Home

48-10/100Mbps + 4G Ethernet Web Smart Switch FGSW

image

Contents

1. PLANET Networking amp Communication 48 10 100Mbps 4G Ethernet Web Smart Switch FGSW 4840S User s Manual Trademarks Copyright PLANET Technology Corp 2004 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been teste
2. Step2 Place the FGSW 48405S on a desktop or shelf near an AC power source Step3 Keep enough ventilation space between the Switch and the surrounding objects When choosing a location please keep in mind the environmental restrictions discussed in Note Chapter 1 Section 4 Specification Step4 Connect your FGSW 4840S to network devices A Connect one end of a standard network cable to the 10 100 or 10 100 1000 RJ 45 ports on the front of the FGSW 4840S B Connect the other end of the cable to the network devices such as printer servers workstations or routers etc Connection to the Switch requires UTP Category 5 network cabling with RJ 45 tips For more Note information please see the Cabling Specification in Appendix A Step5 Supply power to the Switch A Connect one end of the power cable to the FGSW 48405 B Connect the power plug of the power cable to a standard wall outlet When the FGSW 48405 receives power the Power LED should remain solid Green 2 2 2 Rack Mounting To install the switch in a 19 inch standard rack follow the instructions described below Step1 Place your FGSW 48405 on a hard flat surface with the front panel positioned towards your front side Step2 Attach a rack mount bracket to each side of the Switch with supplied screws attached to the package Figure 2 3 shows how to attach brackets to one side of the Switch Figure 2 3 Attaching the brackets to the FGSW 4840S Cauti
3. Contact A 3 RJ 45 cable pin assignment a mM m There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection 35 Straight Cable SIDE 1 1 White Orange 2 Orange 3 White Green d Blue 5 White Blue 6 Green T White Brown 8 Brown SIDE 1 White Orange 2 Orange 33 White Green Blue 5 White Blue 6 Green T White Brown 8 Brown 1234567 8 SIDE 1 Pr TT rli o 1234567 8 SIDE 2 SIDE 1 1 WhitelOrange 2 Orange 3 White Green d Blue 5 White Blue 6 Green T White Brown 6 Brown SIDE 2 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange T White Brown A Brown Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network EM _FGSW4840Sv1 36
4. 1 4 Product Specifications Model FGSW 4840S Hardware Specification 10 100Base TX ports 10 100 1000Mbps ports SFP Mini GBIC interfaces Switch architecture Switch Fabric Switch throughput Address Table 4K entries Share data Buffer 1536KBytes Flow Control Back pressure for half duplex IEEE 802 3x Pause Frame for full duplex Dimensions mm 440 x 200 x 44 mm 1U height Weight 3kg 100 240V AC 50 60 Hz 24 watts 81 BTU iN 00 Store and Forward 17 6Gbps 13Mpps Power Requirement Power Consumption Standards Conformance Network Standards IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3ab Gigabit Ethernet IEEE 802 3z Gigabit Ethernet IEEE 802 3x Full duplex flow control 5 to 90 Non condensing FCC Part 15 Class A CE 2 INSTALLATION This section describes the functionalities of FGSW 4840S s components and guides how to install it on the desktop or shelf Basic knowledge of networking is assumed Please read this chapter completely before continuing 2 1 Product Description The PLANET FGSW 4840S is a 10 100 1000Mbps Ethernet Switch provides 48 10 100Base TX ports respectively with 2 10 100 1000Base T ports and 2 SFP Mimi GBIC interfaces With a 17 6Gbps internal switching fabric the FGSW 4840S can handle extremely large amounts of data in a secure topology linking to a backbone or high capacity servers The FGSW 4840S has a 4K MAC Address table and provides a 1536KBytes frame buffer The
5. 2 3 4 5 6 7 8 Selection 1 Disable Selection 2 port 9 10 Selection 3 port 9 10 11 12 Selection 4 port 9 10 11 12 13 14 15 16 Selection 1 Disable Selection 2 port 17 18 Selection 3 port 17 18 19 20 Selection 4 port 17 18 19 20 21 22 23 24 Selection 1 Disable Selection 2 port 25 26 Selection 3 port 25 26 27 28 Selection 4 port 25 26 27 28 29 30 31 32 Selection 1 Disable Selection 2 port 33 34 Selection 3 port 33 34 35 36 Due to the hardware restriction The port based VLAN function cannot across between port 24 Selection 4 port 33 34 35 36 37 38 39 40 Group 6 Selection 1 Disable Selection 2 port 41 42 Selection 3 port 41 42 43 44 Selection 4 port 41 42 43 44 45 46 47 48 Group 7 Selection 1 Disable Selection 2 port 49 50 After setup completed Press Apply button to execute the setting The trunking screen in Figure 3 35 appears 9 PLANET FGSW 4840S 48 4G Ethernet Web Smart Switch Trunk Setting The selected trunk port setting must set to the same VLAN Group Trunking D Member Maintenance o foLo Statistics los 171619022232 y S ys ta os ae J Logout Figure 3 35 Trunking Setting screen On i Be sure that the selected trunk port must connect to the Switch under the same VLAN group Ote 25 3 1 2 6 Status Click on the Status to present the Switch status on this screen it display the Switch St
6. Lit indicate the link through that port is successfully established Sen Blink indicate that the switch is actively sending or receiving data over that port 2 1 4 FGSW 4840S Rear Panel The rear panel of the Switch indicates an AC inlet power socket which accepts input power from 100 to 240VAC 50 60Hz 100 240V AC 50 60 Hz Figure 2 2 Rear Panel of FGSW 4840S Power Notice 1 The device is a power required device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device may also help to protect your switch from being damaged by unregulated surge or current to the Switch or the power adapter 2 2 Installing a FGSW 4840S This section describes how to install your FGSW 4840S Web Smart Gigabit Ethernet Switch and make connections to the switch Please read the following topics and perform the procedures in the order being presented PLANET FGSW 4840S Web Smart Gigabit Ethernet Switch do not need software configuration To install your FGSW 48405 on a desktop or shelf simply complete the following steps 2 2 1 Desktop Installation To install an FGSW 48405 on a desktop or shelf simply complete the following steps Step1 Attach the rubber feet to the recessed areas on the bottom of the switch
