Home
HOBO Weather Station User`s Guide
Contents
1. Section 3 Field Setup Tasks for Setting up the Tri pod e Task 1 Assemble Tripod page 24 e Task 2 Install Grounding Kit page 31 e Task 3 Temporarily Install Upper Mast Optional page 32 e Task 4 Mount Cross Arm Optional page 33 e Task 5 Mount Upper Mast to Lower Mast page 34 e Task 6 Mount Logger to Upper Mast page 35 e Task 7 Install Guy Wire Kit Optional page 36 e Task 8 Position and Level Sensors page 38 e Task 9 Final Setup page 38 HOBO Weather Station User s Guide 23 Section 3 Field Setup Task 1 Assemble Tripod There are two types of tripods available the 2 meter Part M TPB and 3 meter Part M TPA The 2 meter instructions begin on this page The 3 meter instructions begin on page 27 2 meter tripod lower mast assembly instructions This is an example of a typical 2 meter tripod assembly with a Rain Gauge sensor mounted on separate 1 5 meter mast the Rain Gauge should be further from the tripod in the field than shown in this example Wind speed sensor PAR sensor Upper mast Solar radiation shield Logger Rain gauge Tripod 1 5 meter mast Lower Mast Rain gauge cable Figure 4 2 Meter Tri pod 24 HOBO Weather Station User s Guide Section 3 Field Setup 1 Open the 2 meter tripod and place it in an upright position 2 Using a 1 2 inch wrench build six nut and bolt assemblies 5 16 18 like the one shown below QAQA ga m Figure 5
2. Sensor Activity There is activity on the sensor Network activity is defined as communication network from the logger to the sensor or vice versa Delay Start Button Start Error The logger has been configured to launch with a delayed start will continue blinking until the defined start date time The logger has been configured to start with a button start will continue blinking until you press and hold the button on the logger for a couple of seconds Every two seconds while the logger is recording data from sensors The battery power is less than 25 capacity Less than 25 of memory is available for saving data There is or has been a sensor communication failure The logger will not record measurements while this light is blinking Sensors can be added at this time The logger will not record measurements while this light is blinking Sensors can be added at this time Sensors cannot be added at this time The logger will continue to run However you should read out the logger and then replace the batteries soon The logger will continue to run until all memory is used This light will only blink if the launch parameter Wrap Around When Full is not selected see the Launching section on page 11 for details on the Wrap Around When Full setting If this light is blinking in conjunction with the OK light there was a communication failure The system has recovered but you may have an inter
3. Nut and bolt assembly 3 Take one of the nut and bolt assemblies and insert it through a tri clamp hole with the bolt head facing outward 4 Loosely install a nut on the bolt to the inside of the tri clamp Figure 6 Tri clamp and bolts 5 Install the remaining five nut and bolt assemblies in the same manner for both upper and lower tri clamps Make sure the bolt assemblies on the upper and lower mast tri clamps leave enough room for the lower mast section to slip through 6 Slide the lower mast from the top into the tri clamps with the creased end of the mast facing up The creases on the lower mast should face north and south HOBO Weather Station User s Guide 25 Section 3 Field Setup 7 Tighten the tri clamp bolts by hand so that the mast is temporarily locked into position Note The lower mast can rest on the ground at this time You will adjust the height of the lower mast later Lower mast 2 Meter tripod Tri clamps Figure 7 2 meter tripod lower mast 8 Because the tripod for the 2 meter configuration has non adjustable legs you must verify that the mounting surface area is level If it is not use shims or remove soil as needed You can attach the Post Level Part M MLA to the mast to verify that it is vertical as you level the surface You can also use the tri clamp bolts to fine tune the vertical adjustment later after you adjust the height of the mast 9 Secure the tripod Use either the 14
4. 350 4 G 300 e 1 minute ZS e 5 minutes 2 250 J 10 minutes 15 minutes 5 200 J 20 minutes 30 minutes 150 100 5 50 4 0 T T T T T r T T T 0 20 40 60 80 100 120 140 160 180 200 Total Number of Bits Figure 1 Memory run time 46 HOBO Weather Station User s Guide Section 5 Reference Time Accuracy When you launch a logger its clock is set by the host computer s time and time zone offset from UTC UTC or Coordinated Universal Time is similar to Greenwich Mean Time The time zone offset makes it possible to determine objective non local time This prevents conflicts and confusion when you relaunch a logger with a shuttle that may have been launched in a different time zone or before a Spring or Fall time change Once the logger is logging it will keep fairly accurate time However the following may cause errors with time reporting e Host clock error The most likely source of error is an incorrect time or time zone setting on the computer that launched the logger Make sure the clock on your computer is set to the correct date and time before launching the logger One accurate resource is http www nist time gov e Launch time loss The logger may lose up to two seconds when it is launched This is a one time error that occurs as part of the start up sequence and cannot be avoided e Clock drift The long term time accuracy is a function of temperature The worst case error is 8 par
5. E WARNING Fire Explosion and Severe Burn Hazard The logger may contain a lithium battery The battery may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery case Do not attempt to recharge or heat the logger or battery above 185 F 85 C Do not dispose of the logger or battery in fire Do not expose the contents of the battery to water Dispose of the battery according to local regulations for lithium batteries WARNING Do not use weather station as part of a critical control system This system is not A intended to be a fail safe mechanism for anticipating life threatening conditions such as flash floods 2009 Onset Computer Corporation all rights reserved Printed in USA Onset and HOBO are registered trademarks of the Onset Computer Corporation Other products and brand names may be trademarks or registered trademarks of their respective owners HOBO Weather Station User s Guide Table of Contents Section 1 TO tr O d GE O T z32 1231125412551 5k y2n ka VEZO RA LA VE WE EWA EZO SWE VERE VAN V HORE LA W SE SA RA 5 HOW l Usethis Manual ss EE E 5 Specifications THT 6 Beleeg GO DOSTI Ay oea n ies ated R K ha Haan KERA a xuda weke R A thi neta Chaa a liraz 7 fo ra EW te LEE 8 Section 2 Set pand T SL ys kral kok aA a kesk ke 2 kurane hen ee D RA Wek NED 9 Items REQUIFGd T 9 elle Oe cies er ene HM ene HK MO
6. HOBO Weather Station User s Guide Section 3 Field Setup Section 3 Field Setup After you ve configured the logger and gathered the necessary materials for the field you are ready to assemble the tripod with the logger and sensors This document includes v Guidelines for typical field setup v Field preparation checklist v Tasks for setting up the Tri pod HOBO Weather Station User s Guide 17 Section 3 Field Setup Guidelines for Typical Field Setup Site Selection Use the following guidelines to help you choose an appropriate site for setting up the Station and protecting against field hazards A When possible select a location away from trees and buildings particularly if you will be using the rain gauge or wind speed sensors Place the rain bucket at a distance away from obstructions that is equal to at least three times the height of the nearest tree building or other obstruction and the wind speed sensor at a distance away from obstructions that is equal to at least five times the height of the obstruction WARNING Severe shock hazard Do not set up the HOBO Station near power lines Contact between the HOBO Station and power lines may result in a fatal shock electrocution or death Avoid placing the logger in extremely hot locations such as on a dashboard or the roof of a greenhouse and chronically wet locations such as in a well or any place that is wet most or all of the time Also avoid ris
