Contents
1. 33 oz NelbilerrEG550 uuu s dun a 33 0 2 NeIbiler EC2202u urna aus a hu a ha aise kuusascus 34 8 2 Temperature Se S0ruu un uu l u ua ete 35 OF TANK DCMS OR te r u u e eat ed ened 35 Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Preface 3 36 1 Preface 1 1 About This Document This manual describes how to install the Netbiter set up a basic configuration EasyConnect Starter Kit and For additional related documentation and file downloads please visit the Net biter support website at www netbiter com support 1 2 Related Documents Related documents Document Author Netbiter Argos Administration Manual HMS Netbiter EasyConnect Gateway Installation Guides HMS Netbiter EasyConnect User Manual HMS 1 3 Document history Summary of recent changes version 2 20 to 3 00 Change Where section no New document layout Footnote regarding stub antenna 2 1 Revision list Version Date Author Description 1 00 March 2014 SDa Initial release 2 00 May 2015 ThN Major update 3 00 August 2015 ThN Minor update new layout Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Preface 4 36 1 4 Conventions Unordered bulleted lists are used for e Itemized information e Instructions that can be carried out in any order Ordered numbered or alphabetized lists are used
2. 14 4 1 Installing the SIM Card 14 4 2 Installing the Antenna 15 4 3 Connecting the Power Supply 15 4 4 Connecting the Temperature Sensor 16 5 LED Status Indicators T 17 Oil EGC 5501ED lndie8lo Su uuu u ua anatata es 17 9 2 EC220 ED INACIO uuu y Gade ence tina ides Ar Ne 19 Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Table of Contents 6 Adding the Netbiter to Netbiter Argos ssssssnnnnnnnnnnnnnnne 20 6 L ADout Netbiler A g062u 2 uu u uu INR oe elt 20 6 2 Creating a Netbiter Argos Account 21 6 2 1 Password recommendations 22 6 3 Activating a Netbiter EC350 23 6 4 Activating a Netbiter EC220 24 7 Configuring the Netbiter 26 7 1 Temperature Sensor z uuu L u uu UU eee eee 26 TZ Tank SENSO nansa aa oases Re Rnb 28 7 3 Geographical LOCATION seni u te ua a eddie 31 4 Viewing the Project 32 8 Technical Data
3. Mounting DIN rail EN 50022 or wall mounting Dimensions H x W x D 25 x 115 x 92 mm Operating temperature 30 C to 65 C Storage temperature 40 C to 85 C Humidity range 5 95 RH non condensing Power supply 9 24 VDC 2 W Power consumption typical 2W IP rating IP20 Certifications CE ROHS cULus FCC IC PTCRB Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Technical Data 35 36 8 3 Temperature Sensor Type Pt100 Dimensions H x W x D 25 x 84 5 x 84 5 mm Measuring range 50 C to 50 C Storage temperature 35 C to 70 C IP rating IP30 Certifications CE 8 4 Tank Sensor Type Ultrasonic sensor Measuring range 80 2000 mm Accuracy lt 1 5 Serial port RS485 Modbus isolated Connector type M12 Mounting Screws on top of tank Dimensions H x W x D 30 x 125 x 76 5 mm Operating temperature 15 C to 70 C Storage temperature 40 C to 85 C Power supply 12 30 VDC 0 6 W IP rating IP67 Certifications UL CE Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 R48 2015 08 11 16 45 UTC 2015 HMS Industrial Networks AB
4. Power 3G GPRS RS485 RS232 A B COM Rx T x GND 1 Insertthe SIM card carefully into the EC350 as shown in the figure Ob serve the position of the cut off corner and the contact surfaces When inserting the SIM card make sure it does not accidentally slip behind the SIM card holder 2 Push the SIM card firmly down into the holder until it clicks into place 3 Connect an antenna to the 3G GPRS SMA antenna connector on the front panel of the EC350 Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC350 Starter Kit 10 36 3 2 Ethernet Network G Ignore this step if you are only going to connect via mobile network mcd 1 Connect an Ethernet cable with an RJ 45 plug to the WAN port 2 Connect the other end to a network with Ethernet access Read Network Configuration and Security page 8 before attempting to connect to an Ethernet network 3 3 Connecting the Power Supply 1 Insert the 2 pin connector block into the Netbiter EC350 2 Connect the red wire to the connector 3 Connect the black wire to the connector Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC350 Starter Kit 11 36 3 4 Connecting the Temperature Sensor A Switch off or unplug the power supply before continuing 1 Open the sensor housing and connect the supplied wires to th
5. EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 LED Status Indicators 18 36 EC350 System Status default mode LED Indication Meaning RS485 RS232 Off Port not in use Red steady Port failure contact Netbiter support Green steady Port enabled in Netbiter Argos Uplink WAN Red steady Incorrect IP address settings e DHCP Check for a working DHCP server on the network e Static IP Check that the IP address gateway and DNS are correctly set Red flashing No connection to Netbiter Argos e Check your network settings e Check that port 443 is open in the firewall Green steady Connected to Netbiter Argos Modem Off Modem disabled Red steady Modem failure contact Netbiter support Red flashing SIM card failure e Check that the SIM card is correctly inserted and undamaged Orange steady PIN code is activated for the SIM card e Disable the PIN code on the SIM card Orange flashing APN Access Point Name missing This is normal when connecting the first time as APN has not yet been set APN settings are configured in Netbiter Argos and then uploaded to the EC350 Green flashing Searching for mobile network Green steady Connected to mobile network Gateway Off No power or unit is starting up Red steady Hardware failure contact Netbiter support Red flashing Application failure contact Netbiter support Green flashing Firmware update in progress G
6. Stub antenna is not included in the U S Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Before Installation 6 36 netbiter SIM card Netbiter SIM card UN ME E T netbiter argos Netbiter Argos Activation Details Netbiter is a complet that enables you to SYSTEM ID ACTIVATION CODE Netbiter Argos Activation Details The Netbiter EasyConnect Gateway cannot be activated without the System ID and Activation Code Keep the Netbiter Argos Activation Details safe for later reference Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Before Installation 7 36 Temperature Sensor Starter Kit Temperature sensor and wiring kit Tank Sensor Starter Kit L Tank sensor Tank sensor connection cable L Rubber gasket L Metal washer sand p Installation Guide itor netbiter Ultrasonic Tank Sensor Preparations L Tank Sensor Installation Guide Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Before Installation 8 36 2 2 2 2 1 2 2 2 Network Configuration and Security Ethernet Networks Before installing a Netbiter EC350 gateway on an Ethernet network make sure that you have the following information about the network environment Con tact your network administrator if in d
7. ccount Thn_test_220 25 System activation System ID 357973040909811 Activationcode L L a G __ se I have a Netbiter SIM card I have a custom or standard SIM card SIM card mobile number Product type EC220 B 2 Modbus product The firm Note that it might take several minutes before the unit will come online when activating 4 Click I have a Netbiter SIM card and enter the phone number for the SIM card o The phone number for the Netbiter SIM card is printed on the document the SIM card was attached to 5 Select EC220 as product type 6 Click on Activate You will now be redirected to the Management page Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Adding the Netbiter to Netbiter Argos 25 36 7 Onthe Management page click on Send Netbiter Argos will now send an SMS to the gateway to confirm the activation Please note that this may take several minutes Logged In Thomas Nilsson Account Thn_test_220 u 2 Status Configuration Templates Dashboards Map Firmware Mobile network Properties I have a Netbiter SIM card 1 have a custom or standard SIM card 5 2 SIM card mobile number Configuration SMS send in progress Note that this might take several minutes SEND SMS IN PROGRESS send 8 When the configuration SMS has been received the red star in the tab bar will change to green indicating that the gateway is