7. When one packet comes from some port of the Ethernet Switching it will also check the destination address besides the source address learning The Ethernet Switching will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it connected If found and the destination address is located at different port from this packet comes in the Ethernet Switching will forward this packet to the port where this destination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in then this packet will be filtered Thereby increasing the network throughput and availability 4 4 Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Ethernet Switching stores the incoming frame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the network thereby increasing throughput and avail
8. describe this VLAN Group check on the port to be a member to this VLAN Group There are two groups for VLAN Setting and only can choose one group in the same time check on the port to be a member to the Port Group 1 or Port Group 2 then press Apply button to execute the setting The screen in Figure3 29 appears J PLANE im FGSW 48405 48 4G Ethernet Web Smart Switch Setup VLAN Setting SEEN Description Trunking Port Group 1 z setting Logout Figure 3 29 Per VLAN Setting screen Once you want to modify the existence VLAN Group press the ID parameter the ID VLAN configuration screen will pop out The screen in Figure 3 30 amp 3 31 appears 21 FGSW 4840S 48 4G Ethernet Web Smart Switch VLAN Setting VLAN D Description Member Trunking 01 Default Maintenance 02 PLANET 01 030507 0911131517 1921 23 gt tatus Figure 3 30 Edit existence VLAN Setting screen 9 PLANET FGSW 4840S 48 4G Ethernet Web Smart Switch VLAN Setting Trunking Maintenance Figure 3 31 Edit existence VLAN Setting screen After edit completed Press Apply button to execute the setting The screen in Figure 3 32 appears 22 vem scoomentioo FGSW 48405 48 4G Ethernet Web Smart Switch VLAN Setting VLAN ID Description Member Trunking 01 Default Maintenance 02 PLANET 25 27 2931 333537 3941 434547 4951 Add Group Delete Group Figure 3 32 Edit existence VLAN Setting screen Delete the existenc
9. to monitor list button to select a device from the Discovery List to the Monitor List The screen in Figure 3 13 appears EI Web Switch Utility File View Option Help Discovery List 005041201 5bc 192 165 0 1 2 001 001 Fissvv 45405 Discovery Add to monitor list de Monitor List IP Address MAC Address Protocol Version Product Mame System Mame view Trap Add tem Delete tem Device Setting Configuration setting Pas weord change Firmware upgrade Web access Exit Figure 3 13 Discover list screen 12 The Discovery List contains nine items MAC Address display the Switch MAC Address IP Address display the current IP address of the Switch Protocol version display the version of the Utility protocol Product Name display the Switch model name System Name display the appointed Switch system name Location display where the Switch is located Trap IP display the IP address where the Trap to be sent Subnet Mask display the Subnet Mask set of Switch Gateway display the Gateway set of the Switch 3 1 1 3 Monitor List All the FGSW 48405 in the Monitor List can be monitored user can receive the trap and view the status of each Switch The screen in Figure 3 14 appears CE Web Switch Utility 2101 x File View Option Help Discovery List MAC Address IP Address Protocol Version Product Mame System Mame Discovery Add to monitor list GE Monitor List IP
10. 37 Statistics screen TTT BBs kele elke Be Re g Press the port ID for detail packet information on each port Press Refresh to renew the posted information The screen in Figure 3 38 appears 26 QP PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Port Statistics Trunki ing Maintenance Bytes 302383 o n 72 Droppkts oo MulticastPkts Do PausePkts BroadcastPkts a FrameinDisc hn LateCollision 0 ExcessiveCollision 0 a A RX Bytes 9002 u UnicastPkts 92 D DropPkts o MulticastPkts 0 PausePkts fo BroadcastPkts 0 ExcessSizeDisc u UnderSizePkts Jabbers 6 64 BytePkts to 127 BytePkts z 128 to 255 BytePkts io 256 to 511 BytePkts 11 D 512 to 1023 BytePkts lo 11024 to 1522 BytePkts lo Figure 3 38 Per port Statistics screen 3 1 2 8 System The System Setting includes the System name Location name Login Timeout IP Address Subnet Mask and Gateway Through the Web Switch Utility you can easily recognize the device by using the System Name and the Location Name The Login Timeout is to set the idle time out for security issue when there is no action in running the Web Switch Utility and the time is up you must re login to Web Switch Utility before you set the Utility Fill up the IP Address Subnet Mask and Gateway for the device The screen in Figure 3 39 appears De PLANET FGSW 4840S 48 4G Ethernet Web Smart Switch System Setting System Name FGSW 48408 AS Location N
11. Address MAC Address Protocol version Product Mame system Mame Loc 192 168 0 1 003041201 5bc 2 001 001 PRSI 45405 i BD view trap Add item Delete item Device Setting Configuration setting Pas word change Firmware Upgrade Web access Exit Figure 3 14 Monitor list screen The Monitor List contains nine items S display the system symbol of the FASW 4840S represent for Switch system is not alive IP Address display the current IP address of the Switch MAC Address display the Switch MAC Address 13 Protocol version display the version of the Utility protocol Product Name display the Switch model name System Name display the appointed Switch system name Location display where the Switch is located Trap IP display the IP address where the Trap to be sent Subnet Mask display the Subnet Mask set of the Switch Gateway display the Gateway set of the Switch View Trap The trap function can receive the events that happen from FGSW 48405 in the Monitor List There is a light indicator behind the View Trap button when the light indicates in green it means that there is no trap received and else when it indicates in red it means that there is new trap received the screen in Figure 3 15 appears Y Web Switch Utility 5 x File View Option Help Discovery List MAC Address IP Address Protocol Version Product Mame System Mame Discovery Add to monitor list als Monito