7. details 10 Check the data and make sure it appears normal for all sensors Congratulations You have now launched and offloaded the Weather Station Proceed to Section 3 Field Setup on page 17 for details on deploying the logger 10 HOBO Weather Station User s Guide Section 2 Setup and Test Communicating with the Logger The logger has both an internal and external communication port for connection with a computer or U Shuttle See the Shuttle manual for information on using the logger with a U Shuttle The internal port is located inside the logger enclosure labeled comm port The external port is located outside the logger enclosure see Figure 2 and requires the weatherproof external communications cable Part CABLE HWS2 Use this port to quickly connect to the logger without having to open the logger door Launching the Logger There are several parameters you can enter when launching the Weather Station with the logger software To launch the logger connect to it as described in Communicating with the logger on page 11 and then enter the following launch parameters Note If you are launching the logger with a U Shuttle it will be launched with the parameters you last entered in the logger software on the computer Description Enter a description of the launch Battery type Make sure the appropriate battery type is selected otherwise the battery gauge will not be accurate when checking the logger s
8. ee eege ee 10 Communicating with the Logoger kk kk kk kk ek kek kk ka kk KA kk KA KA KARA KARA KAKA KAK KA KA KA 11 batine le he e Le TEE 11 Reading Out DD S Wvwe ggg b ooa 2g2p 12 aS T 13 Estimating Battery Lite i xun di lk si alal kl ika ka ka ARE H dak ke a pu al B kak hek kin A d k ke a ki kh kad Da b kelan 14 Lee ugeriet 14 Sania SO TOTA sya cay k Ki ea EaR J we Kaa Kak en OMA EE Ka E NAK KEWA RE KERA TN 15 Using a 9 Volt Battery EliminatlOr A 15 Adding and Removing Gensors sese eee eee 16 Section 3 PICIG S t WE 17 Guidelines for Typical Field Setup sse sees eee eee eee 18 Site SOleCllON EE 18 MOUIN ee n an SE a emer er eer aE xa RA ka Ke E KERA Ta kU ye AA a dese R ARA Kak 19 le Mie EE 19 Field Preparation Checklist kola A il nl bet dis b ni al ene gue bad Kurk n k eanne aw ze yed Kuna D n W NEEN 20 Tasks for Setting up the Trt p0od kk keka kk ka kr ka kr Ka kk K k A KA kr KA A KA kK KA KA KA 23 Task R Te Tea reet eeen bk ke a ek kaye be kk KE se C kre Dag ek AE Sed b ke b y ke kar xel bk RI ee S E katey ka 24 Task 2 lhstalli Grounding TEE 31 Task 3 Temporarily Install Upper Mast Optional 32 Task 4 Mount Cross Am Optional 33 Task 5 Mount Upper Mast to Lower Mast 34 Task 6 Mount Logger to Upper Mast 35 Task 7 Install Guy Wire Kit Optional 36 Task 8 Position and Level Gensors i yid sil sal n milla nue dk
9. has been recovered If your logger is damaged contact Onset Computer because there is a chance the data can be recovered The logger contains 512K bytes of memory Up to 10K of this memory is used to store the launch configuration and user notes leaving at least 502K bytes for data storage The logger software automatically estimates how long the logger will record data until the memory is full the run time based on the logging interval and the number and type of sensors connected In general adding sensors decreases running time while increasing the logging interval increases running time In most applications battery life limits the duration of the data logging before memory capacity The following figure shows the expected run time for several logging intervals based on the total number of bits in place which is determined by adding together the bits per sample for each sensor measurement parameter in your system For example a logger with the following sensors is using 70 total bits 4 Temperature xX B 82 1 Wind Speed X 16 16 1 PAR x 10 10 1 Rain Gauge x 12 12 Total number of bits 70 HOBO Weather Station User s Guide 45 Section 5 Reference At a logging interval of 5 minutes the memory run time for a Weather Station using 70 bits would be approximately 200 days based on Figure 5 See the sensor s manual for the number of bits each type of sensor uses 500 450 4 400
10. have become corrupted In rare circumstances the opened data file may have errors Offload the logger again and try opening the file again If that does not work contact your Onset dealer or Onset Computer Corporation Logger is not found e Check and replace the batteries e Check communications cable connections 50 HOBO Weather Station User s Guide Section 6 Troubleshooting HOBO Weather Station User s Guide 51 Onset Computer Corporation 470 MacArthur Blvd Bourne MA 02532 52 HOBO Weather Station User s Guide
11. inch diameter stake kit Part M SKB or bolt the tripod to cement pads with 4 inch anchors Install a stake or bolt through one of the holes on each of three tripod feet 10 If site conditions high winds etc warrant further stabilization of the tripod use the Guy Wire Kit Part M GWA See Task 7 Install Guy Wire Kit on page 36 26 HOBO Weather Station User s Guide Section 3 Field Setup 3 meter tripod lower mast assembly instructions This is an example of a typical 3 meter tripod assembly with a mast mounted Rain Gauge sensor Wind speed sensor P d PAR sensor CE Rain gauge E mast Solar radiation shield E 4 Logger Guy wire gt 4 Lower tripod Anchorplates Figure 8 3 meter tri pod HOBO Weather Station User s Guide 27 Section 3 Field Setup Using 5 16 inch nuts attach the three anchor plates to the three tripod foot brackets with the large 1 holes to the outside Tighten the nuts securely 2 Attach the three leg U bolts with saddle clamps one each onto the outer legs about 20 cm 8 inches up from the anchor plates P 1 P Q A U bolts with saddle Ab clamps n a Ji A Ve gt i a AA a d ech u L E ES oo o H Anchor Nuts D gt 9 plates Figure 9 3 meter lower tripod 3 Open the tripod and place it in an upright position 4 Unfold the leg brace assembly and place the assembly flat on
12. is not pre configured up to 15 sensor parameters of any type or combination can be added simply by plugging them in before logging begins e Digital network The connections between the smart sensors and the logger are digital ensuring accurate reliable data collection and storage How to Use this Manual This manual walks you through the steps of setting up operating and maintaining the HOBO Weather Station Use this manual to learn how to e Setup the logger and perform an initial test e Deploy the Weather Station in the field e Troubleshoot problems e Maintain the Weather Station It is important that you setup and test your logger using the steps in Section 2 before continuing with deploying the Weather Station on site For your convenience this manual includes three section dividers to organize sensor manuals and hardware packing lists It is recommended that you add all sensor manuals and hardware packing lists to this binder HOBO Weather Station User s Guide 5 Section 2 Setup and Test Specifications HOBO Weather Station Operating Range 20 to 50 C 4 to 122 F with alkaline batteries 40 to 70 C 40 to 158 F with lithium batteries Sensor Inputs 10 expandable to 15 with optional adapters Data Channels Maximum of 15 Some sensors use more than one data channel see sensor manual for details Communication 3 5 mm serial port or weatherproof external
13. of up to 30 characters to help identify individual sensors Deployment notes Add up to 2000 characters of notes about the launch Reading out Data You can read out data offload the logger with logger software Connect to the logger as described in Communicating with the logger on page 11 and then read it out If the logger is logging you can choose to either stop the logger before reading out or let it continue logging while reading out Readout speed depends on the method used to connect to the logger and the device being used Typically a readout via PC interface cable with the computer will take about six minutes for full memory 512K of data 12 HOBO Weather Station User s Guide Section 2 Setup and Test Batteries The Weather Station requires four 1 5 V AA batteries The logger is shipped with four alkaline batteries but it is also compatible with lithium batteries For most applications alkaline batteries are the preferred solution because e They are relatively inexpensive e The battery gauge in the logger software will provide an accurate battery status e They have slightly more usable capacity than 1 5 Volt lithium batteries in temperate environments In cold applications below 0 C 32 F and hot applications above 40 C 104 F lithium batteries will generally outperform alkaline batteries Alkaline batteries will still work in temperatures ranging from 40 to 50 C 104 to 122 F and from 20
