm of setting 60ppm of setting 20ppm of setting 0 02 of setting 0 02 of setting Option 9770
34. e The 1077 is commonly used for the testing and simulation of milliamp transducer systems e 3 operating modes e Safety terminals e Accuracy 0 02 of setting 0 02 of rng Removable protective boot e 100mA source and load in 3 ranges e 10 hours typical use between charges e 24V line mode e Battery charger supplied e Variable drive source 14 to 40V e Optional carry case e Short circuit and overload protected e H215 x W100 x D120mm weight 1 5kg 1017 Voltage Current Resistance Calibrator A portable multifunction calibrator with voltage current and resistance ranges The 1017 is suitable for calibrating a wide range of instruments including thermocouples transducers transmitters and platinum resistance thermometers e DC Voltage 10nV to 100V e Stability lt 5ppm day lt 25ppm yr e DC Current 100nA to 100mA e Residual resistance lt 200mMQ e Resistance 10mQ to 10kO e Deviation control Voltage and Current e Accuracy 0 005 of setting 0 002 of rng Battery or mains operation e 1ppm setting resolution e 12 hours typical use between charges e Noise lt 2ppm 0 1 to 1Hz e W250 x H119 x D314mm weight 2 4kg 1030 Voltage Current Source A simple operation pocket sized calibrator suitable for voltage and current loop signal simulation as well as thermocouple simulation A cost effective and popular instrument used in various applications across industries e 10mV 100mV 1V ranges e 1kQ resistor supplied e 10mA 100mA ranges
35. eight a w248 x H62 x D102mm 0 8kg Features cn Robust metal case and front panel safety terminals Decade Boxes Voltage and Current Test Equioment Handheld and transportable Calibrators Simulators and Sources 1006 DC Millivolt Source 1007 DC Millivolt Potentiometer and Calibrator High accuracy handheld millivolt sources primarily used for voltage injection or potentiometric voltage measurement 1007 Applications include thermocouple simulation and calibration of A D converters and chart recorders e 3 ranges up to 1V e Safety terminals e Accuracy 0 02 of setting 0 02 of rng Removable protective boot e 20mA output current e Powered by 6 x AA batteries e Best resolution 1uV e 100 hours typical battery life e Short circuit and overload protected e Optional carry case e LED null measuring facility 1007 H215 x W100 x D120mm weight 1 2kg 1010 DC Voltage Calibrator A highly stable and accurate calibrator designed for applications requiring a precision voltage source of low internal resistance Suitable for calibration linearity and gains stability measurements on DC amplifiers voltmeters data loggers and chart recorders e 0 01uV to 10V in 5 ranges e Battery or mains operation e Accuracy 0 02 of setting e 40 hours typical use between charges e 10ppm hr stability e Battery level indicator e 30mA output current e Optional carry case e Safety terminals e W217 x H160 x D193mm weight 3 3kg 1024 DC
36. es enable the user to locate any data on demand Keeping track of instrument history and servicing is made easy Certificate Templates A range of pre formatted templates are available for immediate use A company logo can be added without the need for 3rd party software Electronic Signatures Password protected electronic signatures allow management to approve certificates In addition a scanned image of the signature can automatically be inserted eliminating the need to print certificates Built in PDF Engine Generate PDF reports and certificates ready for emailing and universal review Calibration Reports Documented traceability provides a recorded audit trail Reports showing calibration duration times can assist with costing and assessments Archive The results database can be streamlined by using the archive feature This improves data organisation and management Archives are quickly retrieved giving instant access to historical certificate data Import and Export Exchange data from one system to another using the import export feature This method is ideal for site and field calibration work where data is recorded externally then uploaded to the main database upon return Customise Crystal Reports optional allows full modification of certificate label and report layouts Design custom reports using queries formulas and running totals CERTIFICATE OF CALIBRATION eine hy Terit Si JOLay iih Tima F ip
