Home

EN User Manual

image

Contents

1. 5 aa a ja ja 5 ELECTRICAL CONNECTION 2 a i a 6 START UP AND OPERATION a i ai si 7 MAINTENANCE AND CLEANING 7 TAKING THE UNIT OUT OF OPERATION FOR EXTENDED PERIODS 9 DISPOSALS a a 9 IFA PROBLEM ARISE CHECK FIRS Toisissa 10 ELECTRICALINTERFAC S 10 GUARANTEE CONDITIONS 11 Safety instructions Please read this operating and maintenance guide carefully and also give it to anyone else assigned the task of handling and using this unit This operating and maintenance guide must be kept during the expected service life of the unit and also always be available at the unit After delivery immediately check the unit for transport damage and make sure it works All safety devices must be present and functional before operating the unit The unit may only be operated in its position of use standing on the rollers Please observe the installation instructions The unit is used to store pre chilled goods Therefore any other use is considered to be improper The unit starts to run straight away once it is connected to its supply voltage Note the power rating on the type plate as well as the relevant local electrical safety regulations before connecting the unit to the power supply Do not heat the unit to more than 70 C 158 F Do n
2. 2 4 Only connect units to power outlets with an earthing contact on a separate circuit You should never connect more than 2 units to any one electric circuit Low voltage or unit disconnections are not permitted because they may lead to malfunctions If these safety regulations are not observed then any claim from the warrantee and or and compensation for damages are excluded 5 START UP AND OPERATION ATTENTION When the supply voltage is connected the cooling unit starts working immediately Before being started up after installation see chapter 3 the unit must reach a minimum temperature of 16 C 60 8 F otherwise the unit must be brought up to ambient temperature Make sure that the products do not block the ventilation grid 6 MAINTENANCE AND CLEANING ATTENTION Do not clean the unit with high pressure cleaners or steam jets ATTENTION Do not warm up units to more than 70 C 158 F and do not subject them to excess heat radiant heaters etc ATTENTION Only the ventilation grill to the condenser may be opened see Figures 2 and 3 Other covers on the unit may only be opened by a trained specialist ATTENTION The condenser must be given a thorough cleaning with a brush vacuum cleaner at least every three months ATTENTION When cleaning the condenser wear safety gloves danger of injury ATTENTION When cleaning the condenser make sure that the fins are not damaged bent Monthly
3. cleaning Unload product Unplug unit Remove Freshboard see Freshboard Manual Allow the cooling unit to defrost for four hours Clean the outside of the unit with a damp cloth Use a mild detergent Dry the previously cleaned surfaces with a dry cloth Setup new Freshboard see Freshboard Manual Plug in the cooling unit Put the products back Cleaning the condenser Clean the condenser with a brush or vacuum cleaner To do this remove the screws on the ventilation grid in order to reach the condenser see Figures 2 and 3 Replace the ventilation grid after cleaning the condenser AAAS I AS Figure 2 The front grill is mounted to the frame Figure 3 After removing the front grill clean the with two magnets at the top condenser 7 TAKING THE UNIT OUT OF OPERATION FOR EXTENDED PERIODS ATTENTION Before moving the e Coolio first drain the water by opening the Ei drain plug see figure 4 Remove or relocate all products Unplug the cooling unit from the mains Remove the Freshboard see Freshboard Manual Release the braking mechanism see figure 1 Use a recipient to collect the water Open the drain plug by turning the cap counter clockwise see Fig 4 Empty the cooling unit by tilting the unit After emptying close the drain plug by turning the cap clockwise Figure 4a Drain plug is placed bottom of the Figure 4b Drain plug ca
4. outlets must not be covered by the Freshboard or products see Freshboard instructions Avoid droughts and major thermal irradiation at the installation site Therefore do not put units in front of radiators heaters or under air vents e Maintain a distance of at least 20cm to neighboring surfaces e g walls Apply brakes to the roller braking mechanism see Figure 1 Figure 1 Steering rollers with braking mechanism Do not point spotlights at the unit Any heat that is incident on the unit will lead to increased operating costs and may have an adverse effect on the performance of the unit 4 ELECTRICAL CONNECTION The national standards and safety regulations for electrical installations must be complied with ATTENTION The mains voltage and frequency must match the nominal values given on the unit s rating plate ATTENTION Work on the electrical systems may only be performed by a qualified electrician The relevant local safety regulations must be observed 6 ATTENTION If the power cord becomes damaged it must be replaced by Aste or the Aste s service partner The unit is a ready to use compact unit The power cord must be connected at the back of the cooling unit The use of extension cables or alternatively multiple power outlets should be avoided if at all possible If it is absolutely necessary then make sure that the cables being used don t fall below the minimum cross section of
5. User Manual 0060 oon oniro onp glun eeceececeo EBEBEBEEBES EBEBBEB5EEEEEE 1 1 1 1 1 1 1 1 1 eoocceeocoooeso EEBEBBBEEBEEE BE EEBDBEBEBBEBEBEBBE e Coolio DECLARATION OF CONFORMITY Leverage from Aste ae EU Declaration of Conformity Manufacturer of the appliance Aste Finland Oy Manufacturer s address Koskivuorenkatu 5 30420 Forssa FINLAND Description of the appliance Commercial Refrigerator Commercial name eCoolio Type marking eCoolio Key to type marking eCoolio Product family Key to serial number A20 020 1234567 A20 Commercial Refrigerator 020 Model 020 EU 010 US 12345678 Specific Serial Number I the undersigned hereby declare that the appliances specified above are in conformity with the Machinery Directive 2006 42 The appliances have been shown through of the tests to applying with the standard EN 60 335 2 89 Date place 12122014 Forssa Signature Jussi Salonen Ze A Position CEO ea Koskivuorenkalu 5 30420 Forssa FINLAND TEL 358 0 29 70 200 150 FAX 358 0 3 424 0699 www astecoolers com sales astecoolers com European Union European Res ronal Deveiogeneni ZT SEPNOARWN SR TABLE OF CONTENTS USAGE tax ewes nad A 5 UNPACKING AND