14. the loose end of the turnbuckle and the wire clamp Make sure the turnbuckle is extended as shown in the figures before feeding the cable through Install the hooks turnbuckles and cables onto the other two stakes or tripod legs Tighten the three guy wires evenly by turning the turnbuckles Attach a Post Level Part M MLA on the upper mast to maintain the mast at vertical ge SN The guy wires should be taut when the installation is complete HOBO Weather Station User s Guide 37 Section 3 Field Setup Task 8 Position and Level Sensors Once the upper mast is locked in place and secured position the sensors at the correct heights and check that the Rainfall sensor and PAR sensors are level See the sensor manuals for more details Task 9 Final Setup 1 2 3 Open the logger enclosure Pass all the sensor cable ends through the opening on the bottom of the logger enclosure Plug all the sensors with tabs facing up into the logger board located within the logger enclosure It does not matter which connector you plug each sensor into You can use a maximum of 15 channels and 100 meters 328 ft of smart sensor cable Note If you are installing more than ten sensors you will need to install an adaptor Part S ADAPT for each additional sensor The adaptors fit into any of the connectors on the logger board except the upper left connector and the connector second from the bottom on the right If you have a HOBO
15. uj di xa kiwa ka na ki enk da da xa kan c va ki 38 Task 92 Final Setup EE 38 HOBO Weather Station User s Guide iii Section 4 MaintenaN el EE 41 General Maintenance xa 3yba iyana k l ani ya N ND ed ak L ba ke ya na kl DENK Kh d ha rake ca ken ika Wo SE a Kn Mada balaye 41 Performing a visual inspection eee e e e e ee 41 BEE 42 Checking Battery Status deet Kes kin Gn thease h deli v k ea YE i kc dera va thee T 42 Changing Batteries desen fer tie i ken dlya edged tien T 42 Cleaning the Weather Station eee eee 43 Verifying Sensor ee T 43 Section 5 Refer G lt s ssyasa s erase k leya E ey ke z a aw nez k va kek seya naz a 45 Memo d kiss b reb rekir ase kay neke R si D ka A d rek ly e b ke ke EEE kene erect KE Vek A EV se N LE 45 Til ACCURACY EE 47 Resettingithe e DY gg ggg xop ggggogggagmmgmmg er rrJ oN_O 48 Section 6 Troubleshooting ER 49 iv HOBO Weather Station User s Guide Section 2 Setup and Test Section 1 Introduction The HOBO Weather Station is a data logger designed for multi channel climate monitoring The Weather Station represents the next generation of data logging because it uses a network of smart sensors for taking measurements Key features of the smart sensors include e Automatic detection No extensive programming wiring or calibrating is required to set up sensors e Easy expansion Because the logger
16. visual inspection of the Micro Station tower and logger enclosure Check that e Cables and wires are not damaged cracked cut split or broken e All the screws and bolts are tightly secured e The mast is still level if in use e The ground attachments are fastened to the tripod and logger if in use e There is no excess rust replace rusty parts as necessary HOBO Weather Station User s Guide 41 Section 4 Maintenance Batteries Checking Battery Status There are two ways to check the battery status of the logger Check the Bat Low light on the logger This light blinks when the battery has 25 or less capacity remaining Check the status with the logger software For alkaline batteries the status is displayed in the percentage of capacity remaining Lithium battery voltage is either listed as good which represents anywhere from 25 to 100 of capacity remaining or empty which represents 0 to 25 of capacity remaining Lithium batteries have a relatively flat discharge curve which means the voltage does not vary much with use until they fail Because of the uncertainty in capacity it is recommended that you start new launches with fresh lithium batteries that you know are at 100 rather than relying on old ones Changing Batteries It is always recommended that you read out the logger before replacing batteries If you replace the batteries while the logger is logging it will stop recording data The data w
17. HOBO Weather Station User s Guide Contact Information For support please contact the company that you bought the product from Onset Computer Corporation or an Onset Authorized Dealer Onset Computer Corporation 470 MacArthur Blvd Bourne MA 02532 Mailing Address P O Box 3450 Pocasset MA 02559 3450 Phone 1 800 LOGGERS 1 800 564 4377 or 508 759 9500 Fax 508 759 9100 Hours of Operation 8AM and 5PM Eastern Time E mail loggerhelp onsetcomp com Main Onset Web site www onsetcomp com FTP site ftp onsetcomp com If you purchased the products through an Onset Authorized Dealer you can also refer to www hobohelp com for support information Safety Information Read first obstructions WARNING Severe shock hazard Before installing weather station tripod or mounting poles ensure that there are no electrical power lines overhead Do not install the system during any atmospheric electrical activity Do not assemble or transport tripods mounting poles or other structures unless there is sufficient clearance from potential electrical sources or other Injury may result WARNING Do not climb on or around the weather station tripod The weather station and any of its associated hardware towers poles etc are not designed to support the weight of a person pipes under the weather station WARNING If using stakes to stabilize the tower ensure that there are no underground wires or E EE
18. Slide the upper mast onto the lower mast with the dimple going into the crease and oriented north if you are in the northern hemisphere and south if you are in the southern hemisphere 4 When the upper and lower masts are aligned install the 1 5 8 inch U bolt assembly onto the upper mast placing it just above the dimple about 2 5 cm or 1 inch from the upper mast bottom Tighten the clamp 4 Upper mast U ma A A ei Upper mast overlapping el T thelower mast Lower mast CH L_i Upper mast dimple facing north in northern hemisphere _Lower mast crease __ n Jee Lower mast sc X i A tri clamp Figure 16 Upper and lower mast assembly If you are using a Wind Speed sensor and have not attached the cross arm go to Task 4 Mount Cross Arm Optional on page 33 34 HOBO Weather Station User s Guide Section 3 Field Setup Task 6 Mount Logger to Upper Mast 1 Using the two 1 5 8 inch U bolt assemblies provided mount the logger enclosure on the lower end of the upper mast in line with the upper mast dimple The lower housing U bolt can be placed directly above the U bolt holding the mast pieces together Note When assembling the U bolts place the U bolts around the upper mast and install the saddle clamp Place the logger enclosure against the saddle clamps and screw on the top U bolt nuts only Mast dimple Figure 17 Logger Housing on Mast 2 Ifyou are using the Guy Wire kit pos
19. U Shuttle or laptop on site check current sensor readings to ensure the sensors are all working For the HOBO Weather Station note that you cannot check current readings if the logger is waiting for a Button Start or a Delayed Start Neatly wrap all the sensor cables together and secure to the mast or tripod legs using cable ties Gather the excess cable and attach the cable ties to the upper mast behind the logger Leave about a 2 inch 5 cm drip loop of cable below the logger Sensor cables lt Drip loop Figure 21 Sensor Cables on Mast 38 HOBO Weather Station User s Guide Section 3 Field Setup 7 Seal logger enclosure HOBO Weather Station Only This step is especially important if the system is located in a wet environment Once you verify that the cables are secured in the inside of the logger box take all the cables and push them over to one side of the logger enclosure opening Using the duct seal make a ball that is bigger than the logger enclosure opening stuff the duct seal into the hole from the outside filling the void between the cables and the housing This minimizes the possibility of dust insects and driving rain getting into the logger housing Flare out the duct seal on the inside to lock it place All cables should be neatly secured to the mast when complete NOTE If you are using a HOBO Weather Station in a wet environment place several dry desiccant packs inside the log
