1. Do not open or mutilate the batteries Released electrolyte may be toxic and it is harmful to the skin and eyes Failure to follow these instructions can result in death or serious injury The battery in the Back UPS is not user replaceable Contact APC by Schneider Electric Support for a list of authorized service centers Transfer Voltage Voltage regulation The Back UPS will switch to battery power if the utility input voltage level becomes too low or too high or if the utility power is experiencing voltage fluctuations No Load Shutdown The no load shutdown feature works when the Battery Saver mode is enabled and the Back UPS is in the On Battery mode The Back UPS will shutdown if it cannot sense power is being drawn by the connected equipment for more than 5 minutes Disable Battery Saver mode if only low power consuming equipment like ADSL modem or wi fi router is connected to the Back UPS Back UPS BX600CI IN Specifications Input Voltage 230 VAC nominal Frequency 45 65 Hz Under voltage Transfer 145 VAC Over voltage Transfer 290 VAC Output UPS Capacity total 600 VA 360 W Transfer Time 10 ms typical Protection Utility input Surge Full time 160 joules and Filtering Protection Overload Resettable circuit breaker Battery Type maintenance free 12 V 7 2 Ah Typical Recharge Time 5 to 6 hours typical for 90 charging for a fully discharged battery with 50 load Physical N
2. e Be sure the air vents on the UPS are not blocked v4 x x x Allow adequate space for proper ventilation e Environmental factors impact battery life Elevated ambient temperatures poor quality utility power and frequent short duration discharges will shorten battery life e Connect the Back UPS power cable directly to a wall outlet Do not use surge protectors or extension cords Back UPS BX600CI IN Installation Connect equipment to the outlets o 3 Ozal ou O OO Oo 6 OO bu348a POWER ON OFF button and LED Press the POWER ON OFF button to switch the UPS on or off The LED illuminates green to indicate that power is supplied to the connected equipment both on mains and on battery The LED illuminates red to indicate errors Charging LED The LED illuminates to indicate the battery is charging Once the battery is charged the LED will turn off BATTERY SAVER button and LED Press the BATTERY SAVER button to activate the battery saver feature Battery saver LED will illuminate to indicate the UPS is working in the battery saver mode This feature helps the UPS to offer consistent runtime during the lifetime of the battery It increases battery life up to two times Runtime of the connected equipment will reduce when this feature is enabled See also No Load Shutdown on page 4 Battery backup plus surge arrest out
3. Corrective Action The e The Back UPS power Verify that the power cable plug is securely Back UPS cable is not securely connected to the wall outlet is operating connected to the wall on battery power outlet while The wall outlet is no e Verify that the wall outlet is receiving utility connected longer receiving utility power by checking it with another device to utility power pomer e The circuit breaker has Press the thermal circuit breaker on the rear tripped panel The Back UPS is No action is necessary The Back UPS will performing an automatic complete self test and work on mains within 11 self test seconds e The utility input voltage If the voltage is beyond acceptable range of is out of range 145 V to 290 V or the frequency is beyond e The frequency is out of acceptable range of 45 65 Hz then UPS will range switch to battery No action is required e The waveform is distorted The The UPS battery is weak Allow the Back UPS battery to charge for Back UPS due to a recent power 8 10 hours before using the Back UPS The Sea aie outage or is near the end of battery requires recharging after an extended expected its service life outage amount of Elevated ambient temperatures poor quality backup utility power and frequent short duration time discharges will shorten battery life Connected The Back UPS has Disconnect non essential equipment one device equipment experienced an overload lat a time to reduce the overl
4. is at a complete discharge state and apogee UPS the Back UPS stops providing output power Once utility and then shuts Shutdown power is restored the Back UPS will return to normal off operation Press POWER ON OFF button to return to normal operation if the Back UPS does not return to this status Tlluminates Constant tone Replace Battery Battery is at the end of its life and needs green for 10 seconds and for 2 seconds to be replaced s A followed by Contact APC by Schneider Electric support illuminates red for 2 40 seconds seconds gap alternately Flashes green None Online On Battery self test The Back UPS is every second performing a self test Illuminates Starts two No load shutdown warning Battery Saver mode is green and minutes enabled and the Back UPS is in the On Battery mode The aa before Back UPS is not connected to any load The Back UPS seconds shutdown will turn off after 5 minutes See No Load Shutdown on Two beeps page 4 every 10 seconds Back UPS BX600CI IN Visual Audible indicator indicator Condition Flashes Red Beeps on and Online Overload Power drawn by the load from the UPS every second off for two exceeds the capacity of unit Disconnect non essential seconds equipment one device at a time until the overload alternately condition is corrected Flashes Red Beeps every 2 On Battery Overload While operating on battery power on and off for two seco
5. Arc by Schneider Electric User Manual Back UPS BX600CI IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install operate service or maintain it The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death 4 WARNING WARNING indicates a potentially hazardous situation which if not avoided can result in death or serious injury 4 CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in minor or moderate injury CAUTION CAUTION addresses practices not related to physical injury including certain environmental hazards potential damage or loss of data Inventory Safety and General Information e This unit is intended for indoor use only e Do not operate this unit in direct sunlight in AN an contact with fluids or where there is excessive ryt dust or humidity
