1. Ground yourself before touching any component 2 3 Symbol on the Product Symbol Explanation Danger to life due to electric shock The product operates at high voltages All work on the product must be carried out by qualified persons only 8 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 3 Scope of Delivery 3 Scopeof Delivery Check the scope of delivery for completeness and any externally visible damage Contact your distributor if the scope of delivery is incomplete or damaged A Figure 1 Components included in the scope of delivery Position Quantity Description A 1 Multifunction relay B 1 M20x1 5 cable gland G 1 Installation manual D MA4x8 cylindrical screw E 1 Washer M4 This component is not included if the multifunction relay is installed upon delivery Installation Manual MFR NR IA en 22 9 4 Electrical Connection SMA Solar Technology AG 4 Electrical Connection 4 1 Safety during Electrical Connection DANGER Danger to life due to high voltages of the PV array When exposed to sunlight the PV array generates dangerous DC voltage which is present in the DC conductors and the live components of the inverter Touching the DC conductors or the live components can lead to lethal electric shocks All work on the inverter must be carried out by qualified persons only Prior to performing any work on the inverter always disconnect the inverter from all voltage sources
2. 23 Changing the Operating Mode of the Multifunction Relay 26 Technical Data ccc cc eee cece cece e nnn 27 CONOC co oe he es Si a diae ee a ER a dto 28 EC Declaration of Conformity 30 Installation Manual MFR NR IA en 22 3 Table of Contents SMA Solar Technology AG 4 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Information on this Document 1 1 Validity This document is valid for device type MFRO1 10 1 2 Target Group The activities described in this document must only be performed by qualified persons Qualified persons must have the following skills Knowledge of how an inverter works and is operated Training in how to deal with the dangers and risks associated with installing and using electrical devices and installations Training in the installation and commissioning of electrical devices and installations Knowledge of the applicable standards and directives Knowledge of and compliance with this document and all safety information 1 3 Symbols Explanation Symbol A DANGER Indicates a hazardous situation that if not avoided will result in death or serious injury A WARNING Indicates a hazardous situation that if not avoided can result in death or serious injury A CAUTION Indicates a hazardous situation that if not avoided can result in minor or moderate injury raoa T deseada nace T damage
3. Installation Manual MULTIFUNCTION RELAY Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these documents is the property of SMA Solar Technology AG Any publication whether in whole or in part requires prior written approval by SMA Solar Technology AG Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not require prior approval SMA Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All trademarks are recognized even if not explicitly identified as such Missing designations do not mean that a product or brand is not a registered trademark The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of these marks by SMA Solar technology AG is under license Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Organization Inc QR Code is a registered trademark of DENSO WAVE INCORPORATED Phillips and Pozidriv are registered trademarks of Phillips Screw Company Torx is a registered trademark of Acument Global Technologies Inc SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E mail infoGSMA de 2004 until 2015 SMA Solar Technology AG All rights reserved 2 MFR NR IA en 22 Installation Manual SM
4. Use an Allen key AF 3 7 Flip the display assembly down 8 Tighten the screw of the display assembly 9 Insert the plug from the multifunction relay ribbon cable into the left hand pin connector on the display assembly You have to press apart the lock hooks on the pin connector in order to insert the plug I After inserting the plug the lock hooks close 18 MFR NR IA en 22 Installation Manual SMA Solar Technology AG A Electrical Connection 4 5 Selecting the Operating Mode i Error message required by standard In some countries signaling of errors is required by standards e g IEC 62109 2 In order to meet the standard requirement take one of the following measures Operate the multifunction relay in the operating mode Fault indication Fltlnd and connect a display to the multifunction relay that signals an error or the undisturbed operation of the inverter Activate the error alarm in Sunny Portal see the Sunny Portal user manual at www SunnyPortal com for information on receiving error alarms via Sunny Portal This requires the inverter to be registered in Sunny Portal You can choose between the following operating modes Operating mode of multifunction relay Mlt OpMod Fault indication FltInd Self consumption SelfCsmp Control via communication ComCtl Battery bank BatCha Fan control FanCtl Switching status grid relay GriSwCpy Installation Manual De
