Home
Datasheet - DATAQ Instruments
Contents
1. Remaining amount indicator Optional Humidity Sensor model B 530 Item Description Alowable temperature range 25 to 80 C Allowable Humidity Range O to 100 Relative humidity measurement accuracy 3 RH 5 to 98 RH at 25 C Response time 15 s 90 response when membrane filter installed Sensor output Cable length Other Optional Accessories Item Option Description 10 www dataq com GL800 External Dimensions m m a aj a o ooocagcaececaooooa ou a oogoo0oog w w o m z 2 z2 2 2 ooocoocoo0oo0coo0o0o0o0000 000 00000000000009 oocoocoocooocoocoococoocoo0oo0oo0oo0oo0ooo0oo0oo0oo0co0oo0oo0oo0oo000000 MoM ss e sm as 020202020 oo 0 05 020202020202020 SeceecaeG Dimensional precision 5 mm Unit mm 330 668 1444 11 www dataq com GL800 Specifications Overall Specifications Number of analog inputs External input output PC interface Internal memory devices Data backup functions Operating Environment Withstand voltage Power supply Power Consumption External Dimensions Weight Vibration tested conditions 1 unit 20 channels Extension unit Maximum 200 channels Trigger input Logic input 4 channels or Pulse input 4 channels Alarm output Ethernet 10Base T 100Base TX USB high speed supported provided as standard features Internal memory approx 12 MB USB memory slot FullSpeed suppo
2. DATA Built in 5 7 TFT LCD Color Display Stand alone or PC connected operation 20 Analog Channels Standard Expandable to 200 Input to output and channel to channel Isolation USB and Ethernet PC Interfaces With its color monitor and internal memory the GL800 is a compact lightweight multi channel data logger that provides 20 standard analog measurement channels expandable to 200 The GL800 is equipped with a large internal flash memory to allow the direct capture of acquired data and its built in USB port may be used to connect any standard USB flash drive for incremental capacity Alternatively the USB or the integral Ethernet port may be connected to a PC to allow data upload in real time or from memory as well as local or remote configuration and real time data acquisition The Ethernet feature includes WEB and FTP server functions which allows monitoring from a remote location as well as data transfer Wide Voltage Measurement Range Each GL800 analog channel can measure from 20 mV to 50 VES across eleven programmable measurement ranges Full Electrical Isolation Per Channel Each analog GL800 channel is electrically isolated from all others and from instrument ground to allow accurate and safe measurements in industrial applications where ground potential differences are common GL800 midi Logger Voltage Current and Temperature Measurement Functions Use the GL800 to measure
3. u a amp 3 g 81 CH1 BEER BRE BRR ERR ERR RRR RRR eRe eee eee eee ee eee ee CH20 Eeeekeeeel Nf aed aat Dag Dll Lt AS n lesleslesleslesieplesles eee eee ees Ile Lb Signal Types and Typical Connections Direct voltage input Thermocouple input Direct voltage Compensation copper wire Direct current input Direct current Shunt resistance Lead wire resistance should be 10 Q or below f Ex for current in the 4 to 20 mA range per wire and equivalent among the three wires apply a resistance of 250 0 1 and perform measurement in the 1 to 5 V range E I A A EE EAA E acsesaeee nee High voltage terminal terminal for high voltage signals E EAT EE ALETA Low voltage terminal terminal for low voltage input signals D a A E Dedicated terminal when connection resistance temperature detector 330 668 1444 4 www dataq com Program the GL800 for Real World Trigger Conditions The GL800 can adapt to just about any trigger condition you might encounter Data recording can be stopped or started as a function of analog signal level a definable alarm condition an external event or specific date and time Beyond initiat ing a data capture cycle the GL800 can also be programmed to set a digital output to flag an external alarm condition And after a trigger condition is executed you can program the GL800 to automatically rearm itself to wait for
