Home
Oximeter - CMS50EL Pulse Oximeter Instructions Major Features
Contents
1. Oximeter CMS50EL Pulse Oximeter Instructions Principle of the CMS5OEL Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Integrated with SpO gt probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO value display Pulse rate value display bar graph display Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Main performance Display Mode LED display SpO Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO an
2. Battery capacity indication Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function With clock function Review function With data record function of multiuser continuous record about 24 hours data for each user and the record data can be uploaded to computer Touch key operation and locking touch key function It can be connected with adult child or infant oximeter probe Wireless communication function CMS60FW Main performance Display Mode 2 8 TFT Color display Screen Resolution 320 240 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Voltage DC 3 6V 4 2V Power Supply Voltage 3 7 rechargeable lithium battery x 1 Battery working hour 8 hours Battery working life Charge and discharge no less than 500 times Safety Type Interior Battery BF Type Accessories Sell in standard a
3. a user manual Physical Identity Dimension 61 L x 36 W x 32 H mm Weight About 60g with the batteries Oximeter PM60E Pulse Oximeter CO2 Apparatus Feature PM60E base on the intellectualized operating system flat provide the analyze function of CO after the patient breath out and provide accurate data and analyze report for you performance Specifications m Display 3 5 TFT m Display mode Parameter mode amp Waveform face m Battery Built in Li Polymer 6 hours for charging 3 7v 1900mah 9 hours for continuous working in the mode 1 or 2 3 hours for continuous working in the mode 3 or 4 4 hours for continuous working in the mode 5 m Trend Graph Table Resolution from 1s 5s 10s 30s 1min and so on Storage of latest 96 hours trend data SpO gt drop analysis m History Storage of latest 10000 case histories in SD card m Wave Storage of 24 hours waveform and only the real time stored patients have waveform m Alarm Adjustable High and Low limits Three level audible and visual alarm latest 50 alarm information and waveform displays 8 seconds which 4 seconds are before a certain time when the alarm is turned on and 4 seconds are after appointed time when the alarm is turned on SPO2 Measurement Range 0 100 m Resolution 1 m Accuracy 2 70 100 0 69 unspecified m Alarm Range 0 100 m Refreshing Rate 1s Pulse Rate Measurement Range 25 250 bpm m Ala
4. The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 100mA Voltage DC 3 6V 4 2V Power Supply Voltage 3 7 rechargeable lithium battery x 1 Battery working hour 10 hours Battery working life Charge and discharge no less than 500 times Safety Type Interior Battery BF Type Accessories Sell in standard mA user manual mA data line mA disk PC software mAn adult oximeter probe ml wo One off adhesive SpO2 probe mA power adapter GTM41076 0605 or CMS0105 Sell in addition mOther oximeter probe Refer to probe application instruction for details and notice renewal Physical Identity Dimension 63 L x 55 W x15 H mm Weight About 45g with the lithium battery Oximeter CMS50QB Pulse Oximeter Instructions Principle of the CMS50QB Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features maIntegrated with SpO2 probe and processing d
5. that of darkroom is less than 1 Power Consumption Smaller than 40mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour The minimum continually work time is 15 hours theoretical number is 28 hours Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope a user manual Physical Identity Dimension 65 L x 35 W x 40 H mm Weight About 75g with the batteries
6. 2 value display Pulse rate value display bar graph display Pulse waveform display The display mode can be changed Screen brightness can be changed A pulse rate sound indication With measured data overruns limits and low voltage alarm function the upper down alarm range can be adjustable Battery capacity indication Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function With SpO2 value and pulse rate value of storage the storage data can be uploaded to computers Real time data can be transmitted to computers Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe ORF Wireless communication function option only applied for Ver6 6R or above Connected with an external oximeter probe option CMSSOEW only applied for Ver6 6R or above of CMSS50E Main performance Display Mode 1 3 65K Color OLED display Screen Resolution 128 96 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger gt Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 Sp
7. L1 Pulse Oximeter Instructions Principle of the CMS50DL1 Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO2 value display Pulse rate value display bar graph display Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Main performance Display Mode LED display SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse ra