6. ected an internal error Red and is no longer providing power to the connected Red LED Continuous equipment N illuminates for tone for 3 Contact APC by Schneider Electric support ora minutes then once every 7 beeps once seconds for 20 every 7 minutes seconds for 20 minutes Back UPS BX600CI IN 7 Visual Audible indicator indicator Condition Charging LED Illuminates None Battery charging The UPS battery is charging green Not None Battery fully charged The UPS battery is charged to illuminated capacity The Back UPS is in inverter mode Battery saver LED Illuminates None Battery saver mode The UPS is working in the battery green saver mode Troubleshooting Problem Possible Cause Corrective Action The The Back UPS is not Be sure that the Back UPS is securely connected Back UPS connected to utility power to the utility power outlet will not turn on The thermal circuit breaker Disconnect nonessential equipment from the has tripped Back UPS Reset the thermal circuit breaker Reconnect equipment one at a time If the circuit breaker trips again disconnect the device that caused the short circuit Press POWER ON OFF button to supply power to the connected equipment The internal battery is not connected Battery is not user replaceable Contact APC by Schneider Electric support Back UPS BX600CI IN Problem Possible Cause
7. et Weight 5 kg Dimensions H x W x D 14 2 cm x 10 0 cm x 28 3 cm Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 15 C to 45 C 5 F to 113 F Operating Relative Humidity 0 to 95 non condensing Operating Elevation 0 to 3000 m 0 to 10 000 ft 3 power outlets With battery backup and surge protection Power Cord 1 2 meters 25 C The battery life is reduced if it is continuously operated in temperatures more than Back UPS BX600CI IN Status Indicators Note If the Back UPS is in fault condition press POWER ON OFF button once to clear the fault If the fault persists contact APC by Schneider Electric support Visual Audible indicator indicator Condition Power on off LED Illuminates None Power On The Back UPS is supplying utility power to Green the connected equipment Starts after 40 seconds delay 2 quick beeps at the start and 1 beep every 40 seconds On Battery The Back UPS is supplying battery power to the connected equipment Flashes Green 1 beep every Low Battery Fault The Back UPS is supplying battery second power to the connected equipment but the battery is near a total discharge state The Back UPS has less than one minute of runtime remaining before shutdown Flashes Green Long beep for Low Battery Shutdown Fault During on battery for g 4 sec before operation the battery
8. ice Representative will visit your location and try to resolve the issue APC by Schneider Electric Customer Support India Internet http www apc com support Toll Free BSNL network 1 800 425 4272 All other networks city code 39022272 E mail indiainfo apc com 2014 APC by Schneider Electric APC the APC logo and Back UPS are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks 990 4896A are property of their respective owners 3 2014
9. lets These outlets help provide battery backup power to the connected equipment for a limited period of time during power outages and voltage fluctuations The Battery Backup outlets provide battery power to connected equipment only when the Back UPS is turned on Connect equipment such as desktop computer modem or other data sensitive devices to these outlets Note Connect equipment to these outlets using a standard molded 6 A plug Do not use surge protectors or extension cords Thermal circuit breaker Press to reset in case the unit trips due to any overload condition See Troubleshooting on page 8 for details Utility power cable Use this cable to connect the Back UPS to utility power Back UPS BX600CI IN Turn On the Back UPS Press the POWER ON OFF button located on the front panel of the Back UPS The Power On Off LED will illuminate and a single long beep will be audible to indicate that the Back UPS is providing protection for the connected equipment The Back UPS battery charges to capacity during the first 10 hours while connected to the utility power The Back UPS battery will charge while the Back UPS is turned on or off as long as it is connected to utility power Do not expect the battery to run for its expected capacity during the initial charge period Battery Replacement A WARNING HAZARD OF EXPLOSION Do not dispose of the batteries in a fire The batteries may explode
10. nds alternately seconds for 30 seconds and the UPS is shutdown the connected equipment draws more power than the battery capacity can provide Disconnect non essential equipment one device at a time until the overload condition has been corrected If the problem persists contact APC by Schneider Electric support Short circuit error The UPS is on battery and short circuit occurs at output Disconnect one device at a time to check if the condition can be corrected If problem persists contact APC by Schneider Electric support Temperature error The UPS is over heated UPS may shutdown if this error is not corrected Disconnect non essential equipment to correct this error Note The UPS will beep and the red LED will illuminate till the internal temperature reaches the normal range Flashes Red for one second every seven seconds Beeps for one second every seven seconds Over Temperature on mains UPS has exceeded the over temperature threshold Note The UPS will beep and the red LED will illuminate till the internal temperature reaches the normal range Flashes Green Long beep for Over Temperature on battery UPS has exceeded the once every 4 seconds over temperature threshold ae before UPS Note The UPS will beep and the red LED will illuminate after 32 shut off till the internal temperature reaches the normal range seconds Tlluminates Constant tone Internal error The UPS has det
11. oad condition loses power condition The Back UPS has exhausted its available battery power The Back UPS can operate on battery power for a limited amount of time The Back UPS will shut down when the available battery power has been exhausted Allow the Back UPS battery to charge for 8 10 hours before using the Back UPS The equipment connected to the Back UPS does not accept the step approximated sine waveform from the unit The output waveform is designed for computers and computer related equipment It is not designed for use with motor type equipment The Back UPS may require service Contact APC by Schneider Electric support for further troubleshooting Back UPS BX600CI IN Service If the unit requires service do not return it to the dealer Follow these steps 1 Review the Troubleshooting section of the manual to eliminate common problems 2 Ifthe problem persists contact APC by Schneider Electric Customer Support a Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models b Call APC by Schneider Electric Customer Support and a technician will attempt to solve the problem over the phone If this is not possible the technician will issue a Service Request Number c Ifthe unit is under warranty the repairs are free An Authorised Serv
Download Pdf Manuals
Related Search
Related Contents
Digital Media Adapter DMA-100 PAMPA - Manual de usuario - v1 Télécharger - Digivue France Iniciar o Video Management System HDD収納ケース取扱説明書 Ce manuel ne prétend pas remplacer un äourïsîeäîüëäâ mais si Ext. AIRCOOLAIR U.E_IOM_MIL78S-0405 04-2005 Copyright © All rights reserved.
Failed to retrieve file