5. 6 Install the display Plug the ribbon cable plug into the pin connector on the display assembly Lead the display into the righthand retainer Lead the display into the left hand retainer 16 MFR NR IA en 22 SMA Solar Technology AG Installation Manual SMA Solar Technology AG 4 Electrical Connection 4 4 3 Installing the Multifunction Relay in the Sunny Boy Windy Boy or Sunny Tripower i Displayed graphics This section describes the installation of the multifunction relay but only shows the Sunny Tripower in the illustrations The procedure for installing the multifunction relay in Sunny Boy Windy Boy and Sunny Tripower inverters is identical Only the inverter environment is different Procedure 1 INNI Danger to life due to high voltages in the inverter Disconnect the inverter from all voltage sources and open the lower enclosure lid see inverter manual 2 Release the display assembly screw and flip the display assembly up 3 The display assembly snaps into place 4 Insert the multifunction relay in the inverter Lead the left hand key on the multifunction relay into the hole in the plastic retainer for the display assembly 5 Lead the ribbon cable upwards behind the display assembly Installation Manual MFR NR IA en 22 17 4 Electrical Connection SMA Solar Technology AG 6 Fasten the multifunction relay using the washer and the cylindrical screw torque 1 5 Nm
6. PASUA PERSON Indicates that the following section contains tasks that must be performed by qualified persons only Information that is important for a specific topic or goal but is not safety relevant Indicates a requirement for meeting a specific goal Desired result x s L A problem that might occur Installation Manual MFR NR IA en 22 5 SMA Solar Technology AG 1 Information on this Document 1 4 Typographies Typography Application Example bold Parameters Select the parameter Operating mode of Elements to be selected multifunction relay or Elements to be entered Mlt OpMode and set the desired operating mode 1 5 Nomenclature Complete designation Designation in this document Multifunction relay Multifunction relay product Sunny Boy Windy Boy Sunny Tripower Inverter Sunny Boy Smart Energy PV system small wind turbine system System 1 6 Display of Parameters Depending on the type of communication e g RS485 BLUETOOTH or Speedwire Webconnect the parameters and messages are displayed differently on the communication products This document uses both methods of displaying parameters Example Display of the parameter for setting the operating mode of the multifunction relay For communication via RS485 parameter Mlt OpMode For communication via BLUETOOTH or Speedwire Webconnect parameter Operating mode of multifunction relay 6 MFR NR IA en 22 Installation Manual SMA Sol
7. This determines the minimum time for which the load remains switched on 4 If you have set the operating mode Control via communication select the parameter Status of MER with control via communication MltComCtl Sw and set the desired value This determines the status used when the multifunction relay is controlled via a communication product 5 If you have set the operating mode Battery bank make the following additional settings Select the parameter Minimum On power for MER battery bank Blt BatCha Pwr and set the desired value This determines the power threshold at which the battery is supposed to be charged Select the parameter Minimum time before reconnection of MFR battery bank Blt BatCha Tmm and set the desired value This sets the minimum time which must elapse after charging the battery before battery charging can resume 26 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 6 Technical Data Maximum AC switching voltage Maximum DC switching voltage Maximum AC switching current Maximum DC switching current Minimum electrical endurance when the maximum switching voltage and maximum switching current are complied with Corresponds to 20 years at 12 switching operations per day Installation Manual 6 Technical Data 240 V 30 V 10A 10A 1 000 000 switching cycles MFR NR IA en 22 27 7 Contact 7 Contact If you have technical problems with our products please contact the SMA Service