12. Down 45 Auto Enable Normal Down 39 Auto Enable Normal Down 16 Auto Enable Normal Down 40 Auto Enable Normal Down Paz Auto Enable Normal Down a Auto Enable Normal Down 18 Auto Enable Normal Down 42 Auto Enable Normal Down 19 Auto Enable Normal Down a Auto Enable Normal Down 20 Auto Enable Normal Down 44 Auto Enable Normal Down Par Auto Enable Normal Down 45 Auto Enable Normal Down S Figure 3 26 Port Setting screen Press the port ID to configure each port s speed duplex mode and disable flow control QoS settings The screen in Figure 3 27 appears 19 e PLANET FGSW 48405 48 4G Ethernet Web Smart Switch PORT Settings Please be aware that speed must set as same as link partner VLAN Otherwise packet loss or link error might occur Trunking ay Flow Maintenance ID speed Pew PA 01 Auio x Enable y Nomal y Apply Figure 3 27 Per Port Setting screen The options and descriptions of Port Settings shown as below Speed this function provides six modes 100M Full 100M Half 10M Full 10M Half Auto and Disable When set each port to run at 100M Full 100M Half 10M Full and 10M Half speed modes The note Auto MDIX function will disable Microsoft Internet Explorer T x 2 The speed mode is set to Force mode E The speed mode must be same as the link parnter The Auto MDI Function is disabled cnai Flow C
13. Ethernet Web Smart Switch Factory Reset Setup Fort Please be aware that all configuration will reset to default value Microsoft Internet Explorer x Trunking This browser connection will be disconnected Maintenance Please use default IP address 192 168 0 1 to reconnect to device Status statistics A od o ystem el Backup Setting Reset Seting Logout Figure 3 48 Reset Setting screen 3 1 2 13 Logout Press this function the web interface will go back to login screen The screen in Figure 3 49 appears De PLANET FGSW 4840S 48 4G Ethernet Web Smart Switch Trunking Maintenance Status System Name Location Name IP Address 192 168 0 1 MAC Address 00 30 4f 20 18 bc Password This page is best viewed at 1024x768 with Internet Explorer 5 0 or Netscape 6 0 Figure 3 49 Logout screen 32 4 SWITCH OPERATION 4 1 Address Table The Switch is implemented with an address table This address table composed of many entries Each entry is used to store the address information of some node in network including MAC address port no etc This information comes from the learning process of Ethernet Switch 4 2 Learning When one packet comes in from any port the Switch will record the source address port no And the other related information in address table This information will be used to decide either forwarding or filtering for future packets 4 3 Forwarding amp Filtering
14. FGSW 4840S offers wire speed packet transfer performance without risk of packet loss The high data throughput of these devices make them ideal for most Gigabit environments especially network upgrades to a Gigabit environment The additional Web Switch utility allows access Web interface of FGSW 4840S Smart function such as per port speed duplex flow control and QoS settings Trunking port based VLAN 2 1 1 Product Overview PLANET FGSW 4840S is a Web Smart Gigabit Ethernet Switch with 48 Fast Ethernet ports and 2 Gigabit Ethernet ports support 10 100Mbps and 10 100 1000Mbps Auto Negotiation for optimal speed detection through RJ 45 Category 6 5 or 5e cables Also all the ports support Auto MDI MDI X that can detect the type of connection to any Ethernet device without requiring special straight or crossover cables The FGSW 4840S also provides 2 SFP Mini GBIC interfaces for fiber extension to uplink to a server or a network backbone This products also supports store and forward forwarding scheme to ensure low latency and high data integrity eliminates unnecessary traffic and relieves congestion on critical network paths With an intelligent address recognition algorithm FGSW 4840S could recognize up to 4K different MAC address and enables filtering and forwarding at full wire speed 2 1 2 FGSW 4840S Front Panel Figure 2 1 shows a front panel of FGSW 4840S Y PLANET Me O4870 OMO OO OMO OWO OMPO OMPVO O40 O4VO O4870 OANO OANO OMYVO OMY
15. O0O OMNO OMO 04YO0 O4MYO OFO OsWO O4R70 OVO O4N0 O04N0 51 Mini GBIC 52 Rn msn PASAS AS ASAS AAA A o o FGSW 4840S pee AA A AS AER AE AE OS PAE PA A SAA NA A A Figure 2 1 PLANET FGSW 4840S Front Panel To press and release the RESET button The FGSW 4840S will back to the factory default Note mode Be sure that you backup the current configuration of F SW 4840S else the entire configuration will be erased when pressing the RESET button 2 1 3 LED Indicators System LED Color Function PWR Lights to indicate that the Switch has power SYSTEM Lights and blinking to indicate the CPU is working Per 10 100Mbps port LED Color Function LNK ACT G Lit indicate the link through that port is successfully established 2 Blink indicate that the switch is actively sending or receiving data over that port Per 1000Base T port Color Function LED Lit indicate the link through that port is successfully established LNK ACT Green E e l io Blink indicate that the switch is actively sending or receiving data over that port Green indicate that the port is operating at 1000Mbps REED Green orange reer indicate that the port is operating at 100Mbps Per SFP Mini GBIC port LED Color Function LNK ACT a
16. ability However the switch is most commonly used to segment existing hubs which nearly always improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters Due to the learning function of the Ethernet switching the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Switch performs Store and forward therefore no error packets occur More reliably it reduces the re transmission rate No packet loss will occur 4 5 Auto Negotiation The STP ports on the Switch have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detect the modes and speeds at the second of both device is connected and capable of both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode 1000Base T can be only connected in Full duplex mode 33 3 FROUBLESHOOTING This chapter contains information to help you solve problems If the Switch is not functioning properly make s
