Home

S811 Soft Starters

image

Contents

1. AIl IT soft starters are furnished with 24V DC coils and control power supplies For 24V DC separate control use Mod Code C35 and change the 8th digit to Q i e ECS95S1EAF becomes ECS95S1QAF C35 Standard duty horsepower ratings are for 300 ramp current 30 seconds ramp time and 3 starts per hour Consult Eaton for other ratings Based on 1 0 Service Factor For 1 15 consult Eaton Consult Eaton Dimensions Table 28 Minimum Enclosure Box Numbers Rating SSRV Non Combination Combination combination with Fuses with HMCP Box No Box No Box No 8 27A 752 6A B10 A1 37A 801 S811 7A B1 A1 50A S752 6A Cc A1 66A 801 S811_ 7A C A1 105A S801 S811 7A cD B1 135A S801 S811 G B1 cD C 180A 801 S811 8C FIE E 240A S8801 8811 G1 F1E E 304A S8801 8811 G1 FIE E 360A 801 S811 CG1 FIE E 420A S8801 8811 DG1 FIE E 500A S8801 8811 G1 F1E FIEE 650A 801 S811_ G1 10 F1E F1E 720A S801 S811 G1 10 F1E F1E 850A S8801 8811 G1 10 F1E FIE 1000A S8801 8811 G1 10 FIE F1E Enclosure space will also accommodate for an IT Power Supply two 4 pole relays CPT and terminal blocks Also includes space for a DNA module or MOV Same as footnote but CPT is not included Upsize to 7A enclosure to include space for a CPT and a full voltage bypass contactor Enclosure may be reduced to an A1 with all space for all items as in footnote
2. Phase Reversal The S811 can determine if the proper line phase sequence is present by default The device will trip if the line phase sequence is something other than A B C The S811 can be config ured to operate under reversed phase conditions A C B Shorted SCR Detection The S811 monitors the operation of the power poles and will trip under a shorted SCR condition Open SCR Detection The S811 monitors the operation of the power poles and will trip under an open SCR condition Low Current Low current conditions can be a result of a loss of load or a failure in the mechanical system The S811 has low current protection that will trip if the average RMS current falls below a pre set value The low current protection can be programmed as a percent of motor FLA from 0 to 100 Low Voltage Low voltage conditions can result from disturbances in the electrical power distribution system Low voltage conditions can cause a malfunction and damage to electrical equipment The S811 has low voltage protection that will trip if the average RMS volt age falls below a preset value The low voltage protection can be pro grammed as a percent of nominal voltage from 1 to 99 with a trip delay of 0 1 to 60 seconds For more information visit www EatonElectrical com E T N Cutler Hammer January 2005 High Voltage High voltage conditions can result from disturbances in the electrical power distribution system
3. excluding relays and CPTs Same as footnote but CPT is not included Upsize to B1 enclosure to include space for a CPT and a full voltage bypass contactor Note See Enclosed Control Catalog for Box Dimensions for Type 1 3R 4X 7 9 and 12 Options Cover Control Discount Symbol CA03902004E For more information visit www EatonElectrical com E T N Cutler Hammer Reduced Voltage Motor Starters Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters January 2005 CA03902004E For more information visit www EatonElectrical com 95 Reduced Voltage Motor Starters E T N Cutler dammer Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters January 2005 For more information visit www EatonElectrical com CA03902004E E T N Cutler Hammer Reduced Voltage Motor Starters Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters January 2005 CA03902004E For more information visit www EatonElectrical com Eaton Electrical Inc 1000 Cherrington Parkway Moon Township PA 15108 4312 USA tel 1 800 525 2000 www EatonElectrical com 2005 Eaton Corporation All Rights Reserved Printed in USA Publication No CA03902004E CPG January 2005 E T N Cutler Hammer
4. Eaton Consult Eaton Options Cover Control Dimensions Discount Symbol For more information visit www EatonElectrical com 20 Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters Table 25 Class ECS94 811 T Soft Starter Enclosures Type 4X and 12 Reduced Voltage Motor Starters E T N Cutler Hammer January 2005 Amps Motor hp Coil Switch Type 4X Type 12 Component Soft Voltage Voltage Rating Starter Open Catalog Price Catalog Price Catalog Number U S Number U S Number Frame Size 65 mm 37A 200V 3 24V DC 30A ECS9404EAB 7 170 ECS9408EAB 5 700 S811N37N3S 10 60A ECS9404EAD 7 170 ECS9408EAD 5 700 230V 7 1 2 30A ECS9404BAB 7 170 ECS9408BAB 5 700 S811N37N3S 10 60A ECS9404BAD 7 170 ECS9408BAD 5 700 460V 15 30A ECS9404CAC 7 170 ECS9408CAC 5 700 S811N37N3S 25 60A ECS9404CAE 7 170 ECS9408CAE 5 700 575V 20 30A ECS9404DAC 7 170 ECS9408DAC 5 700 S811N37N3S 30 60A ECS9404DAE 7 170 ECS9408DAE 5 700 66A 200V 10 24V DC 60A ECS94S4EAD 8 600 ECS94S8EAD 6 900 S811N66N3S 20 100A ECS94S4EAF 8 600 ECS94S8EAF 6 900 230V 15 60A ECS94S4BAD 8 600 ECS94S8BAD 6 900 S811N66N3S 20 100A ECS94S4BAF 8 600 ECS94S8BAF 6 900 460V 50 100A ECS94S4CAG 8 600 ECS94S8CAG 6 900 S811N66N3S 575V 40 60A ECS94S4DAE 8 600 ECS94
5. ON Pushbutton M 180 00 C400T4 44 75 with Red RUN Pilot Light c 360 00 OFF Pushbutton N 180 00 C400T5 44 75 with Red RUN Green OFF Lights D 540 00 Red RUN Pilot Light P 180 00 C400T9 129 00 Green OFF Q 180 00 C400T10 121 00 Red RUN Green OFF Pilot Lights R 320 00 C400T11 240 00 ON OFF Pushbuttons E 180 00 C400T2 65 00 START STOP Selector Switch S 180 00 C400T13 65 00 with Red RUN Pilot Light F 360 00 with Red RUN Pilot Light T 360 00 with Red RUN Green OFF Lights G 540 00 with Red RUN Green OFF Lights U 540 00 HAND OFF AUTO Selector Switch H 180 00 C400T12 65 00 ON OFF Selector Switch v 180 00 C400T14 65 00 with Red RUN Pilot Light J 360 00 with Red RUN Pilot Light Ww 360 00 with Red RUN Green OFF Lights K 540 00 with Red RUN Green OFF Lights X 540 00 Add Code Letter from the table below to Catalog Number for voltage Kits only Example C400T9B Rating Code Letter Rating Code Letter Rating Code Letter 120V 60 Hz A 240V 60 Hz B 480V 60 Hz c 208V 60 Hz E 380V 50 Hz L 600V 60 Hz D Catalog Number Selection Table 21 Solid State Enclosed Control Catalog Numbering System Type Disconnect Fuse Clip Ratings S Solid State A None G 100A 600V R N 600A 600V R B 30A 250VR_ H 200A 250VR P 800A 600V L C 30A 600VR J 200A 600V R Q 1200A 600V L Class Page D 60A 250VR K 400A 250VR R 1600A 600V L
6. Q Lower shock to product on con veyor lines and material handling gear Q Able to catch motors and fans on the fly and control their acceleration m Electrical system improvements a Limits the peak inrush current as required by many local codes Q Helps to eliminate sags on the plant electrical grid when starting large loads thus avoiding brown out conditions m 24V DC advantages Q Offers improved personnel safety by eliminating the need for 120V AC in the enclosure Q Soft Starter able to ride through 50 voltage conditions indefi nitely due to 24V DC power supply and 0 for up to 100 mS m 690V option available on 180 Amp rating and larger For more information visit www EatonElectrical com Standards and Certifications m UL 508 m IEC 947 4 2 m EN 60947 2 m CE Marked EMC LV Directives m CSA 22 2 m ABS Type Approved Options Pump Control Option m Designed to reduce water hammer during start up and stopping sequences E Stop ramp extended to 120 seconds to help control larger motors and systems with long piping runs LCD Display m 2 line x 20 character LED back lit LCD display m NEMA 4 rated mg Parameters Q Voltage L L AB BC AC Q Phase Current Q Average Current Q Overload Current Setting Q Pole Temperature Q Relay Trip Class Q Thermal Pile Q Fault History Q Average line current as a of FLA a DC Control Voltage Q Start Count m English or Spanish version Tab
7. m Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs Bypass contactor directly connects the motor to the line and improves system efficiency by reducing internal power losses g Internal solid state overload protec tion provides accurate current mea surement and trip settings Sophisticated algorithms solve a series of differential equations that model true motor heating and cool ing resulting in superior motor overload protection while minimiz ing nuisance trips Advanced select able protective features safeguard the motor and system against a variety of system faults CA03902004E E T N Cutler Hammer January 2005 E Internal run bypass contactors and overload protection eliminate the need for additional devices reduc ing enclosure sizes minimizing installation and wiring time and reducing overall assembly size and cost m Wide range of overload FLA settings 31 100 of rated current and a selectable trip class 5 30 offers users the flexibility to fine tune the starter to match specific application requirements m Variable ramp times and torque con trol settings provide unlimited start ing configurations allowing for maximum application flexibility m Kick start feature enables soft start ing of high friction loads m Soft stop control for applications where an abrupt stop of the load is not acceptable m Pump control option with sophisti
