Home

M2 –Series User Manual Supplement

image

Contents

1. Intrinsically Safe Control Document for a list of batteries approved for hazardous atmospheres A copy of this drawing accompanies each unit shipped Remove and or replace batteries in non hazardous areas only Battery Operation gt 100 hours continuous use year shelf life auto power off programmable at Disabled 10 20 30 60 or 90 minutes Enclosure 6 9 x 3 8 x 2 3 Polycarbonate Permanently Static Dissipative ESD Protection Enclosure with Boot 7 2 x 4 2 x 2 5 Page 28 Disregard graphics for DI DI w FP and the Notes FP information These are not yet available equipment ea INET 205 Westwood Ave Long Branch NJ 07740 1 877 742 TEST 8378 Fax 732 222 7088 salesteam Tequipment NET May 29 2007
2. Dwg No 9R000062 IR M2 Series User Manual Supplement Reference M2 Manual Dwg No 9RO00045 A M200 Smart Manometer amp M201 Roots Meter Tester The purpose of this Supplement is to provide corrections clarifications or additions to the user information contained in the M2 Series User Manual controlled drawing number 9RO00045 A These corrections clarifications or additions relate to the user interface or available sensor ranges or styles only Changes as of June 06 2007 1 Page 4 Backlight Key delete Red backlight from green red and off description The red position has been eliminated Page 8 Flow Unit Select add information on calculating the Flow constant equation and example Calculate the Flow constant from the following equation F Q DP where F Flow constant Q Flow rate from flow element calculation sheet DP Differential pressure corresponding to Q Example If the DP is 25 units when the flow rate is 10 000 units the Flow constant is 2 000 Page 11 Add clarification note to bottom of Auto Shut Off page to clarify operation when Data Logging or Leak Test features are used The Auto Shut Off timer is suspended during Data Logging and Leak Test sessions to prevent accidental loss of information Auto Shut Off is re instated after completion of Data Logging or Leak Test sessions Page 15 Add clarification note to Data Logging page for Auto Shut O
3. ff timer operation The Auto Shut Off timer is disabled for Data Logging sessions Be sure to end the session to re enable the Auto Shut Off timer Page 16 Add clarification note to Leak Test page for Auto Shut Off timer operation The Auto Shut Off timer is disabled for Leak Test sessions Be sure to end the session to re enable the Auto Shut Off timer Page 23 replace the Specifications Table with the following one added 30 and 300 psig ranges deleted 900 mmHg range converted 2000 mmHg range to 38 psia added 0 1 FS accuracy for 28 inH2O range deleted information for Wet Wet DI and O RING Material 1 May 29 2007 M2 Series User Manual Supplement Reference M2 Manual Dwg No 9R000045 A M200 Smart Manometer amp M201 Roots Meter Tester Type and Range and Display Resolution Differential Non Isolated Types 28 inH20 1 psid XX YYY 200 inH20 7 21 psid XXX YY 2000 inH20 72 1 psid XXXX Y Gauge Isolated Types 15 psig XX YYY 30 psig XX YYY 200 psig XXX YY 300 psig XXX YY 2000 psig XXXX Y Absolute Isolated Types 38 psia 2000 mmHg XX XXY Wet Wet Types hand S pst SSE Accuracy 0 025 of Full Scale or 0 05 of Full Scale 0 1 of Full Scale for 28 inH2O Differential range Includes the combined effects of temperature linearity repeatability hysteresis and resolution Warm up time 5 minutes Unit should be zeroed at working amb
4. ient temperature before use Temperature Storage 40 C to 60 C 40 F to 140 F Operating 5 C to 50 C 23 F to 122 F Media Compatibility PORTS DN Differential pressure non isolated sensors for use with clean dry non corrosive gases only BF GI AI Bifferentrat Gauge or Absolute pressure sensors for use with gases and liquids compatible with 316L SS and O ringnateria D bverrerdittercitiisenscmranty Pressure Limits 2 x range on DN units when pressurized on high side only 150 PSI 10 5 Kg cm static when applied to both sides of sensor simultaneously Connection 1 8 female NPT 316L SS P1 is the high pressure connection and P2 is the low pressure connection Differential port shown below User must use a wrench on the pressure manifold when installing user s 1 8 NPT fitting Do not tighten the fitting without using a wrench on the pressure manifold Failure to use a wrench on the manifold will damage the plastic enclosure and void warranty No torque should be applied to the manifold with respect to plastic enclosure May 29 2007 M2 Series User Manual Supplement Reference M2 Manual Dwg No 9R000045 A M200 Smart Manometer amp M201 Roots Meter Tester Battery Type 4 each AA alkaline batteries IMPORTANT ATEX certified models require the use of approved batteries only to maintain the ATEX certification Refer to Dwg No 9R000056 M2

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger le guide du soupier et la fiche d    Course of programmable logic control (PLC) in - CEUR  Upright Service Manual - Pro  Mantis® Deluxe XP Tiller Operation  Manual de instrucciones    User`s Manual - Fresh Water Systems  取扱説明書 - 日立の家電品  Manual de instrucciones  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.