User Manual: 12-bit Digitizers

image

Contents

1. eeeeeeeeeeeeueuuse 35 4 2 10 DGS mened Memory n cum eundo Mitte CI LLLI M ea and 35 4 2 11 Display Features Zoom and Persistence cccccccccccccccceceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeseseseeeeees 35 45 3opLmeMenuofbACQqItisLiVe uicta ste n testate t adeste ad ient Re 36 Lr S aiio RR UI E 36 4 5 Store Autostore and Conversion of Waveforms eeeseeeeeeeee eee e eene eene nene rh tenere nne nan 36 d Pa O21 0 CoN RCRD NER PNR iit uite i En od ste e MM ee oe 38 Ad External t0 MHz Reference and External Clock scductiacdccausaswsasubvawabersuctd enthwapnnsvnnewessubeepsbeubacwoss 38 5 Additional Waveform Information zoe eere tested etse rete boe es PUER EE tribe weeded 38 Ag DIPATENI RE m m T c 38 Z0 Command Line switelesodusnedt meanen vss a a aa ven o oed reso Urea beso bene feud eae 39 5 RUNNING THE GEOMAPPER APPLICATION e eee eee eee eese e eee eessssss sese esee esee eeeae 41 5 1 Who needs a Geographical Map of Modules isorosi iaai aa aiat 41 5 2 When should the GeoMapper Application be used eeeeeeeeeeeeeeseeeeeseeeeeeeernel 41 59 HowdtodzuinCGeoMdDDEE uos coss esito ele as eoe en eee 8 tl occa Is bene Snead 4 6 APPENDIX A U1056A AS BUS FOR COMPACTPCI PXI DIGITIZERS 44 7 APPENDIX B XA001 BATTERY BACKUP FOR COMPACTPCI DIGITIZERS 45 8 APPENDIX C U1092A HVB XA100 BNC INPUT OVERVOLTAGE PROTECT
2. 3 3 4 Timing A crystal controlled timebase is used to clock the ADC system of the digitizers The timebase accuracy is guaranteed to be better than 2 ppm The digitizers also include a built in Trigger Time Interpolator TTI that measures the time from the trigger point to the first sample point This information is essential for determining the relation between the trigger or other event of interest and the digitized samples of the signal The TTI resolution is 5 ps for a sampling interval of 2 5 ns SR 400 MS s As the SR decreases the TTI resolution is kept at 0 2 of the sampling interval However there is a jitter of up to 60 ps in the positioning of the data with respect to the trigger point 3 3 5 Timebase Range The timebase range defines the time period over which data is being acquired For example the DC440 has a standard acquisition memory of 64 Kpoints and maximum warranted sampling rate of 400 MS s Therefore at this sampling rate the digitizer can record a signal over a timebase range of up to 160 us approx 64 000 points 2 5 ns point The timebase range can be adjusted by varying the amount of acquisition memory or the sampling rate of the digitizer 3 3 6 Sparkle code rate The high end Acqiris 12 bit digitizers DC440 and DP310 contain an analog to digital conversion ADC system that can sample waveforms at rates up to 420 MS s This makes them ideally suited to frequency domain observations On the other han
3. The AS bus distributes both the clock and trigger signals along a plug in front panel bus between all the digitizers that participate in the system It allows any digitizer to act as the trigger source and any other digitizer to act as the clock source acquisition master enabling all the digitizers to be clocked at the same time Synchronizing the clock signals between the devices improves the accuracy of cross channel measurements and is essential for accurate time correlation between signals on different channels The AS bus is intended to connect modules of the same type i e of the same model number although some exceptions to this rule might be possible If modules with the same model number but different memory length options are connected only the shortest memory length can be used The AS bus connector is located on the front panel of each module Bridges are used to connect adjacent modules for synchronization which is then activated through software by defining a master module and the trigger source Up to 7 modules may be synchronized with the AS bus More detailed information and the commands required to set up the AS bus clock and trigger distribution are included in the Programmer s Guide and Reference manual User Manual Agilent Acqiris 12 bit Digitizers Page 25 of 48 3 8 Special Front Panel Inputs and Controls MMCX CLK IN 50 Q External Reference or External Clock Input MMCX I O A User configurable see below MMCX
4. 100 MS s 3000 Some of these products are now offered with additional Optional Memory as standard 3 3 1 High Resolution Sample Rate The high end Acqiris 12 bit digitizers DC440 and DP310 contain an analog to digital conversion ADC system that can sample waveforms in a real time sampling mode at rates from 420 MS s down to 100 S s 10 ms per point The sampling rate can be programmed and is adjustable with a very fine granularity as partially shown in the table below Sampling SR Rate resolution MS s kS s 200 420 500 100 200 250 50 100 125 Sampling SR Sampling SR Rate resolution Rate resolution MS s kS s MS s kS s 62 5 There are 1360 allowed values for each decade The same pattern continues as one goes to the right beyond the table above The last entry would be for SR 100 200 S s and a resolution of 250 mS s For the DC438 and DP308 the sampling rate resolution is given by Sampling SR Sampling SR Sampling SR Rate resolution Rate resolution Rate resolution MS s kS s MS s kS s MS s kS s 100 200 10000 10 20 1000 0100 song 25 50 2500 250 025 0 20 25 1250 125 0 2 0 25 12 5 There are 34 allowed values for each decade The same pattern continues as one goes to the right beyond the table above The last entry would be for SR 100 200 S s and a resolution of 10 S s User Manual Agilent Acqiris 12 bit Digitizers Page 21 of 48 For the DC436 and DP306 the samp
5. J teriab CAlbEAHOD soos son it ae uasa s oU udo spp asse D e eoe 29 MEME or E 23 3 8 Special Front Panel Inputs and Controls eese nnns 26 30 cbwemnal Tee 0 A uoc E da tree crus ier ahs cee 26 3 10 Electrical Environmental and Physical Specifications eeeeeeeseeeseeeeeeeeel 2 3 10 1 EIGCIHC dl eet eee tto EA edet ca tite ee eer 27 3 10 2 Enviaromnental and Physical ette eate deste eapite 2 4 RUNNING THE ACQIRISLIVE APPLICATION e ecce eee eee eee eee eee eee etnn saos eoe e eee esee e tas 29 Al Getting Started with AcqirisLiaye sioe ertet dvi etant eot bas rho e noo sansdeds tolodins eoa bnd Pv ke SR R ae Eee ba Tv iode 29 42 Control Panel and Pufcllolsussoon sontes rei das s Pe Ete emanare veneered 30 4 2 1 Control Panel MI OGE NR TET 30 42 2 Displays Multiple TACOS ints otioso to mood eel on eaae baae a a oe netos 31 4 2 3 IN fBe Hc EGITOE m tits ebur iter mte dede bor A one tut te dudes c bovis Emus cele ctl ito 32 4 2 4 keybord SOM CUIS gt oosocite cutee ero bue edles bambou meto E O teme isst te 32 ALD Input Voltage Scale Offset and Coupling cc cccccccccccccccccccceceeeeeeeeeeeeeeeeeeeeeeseeeeeeseeeeees 33 4 2 6 AE ME ERREUR NIENTE RERO NIE eee 33 4 2 7 Acuto ModE T E 34 4 2 8 Pine base amd MEMO lt s20s 2s alas cum etat mitibus M Ei d I S MEE 34 4 2 9 Using digitizers of different models simultaneously
6. parameters used to configure each of the channels of each module together with the timebase and trigger configurations will be saved in a file You will be asked to choose the destination directory for the file and be allowed to give it an appropriate name When you choose to recover a file you will be asked to give the name or navigate to it using the browser functionality If you are using many modules the settings in the configuration file will be associated preferentially with the digitizer that has that serial number or then with the digitizer in the same location Only the parameters of the modules are stored in the configuration file This means that parameters of the AcqirisLive program such as channel activation and display mode choices are not included 4 5 Store Autostore and Conversion of Waveforms The store menu gives you two mechanisms to store waveforms 1 The Store Waveform option allows you to store the last acquired waveform for the current channel To store the last acquired waveform for each of the active channels you must sequentially select each one to make it the current channel and use the Store Waveform menu command The title of the Store Waveform dialog indicates the name of the channel that will be stored The data is stored in ASCII format as Raw ADC values or Amplitudes in Volts User Manual Agilent Acqiris 12 bit Digitizers Page 36 of 48 2 The Autostore option allows you to store consecutively acquired wa
7. CompactPCI crates can be left plugged in since this ensures proper grounding N CAUTION Touch the antistatic package to a grounded object before removing the card from the package Electrostatic discharge can damage the card 2 Module in a PC open the PC identify a free PCI slot and carefully insert the DP Series card into it Be sure to ground yourself by touching the grounded PC frame and avoid touching any components on the DP Series card Make sure that the grounding of the card s mounting bracket to the back panel rail of the computer is done correctly If present make sure that the fan s adjustable retainer is correctly positioned and tightened for mechanical support Close the PC Module in a CompactPCI crate Follow the instructions of the crate manufacturer to insert the DC Series card into a free 6U CompactPCI peripheral slot Be sure to ground yourself by touching the grounded crate and avoid touching any components on the DC Series card Be sure to tighten both front panel mounting screws to lock the module into place and insure proper grounding of the frame NOTE To ensure the best possible performance users of Acqiris CCI21 Crates with AS bus systems should respect the module placement rules to be found in the Agilent Acqiris 21 slot CompactPCI Crate User Manual PCI Bus extension module in a PC Consult the manufacturer s documentation for any special instructions Open the PC identify a free PCI slot and carefully insert t
8. Win98 2 2 Installing the Software under Windows 2 2 1 Warnings If Setup detects a previous installation of Acqiris software on your system a warning screen will be displayed It 1s recommended to exit Setup and uninstall older versions The installer from software releases prior to Acqiris Software 2 0 installed the Digitizer Driver DLL files into the System directory These will be removed by Setup If you wish to keep the old installation on your system you should exit Setup and move all Acgqiris driver files acqiris acqrs and acqir to some archive directory The DLL files will be installed into the bin subdirectory of the Acqiris software root and the corresponding path will be added to the PATH environment variable 2 2 2 Multiple Versions With the software installation from Acqiris Software 2 0 or above it is possible to keep multiple versions on the same system but you must specify a different root directory i e Install Folder If you keep the same directory Setup will overwrite your previous installation To go back to a previous version you must change the PATH environment variable and reinstall the Kernel driver Under Windows 2000 XP l Copy the SYS file from lt old_AcgirisSoftware_root gt bin kernel to the Windows System32 drivers directory 2 Change the AcqirisDxRoot AcqirisDxDir and PATH environment variables to the old root 3 Reboot the computer User Manual Agilent Acqiris 12 bit Digitize
9. card In the event of accidental damage or as components fatigue over time e g relays in high duty cycle automated testing applications the mezzanine card allows for fast and efficient replacement 3 2 4 Bandwidth and Rise Time The bandwidth specification indicates the frequency at which an input signal will be attenuated by 3 dB approximately 3096 loss of amplitude The bandwidth also affects the minimum rise and fall times that can be passed through the front end electronics A pulse with a very sharp edge will be observed to have a minimum rise time Tmin determined by the front end electronics In general a pulse with a given 10 90 rise time T10 90rea Will be observed with a slower value given by 2 2 2 Tio 90 Tio 90rea T Tmin The following table indicates the bandwidth and rise time performance of 12 bit digitizers Model Bandwidth Minimum BW Limiter Other particularities Agilent into 50 Q Rise Time selections DC440 35 MHz 2 pole 300 MHz Direct HF Input U1066A 001 Bessel DC438 35 MHz 2 pole U1066A 002 oe DP310 35 MHz 2 pole U1070A 001 nm DP308 35 MHz 2 pole U1070A 002 oe DP306 U1070A 003 User Manual Agilent Acqiris 12 bit Digitizers Page 19 of 48 3 2 5 Input Voltage and Offset The Standard Input provides a fully programmable amplifier with variable input voltage and offset Full Scale FS input voltages are selectable from 250 mV to 10 V in a 1 2 5 sequence Care should be taken to select an i
10. e Debian sarge 3 1 kernel 2 6 8 3 686 e Suse Linux 9 2 kernel 2 6 8 24 smp e Scientific Linux 4 4 kernel 2 6 9 42 0 10 EL 1686 e Debian etch 4 0 kernel 2 6 18 4 686 For other Linux distributions the loadable kernel module will have to be compiled from the sources 2 3 1 1 Using a compiled kernel module To install the device driver you have to rename the kernel module whose name matches the version of your kernel to a name without this version number You can find the running version of your Linux kernel by running the command uname r Then if there is a kernel module that matches yours you can rename the file cd AcqirisLinux lib modules OD acgrsPCL koln dodgrsPQOLb ko where n is the running version of the Linux kernel 2 3 1 1 Compiling the kernel module All files needed to compile a new kernel mode driver are in AcqirisLinux linuxdriverpci for Linux kernels 2 4 or AcqirisLinux linux2 6driverpci for Linux kernels 2 6 To compile the driver the header files of the Linux kernel need to be installed Furthermore depending on the Linux distribution the kernel source files may need to be installed too 2 3 1 1 1 Compiling for Linux kernels 2 6 The makefile will try to guess where the kernel headers are located If it fails see the instructions inside the makefile itself to specify manually where these kernel header files are located To compile a new kernel module use the following commands C
11. s Please note that switching DMA data transfer mode off precludes the use of acquisition interrupts The i switch will therefore be ignored when n is used User Manual Agilent Acqiris 12 bit Digitizers Page 39 of 48 Process Priority When the program checks for an event from the operating system e g to react to user input it can put itself to sleep for a specified period of time This gives other applications more processor time but limits the performance of AcqirisLive in terms of maximum acquisition rate The default is not to go to sleep but this can be overridden to allow better performance for other applications Note that this sleep policy is only in effect while the acquisition 1s running When the acquisition stops the sleep policy is always reset to the longest sleep period Acquisition Interrupts When performing acquisitions there are 2 possible ways to wait for the acquisition to complete polling or using a hardware interrupt e p Polling AcqirisLive runs as a single thread process After an acquisition is started the instruments are regularly polled to check when the acquisition is complete The user interface 1s still alive but the latency for reading the data after the acquisition may vary i Hardware interrupt In this mode AcqirisLive is run as a multi thread process After starting an acquisition a new thread is created to wait for the hardware interrupt indicating that the acquisition completed T