8. 93 Non combination IT Soft Start 17 E 60A 600VR L 400A 600VR S 2000A 600V L 94 Combination IT Soft Start with 19 F 100A 250V R M 600A 250V R Ts by Description Fusible Disconnect Breaker 95 Combination IT Soft Start with HMCP 21 A None F 50A L 600A B 3A G 100A P 1200A Amps C 7A H 150A Q 1600A Sai D 15A J 250A Enclosure Type E 30A K 400A Q 37 Z 240 5 650 1 Type 1 S 66 1 304 6 720 V 105 2 360 7 850 2 Type 3R Cover Control W 135 3 420 8 1000 3 Type 4 See Table 20 for Options Y 180 4 500 Type 1X 6 Type 7 9 8 Type 12 Voltage 9 Type 4X 316 Stainless Steel B 230V E 200V C 460V Q 24V DC D 575V Discount Symbol 0005 1CD1C For more information visit www EatonElectrical com CA03902004E E T N Cutler Hdammer Reduced Voltage Motor Starters Solid State Starters Enclosed Type S811 Intelligent Technologies T Soft Starters January 2005 Product Selection Non combination Table 22 Class ECS93 811 T Soft Starter Enclosures Type 1 3R and 4X Amps Motor hp Coil Type 1 Type 3R Type 4X Component Soft Voltage Voltage Starter Open Catalog Price Catalog Price Catalog Price Catalog Number U S Number U S Number U S Number Frame Size 65 mm 37A 200V 10 24V DC ECS93Q1EAA 2 900 ECS93Q2EAA 3 100 ECS93Q4EAA
9. DIM Description Catalog Price Number U S Blank Cover Filler EMA68 52 50 DIM EMA91 332 00 Panel Mounting Kit 3 ft Cable EMA69A 175 00 5 ft Cable EMA69B 198 00 8 ft Cable EMA69C 220 00 10 ft Cable EMA69D 243 00 EML28 EML30 EML32 EML33 Control Wire Connector Table 13 Control Wire Connector Description Catalog Price Number U S 12 pin 5mm pitch EMA75L 15 00 Connector for Control Wiring User Manual A comprehensive user manual is avail able and can be downloaded free of charge from www EatonElectrical com by performing a document search for MN03902002E For more information visit www EatonElectrical com E T N Cutler Hammer January 2005 Mounting Plates The Mounting Plates are designed to help make it easy to install or retrofit the soft starter into enclosures and MCCs The soft starter can be mounted onto the plate prior to installation The mounting plate is designed with tear drop mounting holes for easier installation Table 14 Mounting Plates Description Catalog Price Number U S Mounting Plate N Frame EMM13N 55 00 Mounting Plate R Frame EMM13R 76 00 Mounting Plate T Frame EMM13T 84 50 Mounting Plate V Frame EMM13V 109 00 Fan Hood Accessory EMM18 141 00 Vibration Plates The Vibration Plates allow the soft starter to be applied in high shock and vibration applications The vibration plate allows vibration up
10. Enclosed Type 811 Intelligent Technologies T Soft Starters Table 27 Class ECS95 811 T Soft Starter Enclosures Type 7 9 and 12 Continued Amps Motor hp Coil Circuit Type 7 9 Type 12 Component Soft Voltage Voltage Breaker Starter Open Type Catalog Price _ Catalog Catalog Number U S Number Number Frame Size 290 mm 360A 200V 125 24V DC HMCP 600A ECS9528EAL 21 300 811V36N3S 230V 150 HMCP 600A ECS9528BAL 21 300 460V 300 HMCP 600A ECS9528CAL 21 300 575V 350 HMCP 600A ECS9528DAL 21 300 420A 200V 150 24V DC HMCP 600A ECS9538EAL 24 600 S811V42N3S 230V 150 HMCP 600A ECS9538BAL 24 600 460V 350 HMCP 600A ECS9538CAL 24 600 575V 450 HMCP 600A ECS9538DAL 24 600 500A 200V 150 24V DC HMCP 600A ECS9548EAL 27 300 S811V50N3S 230V 200 HMCP 600A ECS9548BAL 27 300 460V 400 HMCP 600A ECS9548CAL 27 300 575V 500 HMCP 600A ECS9548DAL 27 300 650A 200V 200 24V DC HMCP 1200A ECS9558EAP 33 700 S811V65N3S 230V 250 HMCP 1200A ECS9558BAP 33 700 460V 450 HMCP 600A ECS9558CAL 33 700 460V 500 HMCP 1200A ECS9558CAP 33 700 575V 600 HMCP 1200A ECS9558DAP 33 700 720A _ 460V 600 24V DC HMCP 1200A ECS9568CAP 39 500 811V72N3S 575V 700 HMCP 1200A ECS9568DAP 39 500 850A _ 460V 700 24V DC HMCP 1200A ECS9578CAP 44 300 S811V85N3S 575V 800 HMCP 1200A ECS9578DAP 44 300 1000A 230V 400 24V DC RD 1600 ECS9588BAQ 48 200 811V10N3S 460V 800 RD 1600 ECS9588CAQ 48 200 575V 1000 RD 1600 ECS9588DAQ 48 200
11. locked rotor current and the duration of the current limit Bypass contactors close after current limit time m Maximum current of 0 85 locked rotor current m Adjustable ramp time 0 5 180 seconds can be extended with factory modification Kick Start Selectable feature in both Voltage Ramp Start and Current Limit Start modes Provides a current and torque kick for 0 to 2 0 seconds This pro vides greater initial current to develop additional torque to breakaway a high friction load m 0 85 of locked rotor torque m 0 2 0 seconds duration Soft Stop Allows for a controlled stopping of a load Used when a stop time that is greater than the coast to stop time is desired Often used with high friction loads where a sudden stop may cause system or load damage Em Stop time 0 60 seconds For more information visit www EatonElectrical com 100 Run FLA b Initial Torque Locked Rotor Torque lz Ramp ral Time Seconds Figure 2 Starting Characteristics Ramp Start Max Allowed 2 5 Run 100 i FLA i l l i Time Seconds Figure 3 Starting Characteristics Current Limit Start 100 oO a g e 5 ac o o x 3 Run FLA a e Kick le jamb Start Time Seconds Figure 4 Starting Characteristics Kick Start lt Ramp gt l Time Seconds Figure 5 Starting Characteristics Soft
12. motor protection and fewer nuisance trips The S811 calculates a thermal memory value A 100 value represents the maximum safe temperature of the motor When the thermal memory value reaches 100 an overload trip will occur removing power to the motor Upon trip the S811 stores the calculated motor heating value and will not allow a motor re start until the motor has sufficiently cooled This fea ture ensures the motor will not be damaged by repeated overload trip reset and re start cycles The thermal memory value can be monitored through the DIM or the communications network The thermal memory value can be of great use in determining an impending overload trip condition Alarms can be imple mented in the process monitoring system warning of an impending trip before a trip occurs halting the pro cess Costly system downtime can be avoided The trip current is adjusted to match the specific application requirements by entering the motor nameplate full load current rating and trip class The FLA adjustment includes a 3 to 1 adjustment range The overload trip class is adjustable from class 5 through class 30 The overload is ambient temperature compensated meaning its trip characteristics will not vary with changes in ambient temperature The overload protection can be enabled disabled or disabled on start For more information visit www EatonElectrical com Short Circuit The use of a short circuit protectiv
13. 100 24VDC 400A ECS9511EAK 16 500 ECS9512EAK 18 300 ECS9514EAK 22 000 S811T30N3S 230V 100 400A ECS9511BAK 16 500 ECS9512BAK 18 300 ECS9514BAK 22 000 460V 250 400A ECS9511CAK 16 500 ECS9512CAK 18 300 ECS9514CAK 22 000 575V 300 400A ECS9511DAK 16 500 ECS9512DAK 18 300 ECS9514DAK 22 000 AIl IT soft starters are furnished with 24V DC Based on 1 0 Service Factor For 1 15 consult coils and control power supplies For 24V DC Eaton separate control use Mod Code C35 and These are the Catalog Numbers for Type 4X change the 8th digit to Q i e ECS95S1EAF 304 Grade Stainless Steel as indicated by becomes ECS95S1QAF C35 the seventh digit 4 Example ECS95S4EAF Standard duty horsepower ratings are for To order Type 4X 316 Grade Stainless Steel 300 ramp current 30 seconds ramp change that digit to 9 To order Type 4 time and 3 starts per hour Consult Eaton Painted Steel change that digit to 3 To OPtiONS sigran pirau Aaaa ks for other ratings order Nonmetallic change that digit to 5 Cover Control Dimensions Discount Symbol CA03902004E For more information visit www EatonElectrical com a Reduced Voltage Motor Starters E TeN Cutler Hammer Solid State Starters January 2005 Enclosed Type 811 Intelligent Technologies T Soft Starters Table 26 Class ECS95 811 T Soft Starter Enclosures Type 1 3R and 4X Continued Amps Motor hp Coil C
14. 100A ECS95V1EAG 8 300 ECS95V2EAG 9 500 ECS95V4EAG 11 900 S811R10N3S 30 150A ECS95V1EAH 8 300 ECS95V2EAH 9 500 ECS95V4EAH 11 900 ECS95V1BAG ECS95V2BAG 9 500 ECS95V4BAG 11 900 S811R10N3S ECS95V1BAH ECS95V2BAH 9 500 ECS95V4BAH 11 900 ECS95V1CAG ECS95V2CAG 9 500 ECS95V4CAG 11 900 S811R10N3S ECS95V1CAH ECS95V2CAH 9 500 ECS95V4CAH 11 900 ECS95V1DAG ECS95V2DAG 9 500 ECS95V4DAG 11 900 S811R10N3S ECS95V1DAH ECS95V2DAH 9 500 ECS95V4DAH 11 900 ECS95W1EAH ECS95W2EAH 11 500 ECS95W4EAH 14 300 S811R13N3S ECS95W1BAH ECS95W2BAH 11 500 ECS95W4BAH 14 300 ECS95W1CAH ECS95W2CAH 11 500 ECS95W4CAH 14 300 ECS95W1DAH ECS95W2DAH 11 500 ECS95W4DAH 14 300 Frame Size 200 mm 180A 200V 60 24VDC 250A ECS95Y1EAJ 12 200 ECS95Y2EAJ 14 000 ECS95Y4EAJ 18 000 S811T18N3S 230V 60 250A ECS95Y1BAJ 12 200 ECS95Y2BAJ 14 000 ECS95Y4BAJ 18 000 460V 150 250A ECS95Y1CAJ 12 200 ECS95Y2CAJ 14 000 ECS95Y4CAJ 18 000 575V 150 250A ECS95Y1DAJ 12 200 ECS95Y2DAJ 14 000 ECS95Y4DAJ 18 000 240A 200V 75 24VDC 250A ECS95Z1EAJ 14 500 ECS95Z2EAJ 16 300 ECS95Z4EAJ 19 800 S811T24N3S 230V 75 250A ECS95Z1BAJ 14 500 ECS95Z2BAJ 16 300 ECS95Z4BAJ 19 800 460V 200 400A ECS95Z1CAK 14 500 ECS95Z2CAK 16 300 ECS95Z4CAK 19 800 575V 250 250A ECS95Z1DAJ 14 500 ECS95Z2DAJ 16 300 ECS95Z4DAJ 19 800 304A 200V
