1. 3 4 Noise detection at metallic fittings The testrod point detects leak noise at a fitting water meter valve hydrant etc Depending on the pipeline material for example plastic or metal the frequencies picked up differ significantly Therefore the frequency band for this method is wider than the frequency band for the above surface noise pick up method RD545 Operation Manual 9 Section 4 Searching for leaks You need a systematic approach when locating a leakage in a water pipeline Before attempting to locate the leak it s advised that you first trace the path of the pipeline Then you must locate the general area of the pipe where the leak is located Finally you must pinpoint the leak s location With a systematic approach the complete length of the pipeline must be checked until the leakage is detected 4 1 Locating the leakage area testrod Use the testrod to check any accessible contact points along the pipe The operator must ensure that the noises received are the result of a leakage muffled sound rather than the result of stopper neckings high sound Both sounds are useful when determining the general area of a leakage Note that flow noises can also be generated by regular discharges Figure 5 shows how the leakage area can be narrowed by accessing the measurement data of the contact spot of the particular pipeline The example below shows the highest figures between the measurement points 3 and 4
2. RD545 Acoustic leak detector Operation Manual Issue 2 June 2009 J Radiodetection AN SPX COMPANY 90 RD545 OPMAN ENG 02 ii RD545 Operation Manual Preface Before you begin Thank you for your interest in Radiodetection s RD545 water leak detection and location system Please read this user manual before attempting to use the RD545 system Radiodetection products including this manual are under continuous development The information contained within is accurate at time of publication however the RD545 this manual and all its contents are subject to change Radiodetection Limited reserves the right to modify the product without notice and some product changes may have taken place after this user manual was published Contact your local Radiodetection dealer or visit www radiodetection com for the latest information about the RD545 product family including this manual Important notices General This instrument or family of instruments will not be permanently damaged by reasonable electrostatic discharge and has been tested in accordance with IEC 801 2 However in extreme cases temporary malfunction may occur If this happens switch off wait and switch on again If the instrument still malfunctions disconnect the batteries for a few seconds Safety This equipment should be used by fully qualified and trained personnel only Reduce audio level before using headphones to avoid damaging you
3. 1 Testrod 2 5 2 Ground microphone 2 6 Adjustments 2 6 1 Headphone volume 2 6 2 Adjusting the level display 2 7 Selecting operation mode 2 7 1 Operation modes 2 8 Input settings 2 8 1 Settings overview 2 8 2 Settings NOOOOaag o a agarnka a BHRwOND B AB RD545 Operation Manual v Section 3 Leakage borne noise 3 1 Noise transmission through the pipeline 3 2 Noise transmission through the soil 3 3 Above ground noise pick up method 3 4 Noise pick up at the outside of the pipeline Section 4 Searching for leaks 4 1 Locating the leakage area testrod 4 2 Pinpointing leaks Section 5 Appendix 5 1 Specifications vi RD545 Operation Manual oo o 10 12 13 13 Section 1 Introduction 1 1 General information The RD545 leakage detection system combines decades of experience and state of the art sensor technique with the latest electronic technology The RD545 allows an untrained operator to locate leakages with ease Leakage borne noises are amplified and interfering noises are filtered out A major advantage of the RD545 is that it offers an automatic saving of measurement data to memory In summary the RD545 features Ease of operation Leakage noise amplification Advanced filtering Rapid on screen leak detection Automatic backlit LCD 1 2 System components 1 unit 1 unit 1 unit 1 unit RD545 central unit leveling base headphones operator s manual 1 unit tes