8. O2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 100mA Voltage DC 3 6V7 4 2V Power Supply Voltage 3 7 rechargeable lithium battery x 1 Battery working hour 20 hours LJ Battery working life Charge and discharge no less than 500 times Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope a user manual a data line a disk PC software a power adapter GTM41076 0605 CMS0105 Sell in addition Oximeter Probe Refer to probe application instruction for details and notice renewal RF Wireless Module only applied for Ver6 6R or above of CMS50E Physical Identity Dimension 57 L x 32 W x 30 H mm Weight About 50g with the lithium battery Oximeter CMS50D Pulse Oximeter rai LE j il as 2 at aE AAGEATIP OKIMETER Instructions Principle of the CMS50D Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare p
9. and notice renewal Physical Identity Dimension 58 L x 36 W x 26 H mm Weight About 45g with a lithium battery Oximeter CMS50D Pulse Oximeter Instructions Principle of the CMS50D Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption Operation menu for the function setting SpO2 value display Pulse rate value display bar graph display Pulse waveform display The display mode can be changed A pulse rate sound indication With measured data overruns limits and low voltage alarm function the upper down alarm range can be adjustable Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function With SpO2 value and pulse rate value of storage the storage data can be uploaded to compute
10. can be shown correctly when pulse filling ratio is 0 4 SpO gt error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to Surrounding Light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Voltage DC 3 6V 4 2V Power Supply Voltage 3 6 rechargeable lithium battery x 1 Battery Working Hour 2 hours Battery working life Charge and discharge no less than 300 times Safety Type Interior Battery BF Type Accessories Sell in standard mA user manual mOne rechargeable button lithium battery mCharge accessories One power adapter one charger one data line Physical Identity Dimension 32 L x 28 W x 40 H mm Weight About 14g with a button lithium battery Oximeter CMS50I CMSS50IW Pulse Oximeter Instructions Principle of the CMS5OI Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features aSmall in volume light in weight and convenient in carr
11. d pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO gt error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 30mA Voltage DC 3 6V 4 2V Power Supply Voltage 3 7 rechargeable lithium battery x 1 Battery working hour Theoretical number is 20hours Battery working life Charge and discharge no less than 300 times Safety Type Interior Battery BF Type Accessories Sell in standard A hanging rope A user manual A data line A power adapter GTM41076 0605 CMS0105 Physical Identity Dimension 57 L x 32 W x 30 H mm Weight About 50g with a lithium battery Oximeter CMS50ED Pulse Oximeter Instructions Principle of the CMS50ED Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Integrated with SpO gt probe a
12. ge data can be uploaded to computers Real time data can be transmitted to computers Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Can be connected with an external oximeter probe optional Main performance Display Mode 1 3 65K True color OLED display Screen Resolution 128 96 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 100mA Voltage DC 3 6V 4 2V Power Supply Voltage 3 7 rechargeable lithium battery x 1 Battery working hour 20 hours Battery working life Charge and discharge no less than 500 times Safety Type Interior Battery BF Type Accessories Sell in standard A hanging rope A user manual A data line A disk PC software Sell in addition A Oximeter Probe Refer to probe application instruction for details
13. geable lithium battery x 1 Battery working hour 6 hours Battery working life Charge and discharge no less than 300 times Safety Type Interior Battery BF Type Accessories Sell in standard ma hanging rope ma user Manual mOne rechargeable button lithium battery mCharge accessories One power adapter one charger one data line Physical Identity Dimension 46 L x 40 W x 29 H mm Weight About 35g with a rechargeable button battery Oximeter CMS50QA Pulse Oximeter Instructions Principle of the CMS50QA Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features aIntegrated with SpO2 probe and processing display module aSmall in volume light in weight and convenient in carrying mOperation of the product is simple low power consumption eSpO2 value display mPulse rate value display bar graph display mA pulse rate sound indication aWith measured data overruns limits and low voltage alarm function mLow voltage indication low voltage ind