15. 4 280 S811N37N3S 230V 10 ECS93Q1BAA 2 900 ECS9302BAA 3 100 ECS9304BAA 4 280 460V 25 ECS93Q1CAA 2 900 ECS9302CAA 3 100 ECS9304CAA 4 280 575V 30 ECS93Q1DAA 2 900 ECS9302DAA 3 100 ECS9304DAA 4 280 66A 200V 20 24V DC ECS93S1EAA 4 250 ECS93S2EAA 5 000 ECS93S4EAA 6 500 S811N66N3S 230V 20 ECS93S1BAA 4 250 ECS93S2BAA 5 000 ECS93S4BAA 6 500 460V 50 ECS93S1CAA 4 250 ECS93S2CAA 5 000 ECS93S4CAA 6 500 575V 60 ECS93S1DAA 4 250 ECS93S2DAA 5 000 ECS93S4DAA 6 500 Frame Size 110 mm 105A 200V 30 24V DC ECS93V1EAA 6 600 ECS93V2EAA 7 000 ECS93V4EAA 9 350 S811R10N3S 230V 40 ECS93V1BAA 6 600 ECS93V2BAA 7 000 ECS93V4BAA 9 350 460V 75 ECS93V1CAA 6 600 ECS93V2CAA 7 000 ECS93V4CAA 9 350 575V 100 ECS93V1DAA 6 600 ECS93V2DAA 7 000 ECS93V4DAA 9 350 135A 200V 40 24V DC ECS93W1EAA 7 950 ECS93W2EAA 8 750 ECS93W4EAA 11 250 S811R13N3S 230V 50 ECS93W1BAA 7 950 ECS93W2BAA 8 750 ECS93W4BAA 11 250 460V 100 ECS93W1CAA 7 950 ECS93W2CAA 8 750 ECS93W4CAA 11 250 575V 125 ECS93W1DAA 7 950 ECS93W2DAA 8 750 ECS93W4DAA 11 250 Frame Size 200 mm 180A 200V 60 24V DC ECS93Y1EAA 9 100 ECS93Y2EAA 10 200 ECS93Y4EAA 13 100 S811T18N3S 230V 60 ECS93Y1BAA 9 100 ECS93Y2BAA 10 200 ECS93Y4BAA 13 100 460V 150 ECS93Y1CAA 9 100 ECS93Y2CAA 10 200 ECS93Y4CAA 13 100 575V 150 ECS93Y1DAA 9 100 ECS93Y2DAA 10 200 ECS93Y4DAA 13 100 240A 200V 75 24V DC ECS93Z1E
16. 500 MCM Type of Connectors Box Lug Add On Lug Kit Control Wiring 12 Pin Wire Sizes in AWG 22 14 Number of Conductors 2 Stranded or one AWG 12 Torque Requirements 3 5 in Ib in Solid Stranded or Flexible 3 31 Max Size in mm2 Control Power Requirements Voltage Range 24V 10 21 6 26 4 Steady State Current Amps 1 0 1 0 1 0 1 4 Inrush Current Amps 10 10 10 10 Ripple 1 Relays 1 Class A and C Voltage AC maximum 240 Voltage DC maximum 120 Amps maximum UR Recognized Product CA03902004E For more information visit www EatonElectrical com Reduced Voltage Motor Starters E T N Cutler dammer Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters 12 January 2005 Table 18 Specifications T Soft Starter Continued Soft Starter 811 811 811 811 811 811 811 811 811 811 811 811 811 811 Partial Catalog Number N37 N66 R10 R13 T18 T24 T30 V36 V42 v50 v65 V72 v85 v10 Max Current Capacity 37 66 105 135 180 240 304 360 420 500 650 720 850 1000 Environment Temperature Operating 30 50 C No derating Consult factory for operation gt 50 C Temperature Storage 50 70 C Altitude lt 2000 Meters Consult factory for operation gt 2000m Humidity lt 95 Non conden
17. 600A ECS9551CAL 26 500 ECS9552CAL 33 700 ECS9554CAL 41 600 460V 500 HMCP 1200A ECS9551CAP 26 500 ECS9552CAP 33 700 ECS9554CAP 41 600 575V 600 HMCP 1200A ECS9551DAP 26 500 ECS9552DAP 33 700 ECS9554DAP 41 600 720A 460V 600 24V DC HMCP 1200A ECS9561CAP 30 700 ECS9562CAP 39 500 ECS9564CAP 47 100 811V72N3S 575V 700 HMCP 1200A ECS9561DAP 30 700 ECS9562DAP 39 500 ECS9564DAP 47 100 850A 460V 700 24V DC HMCP 1200A ECS9571CAP 35 000 ECS9572CAP 44 300 ECS9574CAP 50 600 S811V85N3S 575V 800 HMCP 1200A ECS9571DAP 35 000 ECS9572DAP 44 300 ECS9574DAP 50 600 1000A 230V 400 24V DC RD 1600 ECS9581BAQ 39 500 ECS9582BAQ 48 200 ECS9584BAQ 55 600 8811V10N3S 460V 800 RD 1600 ECS9581CAQ 39 500 ECS9582CAQ 48 200 ECS9584CAQ 55 600 575V 1000 RD 1600 ECS9581DAQ 39 500 ECS9582DAQ 48 200 ECS9584DAQ 55 600 AIl IT soft starters are furnished with 24V DC coils and control power supplies For 24V DC separate control use Mod Code C35 and change the 8th digit to Q i e ECS95S1EAF becomes ECS95S1QAF C35 Standard duty horsepower ratings are for 300 ramp current 30 seconds ramp time and 3 starts per hour Consult Eaton for other ratings Based on 1 0 Service Factor For 1 15 consult Eaton These are the Catalog Numbers for Type 4X 304 Grade Stainless Steel as indicated by the seventh digit 4 Example ECS95S4EAA To order Type 4X 316 Grade Stainless Steel
18. ECS9424CAN 27 500 ECS9428CAN 22 000 575V 350 600A ECS9424DAN 27 500 ECS9428DAN 22 000 420A 200V 150 24V DC 600A ECS9434EAM 31 000 ECS9438EAM 25 400 S811V42N3S 230V 150 600A ECS9434BAM 31 000 ECS9438BAM 25 400 460V 350 600A ECS9434CAN 31 000 ECS9438CAN 25 400 575V 450 600A ECS9434DAN 31 000 ECS9438DAN 25 400 500A 200V 150 24V DC 800A ECS9444EAP 35 000 ECS9448EAP 29 300 S811V50N3S 230V 200 800A ECS9444BAP 35 000 ECS9448BAP 29 300 460V 400 800A ECS9444CAP 35 000 ECS9448CAP 29 300 575V 500 800A ECS9444DAP 35 000 ECS9448DAP 29 300 650A 460V 500 24V DC 800A ECS9454CAP 42 600 ECS9458CAP 34 700 S811V65N3S 575V 600 800A ECS9454DAP 42 600 ECS9458DAP 34 700 720A 460V 600 24V DC 1200A ECS9464CAQ 43 500 ECS9468CAQ 35 500 S811V72N3S 575V 700 1200A ECS9464DAQ 43 500 ECS9468DAQ 35 500 850A 460V 700 24V DC 1600A ECS9474CAR 45 800 ECS9478CAR 36 400 S811V85N3S 575V 800 1600A ECS9474DAR 45 800 ECS9478DAR 36 400 1000A 230V 400 24V DC ECS9484BA_ 49 500 ECS9488BA_ 39 900 S811V10N3S 460V 800 ECS9484CA_ 49 500 ECS9488CA_ 39 900 575V 1000 ECS9484DA_ 49 500 ECS9488DA_ 39 900 AIl IT soft starters are furnished with 24V DC Based on 1 0 Service Factor For 1 15 consult coils and control power supplies For 24V DC Eaton separate control use Mod Code C35 and These are the Catalog Numbers for Type 4X change the 8th digit to Q i e ECS94S1EAD 304 Grade Stainless St
19. Stop CA03902004E E T N Cutler Hammer Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters January 2005 Catalog Number Selection Table 1 811 Open Soft Starters Catalog Numbering System 811T30N3S S IT Soft Starter S Standard Soft Starter edge sensing is default of selectable setting L Extended Ramp Start W Without DIM 811 Non combination Soft Starter 3 3 Pole Device N No Options P Pump Control Ampacity Rating V 690V Option 37 37 amps 36 360 amps Frame T18 through V85 66 66 amps 42 420 amps 10 105 amps 50 500 amps 13 135 amps 65 650 amps 18 180 amps 72 720 amps 24 240 amps 85 850 amps 30 304 amps 10 1000 amps CA03902004E For more information visit www EatonElectrical com g Reduced Voltage Motor Starters E T N Cutler Hammer Solid State Starters January 2005 Open Type S811 Intelligent Technologies IT Soft Starters Product Selection is capable of If the application falls under these categories you can use Motor applications and customer needs these charts For other applications or come in many different varieties With when a question arises consult with the standard and severe duty rating your local Eaton Representative or call
20. cated pump algorithms on both starting and stopping that minimize the pressure surges that cause water hammer The pump control option will maximize the life of the pump and piping systems while minimizing the downtime caused by system failure m Six SCRs control all three motor phases providing smooth accelera tion and deceleration performance m Soft acceleration and deceleration reduces wear on belts gears chains clutches shafts and bearings m Reduce the peak inrush current s stress on the power system m Minimize peak starting torque to diminish mechanical system wear and damage m 24V DC control module enhances personnel and equipment safety m Removable lockable control termi nal block reduces maintenance costs Also provides the opportunity for OEMs to reduce assembly and test costs by utilizing pre assembled wire harnesses CA03902004E Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters Protective Features All protective features can be config ured enabled or disabled with the DIM or through the communications network Motor Overload The S811 includes electronic overload protection as standard The overload meets applicable requirements for a motor overload protective device The overload protects the motor from over heat conditions with the use of sophis ticated algorithms that model true motor heating resulting in superior
21. change that digit to 9 To order Type 4 Painted Steel change that digit to 3 To order Nonmetallic change that digit to 5 Options Cover Control Dimensions Discount Symbol For more information visit www EatonElectrical com CA03902004E E T N Cutler Hammer Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters January 2005 Table 27 Class ECS95 811 T Soft Starter Enclosures Type 7 9 and 12 Reduced Voltage Motor Starters Coil Voltage Circuit Breaker Type Amps Motor hp Voltage Type 7 9 Catalog 1 0 Number S F Frame Size 65 mm Type 12 Catalog Number Component Soft Starter Open Catalog Number 37A 200V 1 2 24VDC J3A ECS9506EAB 9 600 ECS9508EAB 5 950 S811N37N3S 1 7A ECS9506EAC 9 600 ECS9508EAC 5 950 3 15A ECS9506EAD 9 600 ECS9508EAD 5 950 7 1 2 30A ECS9506EAE 9 600 ECS9508EAE 5 950 10 50A ECS9506EAF 9 600 ECS9508EAF 5 950 230V 1 2 2avDC 3A ECS9506BAB 9 600 ECS9508BAB 5 950 S811N37N3S 1 7A ECS9506BAC 9 600 ECS9508BAC 5 950 3 15A ECS9506BAD 9 600 ECS9508BAD 5 950 7 1 2 30A ECS9506BAE 9 600 ECS9508BAE 5 950 10 50A ECS9506BAF 9 600 ECS9508BAF 5 950 460V 3 4 24VDC 3A ECS9506CAB 9 600 ECS9508CAB 5 950 S811N37N3S 3 7A ECS9506CAC 9 600 ECS9508CAC 5 950 7 1 2 15A ECS9506CAD 9 600 ECS9508CAD 5 950 15 30A ECS9506CAE 9 600 ECS9508CAE 5 950 25 50A EC
22. changes can prompt maintenance and aid in process evaluation activities Device Temperature An increase in device temperature is a strong indication of an increase in ambient temperature High ambient temperature operation can be identi fied with the Device Temperature data Ambient temperature increases can be due to loss of enclosure cooling fans or blocked venting High ambient temperatures will reduce the life of all electrical equipment in the enclosure Start Count Start count data can be used to monitor system output schedule preventative maintenance identify system anomalies and identify changes in system operation For more information visit www EatonElectrical com Diagnostics Fault Queue Current fault and a fault queue con taining the last nine system faults can be read through the DIM or communi cations network Fault identification can minimize troubleshooting time and cost The fault queue can be remotely accessed through a commu nications network to assist in planning maintenance resources 30 different faults can be identified by the S811 Control Status The S811 provides data that repre sents system conditions that can be read through the DIM or the communi cations network This data identifies the status of the system and the con trol commands the system is request ing of the S811 This can be used for advanced troubleshooting and system integration activities Breaker Status The