8. for instructions that must be carried out in sequence 1 First do this 2 Then open this dialog and a set this option b and then this one Bold typeface indicates interactible parts such as connectors and switches on the hardware or menus and buttons in a graphical user interface Monospaced text is used to indicate program code and other kinds of data input output such as configuration scripts This is a cross reference within this document About This Document page 3 This is an external link URL www netbiter com support O This is additional information which may facilitate installation and or operation ity and or damage to the equipment or to maintain network security A This instruction must be followed to avoid a risk of reduced functional Caution This instruction must be followed to avoid a risk of personal injury Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Before Installation 5 36 Before Installation 2 1 Starter Kit Contents Checklist Unpack the Starter Kit and check that all the items in the checklist are in cluded If an item is missing please contact Netbiter support Netbiter EasyConnect Starter Kit Contents Netbiter EasyConnect gateway Power supply DIN rail mounting kit USB cable Stub antenna Magnetic antenna with extension cable A L Connectors gt 1
9. S WCDMA FDD 800 850 900 1900 2100 MHZ Quad band GSM GPRS 850 900 1800 1900 MHz Ethernet 10 100 Mbit s Proxy types supported SOCKS authentication none username pwd Web authentication none basic Alarms Email SMS Relay outputs 1 max 24 V AC DC 1A Digital inputs 2 dry contact type Analog inputs Serial ports All 4 inputs with support for Vand mA 2 inputs with support for Pt100 RS232 RS485 Antenna connector mobile SMA female Antenna connector GPS SMA female active or passive USB interface Supported protocols Micro USB USB 2 0 Modbus RTU Mounting DIN rail EN 50022 or wall mounting Dimensions H x W x D 25 6 x 135 x 92 mm Operating temperature Storage temperature Humidity range Power supply 40 C to 65 C 45 C to 85 C 5 95 RH non condensing 12 48 VDC 6 W LPS Power consumption typical IP rating Certifications 4 5 W IP20 CE ROHS Telec JATE cULus FCC IC PTCRB RCM Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Technical Data 34 36 8 2 Netbiter EC220 Mobile communication Quad band GSM GPRS 850 900 1800 1900 MHz Alarms Email SMS Relay outputs 1 max 24 V AC DC 1A Digital inputs 2 Analog inputs 2 both with support for V mA Pt100 Serial ports Antenna connector Supported protocols RS232 RS485 SMA female Modbus RTU
10. anual Doc ID SP1706 Version 3 00 Adding the Netbiter to Netbiter Argos 20 36 Adding the Netbiter to Netbiter Argos About Netbiter Argos Before a Netbiter EasyConnect gateway can be used it must be registered and activated from a user account in Netbiter Argos Netbiter Argos is a web based communications centre for all your connected Netbiter EasyConnect gateways accessible from any Internet connected browser It is used for activating and configuring your Netbiter gateways and provides access to control functions logs and stored data and can be custom ized to fit your needs Presentation Management Contact Logout Logged In Thomas Nilsson Account Thn_test_220 2 e Netbiter EC350 Starterkit Overview Alarm Historical data Browse devices Map Information Digital Inputs Temperature Input AIN DI1 0 a 20 0 26 5 C Signal Quality Relay Output IE Temperature Value 16 Status Off Temperature Input AI1 31 days 7 days 24 hours M Temperature 1 2015 05 03 201 16 00 ur 05 03 2015 05 04 2015 05 04 2015 05 04 2015 05 04 20 00 00 00 04 00 08 00 12 00 N o Live values Name Value Alarms Source Alarm Time Severity Status Action Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Adding the Netbiter to Netbiter Argos 21 36 6 2 Creating a Netbiter Argos Account O To re
11. are not followed Static con trol precautions are required when handling the product Failure to ob serve this may cause damage to the product Copyright 2015 HMS Industrial Networks AB All rights reserved Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 This page intentionally left blank Table of Contents t ECAC Sn A 3 1 1 About This Document 3 1 2 Related Documents 3 1 8 IOCUMMEMEMISLONY ssa ua uu uen en Men tee eee 3 1 14 CoOnV niONSs uuu u u a tete 4 2 Before Installation nt ane 5 2 1 Starter Kit Contents Checklist 5 2 2 Network Configuration and Security 8 2 2 1 Ethernet NGIWONKS u u a ee ee trs 8 2 2 2 Mobile Networks 8 3 Installation Netbiter EC350 Starter Kit 9 3 1 Mobile NelWO K u uuu u u u uu u uu uu US Sus 9 3 2 Ethernet Network 10 3 3 Connecting the Power Supply 10 3 4 Connecting the Temperature Sensor 11 3 5 Connecting the Tank Sensor 12 4 Installation Netbiter EC220 Starter Kit
