Home

Manual - Sagola

image

Contents

1. 49 3 OPERATING PARAMETERS 3 1 Air quality The coalescing filter mounted on the wall SAGOLA Models 5200 or 5300 together with the carbon filter of the equipment s pre set regulator supplies an air quality in accordance with BS 4275 UNE EN 132 if the operating instructions specified in section 9 Maintenance and Service are correctly applied These parameters establish that the air supplied for breathing should not contain excessive impurity in the form of Carbon monoxide 5 ppm 5 5 mg mm3 Carbon dioxide 500 ppm 900 mg mm3 Oil particles 0 5 mg mm3 The air should also be free of odour and contamination Installation of the SAGOLA 5050 pre filter in the compressed air network before the SAGOLA 5200 or 5300 unit is recommended WARNING The SAGOLA 5050 pre filter DOES NOT ELIMINATE CARBON MONOXIDE CARBON DIOXIDE OR OTHER GASES 3 2 Compressed air supply hose The approval of this equipment includes the compressed air supply hoses so it is essential that the equipment be used only with original SAGOLA hoses 3 3 Working and storage temperature The equipment is designed to work in a temperature range of 1 5 to 50 C with a humidity of 80 RH It is recommended that the team be maintained stored in an environment of between 0 and 40 C and a humidity of up to 80 RH in a clean and dry place and preferably covered for example in a plastic bag 3 4 Compressed air pressure The equipment
2. The provision of services during the Guarantee period will not cause this period to be extended as a consequence No gurantee claims shall be acepted for equipament for which SAGOLA has noduly completed guarantee certificate coupon in its files Technical modifications may be made without notice 12 DECLARATION OF CONFORMITY Manufacturer Adress SAGOLA S A Calle Urartea 6 01010 VITORIA GASTEIZ lava SPAIN Hereby declares that the product FACE MASK WITH AIR SUPPLY Brand SAGOLA Model 4240 On the basis of our examination under the requeriment of article 10 of Council Directive 89 686 ECC as amended by council directives 93 68 EEC and 93 95 EEC as recorded in report N 0086 96 0310 For and on behalf the British Standards Institution notifies body Number 0086 The complete technical documentation and service instructions for the product are available in the original version and in the EC languages of users In Vitoria Gasteiz on 01 04 2014 2168 CONDICIONES DE GARANT A GUARANTEE CONDITIONS CONDITIONS DE GARANTIE GARANTIEBENDINGUNGEN CONDICOES DA GARANTIA CONDIZIONI DI GARANZIA Adquirido por Purchased by Acquis par Erworben durch Adquirido por Acquistato da Domicilio Address Adresse Wohnsitz Endere o Indirizzo Poblaci n Town Ville Provincia Province R gion Ortschaft Povoa ao Localit Provinz Provincia Pr
3. ELIMINA EL MONOXIDO DE CARBONO DIOXIDO DE CARBONO U OTROS GASES 3 2 Manguera de suministro de aire comprimido La aprobaci n de este equipo incluye las mangueras de suministro de aire comprimido as pues es indispensable que el equipo sea utilizado solamente con las mangueras originales SAGOLA 3 3 Temperatura de trabajo y almacenamiento El equipo est dise ado para trabajar en un rango de temperatura de 1 5 a 50 C con un grado de humedad del 80 RH Se recomienda que el equipo se mantenga almacenado en un ambiente de entre 0 y 40 C y un grado de humedad de hasta el 80 RH en un lugar limpio seco y preferentemente cubierto por ejemplo dentro de una bolsa pl stica 3 4 Presi n de aire comprimido El equipo est dise ado para trabajar con una presi n de aire comprimido suministrado de entre 4 y 10 bar a la entrada de la manguera La careta requiere un suministro m nimo de 160 l min 5 4 cfm y si se utiliza con una pistola aerogr fica con un minimo de 620 l min 21 cfm suministrados con una presi n de 6 bar 90 psi 3 5 Mangueras de aire La manguera de suministro de aire al regulador pre ajustado debe tener 4 16 Y 8 mm de di metro interior Las longitudes m ximas de la manguera necesarias para mantener un volumen de suministro seguro pueden ser 5 mts a 40 bar 60 psi 7 5 mts a 4 5 bar 70 psi 10 mts a 5 5 bar 80 psi La manguera debe ser de clase no t xica y sin rizo