23. s electrical business offers all the popular features of the S801 but adds enhanced functionality with the new DIM Digital Interface Module and communications capabilities The Cutler Hammer Intelligent Technologies T Line of S811 Reduced Voltage Soft Starters is very compact multi functional easy to install and easy to program Designed to control the acceleration and deceleration of three phase motors up to 690V the line is available from 11 amps through 1 000 amps The S811 is designed to be a complete package combining the SCRs bypass contactor and overload in one very compact unit The 811 is available as a component for panel mounting in motor control centers or in enclosed control NEMA Type 1 3R 4 4X 7 9 and 12 Application Description Designed to control the acceleration and deceleration of three phase motors the IT S811 soft starter uses Silicon Controlled Rectifiers SCRs to control the voltage to soft start and soft stop the motor After the motor is started internal run bypass contactors close resulting in the motor running directly across the line The built in solid state overload protects the motor from overload conditions with sophis ticated algorithms that model true motor heating resulting in better motor protection and fewer nuisance trips Advanced protective and diag nostic features reduce downtime A voltage ramp start or current limit start is available Kick start is ava
24. tables we have attempted to provide our Technical Resource Center guidelines on what the IT Soft Starter Table 2 Standard Duty Ratings Starting Method Ramp Current Ramp Time Starts per Ambient of FLA Seconds Hour Temperature vs Soft Start 300 30 sec 3 50 C vs Full Voltage 500 10 sec 3 50 C vs Wye Delta 350 20 sec 3 50 C vs 80 RVAT 480 20 sec 2 50 C vs 65 RVAT 390 20 sec 3 50 C vs 50 RVAT 300 20 sec 4 50 C Table 3 Product Selection Standard Duty Rating Open Soft Starters Frame Max Three Phase Motor Catalog Price Size Current kW Rating 50 Hertz hp Rating 60 Hertz Number U S 230 380 400 440 200V 230V 460V 575V Volt Volt Volt 1 0SF 1 15SF 1 0SF 1 15SF 1 0SF 1 15SF 1 0SF 1 15SF N 37 10 18 5 18 5 10 10 10 10 25 20 30 30 811N37N3S 1 890 66 18 5 30 37 20 15 20 20 50 40 60 50 S811N66N3S 2 905 R 105 30 55 59 30 25 40 30 75 60 100 75 811R10N3S 4 385 135 40 63 80 40 30 50 40 100 75 125 100 811R13N3S 5 250 T 180 51 90 110 60 50 60 60 150 125 150 150 811T18N3S 5 580 240 75 110 147 75 60 75 75 200 150 200 200 811T24N3S 5 940 304 90 160 185 100 75 100 100 250 200 300 250 811T30N3S 6 310 V 360 110 185 220 125 100 150 125 300 250 350 300 811V36N3S 7 350 420 129 220 257 150 125 175 150 350 300 450 350 811V42N3S 8 280 500 150 257 300 150 150 200 150 400 350 500 450 811V50N3S 9 310 650 200 355 425 250 200 250 200 500 450 600 500 811V65N3S 10 480 720 220 400 450 300 250 600 500 70
25. 0 ECS9342DAA 18 900 ECS9344DAA 22 900 650A 200V 250 24V DC ECS9351EAA 18 400 ECS9352EAA 21 300 ECS9354EAA 28 000 S811V65N3S 230V 250 ECS9351BAA 18 400 ECS9352BAA 21 300 ECS9354BAA 28 000 460V 500 ECS9351CAA 18 400 ECS9352CAA 21 300 ECS9354CAA 28 000 575V 600 ECS9351DAA 18 400 ECS9352DAA 21 300 ECS9354DAA 28 000 720A 230V 300 24V DC ECS9361BAA 19 900 ECS9362BAA 30 400 ECS9364BAA 37 100 S811V72N3S 460V 600 ECS9361CAA 19 900 ECS9362CAA 30 400 ECS9364CAA 37 100 575V 700 ECS9361DAA 19 900 ECS9362DAA 30 400 ECS9364DAA 37 100 850A 230V 350 24V DC ECS9371BAA 22 500 ECS9372BAA 32 400 ECS9374BAA 39 800 S811V85N3S 460V 700 ECS9371CAA 22 500 ECS9372CAA 32 400 ECS9374CAA 39 800 575V 900 ECS9371DAA 22 500 ECS9372DAA 32 400 ECS9374DAA 39 800 1000A 230V 400 24V DC ECS9381BAA 25 000 ECS9382BAA 36 500 ECS9384BAA 43 000 S811V10N3S 460V 800 ECS9381CAA 25 000 ECS9382CAA 36 500 ECS9384CAA 43 000 575V 1000 ECS9381DAA 25 000 ECS9382DAA 36 500 ECS9384DAA 43 000 All IT soft starters are furnished with 24V DC Based on 1 0 Service Factor For 1 15 consult coils and control power supplies For 24V DC Eaton separate control use Mod Code C35 and These are the Catalog Numbers for Type 4X change the 8th digit to Q i e ECS93S1EAA 304 Grade Stainless Steel as indicated by becomes ECS93S10AA C35 the seventh digit 4 Example ECS93S4EAA Standard duty hors
26. 0 24V DC 200A ECS94V1EAH 9 400 ECS94V2EAH 9 500 S811R10N3S 230V 40 200A ECS94V1BAH 9 400 ECS94V2BAH 9 500 460V 75 200A ECS94V1CAJ 9 400 ECS94V2CAJ 9 500 575V 100 200A ECS94V1DAJ 9 400 ECS94V2DAJ 9 500 135A 200V 40 24V DC 200A ECS94W1EAH 9 800 ECS94W2EAH 11 100 S811R13N3S 230V 50 200A ECS94W1BAH 9 800 ECS94W2BAH 11 100 460V 100 200A ECS94W1CAJ 9 800 ECS94W2CAJ 11 100 575V 125 200A ECS94W1DAJ 9 800 ECS94W2DAJ 11 100 Frame Size 200 mm 180A 200V 60 24V DC 400A ECS94Y 1EAK 13 000 ECS94Y2EAK 13 800 S811T18N3S 230V 60 400A ECS94Y1BAK 13 000 ECS94Y2BAK 13 800 460V 150 400A ECS94Y1CAL 13 000 ECS94Y2CAL 13 800 575V 150 400A ECS94Y1DAL 13 000 ECS94Y2DAL 13 800 240A 200V 75 24V DC 400A ECS94Z1EAK 13 700 ECS94Z2EAK 15 500 S811T24N3S 230V 75 400A ECS94Z1BAK 13 700 ECS94Z2BAK 15 500 460V 200 400A ECS94Z1CAL 13 700 ECS94Z2CAL 15 500 575V 200 400A ECS94Z1DAL 13 700 ECS94Z2DAL 15 500 304A 200V 100 24V DC 400A ECS9411EAK 15 900 ECS9412EAK 17 700 S811T30N3S 230V 100 400A ECS9411BAK 15 900 ECS9412BAK 17 700 460V 250 400A ECS9411CAL 15 900 ECS9412CAL 17 700 575V 300 400A ECS9411DAL 15 900 ECS9412DAL 17 700 Frame Size 290 mm 360A 200V 125 24V DC 600A ECS9421EAM 20 300 ECS9422EAM 22 000 S811V36N3S 230V 125 600A ECS9421BAM 20 300 ECS9422BAM 22 000 460V 300 600A ECS9421CAN 20 300 ECS9422CAN 22 000 575V 350 600A ECS9421DAN 20 300 ECS9422DAN 22 000 420A 200V 150 24V DC 600A
27. 0 600 811V72N3S 12 040 850 257 475 500 350 300 700 600 900 700 811V85N3S 14 580 1000 315 560 600 400 350 800 700 1000 800 811V10N3S 24 340 For a longer ramp acceleration time of 0 5 to 360 seconds see Page 9 Table 4 Severe Duty Ratings Starting Method Ramp Current Ramp Time Starts per Ambient of FLA Seconds Hour Temperature vs Soft Start 450 30 sec 4 50 C vs Full Voltage 500 10 sec 10 50 C vs Wye Delta 350 65 sec 3 50 C vs 80 RVAT 480 25 sec 4 50 C vs 65 RVAT 390 40 sec 4 50 C vs 50 RVAT 300 60 sec 4 50 C Table 5 Product Selection Severe Duty Rating Open Soft Starters Frame Max Three Phase Motor Catalog Price Size Current kW Rating 50 Hertz hp Rating 60 Hertz Number U S 230 380 400 440 200V 230V 460V 575V Volt Volt Volt 1 0SF 1 15SF 1 0SF 1 15SF 1 0SF 1 15SF 1 0SF 1 15SF N 22 5 5 10 11 5 5 7 1 2 5 15 10 20 15 811N37N3S 1 890 42 11 18 5 22 10 10 15 10 30 25 40 30 S811N66N3S 2 905 R 65 15 30 33 15 15 20 15 50 40 50 50 811R10N3S 4 385 80 22 40 45 25 20 30 25 60 50 75 60 811R13N3S 5 250 T 115 33 59 63 30 30 40 30 75 75 100 100 811T18N3S 5 580 150 45 80 90 50 40 50 50 100 100 150 125 811T24N3S 5 940 192 55 100 110 60 50 75 60 150 125 200 150 S811T30N3S 6 310 V 240 75 110 147 75 60 75 75 200 150 200 200 811V36N3S 7 350 305 90 160 185 100
28. 0A ECS95W6DAH 18 800 ECS95W8DAH 11 500 Frame Size 200 mm 180A 200V 60 24V DC 250A ECS95Y6EAJ 26 000 ECS95Y8EAJ 14 000 S811T18N3S 230V 60 250A ECS95Y6BAJ 26 000 ECS95Y8BAJ 14 000 460V 150 250A ECS95Y6CAJ 26 000 ECS95Y8CAJ 14 000 575V 150 250A ECS95Y6DAJ 26 000 ECS95Y8DAJ 14 000 240A 200V 75 24V DC 250A ECS95Z6EAJ 28 300 ECS95Z8EAJ 16 300 S811T24N3S 230V 75 250A ECS95Z6BAJ 28 300 ECS95Z8BAJ 16 300 460V 200 400A ECS95Z6CAK 28 300 ECS95Z8CAK 16 300 575V 250 250A ECS95Z6DAJ 28 300 ECS95Z8DAJ 16 300 304A 200V 100 24V DC 400A ECS9516EAK 30 400 ECS9518EAK 18 300 S811T30N3S 230V 100 400A ECS9516BAK 30 400 ECS9518BAK 18 300 460V 250 400A ECS9516CAK 30 400 ECS9518CAK 18 300 575V 300 400A ECS9516DAK 30 400 ECS9518DAK 18 300 AIl IT soft starters are furnished with 24V DC coils and control power supplies For 24V DC separate control use Mod Code C35 and change the 8th digit to Q i e ECS95S1EAF becomes ECS95S1QAF C35 2 Standard duty horsepower ratings are for 300 ramp current 30 seconds ramp time and 3 starts per hour Consult Eaton for other ratings Eaton CA03902004E Based on 1 0 Service Factor For 1 15 consult OPTIONS 26 2 seen a EAA Cover Control Dimensions Discount Symbol For more information visit www EatonElectrical com Reduced Voltage Motor Starters E T N Cutler Hammer Solid State Starters January 2005
29. 75 100 100 250 200 300 250 811V42N3S 8 280 365 110 185 220 125 100 150 125 300 250 350 300 S 811V50N3S 9 310 420 129 220 257 150 125 150 150 350 300 450 350 S811V65N3S 10 480 480 147 257 295 150 150 200 150 400 350 500 450 811V72N3S 12 040 525 160 280 335 150 150 200 150 450 350 500 450 S811V85N3S 14 580 600 185 315 375 200 150 250 200 500 450 600 500 811V10N3S 24 340 For a longer ramp acceleration time of 0 5 to 360 seconds see Page 9 Discount Symbol 0008 1CD1 For more information visit www EatonElectrical com CA03902004E E T N Cutler Hammer January 2005 Options Extended Ramp For a longer ramp acceleration time of 5 360 seconds change the last digit in the Catalog Number from Page 8 to L Table 6 Extended Ramp Option Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters Pump Control For pump control option change the 8th digit in the Catalog Number to P Table 8 Pump Control Option Frame Max Catalog Price Size Current Number U S N 37 811N37N3L 2 280 66 811N66N3L 3 295 R 105 811R10N3L 4 775 135 811R13N3L 5 440 T 180 811T18N3L 5 980 240 811T24N3L 6 340 304 811T30N3L 6 700 V 360 811V36N3L 7 750 420 811V42N3L 8 660 500 811V50N3L 9 700 650 811V65N3L 10 870 720 811V72N3L 12 430 850 811V85N3L 14 960 1000 811