4. Device 94y GL800 FOV Y Z 10KO This relay turns ON when alarm is generated 330 668 1444 6 www dataq com Flexible Computer Interfaces and an Optional Battery Pack The GL800 provides the added benefit of PC connectivity to either a USB or Ethernet port Both interfaces are standard and the USB port doubles as a method to expand the GL 800 s internal 12 MB memory to a maximum 2 GB capacity us ing standard USB flash memory When either interface is connected to a PC you can upload measurement protocols to the GL800 monitor acquired data in real time or download previously acquired data The GL800 s Ethernet interface offers the advantage of allowing the GL800 to function as a Web server allowing the GL800 to be manipulated from any web browser such as Firefox or Internet Explorer Finally an optional battery pack may be added to the GL800 to allow power independent data recording whenever and wherever it s required USB Flash Drive Memory Expansion USB to PC Interface Connection USB Memory Ethernet Interface Connection LAN cable Ethernet Deployment Examples Directly to a PC using a cross over cable Over a local area network LAN using hubs or switches 100 meter maximum length unlimited length LAN cable crossing LAN cable straight LAN cable straight www dataq com y 330 668 1444 GL800 Analog Channel Expansion and Extension Options Adding more flexibility to where
5. PULSE LOGIC PULSE input EXT TRIG Trigger input ALARM Alarm output 0 08 6 0 o im Q 6 0 e a 0 0 soe ooe eee 0 Model imprint Battery cover Contains battery pack B 517 sold separately 330 668 1444 2 www dataq com GL800 Analog Input Circuit and Measurement Ranges Each GL800 analog input channel features electrical isolation using a photo MOS relay switching method to maintain safe and accurate measurements in demanding industrial environments Channel Switching Relay Voltage Measurement Ranges per Channel Range Maximum SPAN Minimum SPAN Minimum Resolution Process Current Measurement with external 250 ohm resistor Range Maximum SPAN Minimum SPAN Minimum Resolution 5 500 to 5 500V 0 050V 0 001V Temperature Measurement Ranges per Channel Maximum SPAN Minimum SPAN Measurement ees Minimum Resolution 200 to 1370 200 to 1370 C 200 to 1100 C eee 200to 400 C oR Oto 1600 C 200 to 900 C Lee ee ere 600 to 1920 C 270 to 2000 C Oto 1760 C Oto 1300 C W Ww Oto 2315 C 2 ere 200to 500 C 200to 500 C Optional Humidity Measurement Range Range Maximum SPAN Minimum SPAN Minimum Resolution 0 to 100 0 to 110 Typical GL800 Analog Signal Connections Terminal Configuration 0087 Y20907 Piw OS LHdVYD IWH WO YMO oo0ooqg ooaoaoooooooqaqo0odao ooo0oocoo0oo0oo0coo0oo0o000000000
6. key toggled 100 ms 10 ch maximum 100 200 500 ms 1 2 5 10 20 30 s 1 2 5 10 20 30 min Ih 4 points can be set for each channel Data replay during data capture Capture to internal memory capture to USB memory setup data can be saved copy of data screen saved Types of operation Average value peak value max min value RMS 2 operations can be set simultaneously Method real time and between cursors specified during data replay Note Calculation results are displayed in Digital screen Calculation Display screen Function Search the captured data for the required number of points Search type Channel pulse logic alarm search Function A comment can be input for each channel Inputtable characters Alpha numerics Number of characters 11 8 displayed 10 Analog Channel Specifications Number of inputs Input terminal type Input method Scan speed Measurement Ranges Voltage Temperature Humidity Measurement accuracy Voltage Temperature Thermocouple Resistance Temperature Detector 20 channels maximum 200 channels with exten sion unit M3 screw type terminals Photo MOS relay scanning system All channels isolated balanced input 0 18 10 ch maximum Voltage 20 50 100 200 500 mV 1 2 5 10 20 50 V 1 5 VES Thermocouples K J E T R S B N W WRe5 26 Resistance temperature detector Pt100 JPt100 Pt1000 EC751 Humidity 0 to 100 voltage 0 V
7. resistance Maximum permissible input voltage Withstand voltage Insulation resistance Common mode rejection ratio Noise Filter Internal External switching 14 bits Gain 0 01 of F S C 1 MQ 5 Within 300Q Between terminals Between input terminal input terminal Between input terminal GND 60 Vp p Between input terminal input terminal 1 min at 350 Vp p Between input terminal GND 1 min at 350 Vp p Between Input terminal GND At least 50 MQ at 500 VDC At least 90 dB 50 60 Hz signal source 300 Q or less At least 48 dB with terminals shorted Off 2 5 10 20 40 Filter operation is on a moving average basis The average value of the set sampling count is used Integral TFT LCD Display Display Displayed languages Backlight life Backlight 5 7 inch TFT color LCD QVGA 320 x 240 dots Japanese English Others 50 000 hrs when brightness is down to 50 depends on operation environment Screensaver function 10 30 sec 1 2 5 10 30 60 min www dataq com GL800 Specifications continued Internal Memory Devices Discrete I O Specifications Memory capacity Internal memory approx 12MB Flash memory Input Output types Trigger input 1 ch Logic input 4 ch or Pulse USB memory Max 2 GB input 4 ch Alarm output 4 ch Note Switch between Logic and Pulse Memory contents Setup conditions measured data screen copy as 5 I ifications i i 24 in