37. fers a turnkey laboratory design service for Customers requiring a complete and efficient test facility Using 3D software we create the layout then generate images and videos to visualise the concept We supply all the necessary test equipment and surrounding laboratory furniture Features e Integral multifunction calibrator DMM and PC e Source and measure functions Easy to use touch screen Includes EasyCal calibration software AC DC voltage and current Resistance capacitance and inductance Frequency period and duty cycle RTD and Thermocouple simulation measurement HART and Foundation Fieldbus options Built in procedure library for test devices and instruments e Wizards for pressure and temperature devices e Automate calibration jobs e Manage and issue certificates reports and labels 20 Calibration Bench Modules Calibrators power supplies digital multimeters oscilloscopes and more Power Supply Modules CalBench can be fitted with a number of power supply modules depending on user requirements Modules include simple operation fixed DC and AC supplies and precision adjustable supplies e 7083 e 7087 e 7052 e 7053 e 7054 e 7055 e 7056 e 7088 e 7047 Dual 24V DC power supply 2 x 24v 2A Quad DC power supply 6V 20A 12V 10A 24V 6A 48V 3A 30V DC 3A adjustable power supply Digital 56V DC 4A precision adjustable power supply Digital 120V DC 0 75A adjustable power supply Digit
38. ibration Software Overview of applications and features 2 Email Report To PETER DAY Subject RecalibrationDue 2ndReminder Attachment ReminderEmail Report Message Instruments in the attached report are now due for calibration a S 2 Inventory Reminders and Jobs A comprehensive inventory database can be created and customised to company requirements For internal calibration and quality management departments and users can be specified Alternatively EasyCal can be used as the controlling system for a calibration business based around customers and owners Search A powerful search feature enables the user to enter specific criteria to quickly find the required data When adding details the user is aided by drop down lists which automatically update when new information is added Input Fields Used to add details such as ID and serial number manufacturer and model instrument status and service notes In addition custom fields can be created to integrate with a company system Images can be Uploaded to provide further reference Instrument Recall and Reminder System Instruments which are due for calibration are listed on screen Reminder letters and lists can be printed or emailed directly to the customer or department An advanced notice period can be set to bring forward the recall date allowing for response time Job Management When a unit for test is booked in the job process starts Spec
39. icient including line pressure tools such as compressors and vacuum pumps b 1000mm 1200mm B ae Mounting Frame pi THE CALBENCH 1200mm L E O 2000mm N bx g T Trolley v Perfo Wall Storage Cabinet 23 Pas Laboratory Design and Supply On site Bench Installation Training amp Calibration Time Electronics have comprehensive after sales Support packages for customers that purchase calibration benches accompanying test instruments and workshop equipment On site bench and lab installation A travelling engineer will visit the test facility and install and commission the CalBench supporting instruments and laboratory furniture Our technicians can perform site visits worldwide and are qualified to work on offshore platforms power and processing plants and refineries On site training and demonstration Bench training can be included with the lab installation or scheduled for a later date The technician will educate the users on how to set up the system and operate the bench modules and additional test instruments They will also simulate the calibration process by demonstrating tests on actual devices at the site On site annual bench calibration and maintenance service A technician can visit the test facility annually to perform calibration of the CalBench and test equi
40. ific information about the job is entered such as service required sub contracted and accessories supplied A job sheet and label can be produced at this stage to accompany the instrument As the job is put through the system these parameters can be updated for example quote price job status and invoiced Attachments Create links to technical files specifications web pages word documents videos and more These can be set to automatically display prior to the calibration run Devices and Standards used for Calibration Traceability information for instruments and standards that perform the calibration work is stored and maintained by EasyCal Uncertainties Uncertainty tables for laboratory and site can be created for each calibrating instrument These are then automatically processed and applied to certificates as required Inventory Reminders And Jobs A www timeelectronics com Procedure Writing and Editing Creating and editing test procedures is made simple with an intuitive user friendly interface Editing test information can be done by adding inserting or copy Time Electronics calibrating equipment and pasting EasyCal keeps track of each time a Digital Anaiog Multimeters RCL Meters procedure is edited Clamp Meters and Current Sensors Oscilloscopes and Scope Meters Procedure Library A calibration library comprising of over 1200 procedures coveri
