Home
User Manual and Installation Notes
Contents
1. Computer Testing amp Control Software 1 Hardware There are one USB device communication port and one RS 232 communication port for computer connection on the rear panel of the UT2000 3000 Series digital storage oscilloscope By connecting a host computer or control computer to any one of the two ports you can control the oscilloscope with the host from a remote location 2 Installing the driver Take the USB A B lead Connect one end to the USB terminal of the host and the other end to the USB Device terminal on the rear panel of the oscilloscope Power on the oscilloscope and turn on the oscilloscope s power Found New ardware will appear at the right bottom corner of the operating screen of the host as shown below L Found New Hardware UITZ000 UT3000 You will also see an icon prompt that says Found New hardware UT2000 3000 Series Digital Storage Oscilloscope ij Found New Hardware x UTZO000 3000 Series Digital Storage Oscilloscope A Found New hardware dialogue box will pop up in a little while as shown below All right reserved 2007 13 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Found Mew Hardware Wizard Welcome To the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CO or on the Windows Update Web site with pour p
2. the function is ON When the indicator lights off the function is OFF 3 Click the Data Transmission knob to turn it on When the indicator lights up the function is ON When the indicator lights off the function is OFF All right reserved 2007 11 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Note This process may take several seconds 4 Click the Function knob on the menu bar than select remote control The following screen will appear You can now control the oscilloscope EX Far Control MENU RUACONT Hearure F re ot or age Fann KE op Mayer sar l Display IM 1 11T Aut o VERTICAL HORIZONTAL TRIGGER a pl E VOLTS DIV sEc DIV Force E gt al LZ HELF Important The above screen will not display waveform Operation of this screen will be indicated in the oscilloscope 5 At the end of operation press CLOSE to close this screen To switch to USB connection follows the steps for USB connection stated above When you have finished all operations press CLOSE to switch off the UT2000 3000 Series Digital Storage Oscilloscope software then power off the oscilloscope and disconnect the USB lead and RS 232 power cord All right reserved 2007 12 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Chapter Three Installation guide for UT2000_ 3000 Series
3. Range adjustment Voltage range Time base range Real time Control Equipment selection Serial USB ON OFF when the indicator lights up the function is ON when the indicator lights off the function is OFF Data transmission when the indicator lights up the function is ON when the indicator lights off the function is OFF Transmission screen when the indicator lights up the function is ON when the indicator lights off the function is OFF Reverse Mathematic function Indicator on means reverse mathematic function is in process Indicator off means reverse mathematic function is not in process Mathematic function Select with the MATH option in the function menu in the menu bar Auto Refresh Set up the refresh time interval with the waveform refresh menu in the menu bar Refresh time Set up refresh time while performing auto refresh All right reserved 2007 8 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Chapter Two Operation Guide After reading Chapter One you may now have a basic understanding of how this system works The following are more specific instructions for using the software We recommend you to read this chapter carefully to familiarize with application Connect the RS 232 power cord or USB lead Turn on the oscilloscope and activate the UT2000 3000 Series Digital Storage Oscilloscope software Enter the following screen E3 Digital Gscil
4. UNI To Uni Trend Group Limited File UTG 001 Date October 24 2007 Draft 1 UNI T UT2000 3000 Series Digital Storage Oscilloscopes User Manual and Installation Notes Document No SYSC 0 070606 June 2007 All right reserved 2007 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Copyright Information 1 Uni Trend Group Limited All rights reserved 2 Products of the Company have been authorized or are pending approval for patents in the People s Republic of China 3 Information contained in this manual supercedes all information in previously published versions 4 The Company reserves the right to change specifications and prices Note UNI T is the registered trademark of Uni Trend Group Limited All right reserved 2007 2 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited UT2000_ 3000 Series Digital Storage Oscilloscopes Introduction The UT2000 3000 Series Digital Storage Oscilloscope software is written for UT2000 3000 Series digital storage oscilloscopes With this software you can carry out communication between a computer and an oscilloscope through serial or USB and in turn perform remote control This software also provides testing waveform and sampling data reading functions to facilitate further signal testing and analysis Equipment Requirement Minimum Oscilloscope UT2000_ 3000 S