20. am explains the key parts of the Weather Station Start logging button use this button when the logger is configured to launch with button start Press and hold a until all lights flash computer or U Shuttle allowing you to keep the logger closed while reading out launching or checking status adapter Part S ADAPT to plug up to 15 sensors in these ports NO G LO zz t7 NS Status lights see the table in this section for Internal communications details on each of the port used for connecting to seven lights _ e e O the computer or U Shuttle n Sensor connection E v d External communications port used for connecting to the Q e Battery door covers four AA batteries and auxiliary 9 Volt battery port ports where up to 10 smart sensors can be plugged in Use a sensor Cable tie bracket s BOn Battery door thumbscrews able tie bracket use to SS unscrew these to remove secure the sensor cables EA iN di gt battery door with a cable tie Figure 1 All logger components HOBO Weather Station User s Guide Section 2 Setup and Test Status Lights There are seven lights on the Weather Station that indicate logger activity and status The following table explains the function of these lights This light Blinks when
21. asurement averaging Check the sensor manual to see if your sensor supports measurement averaging e Make sure the Use Before date on the battery housing is at least two years from the current date e Alkaline batteries will lose up to 10 of capacity a year sitting on a hot shelf and can lose up to 50 or more if cooked repeatedly for example stored on a car dashboard Keeping batteries in the refrigerator can reduce self discharge to 1 to 2 per year however be sure to avoid condensation forming on the batteries e Use new batteries if you expect the deployment to require a substantial portion of battery life based on the table above e Batteries are relatively inexpensive don t take a chance with suspect batteries 14 HOBO Weather Station User s Guide Section 2 Setup and Test Using a 9 Volt Battery The Weather Station has an additional 9 volt battery connector adjacent to the four AA battery compartment Insert a 9 volt battery to temporarily maintain the power to the logger which allows you to replace aging AA batteries with fresh ones without interrupting logging Steps 1 Unscrew the two thumbscrews on the battery door cover and remove the battery door 2 Plug a9 Volt battery into the battery connector to the right of the four AA batteries observe polarity Press firmly to make sure the connection is solid Remove the old AA batteries Insert the new AA batteries Remove the 9 Vo
22. connector Dimensions 23 cm H x 10cm D x 18 cm W 9 x 4 x 7 inches Weight 0 9 kg 2 Ibs Memory 512K nonvolatile flash data storage Memory Modes Stop when full wrap around when full Operational Indicators Seven status lights provide logging and sensor network status Logging Interval 1 second to 18 hours user specified interval Battery Life 1 year typical use up to 10 sensors with 10 minutes or longer logging interval Battery Type Four standard AA alkaline batteries included for operating conditions 20 to 50 C 4 to 122 F optional AA lithium batteries available for operating conditions of 40 to 70 C 40 to 158 F Time Accuracy 0 to 2 seconds for the first data point and 5 seconds per week at 25 C 77 F Data Type Supports measurement averaging based on availability of supporting data from sensor Logger Start Modes Immediate push button or delayed start options Data Communication Current reading while logging offload while logging or offload when stopped Environmental Rating Weatherproof Mounting Mast 3 8 cm 1 5 inches maximum diameter or wall mount Enclosure Access Hinged door secured by four screws Sensor Network Cable Length 100 m 328 ft maximum Part Number H21 001 HOBO Weather Station User s Guide Section 2 Setup and Test Logger components The following diagr
23. e and bolting it to existing structures If you will be mounting PAR wind speed or rain gauge sensors be sure that you install the mast vertically using Mast Level Part M MLA Use the Guy Wire Kit Onset Part M GWA to stabilize a tall mast Use 1 2 inch stakes Part M SKA to secure the guy wires Mount the logger vertically and high enough that ground splash will not enter the vent on the underside of the enclosure If using U bolts make sure they are for 1 5 8 inch pipe because that is the hole spacing on the logger mounting bracket If mounting the logger to a post or wall note that it is 2 06 inches between the center of the holes in the mounting brackets It is recommended that you use 5 16 inch diameter bolts to mount the logger Installing Sensors If running cables along the ground we recommend running them through conduit to protect them from animals some animals like to chew on the cables lawn mowers and being tripped on For information on protecting the sensors properly refer to the sensor manuals Leave enough slack in the cables so that they can be routed into the logger If you are deploying multiples of the same sensor type be sure to note the serial number on the cable associated with each measurement location so you can interpret the data later HOBO Weather Station User s Guide 19 Section 3 Field Setup Field Use the Station Preparation Checklist following checklist to mak
24. e sure you have all the necessary materials for setting up a HOBO v Task Check that you received all the parts for the HOBO Station system as ordered Configure the logger Install batteries and set up the logger for launch If you opened any parts Double check the packing lists to make sure no pieces are missing Attach the mounting feet to the logger See the logger s manual If you are using the Solar Radiation Shield Set up the Temperature and Temperature RH sensors There are several small pieces required to connect these sensors to the shield that could easily get lost in the field It is strongly recommended you install these sensors in the solar radiation shield before going to the field See the sensor manual for details If you are using the barometric pressure sensor attach it to the logger now See the sensor manual for details Repack the logger and sensors for transit It is strongly recommended that you use the original packaging when possible because it is custom designed to protect the weather station and its components Gather the tools required for setup Use the following checklists to make sure you have the necessary tools to set up the logger in the field Optional Items depend on your site needs Logger Rain Gauge Sensor Item Item 1 2 inch wrench Mast level Part M MLA optional for mounting on separate mast Flathead screwdriver Sl
25. edgehammer or post driver optional for mounting on separate mast Desiccant optional Eye protection safety glasses if using sledgehammer post driver Light Sensor Slotted screwdriver Conduit optional Wind Speed Direction Sensor Item Item Ladder if deploying sensor above eye level Light sensor level Part M LLA 7 16 inch wrench Crescent wrench or second 7 16 inch wrench 20 HOBO Weather Station User s Guide Section 3 Field Setup v Task Soil Moisture Sensor Phillips head screwdriver 1 Compass T77 Gather the tools required for setup continued 1 06 inch 2 00 inch hose clamps if mast mounting without cross arm Phillips head screwdriver Temperature RH or Temp Sensor Hook and loop tape Item Y Item Trenching shovel spade or flat Phillips head screwdriver 1 if bar sensors are not already installed Water optional Conduit optional Barometric Pressure Sensor Pulse Input Adapter Item Y Item Hook and loop tape Two wire nuts 0 5 Volt Input Adapter 4 20 mA Input Adapter Item Y Item Hook and loop tape M TPB 3 m or 2 m Tripod with Mast M TPA or Cross Arm M CAA or M CAB Item v Item 1 2 inch wrench 1 2 inch wrench Mast level Part M MLA Crescent wr