14. hysical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO2 value display Pulse rate value display bar graph display Pulse waveform display The display mode can be changed Screen brightness can be changed Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Display format can be saved after power off Main performance Display Mode 0 96 Dual color OLED display blue and yellow Screen Resolution 128 64 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the co
15. icator appears before working abnormally which is due to low voltage and with alarm function sAutomatically power off function when the device is under the state of measuring interface It will automatically power off within 5 seconds if the finger falls out of probe aSmall appearance more fit for children Main performance Display Mode Segment LCD display SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 50mA Voltage DC 3 6V 4 2V Power Supply Voltage 3 6 rechargeable lithium battery x 1 Battery working hour 10 hours Battery working life Charge and discharge no less than 300 times Safety Type Interior Battery BF Type Accessories Sell in standard ma hanging rope ma user manual mOne rechargeable button lithium battery mCharge accessories One power adapter one charger one data line Physical Identity Dimension 46 L x 40 W x 29 H mm Weight About 35g with a button
16. is 4 pulse rate error is 2 bpm or 2 select larger v Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 v Power Consumption less than 25mA v Voltage DC 2 6V 3 6V v Power Supply 1 5V AAA size alkaline batteries x 2 v Battery working hour Theoretical number is 20hours v Safety Type Interior Battery BF Type Accessories Sell in standard v a hanging rope v a user manual Physical Identity Dimension 57 L x 31 W x 32 H mm Weight About 50g with the batteries Oximeter CMS50E Pulse Oximeter Instructions Principle of the CMS50E Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption Operation menu for the function setting SpO
17. isplay module aSmall in volume light in weight and convenient in carrying sOperation of the product is simple low power consumption eSpO2 value display mPulse rate value display bar graph display Pulse waveform display ml he display mode can be changed aWith measured data overruns limits and low voltage alarm function mLow voltage indication low voltage indicator appears before working abnormally which is due to low voltage sAutomatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe mDisplay format can be saved after power off aSmall appearance more fit for children Main performance Display Mode 0 96 Dual color OLED display Screen Resolution 128 64 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 80mA Voltage DC 3 6V 4 2V Power Supply Voltage 3 6 rechar
18. lithium battery Oximeter CMS50H Pulse Oximeter Instructions Principle of the CMS50H Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption Operation menu for the function setting SpO2 value display Pulse rate value display bar graph display Pulse waveform display Perfusion Index value display With direction sensor the display direction can be changed by automatic or manual mode Screen brightness can be changed A pulse rate sound indication With measured data overruns limits and low voltage alarm function the upper down alarm range can be adjustable Battery capacity indication Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function With SpO2 value and pulse rate value of storage the stora
19. n SpO2 value display Pulse rate value display bar graph display Pulse waveform display The display mode can be changed Screen brightness can be changed Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Display format can be saved after power off Main performance Display Mode 0 96 Dual color OLED display blue and yellow Screen Resolution 128 64 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 30mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour Theoretical number is 32 hours Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope
20. n Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO2 value display Pulse rate value display bar graph display Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage Automatically power off function when the device is under the state of measuring interface It will automatically power off within 5 seconds if the finger falls out of probe Various color of cover can be selected Main performance v Display Mode LED display v SpO2 Measuring Range 0 100 the resolution is 1 v Accuracy 70 100 2 Below 70 unspecified v PR Measuring Range 30bpm 250bpm the resolution is 1bpm v Accuracy 2bpm or 2 select larger v Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error
21. nd processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO value display Pulse rate value display bar graph display Pulse waveform display The display mode can be changed Screen brightness can be changed Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Display format can be saved after power off Main performance Display Mode 0 96 Dual color OLED display blue and yellow Screen Resolution 128 64 SpO Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO gt error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 30mA Voltage DC 3 6V 4 2V Power Supply Voltage 3 7 rechargeable lithium battery x 1 Ba