12. the trigger indicator at the lower left of the waveform display does not blink green the digitizer is not receiving valid triggers Check the trigger settings or select Auto mode in order to obtain a display of the waveform Auto mode will acquire and display waveforms according to the trigger settings if a valid trigger is present within a timeout interval If a valid trigger is not available within this interval the digitizer generates its own trigger in order to digitize and display whatever signal is at the input at that time If valid triggers are received at a high enough rate Auto mode behavior differs little from normal mode behavior on the display However if the trigger rate is too low or trigger settings are not appropriate for the characteristics of the signal the input signal will not be stable on the display This occurs because the internal auto trigger generated by the digitizer 1s asynchronous to the input signal Auto mode is often used to aid in setup when the input signal must be quickly characterized in order to determine proper trigger settings for Normal or Single mode acquisitions 4 2 8 Timebase and Memory The timebase and memory settings should be chosen together in order to Timebase optimize the desired sample rate for the acquisition E 3 Ls Div In oscilloscope mode the timebase settings range from 1 ns div to 5 S div In Memory Transient Recorder mode time windows of 0 5 ns to 40 Ks are available MAX 20000 2
13. 0 0 K samples when using a card with the 4 Mpoint memory option 4 1 00 segments EE s In order to change the timebase click on the white area in the timebase Sampling display window and select the desired timebase from the list Interval Rate Alternatively the Decrement Increment timebase selection buttons 25000ns 40000MS s may be used in order to change the timebase in steps with each click of the mouse The sample rate and sample interval resulting from the combination of memory and timebase are indicated under the Sampling section of the control panel The Memory setting shows the maximum number of points to be acquired The actual number of points acquired could be less than the maximum number set if the acquisition time window selected fills less than the selected amount of memory at the full sample rate Alternatively in Oscilloscope Mode if a slower timebase 1s selected in order to ensure that the selected amount of memory will be filled before the acquisition is complete the digitizer will reduce its sample rate as necessary This action differs from the same case in Transient Recorder Mode where preference is given to the selected sample interval In Transient Recorder Mode the digitizer will continue to allocate more memory with increasing capture times This is done in order to maintain the selected sample interval for as long a time window as is possible given the available memory When the card memory is fully utili
14. 0 hours Safety approvals CE VDE UL and CSA Materials Box of stainless steel and fan of fiberglass reinforced plastic PBT housing PA impeller HOW TO INSTALL REMOVE THE FAN UNIT ON A DIGITIZER 1 Remove the digitizer from the PC prior to installing or removing the fan unit 2 Unscrew the screws of the retaining clips on each side of the fan unit 3 Twist the fan s cable a few times in order for the 2 wires to stay together 4 Introduce the cable between the spacers A and B at the back of the digitizer 5 Push the fan unit into the back of the digitizer until the fan s box is in contact with the digitizer cover 6 Place the two retaining clips on the spacers A and B and screw again the four screws Insure that the fan unit is safely attached on the two spacers 7 Connect the fan s cable as shown in the figure below The position of the power connector can vary for different model of digitizers 8 To remove the fan unit first unplug its power cable and next unscrew and remove the two retaining clips Pull the fan unit away from the digitizer Power cable Spacer B Z User Manual Agilent Acqiris 12 bit Digitizers Page 47 of 48 10 Appendix E U1091AX03 XP103 Fan Unit for the DP Family of Modules Specification and Assembly Instructions XP3 Option SPECIFICATIONS Airflow 16 m3 h typical speed 6500 rpm maximal noise 30 dB A Nominal Voltage 5 VDC Power input 2 1 W With electronic protec
15. 1 MQ if the signal is greater than 5 V DC A 5 V limit on trigger signals should be respected although somewhat higher voltages for short time periods will not damage the unit For 1 MQ input signals up to 100 V DC peak AC lt 10 KHz are allowed 3 4 2 Trigger Coupling Trigger coupling is used to select the coupling mode applied to the input of the trigger circuitry Modes available include AC LF Reject and DC The AC LF Reject mode couples signals capacitively and removes the input signal s DC component and signals below 50 KHz DC mode allows all signal components to be passed through to the trigger circuit User Manual Agilent Acqiris 12 bit Digitizers Page 23 of 48 3 4 3 Trigger Level The trigger level specifies the voltage at which the selected trigger source will produce a valid trigger The trigger level is defined as a set voltage Using the internal trigger the level is set with respect to the midpoint voltage V m Offset voltage of the digitizer s vertical scale Internal trigger level settings expressed in 96 must be within Vm 0 6 FS where FS is the channel Full Scale All trigger circuits have sensitivity levels that must be exceeded in order for reliable triggering to occur The AC coupled mode is implemented with an auto level trigger The external trigger level can be set to values in the range 3 V Input signals up to 5 V DC can be input without damaging the circuitry The external trigger 3 dB bandwid
16. 2 Bus location Step X Crate size Step 4 Module locations How many crates do you have with activated Acqins modules Next gt gt The choice of the number of crates ranges from None up to the number of bus segments that the driver has found containing Acqiris modules If you choose None and save the resulting AqGeo map file the system will behave in its natural way without any additional user provided information If you want to give the driver information on the physical position of modules you should select the appropriate number of crates If the number of crates does not User Manual Agilent Acqiris 12 bit Digitizers Page 41 of 48 correspond to your expectations you may have hardware problems unpowered broken or badly cabled crates or modules The next step is to associate each bus segment with a physical crate The menu to do this 1s shown below E Acgiris GeoMap Wizard a x Step 1 Crate court Step Bus location Step X Crate size Step 4 Module locations In which crate are the modules with the red LED Select corect one Modules fram bus 4 are in crate H Modules from bus H5 are in crate H C Modules fram bus 6 are in crate H x Previous Mast gt Selecting a row will cause all of the LED s of modules in that Bus to be turned on RED This should make it easy to identify which crate the modules are in The third step is to specify the number of slots in each c
17. 310 dE os 1005 o 1 0 1 5 0 1 DP306 Lo LS All modules conform to Revision 2 2 of the PCI Local Bus Specification They all use the PCI Bus at 33 MHz The CompactPCI modules are compatible for either V I O 3 3 V or 5 V All of these modules are capable of DMA transfers at rates 100 MB s 3 10 2 Environmental and Physical The modules have a Declaration of Conformity according to ISO IEC Guide 22 and EN45014 and CE Marks of Compliance The American Standard MIL PRF 28800F has been used as the source for many of the characteristics specified below Those indicated with a are compatible with Class 3 as defined in that standard The front panels of the CompactPCI modules are in compliance with the IEEE 1101 10 standard Operating Temperature 0 to 40 C The above values are for the ambient temperature of the room or equivalent where the CompactPCI crate is located The temperature as measured on the board may well be significantly higher On board temperatures above 60 C should be avoided Relative Humidity 5 to 95 non condensing Dimensions DC modules conform to the 6U CompactPCI standard 233 mm x 160 mm x 20 mm DP modules 107 mm x 210 mm require a long card slot If used with the XP103 fan they can be adjusted to conform to the full 342 mm length An XP100 fan will add 45 mm to the length of any card Shock 30 G half sine pulse Vibration 5 500 Hz random User Manual Agilent Acqiris 12 bi
18. 4 SPECIFICATIOHS AZSBus Bridges alla the connection and synchronization af up to 7 OC series digtizers up to Z8 channels Acqiris recommends having the master digitizer in the center ofthe group in order to obtain the best performance possible Clack synchronization accuracy 100ps InstallRemove the 4A58u5 Bridges as follows Make sure that the screws securing each ofthe modules to the crate are not completely tightened Before inserting the amp SBusz bridge manually adjust any difference in the module separation such that the distance between the center af the connnectors corresponds to that ofthe amp SBusz bridge m Caretully insert remove the amp SBusz bridges between each pair af modules Force should not be required Tighten the screws af each ofthe modules z If desired add an 6104 Retainer on each handle to secure the 45B8us bridge against vibration It clicks inta place when fully inserted It can be easily removed by pulling an the lower half af the Retainer while sliding it off User Instructions for 2 digitizers User Instructions for 3 digitizers ASBus dual termination 0101 010z bridge B103 ABUS ASBus let termination bridge 6101 ASBus right termination bridge E102 User Instructions for 4to T digitizers 6101 ABT UL ASBus let termination bridge xBTUT 1 to 4 ASBus bridges 86100 ASBus right termination bridge 8102 nBT1US Retainer User Manual Agi
19. ION 46 9 APPENDIX D U1091AX01 XP100 FAN UNIT FOR THE DP DIGITIZER FAMILY 47 10 APPENDIX E U1091AX03 XP103 FAN UNIT FOR THE DP FAMILY OF MODULES 48 User Manual Agilent Acqiris 12 bit Digitizers Page 4 of 46 1 Out of the Box 1 1 Message to the User Congratulations on having purchased an Agilent Technologies Acqiris data conversion product Acqiris digitizers are high speed data acquisition modules designed for capturing high frequency electronic signals To get the most out of the products we recommend that you read this manual carefully We trust the product you have purchased will meet with your expectations and provide you with a high quality solution to your data conversion applications 1 2 Using this Manual This guide assumes you are familiar with the operation of a personal computer PC running a Windows 2000 XP or other supported operating system It also assumes you have a basic understanding of the principles of data acquisition using either a waveform digitizer or a digital oscilloscope The manual is divided into 5 separate sections To understand the elements of operation for the module it 1s essential that you read them all Chapter 1 OUT OF THE BOX describes what to do when you first receive your new Acgqiris product Special attention should be paid to sections on safety packaging and product handling Before installing your product please ensure that your system configuration matches or e
20. PCI device node automatically when your computer is restarted Note that the permissions that are set in this example m 666 gives access to the Acqiris instruments to all the users This may not be what you expect and these permissions can be adjusted to fit your requirements The basic rule 1s that any user that wants to use the Acqiris instruments has to get read and write access to dev acqrsPCI 2 3 1 Environment variables for the Firmware Automatic loading of the firmware needed by 12 bit analyzer and averager modules relies on the environment variable AcqirisDxDir pointing to the directory containing the file AqDrv4 ini which in turn points to the directory containing the Firmware bit files Therefore assuming that your Firmware 1s in usr local AcqirisLinux Firmware and that AqDrv4 ini is in usr local AcqirisLinux demo then you must edit AqDrv4 ini so that it contains the line fpgaPath usr local AcqirisLinux Firmware Then if your shell is csh or tcsh modify the etc csh login file to contain the line setenv AcqirisDxDir usr local AcqirisLinux demo or if your shell is bash ksh zsh or sh modify the etc profile file to contain the lines AcqirisDxDir usr local AcqirisLinux demo export AcqirisDxDir 2 4 Installing the Hardware 1 Turn off the power of the PC and the crate in the case of a CompactPCI module N CAUTION For PCI modules the PC may have to be unplugged to ensure that the PCI bus has no power available However
21. R application a demonstration program for the Acqiris AP235 AP240 Analyzers o the DemoAPX01 application a demonstration program for the Acqiris AP101 AP201 Analyzers o the DemoTC application a demonstration program for the Acqiris TC840 TC890 Time to Digital Converters o product data sheets User Manual Agilent Acqiris 12 bit Digitizers Page 6 of 48 o full installation procedures for use with Microsoft Windows National Instruments LabVIEW RT Wind River VxWorks IVI COM C and Linux software e A declaration of conformity e Optional documentation such as a model dependent document giving Specifications amp Characteristics a Calibration Certificate or a Performance Verification After carefully unpacking all items inspect each to ensure there are no signs of visible damage Also check that all the components received match those listed on the enclosed packing list Agilent cannot accept responsibility for missing items unless we are notified promptly of any discrepancies If any items are found to be missing or are received in a damaged condition please contact the Agilent service center or your local supplier immediately Retain the box and packing materials for possible inspection and or reshipment 1 8 Warranty All Agilent Technologies Acqiris Digitizer products are warranted to operate within specification assuming normal operation for a period of three years from the date of shipment It is recommended that yearly calibr
22. TR OUT Signal occurs after an accepted TRIGGER MMCX I O B User configurable see below The I O A and I O B signals are 3 3 V compatible CMOS This means that on input low 1s 0 7 V and high must be in the range 1 7 V 5 0 V An unconnected signal will be high This definition ensures TTL compatibility On output the low level will be in the range 0 V 0 7 V and the high level in the range 1 7 V 3 3 V for HiZ The high level output will typically give 0 8 V into 50 Q The I O A or B connectors can be used for an Enable trigger input or the following output signals 10 MHz reference clock To ensure good rise time characteristics the output impedance is 50 Q in the case of the DC RevB units this is only available on I O B This signal can be used as an input to 1 or 2 using a T split CLK IN connectors Note This signal is the internal 10 MHz and is not available if the External Reference Clock is in use Acquisition skipping to next segment Acquisition is active Trigger is armed 3 9 External Trigger Output When the digitizer is ready to be triggered and a valid trigger signal occurs a trigger output is generated for external use It is always available on the Front Panel Trigger Out MMCX connector The pulse ends when the data acquisition for the trigger in question is complete NOTE The External Trigger Output functionality is implemented in the hardware No Trigger Out signal occurs for software genera
23. U gopnuxes odroverpor make clean all to generate a new kernel module from scratch make install to copy the kernel module where it should reside this last command require super user privileges In the end the loadable kernel module should be present in the system s loadable kernel modules directory You can verify that it is present by running ls L lib modules uname r extra acqrsPCI ko For Debian users in order to compile the kernel module on a system the kernel packages that match the current kernel image must be installed For instance on a Debian etch 4 0 system 686 the required packages are Linux image 2 06 69596 linux image 2 6 18 4 6860 linux headers 2 6 686 linux headers 2 6 18 4 linux headers 2 6 18 4 686 lritusx kbounrld 2 106 19 Note that this version of the loadable kernel module had been tested on Linux kernel versions up to 2 6 18 However starting with kernel 2 6 17 a few kernel functions relating to the device classes are no longer available to proprietary modules Thus automatic creation of the dev acqrsPCI node has to be done manually in the etc rc local file see 2 3 2 2 User Manual Agilent Acqiris 12 bit Digitizers Page 13 of 48 2 3 1 1 2 Compiling for Linux kernels 2 4 The makefile will try to guess where they are located If it fails see the instructions inside the makefile itself to specify manually where these kernel header files are located The path variable INCLUDEDIR in the ma