26. ench Medium size wire cutters Crescent wrench Redimix cement optional Stake Kit M SKA or M SKB Shovel optional Item All purpose grease Sledgehammer Tape measure Eye protection safety glasses Tie wraps HOBO Weather Station User s Guide 21 Section 3 Field Setup v ITask 3 m Mast M MPA 1 5 m Mast M MPB Item 1 2 inch wrench Item Sledgehammer or post driver Sledgehammer or post driver Eye protection safety glasses Eye protection safety glasses if using sledgehammer post driver Mast level Part M MLA Mast level Part M MLA Redimix cement optional Redimix cement optional Shovel optional Shovel optional All purpose grease All purpose grease Tape measure Tape measure Grounding Kit M GKA Guy Wire Kit M GWA Item Item 1 2 inch wrench Phillips head screw driver 2 Sledgehammer 1 2 inch wrench Eye protection safety glasses Medium size wire cutters Medium size wire cutters Crescent wrench Solar Radiation Shield M RSA Light Sensor Bracket M LBB Item 1 2 inch wrench Item 1 2 inch wrench Phillips head screwdriver 1 if sensors aren t already installed 22 HOBO Weather Station User s Guide
27. ensor and check its wires and connector for damage and or signs of moisture In general it is recommended that you read out any data when this light is blinking investigate the problem and re launch the logger The battery low light is blinking after the batteries were replaced Check the polarity make sure the batteries are installed properly It is possible one cell is reversed Make sure you are using the correct battery type The logger uses four 1 5 volt AA alkaline or lithium batteries The type must be specified in the launch screen for the correct battery status Make sure you aren t using a combination of alkaline and lithium batteries Never mix battery types Check the battery expiration date make sure it is at least two years from the current date Batteries can lose significant capacity if HOBO Weather Station User s Guide 49 Section 6 Troubleshooting stored at elevated temperatures e Check the voltage with a voltmeter Alkaline batteries should be at least 1 5 volt per cell when new lithium batteries should be 1 6 volt per cell Batteries die e Check for excessive moisture in the logger enclosure Severe prematurely and or repeated condensation in the logger enclosure can lead to short circuits and battery failure It may be necessary to add additional sealing and or desiccant to the logger enclosure to prevent condensation e Check to make sure that both the logging and sam
28. ger enclosure remove desiccant pack from its foil pouch before installing 8 Recheck that all the U bolts nuts and clamps are secure for the entire system 9 If you are using a Weather Station launch the logger now The U 30 is automatically launched when powered up 10 Verify that the logger is operating properly Refer to the logger user manual for LED indications 11 Close the logger door For the HOBO Weather Station tighten the four cover screws Congratulations The HOBO Station setup is complete HOBO Weather Station User s Guide 39 Section 3 Field Setup 40 HOBO Weather Station User s Guide Section 4 Maintenance Section 4 Maintenance General Maintenance Regular maintenance on the Weather Station is essential because it extends the life of the components and helps to ensure the accuracy of recorded measurements When the logger is deployed in the field potential damage can come from numerous sources such as rodents birds vandals and heavy storms Periodic check ups in the field allow you to e Check that the station is still set up and functioning as you intended e Check for damage e Minimize the impact of any damage found This is particularly important if the logger is being deployed for a long period of time such as several months or a year Regular checkups will help ensure that you are continuing to gather data as expected Performing a visual inspection Periodically perform a
29. ill not be overwritten however until the next launch Follow these steps to change the batteries 1 Sn KON ece E d e If the logger is currently logging you will need to stop logging and readout the data If you do not want to stop the logger see the next section for instructions on how to use a 9 volt battery to temporarily continue power while changing the batteries Unscrew the two thumbscrews on the battery door cover and remove the battery door Remove the old AA batteries Insert the new AA batteries Replace the battery door cover and thumbscrews Launch the logger using the computer or U Shuttle Double check the battery gauge in the logger software to make sure the batteries you installed are full capacity Replace the battery door cover and thumbscrews 42 HOBO Weather Station User s Guide Section 4 Maintenance Cleaning the Weather Station The logger enclosure does not require regular cleaning However it is recommended that in dusty locations you regularly clean these items Solar radiation shield Wash with soap and water Dirt cobwebs obstruct air flow Discoloration can cause increased solar absorption which can result in increased errors Do not get the temperature RH sensor wet see the temperature RH sensor manual for instructions on cleaning it Light sensor Make sure the drain hole is not plugged If you need to clean the sensor head see the sensor manual for details and cautions on p
30. ing water and flood zones Conduit is recommended when placing a sensor in or near the ground to protect against animals lawn mowers tractors exposure to chemicals etc Beware of rodents birds cattle and other animals that can bite peck or trample the HOBO Station Avoid placing the sensors near falling rocks dead trees or other objects that could fall on the HOBO Station A Grounding Kit Part M GKA is required if using the wind speed or wind speed and direction sensor with the logger A Grounding Kit is recommended if the logger will be placed in an exposed location on a tripod or tower to reduce the chance of damage from atmospheric electrical activity If possible avoid sites immediately adjacent to radio television microwave towers and equipment In rare situations strong electromagnetic interference may result in sensor network errors Take note of the mounting considerations in the sensor manuals for additional guidelines relative to the particular sensors you are using For areas with winds greater than 50 mph or if the rain gauge is attached to the top of the mast use the Guy Wire Kit Part M GWA and 1 2 inch Stake Kit Part M SKA to reduce wind induced vibration 2 meter Tripod Tower Assembly Part M TPB You must set up the tower on level ground there should be no ground slope The legs on the 2 meter tower are non adjustable If the site you are using is not level then you will need to either level it
31. ition the logger enclosure so that it will not be in the way of guy wires 3 Attach the logger s ground wire to the lower housing U bolt Screw on the lower U bolt nuts and then tighten all the U bolt nuts HOBO Weather Station User s Guide 35 Section 3 Field Setup Task 7 Install Guy Wire Kit Optional NOTE If you are using the 2 meter tripod you will need to attach the guy wires to three 1 2 inch stakes Part M SKA which should be spaced evenly around the tripod at a distance of 3 to 4 m 10 to 13 ft from the mast 1 Ifyou haven t already done so attach the upper mast tri clamp to the upper mast Orient the eyebolts on the upper clamp so they align with each tripod foot or a 1 2 inch stake 2 Attach one end of the guy cable to one eyebolt on the upper mast tri clamp Open the wire clamp by loosening the screw on it Place the clamp over the wire and tighten Leave 2 5 cm 1 inch of wire protruding from the clamp Is E TT ang E l eee A tri clamp Wire clamp screw Upper mast gt 1 in 2 5m of exposed cable Figure 18 Guy wire attachment 3 Hook one S hook and one turnbuckle onto the corresponding stake or leg Turnbuckle S Hook Figure 19 Guying to 1 2 inch Stakes 36 HOBO Weather Station User s Guide Section 3 Field Setup Turnbuckle Figure 20 Guying to 3 Meter tripod feet 4 Cut the guy cable so that it can be put through