4. SERVICIO DE GARANT A DE p TECH L NICA REPA VICE PROFFESIONAL REPAR G UARANTEE SERVI SIST STENCIA T REPARACI N pp NCE TECHNIQUE SERVIZI GARANTIE De R PARATION PROFESSIONNELLE Tel 34 945 214 150 TEC ICA ROFESIONAL TECHNIS SCH DIENST PROFESSIONNELLE REPARATURGARAN TE DI ASSISTENZA TECNICA SANZ DI RIPARAZIONE PROFESSIONALE o EE 147 e mail sat sq SK ola
5. St ckliste e This drawing is not the bill of materials e Este desenho n o la lista de materiais Ce sch ma n est pas la liste de materiaux Questo disegno non la distinta base 11 CONDICIONES DE GARANT A Este aparato ha sido fabricado con rigurosa precisi n Habiendo sido sometido a numerosos controles antes de su salida de f brica La GARANT A concedida es de 2 a os a partir de la fecha de compra que ser indicada por e establecimiento vendedor en el lugar habilitado para el respecto junto con su sello Esta GARANT A cubre cualquier defecto de fabricaci n que ser subsanado sin cargo para el comprador Sin embargo quedan expresamente excluidas todas aquellas aver as resultantes de un mal uso de aparato tales como conexiones incorrectas rotura por ca da o similares desgaste normal y en general cualquier deficiencia no imputable a la fabricaci n del aparato As mismo se perder la GARANT A cuando se constate que el aparato ha sido manipulado por personas ajenas a nuestro Servicio de Asistencia T cnica Esta GARANT A no respalda los compromisos adquiridos con cualquier persona ajena al Servicio T cnico Servicio de Asistencia T cnica Tel 34 945 214 150 Fax 34 945 214 147 En caso de aver a durante el periodo de GARANT A adjunte al aparato el justificante del certificado de garant a y entr guelo en el Servicio de Asistencia que m s le interese o bien p ngase en contacto con f br
6. is designed to operate with compressed air pressure supplied at between 4 and 10 bar at the entrance to the hose The mask requires a minimum supply of 160 l min 5 4 cfm and if used with a spray gun with a minimum of 620 l min 21 cfm supplied with a pressure of 6 bar 90 psi 3 5 Air hoses The air supply hose to the pre set regulator should have an internal diameter of 4 16 or Y 8 mm The suggested maximum lengths of hose required to maintain a secure supply volume are 5 mat 4 0 bar 60 psi 7 5 m at 4 5 bar 70 psi 10 m at 5 5 bar 80 psi The hose must be a non toxic type and not curled It must of course be replaced if scratched or marked 4 WARNINGS This equipment is designed for use against contaminants that are not hazardous to life or health where the breathing apparatus is not essential for survival It is possible that with very high work rates the air pressure inside the face mask may become negative momentarily for the user while breathing If this happens contact SAGOLA customer service The equipment is designed for use with compressed air compressed oxygen or enriched oxygen sources should not be used If there is any doubt about the capability of the equipment to carry out the work consult SAGOLA customer service Ifthe supply ceases or is significantly reduced leave the contaminated area and check for possible equipment failure Any modifications made to the equipme
7. of condensation before putting on the equipment The air hose connection for supplying airto the mask is in good condition and is properly connected to the adjustable regulator on the belt The belt is correctly mounted by means of the buckle and is properly tightened the regulator positioned at the hip with the air hose to the visor in front of your body The buckle closes properly The connector of the hose to the spray gun is connected correctly All connections are properly made and that no air leaks 6 3 Checking the air flow NOTE The regulator of the network supply will provide an adequate flow of air to the equipment provided that the length of the air hose is appropriate and the supply pressure to the equipment is as described in section 3 4 The following method should be used to check the flow range to the equipment before entering the work area 1 Connect the compressed air hose to the pre set regulator 2 The flow indicator should be in the section marked in green 3 If the indicator is in any of the areas marked in red Check for and correct any leaks Check and correct the state of the air hose Recheck the indicator 4 If the flow indicator is damaged or stays in the red or green sectors even without air supply replace the indicator before using the equipment 5 If after the second check the indicator is still in any of the red sections the equipment should not be used w