22. ndication low voltage indicator appears before working abnormally which is due to low voltage with alarm function Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Display format can be saved after power off Main performance Display Mode 0 96 Dual color OLED display Screen Resolution 128 64 SpO Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger PI Measuring Range 0 20 Resolution 0 1 Measurement Performance in Weak Filling Condition SpO and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO gt error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 80mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour Theoretical number is 24 hours Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope a user manual Physical Identity Dimension 57 L x 31 W x 32 H mm Weight About 50g with the batteries Oximeter CMS50D
23. ndition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 30mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour Theoretical number is 32 hours Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope a user manual Physical Identity Dimension 57 L x 31 W x 32 H mm Weight About 50g with the batteries Oximeter CMS50L Pulse Oximeter a k iin Instructions Principle of the CMS50L Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features mIntegrated with SpO2 probe and processing display module aSmall in volume light in weight and convenient in carrying mOperation of the product is simple low power consumption aSpO2 value display mPulse rate value display bar graph display mLow voltage indication low voltage indicator appears before working abnormally which is due to low voltage sAutomatically p
24. o computers Real time data can be transmitted to computers Connected with an external oximeter probe aWireless communication function CMS60DW Main performance Display Mode 1 8 Color OLED display Screen Resolution 160 128 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 100mA Voltage DC 2 6V 3 6V Power Supply Dry battery 2AA Battery working hour Theoretical number is 44 hours Safety Type Interior Battery BF Type Accessories Sell in standard mA user manual mA data line mA disk PC software mAn oximeter probe Sell in addition mOther oximeter probe Refer to probe application instruction for details and notice renewal Physical Identity Dimension 110 L x 60 W x 23 H mm Weight About 180g with Alkaline battery 2AA Oximeter CMS50DL Pulse Oximeter Instructions Principle of the CMS50DL Pulse Oximeter is as follows Photoelectric Oxyhemoglobi
25. ower off function when the device is under the state of measuring interface It will automatically power off within 5 seconds if the finger falls out of probe Main performance Display Mode LED display SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 25mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour The minimum continually work time is 24 hours theoretical number is 56 hours Safety Type Interior Battery BF Type Accessories Sell in standard ma hanging rope ma user manual Physical Identity Dimension 66 L x 36 W x 33 H mm Weight About 50g with the batteries Oximeter CMS50A Pulse Oximeter Instructions Principle of the CMS50A Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be u
26. rm Range 25 250 bmp m Resolution 1bpm m Accuracy 3 bpm m Refreshing Rate 1s ETCO2 Measurement Range 0 150 mmHg m Resolution 0 1mmHg m Accuracy 2mmHg m Alarm Range 0 150 mmHg AWRR Measurement Range 0 150 bpm m Resolution 1bpm m Accuracy 1bpm m Alarm Range O 150bpm Components m Main Unit SpO gt Sensor m 1 G HighSpeed SD Card a MicroStream EndTidal CO Module Oximeter CMS50R Pulse Oximeter Major Features Integrated with SpO gt probe and processing display module aSmall in volume light in weight and convenient in carrying sOperation of the product is simple low power consumption aSpO gt value display Pulse rate value display aWith measured data overruns limits and low voltage alarm function Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function sAutomatically power off function when the device is under the state of measuring interface It will automatically power off within 5 seconds if the finger falls out of probe mFashion appearance ring style Main performance Display Mode segment LCD display SpO Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO and pulse rate
27. rs Real time data can be transmitted to computers RF Wireless communication function option Connected with an external oximeter probe option Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Main performance Display Mode 0 96 Dual color OLED display Screen Resolution 128 64 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 80mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour The minimum continually work time is 24hours theoretical number is 32 hours Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope a user manual a data line a disk PC software Sell in addition Wireless Module Oximeter Probe Refer to probe application instruc