41. imulate J K T E R S B N e RTD measure and simulate PT100 e Battery or mains operation e W270 x H175 x D250mm weight 4 5kg Loop and Temperature Calibration Instruments 8 EasyCal iv 4 Vay ow Pressure Calibration Instruments Pressure Calibrators Test Pumps and Digital Gauges 7090 Pneumatic Calibration Pump 7095 Hydraulic Calibration Pump Pneumatic and hydraulic calibration pumps that combine high performance with durability Features include contoured cushioned handles for comfort and dual O rings on all pistons to ensure zero leakage e 7090 Vacuum to 950mbar pneumatic pressure to 40bar 600psi e 7095 Hydraulic pressure to 700bar 10 000psi e Non oil based lubricant used on all moving parts e Both supplied as kits with carry case hoses and fittings e 7090 H200 x w125mm weight 0 91kg e 7095 H240 x w125mm weight 1 4kg e Digital pressure gauges available 7091 and 7096 7193 7194 7195 Benchtop Pressure Calibration Pumps Benchtop pumps that are a comfortable and simple operation providing an easy way to generate pressure in the lab Each pump is a dual pressure source enabling them to be used as comparators for calibration with accompanying reference gauge e 7193 Pneumatic Pump 0 95bar vacuum to 40bar 600psi pressure e 7194 Pneumatic Pump 0 95bar vacuum to 100bar 1500psi pressure e 7195 Hydraulic Pump 0 9bar vacuum to 600bar 8700psi pressure e Easy to
42. itten test procedures included e Calibration due reminder system e E mail reminder letters and lists e Customise reports and certificates e Create PDF reports and certificates PDF engine e Print and read bar codes e Universal instrument control e HART and Foundation Fieldbus communication e Secure user log in and electronic signatures e Create uncertainty tables for laboratory amp site e WebCert feature for online certificates EasyCal Calibration Software www timeelectronics com gt c Reminder letters Unit for test is Unit is checked Testing is done Results reports Certificate is and emails are received and and workload is using TE calibrator are stored issued and unit sent to owner booked in scheduled and EasyCal and printed is returned aoo Pre Cal A Cal E a Post Cal aT EasyCal For the Calibration Process Automating the calibration process brings important benefits and provides increased speed of calibration and consistency of results Pre Calibration The calibration management features of EasyCal make the planning and organisation of instrumentation calibration simple A recall reminder system informs the user of upcoming jobs and search functions allow the user to quickly identify a unit for test Calibration EasyCal controlled calibration significantly decreases testing times meaning less instrument downtime and faster turnaround This improves throughput meaning greater return on investment
43. les can be fitted to the primary console creating a highly flexible system that is both functional and easy to use Further expansion can be achieved by adding the secondary console mounted under the primary Calibration Benches Comprehensive modular test benches and complete laboratory design Calibration modules cover electronic signal temperature loop and pressure applications Power supplies multimeters oscilloscopes and generator modules can also be fitted into the bench consoles Functions are clearly defined on each module and a competent technician will quickly master the operation of the system without training or constant reference to manuals Various fittings functions and additional devices can be added to CalBench to create a comprehensive work environment Calibration Benches www timeelectronics com Module Options and Extras Pressure Precision calibrators indicators and controller modules Ranges from vacuum to 600bar Power Supplies Fixed and adjustable AC and DC power supplies dual and programmable units Loop and Temperature High accuracy loop calibrator modules with Source measure and sink functions Temperature calibrators capable of measuring and simulating RTDs thermocouples Multifunction Calibrator and DMM Modules The 7051 provides high accuracy multi product calibration and has an internal 6 digit multimeter Also available are the 5065B 6 2 digit and 5075B 7 digit multimeter m
44. m weight 5 5kg 11 Electrical Test Calibrators www timeelectronics com L e RCD 3mA to 2500mA 10ms to 2000ms e Loop 50mQ to 1 8kQ e Insulation up to 2GQ 1kV e Continuity 0 10 to 10kQ e RS 232 USB Control Fast and intuitive user interface e PC laptop control via EasyCal software e w430 x H155 x D255mm weight 8kg A precision instrument designed to calibrate RCD loop insulation earth testers and multifunction installation testers The 5030 accurately simulates RCD trip times and measures currents produced by RCD testers It replicates loop impedance and auto adjusts for local line impedance It also provides insulation resistances and measures test voltages and currents Loop TOE 1800 330 0 180 0 33 00 18 00 3 300 1 800 0 5 of displayed value 30mQ 0 330 0 150 amp 0 0500 Test Current 30A max 200ms 50W max Local Loop Compensation 0 5 of value 30mMO RCD Current 0 5 of rdg 1 of rdg with x5 multiplier Phase Detection OOOO OO eee Pre Trigger Threshold Insulation Resistance 1 of value 0 5mA or 1 0mA Load 1 of reading Continuity Resistance aa or Voltage Line Voltage Measurement 0 5 of reading Line Frequency Measurement 0 1 of reading 5030 Electrical Tester Calibrator 12 Multitunction Caliorators Precision calibration for wide workload coverage D025E amp 5025C Multifunction Calibrators e 0 to 1050V AC DC voltage e 0 to 22A AC DC current e 1 to 1GQ
