Home

TPH100 User Manual

image

Contents

1. 100 100 OPERATING THE TPH100 HUMIDIFIER Filling the Water Tank Always place humidifier on a firm flat and level waterproof surface Keep cord away from heated surfaces or where it could be stepped on or tripped over Position the rotatable mist spout so that the mist will spray away from any furniture or electrical appliance to avoid water vapor damage Step 1 ENSURE THE UNIT IS TURNED OFF AND UNPLUGGED Take the water tank out from the humidifier Step 2 Lift the tank lid counterclockwise to open and fill with clean cold water Step 3 Twist the tank lid clockwise to close the tank and then invert the tank and check for any leaks Step 4 Lower the water tank back onto the humidifier base Step 5 Plug in the power cord and press the POWER button to turn on the humidifier Step 6 Adjust the rotatable mist spout to the desired direction ess OPERATING THE TPH100 HUMIDIFIER Low Water Alert Feature The Therapure Humidifier has a built in low water alarm system Whenever the water tank is about to empty a beeping alarm will sound and the unit will also automatically shut off operation The alarm will continue sounding until either the unit is turned off via the Power button or the water tank is refilled with water Controls Settings Power Press the Power button to turn the unit on and off Speed Setting The Therapure Humidifi
2. plug READ ALL INSTRUCTIONS BEFORE OPERATING THE HUMIDIFIER The humidifier should be placed away from any heat source such as a stove or fireplace other appliance or electronic device Avoid direct sunlight on the unit Disassembly or repair of the unit by any unauthorized person including yourself will void the warranty and may result in serious harm Do not operate the unit if room temperature is lower than 41 5 C or higher than 104 F 40 C or if relative humidity is higher than 80 Do not operate the unit with a damaged cord or plug or after malfunctions or if the unit has been dropped or damaged in any manner Keep this product out of the reach of children and pets Do not move the unit or remove the tank while the unit is on When disconnecting the unit first turn unit off then remove plug from outlet Always turn off the unit and unplug the power cord before filling the water tank Do not fill the water tank with hot or boiling water Do not use the unit if the water tank becomes cracked or damaged Do not immerse the unit base in water or pour water into the mist spout Always turn off the unit and unplug the power cord from outlet before removing attaching or cleaning the water tank on the unit Avoid placing this unit where the mist spout is pointed directly at an object Do not clean the water tank with detergents or chemicals of any kind Do not cover the humidity opening at any time during use Alway
3. unit including inside the water tank 3 Pack into the original box and store in a cool dry place TPH100 TPH100 TROUBLESHOOTING PROBLEM No mist There is an unpleasant smell in the mist There is a strange noise Mist is spraying from around the mist mouth REASON The plug is not connected properly The power is off Turn on the power No or too little water in the tank 1st time running Water is not clean or was left in the tank for a long time Water tank is not properly placed on the base Water level in the tank is too low Mist spout is not properly placed on the tank SOLUTION Insert the plug correctly Fill water tank Rinse the water tank with clean water Clean the water tank refill with clean water Set the water tank properly Add water Re seat the mist spout TECHNICAL SPECIFICATIONS Model TPH100 Voltage 120 VAC 60Hz Power Usage 130W Maximum Humidity Capacity 2 5 gallons per day warm mist 1 9 gallons per day cool mist Tank Size 1 6 gallons TPH100 TPH100 LIMITED WARRANTY ONE YEAR LIMITED WARRANTY Your Therapure TPH100 Humidifier is warranted to be free from defects in materials and workmanship for one year from the original purchase date Should the product have a defect in materials or workmanship we will repair or replace it without charge to you a shipping and processing fee will apply To obt
4. NY WITHIN THIRTY 30 DAYS OF RECEIPT FOR A FULL REFUND THIS ARBITRATION AGREEMENT AGREEMENT AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY PROVIDING THAT DISPUTES BETWEEN YOU AND THE MANUFACTURER DISTRIBUTOR AND OR SELLER OF THIS PRODUCT COLLECTIVELY MUST BE RESOLVED THROUGH BINDING ARBITRATION AND NOT IN COURT IT ALSO PROVIDES THAT ANY DISPUTE CANNOT BE RESOLVED IN A CLASS ACTION OR OTHER PROCEEDING WHERE YOU REPRESENT OTHER PERSONS OR OTHER PERSONS REPRESENT YOU AND THAT NO CLASS OR REPRESENTATIVE ARBITRATIONS ARE PERMITTED PLEASE CAREFULLY READ ALL TERMS IN THIS AGREEMENT RESOLUTION OF CLAIMS OR DISPUTES Any claim or dispute between you and Company or any of Company s subsidiaries or affiliates arising out of or relating in any way to the Product or this Agreement shall be resolved through final binding arbitration This arbitration obligation is reciprocally binding on both you and the Company and applies regardless of whether the claim or dispute involves a tort fraud misrepresentation product liability negligence violation of a statute or any other legal theory Both you and Company specifically acknowledge and agree that you waive your right to bring a lawsuit based on such claims or disputes and to have such lawsuit resolved by a judge or jury N LIMITATION OF LEGAL REMEDIES All arbitrations under this Agreement shall be conducted on an individual and not a class wide basis and an arbitrator sh