8. the quick and inexpensive change of those parts most susceptible to damage There is a wide range of spare parts and accessories IMPORTANT Before using the mask it is important to read and digest the contents of this instruction manual paying special attention to the warnings characteristics and maintenance requirements indicated as well as the labelling of the model 2 DESCRIPTION OF THE UNIT The equipment is composed of a lightweight mask connected via a breathing tube to a pre set regulator with a flow meter and a carbon filter The regulator is mounted on a belt with an easy to release buckle The equipment is completed with a hose of 10 m for the supply of compressed air from the general air network This hose includes a SAGOLA T 2 connector at one end and at the other end a Y connection with two T 2 couplings There is also a T 2 quick release O male coupling and another hose of 1 5 m with a T 2 connector on one end and a O female nut to connect to a spray gun Technical specifications Nominal protection factor 220 Air pressure Maximum 10 bar 145 psi Recommended 4 bar 60 psi Maximum length of supply hose to the regulator 15 mts Pressure range to the face mask Maximum 232 l min Recommended 160 I min Temperature of the work environment 1 5 to 50 C Working life of the carbon filter 400 hours approximately 2 months Impact protection of the visor EN 166 F for visors
9. Rr EN laal T N manual de instrucciones lista de repuestos instruction manual spare parts list ndice 1 Introducci n 2 Descripci n del Equipo 3 Par metros de operaci n 3 1 Calidad del aire 3 2 Manguera de suministro de aire comprimido 3 3 Temperatura de trabajo y almacenamiento 3 4 Presi n de aire comprimido 3 5 Mangueras de aire 4 Advertencias 5 Chequeo del rea de trabajo 6 Instrucciones de uso 6 1 Ala recepci n del equipo 6 2 Antes del empleo del equipo 6 3 Comprobaci n del caudal de aire 7 Montaje del equipo 8 Mantenimiento General 9 Mantenimiento y Servicio 9 1 Regulador pre ajustado 9 2 Unidad de filtraje en cintur n e indicador de caudal 9 3 Productos de limpieza recomendados 10 Despiece 11 Garant a 12 Declaraci n de Conformidad p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g p g o oon NN NNN DW DDO Oo na aaa a A A 1 INTRODUCCI N Muchas gracias por haber adquirido un producto SAGOLA Nos alegramos de haber encontrado un cliente en Usted Los productos SAGOLA re nen los m s elevados avances t cnicos de dise o y de facilidad de manejo Aplicamos los m s estrictos requisitos de calidad a todos nuestros productos para satisfacer las expectativas m s exigentes ADVERTENCIAS DE SEGURIDAD a Dise o para la utilizaci n _ La careta 4240 NO ESTA DISE ADA para su e
10. ance Components damaged by use must be replaced The parts of them are indicated in the graph corresponding spare parts 9 1 Pre set regulator This component is pre set and sealed in accordance with the established regulatory requirements It can only be replaced by another that is identical 9 2 Filter unit on waist belt and flow indicator The unit has a removable vessel where the carbon canister is housed which must be replaced with the compressed air supply disconnected if its colour changes from white to pink or an unusual smell is noticed in the mask It is also suggested that the filter is periodically subjected to a test of differential pressure at full flow and if a level of 0 7 bar 10 psi is reached the filter must be replaced The filter is replaced by releasing the vessel unscrewing the filter and then proceeding in reverse order with the replacement filter The vessel should be washed with soapy water and then dried Replace it if it shows any signs of deterioration or discolouration Mount ensuring that there are no leaks 9 3 Recommended cleaning products Solution of water with neutral soap Disinfectant Antistatic cloth for the visor of the mask 10 DETAIL DRAWING 15880011 15880012 15880009 15880014 15880015 56414033 03 15880013 15880010 e This drawing is not the bill of m H 02 HYGIENE KIT 5u 11 WARRANTY CONDITIONS This guarant