17. ame PLANET office SS Trunking Login Timeout Ma ieaAnce 3 30 minutes o IP Address IP address p fies fo fi gt Subnet mask pss ss fs fo Gateway 192 168 fo 258 Apply Figure 3 39 System Setting screen 27 3 1 2 9 Trap The Trap function enables the Switch to monitor the Trap through the Web Switch Utility set the Trap IP Address of the manager workstation where the trap to be sent After setup completed Press Apply button to execute the setting The screen in Figure 3 40 appears D PLANET FGSW 4840S 48 4G Ethernet Web Smart Switch Trap Setting whe Trapp 2 fies fo 57 Trunking Maintenance PEE System Events v device bootup Sere I illegal login 7 IV link up link down iy Fiber e j Port Events abnormal receive error V abnormal transmit error T a Twisted Pair V abnormal receive error setting Port Events V abnormal transmit error Reset Setting Logout Figure 3 40 Trap Setting screen The descriptions of each item is shown as below System Events Monitoring the Switch s trap The options and explanation are shown as following Device Bootup produce a trap when booting up the Switch Illegal Login produce a trap when there is a wrong password login and it will record from which IP login Fiber Port Events monitoring the Switch fiber port status The options and the explanation are shown as following link up link down produce a trap when the fiber link up or link down Ab
18. atus Port Status VLAN Status Trunk Status Press Refresh to renew the posted information The Status screen in Figure 3 36 appears De PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Switch Status _Refiesh VLAK Product Name FGSW 48408 Trunking Firmware Version 1 00 00 Protocol Version 2 001 001 Maintenance ad IP Address 192 168 0 1 Sis Subnet mask 255 255 255 0 Sonis Default gateway 192 168 0 254 Trap IP 0 0 0 0 System Name Login Timeout minutes 5 System UpTime B days 18 hours 29 mins 12 seconds PORT Status 10 100 Mbps Fono Mbps lt CSs lt i iSCSCS ae o op E E w Tiis iii Ea For Auto Enable Nomar Down 25 A Enae Normal Down 02 Auto Enable Normal Down 26 Auto Enable Normal Down 03 auto Enable Normal Down 27 Auto Enable Normal Down a O Ne 3 36 Status screen 3 1 2 7 Statistics The Statistic screen displays the status of packet count from each port Press Refresh to renew the posted information The statistics screen in Figure 3 37 appears De PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Setup Statistics Refresh D TxOk RxOk TxError RxError ID TxOk RxOK TxError RxError nO 10 100 Mbps Maintenance o A o o a AO o ae b Paz 58 76 lo lo System 29 Tap 0 0 Reset Setting Logout LT IN DAMA sae IMENT 0 10 0 O o er PE A aie hz b l b b b b Figure 3
19. d and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Revision PLANET Web Smart Gigabit Ethernet Switch User s Manual FOR MODELS FGSW 4840S Part No EM FGSW4840Sv1 TABLE OF CONTENTS ANTRODUCGTIONS td tadas tatiana 1 a O E A E tare E ners ot arte aie mes ve pei aera as amen Soar ews A pea tee cane eae ER 1 dee ON TO USE TASA UA los i n 1 TS PRODUCT FEATURES A e a odo 1 MA RERSDUCTSPECIECATMONS a e nl o o AAA E EE 2 PANS TALLA TONE a ue 3 221 PRODUCT DES AN a o e terest 3 2 o DS A E A NAAA 3 2 AE a e AE E TA O E E EEA E A E O T EE A ene ia sade T E 3 PA Vee IN E Ba se cree sen E E E TE A N EE E E EE O AS 3 2 1 4 FGSW 46840S Rear A e e Eaa ad e aS 4 22 INSTALLING ARGS VV AC OS as aia 4 2 2 V D
20. e The detail explanation of each item is shown as below View Log to display the events of the FGSW 4840S Clear Log to clear the log of FGSW 48405 a ES File View Option Help View log Clear log E IP Address Protocol wersion Product Mame System Mame Loc Figure 3 10 Web Switch Utility s View screen 3 1 1 1 3 Option In the Option TAB it provides Refresh Time function this function allow user to refresh the monitoring time of Web Switch Utility The available options are 15 secs 30 secs 1 min 2 min and 5 min Y Web Switch Utility Fie View Option Help Disco OMA e 15 secs MAC Address 30 secs Protocol Version Product Name System Mame Loc min 2 mins 5 mins Figure 3 11 Web Switch Utility s Option screen 11 3 1 1 1 4 Help In the Help TAB it provides About function it display the version of the Web Switch Utility og Web Switch Utility ioj x File View Opton Help Discovery List MAC Address IP Address Protocol Version Product Mame System Mame Loc a Web Switch Utility Version 2 02 Protocol Version 2 001 001 Cop might 200 PLANET Technology Corporation OE y Discovery Figure 3 12 Web Switch Utility s Help screen 3 1 1 2 Discovery List This function allows user to list the FGSW 4840S in the entire network By pressing the Discovery button you can list the FGSW 4840S in the discovery list Double click or press the Add
21. e VLAN group Press Delete Group button then the following screen appears 9 PLANET FGSW 4840S 48 4G Ethernet Web Smart Switch VLAN Delete Setup Port ID Description 1D Description VLAN r o Defaut i 02 PLANET Trunking Maintenance Figure 3 33 Delete existence VLAN group screen Press Apply button to execute the setting The following screen in Figure 3 34 appears 23 ote e PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Setup VLAN Setting Ada Grup Delete Group VLAN ID Description a Trunking 01 Defaut 01 02 03 04 05 06 07 08 09 1011121314151617 1819 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Maintenance 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Figure 3 34 Delete existence VLAN group screen The FGSW 4840S supports 26 port based VLAN groups 1 24 and port 25 52 3 1 2 5 Trunking This function provide to cascade two Switch devices with a double bandwidth maximum up to 4000Mbps in full duplex mode There are seven trunk groups and each group provides four selections for fixed trunk port setting Group 1 Group 6 provide Fast Ethernet trunk setting port 1 to port 48 Group 7 for Gigabit Ethernet trunk setting port 49 and port 50 There are four selections in each trunk group and it shown as follow Group 1 Group 2 Group 3 Group 4 Group 5 Selection 1 Disable Selection 2 port 1 2 Selection 3 port 1 2 3 4 Selection 4 port 1