4. Therefore the leakage must be located between these two contact spots When narrowing a leakage the operator has to make sure that no measurement data exceeds the scale range so that the maximum value can be identified If a measurement point shows a full scale reflection re adjust the display with the control knob 3 or the adjusting knob 1 e g up to 50 so that an increase in reflection is visible In the case of a reduced reflection the pipeline section concerned has to be checked again in order to identify the actual increase and decrease of the volume and thus to identify the two maximum values The measurement data memory has proved to be an enormous advantage as the last data is at the user s disposal until the next measurement procedure starts The pipeline section with the highest noise intensity can be determined if the adjustments of the RD545 are not changed The following above surface leakage detection procedure then has to be carried out on the particular pipeline section 10 RD545 Operation Manual Leckort x Pkt 2 xX aa gt gt bd be Pkt x Pkt 3 Leckort leakage spot Figure 5 Locating leaks with the testrod RD545 Operation Manual 11 4 2 Pinpointing leaks If the testrod has located a leak noise you can apply the ground microphone to pinpoint the leak When moving the ground microphone equipment the operator must ensure that the sounding points are sufficiently close to each other otherwise the operat
5. of 00 99 The signal s noise is also played through the headphones You can adjust the position of the display using the amplification control 5 so that the displayed noise level is in the middle of the screen this allows the user to view all possible peaks and troughs NOTE Changing the position of the amplification control will overwrite displayed data RD545 Operation Manual 5 2 7 Selecting operation mode Pressing the adjustment control will allow the user to access the operation mode selection field The display will show the selected mode as a flashing icon Press the adjustment control key again to change the operation mode 2 7 1 Operation modes GEO Geophone or testrod measurement procedure PWG Search pipelines with the ground pick up pipeline to be irradiated acoustically by Pulse Wave Generator GTX Search empty pipelines pipeline to be irradiated through loudspeakers 2 8 Input settings Input parameters switch off time general setting for hearing shock protection hearing shock protection for PWG measurement display serial number 2 8 1 Settings overview Switch off time Period of time between the last geophone operation and the automatic switch off of the RD545 General settings for hearing shock protection Strong short term noises such as water hammer can potentially damage the user s hearing To reduce risk the RD545 geophone features hearing shock protection In the event of wat
6. charging through microcontroller lt 10U 7 2 volt about 20 hrs under normal conditions bayonet type 6 3mm mono jack type between 15 C and 55 C between 25 C and 65 C 210 120 105mm about 1 700 gram Specifications are subject to change without prior notice RD545 Operation Manual 13 America Radiodetection 154 Portland Road Bridgton ME 04009 USA Tel 1 207 647 9495 Toll Free 1 877 247 3797 Fax 1 207 647 9496 Email rd sales us spx com Web www radiodetection com Pearpoint 72055 Corporate Way Thousand Palms CA 92276 USA Tel 1 800 688 8094 Tel 1 760 343 7350 Fax 1 760 343 7351 Email pearpoint sales us spx com Web www radiodetection com Radiodetection Canada 344 Edgeley Boulevard Unit 34 Concord Ontario L4K 4B7 Canada Tel 1 905 660 9995 Toll Free 1 800 665 7953 Fax 1 905 660 9579 Email rd sales ca spx com Web www radiodetection com Europe Radiodetection Ltd UK Western Drive Bristol BS14 OAF UK Tel 44 0 117 976 7776 Fax 44 0 117 976 7775 Email rd sales ukK spx com Web www radiodetection com Radiodetection France 13 Grande Rue 76220 Neuf March France Tel 33 0 2 32 89 93 60 Fax 33 0 2 35 90 95 58 Email rd sales fr spx com Web http fr radiodetection com Radiodetection Benelux Industriestraat 11 7041 GD s Heerenberg Netherlands Tel 31 0 314 66 47 00 Fax 31 0 314 66 41 30 Email rd sales ni spx com Web