11. ea de equipos de aire comprimido con una variedad de piezas para la cabeza a utilizar en aplicaciones tales como pintura pulverizada o contra polvo t xico niebla o humos es decir en situaciones en las que un equipo de respiraci n no es imprescindible para sobrevivir El equipo ha sido probado aprobado y certificado por BS EN270 Formely HSE Testing Memorandum 14 7 25 issue 7 factor de protecci n 200 Sus principales componentes est n dise ados para ofrecer la m xima duraci n y un r pido y econ mico cambio de estas piezas m s susceptibles de estropearse Existe una amplia gama de piezas de recambio y accesorios IMPORTANTE Antes de utilizar la careta es importante leer y asimilar el contenido de este manual de Instrucciones prestar especial atenci n a las advertencias caracter sticas y requerimientos de mantenimiento indicados as como al etiquetado del modelo 2 DESCRIPCI N DEL EQUIPO El equipo est compuesto por una careta de bajo peso conectada a trav s de un tubo de respiraci n a un regulador pre ajustado con indicador de caudal y un filtro de carbono El regulador est montado en un cintur n con una hebilla que se suelta f cilmente El Equipo se completa con una manguera de 10 mts para el suministro del aire comprimido desde la red general de aire Esta manguera que incorpora en un extremo un conector SAGOLA T 2 en un extremo y un una conexi n en Y con dos Enchufes T 2 Tambi n
12. ee has been manufactured with strict precision an d has been subjected to a large number of controls before it left the factory The GUARANTEE is for 2 years counted as of the date of purchase which will be indicated by the establishment where the apparatus is purchased in the place provided for this purpose together with its stamp The GUARANTEE covers all nanufacturind defects which will be repaired free of charge Nevertheless all those malfunctions which are the result of the incorrect use of the apparatus such as incorrect connections breakage due to the apparatus being dropped or similar normal wear and tear and in general any deficiency not attributable to manufacture Likewise the GUARANTEE will became invalid should be abserved that the apparatus has been handled by persons other than our Technical Service personnel This GUARANTEE does not support any commitment made by any person other than our Technical Service personnel Technical Service Personnel Tel 34 945 214 150 Fax 34 945 214 147 In the case of any malfunction during the peiod of GUARANTEE enclose the guarantee certificate with the apparatus and deliver it to the nearest Technical Service or get in contact with the factory Any other claims against the supplier beyond those expressed above are excluded especially regarding indemnification for damages This is equallu applicable to damages arising during consultation trainingand demostration
13. ica Queda excluida cualquier exigencia de m s trascendencia contra el proveedor en particular la indemnizaci n por da os y prejuicios Esto se aplica igualmente a los da os que se originasen durante el asesoramiento la adquisici n de pr ctica y la demostraci n Las prestaciones por garant a no tienen por consecuencia una prolongaci n del periodo de la misma No se atender en garant a ning n equipo del cual no conste en los archivos de SAGOLA el resguardo adjunto del certificado de garant a debidamente cumplimentado Reservadas la modificaciones T cnicas 12 DECLARACI N DE CONFORMIDAD Fabricante SAGOLA S A Direcci n Calle Urartea 6 01010 VITORIA GASTEIZ lava ESPA A Declaramos que el producto CARETA CON SUMINISTRO DE AIRE Marca SAGOLA Modelo 4240 Sobre la base de nuestro examen en virtud de los Requerimientos del art culo 10 de la Directiva del Consejo 89 686 ECC en su versi n modificada por las Directivas 93 68 CEE y 93 95 CEE seg n consta en el informe N 0086 96 0310 Por y en nombre de la British Standards Institution notifica N mero cuerpo de 0086 Se encuentran disponibles la documentaci n t cnica completa y las instrucciones de servicio del producto en la versi n original as como en los idiomas comunitarios de los usuarios En Vitoria Gasteiz a 01 04 2014 Mur Index 1 Introduction 2 Description of the Equipment 3 Operating Parameters 3 1 Air qua