22. esktop IMSTANANOM ex iii 4 2 22 FROCK AVIO UNG fastens A oadialass pandas S 5 S GONFIGUBA T O N te ccicditcc eee tabicut cial sect wilede wi deaviactea viedea wedaae aeaneieweanieuane eas elsc on eaxcnwmemevanteeeetian ves 6 3T PREPARING FOR E ONE UR TN aaa eae 6 31 1 ostall the Web SWitCh Ulead dt id died 6 3 12 Contiqurie me FGoWe4 OS simile 18 AS A ON crt ee E A E NT S A EA EE A niet ae wiee 33 ATMADORESS TAB E a lied e e o O 33 A 2 LEARNING ct A dd 33 AS FORWARDING ALTERNO a a E ol 33 AMES TORES ANDO IA a id aaa 33 AnAUO NO A e ed E 33 5 FROU ESAO O TIN O a a e r a aee 34 VON lad ED D Gy S ee ne AA 35 ATS SWOT SR 24 SPINS ASSIGNMENT S a da 35 A2 1O0 TOOMBES TOMOIBASE TA a A E EEEN 35 AR RJA CABLE PIN ASSIGNMENT o a 35 1 INTRODUCTION 1 1 Package Contents Check the contents of your package for following parts e Web Smart Gigabit Ethernet Switch x1 CD ROM user s manual x1 Quick installation guide x1 e 19 rack mounting kit x1 e Power cord x1 o Rubber feet x 4 If any of these are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us for repair 1 2 How to Use This Manual This 48 10 100Mbps 4G Ethernet Web Smart Switch User Manual is structured as follows Section 2 Installation It explains the functions of FGSW 4840S and how to physicall
23. h the installations of the Web Switch utility 1 Insert the attached user s manual CD in the CD ROM Drive 2 The CD ROM drives to initiate auto run program Once completed The screen in Figure 3 1 appears I GSW 24008 FGSYY 498405 About This CD ROM ECD_GSWib24Sy2 GSW 1600S GSW 24005 The user s manual in PDF format User s Manual Get Adobe Acrobat PDF Reader Web Switch Install Web Switch utility on Windows Utility 98 Me 2000 xKP FGSW 48405 The users manual in PDF format User s Manuel Get Adobe Acrobat PDF Reader Web Switch Install Web Switch utility on Windows Utility 98 Me 2000 xKP Software to help you browse this CD ROM Adobe Acrobat PDF Reader Or to browse this CD ROM click Here PLANET Technology Corp Tel 886 2 2219 9518 Fax 886 2 2219 9528 C it ADs PEretTechroloqyColp Figure 3 1 Web Switch Utility location 3 Press the Web Switch Utility and follow the on screen instructions to install the utility The install procedures in following screens appear 8 Web Switch Utility setup x Welcome to the Installation Wizard This wizard will guide pon through the entire Web Switch Utility installation Welcome to the Web Switch Utility Setup program This program will install web Switch Utility on pour computer Itis strongly recommended that you exit all Windows programe before running thie Setup program Click Cancel to quit Setup and close any programs you have running Cl
24. he Program The Installation Wizard 1s ready to install the Web Switch Utility OU are now ready to install Web Switch Utility Press the Hest button to begin the installation or the Back button to re enter the installation Information host Installer Wizard Back Cancel Figure 3 5 Web Switch Utility install process ma Web switch Utility setup j x Setup Status Please wait Web Switch Utility installation i in progress IF pou want to interrupt installation process press the Cancel button But in this case correct working of the program is not guaranteed Skipping C Program FilessWweb Switch Ublitycto detine ect All tiles Ghost Installer Wizard Cancel Figure 3 6 Web Switch Utility install process ia Web Switch Utility setip Installation Complete The Installation Wizard has successtully installed Web Swatch Utility Web Switch Utility has been successfully installed Press the OF button to exit Setup program Ghost Installer wizard Figure 3 7 Web Switch Utility install completed 4 After install completed choose Program Files gt PLANET Web Switch and execute the Web Switch utility The screen in Figure 3 8 appears e Web Switch Utility z 5 x File View Option Help Discovery List MAC Address IP Address Protocol Version Product Mame System Mame Add to monitor list AF Monitor List IPF Address MAC Address Protocol Version Prod
25. hernet Web Smart Switch Backup Settin Setup 2 Port Please be aware that the device will reboot after config restore successfully VLA Trunking Backup current setting to file Maintenance Tats Restore Statistics Restore saved setting from file i i Browse Backup Reset Setting Logout Figure 3 42 Backup Setting screen 29 Press the Backup button to save the current configuration in manager workstation The following screens in Figure 3 43 amp 3 44 amp 3 45 appear File Download xj You have chosen to download a file from this location config bin from 192 168 0 1 What would you like to do with this file eS Open this file from its current location f Save this file to disk iY Always ask before opening this type of file Cancel More Info Figure 3 43 Backup Setting screen Ax Save in 3 My Documents fe Es Ta My Pictures History Desktop My Documents My eae gc My Network F Save as type bin Document Cancel Z Figure 3 44 Backup Setting screen Download complete 5 x Saved Downloaded 1 38 KE in 1 sec Download to C Documents and Setting contig bin Transfer rate 1 38 BRB Sec 4 Close this dialog box when download completes Open Open Folder 30 Figure 3 45 Backup Setting screen To restore a current configuration file to the FGSW 4840S please specify the backup file and press Restore butto
26. ick Next to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the masimum extent possible under law ghost Installer Wizard Cancel Figure 3 2 Web Switch Utility install process ik Web swaiteh U tility E top Destination Folder Click Nest to install the application to this folder or click Browse to install to a different location Select the destination folder where you want to install web Switch Utility To install to a different location click Browse and select another folder Installation folder C Program Alles Web Switch Utility Browse Ghost Installer wizard Back Cancel Figure 3 3 Web Switch Utility install process Web Switch Utility setup Program Group Select the program group where the Installation Wizard will install application shortouks Select program group PLANET Web Switch ACCESSONes Administrative Tools Adobe Acrobat INFINEON Isla Java 2 Runtime Environment Morton Antivirus Corporate Edition Akad T Sniffer Pro Startup WinZip iedornzoft 5 creenH unter host Installer wizard Back Cancel Figure 3 4 Web Switch Utility install process El Web Switch Utility setup 2 Ready to Install t