5. ain service under warranty simply call our customer service center toll free at 1 800 554 6168 This warranty does not cover damage caused by accident misuse or any use other than as intended and described in this product manual or damage resulting from failure to maintain and clean this product as specified in this product manual This warranty applies only to the original purchaser of the Therapure TPH100 Humidifier ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE WARRANTY PERIOD AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THIS PERIOD Some states do not allow limitations on the duration of implied warranties so the above limitation may not apply to you While this warranty gives you specific legal rights you may also have other rights which may vary from state to state Contact Info for Warranty Service Therapure by Envion LLC Box 9169 Van Nuys CA 91409 8291 1 800 554 6168 www envionproducts com 2011 Envion LLC All rights reserved Patents pending ARBITRATION AGREEMENT PLEASE READ THIS AGREEMENT CAREFULLY YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT S SHIPPED IN CONNECTION WITH THIS AGREEMENT THE PRODUCTS FOR MORE THAN THIRTY 30 DAYS AFTER RECEIPT IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT YOU MAY RETURN THE PRODUCT TO COMPA
6. all have no authority to award class wide relief You acknowledge and agree that this Agreement specifically prohibits you and the Company from commencing arbitration proceedings as a representative of others or joining in any arbitration proceedings brought by any other person The parties agree that no class or representative actions of any type are permitted ARBITRATION PROCEDURES Before instituting an arbitration if you have any dispute we strongly encourage you to contact the Company to try to resolve the matter by calling 800 218 3560 although you are not required to do so The arbitration of any claim or dispute under this Agreement shall be conducted in accordance with the expedited procedures set forth in the JAMS Comprehensive Arbitration Rules and Procedures as those Rules exist on the date you receive the Product including Rules 16 1 and 16 2 of those Rules These rules and procedures are available by calling JAMS or by visiting its web site at www jamsadr com The arbitration of any claim or dispute under this Agreement shall be conducted by an arbitrator who has at least five years of experience conducting arbitrations The arbitration of any claim or dispute under this Agreement shall be conducted in the State of California or the location in which you received this Agreement For claims of 10 000 or less you may choose whether the arbitration proceeds in person by telephone or based only on submissions The Comp
7. any shall pay costs for the arbitration of claims including any JAMS Case Management Fee and all professional fees for the arbitrator s services The Company shall pay the fees and costs of its own counsel experts and witnesses and shall not be able to recoup them from you even if you do not prevail in the arbitration Unless otherwise provided by law you acknowledge and agree that you shall pay the fees and costs of your own counsel experts and witnesses gt CHOICE OF LAW The arbitration provisions of this Agreement and any arbitration conducted pursuant to the terms of this Agreement shall be governed by the Federal Arbitration Act 9 U S C Secs 1 16 In this respect the parties acknowledge that this Agreement involves a transaction conducted in interstate commerce Otherwise this Agreement and the rights of the parties hereunder shall be governed by and construed in accordance with the laws of the State of California exclusive of conflict or choice of law rules SEVERABILITY If any provision of this Agreement is declared or found to be unlawful unenforceable or void such provision will be ineffective only to the extent that it is found unlawful unenforceable or void and the remainder of the provision and all other provisions shall remain fully enforceable TPH100 TPH100 100 100
8. er has 3 mist settings LOW MED and HIGH Press the Speed button to cycle through the settings and select your desired setting The mist setting will be shown on the LED display of the control panel Timer The Therapure Humidifier can be programmed to turn off after a preset amount of time Press the Timer button to program the timer Each press of the button will add 2 hours reaching a maximum of 8 hours After 8 hours the timer control menu will cycle back to 2 hours The timer setting will be shown on the LED display of the control panel Warm Mist Setting The Therapure Humidifier is equipped with a warm mist feature To activate this feature press the Cold Hot button once A warm mist indicator will light up in the control panel indicating this feature is on Press the Cold Hot button again to turn off the warm mist feature SaaS gt Humidity Control To adjust the humidity level es press the Set Humidity button Each press of the button will add 5 humidity While setting theralpure the control panel will flash the setting value Keep pressing the button until the desired level is reached The display screen will stop flashing after 4 seconds and your humidity level is set The humidity settings start at 40 and can be set up to an 80 humidity level After 80 the next level will be infinite level which means the unit will zma produce mist continual