24. USER MANUAL AGILENT ACOIRIS 12 BIT DIGITIZERS Models covered DC440 DC438 DC436 U1066A DP310 DP308 and DP306 U1070A GE Agilent Technologies Manual Part Number U1092 90005 Edition C RevJ December 2007 he information in this document is subject to change without notice and may not be construed in any way as a commitment by Agilent Technologies Inc While Agilent makes every effort to ensure the accuracy and contents of the document it assumes no responsibility for any errors that may appear All software described in the document is furnished under license The software may only be used and copied in accordance with the terms of license Instrumentation firmware is thoroughly tested and thought to be functional but it is supplied as is with no warranty for specified performance No responsibility is assumed for the use or the reliability of software firmware or any equipment that is not supplied by Agilent or its affiliated companies You can download the latest version of this manual from http www agilent com by clicking on Manuals in the Technical Support section and then entering a model number You can also visit our web site at http www agilent com tind acairis At Agilent we appreciate and encourage customer input If you have a suggestion related to the content of this manual or the presentation of information please contact your local Agilent Acqiris product line representative or the dedicated Agilent Acqiris Technic
25. Who needs a Geographical Map of Modules The GeoMapper application gives the user the possibility of telling the Acqiris driver crucial details of the physical position of modules when this information cannot be deduced directly It allows the driver to correctly adjust trigger and clock delays between the different modules of an AS bus multi Instrument and arrange the modules in an intuitive order The GeoMapper application has been implemented as a Wizard with the goal of learning the physical position of each module of a multi bus system The driver already knows the logical Bus and logical Slot numbers of each Acqiris unit present However because of varying conventions for the compactPCI slot arrangement on a bus this is not sufficient to determine the physical position Furthermore with the aid of the map the software can ensure that the modules of an Auto defined multi Instrument will be ordered to correspond to increasing physical slot number NOTE The unusual slot numbering convention of the CC121 is documented in the CC121 CompactPCI Crate User Manual The CC10X crates have a simpler slot numbering convention that the Acqiris driver already takes into account CompactPCI Crates from other manufacturers represent an unknown element NOTE The GeoMapper is of use for some AS bus systems in CC121 crates and perhaps crates from other manufacturers CC121 crate configurations with both an Acqiris acquisition module in one of the last 7 slots a
26. a minimal amount of power For complete technical specifications concerning your particular digitizer please refer to the product s Specifications amp Characteristics In addition we maintain up to date versions of all product data sheets on our web site http www agilent com find acgiris The data sheets are available in pdf format and are best viewed using Adobe Acrobat software If you have trouble accessing our web site or viewing the data sheets please contact your nearest sales office User Manual Agilent Acqiris 12 bit Digitizers Page 18 of 48 3 2 Channel Input 3 2 1 Coupling amp Impedance The normal BNC input channels of all of the 12 bit digitizers provide a high quality DC coupled 50 Q input impedance with better than 1 precision They are ideally suited for use with 50 transmission lines coax high bandwidth low impedance typically 500 Q probes or active probes The Direct HF SMA inputs of the DC440 and DP310 are AC coupled at 50 O input impedance The AC cutoff frequency is MHz 3 2 2 Input Protection For the normal BNC inputs the amplifiers are protected against over voltage signals Input signals up to 10 V DC or 2 0 W RMS can be input without damaging the front end electronics The Direct HF inputs accept signals up to 15 V DC with an AC component limited to 2 0 V RMS without damaging the circuitry 3 2 3 Mezzanine Front end The front end electronics are all mounted on a removable mezzanine
27. al Support ACOIRIS SUPPORT agilent com Acgqiris Product Line Information USA 845 782 6544 Asia Pacific 61 3 9210 2890 Europe 41 22 884 32 90 O Copyright Agilent 2007 User Manual Agilent Acqiris 12 bit Digitizers Page 2 of 48 CONTENTS 1 OULOE THE DO X 3 eo ere eoruni re ren e rive ere ese re Udo 5 il Message tothe U Cp saos M LIMEN UAE T MM UL AD 5 1 3B SIR US Main eee oe ee 5 1 3 Conventions Used ini This Manual siecctssckencseatcarsQanedesstebekeredsocddenshubease tecndasthedeberscsocddenseubensads 5 I Mode NIMES RR T Ui 6 Rea perme BS Ese cc a nyc care a6 Eiko KB genres ea em ere rs eT nts ee eee ne scenes ee 6 1 6 Warning Regarding Medical Use eeeeesseeesseeeeeeen nna aaa ananas 6 lu PAC KA CTI and Handini 25h pane ctiba E E E E A EEE 6 IE M Cocina muteoeuimaneteubaounia tooluoksvealaaahibustaheisnsens 7 1 9 Warranty and Repair Return Procedure Assistance and Support eeeeeeeuuuuuse 7 T 10 Syse COUT CIC INS estaba tata a aa iie seo bo eaieul ocala eee Cor SEE br eiu macs 7 Kr Transpor S DIDP ninen EE a EET E EE 8 Te N A aa A UL E 8 e ee AS E 421 1 A E A A EA E A A E IA ee O E A P A E 9 I4 3Disposaland RG Cy CLIN nen daa MM MEE TE 9 P NEM id PESE E TION cacan aa Cetseatevsuscunsuaseaaneeetesd E Aa 10 Zl AHOSDAKOICATA Tins tethers RC HR OR ERROR B e ARR Best ent M etes 10 i IC414 Hardware installation ints cccc ccc ccccccccccceeeeeeeee
28. and vertical controls shown on the zoom display window To the right side of the zoom window click on the Horizontal button then modify the zoom expansion factor by clicking the In or Out buttons The vertical blue cursor or box depending on the zoom factor shown on the main display window indicates the center point and range of the zoom The vertical box or line can be dragged right or left with the mouse in order to re position the center point of the waveform displayed in the zoom display window Alternatively the right and left arrows at the bottom of the zoom display window will reposition the horizontal center of the zoom In order to expand the zoom region vertically select the Vertical button on the zoom display and click the In Out buttons Alternatively the up down arrows on the scale indicator just below the vertical button can be used When the vertical scale is expanded the top and bottom lines forming the blue box in the main display window show the extent of the vertical zoom region The vertical position of the box and thus the data region shown on the zoom display may be changed by moving the box vertically with the mouse or by clicking on the up and down arrows at the left of the zoom display window When expanding a waveform to the point where individual data points are seen it may be desirable to use the Connect data points option under the Options menu in AcqirisLive When this option
29. apabilities but display the settings slightly differently For example in Transient Recorder Mode the user selects the Full Scale Range of the amplifier whereas in Oscilloscope Mode the user selects the input voltage scale set in Volts Div The desired mode is selected using one of the two buttons shown at the top of the control panel The distinction between the control panels for the two operating modes can be seen in the images below In both modes it is possible to set the memory depth and the sample speed independently within the limits of the maximum available memory However the two modes differ in the following way In Oscilloscope Mode the user selects the time window time per div and the sampling rate will be adjusted to the fastest possible within the limits of the available memory The maximum available memory is programmable In Transient Recorder Mode the user selects the capture time window the sampling rate or the number of samples When selecting the capture time window the number of samples is adapted keeping the current sampling rate and number of segments up to the maximum available memory on the card When selecting the sampling rate the number of samples is adapted keeping the current capture time window and number of segments up to the maximum available memory on the card When selecting the number of samples the capture time window is adapted keeping the current sampling rate and number of segments User Manual Ag
30. at the trigger has occurred the acquisition is complete and the data is waiting to be readout The user can override the default functions and program the LED color in an application specific manner 3 5 External Clock and Reference For applications where the user wants to replace the internal clock of the digitizer and drive the ADC with an external source either an External Clock or an External Reference signal can be used The Clock or Reference signals can be entered into the digitizer by the dedicated MMCX User Manual Agilent Acqiris 12 bit Digitizers Page 24 of 48 When using a continuous External Clock the user must ensure that the input signal has a frequency between 100 MHz and 400 MHz The input signal must have a minimum amplitude of at least 1 V peak to peak into 50 Q at the front of the digitizer The transitions of the clock are defined with the aid of a threshold that is user selectable in the range 2 0 V 2 0 V The signals should not exceed 5 V amplitude For a detailed discussion on the programmed use of the external clock refer to the Programmer s Guide For applications that require greater timing precision and long term stability than 1s obtainable from the internal clock a 10 MHz Reference signal can be used The External Reference is nominally at 10 MHz However frequencies in the range 9 0 MHz 11 0 MHz will be accepted If you do this you may need to correct for the difference in your application since the digit
31. ation be made in order to verify product performance All repairs replacement and spare parts are warranted for a period of 3 months A 5 year repair warranty is available as an option Agilent endeavors to provide leading edge technology that includes the latest concepts in hardware and software design As such software and firmware used with the products 1s under continual refinement and improvement AII software and instrument firmware is supplied as is with no warranty of any kind Software and firmware is thoroughly tested and thought to be functional at the time of shipment At Agilent s discretion software and firmware may be revised if a significant operational malfunction is detected Products supplied but not manufactured by Agilent are covered solely by the warranty of the original equipment manufacturer In exercising this warranty Agilent will repair or replace any product returned to the Agilent service center within the warranty period The warranty covers all defects that are a result of workmanship or materials This excludes defects that are caused by accident misuse neglect or abnormal operation The purchaser is responsible for returning the goods to the nearest Agilent service center This includes transportation costs and insurance Agilent will return all warranty repairs with transportation prepaid 1 9 Warranty and Repair Return Procedure Assistance and Support Agilent acquired Acqiris SA and its product lines i
32. ator with a green backlight For the DC440 and the DP310 the AC coupling setting is used to choose the Direct HF Input SMA Connector In DC coupling the Standard Input BNC is in use and all frequency components are passed through the input The input voltage offset control applies an offset to the input amplifier in order to better digitize and display signals offset away from 0 volts Signals riding on a DC level can be most accurately characterized when the offset is adjusted so that the acquisitions are made about the midpoint of the digitizer s Full Scale Range and when as much of the 12 bit ADC range is used as possible The ability to select an offset voltage enables accurate measurement when offsets are present in the signal The Impedance selection is not active for 12 bit digitizers since only 50 Q 1s allowed The Adv button in this section gives access to the choice of hardware bandwidth limits for the channel 4 2 6 Trigger Trigger characteristics are set using the settings in the control panel Trigger Edge class section The trigger source setting can be either Internal trigger on any one of the input channels or External trigger on an external input The trigger 704e BP318 Chi MC source is indicated in the display by the name appearing under Source In order to select the trigger source click the drop down source menu in the trigger Source section of the control panel and choose the desired one Notice that wh
33. ce ASBus multi module sync COTITOITST lOA Q DC 440 block IOB Qc diagram Progr atten Programmable attenuator LPF Low Pass Filter Progr data proc Programmable data processing The Acqiris DC4xx digitizer cards DC440 DC438 and DC436 are CompactPCI PXI compliant and require an appropriate CompactPCI crate The DP3xx digitizers DP310 DP308 and DP306 are PCI modules that plug directly into a vacant PCI slot in a PC The PCI Bus is a well defined industry standard with a 32 bit bus operating at 33 MHz The digitizers are fully programmable over the PCI bus and deliver oscilloscope like performance Data captured by the digitizers can be transferred to a host processor either in the PC in the crate or interfaced to the crate over the PCI bus at speeds up to 100 Mbytes s DCAxx digitizers occupy a single slot of a GU CompactPCI crate and they comply with the 6U CompactPCI standard PXI compliant Acqiris digitizers are designed to provide superior measurement precision and accuracy Key acquisition specifications such as DC accuracy integral and differential non linearity have been optimized to deliver maximum measurement fidelity Careful circuit layout custom IC s and special packaging techniques have all been employed to reduce overall system noise The use of custom IC s also dramatically reduces the total number of discrete components required This has tremendous benefits on reliability and also allows the modules to use
34. cessor 150 B MHz Pentium higher recommended Memory 64 MB RAM The previous number is a very rough estimate Assuming that you are using AcqirisLive or an application of your own that operates on the acquired data it seems reasonable to ask for 10 times the total acquisition memory that you will be using at the same time in the application Performance is likely to be degraded if less memory is available User Manual Agilent Acqiris 12 bit Digitizers Page 7 of 46 Display resolution At least 800 x 600 pixels and 256 colors for use of AcqirisLive or AcqirisDemo Operating System Microsoft Windows 2000 XP including 2003 Server Wind River VxWorks 5 5 1 and 6 4 and Linux with kernels 2 4 and 2 6 Support for Windows 95 98 NT4 1s included as is since these operating systems are no longer supported by Microsoft Hard Drive Space 20 MB Minimum CD Drive or any method to copy the software installation files from CD to the hard drive such as LAN floppy drive etc LabVIEW A driver is available for National Instruments LabVIEW versions 7 lor 8 0 LabVIEW RT A driver is available for National Instruments LabVIEW RT version 7 1 or higher The VISA driver must be version 3 0 or higher MATLAB The MEX interface can be used with MathWorks MATLAB 6 5 or a newer version Visual BASIC The interface files and examples are available for Microsoft Visual Basic versions 5 or 6 and the interface files only for NET Tornado The example fil