45. m 100V DC AC RMS Temperature Coefficient a 50ppm C Dimensions Weight w215 x H100 x D120mm 1kg incl protective boot Features Colour coded digits safety terminals and protective rubber boot 1061 6 Decade Resistance Box Range Resolution 0 000 000 cte ttt O to 1 2MQ 1Q steps PRC CUE AG niee pene nat eaU E a aE a A 1 Residual Resistance 2000000000000 Less than 150mQ Power Rating 2 0000 e ec teetttteeee 0 75 watt per resistor Voltage Rating Maximum 300V DC AC RMS Dimensions Weight 0000 0 oo W355 x H63 x DB2mm 0 75kg Features cece Slim line design and front panel safety terminals Decade Boxes 1067 6 Decade Precision Resistance Box Range Resolution 0 0 00 ccc ceetteee O to 12kQ 10mQ steps Accuracy 0 01 of setting 2mQ after deduction of residual resistance Residual Resistance Less than 10m Q Less than 1mQ variation Power Rating 2 2 00 eteteeen 0 35 watt per resistor Stability 00000 20ppm year gt 10 100ppm year lt 1Q Voltage Rating cece een Maximum 200V DC AC RMS Insulation oo Case to resistance terminals 2kV 50Hz maximum Temperature Coefficient 0 000 000 10ppm C 20ppm C below 1Q Dimensions Weight oo ccc W355 x H63 x DB9mm 1 1kg Contacts n Make before break silver alloy 1065 6 Decade Power Resistance Box Range Resolution 2 0 00 ccc tteee O to 120kO 0 10 steps PAX C010
46. mess 1620 test point adaptors and micro bore hose for high pressure e 10 adjustable spanner and PTFE tape e Kit supplied in adaptor case with partitioned top section for hoses and extras Pressure Calibration Instruments 10 Electrical est Calibrators Instruments for rapid calibration of electrical test equipment 5068 Insulation Tester Megohmmeter Calibrator A precision instrument for calibrating general purpose insulation testers and megohmmeters with test voltages up to 2 5kV Rugged compact and portable it is ideal for site calibration e Insulation resistance from 100kQ to 10GQ e Low ohm verification at 10 10Q 100Q 1kQ e Accuracy Resistance 1 of setting Voltage and Current to 1 of reading e Up to 2 5kV operation e Battery operation over 150 hours between charges e Continuous connection no arcing e Fully shrouded safety connectors e Display of open circuit voltage 0 to 1 999kV or O to 2 50kV e Display of short circuit current 0 to 2mA or 0 to 20mA e W270 x H175 x D250mm weight 2 1kg 5069 Insulation Tester Megohmmeter Calibrator A high accuracy calibrator for insulation testers and megohmmeters with test voltages up to 10kV Sturdy and transportable it is suitable for both lab and site calibration e Insulation resistance from 100kQ to 100GO e Accuracy Resistance 1 of setting Voltage and Current to 1 of reading e Up to 10kV operation e Battery operation over 150 hours between charges
47. nd F versions available based on 1049 RTD temperature calibrator based on 7000 Temperature and process calibrator based on 1090 Process calibrator Module based on 7050 Temperature distribution Module Thermocouple and RTD Precision loop calibrator based on 7005 V I loop calibrator based on 1048 Loop ancillaries module DMM and Electrical Electronic Test Modules CalBench can be fitted with digital multimeters from the Time Electronics range These include the 5065 6 5 digit dmm and the 5075 precision multimeter The 7051 multifunction module also incorporates a 6 5 digit multimeter housed internally For electrical test applications the 5068B can be bench fitted for the calibration of insulation testers up to 2 5kV Also available is the 5030B electrical tester calibrator e 5065B 6 5 digit multimeter see 5065 benchtop version e 5075B Precision digital multimeter see 5075 benchtop version e 7051 Integral 6 5 digit multimeter equivalent to 5065B e 5068B Insulation tester calibrator See 5068 benchtop version e 5030B Electrical tester calibrator see 5030 benchtop version e 7033 High Precision LCR Meter Module 12Hz to 200kHz e 9758B DC electronic load 80A 80V 300W M a a et Per e sii 21 Calibration Bench Modules www timeelectronics com Signal Generation and Analysis Modules CalBench can be fitted with various frequency counters function generators RF signal generators and EMC test modules