12. e terminals Push 2 Insert the 11 pin connector block into the connector slot on the EC350 m six YO Q Om eo a Q s D 1210 lt lt lt eA OA Z k 1 Analoq In DI Pulse In Relay Power 3 Connect one of the wires to the Analog In COM terminal and the other wire to the Analog In AI 1 terminal AARAAAAASAA m gt 3 LS SO Z lt lt FG05508 Analog In Di Pulse In Rela Power mM 48 V Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC350 Starter Kit 3 5 Netbiter EasyConnect Starter Kit User Manual Connecting the Tank Sensor 12 36 A Switch off or unplug the power supply before continuing For instructions on how to physically install the tank sensor please refer to the Netbiter Tank Sensor Installation Guide 1 Connect the plug end of the supplied cable to the tank sensor 2 Insert the 11 pin connector block into the large connector slot on the EC350 and a 3 pin connector block into the RS 485 slot 6233946052688 Doc ID SP1706 Version 3 00 Installation Netbiter EC350 Starter Kit 13 36 3 Connect the black wire to the RS485 A terminal Blue Brown AGE Ssausddaide r P Analog In Di Pulsein Relay Foner a lt netbiter San ec350 amp UplinkWAN d gt FA III a wr Black White 4 Connect the white w
13. g viewing live values and alarm management of the devices connected to the EC product J Use system for Remote Access Primary usage will be remote access and use of the EC product for access to connected devices via own software tools Note that it might take several minutes before the unit will come online when activating activate 4 Select Use system for View and Control Remote Access 5 Click on Activate You will now be redirected to the Management page Management Contact Logout Online since 2015 04 13 16 42 42 Logged In Thomas Nilsson Account Thn_test_01 se Be Status Configuration Templates Dashboards Map Firmware Mobile network Properties System ID 003011FBFEE2 Online History A green star in the tab bar indicates when the gateway is online O If using a mobile connection with a SIM card not supplied by HMS please refer to the Netbiter EasyConnect User Manual for instructions Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Adding the Netbiter to Netbiter Argos 24 36 6 4 Activating a Netbiter EC220 1 Make sure that the Netbiter is operating and connected to the network See LED Status Indicators page 17 2 Log in to the account at www netbiter net 3 On the System activation tab your System ID and Activation code should already be filled in If not enter them now Logout G ir homas Nilsson
14. gateway Virtual EC300 series Netbiter EasyConnect EC300 series edit GPS Virtual GPS Netbiter GPS edit 2 Select Use configuration from a profile and in the Device type drop down menu select Virtual ECxxx series This will load the associated pre configured device profile Add device 1 3 Set device type Use configuration from a template Use configuration from a profile Device type Virtual EC300 series Device profile Netbiter EC300 Starter kit Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Configuring the Netbiter 27 36 3 Click Next in this and the following dialog then click Save to save the new device configuration in Netbiter Argos Add device cancel 2 3 Set device properties use device name from template Device name Netbiter EC300 Starter kit wt Add device cancel 3 3 Gateway settings Remember to configure the gateway settings sa 4 Finally click oon Synchronize configuration Netbiter Argos will now up load the configuration to the Netbiter gateway which will automatically reboot When the process has completed data from the gateway will be available in Netbiter Argos Zt Status Configuration Templates Dashboards Map Firmware Mobile network Properties Last configuration update 2015 05 06 17 02 50 Last synchronization Never synchronized 3g Synchronize configuration Synchronize configuration 10 sending co
15. gister a Netbiter Argos account you will need the System ID and Ac tivation Code supplied with the Netbiter If the Activation Code has been lost please contact Netbiter support 1 Go to the Netbiter Argos website at www netbiter net 2 Click on Create an account and enter the required information in the registration form See also Password recommendations page 22 mr Create a new account Information about your product System ID Activation Code netbiter argos Information about your account Account name Password Repeat Password Your user information First Name Last Name Company Country Select B Phone E mail Confirm E mail Accept the terms and conditions 3 Click on the Accept the terms and conditions link at the bottom of the registration form If you approve of the terms and conditions for using Netbiter Argos that are presented continue to the next step Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Adding the Netbiter to Netbiter Argos 22 36 4 Close the Terms and Conditions popup window tick the checkbox and click on Register An email containing an activation link will be sent to the email address that you provided W Accept the terms and conditions 5 Click on the activation link in the email sent to you by Netbiter Argos When the account has been activated you will see a confirmation screen Your account is