9. ly until shut off Fa Note The working environment for the humidifier is 41 F to 104 5 40 and with relative surrounding humidity of 80 RH or lower ay a Note Scientific research has shown a humidity level of 40 to 60 can reduce flu viruses in the air and on surfaces TPH100 TPH100 CONTROL PANEL TIMERS HUMIDITY CONTROL PANEL CLEANING amp MAINTENANCE To keep the Therapure Humidifier functioning properly and at maximum performance it is recommended to clean the unit once a week Always turn off and unplug the unit first before doing any maintenance Do submerse the unit in water or allow water to enter inside the unit CAUTION Water inside the unit may be hot Allow the unit to cool down for 5 minutes before performing any maintenance CLEANING THE UNIT BASE 1 Pour out all the water the unit base 2 Wipe the outer surface of the unit with a soft damp cloth 3 Rinse out and wipe down the inside of the base with clean water by using the cleaning brush included and a soft cloth if needed 4 f there are hard water deposits inside the ultrasonic nebulizer add a solution of 50 white vinegar and 50 water to the ultrasonic nebulizer Let the water soak for 5 minutes Clean the ultrasonic nebulizer with the cleaning brush until the scale is removed Rinse the ultrasonic nebulizer with clean water CLEANING THE WATER TANK 1 Pour
10. out all the water in the tank 2 Rinse the water tank with clean warm water 3 Ifthe tank has hard water deposits add small amount of white vinegar into the tank and fill half the tank with warm water Tighten the tank lid and shake the tank several times before emptying the water Rinse the tank with warm clean water again before using DEMINERALIZATION FILTER REPLACEMENT To keep the Therapure Humidifier functioning at maximum performance it is recommended to replace the demineralization filter cartridge once every 30 40 fillings under normal use or when the humidifier has not been operated for an extended period of time NOTE Operating the humidifier without a demineralization filter cartridge will require more frequent cleaning of the unit base To replace the demineralization filter 1 first remove the water tank lid 2 from the unit Then remove demineralization filter from the water tank lid by turning it counter clockwise Replace with a new demineralization filter and attach onto the water tank lid in a clock wise direction Then place both pieces back on unit to complete filter replacement process Demineralization filter Water tank lid To purchase demineralization filter replacement cartridges please visit www envionproducts com or call 1 800 554 6168 Part TPH1000F STORAGE 1 Always empty and clean the unit before storage see Cleaning and Maintenance 2 Use a soft cloth to wipe dry the entire
11. s plug and unplug the unit with dry hands Do not add any medication into the nozzle base or water tank Do not turn on or use the unit without water Do not scrape the ultrasonic nebulizer with sharp items If there is any strange noise or smell when operating turn off the machine and unplug the power cord immediately Do not touch the water or parts in the water flume when operating The humidifier requires regular cleaning Refer to the instructions in the user manual 9 Do not attempt to replace the power cable UNIT PLACEMENT To keep the unit steady set it on a firm flat and level waterproof surface The humidifier should be placed far away from any heat source such as a stove or fireplace Avoid direct sunlight on the unit Set the unit far away from other electronic appliances To help prevent water vapor damage position the rotatable mist spout so that the mist will spray away from any furniture or electrical appliances To avoid air saturation and condensation on walls and furniture the humidifier should not be left unattended in a closed room OO OO MAIN PARTS Main mist spout mouth 1 Rotatable mist spout mouth 2 Handle Water tank body Demineralization filter Water tank lid Control panel Control buttons Unit base Ultrasonic nebulizer Power cord N Cleaning brush
12. thera pure thera pure thera pure thera pure o v u POWER SPEED wa TIMER SET HUMIDITY COLD HOT POWER SPEED TIMER SET HUMIDITY www envionproducts com 2012 Envion LLC All rights reserved TPH100 0712 By ENVION By ENVION thera pure By ENVION www envionproducts com TPH100 User Manual TABLE OF CONTENTS SAFETY INSTRUCTIONS IMPORTANT WARNINGS MAIN PARTS OPERATING THE TPH100 HUMIDIFIER Filling the Water Tank Low Water Alert Controls Settings Control Panel CLEANING and MAINTENANCE Cleaning the Unit Base Cleaning the Water Tank Demineralization Filter Replacement Storage TROUBLESHOOTING TECHNICAL SPECIFICATIONS ONE YEAR LIMITED WARRANTY ARBITRATION AGREEMENT TPH100 User Manual SAFETY INSTRUCTIONS READ AND SAVE THESE IMPORTANT INSTRUCTIONS WARNING RISK OF ELECTRICAL SHOCK This product should be used only in accordance with the specifications outlined in this manual Any use other than what is specified in these instructions may result in serious injury POLARIZED APPLIANCE CONNECTIONS To reduce the risk of electric shock this appliance has a polarized plug one blade is wider than the other This plug will fit into the polarized wall outlet only one way If the plug does not fit fully into the wall outlet reverse the plug If the plug still does not fit contact a qualified electrician to install the proper wall outlet Do not change the equipment

Download Pdf Manuals

image

Related Search

Related Contents

Ayuda - Autoridad Portuaria de Ceuta  オーストラリア    Matrix Appliances MHC001FR hob  家庭用ローラー式電気マッサージ器の適正使用のお願い(注意喚起) 布  Tarjeta FireWire IEEE1394 Tipo ExpressCard    Orion 52099 User's Manual  Samsung 2GB DDR3-1333MHz  Téléchargez l`étude  

Copyright © All rights reserved.