8. attaching the multifunction relay in the inverter MFR NR IA en 22 11 4 Electrical Connection SMA Solar Technology AG 4 4 Installing the Multifunction Relay 4 4 1 Mounting Position and Cable Route Mounting Position and Cable Route in the Sunny Tripower A vu ZA D C Figure 3 Installation area and cable route in the Sunny Tripower with the lower enclosure lid open and the B display assembly flipped up Position Description A Inverter display assembly B Installation location of the multifunction relay C Cable route for the connection to the multifunction relay D M20x1 5 cable gland 12 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 4 Electrical Connection Mounting Position and Cable Route in the Sunny Boy Smart Energy MA VA e e o WANT N i Figure 4 Installation area and cable route in the Sunny Boy Smart Energy with the enclosure lid open and the display flipped up Position Description A Inverter display B Installation location of the multifunction relay C Cable route for the connection to the multifunction relay D M20x1 5 cable gland Installation Manual MFR NR IA en 22 13 4 Electrical Connection SMA Solar Technology AG Mounting Position and Cable Route in the Sunny Boy Windy Boy A Figure 5 Installation area and cable route i
9. operation If necessary GOMNecHon 0 I Light on toground Light on Trouble free Error F operation B Figure 6 Wiring diagram with several inverters for connection of an operation signaling contact and wiring diagram for connection of a fault indicator contact example Installation Manual MFR NR IA en 22 2 4 Electrical Connection SMA Solar Technology AG Controlling loads or charging external batteries in a power dependent way via the multifunction relay Loads can be controlled and external batteries charged in a power dependent way via the multifunction relay To enable this function a contactor K1 must be connected to the multifunction relay The contactor K1 switches the operating current for the load on or off If you want external batteries to be charged depending on the available power the contactor serves to activate or deactivate the charging of the batteries Circuit breaker 1 A N Figure 7 Wiring diagram for connection to control a load or for the power dependent charging of the batteries 22 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 4 Electrical Connection Reporting the switching status of the grid relay The multifunction relay can trip a signal to the grid operator as soon as the inverter connects to the utility grid To enable this function the multifunction relays of all inverters must be connected in parallel Inverter 1 Grid relay closed
10. see the inverter manual Do not touch any live components of the inverter NOTICE Damage to the inverter due to electrostatic discharge Touching electronic components can cause damage to or destroy the inverter through electrostatic discharge Ground yourself before touching any component 4 2 Electrical Connection Procedure Procedure See 1 Installation of the multifunction relay Install the multifunction relay in Section 4 4 page 12 the inverter if it is not installed in the inverter upon delivery 2 Selection of the operating mode Select the operating mode in Section 4 5 page 19 which you want to use the multifunction relay 3 Connection of the multifunction relay Connect the multifunction Section 4 6 page 20 relay based on the operating mode and the corresponding wiring diagram 4 Change of the operating mode Change the operating mode of the Section 5 page 26 multifunction relay if you do not want to operate the multifunction relay in the operating mode Fault indication Fltlnd and do not plan to connect a display to the multifunction relay 10 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 4 Electrical Connection 4 3 Overview of the Connection Area Figure 2 Design of the multifunction relay Position A B C Installation Manual Description Connecting terminal plate for the connection to the multifunction relay Ribbon cable for the connection in the inverter Hole for
11. A Solar Technology AG Table of Contents Table of Contents CON O O Information on this Document 5 DUMP nU TE TERT 5 122 GRE SlOUD su ist i o bebida O ARTE 5 li USWNIDOIS S douter ilaele 5 li Typographies sessi seresa r acta a aede a S CAR edet ie er E 6 LS Nomencialbie sa periti elia ak uba ee a i EE 6 1 6 Display of Parameters 2 sito tinello 6 SGIely siete reti 7 2x i ale 0 RE Li pat ione ini 7 22 Safy INIGIMGNON sortie 8 2 9 SyMDOl On NesPrOdUCh in uz r u ur seria banale 8 Scope of Delivery 9 Electrical Connection 10 4 1 Safety during Electrical Connection 10 4 2 Electrical Connection Procedure 10 4 3 Overview of the Connection Areq 1 4 4 Installing the Multifunction Relay 12 4 4 1 Mounting Position and Cable Route 12 4 4 2 Installing the Multifunction Relay in the Sunny Boy Smart Energy 15 4 4 3 Installing the Multifunction Relay in the Sunny Boy Windy Boy or SURBV DOWEL ru yy dto de Pm HE PSP p ten Sn 17 4 5 Selecting the Operating Mode 19 4 6 Connecting the Multifunction Reloy 20 4 6 1 Connection Options for the Multifunction Relay 20 4 6 2 Connecting to the Multifunction Reloay