8. voltages currents 4 20 mA process currents as well as thermocouple and RTD based temperatures Four Unique Pulse Inputs for Discrete Measurements The GL800 provides discrete input channels that can be used for counting and rotational speed measurement applications Or program the discrete inputs as simple logic level input channels Four Alarm Outputs Program the GL800 to trigger its open collector outputs as a function of analog input signal level judgment pulse judgment or logic pattern Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour Bright TFT LCD Color Display The focal point of the GL800 is its built in 5 7 inch color display that allows real time trending data review and complete instrument configuration Engineering Units Scaling Each GL800 channel allows up to four break points to be programmed for accurate scaling into meaningful units like psi grams newtons gallons per minute etc INSTRUMENTS Flexible Triggering Options The GL800 allows data capture to be started or stopped based upon signal level an external event date time alarm duration or Boolean channel combinations Analog signal triggers can be programmed based upon level and window tests above threshold below threshold inside window or outside window Real Time and Post recorded Calculations The GL800 may be programmed to calc
9. STOP USB DRIVE 14 NAVI 12 CURSOR ALARM CLEAR 11 DISPLAY 10 REVIEW www dataq com 9 330 668 1444 GL800 Included and Optional Accessories Included PC Software Item Description Compatible OS Windows 2000 Windows XP Functions Main unit control real time data capture data conversion Statistic History Displays max min and average values during measurement Included Accessories Item Description Quick Start Guide GL800 UM 8xx CD ROM User s manual application software Optional Battery Pack model B 517 Item Description Capacity 7 2V 2200mAh Battery type Lithium secondary battery Running time lt When LCD is ON gt 1 battery pack MAX brightness approx 2 5 hours MIN brightness approx 3 hours up to 2 battery packs 2 battery packs MAX brightness approx 5 hours MIN brightness approx 6 hours can be mounted lt When LCD is OFF gt 1 battery pack approx 4 5 hours 2 battery packs approx 9 hours Charging method Mount in the main unit Time required for charging 1 battery pack approx 4 hours 2 battery packs approx 8 hours Switchover in the case of Because the battery is used together with the AC adapter the power supply will be switched automatically power failure to the battery in the event of power failure The AC adapter is the primary power source Operating environment 15 to 40 C E cecne When battery is running low file is closed automatically when captured to USB or internal memory
10. and how the GL800 can be deployed the analog input screw terminal unit may be detached from the GL800 and located up to 23 inches away using the optional B 537 Extension Kit If you need channel expansion beyond the 20 channels provided by the base GL800 then use one or more B 538 Expansion Kits plus ONE B 537 Extension Kit to expand your channel count in 20 channel increments to a maximum of two hundred The Terminal Unit may be removed from the GL800 1 Insert tabs at the top oft eerminal unit into the slots Unit 2 CH 21 to 40 Unit 1 CH 1 to 20 Expansion Ordering Chart a 20 Channels 40 Channels 100 Channels 200 Channels 330 668 1444 8 www dataq com GL800 Display Quick look The GL800 s keyboard and display are key components you ll use for any typical data recording session The display is a full color TFT LCD thin film transistor liquid crystal display the same technology used in modern flat panel televi sions The display measures 5 7 inches diagonally and offers 320 x 240 pixels of bright clear high contrast resolution The GL800 s keyboard allows full access to the instrument s menu system as viewed through its display Navigation is straightforward and intuitive using the keyboard s navigation and ENTER keys that form the center of the array Other keys support special operations that are clearly annotated GL800 Display Close up and Modes 3 Device access display 1 Simplifi
