Home
AJ65FBTA2-16T CC-Link System Low Profile Waterproof Type
Contents
1. to damage of the screws WIRING PRECAUTIONS Completely turn off the externally supplied power used in the system when installing or placing wiring Not completely turning off all power could result in electric shock or damage to the product CAUTION Be sure to ground the FG terminals to the protective ground conductor Not doing so could result in electric shock or erroneous operation When wiring in the PLC be sure that it is done correctly by checking the product s rated voltage and the terminal layout Fix the attachment screws of waterproof cap and communication adapter securely within the specified torque range Loose attachment screws may cause a fire or erroneous operation If the attachment screws are too tight it may cause a short circuit or erroneous operation due to damage of the screws Make sure that foreign objects do not get in side the module such as dirt and wire chips It may cause fire product failure or malfunction IP67 is only satisfied when the waterproof plug waterproof cap and communication adapter are all connected Do not attach the communication cable to the I O connector as the I O connector the communication connector and the power supply connector are the same in shape Failure to do so may cause frailer or malfunction of the PLC WIRING PRECAUTIONS CAUTION Be sure to fix the wires or cables by ducts or clamps when connecting them to the module Failure to do so may cau
2. touch the grounded metal to discharge the electricity charged in the electricity charged in the body etc before touching the module Failure to do say cause a failure or malfunctions of the module DISPOSAL PRECAUTIONS CAUTION When disposing of this product treat it as industrial waste 0706 MEE 1 Specification E vein Bal Overload protection function overheat protection Protect function function OFF ON 0 5 ms or lower R i OFF gt ON _ PE ON OFF 1 5 ms or lower resistive load External power Voltage 10 2 to 28 8 V DC ripple ratio within 5 supply for output Curent 20 mA or lower when 24 V DC all points ON part Not including external load current Surge suppressor a 16 points 1 common Wiring method for common waterproof connector 2 wire type Number of stations occupied 1 station 32 points assignment use 16 points I O module power Voltage 20 4 to 26 4 V DC ripple ratio within 5 supply Current 50 mA or lower when 24 V DC all points ON DC type noise voltage 500 Vp p noise width 1 us Noise durability noise frequency 25 to 60 Hz noise simulator condition 500 V AC for 1 minute between all DC external Withstand voltage terminals and ground 10 Ma or higher measured with a 500 V DC Insulation resistance insulation resistance tester between all DC external terminals and ground Protection of degree IP67 Weight 0 40 kg Waterproof cap ASCAP WP2 For informat
3. O lt 0 0 I O connector Load power 3 jel lt m jei lt N D lt SK WO m m 3 lt 3 xN INJ jvjsS Z Z lt s5 Col lafajo r slajale r sjalale yislalalo n a D lt ajs jely gt jajs jelin gt an S D lt m lt lt gt 3 52 g o 3 5 lt K Sle lt UO ols m 3 lt E 3 O iz a A j 65 Tl m x 3 lt N DJS N F 2 lt ms mm m Empty 9 Screw hole for module attachment 2 4 5 X 6 length hole 10 jattachment M4 attachment screw Tightening torque range 78 to 118 N cm hole 1 Duplicate station number cannot be set 2 Waterproof connector based on IEC947 5 2 M12 type
4. aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN IB 0800196 D AJ65FBTA2 16T U AJ65FBTA2 16T CC Link System Low Profile Waterproof Type Remote I O Module User s Manual e SAFETY PRECAUTIONS Read these precautions before using When using this equipment thoroughly read this manual Also pay careful attention to safety and handle the module properly These precautions apply only to this equipment Refer to the CPU module user s manual for a description of the PC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories DANGER and CAUTION Procedures which may lead to a dangerous condition and lt PDANGER cause death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and CAUTION cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by A CAUTION may also result in to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS When a communication error occurs in the data link the communication error station will be in the following condition Configure an interlocking circuit in a sequence prog
5. cn ON__ OFF _ 1100 resistor ON N No 1300 resistor ON AY Setting prohibited v9 When shipped from the factory all settings are set to OFF Y9 Sik f Contents YB Connector for connecting the transmission Waterproof LINK line from the IN side master station side Male 4 pins connector for transmission Connector for connecting the transmission line 2 line from the OUT side Be sure to attach LINK the waterproof cap when not in use YA Female 5 pins Tightening torque range 29 to 34 N cm Yb Sik f Contents Waterproof Connector for supplying power to the connector for TEES module Male 5 pins vee power line 2 Connector for supplying power to a load al etc Male 5 pins Waterproof connecior tor Waterproof connector for connection output signal Female 5 pins input Be sure to attach waterproof cap AGCAP WP2 sold separately when ney not in use Tightening torque range 29 to 34 N cm connection 2 8 FG metal fitting For module FG terminal tightening torque range 78 to 118 N cm Communication When replacing the main body online or changing switch setting adapter fixing attach remove the communication adapter with this screw Tightening torque range 42 to 58 N cm Insulation UNIT POWER 1 D K AUX A A e ah doe N D lt FF D 3 0 ON E Costant voltage circuit K o 3 5 lt As lt e 00 m 3 5 lt 5 o