12. Inverter 2 Grid relay open Inverter n Grid relay open O gt 1 Signal to Ve e O Do grid operator Figure 8 Wiring diagram for reporting the switching status of the grid relay example 4 6 2 Connecting to the Multifunction Relay Requirements O The technical requirements of the multifunction relay must be met see Section Technical Data page 27 Cable requirements Ll The cable must be double insulated External diameter 5 mm to 12 mm Installation Manual MFR NR IA en 22 23 4 Electrical Connection SMA Solar Technology AG Conductor cross section 0 08 mm to 2 5 mm O The cable type and cable laying method must be appropriate for the installation and location NOTICE Destruction of the multifunction relay as a result of excessive contact load Observe the maximum switching voltage and maximum switching current see Section Technical Data page 27 When connecting the multifunction relay to the utility grid protect the multifunction relay with a separate circuit breaker i Displayed graphics This section describes the connection to the multifunction relay but only shows the Sunny Tripower in the illustrations However the same method is used to connect to the multifunction relay in all the inverters Only the inverter environment is different Procedure 1 When connecting to the utility grid protect the multifunction relay with a separate circuit breaker 2 JW N
13. Line We require the following information in order to provide you with the necessary assistance Inverter device type e Inverter serial number Inverter firmware version Special country specific settings of the inverter if applicable Type and number of PV modules connected Mounting location and altitude of the inverter Inverter message Optional equipment e g communication products Application operating mode of the multifunction relay Danmark Germany Austria Switzerland Espana Portugal SMA Solar Technology AG Niestetal Germany SMA Online Service Center www SMA de Service Sunny Boy Sunny Mini Central Sunny Tripower 49 561 9522 1499 Monitoring Systems communication products 49 561 9522 2499 Fuel Save Controller photovoltaic diesel hybrid systems 49 561 9522 3199 Sunny Island Sunny Backup Hydro Boy 49 561 9522 399 Sunny Central 49 561 9522 299 SMA Ib rica Tecnolog a Solar S L Barcelona 34 935 63 50 99 28 MFR NR IA en 22 Belgium Belgique Belgi Luxemburg Luxembourg The Netherlands Cesko Magyarorsz g Polska Rom nia Slovensko E dda K rpog France SMA Solar Technology AG SMA Benelux BVBA SPRL Mechelen 32 15 286 730 SMA Central amp Eastern Europe s r o Praha 420 235 010 417 SMA Hellas AE AOnva 30 210 9856666 SMA France S A S Lyon 33 472 22 97 00 Installation Manual SMA So
14. ar Technology AG 2 Safety 2 Safety 2 1 Intended Use The multifunction relay is a multifunctional interface that can be configured for the operating mode used by a particular system see Section 4 5 Selecting the Operating Mode page 19 The multifunction relay can be retrofitted or installed in the inverter at the factory if specified in the order The multifunction relay is suitable for use in the following SMA inverters e SB 3000TL21 SB 3600TL 21 SB 4000TL 21 SB 5000TL21 SB 3600SE 10 SB 5000SE 10 WB 3000TL 21 WB 3600TL 21 WB 4000TL 21 WB 5000T1 21 e SB 2500TLST 21 SB 3000TLST 21 e STP 8000TL 10 STP 10000TL 10 STP 12000TL 10 STP 15000TL 10 STP 17000TL 10 e STP 15000TLHE 10 STP 20000TLHE 10 STP 15000TLEE 10 STP 20000TLEE 10 STP 20000TL 30 STP 25000TL 30 Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives Any other application may cause personal injury or property damage For safety reasons it is not allowed to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for the product Unauthorized changes and modifications will void all warranty claims and the operating permission Any use of the product other than that described in the Intended Use section does not qualify as the intended use The enclosed documentation is an integral part of this p