11. another trigger event or stop entirely You can even program the GL800 to detect and alarm on a thermocouple burnout condition Here s a summary of the GL800 s trigger and alarm features GL800 Trigger and Alarm Overview Setting Selections Available Start side source setting Stop side source setting i External input none Date Date Time Time Duration Repeated capturing On Off Alarm level settings Mode Level Output Alarm hold On Off Send burnout alarm On Off GL800 Trigger Modes gt Measurement starts alarm generated Above Threshold Below Threshold gt Measurement starts alarm generated Inside Window gt Measurement starts alarm generated CH1 Outside Window www dataq com 5 330 668 1444 GL800 Logic Pulse Alarm and External Trigger Connections The Logic Alarm Cable model B 513 provides access to the GL800 s discrete and pulse inputs external trigger input and alarm outputs The cable is two meters in length and is purchased separately Logic alarm cable B 513 Logic Pulse Specifications Item Description Approx 0 5V 2 5 to 3 V Trigger Input Specifications Item Description Alarm Output Specifications Item Description Number of output channels 4 Output format Open collector output 5V 10KQ pull up resistance Contact capacity 5 V to 24 V 100mA or below Circuit Example of Relay Drive by Alarm Output Alarm Output Circuit External
12. ed message display eid aia GUR bc i 5 Remote display 2 TIME DIV 6 Clock display 2006 12 01 17 Data capture bar 10 34 04 an 16 Upper limit scale MONITOR 8 Waveform control display 9 Digital display T 6 1345 _ WV s So 6 1331 _ V O O P E E Bi i fo 3 0 1316 4 15 Waveform displa 2 2 nf 1A 0 1200 U FEFPLS4 3855C 7A SAMPLE 166ms 10 Quick settings A ZONE izone 14 Lower limit scale ALARM 412 13 File name display 12 Pen display 11 Alarm display MONITOR AMP settings Level settings Digital screen Free Running 1 se DIVER o DATA TRIG USER I F _OTHR HI nenu AMP DATA MA USER IVF OTHR anon Making analog and pulse logic settings Trigger Level Settings Display Logic Pulse Data amp J Display Logic Pulse Data gt CH Input Range Filter EU Misc d Combination Po t 40 ALL CH Mode Lower Level Upper 1 1 40 Ino Fe Lit AAA NISN IR Oo BES OT WwW YTEMP TC T DC lelelelelelels ININININININVININ NIN OPP eli iwiwiwiwlwisifT SN a Kea oad im ied bant bead Gae f zoozoo a lt c lt lt cccccce dadadaaaaaa owOnNOuU ew 3 io ance elp Sets the trigger mode Set the level to suit the waveform ALARM pa COI ok Keyboard Close up 1 CH GROUP 2 SPAN TRACE POSITION 3 TIME DIV 5 QUIT 4 MENU 6 Direction Keys 7 ENTER 8 FAST FORWARD key KEY LOCK 13 FILE 9 START
13. es Ethernet 10Base T 100Base TX USB HighSpeed Inst mode Function Counts the number of pulses for each sampling interval Resets the count value after each Real time data transfer 100 msec 10 ch maximum sampling interval speed Spans 50 500 5000 50 k 500 k 5 M 50 M 500 M CIES Maximum number of Counts Inst modes 50k sampling interval pulse inputs Revolution counts mode 50k s Ordering Guide GL800 i i Extension Terminal Base Set Compact lightweight multi channel data logger l ee B 537 Extension terminal base unit with cable that provides 20 standard analog measurement channels expandable to 200 20 Channel Extension Set 20 channel terminals Extension terminal base unit B 538 Battery Pack connection plate screws 7 2V 2200mAh Battery pack Logic Alarm Cable B 513 DC power cable 2 meter bare tips 2 meter DC power cable bare tips Carrying Case Humidity Sensor ble ith dedicated ei Durable case designed specifically for the GL800 3 meter with dedicated power connector DATA INSTRUMENTS j DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Phone 330 668 1444 Fax 330 666 5434 Data Acquisition Product Links click on text to jump to page Data Acquisition Data Logger Chart Recorder Thermocouple Oscilloscope DATAQ the DATAQ logo and WinDaq are registered trademarks of DATAQ Instruments Inc All rights reserved Copyright 2009 DATAQ Instruments Inc The
14. gle Trigger Function Speci fications nput specifications F nee voltage 0 to V single ended Repeat trigger Off On Input threshold voltage Approx 2 5V Trigger types Start Data capture starts when a trigger is generated Hysteresis Approx 0 5 V 42 5 to 3 V Stop Data capture stops when a trigger is generated Alarm output Output format Open collector output 5 V 10 KQ Trigger conditions Start Off Level External Time Alarm specifications pull up resistance Contact capacity 5 V to 24 V Stop Off Level External Time Duration Alarm 100 mA or below Alarm judgment modes Analog H L Window In Window Out Output conditions Level judgment window judg Logic H t L J ment logic pattern judgment