1. anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 O 5 Device Description Vane Display LCD Velocity unit select button 4 Calibration and C F button 5 Data hold button v N gt 6 Maximun Average Minimum button T Power Button ON OFF anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 6 Device Operation 6 1 Measuring Air Velocity Follow the arrows to measure velocity As shown in the photo WARNING N Please don t touch the vanes by fingers or foreign body to avoid damage to the vanes anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 6 2 Power Button Press the button more for than 2 seconds to power on the meter Press the button again and the meter will immediately turn off 6 3 Velocity Unit Button Select the unit m s gt Knots kts gt ft min fpm 2 Km hr kph gt mph 6 4 Calibration e Calibration should be set at 10 m s Prepare a known 10m s velocity Press CAL button and POWER button for more than 2 seconds and the LCD will display CAL Press CAL button again for more than 2 seconds and the meter will shut down Your meter is now calibrated 6 5 C F Button Select C F 6 6 MAX MIN AVG Button Press the MAX MIN button MAX will appear and the highest r
2. ANAHEIM SCIENTIFIC User Manual Model M130 Mini Anemometer ANAHEIM SCIENTIFIC Table of Contents 1 ao oa fF WwW N 8 9 1 1 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 7 1 7 2 7 3 INTEODUGETIOM sissies sie RE EE n EN de bed de de ENE ea 3 M130 ie lure es ea SS Ee on ea ee Ge ii ee De E 3 SAFETY SUMMARY esse see ses se de ean vies ea ee ei ee 3 COMPLIANCE STATEMENTS esse sesse see ee ee ee ee ee ee ee see ee ee ee ee ee 4 PRODUCT CONTENTS AND INSPECTION sesse ee ese ese 4 DEVICE DESCRIPTION eisesiessteseseek eise ek Gee dowe n Ee n weke ds 6 DEVICE OPERATION uses seges sessies ese eeu Ek ske ase dus sd N Ge kk kke 7 Measuring Air Velocity iss Se Ser Se ESE die sg EE 7 Power BUIS sesse oe Ge se eie N ee dee 8 Velocity Unit Buenos ee eet ee Ge 8 CalibratlON oes AGE SE EE EE he Ee Oe BE RE GE ES EE iE 8 OF ei ER DEE N DO Ee N EN 8 MAX MIN AVG Button sense sesde Re ee ES DE De Dee De ee ea Ee 8 Data Hold button sie ale ion Ee EG dict ee oe 9 AUO POWER ss ed N AE se Ee Ge We ae ee 9 Beery Replacement es oi N Ee se eed ee 10 TECHNICAL SPECIFICATIONS esse ees ee ee RR Re ee ee ee RR ERG Gee ee 11 General Specifications es EE EE ee ee ee 11 Velocity Specifications ERENS RE EE EA EE 11 Temperature Specifications s ssseeeeeeeeeeeeeeeeeeeeeeees 12 SERVICE REPAIRS CALIBRATION esse ese sees ee se ee ee ee ee ee 12 LIMITED TWO YEAR WARRANT
3. Y sesse ee ee ee ee ee ee ee ee 14 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 1 Introduction Thank you for purchasing a M130 Air Velocity Meter from Anaheim Scientific The M130 measures air speed and temperature It is ideal for spot measurements at air outlets on account of its 30mm vane Durable and reliable the M130 is easy to use 1 1 M130 features Wind speed measurements up to 55 mph 90 kph Measurements in m s km h mph knots or ft min Light air response 0 4m s Max Min Avg and data hold Auto power off with disable function 2 Safety Summary CAUTION AN Adhere to the following conditions for safe and effective usage of this meter Do not operate the meter in an environment filled with combustible gas liquids dust or fibers In order to avoid reading incorrect data please replace the battery immediately when the symbol appears on the LCD anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 4 In order to avoid damage caused by contamination or static electricity do not touch the circuit board before taking adequate precautions Operating Environment Indoors use This instrument has been designed for usage within an environment of pollution degree 2 Please don t touch the vanes by fingers or foreign body to avoid damage to the vanes Operating Envi
4. eading since the meter was turned on will stay showing Press the button again to see AVG the average value This will change as time goes on and anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 9 the average value changes Press the button again for MIN the minimum value Press again to go to MAX again or press for more than 1 second to exit this mode 6 7 Data Hold button Freezes the reading present on the LCD screen at the moment the button is pressed 6 8 Auto Power When the LCD symbol is showing the Auto Power Off feature is engaged To save battery life the meter powers down automatically after approximately 12 minutes of inactivity To turn this feature on or off press and hold the Power Button 6 for more than 2 seconds anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 10 6 9 Battery Replacement WARNING If the symbol appears on the LCD please replace the battery immediately Remove the battery cover Replace the battery Install the battery cover anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 11 1 Technical Specifications 7 1 General Specifications Dual LCD display The maximum value on Display the primary display is 9999 The maximum value on secondary displa
5. ease complete the warranty registration for your new instrument via our website www anaheimscientific com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 15 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 16 ANAHEIM SCIENTIFIC 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 2013 Anaheim Scientific anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412
6. include the return shipping information name address and telephone number anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 13 If the unit is in warranty please provide the following proof of purchase or copy of the original invoice If the unit is out of warranty prepayment is required by Check Money Order or Credit Card Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific ATTN Service Repair 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 14 9 Limited Two Year Warranty Scientific warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To help us better serve you pl
7. ronment 5 C 50 C lt 95 RH lt 2km altitude Storage Environment 10 to 60 C lt 70 RH 3 Compliance Statements Caution This symbol indicates that the equipment and its accessories are subject to special collection and disposal procedures This meter complies with EMC EN61326 1 2006 IEC 61000 4 2 2008 IEC 61000 4 3 2006 2007 4 Product Contents and Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 physical inspection should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any external damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If damage to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection Forward a report of any damage to the agent through which the unit is procured Retain the original packing in case subsequent repackaging for return is required Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included in this package are M130 Meter User Manual Carrying Case 2 x AAA Batteries
8. y is 999 Sampling Ee sample per second Per 2 x AAA Batteries Supply Battery life 50 hours during consecutive use Dimensions 135 x 48 x 23 mm H x W x D Weight 80g excluding the battery Warranty Limited two year warranty 7 2 Velocity Specifications Unit Range Resolution Accuracy mph 09 55 01 2 04 knots kts 08 48 01 2 04 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 12 7 3 Temperature Specifications Unit Range Resolution Accuracy 20 50 O F 4122 8 Service Repairs Calibration The following are instructions regarding policies for servicing repairing or calibrating Anaheim Scientific products Turnaround time is usually less than ten 10 working days unless expedited service is requested and pre arranged Send an email to service anaheimscientific com requesting an RMA number specifying your request for either service repair and or calibration with your product s model number Once you receive a reply from service anaheimscientific com you will be asked to ship prepaid to the address below Package the unit carefully using filler or bubble wrap and if possible ship in the original box Ship each unit separately Anaheim Scientific is not responsible for any shipping damage that may occur Include a packing list with each unit shipped stating what type of service is required and