28. sed in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO2 value display Pulse rate value display bar graph display Pulse waveform display Battery capacity indication Backlight Automatically power off function when the device is under the state of measuring interface it will automatically power off within 5 seconds if the finger falls out of probe Main performance Display Mode 1 3 LCD display Screen Resolution 128 64 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and
29. te can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 25mA Voltage DC 2 6V 3 6V Power Supply 1 5V AAA size alkaline batteries x 2 Battery working hour Theoretical number is 20hours Safety Type Interior Battery BF Type Accessories Sell in standard a hanging rope a user manual Physical Identity Dimension 61 L x 36 W x 32 H mm Weight About 50g with the batteries Oximeter CMS50D1 Pulse Oximeter Instructions Principle of the CMS50D1 Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having Sport and etc Major Features Integrated with SpO2 probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumptio
30. tion for details and notice renewal Physical Identity Dimension 58 5 L x 31 W x 32 H mm Weight About 52g with the batteries a oe Fingertipoximetar Oximeter CMS60D CMS60DW Pulse Oximeter Instructions Principle of the CMS60D Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features aSmall in volume light in weight and convenient in carrying sOperation of the product is simple low power consumption mOperation menu for the function setting eSpO2 value display mPulse rate value display bar graph display Pulse waveform display Screen brightness can be changed mPulse rate sound indication aWith review function aWith clock function aWith measured data overruns limits and low voltage alarm function Battery capacity indication mLow voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function aWith SpO2 value and pulse rate value of storage the storage data can be uploaded t
31. ttery working hour Theoretical number is 20 hours Battery working life Charge and discharge no less than 300 times Safety Type Interior Battery BF Type Accessories Sell in standard A hanging rope A user manual A data line a power adapter GTM41076 0605 CMS0105 Physical Identity Dimension 57 L x 32 W x 30 H mm Weight About 50g with a lithium battery Oximeter CMS60F CMS60FW Pulse Oximeter Instructions Principle of the CMS60F Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption Operation menu for the function setting SpO2 value display Pulse rate value display bar graph display Pulse waveform display PI Display Screen brightness can be changed A pulse rate sound indication With measured data overruns limits and low voltage alarm function the upper down alarm range can be adjustable
32. user manual A power adapter GTM41076 0605 CMS0105 a data line a disk PC software An oximeter probe Sell in addition Other Oximeter Probe Refer to probe application instruction for details and notice renewal Physical Identity Dimension 94 25 L x 55 32 W x 9 6 H mm Weight About 80g with a lithium battery GWERTYUIOR AR OFGHIE LEGYEN Oximeter CMS50G1 CMS50G2 Pulse Oximeter Instructions Principle of the CMS50G1 G2 Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Integrated with SpO gt probe and processing display module Small in volume light in weight and convenient in carrying Operation of the product is simple low power consumption SpO value display Pulse rate value display bar graph display Pulse waveform display PI Display The display mode can be changed Screen brightness can be changed A pulse rate sound indication With measured data overruns limits and low voltage alarm function Low voltage i
33. ying sOperation of the product is simple low power consumption mOperation menu for the function setting eSpO2 value display mPulse rate value display bar graph display Pulse waveform display aWith PI display ml he display mode can be changed Screen brightness can be changed mA pulse rate sound indication aMulti time segment storage aWith measured data overruns limits and low voltage alarm function the upper down alarm range can be adjustable aBattery capacity indication sLow voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function aWith SpO2 value and pulse rate value of storage the storage data can be uploaded to computers Real time data can be transmitted to computers Only CMSS5SOIW Connected with an external oximeter probe Power off long press power button to turn off the device aWireless communication function Only CMSSOIW Main performance Display Mode 1 5 Color OLED display Screen Resolution 128 128 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light
Download Pdf Manuals