1. PRO1 series DIN rail single phase two wire energy meter PRO1D V11 112 PRO1D V11 121 PRO1D V11 122 PRO1D V11 211 PRO1D V11 212 PRO1D V11 221 PRO1D V11 222 PROITE V11 311 L PROITE V11 312 E PRO1TE V11 321 PRO1TE V11 322 Version 1 0 DMMetering Note the picture on the frontpage is a meter from the series of this meter it might not be exactly the same as the meter you have bought 1 Safety instructions cc cecceceecscueeueenceuceueesseusureeseuueuresseuueutenteugeutenseugersenss 3 2 FORE WON G posecorcuawsaescaasaeewescusaawesousemreuesaaauuesssaauarascanrawescqoienawecoieasaaercauus 4 3 Type number table icc cccscisevisenieewissawseneeeensawananiserinanasecinestbevinanvassesseneewas 4 aA MIDC O aa A E EE E ENAA 5 5 Performance Criteria cccccccvecseuseuveccuceuseseeuceueensaueureeneuueuvesseugeusenseueanes 6 o SP CNC AON eE ETES 6 FT BaSlC OTO rasa EE E ETE 7 o PEPON ea ee ee re 7 2 PINEN ONS A A A A A AA AAA EA 8 LO Torge taD a E E aaa 8 LL IAS AON eare EEEE E E 8 I2 OPAO EE EEE E E E E E E EEEE E 9 12 1 Consumption indication s s sesessssssssnsrrrsrrnrnrnrnrnrnrnrnrnnnnnnnnrnrnrnrrrrrnne 9 12 2 R adno Men E aAA EEANN NAA 9 12 3 Mechanical register sssssssssnssnnrnnrnrrrnrrrrrrnrnrrrrnrnnrrrnrnrrrerenrenerenenan 9 12 4 Digital register sesssssunnsnnnnnnunnnsnenrsununnrunnnsnruenusnenruunnenrunnnsneurnnn 10 Lo PULO OUDOT oeren rsa EAEE EES 10 19 MVOUMIDICSI TO OU CO ceress
2. part 3 Particular requirements Static meters for active energy class indexes A B and C Valid until March 30 2020 The results are recorded in the following annex test report 2113897 TDT 6319 10 KEMA Quality B V ir P J J G Nabuurs Managing Director The investigation reported here does not confer any night to use an approbation mark granted by KEMA integral publication of this certificate and adjoining reports s allowed This certificate is issued provided that neither KEMA nor the RvA assumes any liabelty KEMA Nederland B Y Utrechtseweg 310 6812 AR Amhem The Netherfands P O Box 9035 6800 ET Arnhem The Nethertands T 31 0 263562215 F 31 026 4426211 KAL kema com www kemacom handelsregister Amhem 09080262 DMMeteringg 2011 Experience you can trust 5 For the SOP number see section 15 PRO1 V11 xxx DMMetering 2011 6 5 Performance criteria Operating humidity Storage humidity Operating temperature Storage temperature International standard Accuracy class Protection against penetration of dust and water Insulating encased meter of protective class 6 Specifications Meter type Nominal voltage Un Operational voltage Insulation capabilities AC voltage withstand Impulse voltage withstand Basic current Ib Maximum rated current Imax Operational current range Over current withstand Operational frequency range Internal power consumption Test output flash rate
3. to the emitter connection pin 21 Maybe there is a Please contact technical support fault inside the for a meter replacement meter The pulse output Maybe there is a Please contact technical support rate is wrong fault inside the for a meter replacement meter 14 Technical support For questions about one of our products please contact Your local Inepro Metering distributor Email support ineprometering com www ineprometering com 15 SOP Table PRO1D V11 222 mold C PROITE V11 311 mold C PROITE V11 312 mold C 0067 S PROITE V11 321 mold C 0067 PROITE V11 322 mold C 0070 This SOP table contains relevant information for the manufacturer In case you need his support you might be asked to give the SOP number referring to the type of meter you bought K RoHS COMPLIANT eri 2002 95 EC DMMetering 2011 12 For the SOP number see section 15 PRO1 V11 xxx
4. RED LED Pulse output rate Data store lt 75 lt 95 25 C 55 C 25 C 55 C EN 50470 1 and 50470 3 1 IP51 IT PRO1D PROITE series 230V AC 195 253V AC 4kV for 1 minute 6kV 1 2uS waveform 5A 45A 0 4 Ib Imax 30Imax for 0 01s 50Hz 10 lt 2W Phase lt 10VA Phase 1000 or 2000 imp kWh see section 0 1000 or 2000 imp kWh see section 0 The data can be stored for more than 10 years without power For the SOP number see section 15 PRO1 V11 xxx 7 Basic errors 0 05Ib Cos 1 1 5 O 1Ib Cos 0 5L 1 5 Coso 0 8C 1 5 O 1Ib Imax Cos 1 1 0 O 2Ib Imax Cos 0 5L 1 0 Coso 0 8C 1 0 8 Description A Display register B Case C Protection cover D Security wire slot Material Register PC flame resistant plastic Case ABS flame resistant plastic Terminal block ABS flame resistant plastic Protection cover ABS flame resistant plastic B P d J J 120 C Note the image on the right might slightly differ from the type you have bought D DMMetering 2011 7 For the SOP number see section 15 PRO1 V11 xxx 9 Dimensions Height 120 mm Height without protection cover 92 mm Width 18 mm Depth 63 5 mm Size of the connection clamps 4x4mm Weight 0 08 kg net 10 Torque tables rm e p E e O 0 Oo ome m O s mO O osoon 0 0 o ona a a Se nwy a m amooo 11 Installation CAUTION e Turn off and if possible lock all sources supplying the