32. lt battery Replace the battery door cover and thumbscrews Sch Oy OU E ZS Verify that the logger is operating normally by checking that the Logging OK status light is still blinking every two seconds While it is possible to run the logger with only a 9 Volt battery it is not recommended for extended deployment for the following reasons e A9 Volt battery will only last about one to two months typical use e The logger and its software do not provide an accurate battery level indication for a 9 Volt battery e The logger battery door cannot be used with a 9 Volt battery in place it is possible that the batteries will shake loose e The 9 Volt battery cannot be used as a backup battery The opposite actually occurs the 9 Volt battery will be used first and then the AA batteries will be used Note When changing batteries on the fly the 9 Volt battery must have at least 7 5 volts remaining If the 9 Volt battery has less than 7 5 volts the battery gauge will not reset when new AA batteries are installed Use a fresh 9 Volt battery if you find that the battery gauge does not reset Using a 9 Volt Battery Eliminator In some applications where AC power is available it may be convenient to use a 9 Volt batter eliminator to power the logger 9 Volt DC supplies are commonly available from electronics supply stores Radio Shack catalog number 273 1552B Minimum DC current should be 9 mA If four AA batteries are also
33. mittent problem If this is the only blinking light then at least one sensor is currently not communicating Immediate investigation is recommended In general it is recommended that you read out any data when this light is blinking investigate the problem and re launch the logger HOBO Weather Station User s Guide Section 2 Setup and Test Section 2 Setup and Test Onset recommends that you setup and test the logger before deploying the Weather Station in the field Items Required To setup the logger you will need the following materials Flat head screwdriver Four AA alkaline batteries included with the logger or four AA lithium batteries One or more smart sensors PC interface cable Onset part number CABLE PC 3 5 Computer with logger software installed HOBO Weather Station User s Guide Section 2 Setup and Test Steps Complete the following steps to setup your Weather Station 1 Use a flat head screwdriver to loosen the four screws on the front cover of the logger Open the logger door Unscrew the two thumbscrews on the battery door cover and remove the battery door Insert four AA alkaline or lithium batteries observing polarity Once the batteries are installed correctly the status lights will blink for a second See Batteries on page 13 for more details Status lights ommunications port Fl FL FA FF Se _ ___ jan n Battery doo
34. ngth and discard or recycle Tighten the clamp bolt Groundrodciamp Groundrodclamp bolt Groundwire gt Groundrod Figure 13 Ground wire attachment HOBO Weather Station User s Guide 31 Section 3 Field Setup Task 3 Temporarily Install Upper Mast Optional This section explains how to temporarily attach the upper mast to the tripod base This allows you to easily work on the upper mast while it is resting on the base of the tripod Note If you prefer to permanently install the upper mast at this point because you will be able to reach the fully assembled tower go to Task 5 and then return to Task 4 Otherwise follow these temporary steps and then permanently attach the upper mast later 1 If you will be using the Guy Wire Kit Part M GWA install the guy wire upper mast clamp about two thirds up the upper mast Tighten the clamp by hand to temporarily hold it in place You will need to adjust it later Stand the upper mast upright and tie a cable tie to one leg brace and one leg of the tripod using the cable ties supplied Remove the cable ties after the cross arm and sensors are installed IETA N Postlevel z Figure 14 Upper mast temporary 32 HOBO Weather Station User s Guide Section 3 Field Setup Task 4 Mount Cross Arm Optional Onset recommends that you use the cross arm to mount the Wind Speed or Wind Speed Direction sensor because it keeps this
35. of the same type while logging If you would like to replace a sensor with another sensor of the same type for example swap a temperature sensor with a new temperature sensor it is necessary to read out the current data from the logger and re launch with the new sensor e A maximum of 15 data channels can be used with one logger Most sensors use one data channel which means the sensor is measuring one property only for example a temperature sensor uses one data channel that records information for temperature However there are some sensors that measure more than one property such as the combination temperature RH sensor which uses two data channels e To expand the number of sensors plugged in and data channels used use 1 to 2 sensor adapters Part S ADAPT which allow you to plug two sensors into one port Note that the 1 to 2 adapter is similar to a standard telephone splitter but it has 6 conductors Most telephone splitters have only 4 conductors A 4 conductor splitter may work but it is not recommended because the shield in the cable will not be properly grounded e The logger can work with a maximum of 100 meters 328 feet of smart sensor network cable which is the digital communications portion of the sensor cables If you are using multiple sensors be sure to check the length of each smart sensor network cable reported in the Sensor Manuals Add them together and make sure they do not exceed 100 meters 328 feet 16
36. or use shims to level the tripod Be prepared to dig if necessary Suggested Mounting Use 1 4 inch Stake Kit Part M SKB 3 meter Tripod Tower Assembly Part M TPA The maximum ground slope is 13 degrees The legs on the 3 meter tower allow for limited adjustment on uneven ground Be prepared to dig if necessary if the slope is significant Suggested Mounting Use 1 2 inch Stake Kit Part M SKA Onset recommends that two people set up most tripod systems Some assemblies are heavy and are easier to handle with two people Be sure to stabilize level and secure the tripod on firm ground It may be necessary to adapt the installation to the existing site conditions as necessary for example if mounting the tripod on ice or rock you may need to use a masonry clamp to secure it If operating in a wet environment place several desiccant packs in the logger and plug the vent hole in the bottom of the logger enclosure to minimize moisture 18 HOBO Weather Station User s Guide Section 3 Field Setup Mounting It is possible to mount the logger and sensors on either a 1 5 meter or 3 meter mast Part M MPB and M MPA respectively The shorter mast is especially useful for smaller system configurations where you are trying to minimize the size and visibility of the system There are many ways to install the mast depending on the site Common mounting methods include pounding the post into the ground setting it into concret
37. ow The logger will start recording measurements as soon as you are finished configuring the launch Delayed start The launch is postponed until the exact date and time you specify You can add sensors to the logger any time before the specified start time Button start The launch will not start until you press a button on HOBO Weather Station User s Guide 11 Section 2 Setup and Test the logger This allows you to configure the launch settings in advance but start the actual launch when you want without choosing a specific date and time You can add sensors any time before pressing the button on the logger Save settings for a later launch Select this option when you Want to save the current launch settings for a future launch but not start the launch now for example prior to heading into the field This is useful if you plan on launching the logger with a shuttle which doesn t allow you to change launch settings Wrap around when When this box is checked new data will overwrite the oldest data in the full logger sequentially one sample at a time when the memory is full The logger will continue logging indefinitely until either the logger is read out and stopped or the battery fails If this box is not checked the logger will stop logging when the memory is full and preserve acquired data For more information on memory see the Logger memory section on page 45 Edit sensor locations Give each sensor a name