5. age of the wizard If you wish to stop the installation click Cancel once during any stage of the wizard to quit 3 Running the Software There are two ways to find this software and run it on your computer UTZO000 S000 m VI 1 After finishing installation a shortcut icon appears on your desktop Double click this icon to run the computer testing amp control software 2 Alternatively find the software in All Programs P in the Start Menu Select the computer testing amp control software and run Set Program Access and Defaults Windows Catalog Windows Update Accessories Games Documents Startup WinRAR amp Internet Explorer Search A msn k Outlook Express c Remote Assistance A windows Media Player a windows Messenger AN windows Movie Maker Programs Settings Help and Support Run S Uninstall UT2000_3000 v1 Turn OFF Computer fe UTZ000_3000 VI Log OFF Administrator E Mew Text Document del My Pictures All right reserved 2007 27 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Chapter Four System Prompts and Troubleshooting System Prompts Time out prompt Check the serial configuration or check whether the equipment is properly connected Time out prompt Check the USB configuration or check whether the equipment is properly connected SCAN prompt SCAN will perform single transmission Please car
6. al Storage Oscilloscopel 2000 Storage Gscilloscopelxp Setup Application Setup Application Note 1 The Ultra scope for UT2000 3000 Computer Testing amp Control Software installation kit downloaded online must first be unzipped 2 This software supports Windows 2000 and Windows XP Step 2 Begin installation The software installation wizard pops up as shown below 0UT2000_3000 FI Setup 4 ss k N T Helcome elcome to the installer for UTZ000 3000 VI 1 0 It is strongly recommended that you exit all Windows programs before continuing with this installation If you have any other programs rumning please click Cancel close the programs and run this setup again Otherwise click Hext to continue lt Back All right reserved 2007 22 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Step 3 Confirm that you wish to install this software Click the Next button UT2000 3000 FI License Agreement Please read the following license agreement carefully Insert your license agreement text here LS I agree to the terms of this license agreement I do not agree to the terms of this license agreement Step 4 Read the installation licensing agreement carefully Select I agree with the terms and conditions of the licensing agreement then click Next amp 012000 3000 TI User Information Enter your u
7. eries PC IBM compatible PC Windows 2000 XP OS 16MB RAM 4X optical drive or better SVGA display or better RS 232 Power Cord The connection terminals of the oscilloscope and PC must match USB Lead All right reserved 2007 3 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI Ts Uni Trend Group Limited Chapter One Software Structure Basics ccc ccc cece cece eee easeeesseeeees NOES On Operation INEM ACE X Za aE RL H RNA ATR RN es duped i NO e e sne IVe Ee G TT Chapter Two Operation Guide sirepna en nE EE EE LSR Oeae controls icedaswasvancdcucduvadaidbed Sa a a Heed Maw aa a a a r El Serial interface controls 0 0c cc cc ccc cece ccc cececencncececeuececeucucecececusssesesees Chapter Three Installation guide for UT2000 3000 Series Computer Testing amp Control Software ccccccc ccc c ence ence eee nee nee le AVS T D2 AMSA TAS dver x4 kadai eles a behage near ecdanie weed aeehaaee Ss ETIE the SOMWALC TTT Chapter Four System Prompts and Troubleshooting eee SYSEL PIONS sierran i aa Er t Krala T All right reserved 2007 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Chapter One Software Structure Basics Notes on operation interface EJ DER mL Gerililogcepe Furtusal Panel Toltage Sealing Tike 368156 L lad TT EL aa CP Class Rew a Cantal Channel Sisti
8. ermission Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device O No not this time Click N evt to continue c Back Next gt Set up as follows Step 1 Select Yes this time only and click Next once Step 2 In the Found New hardware Wizard wizard select Install from a list or specific location Advanced then click Next Found Mew Hardware Wizard This wizard helps you install software for UT 2000 3000 Seres Digital Storage Oscilloscope C If your hardware came with an installation CD ye or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended Install from a list or specific location Advanced Click Mest to continue All right reserved 2007 14 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited The following screen will appear Select Browse In the popped up Browse Folder box select the DSO directory in the directory where you intend to install UT2000_ 3000 then click Next As shown below Hardware Update Wizard Please choose your search and installation options LS Search for the best driver in these locations Use the check boses below to limit or expand the default search which includes local paths and removable media The best driwer found will be insta