6. ion about the connection devices necessary to use the main module see the CC Link System Small Type Remote I O Module User s Manual Printed in Japan on recycled paper e 2 4 5x 6 mounting screw Connector for connection to main module 60 0 2 36 48 1 89 NE 34 0 5 1 33 18 3 0 72 mol lt A SNe Communication adapter back Communication adapter front Connector for connection to communication adapter 3 f WITSUBISHI MELSHC AJ65FBTA2 16T 3 Pe i 8 10 Pal N za 1 Main module TEA A Communication STATION NO 6 6 adapter x co N ost Ke oe he 2 Name and Setting of Each Area Sia d Description ON ie Confirmation details 2 i POWER JON Power supply ON OFF Power supply OFF iD L RUN ON Normal communication N i OFF Communication shut off time expiration error an D i LO i N i a 0 2 Ye N ON Communication data error 7 Flash at regular intervals i Indicates that the station number setting or status indicator transmission speed setting switch position was L ERR changed while power is ON Storage l Flash at irregular intervals When the setting of the terminal resistor is wrong sheet when the cable for the module or CC Link is i affected by noise OFF Normal communication ni ON Output ON OFF Output OFF 4 1 0 16 im M4 mounting screw 7 0 g value Tran
7. ram using the communication status information so that the safety of the overall system is always maintained Accident may occur due to output error or malfunction 1 Input points from remote I O station will be all switched off 2 Output points from remote I O station will be all switched off Output could be switched on or off when a problem occurs in the remote I O modules So build an external monitoring circuit that will monitor any output signals that could cause a serious accident CAUTION Use each module in an environment as specified in the general specification in the CPU module user s manual Usage of the module outside the general specification range may cause electric shock fire malfunction product damage or deterioration Do not have control cables and communication cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference INSTALLATION PRECAUTIONS CAUTION Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module Tighten the module securely using DIN rail or installation screws within the specified torque range Loose terminal screws may cause a short circuit or erroneous operation If the terminal screws are too tight it may cause falling short circuit or erroneous operation due
8. se damage of the module or the cables due to accidental pull or unintentional shifting of the cables or malfunctions due to poor contact of the cable Do not install the control lines together with the communication cables or bring them close to each other Failure to do so may cause malfunctions due to noise When disconnecting a communication or power supply cable from the module do not pull on the cable itself Disconnect cables not fitted with a connectors by holding and pulling the cable connector Disconnect cables not fitted with a connector by removing the screws from the part connected to the module can cause damage to the module or cable or malfunction due to cable connection faults STARTING AND MAINTENANCE PRECAUTIONS lt SDANGER Do not touch terminals when the power is on Doing so could cause an electric shock Switch off all phases of the externally supplied power used in the system when cleaning the module or retightening the terminal or module mounting screws Not doing so could result in electric shock CAUTION Never try to disassemble of modify module It may cause product failure malfunction fire or cause injury Do not drop or apply any strong impact to the module Doing so may damage the module Completely turn off the externally supplied power used in the system before mounting or removing the module to from the panel Not doing so could result in damage to the product Always make sure to
9. smission speed 35 1 37 TO OFF OFF OFF 156kbps i 1 OFF OFF ON 625kbps Transmission speed seting Be sure to set the transmission speed within the above range Communication connector Remove the communication adapter on the top part of the module to Pin LINKIN LINK OUT set the transmission speed When shipped from the factory all settings are set to OFF External connection Z O Select 10 20 or 40 to set the tens place of the station number 3 Select 1 2 4 or 8 to set the ones place of the station number Always set the station number within the range of 1 to 64 1 LINK IN ao E COON Ect r CTO Example Set the switches as below when setting the station number J Communication to 32 moe s circuit Empty Station number Station Tens place Ones place setting switch number 40 20 10 8 4 2 i gt eR LINK OUT R A 4 OK Hd Pin UNIT OOOOH SET Terminal AUX o OWER 7 Remove the communication adapter on the top part of the module to G v select switch 5 g 24V 1 0 set the station number When shipped from the factory all settings are Empty setto OFF 24G UNIT 24G I O The terminal resistor can be turned to the ON setting by using the select w o ea Empty switch m B FG DIP switch DIP switch 2 OF Terminal 4 I O connector No terminal resistance rm Pin Signal Pin Signal Sosane