27. n to continue after restore completed the FGSW 48405 will reboot for the previous configuration The screen in Figure 3 46 amp 3 47 appears Q PLANET wsie FGSW 4840S 48 4G Ethernet Web Smart Switch Backup Setting Setup Port Please be aware that the device will reboot after config restore successfully Trunking Backup current setting to file Maintenance Stats Restore Statistics Restore saved setting from file e l i CA Documents ang stem Password Backup Setting Reset Setting Browse Logout Figure 3 46 Restore Setting screen Y PLANET FGSW 48405S 48 4G Ethernet Web Smart Switch Backup Settin Setup 5 5 Fort Please be aware that the device will reboot after config restore successfully VLAN Trunking Backup current setting to file Maintenance statis statistics Restore saved setting from file i mps ae E a Microsoft Internet Explorer Z Restore oyster ates ES The browser connection will disconnect ok 1a Please use new IP address to reconnect to device Password X Eackup Setting Cancel Reset Setting Logout Figure 3 47 Restore Setting screen 3 1 2 12 Reset Setting The Factory Reset button can reset the FGSW 4840S back to the factory default mode Be aware that the entire configuration will be reset the IP address of the FGSW 48405S will be set to default setting 192 168 0 1 The screen in Figure 3 48 appears 31 el PLANET FGSW 4840S 48 4G
28. normal Receive Error produce a trap when Switch fiber port receives error data Abnormal Transmit Error produce a trap when Switch fiber port transmits error data Twisted Pair Port Events monitoring the Switch copper port status The options and explanation are shown as following Abnormal Receive Error produce a trap when Switch copper port receives error data Abnormal Transmit Error produce a trap when Switch copper port transmits error data Abnormal 50 error packet count within 10 seconds note 28 3 1 2 10 Password Setting This function provides administrator to secure FGSW 4840S After setup completed Press Apply button to execute the setting The screen in Figure 3 41 appears Q PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Password Setting The maximum length is 20 and is case sensitive TUNKINg M a int enance New Password aca Sta a Re type New Password eae Apply Figure 3 41 Password Setting screen Up to 20 characters is allowed for the password Note After change the default password if you forget the password Please press and release the Reset button in the front panel of FGSW 4840S the current setting includes VLAN will be lost and the FGSW 4840S will restore to the default mode 3 1 2 11 Backup Setting This function allows backup and restore the current configuration of F SW 4840S The screen in Figure 3 42 appears Q PLANET twissi onma FOSW 48408S 48 4G Et
29. o E Enable Normal Down 28 Auto E Enable Normal Down peel Auto aoe Enable cecal aa El a ai nable Normal Down alia Figure 3 25 Web Main screen 3 1 2 3 Port This function allows displaying each port s status The Link Status in the screen displays the current connection speed and duplex mode else this function will show Down when the port is disconnected Press the Refresh button to renew the screen The screen in Figure 3 26 appears e ls PLANET FGSW 48405 48 4G Ethernet Web Smart Switch PORT Setting _Refiesh j 10 100 Mbps VLAN 10100 Mbps ma DEJARA panenane 01 Auto Enable Normal Down 25 Auto Enable Normal Down status o2 lAuto Enable Normal Down 26 Auto Enable Normal Down 04 Auto Enable Normal Down 28 Auto Enable Normal Down 05 Auto Enable Normal Down 29 Auto Enable Normal Down 06 fauto Enable Normal Down 30 Auto Enable Normal Down oz Auto Enable Normal Down 31 Auto Enable Normal Down 08 Auto Enable Normal Down Paz fauto Enable Normal Down 09 fauto Enable Normal Down 33 Auto Enable Normal Down 10 fauto Enable Normal Down 34 Auto Enable Normal Down 11 Auto Enable Normal Down 35 Auto Enable Normal Down EFE Auto Enable Normal Down 36 Auto Enable Normal Down Pa Auto Enable Normal Down Paz Auto Enable Normal Down Pa fauto Enable Normal Down 38 Auto Enable Normal
30. on You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invalidate your warranty Step3 Secure the brackets tightly Step4 Follow the same steps to attach the second bracket to the opposite side Step5 After the brackets are attached to the Switch use suitable screws to securely attach the brackets to the rack as shown in Figure 2 4 44 0088000 Figure 2 4 Mounting the Switch in a Rack Step6 Proceed with the steps 4 and steps 5 of session 2 2 1 Desktop Installation to connect the network cabling and supply power to your Switch 3 CONFIGURATION Unlike the unmanaged switch Dumb switch F SW 4840S performs series smart functions that make the Switch operate more effectively This Chapter will describe the common usage of the Switch s Smart Configuration 3 1 Preparing for configuration When you are ready to configure the smart functions of the Web Smart Gigabit Ethernet Switch Please install the Web Switch utility and it can easily list the F SW 4840S in your Ethernet environment This Web Switch Utility allows assigning an IP address or password change and firmware upgrade for the FGSW 48405 You can easily configure the F SW 4840S s Smart function through the Web browser Such as per port speed duplex flow control QoS settings Trunking and port based VLAN 3 1 1 Install the Web Switch utility The following install instructions guiding you throug