14. ithout a thorough examination of its condition and a new checking process 7 ASSEMBLY OF THE EQUIPMENT NOTE Only when the equipment is fitted correctly as described below will it provide the prescribed degree of protection 1 Put the belt to support the regulator around your waist positioning the regulator above the right hip 2 Place the mask on your head adjusting it to your head to achieve the most comfortable and efficient position for working Remove any trace of condensation before putting on the mask 3 Connect the air supply hose from the regulator to the mask If you notice vibrations during the connection disconnect and then reconnect 4 If applicable attach the air supply hose to the spray gun 5 While walking make sure the hoses do not become entangled with each other and impede your movement 8 GENERAL MAINTENANCE The equipment requires a monthly check up Care of the equipment during and after its use will ensure a reliable and lasting service After use the equipment should be washed with water and a solution of neutral soap then rinsed with a damp cloth and dried To keep the mask in the best possible condition do not use abrasive cleaning products Rinse with water and mild detergent and dry with a soft cloth Do not use solvents or abrasive cleaning agents These will damage the equipment See section 9 3 s q4 9 MAINTENANCE AND SERVICE The equipment requires minimal mainten
15. lity 3 2 Compressed air supply hose 3 3 Working and storage temperature 3 4 Compressed air pressure 3 5 Air hoses 4 Warnings 5 Work area check 6 Instructions for use 6 1 On receipt of the equipment 6 2 Before using the equipment 6 3 Checking the air flow 7 Assembly of the equipment 8 General maintenance 9 Maintenance and Service 9 1 Pre set regulator 9 2 Filter unit on waist belt and flow indicator 9 3 Recommended cleaning products 10 Detail drawing 11 Guarantee 12 Conformity declaration page 12 page 12 page 13 page 13 page 13 page 13 page 13 page 13 page 13 page 14 page 14 page 14 page 14 page 14 page 14 page 14 page 15 page 15 page 15 page 15 page 15 page 16 page 16 1 INTRODUCTION Thank you very much for purchasing a SAGOLA product We are pleased to have you as a customer SAGOLA products combine the very latest technical developments with the highest levels of design and ease of use We apply the most stringent quality controls to all of our products in order to meet the most demanding requirements SAFETY WARNINGS a Design for use The 4240 face mask IS NOT DESIGNED for use in environments containing flammable gases This model is designed for use against contaminants that are not hazardous to life or health and where the breathing apparatus is not essential for survival The model 4240 is designed for use with compressed air compressed or enriched oxygen sources should not be u
16. mpleo en ambientes con presencia de gases inflamables Este modelo est dise ado para su empleo contra contaminantes no peligrosos para la vida O la salud o donde el aparato de respiraci n no es indispensable para sobrevivir El modelo 4240 est dise ado para su empleo con aire comprimido las fuentes de aire de ox geno comprimido o enriquecido no deben ser utilizadas No se asegura protecci n alguna si la careta no est colocada correctamente o no se mantiene un adecuado suministro de aire respirable Solamente se asegura el grado de protecci n prescrito cuando el equipo est colocado correctamente La combinaci n de un filtro SAGOLA 5200 0 5300 instalado en la pared con el filtro de carbono montado en el cintur n del equipo no elimina el mon xido de carbono ni el di xido de carbono u otros gases t xicos b Presi n negativa Es posible que a ndices de trabajo muy altos el aire comprimido dentro de la careta pueda resultar negativo durante la respiraci n Este equipo tiene un caudal m ximo de 232 litros minuto y no debiera ser utilizado para trabajos en los que se requiera mayor caudal que el citado c Suministro de aire comprimido El usuario debe asegurarse de que el rango de presi n del aire que llega al equipo est dentro de los l mites recomendados Si el suministro de aire cesa o se reduce significativamente debe abandonar la zona contaminada y comprobar los posibles fallos en el equipo L n