35. d real time single shot waveforms are used in other applications and one of their important specifications is the sparkle code rate This is the probability that a sampled data point differs from its true value by more than a specified deviation For the purposes of this discussion we take the allowed deviation to be 3 1 FS 128 ADC counts At lower sampling rates 200 MS s all of the 12 bit digitizers show a low occurrence of sparkle codes The sparkle code rate is 10 typical at 200 MS s However at sampling rates above 200 MS s the chances of a sparkle code occurring increase with the sampling rate The sparkle code rate reaches 10 typical at 400 MS s 3 4 Trigger The trigger settings applied to the digitizer are used to determine the time at which the device will stop acquiring data The various trigger settings are outlined below 3 4 1 Trigger Source The trigger source can be a signal applied to either a Standard Input Channel internal triggering or the External Trigger Input Signals on the HF inputs cannot be used The digitizers provide a front panel BNC External Trigger Input The External Input provides a fully functional trigger circuit with selectable impedance 50 Q or 1 MQ coupling level and slope as for the Internal Triggering source In addition the External Trigger Input can be used to generate a TV trigger The circuitry provides an overload protection that will automatically switch the coupling from 50 Q to
36. d connector into the PCI module socket furthest from the PCI card internal base connector and the Black connector into the next socket If you intend to use 64 bit 66 MHz transfer to maximize data transfer speed you should cable a bundled link using two standard cable pairs and both the LO and L1 pairs of connectors You should also make sure that you configure the PXI 8570 M66EN Jumper correctly 2 1 2 IC414 Windows software installation Linux users do not need to read any further since there 1s no special software installation Windows users should have the hardware installed as noted above This software installation should be done before any Acqiris modules are placed in the CompactPCI crates This may mean that you have to remove the module from the crate as delivered The crate should be turned on first followed by the PC If the cabling and start up sequence is done correctly there will be no LED illuminated on the PCT unit connected pair and the LED s of the PXI connected pair will be lit For Windows XP installation Select the Control Panel under Settings in the Start menu Then if you are using the Category View select Printers and Other Hardware After this for both Category and Classic views go to System and then display the Hardware tab to get access to the Driver Signing menu Since neither the AdLink nor the Acqiris driver has been submitted for Windows Logo testing you must select either the Ignore or Warn action The resul
37. e limit on the total amount of data allowed in any single Autostore acquisition series When using segmented memory with Autostore a waveform is considered to be a complete set of acquired segments When storing Amplitudes it is possible to write each segment as a separate column of data in the waveform file This is achieved by clicking the check box option Segments as columns in the Autostore settings window Formatting with segments in columns in Amplitude format is limited to 200 segments The Binary file format selection provides the fastest storage performance and generates the smallest files on the hard drive Binary files can be subsequently converted to either Raw ADC values or to Amplitude values using the Data Format Conversion utility provided with AcqirisLive Selecting the Write files at end option acquires all waveforms into memory first before converting to the selected format and writing the data to disk This option allows for faster data capture times Selecting the Show waveforms allows the user to see the waveforms before writing them to disk When all parameters are selected click OK and then select Normal Auto or Single acquisition mode When the waveforms are recorded a progress bar will appear to show the status of the acquisition and of writing the data to disk The Autostore function can be aborted from the progress bar Raw ADC values are the raw 16 bit ADC levels in ASCII format The channel s gain and offs
38. e ome 19 3 2 4 Ba dwidth and Rise LIte ue EE pte Etpe ER pte eI es tuat 19 3 2 5 Input volage and OTSE eee eter Eve eet teet Pint na ete ras 20 3 2 6 Neracal Rosolo concise taba eS a Dud M ES c ULM empta te NOD EDUC OUS 20 SLT DC Accuracy and Lineattby a usd tost eite Eo pce ettet ve tested tet EA ettet ve tuat e ten ies 20 Suse SO XCCOHISBHOR ge eC eae eee a DL LIE MC n ee eee EI 21 3 9 High Resolution Sample Rate ccccccccccccccccscceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseseeeeess 21 SS A ANcdulstton MEMO odisea it bae tito diu sd bande boc a E ecd c Geop Md 22 3 9 9 Single and Sequence Acquisition Modest asta nens pa a eeu n s Peas in be ens tewieonoes 27 3 3 4 Bini Dc eer ea en ee aE 23 3 3 5 Tre Dgse JS dH A Ce ae A O en ae eee ee eee 2 5 3 3 6 BO aT NG COS TALS sees vats narra aE N Diocese M erdret A Ds ute ve EEE 23 S57 EM eiu 5 ees P aR E BRILON HUN APR EH URN ARUM NUR SOLUTA HM RN ON 23 3 4 lUo CInSOULCO utebare o EITO EA AE fisco eate Ue iuro 23 3 4 2 Tripser C oUDIIfI9 3 5 x co resa oe ee se ed eee aen qoc etes o mo mus lesus as 23 3 4 3 DS OCP Te s Mc 24 3 4 4 Edgeio SECS ONE ee Dati ica bed uiro bsc a AM s cite A Ute eds 24 3 4 5 Presand POSGTEHPSeE DOLI ce aeter tn Oe 24 3 4 6 BS M utres p MN I RN 24 User Manual Agilent Acqiris 12 bit Digitizers Page 3 of 46 34 7 Erreger so ob uetus D LM E het de 24 3 External CIOCK ANC Referente eot ap EDD ERN A EM MM DAE eG Ba 24 BiG
39. eeeeeeeeeeeeeeeeeeeeseeeseeseeseeseeeeeeess 10 2 1 2 IC414 Windows software installation sseerrrrrr 10 2 2 Installing the Software under Windows esses nnns 11 2 Egit ER 11 2 23 Moltiple Ver ONS ornini itunes eodeni tuin boe sime abes ctun Lese 11 2 255 TosStallabtOEi sie oun co Ent icc our usd otn te ed Itev vus ae eiue ot deu A 12 2 5 Tnstalline the Software tor LiM eis o obti ie ers BG ER b ee eh alee arse Mn ieee eene 12 25d lis Environment variables for the Firmware ccccccccccccccccsseseeeceeeeeeeeeeeeeeseseeeeseseseeeeseeees 15 2 dTustallios the ae Ww ate d led ii adeste desiit atari desea clad dei latch ie 15 2 5 AMER AN os eRe Ree ono RTT Lene RC Soren One t eode a Loon concerto A ios 16 Dols MVE O WS 2000 srcane cae sdiasaeena li ico bloc scott coa idtos pena di o babc scene eed 16 2 52 WON eb esce rtt tasted edu so cdd codem Te aw hry err rena Ludus 16 2 05 JEaD NAE ail R Rees bue b ete iai ee ener sb on etatis letus costae disait ee eee ee 17 2 5 Tstalipne the IVECOM C Dii yerisin a e g EOE E NG T EO t us 17 2 8 Distribution for Windows 2000 XP and Linux eec t7 3 PRODUCT DESCRIPTION arnan E ePi 18 Falk OVON O Wy oaa mp 18 S04 Channel INNO eee mere enn eee a A A 19 32k Couplus C Drpe dati e oer sti r ita se men i tud 19 3 222 lapat OlC COM sect Oc ute tis cect TTD A E MEET 19 512 9 Mezzanino Frontend eee iere tero e teet D eroe tee oA ete dba tes
40. en external trigger is selected the controls for the trigger termination 50 Q or 1 MQ are enabled in the Coupling section Select the desired termination for the external trigger The Coupling section also contains a selection for AC or DC coupling AC coupling on the trigger sets the trigger circuit to an AC Low Frequency Reject mode Use the Level section to set the desired trigger level The relationship between coupling trigger source and trigger level was discussed in section 3 4 3 Trigger Level The trigger Delay setting positions the acquisition with respect to the trigger Pre trigger values are negative and are selectable in the range of 0 to 10 timebase The value 10 timebase is equivalent to the time window or capture time 100 pre trigger is achieved by setting Delay capture time A 100 pre trigger delay means the trigger point is at the right edge of the display and all of the data in the acquired waveform were captured just prior to the trigger event Maximum Post trigger delay settings depend on the sample interval used Post trigger delays are adjustable up to 100 Mpoints When a Slope box is shown next to the delay section selecting the trigger slope 1s achieved by depressing either the positive or negative slope buttons User Manual Agilent Acqiris 12 bit Digitizers Page 33 of 48 4 2 7 Acquisition Mode The acquisition mode of the digitizers is selected using one of four acquisition
41. eraged This gives 13 bits of vertical resolution which means that for FS 1 V the smallest difference between 2 data samples will be 0 122 mV The DC440 RevB and DP310 RevA units show their revision number in the string returned by using the AcqrsD1 getInstrumentInfo id Options string function call DC440 s with serial numbers below 18800 and DP310 s with SN lt 21500 fall in this class Model Maximum Sampling Rate pum 13 bit aa DC440 DCA40U1066A 001 066A 001 200 200MSS DC440 RevB 110 MS s DC438 U1066A 002 DC436 NA DP310 U1070A 001 200 MS s DP310 RevA 110 MS s DP308 U1070A 002 DP306 U1070A 003 NA 3 2 7 DC Accuracy and Linearity All of the 12 bit digitizers use low noise front end electronics in order to ensure voltage measurement is made with accuracy and precision DC voltage accuracy at 0 V offset is better than 0 5 of the input voltage full scale for FS gt 1 V and1 FS for the more sensitive ranges The differential linearity is better than 0 5 LSB User Manual Agilent Acqiris 12 bit Digitizers Page 20 of 48 3 3 Data Acquisition The table below summarizes the characteristics discussed in the sections that follow Memory Segments channel Granularity s000 lt 025 points Rate channel channel DP310 Model Max Max Default Default Maximum Maximum SR Minimum Sampling Converters Memory Maximum Optional Segments Adjustment Deadtime DP308 200 MS s 3000 DP306
42. es are useable with Wind River Tornado 2 2 1 1 11 CAUTION Cards can be safely transported in their original shipping packages DC cards can be transported when properly mounted in a CompactPCI crate The transport of DP cards mounted in a PC is a more delicate issue Because of their mass the cards can vibrate loose unless they are properly secured and braced DP cards held only in the front and on the bottom should not be shipped in their PC However properly mounted DP cards with XP103 or XP105 fans can be sufficiently well held the Adjustable retainer must be used so as to hold the card in place Transport amp Shipping To package the instrument for shipping Step Notes 1 Place the instrument in its original packaging materials If the original packaging materials are not available use a professional packaging service Contact your Agilent Service Center for more information 2 Surround the instrument with at least 3 to 4 inches 8 to 10 cm of its original packing material or bubble pack to prevent the instrument from moving in its shipping container 3 After wrapping it with packing material place the instrument in its original shipping container or a strong shipping container that is made of double walled corrugated cardboard with 159 kg 350 Ib bursting The shipping container must be large and strong enough to accommodate your instrument and allow at least 3 to 4 inches 8 to 10 cm on all sides for packing ma
43. et are needed in order to obtain the signal level in Volts The required information to convert the Raw ADC values to voltage is included in the header information of each Raw ADC ASCII file or in the awh file accompanying the binary files In order to convert the Raw ADC values into Volts the following formula should be used V vGain data vOffset The Amplitudes V selection stores the waveforms as voltage samples in ASCII format This data has already been adjusted for gain and offset and can be directly read out as a voltage However it requires roughly twice as much space as Raw ADC value data For the sequential acquisition mode the segment time stamps are also stored when waveforms are saved using the Autostore and Save Waveform functions Data stored in binary format with Autostore must be converted before it Data Format Conversion i IDE x can be imported into a data processing package or a spreadsheet e g UT Excel The Data Format Conversion option is found under the store menu XE Gu c SAcqinsLreesD ata Browse Select Data Format Conversion in order to bring up the following window The acquisition must be stopped in order to access this menu Raw ADC values To convert the binary data simply select the source folder where the data 1s located select the output format and click OK All binary data files found in the source directory will be converted to the desired format If you are writing amplitudes with
44. files you should e create the folder firmware in the NI RT system directory using the file transfer application e select the FPGA files from AcqirisDxRoot Firmware you want to copy to the target and upload them into the firmware directory Restart the target after finishing the file transfers Restart the MA X Explorer and you should have Acqiris digitizers detected in your PXI system 2 7 Installing the IVI COM C Driver Please install Acqiris software for Windows first Then the Acqiris Software CD Autorun program gives access to two installers IVI Shared Components 1 4 JVI COM C IviAqD1 driver These must be installed in the order shown above For more information you can then consult the Readme txt file in the VI Drivers IviAqD1 folder or the documentation through the program shortcut present under Ivi IviAgD 1 2 8 Distribution for Windows 2000 XP and Linux The manuals ReadMe txt file contains a list of files to be found after a complete installation of Acqiris software on Windows systems Similarly the ReadMeLinux file gives the list of files corresponding to that installation User Manual Agilent Acqiris 12 bit Digitizers Page 17 of 48 5 Product Description 3 1 Overview INPUT 1 Ear gt A Data ELA m I HFINPUT1 i we ex Progr aie INPUT2 3 p ENE Opt C Amp memory LE HFINPUT2 C ext e Local TRIGGER IN Bus TROUT G PCI Bus Ext CK Ref input PCI CLKIN Interfa
45. he card into it Be sure to ground yourself by touching the grounded PC frame and avoid touching any components on the card Make sure that the grounding of the card s mounting bracket to the back panel rail of the computer is done correctly Close the PC Connect the module to the CompactPCI crate controller 3 Turnon the power of the crate s 1f present and then the PC and start the operating system User Manual Agilent Acqiris 12 bit Digitizers Page 15 of 48 NOTE Acqiris digitizers are equipped with a LED If this LED is not glowing orange or red when the power is N applied there is a severe problem Either the module is broken or the necessary voltages for its use are not available N NOTE For proper system operation when using the IC200 IC414 or other PCI extension interface to connect a CCIOX crate to a remote PC the crate must be powered on before the PC in order for the PC BIOS to recognize the presence of the CompactPCI crate 4 If devices were installed using a previous version of Acqiris software the instruments in these logical positions may still appear as Unknown Devices This can be changed to the new Acairis type category with the Grey Diamond icon by Uninstalling the device and then Installing again Instructions on this procedure can be found in the ReadMe txt file in the manuals folder of your Acqiris software installation 2 5 After Restarting 2 5 1 Windows 2000 Under Windows 2000 you must login with adminis