16. ion then click on the location to enter the coordinates The position can also be set by entering the coordinates in WGS84 format If a GPS receiver is connected to the gateway EC350 only and enabled in Netbiter Argos the coordinates can be retrieved by clicking on GPS See the documentation for Netbiter Argos for further information 3 Click Save to store the coordinates Doc ID SP1706 Version 3 00 Netbiter EasyConnect Starter Kit User Manual Configuring the Netbiter 32 36 7 4 Viewing the Project Now that you have added your first field system to your first project it can be viewed in Netbiter Argos Select the Presentation tab to access the new project Presentation Management Contact Logout Logged In Thomas Nilsson Account Thn_test_01 2 Netbiter EC350 Starterkit Overview Alarm Historical data Browse devices Map Information refresh Netbiter EC350 Starterkit Digital Inputs Temperature Input AN DI1 0 aa 20 0 oo 26 5 C Signal Quality Relay Output Temperature Internal d oe OFF Value 15 Status 0 For more information about how to proceed with configuring your projects and devices see the full documentation for Netbiter Argos Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Technical Data 33 36 8 Technical Data 8 1 Netbiter EC350 Mobile communication 5 band 3G UMT
17. ire to the RS485 B terminal 5 Connect the brown wire to the terminal 6 Connect the blue wire to the terminal If using the same power source to power both units make sure that it has the sufficient capacity The power supply included in the Netbiter EC350 Starter Kit is capable of powering both the tank sensor and the Netbiter EC350 See also Technical Data page 33 Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC220 Starter Kit 14 36 4 Installation Netbiter EC220 Starter Kit 4 1 Installing the SIM Card 1 Push the yellow button next to the SIM card holder and remove the hold er from the EC220 2 Place the SIM card into the holder Observe the correct position of the cut off corner and the contact surfaces 3 Insert the SIM card holder with the SIM card into the EC220 Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC220 Starter Kit 15 36 4 2 Installing the Antenna e Connect the stub antenna or external antenna to the SMA antenna con nector on the front panel of the EC220 4 3 Connecting the Power Supply 1 Connect the red wire to the Vdc terminal 2 Connect the black wire to the GND terminal Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC220 Starter Kit 16 36 4 4 Connecting the Te
18. lose the web page until synchronization is complete See the full documentation for Netbiter Argos for further information Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 31 36 Configuring the Netbiter 7 3 Geographical Location The location of the Netbiter can be graphically represented on a map This fea ture is for presentation only and will not affect the function of the system 1 On the Management tab select Map rh empires 2 Map Satellite w Status Configuration Templates Dashboards Map Firmware Mobile network Properties mis A is a rm z v 2 O e Stuvaregatan Studentparken a Vindr Os a 4 DS Styrm 1ansgatan Foraldrakooperativet 4 l dhaken gt il a c 1 Ku Kri A B tsm j offers y i s Msgatan S D 9 en KE N 2 C3 p Jun g amp an lt Ima oj li Satan tog G I kI 2 z S a S S eo oy tapelgatan e y K 2 as g oe 2 we System location g E w _ Map data 2015 Google TermsofUse Report a map erro Latitude WGS 84 IN x 156 e 39 55 23 rs Longitude WGS 84 E v 12 si 48 32 Get position from GPS gps Enable GPS tracking on map enabled x Alarm radius 500 m clear tracking 2 Use the mousewheel or the slider in the map to zoom and click and drag to pan Center the map on the location of your installat