17. nt or replacement of any components with others that are not original may reduce the protection provided to the user and invalidate the HSE protection and guarantees provided by the manufacturer 5 WORK AREA CHECK 1 It is possible to measure the pressure of the air supplied 2 From the general compressed air network the air will arrive at the equipment at the proper air pressure Section 3 4 3 The air that arrives will be within the standard of breathability 4 The air hose is long enough for the user of the equipment to work without having to take off the equipment 2 43 e 6 INSTRUCTIONS FOR USE 6 1 On receipt of the equipment check that The equipment is complete according to the specification of its composition The equipment has not been damaged in transit 6 2 Before each use check that The equipment is complete according to the specification of its composition The coalescing filter of the air network is usable The air hoses are in good condition have leak free connections and are sufficiently well adjusted The regulator and carbon filter are clean and show no signs of changing colour from white to pink and there are no symptoms of smell in the mask Change if necessary Thatthe pads and components for adjusting to the face are clean and have no signs of deterioration or damage If the equipment has been stored in a cold environment avoid the appearance of signs
18. ntro de los standar de respirabilidad 4 Que la manguera de aire sea lo suficientemente larga para que el usuario del equipo pueda trabajar sin necesidad de desprenderse del equipo 6 INSTRUCCIONES DE USO 6 1 A la recepci n del equipo compruebe Que el equipo est completo de acuerdo con lo indicado en su composici n Que el equipo no ha resultado da ado en el transporte 6 2 Antes de cada utilizaci n compruebe Que el equipo est completo de acuerdo con lo indicado en su composici n Que el filtro coalescente de la Red de aire est utilizable Que las mangueras de aire est n en buenas condiciones y sus conexiones sin fugas y suficientemente bien ajustadas Que el regulador y el filtro de carbono est n limpios y no muestran signos de cambio de color de blanco a rosa y que no hay s ntomas de olor en la careta Cambiar si fuese necesario Que las almohadillas y elementos de ajuste a la cara est n limpios y no tienen signos de deterioro o da o Si el equipo ha sido almacenado en un ambiente fr o evite la aparici n de signos de condensaci n antes de colocarse el equipo Que la manguera de conexi n de aire a la careta est en buenas condiciones correctamente conectada al regulador ajustable del cintur n Que el cintur n est correctamente montado a trav s de la hebilla y ce ido posicione el regulador en la cadera con la manguera de aire al visor por delante de su cuer
19. ovincia CR PC CR Pa s Country Pays PLZ CP CAP Land Pais Paese Tel Fax Vendido por Sold by Vendu par Verkauft durch Vendido por Venduto da Tel Fax Modelo Model Modele N de equipo Equipment no No de l appareil Modell Modelo Modello Ger te Nr Kp de equipa N attrezzatura Sello Stamp Cachet Stempel Selo Timbro Fecha de compra Date of purchase Date d achat Kaufdatum Data de Compra Data di aacquisto CONDICIONES DE GARANT A GUARANTEE CONDITIONS CONDITIONS DE GARANTIE GARANTIEBENDINGUNGEN CONDICOES DA GARANTIA CONDIZIONI DI GARANZIA Adquirido por Purchased by Acquis par Erworben durch Adquirido por Acquistato da Domicilio Address Adresse Wohnsitz Endere o Indirizzo Poblaci n Town Ville Provincia Province R gion Ortschaft Povoa ao Localit Provinz Provincia Provincia CP PC CR Pa s Country Pays PLZ CP CAP land Pa s Paese Tel Fax E mail Vendido por Sold by Vendu par Verkauft durch Vendido por Venduto da Tel Fax Modelo Model Modele N de equipo Equipment no No de l appareil Modell Modelo Modello Ger te Nr N de equipa N attrezzatura Sello Stamp Cachet Stempel Selo Timbro Fecha de compra Date of purchase Date d achat Kaufdatum Data de Compra Data di aacquisto SA cong
