Contents
1. Accuracy Accuracy 1A to 100A AC 45 to 65Hz 2 reading 0 1A gt 65 to 500HZ 2 3 reading 0 1A Reference conditions 23 C 3 20 to 70 RH external magnetic field lt 40A m no DC component no external current carrying conductor test sample centered Load impedance 1MQ Frequency Range 45 to 500Hz Working Voltage 250V AC Common Mode Voltage 250V AC Calibration Check Recommended once a year MECHANICAL SPECIFICATIONS Operating Temperature 14 to 122 F 10 to 50 C Storage Temperature 40 to 176 F 40 to 80 C Maximum Cable Diameter 0 47 max 12mm Dimensions 1 26 x 4 53 x 0 87 32 x 115 x 22mm Weight 5 6 oz 160g Polycarbonate Material Handle 10 Fiberglass charged polycarbonate UL 94 VO Output MN103 Double reinforced insulated 5 ft 1 5m lead with safety 4mm banana plug SAFETY SPECIFICATIONS Electrical IEC 414 250V working voltage 250V max common mode between output and ground 3kV 50 60 Hz dielectric for 1 mn ORDERING INFORMATION AC Current Probe MN109 000cseeeeeeeeees Cat 1031 02 Accessories Banana plug adapter to nonrecessed plug Cat 1017 45 OPERATION Making Measurements with the AC Current Probe Model MN103 e Connect the black lead of the current probe to common and the red lead to the AC voltage range on your DMM or other voltage measuring instrument The 10A range has an out
2. maintenance use only original factory replacement parts e To avoid electrical shock do not attempt to perform any servicing unless you are qualified to do so e To avoid electrical shock and or damage to the instrument do not get water or other foreign agents into the probe Cleaning To ensure optimum performance it is important to keep the probe jaw mating surfaces clean at all times Failure to do so may result in error in readings To clean the probe jaws use very fine sand paper fine 600 to avoid scratching the jaw then gently clean with a soft oiled cloth REPAIR AND CALIBRATION You must contact our Service Center for a Customer Service Authorization number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T includes calibration certificate plus recorded calibration data Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive e Dover NH 03820 USA Tel 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 repair aemc com Or contact your authorized distributor Costs for repair standard calibration and calibration traceable to N I S T are available NOTE All customers must obtain a CSA before returning any instrument T
3. AC Current Probe Model MN103 User Manual DESCRIPTION The MN103 Catalog 1031 02 measures leakage current and low currents from 1 mA and measures current on 5A secondaries This current probe provides AC current measuring capabilities to instruments with mV inputs The Model MN103 offers a 5 ft lead with safety 4mm banana plug WARNING These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument Read the instruction manual completely and follow all the safety information before attempting to use or service this instrument Use caution on any circuit Potentially high voltages and currents may be present and may pose a shock hazard Read the safety specifications section prior to using the current probe Never exceed the maximum voltage ratings given Safety is the responsibility of the operator ALWAYS connect the current probe to the display device before clamping the probe onto the sample being tested ALWAYS inspect the instrument probe probe cable and output terminals prior to use Replace any defective parts immediately NEVER use the current probe on electrical conductors rated above 250V Use extreme caution when clamping around bare conductors or bus bars INTERNATIONAL ELECTRICAL SYMBOLS E This symbol signifies that the current probe is protected by double or reinforced insulation Use only factory specified replacement parts when servicing the instrument A Thi
4. ECHNICAL AND SALES ASSISTANCE If you are experiencing any technical problems or require any assistance with the proper use or application of this instrument please call our technical hotline 800 343 1391 508 698 2115 Fax 508 698 2118 Chauvin Arnoux Inc d b a AEMC Instruments techsupport aemc com en 09 AN 100019 v8 11 05
5. put signal of 1mV mA AC This means that for 10A AC in a conductor around which the probe is clamped 10V AC will come out of the probe leads to your DMM or instrument The 100A range has an output signal of 1mV A AC This means that for 100A AC in a conductor around which the probe is clamped 100mV AC will come out of the probe leads to your DMM or instrument Select the range on your DMM or instrument which corresponds best to the measured current If the current magnitude is unknown start with the highest range first and work down until the appropriate range and resolution is reached Clamp the probe around the conductor Take the reading on the meter and multiply it by the output signal used to obtain the measured current e g If the meter reads 100 5mV range 1mV mA then current equals 100 5mA AC Unclamp the probe from the conductor before disconnecting it from your DMM or instrument e For best accuracy avoid if possible the proximity of other conductors which may create noise Tips for Making Precise Measurements e When using a current probe with a meter it is important to select the range that provides the best resolution Failure to do this may result in measurement errors e Make sure that probe jaw mating surfaces are free of dust and contamination Contaminants cause air gaps between the jaws increasing the phase shift between primary and secondary It is very critical for power measurement MAINTENANCE Warning e For
6. s symbol signifies CAUTION and requests that the user refer to the user manual before using the instrument This is a type A current sensor This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted RECEIVING YOUR SHIPMENT Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage PACKAGING The AC Current Probe MN103 is shipped with this instruction manual and a product warranty and registration card Register online at www aemc com INSTRUMENT COMPATIBILITY The Model MN103 is compatible with any AC voltmeter multimeter or other voltage measurement instrument with an input impedance of 100kQ or greater To achieve the stated accuracy use the MN103 with a voltmeter having an accuracy of 1 or better J AEMC INSTRUMENTS 0 47 max 12 mm 1 26 32 mm 115 mm 4 53 ELECTRICAL SPECIFICATIONS Current Range low 10A 1mA to 10A AC Output Signal 1mV AC mA AC 10V 10A Accuracy Accuracy 1mA to 10A AC 45 to 65Hz 3 reading 1mA gt 65 to 500HZ 2 6 reading 1mA Current Range high 100A 1 to 100A AC Output Signal 1mV AC A AC 100mV 100A Load Impedance 100KQ min