15. ed Danger to life due to high voltages in the inverter Disconnect the inverter from voltage sources see inverter manual 3 If the cable gland on the inverter is installed inside the inverter insert the cable gland from the outside Unscrew the counter nut from the outside of the inverter and remove the cable gland from inside of the inverter Insert the cable gland from the outside into the enclosure opening and tighten it from the inside using the counter nut 24 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 4 Electrical Connection 4 Slightly loosen the swivel nut of the cable gland and remove the sealing plug 5 Ifthe diameter of the connection cable is more than 8 mm remove the internal seal insert from the cable gland 6 Route the cable into the inverter through the cable gland 7 Dismantle the cable by no more than 15 mm 8 Strip off the conductor insulation by max 8 mm 9 Depending on the intended use operating mode connect the cable to the connecting terminal plate for connecting to the multifunction relay in accordance with the wiring diagram 10 Tighten the swivel nut of the cable gland 11 Flip the display down 12 For Sunny Tripower or Sunny Boy Windy Boy inverters Tighten the screw of the display assembly 13 Recommission the inverter see inverter manual Installation Manual MFR NR IA en 22 25 5 Changing the Operating Mode of the Mult
16. ifunction Relay SMA Solar Technology AG 5 Changingthe Operating Mode of the Multifunction Relay The default operating mode of the multifunction relay is Fault indication FltInd If you decide to use another operating mode and have established the correct electrical connection for this operating mode you will have to change the operating mode of the multifunction relay and make other settings if necessary see the communication product manual for more information on changing parameters Requirements L The inverter must be connected to a communication product via BLUETOOTH or Speedwire Webconnect Procedure 1 Call up the user interface of the communication product or Sunny Explorer and log in as Installer 2 Select the parameter Operating mode of multifunction relay Mlt OpMode and set the desired operating mode 3 Once you have set the operating mode Self consumption make the following additional settings Select the parameter Minimum On power for MER self consumption Mlt MinOnPwr and set the desired value This determines the power threshold at which a load is switched on Select the parameter Minimum power On time MFR self consumption Mlt MinOnPwrTmm and set the desired value This determines the minimum time for which the power must exceed the minimum switch on power threshold before the load is switched on Select the parameter Minimum On time for MFR self consumption Mlt MinOnTmm and set the desired value
17. ion of Conformity can be found at www SMA Solar com CE 30 MFR NR IA en 22 Installation Manual SMA Solar Technology
18. lar Technology AG 7 Contact Italia SMA Italia S r l United Kingdom SMA Solar UK Ltd Milano Milton Keynes 39 02 8934 7299 44 1908 304899 United Arab SMA Middle East LLC India SMA Solar India Pvt Ltd Emirates Abu Dhabi Mumbai 97 2 234 6177 91 22 61713888 reri SMA Technology Korea Co Ltd ng SMA Solar Thailand Co Ltd A NINIMNI 82 2 520 2666 66 2 670 6999 South Africa SMA Solar Technology Argentina SMA South America SPA South Africa Pty Ltd Brazil Santiago Cape Town Chile 562 2820 2101 08600SUNNY 78669 Per International 27 0 21 826 0600 Australia SMA Australia Pty Ltd Other countries International SMA Service Line Sydney Niestetal Germany Toll free for Australia 1800 SMA Toll free worldwide AUS 00800 SMA SERVICE 1800 762 287 800 762 7378423 International 61 2 9491 4200 Installation Manual MFR NR IA en 22 29 8 EC Declaration of Conformity SMA Solar Technology AG 8 EC Declaration of Conformity within the meaning of the EC directives e 2004 108 EC electromagnetic compatibility EMC 2006 95 EC Low voltage LVD 1999 5 EU Radio and Telecommunications Terminal Equipment R amp TTE SMA Solar Technology AG hereby declares that the assembly described in this document is in compliance with the essential requirements and other relevant provisions of the aforementioned directives when used as intended with inverters from the Sunny Boy and Sunny Tripower device families The complete EC Declarat
19. n the Sunny Boy Windy Boy with the lower enclosure lid open and the display assembly flipped up Position Description A Inverter display assembly B Installation location of the multifunction relay C Cable route for the connection to the multifunction relay D M20x1 5 cable gland 14 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 4 Electrical Connection 4 4 2 Installing the Multifunction Relay in the Sunny Boy Smart Energy 1 A DANGER Danger to life due to high voltages in the inverter Disconnect the inverter from voltage sources and open the enclosure lid see inverter manual 2 Removing the display Flip the display up Remove the plug of the display ribbon cable from the pin connector on the display assembly Flip the display down Press the righthand retainer outwards Pull the display out of the right hand retainer Pull the display out of the left hand retainer Set the display aside in a safe place Installation Manual MFR NR IA en 22 15 4 Electrical Connection 3 Insert the ribbon cable of the multifunction relay into the pin connector on the display assembly 4 Insert the multifunction relay in the inverter Lead the left hand key on the multifunction relay into the hole in the plastic retainer for the display assembly 5 Fasten the multifunction relay using the washer and the cylindrical screw torque 1 5 Nm Use an Allen key AF 3