9. esting amp Control Software UNI To Uni Trend Group Limited Click OK again to confirm Document copy will continue Found New Hardware Wizard Please wait while the wizard installs the software z UT 2000 3000 Seres Digital Storage Oscilloscope D UAI T sys To CAWINDOWS Systemae Drivers Back Next gt Cancel Click Finish to complete installation of the driver Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for UT 2000 3000 gt enez Digital Storage Oscilloscope Click Finish to close the wizard Back Cancel All right reserved 2007 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software 18 UNI To Uni Trend Group Limited At the right bottom corner of the screen you will see p 1 Found New Hardware x Your new hardware is installed and ready to use Display of the Device Manager is as follows Device Manager File Action View Help e Z K ep Disk drives a Display adapters IR Human Interface Devices IDE ATAJATAPI controllers Keyboards Mice and other pointing devices Monitors 89 Network adapters Other devices 9 Ports COM amp LPT ae Processors S Sound video and game controllers ra System devices Universal Serial Bus controllers SIS 7001 PCI to USE Open Host Controller SIS 7001 PCT to USE Open Host Controller SIS PCI
10. form time interval setup Help Content About Notes on front panel Channel status Current status of the oscilloscope is displayed When transmitting data this status bar displays the current status When the oscilloscope s status changes so will this status bar but you cannot use this bar to control the current status of the oscilloscope iF CH1 Coupling method DC AC GND Bandwidth suppression On Off Filter type low pass high pass band pass band stop Digital filter when the indicator lights up the function is ON when the indicator lights off the function is OFF Reverse when the indicator lights up the function is ON when the indicator lights off the function is OFF Probe 1X 10X 100X 1000X CH2 Coupling method DC AC GND Bandwidth suppression On Off Filter type low pass high pass band pass band stop Digital filter when the indicator lights up the function is ON when the indicator lights off the function is OFF Reverse when the indicator lights up the function is ON when the indicator lights off the function is OFF Probe 1X 10X 100X 1000X All right reserved 2007 7 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited 3 Sampling method Random Real time SCAN 4 Interpolation Yes NO 5 Current activated channel MATH CH1 CH2 Channel selection CH1 CH2 MATH Deviation factor adjustment Vertical Horizontal
11. he document is copied Hardware Update Wizard Please wait while the wizard installs the software UT 20007 3000 Seres Digital Storage Oscilloscope C7 Setting a system restore point and backing up old files in case your system needs to be restored in the future TI cu F b ci H All right reserved 2007 16 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited The following screen will appear while the document is being copied Hardware Update Wizard Please wait while the wizard installs the software Files Needed L The file UAI T sus on UNI T Digital Storage a Oscilloscope i needed Cancel Type the path where the file ts located and then click OF Copy files from C Frogram d O RETS Ho YGASUYGA3_ AP 38043 BULD GOWIN Pes JH GASU GAS 2P 38043 BOLO G0 WINKP_ 2k Click the left arrow of Browse to select the directory you have defined in Step 2 If you have not defined any find one in Browse Hardware Update Wizard Please wait while the wizard installs the software Files Needed H The file UNI T sys on UNI T Digital Storage Oscilloscope ts needed ms Cancel Type the path where the file ts located and then click OF Copy files from Browse c Back Next gt Cancel All right reserved 2007 17 User Manual for UT2000_ 3000 Series Computer T
12. lled Search removable media floppy CD ROM Include this location in the search C Program Files O50 we Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware Step 3 Enter the search in progress waiting screen Hardware Update Wizard Please wait while the wizard searches UT 2000 0 T3000 Cancel All right reserved 2007 15 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited The dialogue box below will appear but it will not affect the software or your computer Click Continue Anyway Hardware Update Wizard et Hardware Installation A The software you are installing for this hardware UT2000A000 Series Digital Storage Oscilloscope has not passed Windows Logo testing to very its compatibility with Windows amp P Tellme why this testing 15 important Continuing your installation of this software may impair or destabilize the corect operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation The system will automatically jump to the System Restore Setup screen and t
