Home

OCS-XS series crane scale user manual

image

Contents

1. XXXXXX shown The scale will be back to work condition after 3 second b If amending wagon No press digital key six digit input new wagon No then press lt function gt lt 4 gt key 7 Print Press lt function gt lt 5 gt the number of 2 or 4 shown Select print number you want 8 Division Optional grade for selection 1 2 5 10 press lt function gt lt 8 gt at a time the division convert next division Display and affirm after 3 second The converted order is 1 gt 2 5 10 1 9 Save a After hang the object from the ground till it is motionless in the air then press lt Save gt key the measuring value is auto saved in instrument The maximal saved times is nine When the maximal times gt 9 it is automatically print when connect printer And after eliminate saved measure value carry on saving tenth measure value b Press lt function gt lt print gt display saved measure value The scale will be back to work condition after 3 second 10 Date a Press lt function gt lt date gt the current date shown If it is right press lt input gt The scale will be back to work condition b If amending date press lt function gt lt date gt then press digital key six digit input new date then press lt input gt key The instrument will be back to work condition 11 Clock a Press lt function gt lt clock gt the current clock shown If it is right press lt inp
2. storage battery Daily maintenance must be needed Before starting check up antenna of connect avert charging antenna s B Ningbo BENUI electric Co Ltd r Add No 8 Laoshan Road Dagang Industry Zone It should be warmed up 3 5 minutes after starting It should be avoided to be overweight in a long term It can do great harm to the load cell No strike and librates scale body in using Recharge the battery after every using If it is not used in a long time recharge it once a month If the scale is not needed hang it or put it on a small vehicle Do not let the hook touch any object The storage environment should be dry and clear When the instrument is not use the switch of power supper is taking down and the power supper switch is well grounded Check small parts of the scale on time to ensure it in a good condition benui electric Ningbo City China Tel 86 574 8680 6868 86 574 8680 6866 Fax 86 574 8680 6862 E mail sales benui com Http www benui com www loadcell cn Modifications reserved All detais describe our products in general from only They are not to be understood as express warranty and do not constitute liability whatsoever
3. OCS XS series crane scale user manual Suggestion In order to keep your scale good condition please do read the direction book carefully and place it on hand for reference Catalogue Summarizing Special features Primary technical characters Basic operation and the function of keyboard Install export interface and connecting Guide of special display symbol Dimensions and weight Simple problems and solutions Guide of setting parameters 10 Maintenance and notice OOANDURWNE 1 Summarizing OCS XS electronic crane scale is Wireless Transmission measuring unit that combines weighing instrument of XK 3168S scale load cell and power supply together It can be directly hung on the hook of a hoist and ensure the scale to complete the tasks of loading and weighing goods synchronously The scale body is made of high strength aluminum alloy XS1 or armor plate structure XS2 Its structure is compact and safe measuring data and condition is wireless transmission the instrument has the function of taring zero save wagon No totalize weight clearing division selection setting and display clock and date save data at disconnection printing and extended scoreboard export etc the system is steady and operation is quite easy This type of scale can be widely used in manufacturing chemical engineering steel or fabric producing etc It is really a satisfying scale for modern management and high production efficie
4. and debug before leave factory Beside periodic verification the scale is not install and adjusts The user is not optionally hard up load cell etc firmware commonly 2 The one side scale body is install circuit board and sends board The other side is install 12V 7Ah airtight rechargeable battery The user is not optionally hard up screw etc firmware commonly 3 The sends antenna is fix up antenna socket of scale body crust 4 When the electrical source switch of scale moved OFF position peacetime the scale is turn off The electrical source switch of scale moved OFF position at working and the indication lamp is will be on 5 The power supper of instrument is use 220V and the power supper switch is well grounded 6 Connection of printer socket and scoreboard display CL EN DI GND 1000000000000013 1000005 1400000000000025 600009 Parallel print export socket scoreboard export socket 1 STRB 2 9 DO D7 11 BUSY 10 12 17 NULL 18 25 GND 6 Guide of special display symbol and indicating lamp After starting if zero position of empty is high HHHHHH HHHHHH shown LLLLLL After starting if zero position of empty is low LLLLLL shown If the signal is not incept in 5 second shown If h ight is high th tti l level Continue SN anged well is hig an setting alarm exe the sound will be on The transmission is sound exceptional Display winkl
