TELL AMR-08 Programming manual
Contents
1. Acron DTMF Dual DTMF 4 18 1400 Hz Ademco HighSpeed Dual DTMF 4 8 1 1400 Hz SIA FSK level 1 2 3 FSK mark FSK 110 300 baud SIA data packets tone data BodyGuard CID 2W DTMF DTMF Contact ID DTMF NGN FB Request 2100Hz Receiving of the format depends on telephone line card settings 27
2. 4 IP card optional Receiver has 8 slots to connect IP Ethernet based receiver cards IP cards can work in standalone mode they control individually the incoming events through Ethernet line Then they forward the events to central processing unit of main receiver through internal receiver bus By means of IP cards gives extended range in IP receiving functions comparing to CPM card in base receiver unit Additionally it provides possibility to connect the system to a secondary Internet provider 2 5 Monitoring software compatibility The device can work with the most generally used monitoring software packages please consult with your distributor about recommended monitoring PC software 3 SYSTEM PROGRAMMING FROM RECEIVER MENU After completing instructions from Installer Manual it is time to start TELL AMR 08 monitoring receiver programming The main settings can be done through the receiver menu displayed on LCD The starting display LED signals of monitoring receiver and the functions without user code are shown in User Manual F1 F2 F3 F4 After turning on the receiver and system boot the display above is shown on LCD screen F1 F4 buttons there is the assigned function above each button can be used for navigation in menu and they can be used also to execute functions which are protected with password and not mentioned in User Manual Note After the first start of the device it is
3. has lots of noises or low level for example GSM it may occur The receiver converts all A hexadecimal character to 0 character TROUBLE Receiver displays telephone line error but the line is connected properly SOLUTION lt is possible that telephone line card had over potential In this case only over potential protector module should be changed in card TROUBLE The receiver unit freezes because of any external reason SOLUTION With F3 UTIL F3 RESET F3 RESET buttons there might be software restart if it is not working restart with hardware reset button backside TROUBLE The receiver sends events continuously to PC software without any reason SOLUTION Memory reset of the receiver should solve the problem with F3 UTIL F3 RESET F2 MEMORY buttons 6 TELL AMR 08 TESTING When all setting is finished it is possible to test TELL AMR 08 unit Testing is also useful to test data sending from an external installation place The testing software in the given local network can help a lot to check monitoring transmission and find the reason of possible problems For test please use ipt exe software in the following way e IP Communication Tester vi Local IP Name f 92 168 1 179 Richard PC Your IP 81 182 46 243 Receiver IP address fi 23 0 189 17 Domain oo TCP UDP Receive Port 9999 Pass Shell Telnet Port 23 Pass Web Server Port 80 Pass 1 Digital Receiver 1
4. sent with 0000 client account except IP ERROR IP RESTORE messages which are sent with the given client account where IP communication was lost 25 9 COMPATIBILITY TELL AMR 08 receiver is compatible with the following communicators and monitoring software types Monitoring software The device can work with the most generally used monitoring software packages please consult with your distributor about recommended monitoring PC software IP communicators Please consult with your distributor about recommended devices GPRS communicators Please consult with your distributor about recommended devices 26 9 1 Telephone line card communication formats Name HSK Data Speed Format Ext Kissoff Ademco Slow 1400 Hz 1900 Hz Pulse 10 bps 3 1 3 2 4 1 4 2 1400 Hz Silent Knight Fast 1400 Hz 1900 Hz Pulse 14 bps 3 1 3 2 4 1 4 2 1400 Hz Franklin Sescoa 2300 Hz 1800 Hz Pulse 20 bps 3 1 3 2 4 1 4 2 2300 Hz Radionics 1400 Hz 1800 Hz Pulse 40 bps 3 1 4 2 3 1 p 4 2 p 1400 Hz Radionics 2300 Hz 1800 Hz Pulse 40 bps 3 1 4 2 3 1 p 4 2 p 2300 Hz Sescoa SuperSpeed 2300 Hz 1800 Hz Pulse 40 bps 4 3 p 2300 Hz Contact ID Dual DTMF Contact ID 1400 Hz Sur Gard 2300 Hz DTMF 4 1 4 2 4 3 4 3 p 2300 Hz Sur Gard 1400 Dual DTMF 4 1 4 2 4 3 4 3 p 1400 Hz Ademco Express Dual DTMF 4 2 1400 Hz