48. ng a wide variety of instruments and devices is included as standard Electrical Testers RCD Insulation PATS Process Contral Equipment mA Loop Thermometers and Temperature Calibrators Decade Boxes Calibrators and Standards Procedure Templates Mechanical Devices Verniers Torque Wrenches Procedure templates for multimeters clamp meters Other decade boxes insulation testers and more can be Manual procedures are For use win used for creating any new procedures as required manually control calibrating equipment Browse Manual Procedure Library Fast Procedure Creation and Editing Copy and paste multiple tests Globally edit a group of tests Colour coded listing helps sort and identify ENNEA REANE NERSE different test types te Procedure Simulation agp vR e Seming Rescmuten 0 0007 The Calibration Run Simulator enables a procedure to swing cena m005 ber 5 be tested without the need for a controlling instrument To further assist with develooment of procedures a test p Fuon Pressure Aim can also be edited during the actual calibration run aee ae a a Format Certificates Resonmon ao Colour code and add borders to test group titles Add Details l column headers where a change of layout is required A Pipam OSES Ee parot penam f E Calculated Error Number of Test Pans 6 preview feature allows the user to check the certificate semner ot Devees unter teat FS
49. nnection So even the most complex calibrations can be performed with relative ease ga ae pga ii _ m Graphical Test Screen E aa The calibration run is made simple and efficient by a graphical user interface which increases speed of data entry The colour coded indication bar displays the test limits This allows the operator to easily identify out of tolerance results Test Control At any stage during the calibration run a summary can be displayed this includes both completed and remaining tests Colour coding indicates tests passed or failed The operator is able to move forward or backward through the procedure as required End of Calibration Run Data for every test is stored including a snap shot of the procedure used If required calibration comments and service history can be updated The operator is able to print the certificate produce a calibration label and or store the results to be issued as required Recovery Mode If for any reason a calibration run is interrupted recovery mode allows the user resume from the point of termination Calibration Test Forms Alternatively calibration test forms for hand written results are available This data is then entered manually into EasyCal at a later date 29 Instrument and Device Calibration www timeelectronics com Certificates Reports Data Management Produce print and store calibration certificates reports and labels Simple search faciliti
50. nstrument for calibrating a wide range of oscilloscopes frequency meters and timer counters It provides outputs for amplitude frequency period duty cycle and bandwidth Frequencies are generated from an internal 0 1ppm temperature controlled oscillator e mV to 220V square wave DC e Frequency 0 1Hz to 100MHz e Time marker period 10s to 10ns e Fast rise lt 300ps e Bandwidth check up to 600MHz e Optional 2 2GHz levelled sweep e Rubidium frequency reference option e Front panel operation e Virtual PC calibrator control software supplied as standard e PC laptop control via EasyCal software e W451 x H152 x D272mm weight 8 2kg ATE Bench Calibrators and Digital Multimeters 5077 Power Calibrator A high accuracy power calibrator suitable for calibrating watt meters power meters and kW Hr meters Supplied with Virtual Front Panel software the user can control the 5077 remotely via laptop or PC e Phase angle 90 power factor 0 00 to 1 00 e 1mV to 1050V AC DC e 0 02 to 22A AC DC e 0 to 22kVA or O to 22kW e 100A AC current transformer option e 45 to 400HZ in 0 1Hz steps e Clamp meter adaptor option e RS 232 GPIB and USB interfaces e Virtual PC calibrator control software supplied as standard e W455 x H155 x D480mm weight 16 5kg PC Virtual Control 5065 Bench Digital Multimeter A versatile 61 2 digit bench multimeter with 19 measurement functions Low cost easy to use stability and high accuracy
51. o data and programs e Office stations can keep track of job and customer information Add necessary details to database m Edit update any changes to personnel job requirements and schedules Print and issue hard copy job reports for internal use and documentation to accompany outgoing instruments Produce reminder reports issue certificates and send emails and letters to customers EasyCal Networking Specific PDF calibration certificates can PDF be located quickly and easily using gt lt WebCert s simple search function _ The user can print calibration certificates la for instruments as required This is m especially useful when certificates are lost or misplaced 32 Product LIstings Ordering information for Time Electronics products UKAS Calibration Certificate e a Z 2 1S RO Rechargeable Battery Pack Carry Case s T 2 O Factory EasyCal Software Decade Boxes C114 C114 C114 C114 C114 C114 C114 C114 C114 C114 opt 9026 opt 9026 opt 9026 Portable Voltage Current Loop amp Temperature Instruments 1006 DC Millivolt Source 0 02 Accuracy C150 1007 DC Millivolt Potentiometer amp Calibrator 0 02 Accuracy C150 opt 9026 opt 9026 C100 C101 C102 C109 C105 C106 C110 C133 C138 C114 C114 C108 C139 C194 C195 C145 C144 C192 opt 9027 opt 9027 opt 9021 opt 9529 opt 9529