46. his thread is put to sleep and wakes up upon reception of the interrupt from the instrument or after a 2 seconds timeout Please note that switching the DMA data transfer mode off precludes the use of acquisition interrupts The i switch will therefore be ignored when n is used Transient recorder mode The application will start in the Transient Recorder mode as opposed to the oscilloscope mode In this case if a file name of an AqConfig setup file is given on the command line it will be loaded Simulation Mode Simulation mode allows you to run AcqirisLive without having any digitizer installed in the PC Temperature Update The internally measured temperature of the currently selected module is normally displayed Using this switch turns this feature off Acquisition State This switch turns on the display of the current acquisition state Stopped Ready Started Reading Data ready This is helpful when running with time consuming settings e g many segments overlaid many channels large records etc but will slow down the overall performance Multi instruments By default AcqirisLive tries to detect instruments connected through AS bus and will initialize any connected digitizers as a multi instrument This behavior can be inhibited by the x switch in which case any AS bus connector will be ignored User Manual Agilent Acqiris 12 bit Digitizers Page 40 of 48 gt gt 5 Running the GeoMapper Application 5 1
47. i instruments Operation Mode Acqiris averagers can be operated in Averager Mode or in standard Digitizer Mode AcqirisLive operates in either mode but since these are mutually exclusive only instruments that support the chosen mode are accessible in any given mode E g only averagers are accessible in Averager Mode while both digitizers and averagers are accessible in Digitizer Mode The operation mode can be switched within the application By default AcqirisLive starts in Digitizer Mode Calibration Before operation the instruments must undergo an internal calibration As this calibration can only proceed sequentially for each channel the initialization time of AcqirisLive can become significant for systems with many channels Therefore it can sometimes be desirable to be able to start the application quickly by skipping the calibration which must then be done manually before collecting correct data DMA Data Transfers By default data transfers on the PCI bus between the digitizer memory and the PC are done in DMA Direct Memory Access mode which allows the fastest transfer speeds up to about 130 MB s peak 100 MB s sustained acquisition data rate These very high data rates are not well supported by all hardware configurations PC motherboard and system hangs due to endless retries on the PCI bus have been observed on some machines Such problems disappear when switching DMA mode off data transfer rate 1s then about 2 8 MB
48. igitizer is now installed 5 To remove the digitizer it is necessary to first release the three screws R and pull back the adjustable retainer Spacer A Screws R Power connector on the internal R edge of the digitizer N Screw R Power cable Spacer B Adjustable retainer User Manual Agilent Acqiris 12 bit Digitizers Page 48 of 48
49. ilent Acqiris 12 bit Digitizers Page 30 of 48 Oscilloscope Mode Transient Recorder Mode Instrument Control 2a x Instrument Control lol xl Instrument Setup Store Options Help Instrument Setup Store Options Help E 15600 crate 3 pos 10 Finder ET 3 15500 crate 3 pos 10 Finder DP310 Ch1 Adv DP310 Ch1 Adv Input Voltage Scale Coupling Input Voltage Full Scale Coupling B Be Bo Bev Input Voltage Offset Impedance Input Voltage Offset Impedance E 0 00 V Son IMQ o ooo 0 00 V Son IMD Trigger Adv Level 1 EN zd im 0 00 V 0 000 0 00 V Pay m Delay Delay Slope Y c 0 00 s AN E 0 00 s AN Timebase Time Window 5 uis Div ER 50 0 ps Memory Sampling Ady MAX 20000 20 0 K samples Interval Rat 2 500 ns 400 MS s s E E 1 00 segments E H i Edge class Source DP310 Ch1 Coupling Sampling Memory Interval Rate ii 20000 20 0 K samples l 2 5000 ns 400 00 MS s 1 00 segments Fea Acquisition Acquisition STOPPED r STOPPED TT AUTO NORMAL SINGLE STOP AUTO NORMAL SINGLE STOP 4 2 2 Displaying Multiple Traces If multi channel modules or several single channel modules are installed on the PCI bus multiple waveform displays one from each installed channel are overlaid on the display The current channel is selected by clicking on the channel name within the upper portion of the control panel The vertical setti
50. is selected larger data points are drawn on the display and a line connects each point User Manual Agilent Acqiris 12 bit Digitizers Page 35 of 48 The main display window contains a drop down selector that controls the display type for both the main display and the zoom window There are two modes available the Live Display or the Persistence Display When persistence display is selected all points drawn to the display windows remain on while new points are added from subsequent acquisitions This mode is particularly suited for examining the jitter on an edge of a periodic signal as shown in the image below a 1s 100 my 410 ADC bi per Division DP31 49940 49960 4 9980 50020 5 0040 5 0100 i To clear the display in persistence display mode press the Clear button that appears on the main display window 4 3 Top Line Menu of AcgirisLive The top line menu contains functions offering additional utility to iol xj the AcqirisLive application Provisions are included for storing tostrument Sete Slama means ele instrument setups waveforms converting the format of stored data files identifying models and versions and in the Options Menu calibrating the digitizer extended control of event acquisition and controlling the display properties These possibilities are discussed in the next few sections 4 4 Setup The Setup menu allows you to store and recover instrument configurations When you store a configuration the
51. ish to send it You may also add comments Uncheck the box if you do not want to register your installation After the software installation is complete you can either accept the suggestion to restart the computer or you should shutdown your computer and proceed with the hardware installation 2 3 Installing the Software for Linux The Acqiris software is ready to install on Linux systems running kernels 2 4 and 2 6 The following archives all contain the driver and library compiled with the gcc version shown AcqirisLinux 3 2a gcc 3 3 tar gz compiled under Debian sarge 3 1 with gcc 3 3 AcqirisLinux 3 2a gcc 3 4 tar gz compiled under SL 4 4 with gcc 3 4 AcqirisLinux 3 2a gcc 4 1 tar gz compiled under Debian etch 4 0 with gcc 4 1 The appropriate tar file should be copied to a local directory e g your home directory and then unpacked by using the following command tar xer AcogaprrSLrmHux os2a000XX targ The resulting directory AcqirisLinux contains an install script drv install and a graphical Demo program demo AcqirisDemo Before running the software you have to install the device driver into the running kernel User Manual Agilent Acqiris 12 bit Digitizers Page 12 of 48 2 3 1 Installing the Linux device driver The acqrsPCI device driver is a loadable kernel module It is provided both as source files and already compiled binary files for some kernel versions The compiled loadable kernel module is available for
52. izer and the driver have no way to know about such deviations The amplitude and threshold conditions for an External Reference are the same as for the External Clock If synchronization between several digitizers is required the reference signal should be applied to all of them 3 6 Internal Calibration The software drivers supplied include calibration functions for the timing gain and offset settings which can be executed upon user request The digitizers are never calibrated in an automatic way 1 e as a side effect of another operation This ensures programmers have full control of all calibrations performed through software in order to maintain proper event synchronization within automated test applications The digitizer includes a high precision voltage source and a 16 bit DAC used to determine the input voltage and offset calibration For accurate time and voltage measurements it is recommended to perform a calibration once the module has attained a stable operating temperature usually reached with a few minutes of digitizer operation after power on It should also be already set to the desired timebase settings Further calibration should not be necessary unless temperature variations occur A full internal calibration of a digitizer can be time consuming Therefore several other options are available They are documented in the Programmer s Reference Manual A program can always be started with the digitizer in an uncalibra
53. kefile has to point to the correct kernel header files The default is INCLUDEDIR usr src linux 2 4 This path usually is a link to the actual header files driver source To compile for a new kernel issue the following commands cd linuxdriverpci make clean to remove all o files in AcqirisLinux linuxdriverpci Make to generate a new kernel mode driver acqrsPCI o and also copy it to the directory AcqirisLinux lib module where the install script drv install can access it drv install rem to remove the previous installed kernel mode driver drv install add to install the new driver In the end the loadable kernel module should be present in the system s loadable kernel modules directory You can verify that it is present by running ls l lib modules uname r ACQIRIS acqrsPCI o 2 3 2 Loading the Linux device driver To install the device driver and the load script to the system you have to get super user privileges and execute the driver install script by typing Ca AGG 1 6 sts drv install add You can check that the driver is loaded properly with 1smod sbin lsmod grep acqrsPCI If Ismod does not report a module named acqrsPCI then the kernel module is not loaded into the kernel Read section 2 3 2 1 You can check that a device node has been created ls 1 dev acqrsPCI If the device node dev acqrsPCTI is not present on your system the Acqiris Software will not be able to access the device Read more in
54. lent Acqiris 12 bit Digitizers Page 44 of 48 Ts Appendix B XA001 Battery Backup for CompactPCI Digitizers Specification and Assembly Instructions BB1 Option SPECIFICATIONS Please refer to the user manual for more detailed information on the use of the battery backup Time to charge the battery lt 2 5 h digitizer powered Backup duration time without long memory option gt 120 h with long memory option gt 12 h Lifetime 7596 of battery capacity after 500 cycles CompactPCI digitizer Fl XA001 Battery Backup ATTENTION The CompactPCI digitizer must always been powered off before either introducing or removing the battery backup and care must be taken in order to avoid electrostatic discharges The following steps are necessary to install the battery backup XA001 into a CompactPCI digitizer 1 Position the battery backup between the guides A and B insuring that the orientation matches the figure below 2 Lift the two strips C and D in order to introduce the circuit board of the battery into the guides A and B 3 Push the battery in the direction of the card until it hits the stop blocks and ensure that the strips C and D are correctly and securely attached Proceed in the reverse order to remove the battery XA001 Battery Backup D User Manual Agilent Acqiris 12 bit Digitizers Page 45 of 48 8 Appendix C U1092A HVB XA100 BNC Input Overvoltage Protection Specifications a
55. ling rates available are Sampling Sampling Sampling Sampling Rate Rate Rate Rate MS s MS s MS s kS s The same pattern continues down to 100 S s 3 3 2 Acquisition Memory Data from the ADC is stored in on board acquisition memory The amount of memory in use for acquisition can be programmed and is selectable from 1 point to the full amount of acquisition memory available For technical reasons a certain memory overhead approximately 200 points is required for each waveform reducing the available memory by a small amount In order to simplify programming an interface function recommends the best sampling rate and the maximum possible number of data points taking into account the available memory the requested time window the number of segments in Sequence mode as well as the required memory overhead To ensure maximum sampling rate and high timing resolution we strongly recommend the use of long acquisition memories whenever possible For example the DC440 with 4 Mpoints of memory can record a signal over a 10 ms period with a sampling rate of 400 MS s 2 5 ns per point The fast sampling rate ensures that all high frequency signal components up to the full 100 MHz bandwidth of the digitizer are accurately recorded If the memory were reduced to just 20 Kpoints then the sampling rate would need to be reduced to just 2 MS s 20 000 10 ms to record the same 10 ms period All frequencies above 1 MHz would then be i
56. mber display area or alternatively the Acqiris Numeric Editor may be used In order to use the Acqiris Numeric Editor click on the green numeric editor icon at the left of the number display A numeric editor control will appear as shown The methods to change the values are 1 Increment or decrement any digit with the arrow buttons by pressing the increment or decrement button When the button is held down the digit will continue to increment or decrement automatically 2 Click on a digit and drag the mouse up or down to increase or decrease the value Trigger Delay Mouse sensitivity mmm Move pointer over digitto be changed AAA AAAAAAA Ln increase range 200 0000000 n 3 Type a new value with the keyboard for any highlighted digit The value is constrained to fall within its allowed range whenever the user attempts to enter a larger or smaller value Digits that are below the resolution or granularity cannot be modified A message is displayed in the numeric setting control window when the pointer is positioned over a digit that is below the allowed granularity and cannot be changed 4 2 4 Keyboard shortcuts Two shortcuts have been defined to simplify applying changes of a parameter to a group of channels When the mouse is over the control of a channel parameter s can be used to set the current value to all channels of all available instruments c can be used to set the current value to all channel
57. mode buttons in the Acquisition section of the control panel Available acquisition modes are Auto Normal Single and Stop Acquisition NORMAL 31 354 Acq s auTO NORMAL SINGLE STOP This Acquisition section of the control panel also indicates the number of waveforms acquired per second by the digitizer The use of each of the acquisition modes is described below In the discussion a valid trigger indicates a trigger signal meeting the trigger conditions at a time when the digitizer 1s armed and ready to acquire data Stop will stop the acquisition and hold the latest complete acquisition on the display Single mode is used in order to capture one event at the first valid trigger It freezes the acquisition in the digitizer s memory and on the display until the user requests another acquisition After an acquisition is taken in Single mode the digitizer will ignore subsequent trigger events until the Single button is pressed again or another acquisition mode is selected Pressing the single button re arms the trigger and captures one acquisition at the next valid trigger Normal mode is used to continuously acquire waveforms into memory for valid trigger events The display is updated with the new acquisitions in accordance with the Display Refresh Rate setting under the Options menu on the top line of the AcqirisLive Control window Acquisitions will happen for each valid trigger until either single or Stop 1s pressed If
58. multiple segments formatting with segments in columns is limited to 200 segments User Manual Agilent Acqiris 12 bit Digitizers Page 37 of 48 4 6 Calibrate The Calibrate item in the Options menu leads to a sub menu where a particular type of calibration can be invoked In order to use this item the acquisition must be stopped otherwise the Calibrate option is not selectable The possibilities are Calibrate instruments to perform a self calibration on the digitizers calibrating the gain offset trigger level and the timing Performing a calibration compensates for any drift in these properties typically due to component temperature variations Calibrate current combine configuration to perform a calibration only at the current configuration in each instrument Calibrate External Clock Timing to do a calibration of the internal TDC in the Continuous External Clock mode 4 7 External 10 MHz Reference and External Clock Either one of the External 10 MHz Reference or External Clock options can be selected in the Options Menu The external input threshold option available in the options menu must also be set appropriately The 10 MHz Reference can be activated at the I O B output The External Clock function is available in AcqirisLive only when using the control panel in Transient Recorder mode The input frequency should be keyed into the clock frequency selector outlined in red on the control panel in order fo
