1. in the first paragraph under the Section Troubleshooting using a testset and loopback the correct spelling of the example testsets should be FIREBERD T BERD or Verilink s TS2000 Red Zone Encryption Management System REMS Release Notes Part Number 883 101598 001 A
2. CC 2020 set the FBR to 40 This is the canned preconfigured FBR option The NCC STATUS light stops flashing 3 As appropriate configure one of the FBRs in the circuit to be Master 64 and the other end Remote 65 4 As appropriate configure the access port to D4 or ESF framing You can also use the ASCII Terminal Interface ATT to set these parameters 5 Select the line code You can also use the ATI to set these parameters If you reset the thumbwheel switches to 40 at any time after performing the above procedure all settings are reset to the defaults You must then reenter the commands that make the configuration unique 4 Red Zone Encryption Management System REMS Release Notes Part Number 883 101598 001 A Procedure for configuring the BRC Part Number 883 101598 001 A Configuring REMS using the thumbwheel switch FBR Thumbwheel Configuration Commands 40 64 65 68 69 70 71 72 73 80 81 82 83 Canned FBR Option 1 Remote REMS is the default FBR is Master FBR is Remote Disable Re sync Default Re sync 2 seconds Re sync 4 seconds Re sync 6 seconds Re sync 8 seconds Re sync 10 seconds D4 ESF AMI B8ZS Using the BRC thumbwheels located on the front panel of the BRC NCC 2020 select the BRC timing mode for each BRC in the circuit Refer to the subsection BRC Timing Options below 1 Access the BRC by entering its location address into its the thumbwheel
3. Release Notes IMPORTANT TIP Access System 2000 Red Zone Encryption Management System REMS Release Notes Read this Release Notes document before you read the REMS user manual This Release Notes provides corrected information for the Red Zone Encryption Management System User Manual Chapter 6 Configuring and starting REMS in the section Configuring REMS using the thumbwheel switches Use the following information instead of section mentioned above Verilink suggests you manually cross out that section in the A 1 rev of the REMS user manual up to but not including the section Interpreting the LED indicators page 6 5 Configuring REMS using the thumbwheel switch Part Number 883 101598 001 A The operator uses the EXE execute and FUNCTION thumbwheel switches on the NCC 2020 modules to configure REMS There are thumbwheel switches in both the FBR and the BRC You must configure the FBR and the BRC separately as if they were two separate AS2000 nodes Figur el NCC Thumbwheel Switches shows the top section of the master NCC 2020 front panel Red Zone Encryption Management System REMS Release Notes 1 Access System 2000 Red Zone Encryption Management System REMS Release Notes CAUTION Do not attempt to use AM2000 or ASClITerminal Interface ATI to configure REMS There are some exceptions which are noted Use only the thumbwheel interface If you accidentally change configuration using
4. itches Part Number 883 101598 001 A Configuring REMS using the thumbwheel switch Each command consists of two digits The switch nearest to the EXE push button sets the first digit of each command and has a TENs arithmetic value The other switch sets the second digit of the command and has a ONEs value Plug in module slot addresses range from 01 to 30 Slot numbers are assigned to dual line and multi lined shelves from left to right continuing from one shelf to another See Figure 2 2 in the Red Zone Encryption Management System User Manual The figure is titled Front Panel View Concept Drawing Dual line and Multiline Shelf Rack Configurations For more information see the AS2000 manuals referred to in the preface of the REMS user manual Every module in an Access System 2000 node has a unique two digit location number or address In a node with two multiline and two dual line shelves the module addresses for thumbwheel switch access are 01 to 13 in the first multiline shelf and 14 to 26 in the second multiline shelf The module addresses in the dual line shelves are 27 and 28 in the first shelf and 29 and 30 in the second shelf If the node has only dual line shelves the module addresses are 01 and 02 in the first shelf and 03 and 04 in the second shelf You must configure the FBR and the BRC separately as if they were two separate AS2000 nodes Accessing modules To access the desired NCC enter its addres