30. AA 9 700 ECS93Z2EAA 11 500 ECS93Z4EAA 14 500 S811T24N3S 230V 75 ECS93Z1BAA 9 700 ECS93Z2BAA 11 500 ECS93Z4BAA 14 500 460V 200 ECS93Z1CAA 9 700 ECS93Z2CAA 11 500 ECS93Z4CAA 14 500 575V 200 ECS93Z1DAA 9 700 ECS93Z2DAA 11 500 ECS93Z4DAA 14 500 304A 200V 100 24V DC ECS9311EAA 10 720 ECS9312EAA 13 000 ECS9314EAA 16 300 S811T30N3S 230V 100 ECS9311BAA 10 720 ECS9312BAA 13 000 ECS9314BAA 16 300 460V 250 ECS9311CAA 10 720 ECS9312CAA 13 000 ECS9314CAA 16 300 575V 300 ECS9311DAA 10 720 ECS9312DAA 13 000 ECS9314DAA 16 300 Frame Size 290 mm 360A 200V 125 24V DC ECS9321EAA 13 000 ECS9322EAA 15 500 ECS9324EAA 17 900 S811V36N3S 230V 150 ECS9321BAA 13 000 ECS9322BAA 15 500 ECS9324BAA 17 900 460V 300 ECS9321CAA 13 000 ECS9322CAA 15 500 ECS9324CAA 17 900 575V 350 ECS9321DAA 13 000 ECS9322DAA 15 500 ECS9324DAA 17 900 420A 200V 150 24V DC ECS9331EAA 15 500 ECS9332EAA 17 500 ECS9334EAA 20 700 S811V42N3S 230V 175 ECS9331BAA 15 500 ECS9332BAA 17 500 ECS9334BAA 20 700 460V 350 ECS9331CAA 15 500 ECS9332CAA 17 500 ECS9334CAA 20 700 575V 450 ECS9331DAA 15 500 ECS9332DAA 17 500 ECS9334DAA 20 700 500A 200V 150 24V DC ECS9341EAA 17 200 ECS9342EAA 18 900 ECS9344EAA 22 900 S811V50N3S 230V 200 ECS9341BAA 17 200 ECS9342BAA 18 900 ECS9344BAA 22 900 460V 400 ECS9341CAA 17 200 ECS9342CAA 18 900 ECS9344CAA 22 900 575V 500 ECS9341DAA 17 20
31. E T N Cutler Hammer January 2005 CA03902004E Reduced Voltage Motor Starters Contents Description Open Type 811 Intelligent Technologies T Soft Starters Product Description Application Description Features and Benefits Operation Catalog Number Selection Product Selection Options Accessories Standards and Certifications Instructional Leaflets Technical Data DIMENSIONS ss 3 4 4 denneeessdone eee tee ane deacgcadae eae eee cee Enclosed Type S811 Intelligent Technologies IT Soft Starters Product Description Features and Benefits Standards and Certifications Options Cover Contohe siera bad eee baw eek Poe dee ld oa oh eee ed ee Catalog Number Selection Product Selection 6 0rcaawead eed naw era rnap eee ea Pie bane Dimensions Note Supplement to Publication No CA08102001E Tab 39 om Fi A gt x AU A S811 IT Soft Starter For more information visit www EatonElectrical com Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters 811 Open Soft Starters P e TA CUM Product Description Eaton s Cutler Hammer IT S801 revolutionized the reduced voltage control marketplace with its advanced feature set and small size In fact readers of an industry leading control publication rated Cutler Hammer Soft Starters best in customer satisfaction in March 2004 The new IT S811 from Eaton
32. ECS9431EAM 22 000 ECS9432EAM 25 400 811V42N3S 230V 150 600A ECS9431BAM 22 000 ECS9432BAM 25 400 460V 350 600A ECS9431CAN 22 000 ECS9432CAN 25 400 575V 450 600A ECS9431DAN 22 000 ECS9432DAN 25 400 500A 200V 150 24V DC 800A ECS9441EAP 24 000 ECS9442EAP 29 300 S811V50N3S 230V 200 800A ECS9441BAP 24 000 ECS9442BAP 29 300 460V 400 800A ECS9441CAP 24 000 ECS9442CAP 29 300 575V 500 800A ECS9441DAP 24 000 ECS9442DAP 29 300 650A 460V 500 24V DC 800A ECS9451CAP 27 400 ECS9452CAP 34 700 S811V65N3S 575V 600 800A ECS9451DAP 27 400 ECS9452DAP 34 700 720A 460V 600 24V DC 1200A ECS9461CAQ 24 900 ECS9462CAO 35 500 5811V72N3S 575V 700 1200A ECS9461DAQ 24 900 ECS9462DAQ 35 500 850A 460V 700 24V DC 1600A ECS9471CAR 26 500 ECS9472CAR 36 400 S811V85N3S 575V 800 1600A ECS9471DAR 26 500 ECS9472DAR 36 400 1000A 230V 400 24V DC ECS9481BA_ 29 900 ECS9482BA_ 39 900 S811V10N3S 460V 800 ECS9481CA_ 29 900 ECS9482CA_ 39 900 575V 1000 ECS9481DA_ 29 900 ECS9482DA_ 39 900 AIl IT soft starters are furnished with 24V DC coils and control power supplies For 24V DC separate control use Mod Code C35 and change the 8th digit to Q i e ECS94S1EAD becomes ECS94S1QAD C35 Standard duty horsepower ratings are for 300 ramp current 30 seconds ramp time and 3 starts per hour Consult Eaton for other ratings CA03902004E Based on 1 0 Service Factor For 1 15 consult
33. ECS95Q4EAE 7 440 10 50A ECS95Q1EAF 4 850 ECS9502EAF 5 950 ECS9504EAF 7 440 230V 1 2 24VDC 3A ECS9501BAB 4 850 ECS9502BAB 5 950 ECS9504BAB 7 440 S811N37N3S 1 7A ECS9501BAC 4 850 ECS9502BAC 5 950 ECS9504BAC 7 440 3 15A ECS95Q1BAD 4 850 ECS9502BAD 5 950 ECS9504BAD 7 440 7 1 2 30A ECS95Q1BAE 4 850 ECS9502BAE 5 950 ECS9504BAE 7 440 10 50A ECS95Q1BAF 4 850 ECS9502BAF 5 950 ECS9504BAF 7 440 460V 3 4 24VDC 3A ECS9501CAB 4 850 ECS9502CAB 5 950 ECS9504CAB 7 440 S811N37N3S 3 7A ECS95Q1CAC 4 850 ECS9502CAC 5 950 ECS9504CAC 7 440 7 1 2 15A ECS95Q1CAD 4 850 ECS95Q2CAD 5 950 ECS9504CAD 7 440 15 30A ECS95Q1CAE 4 850 ECS9502CAE 5 950 ECS95Q04CAE 7 440 25 50A ECS95Q1CAF 4 850 ECS9502CAF 5 950 ECS9504CAF 7 440 575V ECS95Q1DAB ECS9502DAB ECS9504DAB 811N37N3S ECS95Q1DAC ECS9502DAC ECS9504DAC ECS9501DAD ECS9502DAD ECS9504DAD ECS9501DAE ECS9502DAE ECS9504DAE ECS95Q1DAF ECS9502DAF ECS9504DAF 66A 200V ECS95S1EAF ECS95S2EAF ECS95S4EAF S811N66N3S ECS95S1EAG ECS95S2EAG ECS95S4EAG 230V ECS95S1BAF ECS95S2BAF ECS95S4BAF S811N66N3S ECS95S1BAG ECS95S2BAG ECS95S4BAG 460V ECS95S1CAG ECS95S2CAG ECS95S4CAG S811N66N3S 575V 40 24VDC 50A ECS95S1DAF 5 900 ECS95S2DAF 7 100 ECS95S4DAF 8 900 S811N66N3S 60 100A ECS95S1DAG 5 900 ECS95S2DAG 7 100 ECS95S4DAG 8 900 Frame Size 110 mm 105A 200V 25 24VDC
34. High volt age conditions can cause malfunctions or failures of electrical equipment The 811 has high voltage protection that will trip if the average RMS voltage is greater than a preset value The high voltage protection can be pro grammed as a percent of nominal voltage from 101 to 120 with a trip delay of 0 1 to 60 seconds Monitoring Capabilities The S811 has an impressive array of system monitoring capabilities that allow users to access real time process and diagnostic data This data can be viewed at the device with the DIM or through a communications network Data over a communications network can provide valuable insight into the condition of the equipment and pro cesses Maintenance and production personnel can monitor critical opera tional and maintenance data from a central control station that can be located far away from the production facility Process data can be monitored to determine system anomalies that may indicate a need for preventive maintenance or an impeding failure Adjustments made through the com munications network can reduce costs by minimizing the time traveling to the location where the motor controls are located When faults do occur real time fault data can assist maintenance in troubleshooting and planning repair resources Remote reset signals can be given to tripped devices without the need for manual intervention by main tenance personnel Average Line Current Provides the ave
35. S811 has provisions to read and display circuit breaker status Cutler Hammer communicating Cover Con trol or other communicating protective device is required to take advantage of this feature Reduced Voltage Motor Starters Solid State Starters E T N Cutler Hammer January 2005 Open Type S811 Intelligent Technologies IT Soft Starters Operation Starting and Stopping Modes The S811 has a variety of starting and stopping methods to provide superior performance in the most demanding applications The motor can be started in either Voltage Ramp Start or Current Limit Start mode Kick Start and Soft Stop are available within both starting modes Voltage Ramp Start Provides a voltage ramp to the motor resulting in a constant torque increase The most commonly used form of soft start this start mode allows you to set the initial torque value and the duration of the ramp to full voltage conditions Bypass contactors close after ramp time m Adjustable initial torque 0 85 of locked rotor torque m Adjustable ramp time 0 5 180 seconds can be extended with factory modification Current Limit Start Limits the maximum current available to the motor during the start phase This mode of soft starting is used when it becomes necessary to limit the maxi mum starting current due to long start times or to protect the motor This start mode allows you to set the maximum starting current as a percentage of
36. S8DAE 6 900 S811N66N3S 60 100A ECS94S4DAG 8 600 ECS94S8DAG 6 900 Frame Size 110 mm 105A 200V 30 24V DC 200A ECS94V4EAH 11 800 ECS94V8EAH 9 500 S811R10N3S 230V 40 200A ECS94V4BAH 11 800 ECS94V8BAH 9 500 460V 75 200A ECS94V4CAJ 11 800 ECS94V8CAJ 9 500 575V 100 200A ECS94V4DAJ 11 800 ECS94V8DAJ 9 500 135A 200V 40 24V DC 200A ECS94W4EAH 14 000 ECS94W8EAH 11 100 S811R13N3S 230V 50 200A ECS94W4BAH 14 000 ECS94W8BAH 11 100 460V 100 200A ECS94W4CAJ 14 000 ECS94W8CAJ 11 100 575V 125 200A ECS94W4DAJ 14 000 ECS94W8DAJ 11 100 Frame Size 200 mm 180A 200V 60 24V DC 400A ECS94Y4EAK 17 600 ECS94Y8EAK 13 800 S811T18N3S 230V 60 400A ECS94Y4BAK 17 600 ECS94Y8BAK 13 800 460V 150 400A ECS94Y4CAL 17 600 ECS94Y8CAL 13 800 575V 150 400A ECS94Y4DAL 17 600 ECS94Y8DAL 13 800 240A 200V 75 24V DC 400A ECS94Z4EAK 19 300 ECS94Z8EAK 15 500 S811T24N3S 230V 75 400A ECS94Z4BAK 19 300 ECS94Z8BAK 15 500 460V 200 400A ECS94Z4CAL 19 300 ECS94Z8CAL 15 500 575V 200 400A ECS94Z4DAL 19 300 ECS94Z8DAL 15 500 304A 200V 100 24V DC 400A ECS9414EAK 21 500 ECS9418EAK 17 700 S811T30N3S 230V 100 400A ECS9414BAK 21 500 ECS9418BAK 17 700 460V 250 400A ECS9414CAL 21 500 ECS9418CAL 17 700 575V 300 400A ECS9414DAL 21 500 ECS9418DAL 17 700 Frame Size 290 mm 360A 200V 125 24V DC 600A ECS9424EAM 27 500 ECS9428EAM 22 000 S811V36N3S 230V 125 600A ECS9424BAM 27 500 ECS9428BAM 22 000 460V 300 600A