59. n December 2006 Please contact your nearest Agilent Service Center before returning any product for repair You can find information about technical and professional services product support and equipment repair and service on the Web see http www agilent com find service or http www agilent com and after selecting your country click on Contact Us The service center will ask for your name company phone number and address the model and serial numbers of the unit to be repaired and a brief description of the problem Before issuing a Service Order the service center may ask you to communicate with us by phone or eMail so that we can learn as much as needed about the problems observed If a unit returned under guarantee 1s found to be working normally and this procedure was not followed we reserve the right to charge you for the work done For your nearest customer support center please contact Acqiris Technical Support ACQIRIS SUPPORT agilent com or come visit our web site at http www agilent com find acqiris Alternatively contact Acqiris at 1 845 782 6544 in the USA 41 22 884 32 90 in Europe or 61 3 9210 2890 in the Asia Pacific region The Agilent Support Centers can also help redirect you for any questions concerning the installation and operation of your equipment 1 10 System Requirements Acqiris products need the following minimum PC System Requirements in order to obtain reasonable performance from your digitizer Pro
60. nality of the card and to serve as an easy to use and convenient program for capturing displaying and archiving captured data into the format of your choice binary or ASCII AcqirisLive is provided free with the purchase of any Acqiris digitizer We supply drivers on the CDROM for National Instruments LabWindows CVI LabVIEW Microsoft Visual C and Visual Basic We also provide some examples GetStarted applications as a guide or starting point for programmers developing their own applications to interface with the DC or DP series digitizer cards When you start AcqirisLive a display like that shown below appears 210 gt ET m Pele Instrument Setup Store Options Help View Zoom E 15600 crate 3 pos 10 Finder OF 0 Dspl s acqiris DP310 Ch1 Adv Input Voltage Scale Coupling 500 mV AC DC Offset Impedance ioo oov Gino img Adv Coupling O00 000V oc Delay Slope Y TED 00040 000s TN DA X Timebase 100 ns Div Memory MAX 50000 50 0 K samples e 3 1 00 segments max Sampling Interval Rate 2 3810 ns 420 00 MS s Acquisition STOPPED D Acq s AUTO NORMAL SINGLE STOP Trig Time 420 MS s 100 ns Div 17 01 54 Ready 18 35 08 Starting calibration 18 35 13 DP310 recalibrated all AcqirisLive displays two independent windows a control window and a display window The control window contains functions that allow you to manipulate the acquisition parameters
61. ncorrectly digitized and important signal characteristics may be distorted or even completely missed 3 3 3 Single and Sequence Acquisition Modes Digitizers acquire waveforms in association with triggers Each waveform is made of a series of measured voltage values sample points that are made by the ADC at a uniform clock rate To maximize sampling rates and utilize memory as efficiently as possible the digitizers include both Single and Sequential storage modes For both of these modes the data of all of the active channels is acquired synchronously all of the ADC s are acquiring data at the same time to within a small fraction of the maximum sampling rate The Single Acquisition mode is the normal operation of most digitizer products In this mode an acquisition consists of a waveform recorded with a single trigger The user selects the sampling rate and acquisition memory size and set the number of segments to 1 default value The Sequence Acquisition mode allows the capture and storage of consecutive single waveforms Sequence Acquisition mode is useful as it can optimize the digitizer s sampling rate and memory requirements for applications where only portions of the signal being analyzed are important The mode is extremely useful in almost all impulse response type applications RADAR SONAR LIDAR Time of Flight Ultrasonics Medical and Biomedical Research etc In Sequence Acquisition mode the acquisition memory is divided i
62. nd with the PC running under Windows 2000 NT or XP will not need the GeoMapper Users who do not need GeoMapper do not need to read this chapter any further 5 2 When should the GeoMapper Application be used The application needs to be used whenever the bus or slot configuration of the system changes in a fundamental way The most obvious trouble symptom is that an expected multi Instrument was not found Alternatively the driver can issue error messages that the AcqirisLive application and other programs will see Among them are Modules are not contiguous in AS bus combination ACOIRIS ERROR MODULES NOT CONTIGUOUS AS bus Candidate Modules not on same bus ACQIRIS ERROR MODULES NOT ON SAME BUS AcqGeo map file is invalid or corrupted ACQIRIS ERROR INVALID GEOMAP FILE In all of these cases the GeoMapper application should be run to ensure that the map file is up to date If desired the GeoMapper application will generate a default configuration in which it allows the driver to make all of the choices This is done by specifying None Disable GeoMap as the desired configuration in Stepl Crate count of the application 5 3 How to run GeoMapper After software installation you will find GeoMapper in the AcqirisApp directory of the installation directory After being started the program will learn about the Acqiris devices present and then show a screen like the one below E Acqiris GeoMap Wizard E A x Step 1 Crate count Step
63. nd User Instructions The XA100 Acqiris option contain two elements 3dB BNC Attenuator 90V BNC Spark Gap The XA100 overvoltage protection kit allows the digitizers with 50 Ohm only input without high impedance input to withstand a high voltage surge of up to 5 kV XA100 SPECIFICATIONS Frequency range DC to 1GHz Input impedance 50 Ohm Attenuation 3 dB VSWR DC to 1GHz lt 1 25 Impulse discharge current 8 20 us pulse 10 kA Weight 60 g Length 85 mm ATTENTION BOTH the 90V spark gap and the 3dB attenuator MUST be used in order to absorb very high current In order to limit the input current the attenuator MUST be inserted between the spark gap and the input of the module as shown in the figure below 3dB BNC Attenuator M SS b zn 90V BNC Spark Gap ST y E uw y EN 5 9292 Digitizer 90V BNC Spark Gap f _S Input Channel A 3dB BNC Attenuator J i Input Channel B User Manual Agilent Acqiris 12 bit Digitizers Page 46 of 48 9 Appendix D U1091A X01 XP100 Fan Unit for the DP Digitizer Family Specifications and User Instructions XP1 Option SPECIFICATIONS Airflow 8 m3 h typical speed 6000 rpm maximal noise 35 dB A Nominal Voltage 5 VDC Power input 0 8 W With electronic protection against reverse polarity impedance protected against blocking and overloading Operating temperature 0 C to 70 C Life expectancy at 25 C 4500
64. ngs of the current channel and the timebase and trigger of the correspondent digitizer are then indicated A unique name is given to each channel installed on the PCI bus The current channel is indicated by a dark highlight over the name Settings changed on the main control panel will only affect the active channel Always verify proper acquisition setting for each channel prior to collecting data There is a small rectangular indicator button to the left of each channel name in the channel list If this indicator 1s filled in the channel waveform is active the channel is turned on and displayed in the display window Clicking on this indicator once turns it transparent This deactivates the reading of the data from the channel and clears the waveform display Clicking once again on the indicator turns the channel back on and the indicator 1s filled in After making such changes the channel data will not be displayed until after the next acquisition The image at the left shows a channel list with two active channels in the system All are turned on and displayed in the display window as indicated by the orange indicators at the left The DP310 Chl is the currently selected channel The channel list image at the right shows the same system The DP110 Chl indicator is transparent and therefore this channel is turned off and not displayed As an alternative to controlling the channels to be displayed from the control panel you can also control
65. nput voltage range that will allow the signal to be recorded using as much dynamic range of the digitizer as possible The Variable Offset is programmable in the range of 1 V for FS 1 V increasing to FS Voltage for less sensitive settings The raw 12 bit ADC data values are read as 16 bit integers in the range 32768 32752 with steps of 16 LSB s between allowed values The first and last values are reserved for underflow and overflow respectively The midpoint value 0 of the range corresponds to the negative of the offset voltage Thus the Full Scale Range FSR goes from Offset Voltage FS 2 to Offset Voltage FS 2 Signals going outside of the FSR will be clipped and data values for the clipped portion of a signal should be regarded as erroneous 3 2 6 Vertical Resolution The digitizers described in this manual use an ADC system with 12 bits of vertical resolution 4096 levels The dynamic range of the ADC covers the Full Scale Range FSR of the Input Voltage setting For example if the FS Input Voltage is set to 1 V then the ADC resolution is equivalent to 0 2441 mV However the corresponding LSB gain is 1 16 of this value To obtain the best dynamic range from the ADC care should be taken to ensure that the input signal varies over more than 50 of the Input Voltage FSR setting As a function of sampling rate the two ADC s of each channel can be used to sample the signal simultaneously and their results will be av
66. ns to take to avoid electrical mechanical or operational damages NOTE Denotes a note which alerts you to important information Italic text denotes a warning caution or note Bold Italic text is used to emphasize an important point in the text or a note mono text is used for sections of code programming examples and operating system commands User Manual Agilent Acqiris 12 bit Digitizers Page 5 of 48 1 4 Model Names Agilent Technologies Inc acquired Acqiris SA and its product lines in December 2006 Use the tables below to cross reference the legacy model name and new Agilent numbers Agilent Acgqiris Model Model Number Name U1066A DC436 U1066A DC438 U1066A DC440 U1070A DP306 U1070A DP308 U1070A DP310 1 5 Disclaimer and Safety The DP Series 12 bit PCI digitizer cards have been designed to operate in a standard PCI slot found inside most personal computers The DC Series 12 bit CompactPCI PXI digitizers have been designed to operate inside a CompactPCI PXI crate The crate provides the modules with all needed power Agilent Technologies does not recommend operation of their DC modules outside of a CompactPCI PXI crate CAUTION Do not exceed the maximum input voltage rating The maximum input voltage for the BNC channel inputs is 10 V The maximum input for the SMA channel inputs is 15 V dc 2 V rms ac and the trigger BNC is 5 V dc ac 1 6 Warning Regarding Medical Use The Digitizer cards are not de
67. nto a pre selected number of segments Waveforms are stored in successive memory segments as they arrive Each waveform requires its own individual trigger The memory can be divided into any number of segments between 2 and 100 up to 8000 segments with options M4M or M8M In Sequence Acquisition mode the user needs to specify the sampling rate the total acquisition memory and the number of segments Note that the Single Acquisition mode is just a special case of the Sequence Acquisition mode with the number of segments set to 1 Sequence acquisition enables successive events which can occur within a very short time to be captured and stored without loss A crucial feature of Sequence Acquisition mode is that it has a very fast trigger rearm time A fast trigger rearm helps produce very low dead time between the segments of a sequence acquisition The dead time User Manual Agilent Acqiris 12 bit Digitizers Page 22 of 48 is the period after the end of an event when the card cannot digitize data for a new trigger event To complement this mode of operation the digitizer can also measure and store the arrival time of each trigger using the information from the on board TTI Trigger Time Interpolator Readout of the individual trigger time stamps makes it possible to determine the time from one trigger to any other trigger in the sequential acquisition The TTI resolution sets the resolution of the trigger time stamps see section 3 3 4 Timing
68. of the card In order to display an acquired waveform connect a signal to the input and then select the Auto acquisition mode at the bottom of the control panel A waveform should appear in the display User Manual Agilent Acqiris 12 bit Digitizers Page 29 of 48 Other controls in the control panel allow you to select the optimal acquisition settings for your particular signal Each of the other control panel functions will be discussed in detail in the following Control Panel Functions section Here is a sample result Ini xi NETTES E ziEpxd Instrument Setup Store Options Help View Zoom E 15600 crate 3 pos 10 Fiier i Tos 19 019 Dspl s es DP310 Ch1 Ad Input Voltage Scale Coupling BH my AC DC Input Voltage Offset Impedance S f2 1M9 i 0 0000 nov Ady Coupling ooo 000V c ov Delay E 0 00E 0 000s Timebase 8H B Memory MAX 50000 50 0 K samples E 1 1 00 segments max Sampling Interval Rate 2 3810 ns 420 00 MS s Acquisition NORMAL 994 494 Acq s 420 MS s NORMAL SINGLE 17 01 54 Ready 18 35 08 Starting calibration 18 35 13 DP310 recalibrated al 4 2 Control Panel and Functions DSO TR 4 2 1 Control Panel Mode INI In AeqirisLive there are two control panel modes available Oscilloscope Mode and Transient ri n Recorder Mode The choice of mode is entirely determined by the preference of the user Both modes provide the same set of functional c
69. ould appears as shown here Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for D Acqiis PCI Instrument N NOTE In some systems an application program such as AcqirisLive will not yet work correctly at this point One additional boot cycle may be needed if this is the first time that a hardware board is being installed User Manual Agilent Acqiris 12 bit Digitizers Page 16 of 48 2 6 LabVIEW RT During program development you can choose whether you use LabVIEW or LabVIEW RT compatible libraries by switching the version present in National Instruments LabVIEW m n instr lib This swap can be facilitated by using the Install VI library for LabVIEW or LabVIEW Real Time shortcut available in the Shortcut folder under Start Programs There is only one Acqiris Driver It supports all Acqiris Instruments The instructions below concern LabVIEW RT as used in NI PXI processors The Aq RT inf and AqRT 4 ini files must be uploaded to the target To do this e start the MAX application e rightclick on the target e select file transfer e selectthe Aq RT inf file on your host machine and upload To Remote to the LabVIEW RT working directory NI RT system on the target e select the Aq RT ini file on your host machine and upload To Remote to the LabVIEW RT working directory NI RT system giving it the name AqDrv4 ini For Acqiris modules which need FPGA