7. er hammer or other pipeline noised the RD545 will automatically reduce amplification to help prevent damage to hearing The user can adjust the sensitivity of the hearing shock protection to suit their preferences NOTE The device must be switched off before setting the parameters 6 RD545 Operation Manual Hearing shock protection for PWG measurement Unlike regular geophone measurement procedures the clearest noise is received by a PWG measurement Therefore the shock protection should be switched off NOTE The RD545 has to be switched off before setting the parameters displaying the device parameters Procedure 1 Plug in power supply unit 2 When is displayed press the adjust key and the switch on key simultaneously The display will read OK and display a two digit number representing a menu choice By pressing the power key the selected option will be initiated 01 Switch off time 00 Pressing the adjust key cancels the menu 05 Version number 04 Serial number 03 Set hearing shock protection for PWG 02 General setting for hearing shock protection 2 8 2 Settings Press the adjustment control key to activate the menu for changes A tick v will be displayed and the changes will be implemented The start key selects the specific option 01 Set the switch off time Calculation of the switch off time as follows The set figure is 2 Example 20 sec 20 sec X 2 60 sec Press the adju
8. http nl radiodetection com Radiodetection Germany Groendahischer Weg 118 46446 Emmerich am Rhein Germany Tel 49 0 28 51 92 37 20 Fax 49 0 28 51 92 37 520 Email rd sales de spx com Web http de radiodetection com Asia Pacific Radiodetection Asia Pacific Room 708 CC Wu Building 302 308 Hennessy Road Wan Chai Hong Kong SAR China Tel 852 2110 8160 Fax 852 2110 9681 Email rd sales cn spx com Web www radiodetection com Radiodetection China Hongfu Mansion Room 61622 Zheng Ge Zhuang Bei Qi Jia Town Chang Ping District Beijing 102209 China Tel 86 0 10 8975 5540 Fax 86 0 10 8975 5640 Email rd service cn spx com Web http cn radiodetection com Radiodetection Australia Unit 14 5 7 Prosperity Parade Warriewood NSW 2102 Australia Tel 61 0 2 9979 8555 Fax 61 0 2 9979 7733 Email rd sales au spx com Web www radiodetection com www radiodetection com Radiodetection products are under continuous development and are subject to change we reserve the right to alter or amend any published specification without notice Copyright 2009 Radiodetection Ltd SPX Corporation All rights reserved Radiodetection Ltd is a subsidiary of SPX Corporation Radiodetection AN SPX COMPANY
9. ntral unit or by initiating a measurement via the handle of the connected sensor 2 3 Battery control The LCD displays the current voltage and reminds the user to charge the device when necessary 2 4 Level display and data memory Measurement 1 Measurement 2 Measurement 3 Measurement 4 Measurement 5 When the activation key on the handle of the sensor or the central unit is released the system will save the current minimum value The display shows the last 5 levels and the current level simultaneously 4 RD545 Operation Manual 2 5 Microphone connection The input socket 2 for the ground microphone and the testrod is located on the side of the device 2 5 1 Testrod The testrod is used to listen to directly accessible contact points such as hydrants and valves to pinpoint the location of the pipe fracture 2 5 2 Ground microphone The broadband type ground microphone 70 800 Hz can locate all leak noise It is used above ground and is suitable for use with soil types 2 6 Adjustments 2 6 1 Headphone volume You can adjust the headphone volume to suit your preferences by using the adjusting knob 4 or the receiver earpiece The headphone volume is automatically reduced for hearing shock protection purposes when the leak noise is too loud symbol 7 hammer displayed 2 6 2 Adjusting the level display The signal received by the ground microphone is displayed on the LCD 2 as a 2 digit number in the range
10. or might miss the leak Figure 6 below shows the recommended distances for cast iron pipelines 250 cm steel pipelines 150 cm plastic pipelines 75 cm As shown in the chart above to determine the exact location of the leak you should position the ground microphone directly above the pipeline For example an error margin of 1m can occur when searching for a leak on a plastic pipeline If the path of the pipeline is not known the operator might have to apply a search pattern the coordination width of this pattern depends on the pipeline material see above If the path of the pipeline is unknown and you do not follow a search pattern then you may fail to pinpoint the leak Figure 6 noise propagation depending on the pipeline material 12 RD545 Operation Manual Section 5 Appendix 5 1 Specifications Amplification Input impedance Filter testrod Filter ground microphone Functions Adjust function Display Displayed data Dimensions L W H central unit Weight central unit 2 60 000fold with low noise factor 1 MQ 70 Hz 4 000 Hz 250 Hz 2 000 Hz 250 Hz 1 000 Hz 200 Hz 800 Hz 100 Hz 500 Hz 70 Hz 250 Hz automatic last 6 measurements detecting pipeline fractures locating pipelines receiver display sensitivity automatically set automatically illuminated LCD current value minimum value averaged value remaining battery capacity state of