52. odules Additional Modules Further modules include oscilloscopes frequency counters function generators and harmonics analyzers Custom design modules can be fitted allows the user to integrate a familiar instrument into their system 7051 Multifunction Calibrator and Control Centre Mounted centrally in the primary console the 7051 combines a precision multifunction calibrator 6 digit multimeter and industrial touch screen PC It is the principle module for on site facilities that require high performance calibration and maximum functionality Calibrator Provides a wide range of calibrated outputs for AC DC voltage and current RTD and thermocouple simulation plus a range of resistance and frequency functions Internal options can be added for increased capabilities These include high voltage and current capacitance and inductance and oscilloscope calibration Further enhancements can be made by additional side modules adaptors and benchtop instruments Digital Multimeter The integral 6 digit multimeter can measure DC voltages to 1000V AC voltages to 750V resistance to 100MQ and frequency to 300kHz PC Control Centre The 7051 control centre is a PC with a 64 bit dual core processor running Windows 8 1 with a 10 4 capacitive touch screen display An optional PC upgrade with 12 1 display is also available The calibrator control software allows the wide range of functions to be easily selected using mouse keyboard
53. pment This can be scheduled before or after installation and can include additional training if required Factory acceptance testing and bench training at TE UK Customers can visit Time Electronics UK and receive training on their ordered system prior to shipment We will schedule and arrange all aspects of the visit including local transport and accommodation Factory acceptance testing can be undertaken by the end user or their designated inspection company Online EasyCal training Using remote desktop sharing we can help customers understand and utilise the software for calibration work and management We can provide basic tutorials or troubleshoot specific applications relative to the user s system Laboratory Design and Supply 24 Manage Automate and Optimise the Calibration Process About Easycal EasyCal is a complete software package with features covering all aspects of calibration work and management It is designed to reduce workload improve efficiency and provide the essential platform for companies looking to create and sustain an effective calibration program The comprehensive features simplify the administration process from reminder reports through to despatch With a familiar and intuitive user interface all operators can quickly learn and navigate through the applications This allows fast straightforward implementation and integration of the software Communication and Control EasyCal a
54. r the main testing and verification workload The process starts by understanding the user s requirements and applications Once this is determined the design team will firstly configure the suitable calibration bench or benches and if necessary add supporting instruments for customer specific applications Following this the workspace dimensions are supplied and the virtual design begins Using custom software we create a 2D overview of the laboratory then generate 3D images and videos to allow the end users to visualise the concept 1200mm 1000mm lt 6400mm b 2000mm Laboratory Design and Supply Turnkey workshop design service and supply Each laboratory is designed to optimise the calibration process This is accomplished by a dual approach of hardware and software CalBench modules provide the functions to calibrate devices and instruments whilst EasyCal software is the controlling platform for all work and management It enables the operators to schedule workload organise jobs database and print store information It also speeds up calibration by automating test runs when used with the 7051 multifunction calibrator DMM or other compatible bench modules and instruments In addition to the primary focus of calibration the lab can incorporate customer designated areas of use These could be stations for administration work repair and maintenance or storage units Laboratories can be designed to be fully self suff
55. ranges 15ppm Inductance 1mH 1 9MH 5MH 10MH 19MH 50MH 100MH 190MH 500mH 1H 10H 0 1 of setting 5025E and 5025C External Options 9780 Clamp Meter Adaptor 1 amp 50 turn coil 9773 Optical Tacho Adaptor 9790 100 Amp AC Current Transformer External Adaptors Instruments 9760 Power Amplifier GOV AC 90V DC 100mA 9762 Rubidium High Stability Frequency Reference 9764 Current Probe Calibration Adaptor 9766 Low Noise Attenuator 1000 1 9767 Low Noise Attenuator 100 1 Accessories 9085 Soft Carry Case 9059 Hard Transit Case 9728 19 Universal Rack Mount Kit 9796 Premium Test Lead Set and Calibration Certificates Factory Certificates NPL traceable C159 for 5025E C220 for 5025C e UKAS Certificates ISO 17025 C103 for 5025E C225 for 5025C ECFLA EasyCal Full License 9777 Bar Code Reader 9779 Job and Address Label Printer EasyCal Software d i EC2FL EC2WL Additional User Licenses EAD EasyAdmin Add On EWC WebCerts CREP Crystal Reports Software General Specifications Supplied Accessories Basic Test Lead Set PC Virtual Control Software RS 232 Cable RS 232 to USB Adaptor e User Manual Warm up 30 minutes to full accuracy Temperature Performance Operating 5 to 45 C Calibration 15 to 28 C Storage 10 to 50 C Operating Humidity Altitude lt 80 non condensing Altitude 0 to 3km Non operating 3km to 12km Line Power 100 to 230V AC 50 60HZz 200W maximum Interfaces R