70. r the proper timebase to be displayed on the waveform display window The time window displayed can be manipulated by allocating more or less memory to the acquisition The External 10 MHz Reference in AcgirisLive is designed to work either in Oscilloscope Mode or in Transient Recorder Mode The timebase and sample rate for waveform capture is fully selectable when using the external reference just as it is when using the digitizer s own internal reference clock 4 8 Additional Waveform Information The Options menu also includes possibilities to obtain additional information about the waveform In both cases described below the display will be updated after each acquisition The Show Segment Timestamps option shows a display like the one below loxi pcz oce Ll It gives you the information needed to better understand the trigger times of the individual segments of an acquisition By definition the first trigger of an acquisition occurs at tj 0 0 There are two columns for each digitizer For the n th row the first column contains the difference t t and the second column contains t The top line contains the average value of the t in the left column and the standard deviation of the t in the right one The times are in ps Average StdDev The Show Parameters option activates a display of pulse parameters for each active channel Inactive channels will have parameter values of 0 0 The parameters
71. rate This is shown below E Acgiris GeoMap Wizard B i 2 x Step 1 Crate court Step 2 Bus location Step 3 Crate size Step 4 Module locations How many slots do you have in each crate Select corect nbr include system and empty slots Crate 1 has 21 Slots Nent gt gt The 4 step consists of arranging the modules of each crate into the correct order The menu shown below is one in which all of this work has been done for the modules of a fully populated CC121 Selecting a position will cause a module to have its red LED turned on Then the Up and Down buttons will allow you to move the module in question to the desired Position in crate User Manual Agilent Acqiris 12 bit Digitizers Page 42 of 48 E Acgiris GeoMap Wizard 5 b b 5 b 6 b 5 5 5 h 5 5 5 4 4 4 4 4 4 hoo IA inom oo lt epstem slots The final step is to actuate the Save button so that the final configuration will be memorized and made available to the driver The GeoMapper application will always work with the standard AqGeo map file If you need to have several such files corresponding to different configurations it is up to you to either rename the files or transfer them to other directories in an appropriate manner User Manual Agilent Acgiris 12 bit Digitizers Page 43 of 48 6 Appendix A U1056A AS bus for CompactPCI PXI Digitizers Specification and User Instructions for A01 A02 A03 A0
72. rd startup m file to incorporate the Acqiris adaptor n the Installation Folder window you will give the name of the root directory of the Acqiris software installation If User Manuals 30 MB and Firmware 40 MB are loaded more space than indicated here will be required on the drive For the case of a Tornado 2 2 installation the folder name should not contain any spaces AcgirsLive needs the LabWindows CVI 7 0 Run Time Engine to run If Setup has detected that a LabWindows CVI Run Time Engine is already installed on your system it will ask you if you would like to install it locally for AcqirisLive anyway If you are not sure about the version of the CVI Run Time Engine on your system it is recommended to install it locally The Installation Summary window will be shown to allow you to check what you have asked for At this point it is not too late to go back and make changes The actual installation will only be started after clicking on Install in the next window Please read the IMPORTANT Information window text It could help you avoid serious problems Registration of your installation will help Agilent provide you with better support You will also be notified of updates and upgrades All information submitted will be treated in accordance with Agilent s privacy policy Setup will prepare a registration e mail in your e mail client application upon termination of the setup procedure You can then decide whether or not you w
73. rs Page I1 of 48 2 2 3 Installation Before installing the Acqiris hardware you should complete the following steps to install the software for Windows 2000 XP NOTE You will need administrator privileges to complete the software installation under Windows 2000 XP 1 Insert the Acqiris Software CD into the CD ROM drive of your computer If the Autorun program does not start automatically Autoplay disabled you can start it manually or navigate to the AcgirisSoftware Windows folder in order to display the files included 2 Choose Install AcqirisSoftware for Windows 2000 XP 2003 Server or run Setup exe from the AcgirisSoftware Windows folder After several seconds for initialization the first of many screens will appear Please note the following points tis good practice to remove any previously installed version o0f Acqiris software If the program finds that there is still Acqiris software installed on your machine a warning panel will appear In the Select Install Type window selecting Custom installation will let you select individual packages for loading The space indicated for LabVIEW Firmware and UserManual packages is incorrect The correct values are 7 MB 40 MB and 30 MB respectively A full installation requires just under 150 MB of disk If MATLAB is installed on your machine you will be asked to point the installer to the MATLAB root directory You should do this if you want the installer to modify the standa
74. s at a time that corresponds to the post trigger delay i e the trigger point is before the acquired waveform The digitizer hardware accepts pre and post trigger adjustments in increments of 16 samples By definition post trigger settings are a positive number and pre trigger settings are a negative number Thus it is only natural that the software drivers provided treat pre and post trigger delays as a single parameter in seconds that can vary between nbrSamples samplingInterval 100 pre trigger and maxPostTrigSamples samplingInterval max post trigger Since the Acqiris software drivers provide very accurate trigger position information upon waveform readout the accepted resolution of the user requested pre post trigger delay is much better than 16 samples For more details refer to the Programmer s Guide 3 4 6 TV Trigger The TV trigger mode can be used for a composite video signal with negative going synch positive modulation on the External Trigger Input The TV trigger mode implements line number and odd even field selection for 625 50 2 1 PAL SECAM B G L Standards and 525 60 2 1 NTSC M Standard signals The TV trigger is AC coupled and a minimum synch pulse amplitude of 0 3 V pk pk is required 3 4 7 Trigger Status The front panel includes a tri color LED indicator to show the status of the trigger When the LED is green it indicates the trigger is armed and waiting for a valid trigger to occur Red indicates th
75. s of the current instrument Other shortcuts are Ctrl S as a synonym for Save Setup Ctrl R as a synonym for Recall Setup Ctrl C as a synonym for Calibrate all active instruments Ctrl E functions as a toggle between Internal Clock and External Clock operation User Manual Agilent Acqiris 12 bit Digitizers Page 32 of 48 4 2 5 Input Voltage Scale Offset and Coupling Settings for input voltage scale offset coupling and impedance Rahen pum are available in the portion of the control panel shown to the right Input Vallage Seale The selected channel is shown on the upper section of the display Only this channel will be affected by changes in any settings on Bo i we the control panel The input voltage scale is set by one of three possible methods Coupling AC CDC Impedance Input Voltage Offset gooo o oo 5052 1 Clicking on the white numeric display of the voltage scale will show a pop up list Select the desired gain setting with the mouse pointer 2 Clicking on the Decrement Increment icons will step the voltage scale up or down to the next level for each click of the mouse 3 Clicking Max Min will toggle to the least sensitive gain setting or to the most sensitive gain setting NOTE Coupling 1s used to select which signal input connector is to be used The input Coupling can be set for AC or DC The selected setting is shown as an actuated indic
76. section 2 3 2 2 The drv install script has the following additional functionality drv install rem to remove the driver and load script drv install res to restart the driver 2 3 2 1 Loading the module into the kernel If you are running a Linux distribution that does not use the standard paths for the load scripts you have to load the device driver manually The kernel module should be present in the kernel modules directory Check with the following command ls 1 lib modules uname r extra acqrsPCI ko First update the kernel modules dependencies sbin depmod a Then load the kernel module sbin modprobe v lib modules S uname r extra acqrsPCI ko The acqrsPCI kernel module should now be loaded correctly Check with Ismod You can add the command above to your etc rc local file It is run at system startup and will load the acqrsPCI kernel module automatically when your computer is restarted User Manual Agilent Acqiris 12 bit Digitizers Page 14 of 48 2 3 2 2 Creating the device driver node For systems using udev the dynamic dev hierarchy or running kernels above 2 6 17 the device driver node may not be created automatically You can do it with mknod running the following command sbin mknod m 666 dev acqrsPCI c 124 0 You can check that the device node has been created ls 1 dev acqrsPCI You can add the mknod command to your etc rc local file It is run at system startup and will create the dev acqrs
77. signed with components and testing procedures that would ensure a level of reliability suitable for use in treatment and diagnosis of humans Applications of these cards involving medical or clinical treatment can create a potential for accidental injury caused by product failure or by errors on the part of the user These cards are not intended to be a substitute for any form of established process or equipment used to monitor or safeguard human health and safety in medical treatment WARNING The modules discussed in this manual have not been designed for making direct measurements on the human body Users who connect an Acqiris module to a human body do so at their own risk 1 7 Packaging and Handling Your Digitizer is shipped with the following components e Acompact disc in an Agilent Technologies paper CD envelope that includes o 10 product User Manuals in electronic form 8 bit Digitizers 10 bit Digitizers 12 bit Digitizers Averagers Analyzers Signal Analyzers Streamer Analyzers Time to Digital Converters 3 5 and 8 slot CompactPCI Crates and the 21 slot CompactPCI Crate o Programmer s Guide and 1 Programmer s Reference Manual o device drivers with sample software for different operating systems environments and languages o the AeqirisAnalyzers application a demonstration program for the AC SC Analyzer products o the AcqirisLive application a demonstration program for our digitizer and averager products o the DemoSS
78. st turn off the channels of slower digitizers in order to view the highest sampling rates of the faster digitizers 4 2 10 Segmented Memory Segmented memory enables the sequential acquisition mode having less than 1 us dead time between segments at the maximum sampling rate This feature is particularly useful when capturing impulse response type waveforms in a variety of applications Segmented memory is available in all acquisition modes However it is generally used in either Normal or Single mode Waveform display occurs only after all segments are filled Segments can be displayed sequentially on the display or they can be overlaid on top of each other To select an overlaid display select the item Overlay Segments under the Options menu Segmented data can be archived to any storage device on the computer in a similar way to non segmented acquisitions If the acquisition needs to be stopped before all segments are filled press the Stop button In order to set up the sequential acquisition mode simply select more than 1 segment on the segment sl selection control under the Memory section of the control window and start the acquisition 4 2 11 Display Features Zoom and Persistence A waveform zoom feature is available under the View menu of the display window The screen image below shows the normal display and the zoom window that appears when zoom is selected The zoom scale and center position are modified using the horizontal
79. t Digitizers Page 27 of 48 Safety Complies with EN61010 1 EMC Immunity Complies with EN61326 1 Industrial Environment EMC Emissions Complies with EN61326 1 Class A for radiated emissions Required Airflow 2 m s in situ User Manual Agilent Acqiris 12 bit Digitizers Page 26 of 48 4 Running the AcqirisLive Application AcdqirisLive is an application to control and demonstrate the capabilities of Acqiris digitizers on a single machine AcqirisMAQS is a more advanced application offering many interesting possibilities for the control of acquisition systems in a single or multi machine environment Ask your sales representative or Agilent Acqiris Support for more information 4 1 Getting Started with AcqirisLive Once the software and hardware installation described in Section 2 of this manual is complete you will find AcqirisLive in the start menu of your computer Start AcqirisLive from the menu An initial AcqirisLive load screen will appear followed by a panel of controls and a waveform display window During startup AcqirisLive searches for all Acqiris digitizers on the PCI bus If no digitizers are found on the PCI bus AcqirisLive will display an error message indicating that no digitizers were found and the program will continue in simulation mode If this is not wanted turn off the computer install and turn ON the hardware on the PCI bus and then restart the computer AcqirisLive is intended to verify the functio
80. t as normal waste Separate collection is appropriate and may be required by law User Manual Agilent Acqiris 12 bit Digitizers Page 9 of 48 A 2 Installation This chapter describes how to install the Acqiris hardware and software for Windows 2000 XP National Instruments LabVIEW RT Linux or Wind River VxWorks NOTE For a first time installation we strongly recommend installing the software before inserting the hardware into the PC 2 1 U1091AK02 ICA14 Installation NOTE If you are going to install an IC414 interface for the first time and are running Windows 2000 XP you should follow the procedure below before installing the Acqiris hardware 2 1 1 IC414 Hardware installation hints The PCI 8570 PXI 8570 User s Manual Rev 1 00 section 2 5 gives Hardware Installation instructions CAUTION Turn off the power of the PC the PC may have to be unplugged to ensure that the PCI bus has no power available Please ignore the PCI 8570 instruction to leave the power cord plugged in Ground the chassis differently CAUTION Touch the antistatic package to a grounded object before removing the card from the package Electrostatic discharge can damage the card The standard cable pair provided each have a red connector on one end and a black connector on the other Therefore the correct connection can be made by plugging the Red connector into the LORx socket and the Black connector into the LOTx socket on the PXI module and the other Re