13. loseoepe Virtual Panel Channel L IW 498 0 R EAZ 5 h Seale Bath Voltage Sealing Time Scaling Clase Aete treck Close bhannal Status H aa Limit i Filtering inversion Rands j l zt Pate lt A kad S a C1 ee a oe eo iiis Interface Fr Ghe Filtering Inversion Interpolation Je J6 Pr Gede USB Interface Controls If controlling the oscilloscope via the USB interface follow the steps below 1 With the equipment selection knob on the real time control panel select USB 2 Click the Equipment ON OFF knob to turn it on When the indicator lights up the function is ON When the indicator lights off the function is OFF 3 Click the Data Transmission knob to turn it on When the indicator lights up the function is ON When the indicator lights off the function 1s OFF 4 Click the Data Transmission knob to turn it off When the indicator lights up the function is ON When the indicator lights off the function is OFF All right reserved 2007 9 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited 5 Click the Data Interface knob to pop up the following screen EJ Far Control N Pos U LKS BRY VERTICAL BORI ZONTAL TRIGGER Language Engish Ment N 1 T es N mck J 1 Tr 8 1 6 Click Series on the above screen so the oscilloscope can transmit continuously as indicated below You can now control the oscill
14. nt select Quick installation for the current user only or Make quick installation applicable to all users then click Next once UT2000 3000 FI Ready to Install You are now ready to install WIZ000 3000 YT 1 0 The installer now has enough information to install UTZU00 3000 YI on your computer The following settings will be used Install folder C Program Files UT 2000 3000 I shortcut folder UTZO000_ 3000 YI Please click Next to proceed with the installation All right reserved 2007 Zo User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Step 8 After confirming all information is correct click Next once UI2000_3000 FI Setup Installing UIZO00_3000 FI Please wait Installing Files C WINDOWS system32 evirteibintevirte rse Step 9 The successful installation screen appears amp 012000 3000 FI Installation Successful The M2000 S000 VI 1 0 installation is complete Thank you for choosing UTZ000_ 3000 VI Please click Finish to exit this installer Finish All right reserved 2007 26 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Step 10 When installation is complete as shown above click Finish F once on the screen The software has been installed in your host If you wish to change any setup simply click Back B once during any st
15. oscope EQ Far Control as BER a P Be asure Acqaire E 99 are O paree RESEO Ras N Pes DUS cy S Conrs 1 Cur sr spl rians I L 4 Lomnguage Eng bch VOLTS DIV SEC DTV iea 1 mer fa a fe Series C Single 7 When operation is complete press CLOSE to close this screen Note When starting step 5 after completing step 4 you can select Function and then Remote Control in the menu bar instead of clicking Data Interface The following screen will pop up to allow control of the oscilloscope but no waveform is displayed This operation is similar to Serial Interface Controls explained below All right reserved 2007 10 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Fa Par Control MERU ROUNCONT Measure Acquire ELETE T a l eee Conran K LZ Cursor Disp ay D VERTICAL HORIZONTAL TRIGGER ao K Y z7 Ta _ ZERO ope MERU Lae WOLTS O1 ERC DL wer a m al gt Serial Interface Controls Follow the following steps 1 Select Serial with the equipment selection knob of the real time control panel The following screen appears 3 Serial Port Setup When tranzmiting by serial port interface only have single fresh Serial Port Baud Rate COML oF 4800 Press OK 2 Click the Equipment ON OFF knob to turn it on When the indicator lights up
16. r B File Action wiew Help RI na P ALMA i Display adapters Ha Human Interface Devices IDE ATAJATAPI controllers keyboards 1 Mice and other pointing devices 72 Monitors gt Tl RIE E8 Network adapters Gh Other devices Gt PCI Device 9 Ports COM amp LPT 4 Processors D Sound video and game controllers 6 System devices Universal Serial Bus controllers siS 7001 PCT to USB Open Host Controller SIS 7001 PCT to USB Open Host Controller SIS PCT to USE Enhanced Host Controller USB Root Hub USB Root Hub USB Foot Hub UT 200 ge Update Driver Launches the Hardware Disable ce UE E E E 4 Uninstall Scan For hardware changes Properties All right reserved 2007 20 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited 3 Installing the software You can install from the installation CD Rom supplied with the oscilloscope or download the computer software directly from the UNI T website Step 1 Find the suitable operating system UT2000 3000 VI For WinXP or UT2000 3000 VI For Win2000 folder in the supplied CD Rom or unzipped path As directed by the operating system installation software double click the Setup icon as shown below All right reserved 2007 21 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited UT2000_ 3000 Series Digit