56. riranias eit 11 Sovereign Vay Teabridge Kent THO IA Tell ST Ses Fao Him THAT MARTH ANDREWS Sal bp Combes a rii Caddies a pi a Ta UL TTR ean UNF Hatikan dH rimia SETA Tii Eeppi Arer jgan FETAI DER 1 cS Bmmairm CRC igi Eaki Mighing Paiiay 7000 Litaa 10000 fa epy a p MN o Te TE ARE RS DE mAT KETE TENEN MPENN TN g Ea Hiiti dE ikinni a Gr Envim menial Camdiinns THE etre PEDE Dire Arame Pam ery bii ii CALIBRATION REPORT Hiius Dy Laboratiry Sone VERRA FI iiw Rass jim Certificate Burien MEID003 Gaai Fag Pee Thee Gente gee Tracii La Lm UALS PPE ear bb Bes Wii Pir LE LL LLE tg be _ Se 2S woe it Certificates Reports Data Management Cela bes Garie Biessen Wii Cee Daie Di decae PAK jija oig ipepe iie aiD iii E CE TH ina Sh Pa Tima this DEERE EPET TFELNG arti D aha il a ije A pje a 2E Faja CEET TIALO TEST GF PET R Ske GS ssh iog am Cert al OOOO l l UE Feti Explorar Dem whai ey p ei a 3 ES 4 Cerificate umber gt i CERTIFICATE OF CALIBRATION E nes on poy ee Foe Do tomb Tt iii oe Labacdri r i Lab ddr i aan 3 Addii l 3 EE Pitt Eptarer i Report Explorer 30 oe User nformetisn mewaa fm w Emak feeca EF Urar iea Calton Operator ful Access o Caton Syw ad operators in Cafn I liter ia a Signatory WebCerts Select Certificate Webterts
57. sl sloc Q S O 2 me amp O g allo OWess es 2 e oe 8 Se 2 H H i 40 Om MAO o o T ce ce ns O O gt C gre gt iz t A Lt oS ob Multifunction Calibrators Fol Ss Ie S So lt S MElWE Flos G8 Os aesg os ee Floslos eE E ORE R i mr E rc N o2alaovloslacoclxsaslo8tl oLgjloojlomea t listed ee LO a oO a Reki Ren oa S R SlGSl aSlo8loszlatl aostlaosinr a main Options IISte RO OMIK OI go OsI ROIJROITR OTR GIR OJRYLITR SER SETRATR OTROUOINRG Ti Oe i ke OFILoO amp OIFSIWWT aI aI anDIDOToaIToaLI Tar _ nOTnO loontToct oc O 5025E Entry Level Multifunction Calibrator C220 C2 ol ig 5 N O Oo1 amp lt 9085 Carry Case 9082 for 5051 lt 5025C Multifunction Calibrator lt Q oo BS O O 5051 Multifunction Calibration System noj o cn m F cn ol ol z 8 5 enone re Te HSCS Blo Sle oS lool Slog odleslostleslosl sle8 co Te Te o lo mMlLOVSPoDIrSfloVBloQloVloVpfoVslaVi H Vls8 Communication Accessories SHOISOIXAIZAILSSISS SolSdISacalTSalsalsalsoalsals a 2al2alea Sel SeclSeloelSelSe Sd Secl SolScelRel RelRelRelReclkRecleeclee O 9588 RS 232 Cable 9597 GPIB Cable 9794 GPIB to USB Interface Adaptor 9765 RS 232 to USB Interface Adaptor 9763 USB to 4 x RS232 Interface Adaptor 9743 PCI to GPIB Interface Card for PC Has Gas HER Has Gd Has Haid Gas Haid Has Haid Haid Haid Haid Haid Haid Haid Haid O EasyCal Licenses Add Ons and
58. stem For The Calibration Process The 5051 Plus is an inclusive package with features to cover and optimise the entire calibration process By integrating the calibrator multimeter and PC in one unit minimal bench space is used This also makes the 5051 ideal for site work with carry case supplied as standard The internal PC is preloaded with the EasyCal software suite enabling automatic calibration to increase speed and efficiency of work In addition EasyCal has features to manage and administrate both inventory and quality control As a complete workstation the 5051 Plus is supplied with printer and connectivity kit for producing certificates and reports 15 9051 Plus Multifunction Calibration System www timeelectronics com 5051Plus Specifications Calibrator Source Voltage DC Current DC Voltage AC Current AC Clamp Meter Adaptor x50 turn Capacitance Inductance Decade Resistance Full Range Resistance Conductance Thermocouple Simulation PT100 Simulation Oscilloscope Calibration Amplitude Frequency Period Duty Cycle Fast Rise Option 9769 Scope 2 2GHz Sweep Range Values Best 1 year Specification O to 1050V Oto 22A 1mV to 1050V 10Hz to 1MHz sine wave 15ppm of setting 80ppm of setting 300ppm of setting 10UA to 22A 20Hz to 1kHz sine wave 0 05 AC DC Current up to 1100A DC 45 to 90Hz 0 5 0 1 10 to 1GQ decade values 10 to 120MQ variable 1s to Ins fixed