5. s in the thumbwheel switches and press the EXE button twice within one second See Figurel NCC Thumbwheel Switches The STAT LED of the module flashes green indicating that it is accessed and waiting for your next command Once an NCC has been accessed you have 60 seconds to enter another thumbwheel switch command If no command is entered within this time period the accessed module returns to the idle state and its STAT LED goes out Red Zone Encryption Management System REMS Release Notes 3 Access System 2000 Red Zone Encryption Management System REMS Release Notes Procedure for configuring the FBR IMPORTANT Clearing an incorrect address entry If you accidentally access the wrong module enter command 00 and rapidly press the EXE button twice This releases the currently accessed module If you enter command 00 while a QRSS test signal is applied to an NCC or while a loopback is in progress nothing happens The loopbacks must be deactivated first Use the following procedure for configuring the FBR NCC 2020 For list of commands see the subsection FBR Thumbwheel Configuration Commands below 1 Access the FBR by entering its location address into its the thumbwheel switches located on the front panel of the FBR NCC 2020 The STATUS light on the front panel of the NCC begins flashing Green You have 60 seconds to perform the next step 2 Using the FBR thumbwheels located on the front panel of the FBR N
6. switches located on the front panel of the BRC NCC 2020 The STATUS light on the front panel of the NCC begins flashing Green You have 60 seconds to perform the next step Using the FBR thumbwheels located on the front panel of the FBR NCC 2020 set the FBR to 40 This is the canned preconfigured FBR option The NCC STATUS light stops flashing Select the BRC timing mode for each BRC in the circuit Refer to the subsection BRC Timing Options below Red Zone Encryption Management System REMS Release Notes 5 Access System 2000 Red Zone Encryption Management System REMS Release Notes BRC Timing Options Select one of the settings 40 through 43 which are canned programs Then select from 50 through 63 as appropriate 40 Canned program Internal timing generate PRMs Performance Report Messages 41 Canned program Network loop timing generate PRMs 42 Canned program Internal timing no PRMs 43 Canned program Network loop timing no PRMs 50 Internal timing 51 Network loop timing 52 Equipment timing 53 External timing RS442 54 External timing TTL 62 Disable transmit of BRC message 63 Enable transmit of BRC message Correct the error in Troubleshooting chapte On page 8 5 of the rev A 1 Red Zone Encryption Management System User Manual delete step 5 b of the eight step procedure at the top of the page Step 5 b does not apply Correct spelling of T Berd and FireBerd 6 On page 8 4
7. the AM2000 or theATI reconfigure the system using the thumbwhee interface Do not use other thumbwheel commands that you may find in AS2000 manuals Unspecified results may ensue Figure 1 NCC Thumbwheel Switche Press this button twice within 1 second to First digit o q execute the command command TENs Value Second digit of command ONEs Value NOILONNA Push the buttons on this side to decrement the digit values Push the buttons on this side to increment the digit values Using the The system must be powered up before you use the thumbwheel switch thumbwheel interface The thumbwheel switch interface is enabled by default You can switches overview log into Access Manager 2000 AM2000 to verify that the thumbwheel switches are enabled Before entering thumbwheel commands you must address the appropriate FBR or BRC NCC 2020 by entering its slot address number into the thumbwheel switches Slot addresses numbers are two digit numbers that range from 01 to 30 The NCC is typically in slot 01 Configuring the system using the thumbwheel switches is a two step process The operator enters a command by setting the FUNCTION thumbwheel switches to the corresponding command number address The operator then presses the EXE button twice in one second 2 Red Zone Encryption Management System REMS Release Notes Part Number 883 101598 001 A Accessing the NCC 2020 using the thumbwheel sw

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE USUARIO MODULO POS  Industrial Ethernet DIN Rail Switch User's Manual  ASUS X205TA User's Manual  NewsliftLetter  manual de instrucciones - vr-370  Fujitsu ESPRIMO P2760  Emerson Process Management 2088 Satellite Radio User Manual  Multi-rate Sensor Fusion for GPS Navigation Using Kalman Filte  Pro Grout™Xtreme  DeLOCK G4 LED  