5. egulations e This meter can be installed indoor or outdoor enclosed in a meter box which is sufficiently DMMeteringg 2011 8 For the SOP number see section 15 PRO1 V11 xxx protected in accordance with local codes and regulations e To prevent tampering an enclosure with a lock or a similar device can be used e The meter has to be installed against a fire resistant wall e The meter has to be installed in a well ventilated and dry place e The meter has to be installed in a protective box if the meter is exposed to dust or other contaminants e The meter can be installed and used after being tested and can be sealed afterwards e The device can be installed on a 35mm DIN rail e The meter should be installed on a location where the meter can be read easily e In case the meter is installed in an area with frequent surges for example due to thunderstorms welding machines inverters etc the meter is required to be protected with a Surge Protection Device e The device should be sealed immediately after installing it in order to prevent tampering e Connection of the wires should be done in accordance with the connection diagram as shown below 1 phase line in L IN 3 phase line out L OUT 4 neutral line in N 6 2 neutral line out N O and 21 Pulse output contact SO 12 Operation 12 1 Consumption indication There is a red LED on the front panel which indicates the consumption measured by the meter Whe
6. energy meter and the equipment that is connected to it before working on it Always use a properly rated voltage sensing device to confirm that power is off WARNING e The installation should be performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to install the device A fuse thermal cut off or single pole circuit breaker should be fitted on the supply line and not on the neutral line e The connecting wire connecting the device to the outside circuit should be sized in accordance with local regulations for the maximum amount of the current breaker or other overcurrent protection devices used in the circuit e An external switch or a circuit breaker should be installed on the supply wires which will be used to disconnect the meter and the device supplying energy It is recommended that this switch or circuit breaker is placed near the meter because that is more convenient for the operator The switch or circuit breaker should comply with the specifications of the building s electrical design and all local regulations e An external fuse or thermal cut off used as an overcurrent protection device for the meter must be installed on the supply side wires It s recommended that this protection device is also placed near the meter for the convenience of the operator The overcurrent protection device should comply with the specifications of the building s electrical design and all local r
7. iorpier rin rr EEEE a aA 11 14 Ocna GUID DOM Ge rirse A EA AAA AE A E EAA 12 1D SOP PDO e E 12 DMMetering 2011 2 For the SOP number see section 15 PRO1 V11 xxx 1 Safety instructions Information for your own safety This manual does not contain all of the safety measures for operation of this meter because special operating conditions local code requirements or local regulations may necessitate further measures However it does contain information which must be adhered to for your own personal safety and to avoid material damage This information is highlighted by a warning triangle with an exclamation mark or a lightning bolt depending on the degree of actual or potential danger Caution This means hazard of electric shock and failure to take the necessary safety Warning This means that failure to observe the instruction can result in death serious injury or considerable material damage A precautions will result in death serious injury or considerable material damage Qualified personnel Installation and operation of the device described in this manual may only be performed by qualified personnel Only people that are authorized to install connect and use this device who have the proper knowledge about labeling and grounding electrical equipment and circuits and can do so in accordance with local safety regulations are considered qualified personnel in this manual Use for the intended purpose This device may only be