19. mperature Sensor A Switch off or unplug the power supply before continuing 1 Open the sensor housing and connect the supplied wires to the terminals Push D 2 Connect one of the wires to the AI A1 terminal and the other to the AI COM terminal on the EC220 Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 LED Status Indicators 17 36 LED Status Indicators EC350 LED Indicators All 6 LED indicators will light up while the gateway is starting up After the startup sequence has completed they will indicate system status Pressing and releasing the MODE button will temporarily change the func tion of the top 5 LED indicators to show the strength of the mobile network signal After 60 seconds the indicators will revert to showing system status Press and release MODE O O netbiter RS485 ec3 50 Rs232 D Uplink WAN Modem Gateway Power O Ke 3G GPRS CD a oe RS485 RS232 A B COM Rx Tx GND EC350 Signal Strength press and release MODE LED indication Meaning 1 red LED flashing 1 orange LED flashing Poor mobile network signal e Make sure the antenna is correctly installed and pointing upwards e Try a different antenna placement e Use an external antenna No unknown signal 1 green LED flashing Acceptable mobile network signal 2 5 green LEDs flashing Good to optimum mobile network signal Netbiter
20. netbiter USER MANUAL Netbiter EasyConnect Starter Kit Doc ID SP1706 Version 3 00 USB netbiter pszee ec350 Uplink WAN Modem Gateway 17 sah oad Connecting Devices HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN RAVENSBURG HMS Industrial Networks Mailing address Box 4126 300 04 Halmstad Sweden E mail info hms networks com Visiting address Stationsgatan 37 Halmstad Sweden Web www netbiter com Important User Information Liability Every care has been taken in the preparation of this manual Please inform HMS In dustrial Networks AB of any inaccuracies or omissions The data and illustrations found in this document are not binding We HMS Industrial Networks AB reserve the right to modify our products in line with our policy of continuous product development The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks AB HMS Industrial Net works AB assumes no responsibility for any errors that may appear in this document There are many applications of this product Those responsible for the use of this de vice must ensure that all the necessary steps have been taken to verify that the appli cations meet all performance and safety requirements including any applicable laws regulations codes and standards HMS Industrial Networks AB will under no circumstances as
21. nfig amp Synchronize of configuration in progress Do not hit back or close the browser until Device configuration Logging 2 Device MyFirstSystem gateway the process is completed nine checking ol GPS i update version info check version Netbiter EC350 Starter kit sending config Synchronization can take some time depending on the speed of your net work connection Do not close the web page until synchronization is complete See the Netbiter Argos Administration Manual for further information on how to use Netbiter Argos Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Configuring the Netbiter 28 36 7 2 Tank Sensor 1 Goto the Netbiter support website www netbiter com support and select File and document downloads Netbiter Accessories 2 Click on the link for Ultrasonic Tank Sensor Device Profile 3 You will now be automatically redirected back to Netbiter Argos Press Confirm to add the new device profile to the list of profiles in your Net biter Argos account Presentation Management Contact Logout Logged In Thomas Nilsson Account Thn_prod_350_01 2 Are you sure that the folowing profile should be added to this account Ultrasonic Tank Sensor v1L0 The use of this link will add a profile published from another Netbiter Argos account to your account 7 profile if you are sure of its source 4 On the Managemen