5. e The voltage of scale battery is low 7 Dimensions and Weight drawing A drawing B 1 XS1 lt drawing A gt 3 2 2 XS2 lt drawing B gt Capacity Dimension mm 3 2 8 Simple problems and solutions Phenomena J udgment antenna No incept signal Low battery voltage Broken charger Battery cannot be charged supply of charger Indicating lamp for recharging Supply of charger is not working No power in socket Capacity Dimension mm 15 1010 260 320 260 120 200 80 20 1010 260 320 260 120 200 80 30 1280 260 320 260 150 250 70 ae A 10 810 340 260 190 100 180 55 15 1010 380 260 230 120 200 60 20 1010 380 260 230 120 200 60 30 1280 400 260 230 150 250 70 Checking the power hecki th Checking e power Recolusaing Weight Solutions No contact or shatter Check up scale and antenna of instrument Turing off the scale and recharging Check up charger above 12 00V normally Replacing battery Checking the power supply Turn off the scale and recharged The battery is continually recharged over 8 hours No voltage battery Unsteady display value Motion of weighting Waiting till the object is object motionless Insufficient warming time Warming up 3 5min Display of empty scale not equal to 0 Putting scale on ground Improving the style of for excessive time storage Right fix rinter and Cable break off g p No working of printer instrument connect cable Pr
6. le and then indicating lamp is light b The screen will show 99999 00000 gt 0 in turn now it is ready for measuring If the data is incepting normally the indicating lamp is aglimmer C If the screen shows the signal is not incept It is check up whether the power supper is turn on and antenna is tight 2 Zero If scale shows the number is not 0 please press lt zero gt key 3 Taring a When the gross is unknown hang the weight press lt tare gt the indicating lamp of net is light Then every time you can get the net weight of the object b When the gross is known input the value of gross press lt tare gt the indicating lamp of net is light Then every time you can get the net weight of the object Warning The instrument can store the value of accessories weight so every time you can get the net weight of the object till you changed the accessories or turn off the machine 4 Clear Press lt clear gt cLEAr shown and then press lt 0 gt lt input gt totalize and time of measuring is eliminated 5 Goods No a Press lt function gt lt 3 gt the goods No XXXXXX shown The scale will be back to work condition after 3 second b If amending goods No press digital key six digit input new goods No then press lt function gt lt 3 gt key 6 Wagon No a Press lt function gt lt 4 gt the wagon No
7. ncy This type of scale can meet the standard of OIML R76 due to it superior quality 2 Special features a Set all parameters by keyboard b Software calibrating Cc Internal clocks and calendar d Save data at disconnection e RS232 communication interface print interface f Scoreboard export interface 3 Primary technical characters 1 Basic parameters DIVISION Maximum LOAD MINIMUM LOAD k kg Kg OCS XS 1 1000 10 0 5 OCS XS 2 2000 20 OCS XS 3 3000 20 OCS XS 5 5000 40 NUMBER OF Type DEVISION Ni Pil PR OCS XS 10 10000 100 5 OCS XS 15 15000 100 5 OCS XS 20 20000 200 10 OCS XS 30 30000 200 10 2 Technical Characters Accuracy classes OIML II Zero setting range A F S Taring range 100 F S Result steady display lt 10 seconds Max safe load 120 F S Over weight range 110 FS alarm Limit coefficient 4 Power supply 12V 7Ah air tight rechargeable battery Working time gt 50 hours Instrument r f z ume powe 0 lt 15VA using up msrument g eledrieal ey onzo within aa AR battery source Instrument display Red digital tube height 25 4mm 6 bit Working temperature 5 0440 range Relative humidity range lt 90RH at 20 C Radio frequency 230MHz 450MHz increment five dot Distance of wireless er gt 100m transmission 4 Basic operations and the function of keyboard 1 Starting a Turn on the power switch on the rear panel of the sca
8. oblems of printer Repair the printer 9 Guide of setting parameters Guide of setting method Press lt function gt lt calibration gt key shown Input number 96618 press lt input gt shown Affirm whether the scale is null If the scale is empty press lt zero gt then press lt input gt LOAD shown Loading calibrated weights press lt input gt the old calibration value XXXXXX shown Input the weight value of loading weights by number key then press lt input gt key and the old over weight XXXXXX shown Input new over weight value by number key then press lt input gt loading weights value shown The calibration is end Setting parameters Press lt function gt lt calibration gt key shown Input number 86138 press lt input gt the current calibration value shown Press lt input gt key the decimal digits P X shown then amend decimal digits 0 5 by corresponding digits key Press input key the 0 4d ISN at one division d X shown It is auto setting in calibration Press lt input gt key the over weight value XXXXXX shown and then amend over weight value by corresponding digits key Press lt input gt and then finish the setting parameter 10 Maintenance Electronic crane scale is an exquisite measuring unit Its power comes from
9. ut gt The scale will be back to work condition b If amending clock press lt function gt lt clock gt then press digital key six digit input new clock and then press lt input gt key The instrument will be back to work condition 12 Tantalize When the saved times lt 9 press lt total gt print saved measure value After print end the saved measure value is eliminated 13 Gross Net Press lt Gross Net gt it is convert between Gross and Net If the indication lamp of Gross is light the scale will be in Gross condition if the indication lamp of Net is light the scale will be in Net condition 14 Turning off and recharging After using put off the power switch on the rear side of the scale in prevent of damaging to battery and recharge it in time XS1 Turn off the switch on the under side of the scale insert charger s plug into the socket of 220V Then connect the charger and the scale with a lead The indicating lamp on the rear side of the panel will be on The scale now is in the course of recharging XS2 Turn off the switch on the rear side of the scale insert charger s plug into the socket of 220V Then connect the charger and the scale with a lead The indicating lamp on the rear side of the panel will be on The scale now is in the course of recharging Warning the battery is continually recharged over 8 hours 5 Install export interface and connecting 1 The scale body is install