81. ted state and data taken can be used for many kinds of testing However as soon as good data respecting the specifications of the instrument is required a calibration of at least the current acquisition state is needed The full internal calibration has the advantage that it generates the calibration constants needed for any possible configuration of the instrument its disadvantage is the time taken If a more selective calibration is done it will allow the generation of good data in the current acquisition state This calibration will remain useable whenever that acquisition state is used again for as long as the temperature of the instrument does not change significantly A fast calibration of a channel in a configuration can be done in around a second Many applications can save time by only performing calibration for the configurations that will actually be used Calibration can usually be performed with signals present at the channel external and clock inputs However if the calibration is found to be unreliable as shown by a calibration failure status it may be necessary to remove such signals 3 7 AS bus The digitizers may be used in applications that require many data acquisition channels In such cases it is possible to use more than one digitizer in a standard CompactPCI PXI crate Each DC Series digitizer includes AS bus a proprietary high bandwidth auto synchronous bus system that allows multiple digitizers to work together synchronously
82. ted triggers such as those of the AUTO mode of AcqirisLive or through the use of the function AcqrsDI forceTrigger However AcqrsD1 forceTriggerEx does generate the signal Trigger Output Block diagram The output swing is 1 6 V 0 8 V when unloaded and 0 8 V when terminated on 50 Signal 1 6V swing The rise and fall times are 2 5 ns typical Ov centered The offset can be adjusted by software control in the range 2 5 V 42 5 V unloaded or 1 25 V 1 25 V into 50 Q Offset 2 5 V The maximum output current capability is 15 mA As the output is retro terminated it is possible to drive a 50 Q line unterminated HiZ without loss of performance Trigger Out For a TTL compatible signal set the offset to 1 0 V and the swing at destination will be 0 2 to 1 8 V For an ECL compatible signal terminated on 50 Q to 1 2 V set the offset to 1 2 V and the output will be in the range 0 8 V 1 6 VJ 1 18V GND Alternatively to reduce the current drawn from the digitizer the terminations shown here can be used User Manual Agilent Acqiris 12 bit Digitizers Page 26 of 48 3 10 Electrical Environmental and Physical Specifications 3 10 1 Electrical EN Max Power Consumption W Current Requirements A with Memory option Model Default with Memory 12 V 5 V 3 3 V 12 V option pewo 23 25 os s eD o nca 3 25 os s 1602 o2 DCA36 1602 2 o DP
83. terial strength 4 Seal the shipping container securely with strong nylon adhesive tape 5 Mark the shipping container FRAGILE HANDLE WITH CARE to help ensure careful handling 6 Use the address obtained from your Agilent Technologies Service Center 7 Retain copies of all shipping papers CAUTION Damage can result if the original packaging materials are not used Packaging materials should be anti static and cushion the instrument on all sides NEVER USE STYRENE PELLETS IN ANY SHAPE AS PACKAGING MATERIALS They do not adequately cushion the instrument or prevent it from moving in the shipping container Styrene pellets can also cause equipment damage by generating static electricity or by lodging in fan motors 1 12 Maintenance The cards do not require any maintenance There are no user serviceable parts inside A periodic calibration can be obtained on request User Manual Agilent Acqiris 12 bit Digitizers Page 6 of 48 1 13 Cleaning Cleaning procedures consist only of exterior cleaning Clean the exterior surfaces of the module with a dry lint free cloth or a soft bristle brush If any dirt remains wipe with a cloth moistened in a mild soap solution Remove any soap residue by wiping with a cloth moistened with clear water Do not use abrasive compounds on any parts 1 14 Disposal and Recycling Electronic equipment should be properly disposed of Acqiris digitizers and their accessories must not be thrown ou
84. th is 400 MHz The digitizer will trigger on signals with a peak peak amplitude gt 10 FS from DC to their bandwidth limit 3 4 4 Edge Trigger Slope The trigger slope defines which one of the two possible transitions will be used to initiate the trigger when it passes through the specified trigger level Positive slope indicates that the signal 1s transitioning from a lower voltage to a higher voltage Negative slope indicates the signal is transitioning from a higher voltage to a lower voltage 3 4 5 Pre and Post Trigger Delay To increase trigger flexibility a pre or post trigger delay can be applied to the trigger position The amount of pre trigger delay can be adjusted between 0 and 100 of the acquisition time window 1 e sampling interval x number of samples whereas the post trigger delay can be adjusted between 0 and 100 million samples Pre or post trigger delays are just different aspects of the same trigger positioning parameter e The condition of 100 pre trigger indicates that all data points are acquired prior to the trigger 1 e the trigger point is at the end of the acquired waveform e The condition of 0 pre trigger which is identical to a post trigger of 0 indicates that all data points are acquired immediately after the trigger 1 e the trigger point is at the beginning of the acquired waveform e The condition of a non zero post trigger delay indicates that the data points are acquired after the trigger occur
85. them by selecting the desired channels from the list of channel gains shown at the right hand side of the display window User Manual Agilent Acqiris 12 bit Digitizers Page 31 of 48 O x Help Instrument C Instrument Setup Store Options DP310 Ch1 Ady Input Voltage Scale Coupling Impedance 5022 Ady Input Voltage Offset iioo 0oy Trigger Edge class Source DP310 Ch1 v Level 1 i073 n non 0 00 Coupling oc Book 2 Timebase H 100 ns Div Memory MAX 50000 50 0 K samples afi 1 00 segments max Sampling Delay 0 00 s Interval Hate l 2 3010 ns l 420 00 MSs Acquisition STOPPED AUTO NORMAL SINGLE STOF Zl 10 23 33 Ready 10 23 45 Starting calibration 10 23 50 DP 310 recalibrated ail lus 15600 crate 3 pos 10 Pressing the Finder button at the top of the control panel will identify the module associated with the current channel When the finder button is depressed the LED on the front panel lights up yellow on the digitizer module with the current channel 4 2 3 Numeric Editor The numeric editor is shown in the control window at Lire AO0 00E 4 locations where numeric values are set The Acgiris Numeric Editor enables easy input of numeric values particularly those ranging over many decades The numeric value can be changed in multiple ways A number can be typed directly into the white nu
86. ting menu looks as shown User Manual Agilent Acqiris 12 bit Digitizers Page 10 of 48 Driver 5igning ptions During hardware installation Windows might detect software that has not passed Windows Lago testing to verify its compatibility with Windows Tell me why this testing is important What action da you want Windows to take Ignore Install the software anyway and don t ask For my approval Q Warn Prompt me each time En choose an action CO Block Never install unsigned driver software Administrator option Make this action the system default The PCI 8570 PXI 8570 User s Manual Rev 1 00 section 2 4 contains the software installation instructions These should be executed before allowing the hardware installation process to look for the driver If you have an AdLink CD Version 2004A4 or later you can use it if not you should download the latest driver from the WEB site http www adlinktech com You can then continue with the Hardware Installation A reboot will then be necessary At this point the Stargen Fabric PCI Adapter and the Stargen Aruba Fabric to PCI Bridge should appear correctly installed under System Devices in the Device Manager NOTE If you have an AdLink CD Version 2005A3 or later you can find 8570install exe in the folder X Driver Installation PXI Platform PXI Extension PCI PXI 8570 Wnt2kxp and the starfabl inf file in the folder X Driver Installation PXI Platform P XI Extension PCI PXI 8570
87. tion against reverse polarity impedance protected against blocking and overloading Operating temperature 0 C to 70 C Life expectancy at 25 C 50000 hours Safety approvals CE VDE UL and CSA Materials Box of stainless steel aluminium and fan of fiberglass reinforced plastic PBT housing PA impeller HOW TO INSTALL REMOVE THE FAN ON A DIGITIZER 1 Remove the digitizer from the PC prior to installing or removing the fan unit 2 Twist the fan s cable a few times in order for the 2 wires to stay together 3 Introduce the cable between the spacers A and B at the back of the digitizer 4 Push the fan unit into the back of the digitizer so that the two springs lock into place 5 Insure that the two springs are safely attached behind the two spacers and that the fan s box is in contact with the digitizer cover 6 Connect the fan s cable The position of the power connector can vary between different digitizer models 7 To remove the fan unit first unplug its power cable and then press on both fan springs and pull it away from the digitizer HOW TO INSTALL REMOVE THE DIGITIZER IN A PCI SLOT OF APC 1 Install the fan on the digitizer as described above 2 Release the three screws R from the adjustable retainer and move the retainer against the fans 3 Introduce the digitizer into the PCI slot and tighten the front panel screw 4 Push the retainer into the PCI slot guide and tighten the three screws R The d
88. trator privileges after the first boot following the hardware installation the Plug amp Play system must have the appropriate privileges to be able to complete your hardware installation successfully After a successful hardware installation you will be able to use your Acqiris digitizer s with normal privileges At the first boot following the hardware installation Windows will detect the new hardware and will install the devices automatically The following image will appear Acqirs PC Instrument Installing N NOTE In some systems an application program such as AcqirisLive will not yet work correctly at this point One additional boot cycle may be needed if this is the first time that a hardware board is being installed 2 5 2 Windows XP Under Windows XP you must login with administrator privileges after the first boot following the hardware installation the Plug amp Play system must have the appropriate privileges to be able to complete your hardware installation successfully After a successful hardware installation you will be able to use your Acqiris digitizer s with normal privileges If you login with administrator privileges after the first boot following the hardware installation Windows will detect the new hardware and start the Found New Hardware Wizard after a few seconds There is no need to use Windows Update to search for the software You can Install the software automatically The final screen sh
89. veforms from all of the Autostore Setia X active channels into files Configuration of Destination folder Autostore is achieved by selecting the Autostore Ee aeanclivet lala item under the Store menu Autostore brings up the dialog box shown here Three formats are available i saaaasas E TM i ssususnauauuan i T saasasas i nsnnnonnnnnnnnn E for stored waveforms Binary Raw ADC values UMOE OF waverorms to Store iw and Amplitude values in Volts The destination Mag total samples memory MB afso folder can be selected or created on any system drive using the Browse button Waveforms will be stored in a new folder under the destination folder The new folder will be named at AcqirisRun_ date _ time Each waveform willbe Binar format BAM 24 4 MB stored in a file with a name channel C Raw ADC values identifier i suffix where i goes from 1 to N Amplitudes V Total storage 24 5 MB and the suffix indicates the data type If the data is stored in Binary form the suffix will be data and PO Lucmeris m CObubuts an additional ASCII format awh file is written m which contains necessary details about each of the v white files at end Show waveforms other files Otherwise the suffix will be awd gk The number of generations of waveforms to be stored with this function is selectable from 1 to N N is a maximum number dependent on the number of samples taken in each waveform There is also a user selectabl
90. will be calculated in a model in which the distribution of measured voltages has two distinct peaks If this condition is not satisfied the results will be unreliable 4 9 Display Features Display features in the Options menu include items for e turning the waveform display off by de selecting Display Waveforms e modifying the display refresh rate e overlaying segments of a sequence e connecting displayed data points e calculating and displaying waveform parameters e displaying the internal temperature of the currently selected module e displaying a list of segment timestamps User Manual Agilent Acqiris 12 bit Digitizers Page 36 of 48 4 10 Command Line Switches When starting the AcqirisLive application the executable s name in the command line can be followed by one or more switches to change the running conditions Syntax The syntax of the command line is the following pathNAcqirisLive exe a cl d h i 1 m 7n p 7s t v 7x Available Switches List of available switches a start in Averager mode C no initial calibration d use DMA for data transfers default h high priority process default i use acquisition interrupts low priority process m medium priority process n no DMA for data transfers p Use acquisition polling r start in Transient Recorder control panel mode S simulation mode t temperature update off V show acquisition state X disable automatic mult
91. xceeds the requirements specified Chapter 2 INSTALLATION covers all elements of installation and performance verification Before attempting to use your Acqiris product for actual measurements we strongly recommend that you read all sections of this chapter Chapter 3 PRODUCT DESCRIPTION provides a full description of all the functional elements of the digitizer Chapter 4 RUNNING THE ACOIRISLIVE APPLICATION describes the operation of AcqirisLive 3 2 an application that enables basic operation of Acqiris digitizers in a Windows 2000 XP environment Note AcqirisMA QS is an alternate software application offering many interesting possibilities for the control of acquisition systems in a single or multi machine environment Ask your sales representative or Agilent for more information Chapter 5 RUNNING THE GEOMAPPER APPLICATION describes the purpose and operation of the GeoMapper application which is needed for some AS bus Multi instrument systems For information necessary for writing your own software to control Acqiris products you should refer to the Programmer s Guide and the Programmer s Reference Manual 1 3 Conventions Used in This Manual The following conventions are used in this manual This icon to the left of text warns that an important point must be observed WARNING Denotes a warning which advises you of precautions to take to avoid being electrically shocked CAUTION Denotes a caution which advises you of precautio
92. zed the sample rate will decrease with increasing capture times In this mode many sampling rate or interval choices are possible Moreover if the Adv Sampling option is activated the full range of potential choices becomes available User Manual Agilent Acqiris 12 bit Digitizers Page 34 of 48 4 2 9 Using digitizers of different models simultaneously AcqirisLive features a single timebase i e the set of acquisition parameters pertaining to the time axis of the waveform such as the sampling rate and the number of samples It is therefore not possible to specify different timebase settings for different digitizers However it 1s possible to run each digitizer at its maximum available sampling rate performance in the following way e Select the Oscilloscope Mode e In the channels list select a channel from the fastest digitizer that will make that digitizer the current digitizer e Make sure the maximum number of samples MAX samples in Memory panel is large enough e Select the desired time per division setting timebase panel the fastest sampling rate for the current digitizer compatible with the maximum number of samples will be selected and applied to all digitizers in the system Any digitizer not capable to satisfy that sampling rate will run at its closest setting Finally note that the sampling rate menu visible in Transient Recorder Mode contains the sampling rate capability of all digitizers currently in use You mu