20. po Que la hebilla cierra correctamente Que el conector de la manguera a la pistola aerogr fica est correctamente conectado Compruebe que todas las conexiones est n correctamente hechas y que no hay fugas de aire 6 3 Comprobaci n del caudal de aire NOTA El regulador de la red aportar un caudal de aire al equipo adecuado siempre que la longitud de la manguera de aire sea la apropiada y el suministro de presi n al equipo el descrito en el apartado 3 4 Deber utilizarse el m todo siguiente para comprobar el rango de caudal al equipo antes de entrar en el rea de trabajo 1 Conecte la manguera de aire comprimido al regulador pre ajustado 2 El indicador de caudal debe estar en la secci n marcada en color verde 3 Si el indicador est en cualquier de las zonas marcadas en color rojo l Verifique y corrija la existencia de fugas Verifique y corrija el estado de la manguera de aire Vuelva a verificar el indicador 4 Si el indicador de caudal est da ado o se mantiene en los sectores rojo o verde aun sin suministro de aire reemplace el indicador antes de utilizar el equipo 5 Si despu s de la segunda verificaci n el indicador est aun en cualquiera de las secciones rojas el equipo no debe ser utilizado sin que se realice un completo examen de su estado y de una nueva verificaci n 7 MONTAJE DEL EQUIPO NOTA Solamente cuando el equipo est colocado correctamente como
21. s Por supuesto deber ser sustituida si se raya o marca 4 ADVERTENCIAS Este equipo est dise ado para ser utilizado contra contaminantes que no sean peligrosos para la vida y la salud lugares donde el aparato de respiraci n no sea indispensable para sobrevivir Es posible que con ndices de trabajo muy altos la presi n de aire dentro de la careta pueda ser momentaneamente negativa para el usuario mientras respira Si esto sucede consulte con el servicio de atenci n al cliente de SAGOLA El equipo esta dise ado para su uso con aire comprimido no se deben emplear fuentes de aire de ox geno comprimido u ox geno enriquecido Si hubiese alguna duda sobre la disponibilidad del equipo para trabajar consulte con el servicio de atenci n al cliente de SAGOLA Si el suministro cesa o se reduce significativamente abandone la zona contaminada y revise la existencia de posibles fallos en el equipo Cualquier modificacion realizada en el equipo O la sustituci n de alguno de sus componentes por otros no originales puede reducir la proteccion proporcionada al usuario e invalidar la proteccion HSE y garant as dadas por el fabricante 5 CHEQUEO DEL REA DE TRABAJO Antes de iniciar el trabajo compruebe que 1 Es posible medir la presi n de aire suministrada 2 Que desde la red general de aire comprimido llegar al equipo aire a la presi n adecuada Apartado 3 4 3 Que el aire que llegar estar de
22. s deben ser sustituidos Los repuestos de los mismos se indican en el gr fico de despiece correspondiente 9 1 Regulador pre ajustado Este componente est pre ajustado y sellado de acuerdo con los requerimientos normativos establecidos Solo puede ser reemplazado por otro igual 9 2 Unidad de filtraje montada en el cintur n e indicador de caudal La unidad tiene un vaso desmontable en el que se aloja el cartucho de carb n que con el suministro de aire comprimido desconectado debe ser sustituido si su color cambia de blanco a rosa o en la careta ser percibe alg n olor extra o Tambi n se sugiere que el filtro sea peri dicamente sometido a un examen de presi n diferencial a pleno caudal si se alcanza un nivel de 0 7 bar 10 psi el filtro debe ser sustituido El filtro se sustituye soltando el vaso desenroscando el filtro y procediendo en sentido contrario con su sustituto El vaso debe ser lavado con agua jabonosa y secado posteriormente Si presenta alg n tipo de deterioro o decoloraci n sustit yalo M ntelo asegur ndose de la inexistencia de fugas 9 3 Productos de limpieza recomendados Soluci n de agua con jab n neutro Desinfectante Pa o antiest tico para el visor de la careta 10 DESPIECE 02 HYGIENE KIT 5u 15880011 15880012 15880013 15880009 15880014 15880015 56414033 15880010 e Este dibujo no es la lista de materiales Diese Zeichnung ist nicht die