22. now activated and ready to use Login to your new account netbiter argos 2007 2014 All rights reserved Netbiter is a registered trademark of HMS Industrial Networks You can now log in to your new Netbiter Argos account using the username and password that you supplied in the registration form 6 2 1 Password recommendations Selecting a strong password is important to prevent unauthorized access The password you select for your Netbiter Argos account should e consist of at least 8 characters including upper and lower case letters nu merals and special characters e not contain personal user information e notbe the same as the username or the users email address e not be used on multiple sites Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Adding the Netbiter to Netbiter Argos 23 36 6 3 Activating a Netbiter EC350 1 Make sure that the Netbiter is operating and connected to the network See LED Status Indicators page 17 2 Log in to the account at www netbiter net 3 On the System activation tab your System ID and Activation code should already be filled in If not enter them now rs Logged In Thomas Nilsson Account Thn_test_01 System activation System ID Activation code Select primary usage for this system This can be changed later Use system for View amp Control Remote management Primary usage will be loggin
23. on in Netbiter Argos Device configuration Logging 2 Visualization 7 Alarms 4 Connected device profile Gateway settings Device Device type Settings Template Action MyFirstSystem gateway Virtual EC300 series Netbiter EasyConnect EC300 serie edit GPS Virtual GPS Netbiter GPS edit Ultrasonic Tank Sensor v1 0 Modbus Modbus slave 20 Ultrasonic Tank Sensor v1 0 pv1 0 edit remove Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Configuring the Netbiter 30 36 Finally click on Synchronize configuration Netbiter Argos will now up load the configuration to the Netbiter gateway which will automatically reboot When the process has completed data from the gateway will be available in Netbiter Argos Z w Status Configuration Templates Dashboards Map Firmware Mobile network Properties Last configuration update 2015 05 06 17 02 50 Last synchronization Never synchronized 3g Synchronize configuration Use this system for remote access Synchronize configuration OFF 0 sending config Device configuration Logging 2 Vis i Synchronize of configuration in progress Device Do not hit back or close the browser until Action MyFirstSystem gateway LEE 300 serie edit GPS edit check version Ultrasonic Tank Sensor v1 0 rc v1 0 pv1 0 dit rem Synchronization can take some time depending on the speed of your net work connection Do not c
24. online Logged In Thomas Nilsson Account Thn_test_220 w Status Configuration Templates Dashboards Map Firmware Mobile network Properties I have a Netbiter SIM card I have a custom or standard SIM card 3 d SIM card mobile number v Configuration SMS delivered Note it might take some minutes before the system comes online Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Configuring the Netbiter 26 36 7 Configuring the Netbiter Netbiter EasyConnect gateways are normally configured using device specific configuration sets called device profiles In the following chapter you will add a device profile in Netbiter Argos and then upload it to the gateway The procedure is slightly different depending on whether you are using a temperature sensor or a tank sensor 7 1 Temperature Sensor 1 On the Management page select Configuration and click on Add device Management Contact Logout ed In Thomas Nilsson Account Thn_dev_350_01 Ww Status Configuration Templates Dashboards Map Firmware Mobile network Properties Last configuration update 2015 05 06 15 19 14 Last synchronization Never synchronized 3g Synchronize configuration Use this system for remote access OFF Device configuration Logging 0 Visualization 0 Alarms 0 Connected device profile Gateway settings Device Device type Settings Template Action MyFirstSystem
25. oubt e Network addressing mode DHCP or static IP e IP address range netmask and default gateway if not using DHCP e Firewall restrictions and policies Netbiter EC350 communicates via port 443 This port must be open in the fire wall to allow communication with Netbiter Argos Q The gateway should only be installed in a network which is protected by a firewall Contact your network administrator if in doubt Mobile Networks The Netbiter EasyConnect Starter Kit is primarily intended to be used with the included Netbiter SIM card which is configured ready to use and with PIN code security disabled If you are using a SIM card which was not provided by HMS make sure be fore installing the Netbiter that you have the following information e The phone number for the SIM card e The APN Access Point Name for the mobile network e The username and password if required by the network operator Also make sure that PIN code security has been disabled for the SIM card number should always be stored safely N The details about your SIM card such as phone number and serial Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Installation Netbiter EC350 Starter Kit 9 36 3 Installation Netbiter EC350 Starter Kit 3 1 Mobile Network i Ignore this step if you are only going to connect via Ethernet netbiter RS485 ec3 5 O CD Rs232 uplink WAN Modem Gateway