8. ld only be performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to maintain or repair the meter Make sure the protection cover is in place after maintenance or repair The case is sealed failure to observe this instruction can result in damage to the meter Problem Check Solution The red There is no load Connect a load to the meter consumption LED is not flashing PULSE LED The register doesn t count DMMetering 2011 connected to the meter The load on the line is very low There is a fault inside the meter There is almost no load connected to the meter iS a the Maybe there fault inside meter 11 Check with an Ohm meter if the load value is very low If the checks above don t solve the problem please contact technical support for a meter replacement Check if the red consumption LED is flashing 100 200 flashes of the LED at 1000 2000 pulses per kWh equals 0 1kWh Please contact technical support for a meter replacement For the SOP number see section 15 PRO1 V11 xxx Problem Check solution No pulse output The pulse output is Check the external voltage source not supplied with Ui is 5 27V DC with a voltage DC power meter The pulse output is Check if the connection is correct not connected the 5 27V DC should be correctly connected to the collector connection pin 20 and the signal wire S
9. n power is consumed the LED will flash The faster the LED flashes the more power is consumed For this meter the LED will flash 1000 or 2000 times per kWh see section 0 Please take note of the following the meter has a green backlight which can also be seen near the red LED please don t get confused 12 2 Reading the meter The PRO1 series meter can be delivered with either a digital or mechanical register See the version numbering in section 1 3 12 3 Mechanical register The PROITE series energy meter is equipped with a mechanical 5 1 register which is used to record consumption and can t be reset to zero Five decimals are marked with white color and one decimal is marked with red The reading accuracy is 1 10 kWh For this meter the LED will flash 1000 or 2000 times per kWh depending on the version of the meter see section O for details DMMeteringg 2011 9 For the SOP number see section 15 PRO1 V11 xxx 12 4 Digital register The PRO1D series energy meter is equipped with a 5 2 digit LCD which is used to record consumption and can t be reset to zero The display has 5 digits before and 2 decimals after the dot on the display The reading accuracy is 1 100 kWh For this meter the LED will flash 1000 or 2000 times per kWh depending on the version of the meter see section O for details 12 5 Pulse output The energy meter is equipped with a pulse output which is optically isolated from the inside circuit It genera
10. ng BV member of the Inepro Group Other names appearing in this manual may be trademarks of third parties and are property of their respectful owners 2 Foreword Thank you for purchasing this energy meter Inepro has a wide product range of devices We have introduced a large number of energy meters on the market suitable for 110V AC to 400V AC 50 or 60Hz Besides the normal energy meters we also developed our own pre paid meters with chip card chip card re loaders and a complete PC management control system For more information on other products please contact our sales department at sales ineprometering com or visit our website at www ineprometering com Although we produce this device according to international standards and our quality inspection is very accurate it s still possible that this device shows a defect or failure for which we do apologize Under normal conditions your product should give you years of trouble free operation In case there is a problem with the energy meter you should contact your distributor immediately Most of our energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim any warranty Therefore NEVER open an energy meter or break the seal of the device The warranty period is 3 years after production and only valid for production faults 3 Type number table The PRO1 series is labeled as follows PROID TEV11 xxx L Pulse led and pulse output 1 1000 im
11. or allow physical impact to the meter as there are high precision components inside that may break and affect the meter measurement negatively All clamps should be properly tightened Make sure the wires fit properly in the connection clamps If the wires are too thin it will cause a bad contact which can spark causing damage to the meter and its surroundings DMMeteringg 2011 3 For the SOP number see section 15 PRO1 V11 xxx Exclusion of liability We have checked the contents of this manual and every effort has been made to ensure that the descriptions are as accurate as possible However deviations from the description cannot be completely ruled out so that no liability can be accepted for any errors or omissions in the information given The data in this manual are checked regularly and the necessary corrections will be included in subsequent editions If you have any suggestions please do not hesitate to contact US Subject to technical modifications without notice Copyright Copyright Inepro Metering June 2011 All rights Reserved It is prohibited to pass on or copy this document or to use or disclose its contents without express permission of Inepro Metering BV Any duplication is a violation of the law and subject to criminal and civil penalties All rights reserved particularly for pending or approved patent awards or registered trademarks Registered trademarks DMMetering is a registered trademark of Inepro Meteri