31. ontrol this setting determines whether or not the Switch will be handling flow control Set Flow Control to enable for avoiding data transfer overflow Or it sets to disable there is either no flow control or other hardware software management When the port is set to forced mode then the flow control will automatically set to disable Due to the hardware restriction The flow control function cannot across between port 1 24 note and port 25 52 QoS In some ports that need to have a high priority to deal with the data transfer QoS should be change The default setting of all port QoS is Normal set the QoS to High where the ports have a high priority of transfer data Due to the hardware restriction The QoS control function cannot across between port 1 24 note and port 25 52 3 1 2 4 VLAN This function group individual ports into a small Virtual network of their own to be independent of the other ports The screen in Figure 3 28 appears 20 e PLANET FGSW 48405 48 4G Ethernet Web Smart Switch l VLAN Setting VLAN ID Description Member Trunking 01 Default 01 02 03 04 05 06 07 08091011 121314151617 1819 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 iisintenance m 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Se ERA Delete G Figure 3 28 VLAN Setting screen To add a VLAN group please press Add Group button the new VLAN configuration screen will pop out you can fill in the description in order to
32. orkstation and Choose file dialog box will appear prompting you to select the file to upgrade the firmware Step 2 Please input the correct password and click Start button to start replacing the latest Firmware revision The screen in Figure 3 20 amp 3 21 appears Firmware Upe Eo x Device information Device IP 972 165 0 1 Device MSc 003041201 Dbe Upgrade setting Firmware Path CAsystemFirmwarei6SV17448U H Browse Password z Upgrade State Wait Cancel Figure 3 20 Firmware Upgrade process screen 16 Firmware Upe x Device information Device F 92 165 0 1 je Device Mac 00304f201 Obe Upgrade setting Firmware Path CASystemiFirmwareiGSW17448U H Browse Password asses Upgrade State parade 66 76404 261717 bytes Cancel Figure 3 21 Firmware Upgrade process screen Step 3 After firmware upgrade completed the Switch will reboot automatically Then the following screen in Figure 3 22 amp 3 23 appears Firmware Upgrade x Device information Device IF 192 4 68 01 Device Mac 003047201 Olor Upgrade setting Firmware Path COMINO 174450 AES Browse Password ABRO Upgrade State Complete 261717261717 bytes Start Cancel Figure 3 22 Firmware Upgrade completed screen a 1 Upgrade successful Figure 3 23 Firmware Upgrade successful screen After Switch power on completed Then you can start to use the new firm
33. r List IP Address MAC Address Protocol Version Product Name system Mame 192 168 0 1 003041201 8hc 2 001 001 Fis aas View trap dd item Delete item Device Setting Configuration setting Password change Firmware upgrade Web access Exit Figure 3 15 View Trap screen When clicked the View Trap button the latest Trap Information screen will shown and display the trap information including the Symbol Time Switch IP and the Event occurred The screen in Figure 3 16 appears The symbol a represents the trap signal arise this symbol will disappear after you review and click on the event information 14 Trap information i x s e e Tem 051192004470 192 168 0 1 PFSSsi 45405 4100115 y tem bootup Y 0519 2004 17 0 192 168 0 1 Fiosvy 4o40s 1002 Login invalid password from Clear all Figure 3 16 Trap information screen In order to receive Trap information the FGSW 4840S must configured with Trap IP and Trap Note Events in Web interface Please refer to chapter 3 1 2 9 Trap for detail information Add Item To add a device to the Monitor List manually enter the IP Address of the device that want to monitor Delete Item To delete the device from the Monitor List 3 1 1 4 Device Settings This function contains four items to setting the F SW 4840S Configuration Setting this function allows to assign the IP Address Subnet Mask Gateway and Set Trap to Trap IP Addres
34. s System name and Location Select one device in the Discovery list or Monitor List and press this button then the Configuration Setting screen shown as Figure 3 17 after filling up the data that need to change and fill up the password press the Set button to take effect Configuration setting 7 xj Product name PGS 48405 MAC Address D0304f201 8bc IP Address bo SF 1 Subnet mask 255 joes ee A Gateway 192 168 0 254 Set trap to 192 168 Uy SOF System name Location Fassworg Set Cancel Figure 3 17 Configuration setting screen Password Change this function allows changing the password fill in the password needed in the dialog box and press Set button to take effect The screen in Figure 3 18 appears gg xi New password ES Confirm password essa Original password esses Set Cancel Figure 3 18 Password Change screen Up to 20 characters is allowed for the password note 15 Firmware Upgrade this function allows new firmware upgrade of FGSW 4840S The screen in Figure 3 19 appears Eire are p F xj Device information Device IP 42 166 0 1 q _ _ _ _ ______ _ _ Device Mac 200504201 Dbc Upgrade setting Firmware Fath Browse Password Upgrade State Start Cancel Figure 3 19 Firmware Upgrade screen Firmware upgrade Procedure Step 1 Click Browse button to select the file where you have just saved in your w
35. s select the device in the Monitor List of the Web Switch Utility to settle the device through the Web Browser When the following login screen appears please enter the default password admin and press Login to enter the main screen of FGSW 4840S The login screen in Figure 3 24 appears PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Trunking Maintenance status System Name Location Name IP Address 192 168 0 1 MAC Address 00 30 4f 20 18 bc This page is best viewed at 1024x768 with Internet Explorer 5 0 or Netscape 6 0 Figure 3 24 Login screen 3 1 2 2 Main Menu After entering the password the main screen appears the main screen displays the Switch status The screen in Figure 3 25 appears 18 Q PLANET FGSW 48405 48 4G Ethernet Web Smart Switch Switch Status Refresh Product Name FGSW 48408 atk Firmware Version 100000 Protocol Version 2 001 001 s S IP Address 11 92 168 0 1 Subnet mask 255 255 255 0 Default gateway 11 92 168 0 254 MAC address SS Maintenance Reset Setting Login Timeout minutes l5 System UpTime 3 days 18 hours 29 mins 12 seconds Logout PORT Status 10 100 Mbps i SSS o seca Bra 205 states sooo Bor 005 tate o Auto Enable Normal Down 25 Auto Enable Normal Down 02 Auto Enable Normal Down 26 Auto Enable Normal Down 03 fA Auto E Enable Normal Down 27 A Auto E Enable Normal Down 104 A ut