38. pling intervals are set for at least 1 minute or greater Sampling Logging intervals faster than 1 minute will rapidly deplete the battery See the section on Estimating battery life on page 14 for more details e Check for damaged wiring and or sensors Damaged cables or connectors can result in complete or partial sort circuits that will rapidly drain batteries No status lights are e The lights are very faint In direct sunlight shield the sun and check flashing again e Make sure the batteries are not dead Batteries should have at least 1 volt per cell e The memory may be full Read out offload data from the logger and re launch e The logger may not have been launched Check the status with the logger software OK status light is not Make sure the logger is launched If you configured the logger to launch flashing with a delayed start check the date and time you selected and make sure the Delay Start light is flashing If you configured the logger to launch with a button start press and hold the button on the logger for a second until all the lights flash Data file contains errors If you are missing data for a particular sensor check that the sensor was properly installed Remove and re insert the sensor and check that it can take current readings If you find that it is not communicating it may be a bad sensor Contact your Onset dealer or Onset Computer Corporation Data file can t be The data file may
39. r Figure 2 Logger components thumbscrews Replace the battery door cover and thumbscrews Insert one or more sensors into the sensor ports Refer to www onsetcomp com for a current list of available sensors Onset recommends that you test all sensors you plan to deploy with the logger Refer to the manuals provided with the sensors for sensor specifications mounting information and recommended maintenance See Adding and Removing Sensors on page 16 for details Plug the PC interface cable into the internal communications port on the logger See Communicating with the Logger on page 11 for details Using the logger software click the Launch icon If the logger is not found make sure the correct COM port is selected Refer to the HOBOware User s Manual for details on changing the COM port See Launching the Logger on page 11 for details Make sure all the sensors connected to the logger are visible in the Launch screen Choose a Logging Interval of a few seconds so that your test will yield enough data to analyze Select the Start Logging Now option and click the Start button to launch the logger The logging ok light on the logger should blink every two seconds during logging After a couple of minutes click the Readout icon in the logger software to offload data from the logger You can choose to either stop the logger before reading it out or let it continue logging while reading out See Reading out Data on page 12 for
40. r in the launch screen Click the Reset or Add Sensor button in the launch screen Check for a loose connection between the sensor and the logger Make sure you havent exceeded the maximum of 15 sensors connected to the logger Note that some sensors are dual sensors and count as two such as the temperature RH sensor and the wind speed sensor If you have more than 15 sensors remove one or more until you have 15 or less Make sure you havent exceeded 100 meters 328 ft of network cable Remove all but one sensor then check if the sensor appears in the launch screen Continue to remove and re insert the sensors one at a time until you find the bad sensor If you find a bad sensor or if none of the sensors communicate contact your Onset dealer or Onset Computer Corporation The error status light is blinking If the error light is blinking in conjunction with the OK light there was a communication failure The system has recovered but you may have an intermittent problem Try checking the sensors one at a time to make sure they are all communicating If you find a bad sensor or if no sensor communicates contact your Onset dealer or Onset Computer Corporation If the error light is the only light blinking then at least one sensor is currently not communicating Immediate investigation is recommended Look for a loose connection which could cause bad electrical contact with a sensor If found remove the offending s
41. ries above 185 F 85 C Do not mutilate or rupture the battery housing Lithium batteries may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery case Do not expose the contents of the battery to water HOBO Weather Station User s Guide 13 Section 2 Setup and Test Estimating Battery Life Battery life will vary with e Logging and sampling intervals most important factor e The number of sensors connected e Battery type e Operating environment Use the following table to help you estimate how long the batteries will last the run time based on the logging interval selected and the number of sensors connected Note The run times in this table assume that the recommended battery type for the temperature range is being used Logging Sampling 1 to 5 sensors Interval Interval 1 second 30 to 50 days 1 minute 12 months 10 minutes 12 months 15 minutes 12 months Additional guidelines 5 to 10 sensors 10 to 15 sensors 20 to 40 days 9 to 12 months 15 to 30 days 7 to 10 months 9 to 12 months 9 to 12 months 12 months 12 months e Turn off the sampling interval unless you have sensors that support measurement averaging At the time of publication only the 12 bit Temperature Soil Moisture Barometric Pressure Photosynthetically Active Radiation and Solar Radiation smart sensors and the 4 20 mA and 0 5 Volt input adapters supported me
42. roper cleaning Rain gauge Make sure there are no leaves or debris in the collector Make sure the funnel is not plugged use a cotton swab if necessary to clean Anemometer on wind speed sensor Make sure the cups do not have any dirt dust cobwebs Spray bearing with a light oil Anemometer on wind speed and direction sensor Apply a couple drops of 3 in 1 oil or other motor oil to the bearings on the vein and anemometer Logger enclosure Remove dust with compressed air Do not get water inside the enclosure Tower Hose with fresh water if necessary Verifying Sensor Accuracy For most sensors Onset recommends that you test sensor measurement accuracies once a year Onset Computer can verify the accuracy of all sensors and recalibrate applicable sensors For more details on verifying sensor accuracy refer to the user manual included with the sensors HOBO Weather Station User s Guide 43 Section 4 Maintenance 44 HOBO Weather Station User s Guide Section 5 Reference Section 5 Reference Memory The logger uses non volatile memory which means it retains data indefinitely once power runs out Specifically the logger uses a high capacity Flash memory to store data which can retain the data even when the batteries are removed This type of memory is very durable If the logger dies in the field from dead batteries replace them and read out the logger immediately Do not relaunch the logger until the data
43. sensor away from other sensors that could cause wind turbulence or wind shadows It is also the best way to ensure the sensor is vertical Steps 1 Attach the cross arm to the upper mast using the two 1 4 20 x 2 3 4 inch hex head bolts Mount the cross arm on the side opposite the dimple at the bottom of the upper mast with the word TOP on the upper surface of the cross arm 2 Pass the two bolts with flat washers on them through the two holes on the cross arm and through the two holes at the top of the upper mast Install a nylock nut on each bolt Do not securely tighten the bolts yet 3 Install the mast plug into the upper mast top with the slot facing down and going over the two bolts Note After the mast plug is installed it should be flush with the top of the mast 4 Tighten the two nuts equally n Mast plug not Nuts inserted yet Half cross arm Upper mast Figure 15 Half cross arm setup is same for full cross arm For directions on mounting the Wind Speed sensor to the cross arm see the sensor manual HOBO Weather Station User s Guide 33 Section 3 Field Setup Task 5 Mount Upper Mast to Lower Mast NOTE Onset recommends that two people work together to attach the upper mast to the lower mast 1 Lightly grease the creased upper end of the lower mast 2 While holding the upper mast securely cut the cable ties that were temporarily holding the upper mast to the lower mast 3