6. cumstances should you block the ventilation gridd otherwise the air circulation cannot be maintained ATTENTION Any form of unit usage that differs from that which is described is considered to be improper 2 UNPACKING AND HANDLING ATTENTION To prevent the e Coolio from being damaged it may only be transported and stored when in its usage position Non observance of this requirement will result in a loss of warranty If the unit is tilted during transport then wait at least 2 hours before starting it up in order to prevent any damage A visual check must be undertaken before and during unpacking of the unit to check for possible transport damage Please look for dents scratches etc Report any damage to Coolio Intl and your distributor immediately Furthermore Aste s terms and conditions are applicable 3 INSTALLATION ATTENTION See Coolio Freshboard Instructions for assembly of the Freshboard ATTENTION Do not expose the unit to direct sunlight ATTENTION Only authorized service personnel may change the preset temperature with the temperature controller Only use the e Coolio indoors e Install the unit in a well ventilated location sure it is stable and horizontal The Freshboard must it exactly on the e Coolio otherwise the unit may not be used It must always stand vertically on the unit Air circulation around the unit must not be impeded The unit s air inlets and
7. display as described in the placement conditions and recommendations for handling amp placement The guarantee covers all mechanical cooling parts servicing hours for these parts Repairs during the guarantee period must be done by Coolio International appointed technicians unless otherwise agreed beforehand in writing Repairs or maintenance during the guarantee period must reported to Coolio International before starting Guarantee doesn t cover or exclude by abusive use negligence of own maintenance use of other cardboard display then Freshboards unnecessary interventions e g technician states that fridge is working placement conditions haven t been adhered to etc outdoor use transport costs regarding maintenance or repairs After the period of guarantee Coolio Intl will have all necessary spare parts in stock in order to provide a satisfactory service to the technician appointed by the purchaser of the fridges The purchaser of the coolers has to inform Coolio Intl about the appointed technician so that maintenance guidelines can be sent Coolio Intl will give this technician the necessary support 11 COOLIO COOLIO INTERNATIONAL BELGIUM info coolio international com Tel 32 3 260 4651 www coolio international com MANUFACTURED BY Aste FINLAND ASTE FINLAND OY info astecoolers com Tel 358 2970 200 160 www astecoolers com
8. ot expose the unit to direct sunlight Do not clean the unit with highpressure cleaners or steam jets Work on the electrical system and refrigeration system may only be performed by specialists If this is not observed all guarantee and liability claims become null and void IMPORTANT Lack of maintenance will cause e Coolios to break down Keep the condenser grill clean and free of obstruction It must stay open to circulate air for cooling Care and maintenance of your e Coolio Unit Clean the condenser front grill at least once a month with a brush vacuum cleaner Condenser must be cleaned at least 4 times a year with a vacuum cleaner Clean the in and outside of the display with water and a non aggressive detergent Remember to leave 8 between the back of the dis play and the surface behind it Do not stack anything in front of the condenser grill Airflow is important in order to perform properly ob ON Grill Compressor Grille condensateur 1 USAGE Operate the unit a temperature range of 16 C 60 8 F to a maximum of Ei 25 C 77 F and in maximum relative air humidity of 60 in accordance with climate class 3 The e Coolio is designed for the storage of refrigerated packaged goods that are already at the desired temperature The unit may only be used together with the Freshboard See Coolio Freshboard Instructions for assembly of the Freshboard Under no cir
9. p has a holder Do not e Coolio try to remove the cap from e Coolio 8 DISPOSAL WARNING Thermal insulation material is EPP Do not put the unit in with regular waste Please check your obligations in accordance with the national WEEE provisions and the local WEEE disposal partner Ensure that the piping is not damaged in the process 9 IF APROBLEM ARISE CHECK FIRST the power plug plugged in properly the socket live the display active Are the air intake openings blocked by products If the fault is not caused by any of these please call your local service partner 10 ELECTRICAL INTERFACES e Coolio includes two different type of electrical interfaces input 230V 50Hz see figure 5 output 12V 2pcs see figure 6 Figure 5 The main power input socket Figure 6 Two 12V outputs for LED lightning 230V is placed on back side of e Coolio are placed on top front of e Coolio 10 11 e Coolio GUARANTEE CONDITIONS General Complaints All possible complaints must be reported at once immediately after detecting the problem Provided with the individual serial number No responsibility will be accepted if these malfunctions are the result of abusive use or negligence COOLIO The guarantee period equals 12 months starting from date of receipt of goods This guarantee covers all problems that have happened within normal transport conditions maintenance and utilization of the