23. se describe a continuaci n ofrecer el grado de protecci n prescrito 1 Monte el cintur n de soporte del regulador a su cintura posicionando el regulador por encima de la cadera derecha 2 Coloque la careta en su cabeza ajust ndola a su cabeza para mantener la posici n m s c moda y eficiente para la realizaci n del trabajo Elimine todo resto de condensaci n antes de colocarse la careta 3 Conecte la manguera de suministro de aire del regulador a la careta Si percibe vibraciones durante la conexi n desconecte y conecte nuevamente 4 Conecte si procede la manguera de suministro de aire a la pistola aerografica 5 Mientras camine aseg rese de que las mangueras no se enredan entre s y dificultan su desplazamiento 8 MANTENIMIENTO GENERAL El equipo requiere de una revisi n mensual El cuidado durante y despu s de su empleo garantiza un servicio fiable y duradero Despu s de su utilizaci n el equipo debe ser lavado con agua y una soluci n de jab n neutro enjuagado con un trapo h medo y secado Para mantener la careta en las mejores condiciones posibles no emplee en su limpieza productos abrasivos Acl rela con agua y un detergente suave y s quelo con un trapo suave No utilice disolventes o agentes abrasivos de limpieza Da ar n el equipo Ver apartado 9 3 9 MANTENIMIENTO Y SERVICIO El equipo requiere de un m nimo mantenimiento Los componentes deteriorados por el uso o da ado
24. sed No protection at all is guaranteed if the mask is not fitted correctly or an adequate supply of breathable air is not maintained The prescribed degree of protection is only ensured when the equipment is correctly fitted The combination of a SAGOLA 5200 or 5300 filter mounted on the wall with the carbon filter mounted on the waist belt of the equipment does not eliminate carbon monoxide carbon dioxide or other toxic gases b Negative pressure It is possible that at very high work rates the compressed air pressure inside the mask could become negative during breathing This equipment has a maximum flow rate of 232 litres minute and should not be used for jobs requiring a flow rate greater than this c Compressed air supply The user must ensure that the range of air pressures reaching the equipment is within the recommended limits If the air supply ceases or is significantly reduced the user must leave the contaminated area and check the possible failures in the equipment This is a line of compressed air equipment with a variety of parts for the head and for use in applications such as spray painting or against toxic dust mist or fumes i e in situations where a breathing apparatus is not essential for survival The equipment has been tested approved and certified according to BS EN270 formerly HSE Testing Memorandum 14 7 25 issue 7 protection factor 200 Its main components are designed for maximum durability and
25. un Enchufe r pido T 2 de D M y otra manguera de 1 5 mts con conector T 2 en un extremo y tuerca de D H para conectar a una pistola aerogr fica Especificaciones T cnicas Factor nominal de protecci n 220 Presi n de aire M xima 10 bar 145 psi Recomendada 4 bar 60 psi Longitud m xima de la manguera de suministro al regulador 15 mts Rango de presi n a la careta M xima 232 l min Recomendada 160 l min Temperatura del ambiente de trabajo 1 5 a 50 C Duraci n del filtro de carbono 400 horas de trabajo Aproximadamente 2 meses Protecci n contra impactos del visor EN 166 F para visor H ee 3 PAR METROS DE OPERACI N 3 1 Calidad del aire El filtro coalescente montado en la pared Modelos SAGOLA 5200 5300 en conjunto con el filtro de carbono del regulador pre ajustado del equipo aportan una calidad de aire BS 4275 prEN 132 si se aplican correctamente las instrucciones de servicio indicadas en el apartado 9 de Mantenimiento y Servicio Estos par metros establecen que el aire suministrado para la respiraci n no debiera contener impureza en exceso de Mon xido de carbono 5 ppm 5 5 mg mm3 Di xido de carbono 500 ppm 900 mg mm3 Part culas de aceite 0 5 mg mm3 El aire deber a estar libre tambi n de olor y contaminaci n Se recomienda instalar en la red previamente al equipo SAGOLA 5200 0 5300 el pre filtro SAGOLA 5050 ADVERTENCIA Este pre filtro SAGOLA 5050 NO

Download Pdf Manuals

image

Related Search

Related Contents

CV17-CV25, CV620-CV730, CV740, CV750 Manual de servicio  FRÉDÉRIC  UM - EN - REV 0.X3 - User Manual AVANTGARDE  OPERATING INSTRUCTIONS  AGNEAU SOLUBLE La présure d`agneau soluble en pâte s`utilise  Samsung PS-50P5H Manual de Usuario  HERMA Adress labels A4 99.1x33.8 mm natural-white recycled paper matt blue angel 1600 pcs.  SOLA II Flare - Thermo Scientific  ベルト式無段変速機  Owner/Operator Manual  