12. pulses kWh 2 2000 impulses kWh Reverse counting 1 Does not count when energy is reversed 2 Counts up regardless of energy direction Type of display 1 LCD without backlight PRO1D 2 LCD with backlight PRO1D 3 Mechanical register PROITE DMMeteringg 2011 4 For the SOP number see section 15 PRO1 V11 xxx 4 MID certificate KEMAX CERTIFICATE EC Type examination certificate 6319 10 Manufacturer Contact person Address Postal code Place Country Instrument Mark Type Register Accuracy Class Measurement range Temperature range Use Protection Class Environmental class Registry method Inepro Metering BV D van der Vaart P O Box 92 2450 AB Leimuiden The Netherlands Electronic single phase two wire energy meter Direct connected PRO 1TE PRO1D Mechanical LCD 230 V M1 E2 bidirectional method with always positive register the meter always counts the energy l of the measuring point as received energy irrespective of the real energy direction The energy meter meets the requirements of Directive 2004 22 EC of the European parliament and the council of 31 March 2004 on measuring instruments Certification was based on compliance with the following harmonised standards EN 50470 1 2006 Electricity metering equipment a c part 1 General requirements tests and test conditions Metering equipment class indexes A B and C EN 50470 3 2006 Electricity metering equipment a c
13. tes pulses in proportion to the measured consumption for purpose of remote reading or accuracy testing The pulse output is a polarity dependent open collector transistor output requiring an external voltage source for correct operation For this external voltage source the voltage Ui should be lower than 27V DC The maximum switching current Imax is 27mA To connect the impulse output connect 5 27V DC to connector 20 collector and the signal wire S to connector 21 emitter The pulse output depends on the version and is either 1000 or 2000 impulses per kWh See section O for details regarding the impulses per kWh 20 Al 21 pin 21 emitter 20 pin 20 collector A 7 light bundle from the LED DMMeteringg 2011 10 For the SOP number see section 15 PRO1 V11 xxx 13 Troubleshooting A CAUTION During repair and maintenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other conducting material as that will cause an electric shock and possibly cause injury serious injury or even death Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before opening the protection cover and working on it Turn off and lock all power supply to the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock A WARNING Maintenance or repair shou
14. used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by Inepro Metering B V Proper handling The prerequisites for perfect reliable operation of the product are proper transport storage installation and connection as well as proper operation and maintenance During its operation certain parts of the meter might carry dangerous voltages Only use insulated tools suitable for the voltages this meter is used for Do not connect while the circuit is connected to a power or current source Only place the meter in a dry environment Do not mount the meter in an explosive area or exposed to dust mildew and or insects Make sure the used wires are suitable for the maximum current of this meter Make sure the AC wires are connected correctly before activating the current voltage to the meter e Do not touch the meter s connection clamps directly with your bare hands with metal blank wire or other conducting material as you will risk an electric shock that could cause possible injury serious injury or death e Make sure the protection covers are replaced after installation Maintenance and repair of the meter should only be carried out by qualified personnel e Never break any seals if present on this meter to open the front cover as this might influence the functionality or accuracy of the meter and will void all warranty e Do not drop
Download Pdf Manuals
Related Search
Related Contents
boot hard-disk drive replacement instructions XEN Axis & Master Feature & Specs Manual User`s Manual Template Service Manual Préface Livre num Wiley Professional XML Development with Apache Tools: Xerces, Xalan, FOP, Cocoon, Axis, Xindice Dossier BU, LA RELÈVE フラットディスプレイスタンドカメラテーブル取扱説明書 Copyright © All rights reserved.