44. tatus Logging interval Set how often the logger will record data for example every 30 minutes hour etc The minimum logging interval is 1 second and the maximum is 18 hours Keep in mind that the faster the logging interval the more quickly the batteries will be depleted See the Estimating Battery Life section on page 14 for more details Sampling interval For use with sensors that support software selectable measurement averaging The sampling interval sets how often sensors will take measurements between logging intervals Check the sensor s data sheet or manual to determine if your sensor supports measurement averaging When a sampling interval is used during launch all the sampled measurements for the sensor are averaged together and the average is then recorded as one data point at each logging interval The individual data points that comprise the average are not saved only the final averaged data point is saved Set the sampling interval to one of the predefined settings from 1 second to 4 minutes The sampling interval must be less than or equal to the logging interval Sampling rates shorter than 1 minute will reduce the logger s battery life Important If you do not have any sensors that support measurement averaging set the sampling interval to Off as there will be no benefit and it will reduce battery consumption When to start Choose one of the following start modes for the logger logging e Start logging n
45. the ground j j j Figure 10 3 meter tripod leg brace HOBO Weather Station User s Guide 28 Section 3 Field Setup 5 Attach each of the three inner legs to each of the leg U bolt assemblies 5 16 18 inch using the inner stud of the U bolt To attach each inner leg remove the nut from the inner stud slide the leg over the stud and then tighten the nut finger Inner leg Anchorplate Figure 11 Three meter tripod inner leg 6 Loosen the three lock nuts on the bolts on the upper and lower mast tri clamp assemblies Back the three bolts out of the upper and lower mast tri clamp assemblies so that the lower mast section can be slipped down through the upper mast tri clamps and into the lower mast tri clamp with the creased end of mast facing up When the lower mast section is installed hand tighten the upper and lower mast tri clamps Upper mast _ gt SA tri clamp 7 Postlevel LA A T LA 3rd tripodleg Lower mast T a V Lower mast U bolt tri clamp g L a Usch ker A Figure 12 Three meter tripod lower mast 7 Install a Post Level Part M MLA on the lower mast as shown in the previous figure HOBO Weather Station User s Guide 29 Section 3 Field Setup 8 When the tripod is oriented on the site secure one of the three tripod legs to its mounting location and tighten the U bolts on this leg 9 Adjust the second leg to level in one direction and secure
46. this leg 10 Use the third leg to adjust the mast close to level 11 When the mast is close to being level secure the third leg 12 Fine tune the mast level by sliding the U bolts slightly up or down Tighten all three leg tri clamps using a 1 2 inch wrench Again verify that the mast is level 13 After checking level and orientation tighten all upper and lower mast U bolts and lock nuts 14 Orient the lower mast creases so they face north and south 15 Tighten the tri clamp bolts so that the mast is locked into position Note the lower mast should be about 8 inches 20 cm above the ground at this time assuming that if you are using the wind sensor you want it to end up at 3 meters or almost 10 feet 30 HOBO Weather Station User s Guide Section 3 Field Setup Task 2 Install Grounding Kit This section explains how to install the grounding rod from the Grounding Kit Part M GKA and attach it to the lower mast of either the 2 meter and 3 meter tripods 1 Attach the ground wire to the lower mast of the tripod using the U bolt assembly delivered with the grounding kit Slide the ground rod clamp over the ground rod prior to driving it into the ground This allows you to work with the clamp before the top of the rod is damaged from impact Using a sledgehammer drive the ground rod into the ground as close as possible to the lower mast of the tripod Attach the ground wire to the ground rod Cut off excess cable le
47. to 0 C 4 to 32 F however they may not be the best choice At temperatures lower than 20 C 4 F and higher than 50 C 122 F alkaline batteries are unsuitable use lithium instead If the temperature is variable across the extremes use lithium batteries Use the following figure to help you choose the battery type based on the expected temperature range in your deployment 40 C 30 C 20 C 10C ge 10 C 20 C 30 C 40 C 50C 60C 70 C ZARA L SLAR LS KERDI TA 2 gt pore Alkaline 40 F 22 F 4 F 14 F 32 F 50 F SS 86 F 104 F 122 F 140 F 158 F ag Recommended in this YA Works in this temperature temperature range range but not best choice Figure 3 Recommended battery type based on temperature Note e The logger is not designed to run with rechargeable or Carbon Zinc Heavy Duty batteries e The use of types other than 1 5 Volt alkaline or lithium batteries may result in poor battery performance and erroneous battery state indication WARNING Fire Explosion and Severe Burn Hazard Do not mix battery types either by chemistry or age batteries may rupture or explode When replacing the batteries read and follow their disposal instructions dispose of lithium batteries A according to local regulations Do not dispose of batteries in fire Never attempt to recharge a lithium or alkaline battery Do not heat the batte
48. ts per million PPM a week at 25 C which is about 5 seconds per week The error increases as the temperature deviates from 25 C see the figure below If the temperature were a constant 20 C the logger time error could be as much as 35 ppm 21 seconds per week The following graph shows the worst case time error 60 Negative s Positive Seconds per week PPM error Temperature in C Figure 2 Worst case time error HOBO Weather Station User s Guide 47 Section 5 Reference Resetting the Clock Reading out the logger and relaunching it will reset the logger s clock This is useful when your logger has been running for a while and its clock needs to be reset Make sure the computer clock is set accurately before relaunching 1 2 3 4 Exit HOBOware Pro and correct the computer s clock Restart HOBOware Pro Read out the logger if you have not done so already Relaunch the logger 48 HOBO Weather Station User s Guide Section 6 Troubleshooting Section 6 Troubleshooting This section lists common problems you may encounter with the Weather Station and possible resolutions Individual sensors are not found or are missing in the logger software launch screen All sensors are missing in the logger software launch screen If a sensor is removed and then immediately re inserted it may not be auto detected and therefore will not appea
49. used with the 9V battery eliminator they will serve as back up batteries Note The batteries will NOT be charged and rechargeable batteries should not be used with the logger HOBO Weather Station User s Guide 15 Section 2 Setup and Test Adding and Removing Sensors Smart sensors plug into the logger and collect data about various weather parameters Before you bring the logger and sensors to the field it is important that you gather and test all the sensors Specifically you should e Plug in all the sensors you plan to use e Make sure they are communicating and e Make sure the readings are valid To add a sensor simply plug it into a sensor port on the logger Follow these guidelines when adding sensors e Never add or remove sensors while the logger is recording data Sensors should only be added while the logger is stopped when configuring the launch parameters with logger software or after configuration but before the start of logging in Delayed Start or Button Start modes for more information on these modes see the Launching section on page 11 e Any sensors added while the logger is recording data will be ignored Logging will continue normally for other sensors If a sensor is removed while logging the Sensor Error status light will blink when the next logging interval is reached The data for that sensor will then display as missing or erroneous in readouts e You cannot replace one sensor with a new sensor