37. S93V6BAA 13 020 ECS93V8BAA 7 000 460V 75 ECS93V6CAA 13 020 ECS93V8CAA 7 000 575V 100 ECS93V6DAA 13 020 ECS93V8DAA 7 000 135A 200V 40 24V DC ECS93W6EAA 16 850 ECS93W8EAA 8 750 S811R13N3S 230V 50 ECS93W6BAA 16 850 ECS93W8BAA 8 750 460V 100 ECS93W6CAA 16 850 ECS93W8CAA 8 750 575V 125 ECS93W6DAA 16 850 ECS93W8DAA 8 750 Frame Size 200 mm 180A 200V 60 24V DC ECS93Y6EAA 21 000 ECS93Y8EAA 10 200 S811T18N3S 230V 60 ECS93Y6BAA 21 000 ECS93Y8BAA 10 200 460V 150 ECS93Y6CAA 21 000 ECS93Y8CAA 10 200 575V 150 ECS93Y6DAA 21 000 ECS93Y8DAA 10 200 240A 200V 75 24V DC ECS93Z6EAA 22 400 ECS93Z8EAA 11 500 S811T24N3S 230V 75 ECS93Z6BAA 22 400 ECS93Z8BAA 11 500 460V 200 ECS93Z6CAA 22 400 ECS93Z8CAA 11 500 575V 200 ECS93Z6DAA 22 400 ECS93Z8DAA 11 500 304A 200V 100 24V DC ECS9316EAA 29 400 ECS9318EAA 12 600 S811T30N3S 230V 100 ECS9316BAA 29 400 ECS9318BAA 12 600 460V 250 ECS9316CAA 29 400 ECS9318CAA 12 600 575V 300 ECS9316DAA 29 400 ECS9318DAA 12 600 Frame Size 290 mm 360A 200V 125 24V DC ECS9326EAA ECS9328EAA 15 200 S811V36N3S 230V 150 ECS9326BAA ECS9328BAA 15 200 460V 300 ECS9326CAA ECS9328CAA 15 200 575V 350 ECS9326DAA ECS9328DAA 15 200 420A 200V 150 24V DC ECS9336EAA ECS9338EAA 17 500 S811V42N3S 230V 175 ECS9336BAA ECS9338BAA 17 500 460V 350 ECS9336CAA ECS9338CAA 17 500 575V 450 ECS9336DAA ECS9338DAA 17 500 500A 200
38. S9506CAF 9 600 ECS9508CAF 5 950 575V 1 24VDC 3A ECS9506DAB 9 600 ECS9508DAB 5 950 S811N37N3S 3 7A ECS9506DAC 9 600 ECS9508DAC 5 950 7 1 2 15A ECS9506DAD 9 600 ECS9508DAD 5 950 20 30A ECS9506DAE 9 600 ECS9508DAE 5 950 30 50A ECS9506DAF 9 600 ECS9508DAF 5 950 66A 200V 10 24VDC 50A ECS95S6EAF 11 000 ECS95S8EAF 7 100 S811N66N3S 20 100A ECS95S6EAG 11 000 ECS95S8EAG 7 100 230V 15 24VDC 50A ECS95S6BAF 71 000 ECS95S8BAF 7 100 S811N66N3S 20 100A ECS95S6BAG 11 000 ECS95S8BAG 7 100 460V 50 24VDC___ 100A ECS95S6CAG 11 000 ECS95S8CAG 7 100 S811N66N3S 575V 40 24VDC 50A ECS95S6DAF 11 000 ECS95S8DAF 7 100 S811N66N3S 60 100A ECS95S6DAG 11 000 ECS95S8DAG 7 100 Frame Size 110 mm 105A 200V 25 24V DC 100A ECS95V6EAG 15 600 ECS95V8EAG 9 500 S811R10N3S 30 150A ECS95V6EAH 15 600 ECS95V8EAH 9 500 230V 30 24V DC 100A ECS95V6BAG 15 600 ECS95V8BAG 9 500 S811R10N3S 40 150A ECS95V6BAH 15 600 ECS95V8BAH 9 500 460V 60 24V DC 100A ECS95V6CAG 15 600 ECS95V8CAG 9 500 S811R10N3S 75 150A ECS95V6CAH 15 600 ECS95V8CAH 9 500 575V 75 24V DC 100A ECS95V6DAG 15 600 ECS95V8DAG 9 500 S811R10N3S 100 150A ECS95V6DAH 15 600 ECS95V8DAH 9 500 135A 200V 40 24V DC 150A ECS95W6EAH 18 800 ECS95W8EAH 11 500 S811R13N3S 230V 50 150A ECS95W6BAH 18 800 ECS95W8BAH 11 500 460V 100 150A ECS95W6CAH 18 800 ECS95W8CAH 11 500 575V 125 15
39. V 150 24V DC ECS9346EAA ECS9348EAA 18 900 S811V50N3S 230V 200 ECS9346BAA ECS9348BAA 18 900 460V 400 ECS9346CAA ECS9348CAA 18 900 575V 500 ECS9346DAA ECS9348DAA 18 900 650A 200V 250 24V DC ECS9356EAA ECS9358EAA 21 300 S811V65N3S 230V 250 ECS9356BAA ECS9358BAA 21 300 460V 500 ECS9356CAA ECS9358CAA 21 300 575V 600 ECS9356DAA ECS9358DAA 21 300 720A 230V 300 24V DC ECS9366BAA ECS9368BAA 30 400 811V72N3S 460V 600 ECS9366CAA ECS9368CAA 30 400 575V 700 ECS9366DAA ECS9368DAA 30 400 850A 230V 350 24V DC ECS9376BAA ECS9378BAA 32 400 S811V85N3S 460V 700 ECS9376CAA ECS9378CAA 32 400 575V 900 ECS9376DAA ECS9378DAA 32 400 1000A 230V 400 24V DC ECS9386BAA ECS9388BAA 36 500 S811V10N3S 460V 800 ECS9386CAA ECS9388CAA 36 500 575V 1000 ECS9386DAA ECS9388DAA 36 500 AIl IT soft starters are furnished with 24V DC Based on 1 0 Service Factor For 1 15 consult coils and control power supplies For 24V DC Eaton separate control use Mod Code C35 and change the 8th digit to Q i e ECS93S1EAA becomes ECS93S1QAA C35 Standard duty horsepower ratings are for 300 ramp current 30 seconds ramp Consult Eaton time and 3 starts per hour Consult Eaton Options seatesscestaiivanevaeadaednees for other ratings Cover Control Dimensions Discount Symbol CA03902004E For more information visit www EatonElectrical com E T N Cu
40. V10N3L 23 870 690V Option 690V ratings are available on the T and V Frames by changing the 8th digit in the Catalog Number to V Table 7 690V Option Frame Max Catalog Price amp Size Current Number U S az N 37 811N37P3S 3 060 ee 66 811N66P3S 4 085 R 105 811R10P3S 5 550 135 811R13P3S 6 430 T 180 811T18P3S 6 770 240 811T24P3S 7 110 304 811T30P3S 7 470 V 360 811V36P3S 8 550 420 811V42P3S 9 460 500 811V50P3S 10 490 650 811V65P3S 11 680 720 811V72P3S 13 220 850 811V85P3S 15 770 1000 811V10P3S 24 620 Accessories Surge Suppressors The surge suppressor can mount on either the line or load side of the IT Soft Starter It is designed to clip the line voltage or load side induced Surge Suppressor Mounted on a 200 mm Device Frame Max Catalog Price voltage Size Current Number U S Table 9 Surge Suppressors T 180 811T18V3L 6 080 240 S811T24V3L 6 440 Description Catalog Price 304 S811T30V3L 6 810 Number U S V 360 811V36V3L 7 850 600V MOV for 65 mm EMS38 172 420 811V42V3L 8 780 and 110 mm units 500 811V50V3L 9 810 600V MOV for 200mm EMS39 172 650 811V65V3L 10 980 and 290 mm units 720 811V72V3L 12 540 690V MOV for 200mm EMS41 200 850 811V85V3L 15 080 and 290 mm units CA03902004E Discount Symbol 0005 1CD1 For more information visit www Eato
41. begins with the control package which features 24V DC con trol onboard Digital Signal Processor DSP and use of a low impedance run contactor all of which contribute to the IT Soft Starter s safety advanced func tionality and compact size Designed to control acceleration and deceleration of three phase motors products are available from 37 to 1000 amps and are suitable for mounting in a variety of enclosures including Type 1 12 3R 4 4X and 7 9 m Built in overload protection a Adjustable trip class 5 10 20 30 a 30 100 FLA adjustment Q Selectable phase loss protection m Selectable current limit or ramp start m Adjustable ramp times Q 0 180 seconds standard a Extended ramps available m Adjustable torque control m Adjustable kick start control m Soft Stop control a 0 60 seconds standard Q Extended times available m Built in low impedance contactor m Six SCR Control in all units m Selectable phase reversal protection m Digital interface module CA03902004E Reduced Voltage Motor Starters Solid State Starters Enclosed Type S811 Intelligent Technologies T Soft Starters Features and Benefits m Mechanical stress on system a Reduced wear on belts gears chains clutches shafts and bear ings You can get up to 2 6 times the life on standard belts by switching to a soft starter Q Elimination of water hammer in pumping applications extends component life and helps limit leakage in system
42. e device in coordination with the S811 is required in branch motor circuits by most electrical codes Short circuit coordination ratings with both fuses and Cutler Hammer molded case cir cuit breakers are available providing customers with design flexibility The 811 has short circuit coordination ratings as an open component an enclosed starter and in a motor control center Jam Excessive current and torque up to locked rotor levels can occur in a jam condition The condition can result in stress and damage to the motor load mechanical system and the electrical distribution system Jam protection prevents the stress and damage from a jam during normal run After the motor is started a current greater than 300 FLA setting will cause the starter to trip on a jam fault Stall Excessive current and torque up to locked rotor levels can occur in a stall condition The condition can lead to an overload trip and result in stress and damage to the motor load mechani cal system and the electrical distribu tion system Stall protection prevents stress and damage to a motor that has not come up to speed or stalled after the soft start time The S811 will trip to protect the system in the event that the motor did not get to the rated speed in the defined soft start period A current greater than 200 FLA at the end of the soft start period will cause the starter to trip on a stall fault Pole Over Temperature High ambie
43. e motor or electrical distribution system Voltage can be used to moni tor electrical distribution system per formance Warnings alarms and system actions to low or high voltage conditions can be implemented Percent Thermal Memory Provides the real time calculated ther mal memory value The S811 calcu lates thermal memory value A 100 value represents the maximum safe temperature of the motor When the thermal memory value reaches 100 an overload trip will occur removing power to the motor The thermal memory value can be of great use in determining an impending overload trip condition Alarms can be implemented in the process monitor ing system warning of an impending trip before a trip occurs halting the process Costly system downtime can be avoided CA03902004E Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies T Soft Starters DC Control Voltage Monitors level of the 24V DC control voltage Fluctuations in control voltage can cause component malfunction and failure System control voltage data can be used to implement warnings alarms and system actions to low or high voltage conditions Pole Temperature Increases in pole temperature are caused by increases in ambient tem perature start stop times and start duty cycles Changes in pole tempera tures represent a change in system operating conditions Identifying unexpected operating conditions or
