1. automatically off Sterilizing is still in process within 20mins after the indicator lamp is off Don t open the door within this period to guarantee the sterilizing effect If you need to cancel any function please press the power button If you open the right door when the right cabinet is working The producer and the heating pipe will stop working Only close the right door and press the right button again can the right cabinet continue to work If you need to turn off the power indicator light then just press the power button How to install Pls read this installation carefully before you install and test it to make sure it s ok when the first time you use this disinfection cabinet Warning A Should install on a wall which can bear weight B Any installations should be undertaken by professional electrician any wrong measures are dangerous C Should not put this disinfection cabinet close to heat source otherwise will occur damage or danger The common fault and how to handle O Door control switch break down Replace the the door control switch zone producer Electronic ballast break down Replace the electronic ballast fail to work Ozone producer break down Replace the Ozone producer Relays break down Replace the relays Heat pipe l Temperature control break down Replace the temperature control fail to work Heat pipe break down Replace the heat pipe
2. onable outlook design and attractive shape The product can control separately by left and right cabinet e With temperature increase to above 120 C the infrared ray produced in the left cabinet can kill 99 9 percent of the colon bacillus staphylococcus and showing negative effect in the HBsAg damaging experiment but does no side effect on human health Ozone in the right cabinet disinfects the colon bacillus and the staphylococcus to some extent and it is fit for keeping clean the tableware of which is not high temperature resistant The left and right cabinet can control exactly it s safe and reliable How to use Clean and dry the tableware put the tableware which need to disinfect drastically into the left cabinet and the low heat resistance ones should be put into the right cabinet Left cabinet Right cabinet Power Left indicator light indicator light indicator light Right Power Plug the power cord and get ready for work Press the power button it means ready to work while the power indicator light turns on Press the left button the left cabinet indicator lamp will be on and the left cabinet start to work Press the right button the right cabinet indicator lamp will be on and the right cabinet start to work If you only need one of the two sides to work you can just press the left button or right button When the temperature is higher than that set by the temperature control the indicator lamp will be
3. ppliance disinfected with ozone UV in the right cabinet and sterilize by far infrared in the left cabinet The product can kill colon bacillus staphylococcus and bacteria causing hepatitis It is an ideal disinfection cabinet for the restaurant kindergarten hotel dining hall and other places Warning Only when the right door is closed can the disinfection cabinet work normally otherwise there will be leak of ozone Do not put any other thing than tableware into the disinfection cabinet In order to achieve the best disinfection result and avoid burning your hands or leak of ozone you are suggested to wait for another 20mins before opening the door after the sterilizing is finished and do not take out the tableware before they cool down Cannot put the plastic and wooden product into the left cabinet High temperature please be careful not to get burnt Special Attention For the tableware of which heat resistance is below 75 C should not be placed in the cabinet For the tableware of which heat resistance is below 180 C such as high temperature resistance plastic materials silicon rubber product or low temperature resistant glass products should not be put into the left cabinet The tableware of which heat resistance is between 180 C to 250 C should be put away about 100mm from the heat pipe Precautions The power supply socket must be reliably ground The user should not change the socket b
4. x y M gt MALLOCA X y DISINFECTION CABINET USER MANUAL MODEL MDC 21C Please read this manual carefully before using the product and keep it properly Location It s convenient for using 1f install the disinfection cabinet above the sink The location of installation must away from the gas hobs and electrical appliance The place where you put or hang the disinfection cabinet should be flat and strong enough otherwise it will deflect or fall Use the M8x60 bolt to fix the 4 part Then fix with the linking plate The picture 1 The install position should keep enough space for opening the door The space landscape orientation should be more than 820mm The picture 2 Front feet Base of the cabinet If the disinfection cabinet put on the table it 1s needed to install the supported feet of the cabinet As the 3 picture 3 use the M5x16 screw to fix the front feet and the back feet of the cabinet Back feet Daily Maintenance It is suggested to clean the product often Remember to disconnect the power supply before cleaning Then use a wet towel with some neutral detergent to wipe off the stain inside or outside of the cabinet and then use a dry towel to wipe off the remaining detergent The common fault and how to handle Thanks for using Malloca disinfection cabinet Malloca disinfection cabinet keeps clean and dries the tableware and a
5. y himself Please E refer to picture 1 Ll The tableware should be dry before putting into the ji cabinet and shouldn t be overlapped to obtain the best sterilizing effect Neutral line Don t touch the glass of the door when it is sterilizing for avoiding being scalded Don t block the Air off hole When the maintenance work is required the power supply should be turned off first Don t put the disinfection cabinet near the tinder and the cloths things are not allowed to put into on or beside the cabinet Please turn off the power supply after sterilizing or finish cleaning As to the special people like children are not suitable to use this disinfection cabinet Earthen line Phase line How to handle the junk product for the junk appliances which excess the safety life or not available with the repair value the user should take the appliance to the recycle enterprise household appliance agent or after sales service center The user is not allow to throw away the junk appliance by themselves Names of Components 1 Body of cabinet 8 Temperature 2 Bowl rack control 2 3 Air hole 9 The right door 4 Temperature 10 Dish rack control 1 11 Heat pipe 1 5 Dish rack 12 Power box 6 Bowl rack 13 Heat pipe 2 7 Ozone producer 14 The left door MDC 21C 220V 50Hz 500W Left cabinet 400W right cabinet 100W Interior volume 60L 30L for the left 30L for the right Features With fashi