11. r hearing A WARNING This equipment is NOT approved for use in areas where hazardous gases may be present RD545 Operation Manual iii Radiodetection provides training services for most Radiodetection products Our qualified instructors will train equipment operators or other personnel at your preferred location or at Radiodetection headquarters For more information go to www radiodetection com or contact your local Radiodetection representative RD545 is a trademark of Radiodetection Ltd Copyright statement Copyright 2009 Radiodetection Ltd SPX Corporation All rights reserved Radiodetection is a subsidiary of SPX Corporation SPX and Radiodetection are trademarks of Radiodetection Ltd and SPX Corporation Due to a policy of continued development we reserve the right to alter or amend any published specification without notice This document is protected by copyright and may not be copied reproduced transmitted modified or used in whole or in part without the prior written consent of Radiodetection Ltd iv RD545 Operation Manual Table of contents Preface Before you begin Important notices General Safety Training Trademarks Copyright statement Section 1 Description 1 1 General information 1 2 System components 1 3 Display 1 4 Central unit Section 2 Operation 2 1 Charging the batteries 2 2 Switch on RD545 2 3 Battery control 2 4 Level display and data memory 2 5 Microphone connection 2 5
12. st key again to accept the setting The display now shows a tick v RD545 Operation Manual 7 02 General setting for hearing shock protection The figures represent 1 High sensitivity 2 Medium sensitivity 3 Low sensitivity O Hearing shock protection de activated Press the adjust key again to accept the setting The display now shows a tick v 03 Setting hearing shock protection for PWG measurement The figures represent 1 2 3 Shock protection activated 0 Shock protection de activated 8 RD545 Operation Manual Section 3 Leakage borne noise Every pressurized pipeline system creates leak noise at a fracture point Different sizes and dimensions of pipeline cracks or fractures result in different noise volumes and frequencies There are two ways of using the RD545 to detect leak noise 3 1 Noise transmission through the pipeline Fittings such as hydrants valves and other metallic connections can transmit leak noise Normally fractures on plastic pipelines are accompanied by low frequency leak noise and fractures on metallic pipelines generate high frequency leak noise 3 2 Noise transmission through the soil The soil around the leakage spot is activated due to the energy of the leaking fluid The vibrations can be acoustically detected on the surface 3 3 Above surface noise pick up method Experience has shown that frequencies between 70 800 Hz are indicators of leak noise
13. trod 1 unit charger 1 unit ground microphone including cable RD545 Operation Manual 1 1 3 Display Figure 1 RD545 LCD _ oon oOo oF F O DS Saved minimum levels of previous measurements Minimum level of current measurement numerical Present level of current measurement Minimum level of current measurement graphical Adjustment of amplification sensitivity Display headphones Headphone noise reduction Automatic display modulation Frequency adjustment geophone PWG measurement 10 Mode of operation GEO PWG GTX 11 Battery status 2 RD545 Operation Manual 1 4 Central unit Controls a F oO N Connections Aa oO N Adjustment control 1 LCD Start button Setting display sensitivity Headphone volume control Select frequency Battery charger Ground microphone input Headphones Photo sensor 3 Figure 3 Connection sockets Adjustment control for automatic amplification Figure 4 Adjustment knob RD545 Operation Manual 3 Section 2 Operation 2 1 Charging the batteries Connect the battery charger to the power supply 220 volt and to socket 6 of the RD545 The charging status is displayed while the battery is being charged Charging is completed when the display reads O K Internal software prevents the batteries from being damaged or overcharged 2 2 Switch on RD545 RD545 can be switched on either by pressing Start 2 on the ce