20. roduct Keep the documentation in a convenient place for future reference and observe all instructions contained therein Installation Manual MFR NR IA en 22 7 2 Safety SMA Solar Technology AG 2 2 Safety Information This section contains safety information that must be observed at all times during work on or with the product To prevent personal injury and property damage and to ensure long term operation of the product read this section carefully and observe all safety information at all times A DANGER Danger to life due to high voltages of the PV array When exposed to sunlight the PV array generates dangerous DC voltage which is present in the DC conductors and the live components of the inverter Touching the DC conductors or the live components can lead to lethal electric shocks All work on the inverter must be carried out by qualified persons only Prior to performing any work on the inverter always disconnect the inverter from all voltage sources see the inverter manual Do not touch any live components of the inverter CAUTION Risk of burns due to hot inverter enclosure parts Some parts of the inverter enclosure can get hot during operation Do not touch any parts other than the lower enclosure lid of the inverter during operation NOTICE Damage to the inverter due to electrostatic discharge Touching electronic components can cause damage to or destroy the inverter through electrostatic discharge
21. scription The multifunction relay controls a display device which depending on the type of connection signals either an error or the undisturbed operation of the inverter This operating mode is set by default The multifunction relay switches the loads on or off depending on the amount of power available from the PV array If a battery is integrated in the system the multifunction relay will still switch the loads on or off depending on the amount of power available from the PV array not from the battery The multifunction relay switches loads on or off according to commands transmitted by a communication product The multifunction relay controls the charging of external batteries depending on the amount of power available from the system The multifunction relay controls an external fan depending on the temperature of the inverter If the temperature of the inverter is 5 C higher than a specific threshold set in the inverter the fan starts automatically If the temperature of the inverter is 10 C below the set threshold the fan stops automatically The multifunction relay switches simultaneously with the grid relay of the inverter and transmits a signal to the grid operator MFR NR IA en 22 19 4 Electrical Connection SMA Solar Technology AG 4 6 Connecting the Multifunction Relay 4 6 1 Connection Options for the Multifunction Relay There is a different connection procedure depending on which operating mode you selec
22. t Operating mode of Connection option multifunction relay Mlt OpMod Fault indication Fltlnd Using the multifunction relay as fault indicator contact Self consumption Controlling loads or charging batteries in a power dependent SelfCsmp way via the multifunction relay Control via communication Controlling loads or charging batteries in a power dependent ComCtl way via the multifunction relay Battery bank BatCha Controlling loads or charging batteries in a power dependent way via the multifunction relay Fan control FanCtl Connecting the external fan see fan documentation Switching status grid relay Reporting the Switching Status of the Grid Relay GriSwCpy Using the multifunction relay as a fault indicator contact or operation signaling contact You can use the multifunction relay as a fault indicator contact for displaying or reporting inverter errors This requires a parallel connection Alternatively you can choose to have the undisturbed operation displayed or reported This requires a series connection You can connect several inverters to one fault indicator or operation indicator You must connect the multifunction relays of several inverters in parallel 20 MFR NR IA en 22 Installation Manual SMA Solar Technology AG 4 Electrical Connection Operation message Error message or N Lor 2 or N Circuit breaker Circuit breaker 1 AJ Fault in the inverter Inverter in operation Inverter in