44. eel as indicated by becomes ECS94S1QAD C35 the seventh digit 4 Example ECS94S4EAD Standard duty horsepower ratings are To order Type 4X 316 Grade Stainless Steel Options Page 15 for 300 ramp current 30 seconds ramp change that digit to 9 To order Type 4 c c tr al a a ee P 16 time and 3 starts per hour Consult Eaton Painted Steel change that digit to 3 To OVET SOMITO gea eaat dadaake age for other ratings order Nonmetallic change that digit to 5 Dimensions s0seaes Page 24 Consult Eaton Discount Symbol 008 1CD1C For more information visit www EatonElectrical com CA03902004E E T N Cutler Hdammer Reduced Voltage Motor Starters Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters January 2005 Combination with Breaker Table 26 Class ECS95 811 T Soft Starter Enclosures Type 1 3R and 4X Amps_ Motor hp Coil Circuit Type 1 Type 3R Type 4X Component Voltage Voltage Breaker Soft Starter Type Open 1 0 Catalog Price Catalog Price Catalog Price Catalog S F Number U S Number U S Number U S Number Frame Size 65 mm 37A 200V 1 2 24VDC 3A ECS95Q1EAB 4 850 ECS9502EAB 5 950 ECS9504EAB 7 440 S811N37N3S 1 7A ECS95Q1EAC 4 850 ECS9502EAC 5 950 ECS95Q04EAC 7 440 3 15A ECS95Q1EAD 4 850 ECS9502EAD 5 950 ECS9504EAD 7 440 7 1 2 30A ECS95Q1EAE 4 850 ECS9502EAE 5 950
45. epower ratings are To order Type 4X 316 Grade Stainless Steel OPUONS eian aaua iA for 300 ramp current 30 seconds ramp change that digit to 9 To order Type 4 Cover Control time and 3 starts per hour Consult Eaton Painted Steel change that digit to 3 To Dimensions for other ratings order Nonmetallic change that digit to 5 Discount Symbol CA03902004E For more information visit www EatonElectrical com 18 Reduced Voltage Motor Starters Solid State Starters E T N Cutler Hammer January 2005 Enclosed Type S811 Intelligent Technologies T Soft Starters Table 23 Class ECS93 811 T Soft Starter Enclosures Type 7 9 and 12 Amps Motor hp Coil Type 7 9 Type 12 Component Soft Voltage Voltage Starter Open Catalog Price Catalog Price Catalog Number U S Number U S Number Frame Size 65 mm 37A 200V 10 24V DC ECS93Q6EAA 6 800 ECS93Q8EAA 3 100 S811N37N3S 230V 10 ECS9306BAA 6 800 ECS9308BAA 3 100 460V 25 ECS9306CAA 6 800 ECS9308CAA 3 100 575V 30 ECS9306DAA 6 800 ECS9308DAA 3 100 66A 200V 20 24V DC ECS93S6EAA 8 600 ECS93S8EAA 5 000 S811N66N3S 230V 20 ECS93S6BAA 8 600 ECS93S8BAA 5 000 460V 50 ECS93S6CAA 8 600 ECS93S8CAA 5 000 575V 60 ECS93S6DAA 8 600 ECS93S8DAA 5 000 Frame Size 110 mm 105A 200V 30 24V DC ECS93V6EAA 13 020 ECS93V8EAA 7 000 S811R10N3S 230V 40 EC
46. ilable in either starting mode The soft stop option allows for a ramp stop time that is longer than the coast to stop time The pump control option provides a smooth transition for starting and stopping a motor and eliminating the water hammer effect that can damage pipes valves and pumps The S811 offers an impressive array of advanced protective features Not only are the protective features selectable but many offer variable settings allow ing the user to fine tune the starter to meet specific system requirements The S811 has an easy to use Digital Interface Module DIM that allows the user to configure the device and to read system parameters The DIM includes an LCD display and keypad to scroll through the various menus The DIM allows the user to modify control parameters enable or disable protec tions set communication variables monitor system parameters such as line voltages and currents and access the fault queue ONLN SS OXFDO1 H STOP Monitoring gogo Q00 ESC Figure 1 Digital Interface Module DIM The DIM can be removed from the S811 and remote mounted Kits are available to door mount the DIM enabling users to safely configure commission monitor and trouble shoot the system at the electrical panel without opening the enclosure door The 811 has built in communications capabilities through Cutler Hammer QC Quick Connect Port The OCPort enables the soft starter to be c
47. ircuit Type 1 Type 3R Type 4X Component Voltage Voltage Breaker Soft Starter Type Open 1 0 Catalog Price Catalog Price Catalog Price Catalog S F Number U S Number U S Number U S Number Frame Size 290 mm 360A 200V 125 24V DC HMCP 600A ECS9521EAL 19 400 ECS9522EAL 21 300 ECS9524EAL 26 600 S811V36N3S 230V 150 HMCP 600A ECS9521BAL 19 400 ECS9522BAL 21 300 ECS9524BAL 26 600 460V 300 HMCP 600A ECS9521CAL 19 400 ECS9522CAL 21 300 ECS9524CAL 26 600 575V 350 HMCP 600A ECS9521DAL 19 400 ECS9522DAL 21 300 ECS9524DAL 26 600 420A 200V 150 24V DC HMCP 600A ECS9531EAL 21 100 ECS9532EAL 24 600 ECS9534EAL 30 200 S811V42N3S 230V 150 HMCP 600A ECS9531BAL 21 100 ECS9532BAL 24 600 ECS9534BAL 30 200 460V 350 HMCP 600A ECS9531CAL 21 100 ECS9532CAL 24 600 ECS9534CAL 30 200 575V 450 HMCP 600A ECS9531DAL 21 100 ECS9532DAL 24 600 ECS9534DAL 30 200 500A 200V 150 24V DC HMCP 600A ECS9541EAL 22 000 ECS9542EAL 27 200 ECS9544EAL 32 800 S811V50N3S 230V 200 HMCP 600A ECS9541BAL 22 000 ECS9542BAL 27 200 ECS9544BAL 32 800 460V 400 HMCP 600A ECS9541CAL 22 000 ECS9542CAL 27 200 ECS9544CAL 32 800 575V 500 HMCP 600A ECS9541DAL 22 000 ECS9542DAL 27 200 ECS9544DAL 32 800 650A 200V 200 24V DC HMCP 1200A ECS9551EAP 26 500 ECS9552EAP 33 700 ECS9554EAP 41 600 811V65N3S 230V 250 HMCP 1200A ECS9551BAP 26 500 ECS9552BAP 33 700 ECS9554BAP 41 600 460V 450 HMCP
48. le 19 Options Description Modification Code Pump Control Option P42 Extended Ramp R1 1g Reduced Voltage Motor Starters E T N Cutler Hammer Solid State Starters Enclosed Type S811 Intelligent Technologies T Soft Starters January 2005 Cover Control Factory Installed Pilot Devices To order factory installed pilot devices Flange Control Kits change the 9th character of the Catalog Number to the alpha shown in 4 4X and 12 enclosed starters Knock the table below Example to order an outs are provided on the Type 1 flange ECS90J4CAA with START STOP Type 3R 4 4X and 12 have pushbuttons and a red pilot light prepunched holes with removable change the A to a C i e ECS90J4CCA hole plugs For on the job conversion of Type 1 3R Table 20 Non reversing Pilot Devices Description Factory Installed Field Description Factory Installed Field Flange Control Installation Kits Flange Control Installation Kits Position Adder Catalog Price Position Adder Catalog Price 9 Alpha U S Number U S 9Alpha U S Number U S No Cover Mounted Pilot Devices A START Pushbutton L 180 00 C400T3 44 75 START STOP Pushbuttons B 180 00 C400T1 65 00
49. m V Frame 10 8576 meee Marken a 290 mm T Frame 10 8577 m CSA Certified 3211 06 m CSA Elevator 2411 01 Technical Data Table 18 Specifications IT Soft Starter Soft Starter s811 s811 s811 s81 ES E E E ie E E E Z EE Partial Catalog Number N37 N66 R10 R13 T18 T24 T30 v36 Vv42 vs0 ve5 v72 vs5 v10 Max Current Capacity 37 66 105 135 1s0 240 304 360 420 500 650 720 850 1000 FLA Range 11 37 20 66 32 a42 56 75 95 112 131 156 203 225 265 320 105 135 180 240 304 360 420 500 650 720 580 1000 Dimensions Width in Inches mm 2 66 67 6 4 42 112 2 7 67 194 8 11 05 280 6 Height in Inches mm 7 38 187 4 7 92 201 2 12 71 322 9 16 57 420 8 Depth in Inches mm 6 48 164 5 6 64 168 7 6 39 162 4 7 35 186 6 Weight in Ibs kg 5 8 2 6 10 5 4 8 48 21 8 with lugs 41 18 6 without lugs 103 46 8 with lugs 91 41 4 without lugs General Information Bypass Mechanical Lifespan 10M Insulating Voltage Ui 660V Ramp Time Range 5 180 Seconds 5 360 Seconds Extended Ramp Resistance to Vibration 3g Resistance to Shock 15g Electrical Information Operating Voltage 200 600V Operating Frequency 47 63 Hz Overload Setting 30 100 Trip Class 5 10 20 amp 30 Cabling Capacity IEC 947 Number of Conductors 1 1 1or2 2 4o0r6 Wire Sizes 14 2 14 4 0 4 AWG to 500 MCM 2 0 to
50. nElectrical com 10 Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters Lug Kits The 200 mm and 290 mm soft starters do not include lugs The 200 mm and 290 mm soft starters each have different lug options based on your wiring needs Each lug kit contains three lugs which can be mounted on either the load or line side PN waa apo Za ia eS A e le 2 Lug Kits EML23 Table 10 Lug Kits Frame Designation Frame Size Description Catalog Number U S Price 2 cable connections 4 AWG to 1 0 cable 1 cable connection 4 0 to 500 MCM cable 2 cable connections 4 0 to 500 MCM cable 1 cable connection 2 0 to 300 MCM cable 2 cable connections 2 0 to 300 MCM cable EML22 EML23 EML24 EML25 EML26 2 cable connections 4 0 to 500 MCM cable 4 cable connections 4 0 to 500 MCM cable 6 cable connections 4 0 to 500 MCM cable 4 cable connections 2 0 to 300 MCM cable The EML33 does not have a CSA Listing Lug Cover Kits Replacement covers for the T and V frame are available in case of damage to the existing covers Table 11 Lug Cover Kits Description Catalog Price Number U S Lug Cover T Frame EML27 70 50 Lug Cover V Frame EML34 87 50 Digital Interface Module The Digital Interface Module DIM is available as a replacement part Table 12