17. ry out single refresh Continue Are you sure you want to exit Virtual Instrument A prompt will ask you if you wish to close the software Troubleshooting 1 If the system prompts you to check serial or USB configuration when you enter Equipment ON OFF take the following steps Check whether the oscilloscope power plug is properly connected Check whether oscilloscope ports match the testing and control software setups Factory default RS 232 baud rate 4800 Check whether the cable connection between module and PC 1s in order After carrying out the above checks restart the software to continue operation OOH QO All right reserved 2007 28 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI Ts Uni Trend Group Limited Copyright Statement Uni Trend Group Limited owns copyright of this User Manual Unless with prior written authorization from the company no individual or firm may release publish or change any contents contained in any way whatsoever Thank you All right reserved 2007 29 User Manual for UT2000 3000 Series Computer Testing amp Control Software
18. ser information and click Hext to continue All right reserved 2007 23 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Step 5 Enter your user name and company name then click Next once 2 0T2000 3000 FI Installation Folder Where would you like UTZ000_ 3000 YI to be installed The software will be installed in the folder listed below To select a different location either type in a new path or click Change to browse for an existing folder Install UTZU00_3000 YI to C Program Files UTZ000 3000 YT Space required 15 1 ME Space available on selected drive 12 34 GB Step 6 Enter the installation path in the installation path field or click Change H to select an alternative installation path Then click Next once 012000 3000 FI Shortcut Selection there would you like the shorteuts to be installed The shortcut icons will be created in the folder indicated below I you don t want to use the default folder you can either type a new name or select an existing folder from the list Shorteut Folder UTZO00_ 3000 YT Ww Le Install shorteuts for current user only C 7 Make shortcuts available to all users All right reserved 2007 24 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Step 7 Depending on your specific requireme
19. t Filtering imver zien GS L ae 9 i l inir Faret ors Biteap interface Probe USA 1 1 1 Filtering Inverzicn aati d d d ee Je 6 TE Piss Notes on menu l Document Load waveform save waveform load intersection print preview print preview print exit 2 Function Mathematics function User can select the calculation method of the channels or window function fa Nath Operation FFT Window Functions Rectangle kd Source All right reserved 2007 5 User Manual for UT2000 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Remote control Control of the serial interface can be performed from a remote point Fl Far Cnt re Ed RUA T ar a Run Sf op Litt seqaire Starag alee Unility Auta WERT ICAL BORD SURTAL TRIGGER D a S ise L ZERS es soias ns sec pry FoR Data form How the voltage changes with time EJ Data Table Funetion Wave Data of CHI b ma ica SS ja SS S P EE o i E All right reserved 2007 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited Parameter testing The current parameters are displayed 2 4 fi Parameter Measurement Ea Function Start Pauze Refresh waveform single refresh wave
20. to USE Enhanced Host Controller USE Root Hub USE Root Hub USE Foot Hub UTZ000 3000 Series Digital Storage Oscilloscope Note If no Found New Hardware wizard pops up on your computer screen when the computer is properly connected to the oscilloscope and the latter 1s powered on normally right click My Computer and select Attribute In the System Attribute dialogue box select the Hardware box Click the Device Manager button In the pop up Device Manager dialogue box you can see a yellow UT2000 3000 icon that indicates incomplete installation All right reserved 2007 19 User Manual for UT2000_ 3000 Series Computer Testing amp Control Software UNI To Uni Trend Group Limited 4 Device Manager File Action View Help e Z Display adapters Ba Human Interface Devices IDE ATA ATAPI controllers Keyboards 1 Mice and other pointing devices 72 Monitors E8 Network adapters Gk Other devices EE PCI Device Ports COM amp LPT ee Processors D Sound video and game controllers System devices L Universal Serial Bus controllers SIS 7001 PCI to USB Open Host Controller SIS 7001 PCI to USB Open Host Controller SIS PCT to USB Enhanced Host Controller USE Root Hub USE Root Hub USE Root Hub UTZO0O UT2000 E E Right click your mouse and select Update Driver Application to pop up the Found New Hardware wizard Follow step 1 to install the driver Device Manage
Download Pdf Manuals
Related Search
Related Contents
Supervisor and Fritz! modem Legal Case Management for not-for-profit organisations User`s manual 客室管理機 Télécharger un extrait - Editions Bouchard Mathieux Clase S221 vrs-7200 mode d`emploi BOSE L1 Model I Manuale Utente MEGA-MIG 300 RVS Constant Voltage Type Rectifier Welding manual de instruções do alicate digital modelo ad-7100 Copyright © All rights reserved.
Failed to retrieve file