59. t measure e 24 36V loop power e Over pressure alarm e RS 232 serial interface and EasyCal software compatible e W270 x H175 x D250mm weight 3kg 7016 Regulated Low Pressure Calibrator 7018 Differential Pressure Calibrator Portable pressure calibrators that are rugged design and simple operation ideal for field calibration applications Models available from vacuum to 10bar 145psi e 7016 Regulated low pressure Vacuum 0 2 2 5 or 10bar versions e 7018 Differential pressure 0 2 2 5 or 10bar versions e Pneumatic with 0 04 of full scale best accuracy e 4 selectable pressure units and mA e Loop current measure e 24 36V loop power e Over pressure alarm e RS 232 serial interface and EasyCal software compatible e W270 x H175 x D250mm weight 3kg 7198 Pressure Calibration Accessories Kit A comprehensive set of pressure accessories to accompany pumps gauges and calibrators The 7198 kit includes adaptors fittings connectors and hoses to provide a quick solution to pressure component requirement in both the field and laboratory e Adaptors for metric BSP parallel taper threads and NPT male and female e Coupling connectors included allow any two adaptors to be connected together e 1 4 BSP hose fittings for pushfit 4mm and 6mm external diameter hose e Nylon hose set with quick release connectors for low pressure connections e Additional 4mm and 6mm nylon hoses to build up custom lengths as required e Mini
60. tep e PT100 plus 7 other RTD types e User programmable e 24 hours typical use between charges e Supplied with battery charger and carry case e H165 x W90 x D45mm weight 0 42kg 1090 Process and Temperature Calibrator A portable key press operation instrument that combines source and measurement functions for thermocouples RTDs mV and mA The 1090 features a memory storage function that holds frequently used values e Measures simulates 8 thermocouple types PT100 RTD mV and mA e Displays units in C F uV mV or mA e Accuracy Source 0 02 of range 0 5 C Measure 0 05 of range 0 7 C e Automatic or manual cold junction compensation e Inching and step functions with time configurable steps e Process loops 4 to 20mA and 0 to 50mA e Mains or battery operation 60 hours typical use between charges e Supplied with battery charger and carry case e H235 x W150 x D 5mm weight 1 2kg 7050 Process and Thermocouple Calibrator A process calibrator that combines the essential functions of measurement and simulation of volts millivolts milliamps and ohms with the direct readout simulation of thermocouples and RTDs in C or F units e Measure 3 ranges up to 40V 400mA 40kQ e Output voltage 3 ranges up to 10V 1uV resolution e Output current 3 ranges up to 20mA 14A resolution e Output Resistance 3 ranges up to 40kQ 0 01Q resolution e Accuracy Source and measure 0 03 of range e Thermocouple measure and s
61. use with smooth pressure generation and high pressure stability e Dual pressure source double output manifold e Fine pressure adjustment e 7193 w198 x H140 x D3815mm weight 2 7kg e 7194 w270 x H178 x D450mm weight 7 5kg e 7195 w198 x H135 x D290mm weight 3 2kg 7089 7091 7094 7096 Digital Pressure Gauges Digital pressure gauges that provide high accuracy resolution and stability Robust design and simple operation make these gauges ideal for a wide range of applications e 7089 Vacuum only accuracy 0 2 of FS e 7091 Vacuum to 40bar 600psi accuracy 0 2 of FS suitable for the 7090 7193 e 7094 0 to 100bar 1500psi accuracy 0 2 of FS suitable for the 7194 e 7096 0 to 700bar 10 000psi accuracy 0 2 of FS suitable for the 7095 7195 e Easy to read display with 5 digit resolution e Unique self protection capability technology e 3 times per second measure speed e Fully temperature compensated accuracy e RS 232 connection on rear of gauge EasyCal compatible e H178 x W112 x D45mm weight 0 6kg 7078 Auto Ranging Digital Pressure Gauge A high performance digital pressure gauge that has the ability to auto range and maintain a 0 1 of reading accuracy from vacuum to 200bar The 7078 eliminates the need for multiple gauges to span many different ranges solving the problem of over ranging errors e Vacuum to 200bar 3000psi e 0 1 of reading accuracy e 9 engineering units bar psi
62. utomates calibration runs by allowing the user to remotely control and communicate with compatible calibrators and DMMs User friendly features and controls aid the process to further decrease calibration times EasyCal can also read back values and data from compatible Time Electronics pressure and process instruments and can be used with external instruments such as dry block calibrators For Multiple Industries and Disciplines EasyCal is a versatile solution to multi device calibration with the comprehensive functionality that is required across industries It is globally used as the principal software in both calibration businesses and companies with on site test facilities EasyCal is also designed for universal testing applications and can cover a wide range of disciplines Users can calibrate and verify various instruments and devices electrical and electronic level pressure and flow temperature and loop mechanical and dimensional FasyCal Calioration Software The comprehensive solution to calibration work and management FasyCa mi welll F Time Electronics hi ry S a ei j et A TUNE Fia m EVN iia 1 ati We Features e Communicate with calibrators DMMs bench modules Automated planning and scheduling e For use with multiple devices and instruments e Print email store certificates and reports e Network compatible e Produce calibration labels e Quickly generate procedures using templates e 1200 pre wr