pulse judgment Pulse H 7 L 1 Window In Window Out Pulse input Channel combination OR AND Revolutions mode Function Counts the number of pulses per second PC Interface engines etc enables them to be converted to rpms Spans 50 500 5000 50 k 500 k 5 M 50 M 500 M PRM E S Counts mode Function Displays a count of the number of SUR ALGTUBC LORS ane Side ie tine memory electric meters etc o oe sampling interval from the start of Ethernet functions Web server function Displays GL800s screen Spans 50 500 5000 50 k 500 k 5 M 50 M 500 image on web broser operation of GL800 M CIES FTP server function Transfers and deletes files from internal memory and USB memory Interface typ
15. information on this data sheet is subject to change without notice
16. rted standard Setup conditions EEPROM Clock lithium secondary battery 0 to 45 C 5 to 85 RH 15 to 40 C when using batteries Between each input channel and GND terminal 1 minute at 350Vp p Between each input terminal 1 minute at 350Vp p AC adapter 100 to 240 VAC 50 60 Hz DC input 8 5 to 24 VDC Battery pack option 7 2 VDC 2200 mAh 2 packs mountable AC Power consumption when AC adapter is used Normal Consumption Consumption during Condition battery recharge LCD on 16 VA 28 VA Screensaver on 11 Va 22 VA DC Power consumption DC Voltage Normal Consumption Consumption during Condition battery recharge 24V LCD on 0 3 VA 0 7 VA 24V Screensaver on 0 2 VA 0 6 VA ey LCD on 0 55 VA Can t Recharge 2N Screensaver on 0 3 VA Can t Recharge 8 5V LCD on 0 8 VA Can t Recharge 8 5V Screensaver on 0 45 VA Can t Recharge Note normal status is when LCD brightness is set to MAX 232 x 152 x 50 mm 990g excluding AC adapter and battery Equivalent to automobile parts Type 1 Category A classification Overall Functional Specifications Display Screen Sampling interval EU Scaling function Review function Data save functions Calculation Search functions Annotation input function 330 668 1444 Waveform screen Digital screen Expanded Waveform screen Digital screen Calculation Display screen can be
17. to 1 V scaling conversion with B 530 option 0 1 of Full Scale Measurement Accuracy C Measurement Temperature TE Range C O lt Ts lt 100 100 lt Ts lt 300 R 300 lt Ts lt 1600 S 300 lt Ts lt 1760 400 lt Ts lt 600 600 lt Ts lt 1820 EOZ 3 0 0 05 of rdg 2 0 0 05 of rdg 2 0 35 0 05 of rdg 2 0 200 lt Ts lt 100 100 lt Ts lt 1370 0 05 of rdg 2 0 200 lt Ts lt 100 100 lt Ts lt 800 0 05 of rdg 2 0 0 05 of rdg 1 0 fe he iie he Eg 0 05 of rdg 1 0 200 lt Ts lt 100 100 lt Ts lt 400 0 1 of rdg 1 5 0 1 of rdg 0 5 E t 200 lt Ts lt 100 100 lt Ts lt 100 100 lt Ts lt 1100 E2 17 0 05 of rdg 1 0 0 lt Ts lt 1300 0 1 of rdg 1 0 E E 0 lt Ts lt 2315 0 1 of rdg 1 5 Reference contact compensation accuracy 0 5 C Measurement Tem perature Range C Measurement Accuracy C Applied Type Current Pt100 200 to 850 FS 1050 1mA 1 0 Jpt100 200 to 500 FS 700 1mA 0 8 Pt1000 200 to 500 FS 700 0 2mA 0 8 23 C 3 C when 30 minutes have elapsed after the power was switched on filter On 10 1 s 20 ch sampling GND connected Reference contact compensation accuracy A D converter Temperature coefficient Input resistance Allowable signal source
18. ulate average value peak value minimum value and rms Flexible Power Requirements Power the GL800 from its provided international AC adaptor from an optional built in battery pack or from any 9 to 24 VDC source using an optional cable PC Connectivity via USB or Ethernet Allows data transfer to the PC either in real time or from the GL800 s memory Also allows complete configuration of the GL800 PC Software Bundle Included The GL800 includes a Windows application for direct capture measurement and monitoring of GL800 data In addition to waveform and data value capture and display the application can export data to an Excel file for further analysis and report creation The software includes built in help for quick reference DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Tel 330 668 1444 Email support dataq com www dataq com GL800 Display I O and Control Overview Operation status LED Power switch POWER ON when the power is ON START ON during data capture CHARGE ON while the battery is charging Lh k J _ wv 8 7 n n n oooo0oo0oo0o0o0opooooogooooooooonoo0oo0oo0oo000 ooocoooocooocopooocooogooooocooooo0ooogoooo0o0 PC interface terminals Monitor LAN OCSI Control panel keys AC adapter jack GND terminal USB memory terminal Analog signal input terminals External input output terminal Power jack for the humidity sensor LOGIC
Download Pdf Manuals