51. nt temperatures extended ramp times and high duty cycle condi tions may cause the S811 power pole conductors to reach a temperature that exceeds their thermal rating The S811 is equipped with sensors that monitor the temperature of the power poles Over temperature protection occurs if the device s thermal capacity is exceeded The soft starter will trip in over temperature conditions prevent ing device failure Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters The device pole temperature value can be monitored through the DIM or the communications network This feature can be of use in determining an impending over temperature trip condition Alarms can be implemented in the process monitoring system warning of an impending trip before a trip occurs halting the process Costly system shutdown can be avoided Phase Loss Loss of a phase can cause a significant increase in the current drawn in the remaining two phases Phase loss can lead to motor damage before an even tual overload trip occurs Phase loss is typically an indication of a failure in the electrical distribution system The 811 will detect a phase loss and trip if any phase current drops below a preset value The phase loss trip level is adjustable from 0 to 100 of the average of the other two phase levels with an adjustable trip delay of 0 1 to 60 seconds Phase Imbalance Phase c
52. on nected to a variety of networks including DeviceNet and EtherNet For more information visit www EatonElectrical com E T N Cutler Hammer January 2005 Modbus The advantage of OCPort is that multiple control components can be connected to one Cutler Hammer gateway The gateway concentrates data from the devices into a single node Configuration is simple a single press the gateway s Auto Configuration button sets the system up for default operation This automat ically configures the I O assemblies to the OCPort system devices The data from these devices are then assembled into a single input and output messages The S811 communication parameters can be configured with the DIM or through the network using CH Studio Component Manager Advanced communication configuration settings provide the system integrator with powerful tools to facilitate system optimization Features and Benefits m The DIM Digital Interface Module provides an intuitive easy to use human interface with powerful con figuration capabilities to maximize system performance m Door or device mounted DIM enables users to safely configure commission monitor and trouble shoot the system at the electrical panel without opening the enclo sure door mg System operating parameters can be monitored enterprise wide through a communications network Increase uptime by providing data for process management and preventive diagnostics
53. rage of the three phase RMS line currents in amps accurate to within 2 Current data can be used to indicate a need for maintenance Increased currents in a fixed load application can indicate a reduction in system efficiencies and performance signifying system maintenance is due Average Pole Current Provides the average of the three phase RMS pole currents in amps accurate to within 2 The pole current is the current through the soft starter The line and pole current will be identical in in line applications and will differ in inside the delta applications CA03902004E E T N Cutler Hammer January 2005 Average line current as a FLA Provides the average RMS line current as a percentage of the S811 FLA setting Three Phase Line Currents Provides three RMS phase line cur rents in amps accurate to within 2 Imbalances or changes in the relative phase current to one another can indi cate anomalies in the motor or electri cal distribution system Three Phase Pole Currents Provides three RMS phase pole cur rents in amps accurate to within 2 The pole current is the current through the soft starter The line and pole current will be identical in in line applications and will differ in inside the delta applications Three Phase Line Voltages Provides the individual RMS three phase line voltages Imbalances or changes in the relative phase voltage to one another can indicate anomalies in th
54. s pilates 5 91 150 0 gt Slots Figure 8 T Frame 200 mm 811 Approximate Dimensions in Inches mm CA03902004E For more information visit www EatonElectrical com q4 Reduced Voltage Motor Starters E T N Cutler Hammer Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters January 2005 7 35 186 6 A A 15 63 397 0 Mounting Holes 15 16 16 57 385 0 Slots 420 8 o 10000A 0000n g0 O0 AE arn AME gt CHO o g o KW 2 ITITI OOO k a Po in i t y Nil I 27 6 8 26 6 5 Dia h i 280 6 gt yp e 3 74 yp 4 Places 95 0 4 Places Figure 9 V Frame 290 mm S811 Approximate Dimensions in Inches mm For more information visit www EatonElectrical com CA03902004E E T N Cutler Hammer January 2005 811 Enclosed Soft Starters Enclosed 40 hp Soft Starter Product Description Eaton s revolutionary design for soft starters is shown in the S811 soft starter products which are members of the Cutler Hammer Intelligent Tech nologies IT family of products These Reduced Voltage Soft Starters are the most compact multi functional easy to install products on the market Their superiority
55. sing Operating Position Any Pollution degree IEC947 1 3 Impulse withstand Voltage 6000V IEC947 4 1 Dimensions 6 48 164 5 2 66 67 6 O 7 38 187 4 U A E 5 5 Typ 4 Places Figure 6 N Frame 65 mm 811 Approximate Dimensions in Inches mm For more information visit www EatonElectrical com CA03902004E E T N Cutler Hammer Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters January 2005 A 7 44 7 92 189 0 1 2 T ki k 27 es 4 Pios Figure 7 R Frame 110 mm 811 Approximate Dimensions in Inches mm 7 67 6 39 194 8 162 4 T gt o nj G Es 12 21 299 0 322 9 ppu Ea 5 40 137 2 ee I L I 2 95 g iF gt 75 0 Slots Typ Slot
56. tler Hammer January 2005 Combination with Fusible Disconnect Table 24 Class ECS94 811 T Soft Starter Enclosures Type 1 and 3R Reduced Voltage Motor Starters Solid State Starters Enclosed Type 811 Intelligent Technologies T Soft Starters Motor Voltage Coil Voltage Switch Rating Amps hp Type 1 Type 3R Component Soft Starter Open Catalog Price Catalog Price Catalog Number U S Number U S Number Frame Size 65 mm 37A 200V 3 24V DC 30A ECS9401EAB 4 590 ECS9402EAB 5 300 S811N37N3S 10 60A ECS9401EAD 4 590 ECS9402EAD 5 300 230V 7 1 2 30A ECS9401BAB 4 590 ECS9402BAB 5 300 S811N37N3S 10 60A ECS9401BAD 4 590 ECS9402BAD 5 300 460V 15 30A ECS9401CAC 4 590 ECS9402CAC 5 300 S811N37N3S 25 60A ECS9401CAE 4 590 ECS9402CAE 5 300 575V 20 30A ECS9401DAC 4 590 ECS9402DAC 5 300 S811N37N3S 30 60A ECS9401DAE 4 590 ECS9402DAE 5 300 66A 200V 10 24V DC 60A ECS94S1EAD 5 600 ECS94S2EAD 6 900 S811N66N3S 20 100A ECS94S1EAF 5 600 ECS94S2EAF 6 900 230V 15 60A ECS94S1BAD 5 600 ECS94S2BAD 6 900 S811N66N3S 20 100A ECS94S1BAF 5 600 ECS94S2BAF 6 900 460V 50 100A ECS94S1CAG 5 600 ECS94S2CAG 6 900 S811N66N3S 575V 40 60A ECS94S1DAE 5 600 ECS94S2DAE 6 900 S811N66N3S 60 100A ECS94S1DAG 5 600 ECS94S2DAG 6 900 Frame Size 110 mm 105A 200V 3
57. to 5g and shock in up to 40g The soft starter is mounted onto the vibration plate prior to installation in the panel Table 15 Vibration Plates Description Catalog Price Number U S Vibration Plate N Frame EMM14N 141 00 Vibration Plate R Frame EMM14R 152 00 Vibration Plate T Frame EMM14T 175 00 Vibration Plate V Frame EMM14V 204 00 Power Supplies 24V DC Power Supply which can be used with the S811 SSRV or as a stand alone device Table 16 Power Supplies Description Catalog Number Price U S PSS55A 251 00 115V AC Input 24V DC Output 230V AC Input 24V DC Output 380 480V AC Input 24V DC Output PSS55B 251 00 PSS55C 300 00 DIN Rail Power Supply Mounting Kit 35 mm Table 17 DIN Rail Mounting Kit Description Catalog Price Number U S DIN Rail Mounting PSSDIN 24 00 Kit 35 mm Discount Symbol 0008 1CD1 CA03902004E E T N Cutler Hammer January 2005 Standards and Certifications m IEC 60947 4 2 m EN 60947 4 2 m UL Listed NMFT Frame N37 to V85 Reduced Voltage Motor Starters Solid State Starters Open Type S811 Intelligent Technologies IT Soft Starters Instructional Leaflets m Instruction Manual MN03902002E m Outline Drawings Q 65 mm N Frame 10 8574 Q 110 mm R Frame 10 8575 m UL Recognized NMFT2 Frame V10 u 200 m
58. urrent or voltage imbalance can cause a significant increase in the current drawn in the remaining two phases Phase imbalance can lead to motor damage before an eventual overload trip Phase imbalance is typically an indication of a failure in the electrical distribution system or the motor The S811 will detect both current and voltage phase imbalances and trip if any phase becomes imbal anced as compared to the average of the other two phases The phase current imbalance trip level is adjustable from 0 to 100 of the average of the current in the other two phases with an adjustable trip delay of 0 1 to 60 seconds The phase voltage imbalance trip level is adjustable from 0 to 100 of the average of the voltage in the other two phases with an adjustable trip delay of 0 1 to 60 seconds Reset Mode The S811 can be set up for automatic or manual reset on trip The manual reset mode requires the operator to physically press the RESET button located on the soft starter The over load can be manually reset through the DIM or through the communica tions network The overload can also be electrically reset by energizing a 24V DC input on the control terminal block The automatic reset mode allows the soft starter to be automatically reset as soon as the trip condition is no longer present With the automatic reset mode after the fault is no longer present the motor will be restarted as soon as a valid start signal is present