26. reen steady Unit is operational Power Off No power Green steady Unit has power Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 LED Status Indicators 19 36 5 2 EC220 LED Indicators All 4 LED indicators will be lit while the gateway is starting up After the startup sequence has completed they will indicate system status netbiter EC220 LED Indicators LED Indication Power Status Running GSM Signal Meaning Power Off Green steady Status Off No power Unit has power Normal operation Red 1 flash SIM card not registered on HMS Home Network e Check that the SIM card is correctly inserted and undamaged and that PIN security is disabled Red 2 flashes Red 3 flashes Running Off Invalid network settings e Check that the APN Access Point Name has been set in Netbiter Argos No connection to Netbiter Argos e Check that the mobile network pro vider grants access to port 5222 Contact Netbiter support Green flashing Normal operation GSM Signal Off Green 1 flash Green 2 flashes Green 3 flashes Contact Netbiter support Poor mobile network signal e Make sure the antenna is correctly in stalled and pointing upwards e Try a different antenna placement e Use an external antenna Acceptable mobile network signal Good mobile network signal Netbiter EasyConnect Starter Kit User M
27. sume liability or responsi bility for any problems that may arise as a result from the use of undocumented fea tures timing or functional side effects found outside the documented scope of this product The effects caused by any direct or indirect use of such aspects of the prod uct are undefined and may include e g compatibility issues and stability issues The examples and illustrations in this document are included solely for illustrative pur poses Because of the many variables and requirements associated with any particu lar implementation HMS Industrial Networks AB cannot assume responsibility for actual use based on these examples and illustrations Intellectual Property Rights HMS Industrial Networks AB has intellectual property rights relating to technology embodied in the product described in this document These intellectual property rights may include patents and pending patent applications in the USA and other countries Trademark Acknowledgements Netbiter is a registered trademark of HMS Industrial Networks AB Java is a regis tered trademark of Oracle and or its affiliates All other trademarks are the property of their respective holders This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This product contains ESD Electrostatic Discharge sensitive parts that may be damaged if ESD control procedures
28. t page select Configuration and click on Add device Contact Logout Logged In Thomas Nilsson Account Thn_dev_350_01 2 Status Configuration Templates Dashboards Map Firmware Mobile network Properties Last configuration update Last synchronization Synchronize configuration 2015 05 06 15 19 14 Never synchronized 3 Use this system for remote access OFF Device configuration Logging 0 Visualization 0 Alarms 0 Connected device profile Gateway settings Device Device type Settings Template Action MyFirstSystem gateway Virtual EC300 series Netbiter EasyConnect EC300 series edit GPS Virtual GPS Netbiter GPS edit Netbiter EasyConnect Starter Kit User Manual Doc ID SP1706 Version 3 00 Configuring the Netbiter 29 36 5 Select Use configuration from a profile and for Device type select Mod bus for Device profile select Ultrasonic Tank Sensor then click Next Add device cancel 1 3 Set device type Use configuration from a template Use configuration from a profile Device type Modbus B Device profile Ultrasonic Tank Sensor v1 0 6 Click Next in the following dialog to accept the default Modbus settings Add device cancel 2 3 Set device properties use device name from template Device name Ultrasonic Tank Sensor v1 0 Modbus slave 20 Modbus IP Modbus port 7 Click Save to save the new device configurati