36. uct Mame System Mame Oy View trap Add tem Delete tem Device Setting ___ ____________ Configuration setting Pas word change Firmware Upgrade Web access Exit Figure 3 8 Web Switch Utility main screen The Web Switch Utility was divided into four parts Toolbar function Discovery List Monitor List Device Setting please refer to the below section for the details instruction 3 1 1 1 Toolbar function The toolbar in the Web Switch Utility provide four main tabs File View Options Help 3 1 1 1 1 File In the File TAB it provides Monitor Save Monitor Save As Monitor Load and Exit item The detail explanation of each item is shown as below Monitor Save to save the current setting of the Monitor List as the Default mode when user access the Web Switch Utility next time it will load the default setting automatically Monitor Save As to save the current setting of the Monitor List in specific filename and file path Monitor Load to load the saved setting file of the Monitor List Exit to exit the Web Switch Utility 10 m Web Switch Utility File Mier Option Help Monitor save Monitor save as Monitor load i IP Address Protocol Version Product Mame System Mame Loc Exit Figure 3 9 Web Switch Utility s File screen 3 1 1 1 2 View In the View TAB it provides view log and clear log function this function will help user to view the trap messag
37. ure the Ethernet Switch was set up according to instructions in this manual The Link LED is not lit Solution Check the cable connection and its quality Some stations cannot talk to other stations located on the other port Solution Please check the VLAN port trunking function that may introduce this kind of problem The address table may contain older information than of the address table of that node Please power down to refresh the address information Performance is bad Solution Check the full duplex status of the partner Switch or device The partner switch is run at full duplex and the Switch runs at Auto Negotiation half duplex mode then the performance will be poor Why the Switch doesn t connect to the network Solution Check the LNK ACT LED on the Switch Try another port on the Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on power again Why the LNK ACT LED of SFP Mini GBIC interfaces is not lit Solution Check the fiber connection Assure use the correct fiber cable for multi mode and single mode Check the port setting of this Switch 34 APPENDIX A A 1 Switch s RJ 45 Pin Assignments 1000Mbps 1000Base T Contact Implicit implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly forbidden is beyond the scope of this standard A 2 10 100Mbps 10 100Base TX
38. ware of FGSW 4840S Web Access Double click the device in the Monitor List or select a device in the Monitor List and press this Web Access button to access the Web interface of FGSW 48405 17 3 1 2 Configure the FGSW 4840S The FGSW 4840S Web Smart Gigabit Ethernet Switch provide Web interface for Switch smart function configuration The FGSW 4840S can be configured through the Web Browser A network administrator can manage and monitor the FGSW 4840S from the local LAN This section indicates how to configure the Switch to enable its smart function The smart functions are shown as below Port Setting Speed duplex mode Disable Flow Control and Port base QoS Virtual LAN Group setting Port based VLAN Trunking System Setting Device status and Statistic Trap and Password 9 A 9090900 Backup Setting 3 1 2 1 Login the Switch Before you start configure the FGSW 48405 please note the FGSW 48405 is configured through an Ethernet connection make sure the manager PC must be set on same the IP subnet address For example the default IP address of the FGSW 4840S is 192 168 0 1 then the manager PC should be set at 192 168 0 x where x is a number between 2 and 254 and the default subnet mask is 255 255 255 0 Use Internet Explorer 5 0 or above Web browser Enter IP address http 192 168 0 1 the factory default IP address to access the Web interface Or through the Web Switch Utility do not need to remember the IP Addres
39. y install the FGSW 48405 B Section 3 Configuration It contains information about the Smart function of FGSW 4840S B Section 4 Switch operation It contains specifications of FGSW 48405 B Section 5 Troubleshooting It contains troubleshooting guide of FGSW 4840S Ss Appendix A It contains cable information of F GSW 4840S In the following section the term Switch means the FGSW 4840S term of switch can be any third part switches 1 3 Product Features Complies with IEEE802 3 10Base T IEEE802 3u 100Base TX and IEEE802 3ab 1000Base T 48 port 10 100Mbps Ethernet ports 2 10 100 1000Mbps ports and 2 SFP mini GBIC interfaces Features Store and Forward mode with wire speed filtering and forwarding rates Hardware based 10 100Mbps half full duplex and 1000Mbps full duplex mode flow control and auto negotiation IEEE802 3x flow control for full duplex operation and backpressure for half duplex operation Integrated address look up engine support 4K absolute MAC addresses Remote Web management interface System log view trap firmware upgrade IP setting through the Web Switch utility Port based VLAN Trunk QoS support Supports backup and restore current configuration Trap function for Switch events Automatic address learning and address aging Supports Auto MDI MDI X function DD WD WD WD WDD WD WD WD WDA WD DD y B Support CSMA CD protocol B 100 240VAC 50 60Hz universal Power input B FCC CE class A compliant

Download Pdf Manuals

image

Related Search

Related Contents

NEC NP-UM330X User's Manual  Utica Boilers TriFire TRB 3 Operation and Installation Manual  Valueline VLVB31903B  Barreira Sense.vp  SAILOR 6110 GMDSS System - Polaris Electronics A/S  XBOX XGX-00038 User's Manual  Sencor SMW 6022 microwave  取扱説明書  Manual - Sagola  

Copyright © All rights reserved.
Failed to retrieve file