5. 2 Save settings from the card CPM LC IP planned to update with Terminal software please check 4 System programming with PC software chapter Please close monitoring software if it is running 3 Start Receiver Uploader program for firmware upgrade A Receiver Uploader v1 25 COM3 9600 8 n 1 MA _ Please read and save device parameters before start programming 1 Step 2 Step Select programming type and load file Close connected monitoring software Programming via CPM COM USB 3 Step CPM COM A USB A Select PC com port coms v 9600 v C CPM Data em LC Tel Line Card 4 Step sy Check available line cards IP Card USB A i ar Select line card no Line Card Y 6 Step 0 Start programming Direct Card Programming 4 Choose item for upgrade 1 STEP then NEXT 21 CPM CPM card cpm bot programming CPM Data Receiver menu language cpm bin Web browser menu cpm dat Web logo jpg update LC Tel Line Card Telephone line card Ic bot upgrade IP Card USB IP extension card ip ipx upgrade Not possible through CPM 5 The following window will pop up if you use P Card update e 3 IP Uploader s s on Communication Settings Serial Port Connect COM Baudrate com2 x 57600 es V Select i Ethernet IP Address Select 6 Choose the proper firmware file for upgrade 2 STEP then NEXT Note In case
6. AMR 08 password is also needed for web browser password generation 11 Web Password Generat Account ID ooo oam validity day j Unlimited Receiver Password web Password 3 Digital Receiver Note After changing all kind of IP parameters please always restart the receiver unit For this exit the menu then F3 UTIL F3 RESET F3 RESET F3 TIME Date and time setting function without password details in User Manual F4 BACK Navigation back with one menu level in receiver menu 3 3 IP communication status menu From event list display it is possible to switch to IP communication status menu with long DISPLAY button push 3 seconds Lots of IP communication related function can be checked here During menu access DISPLAY LED is flashing The following data can be seen Receiver LAN IP address Receive port Netmask Remote programming port Gateway Web browser access port Public IP WAN monitoring status SCK Opened sockets number TCM IP monitored device number In appearing events first digits are the client account 5451 then the IP monitoring period 00005 and at the end there is the event code 14AA 12 3 4 DISPLAY card programming and status checking After pushing the DISPLAY button DISPLAY LED lights continuously you can enter into the following window F1 F2 F3 F4 CARDS Telephone line cards IP cards status READ
7. Communication error on COM A port COM A RESTORED 86 Communication restored on COM A port COM B ERROR 87 Communication error on COM B port COM B RESTORED 88 Communication restored on COM B port TCP IP ERROR 89 For future usage TCP IP RESTORED 8A For future usage IP LINK ERROR 8B Network cable unplugged IP LINK ACTIVE 8C Network cable connection OK PRINTER ERROR 8D Printer is off or no paper PRINTER OK 8E Printer is ready to use RECEIVER RESET 8F Receiver restarted TIME DATE SET 91 Receiver date and time was set PROGRAM MODE 92 Programming through serial port PROGRAM END 93 End of programming through serial port REMOTE ACCESS 94 Programming through IP network REMOTE END 95 End of programming through IP network MANUAL ACK 96 Manual acknowledge of events in receiver ACCESS GRANTED 97 Successful password usage in receiver menu ACCESS DENIED 98 Incorrect password usage in receiver menu RECEIVER TAMPER 99 Receiver tamper violation if tamper is enabled REC TAMP RESTORE 9A Receiver tamper restored if tamper is enabled IP WAN ERROR 9B External WAN connection test failed IP WAN RESTORE 9C External WAN connection test OK EVENT OVERFLOW 9E Event buffer overflow at COM A port EVENT OVERFLOW OF Event buffer overflow at COM B port P ERROR A IP RESTORE 3692 IP communication restored for the given client account where communication was lost 24 System Message Code Descripti
8. Enter the P address or Domain name of the monitoring station 2 Set the ports for communication with monitoring station Receive Port Monitoring transmission port Shell Telnet Port Remote programming port Web Server Port Event list access through web browser port 3 After click to Test button it can be seen that test is successful PASS or not FAIL 4 If you want you can change the program settings in Options part Enable TCP Test Report TCP connection test with test message Enable UDP Test Report UDP connection with test message Invisible TCP UDP Test Test message can t be seen on receiver Enable AES Crypted Test Report AES Key Test of AES encryption function Received events in TELL AMR 08 can be checked easily with a simple web browser access For this IP address and port if it is different from 80 of TELL AMR 08 unit should be typed in a web browser Internet Explorer recommended Then all received events from receiver memory can be seen Note For the operation of event list review through web browser the IP ADDRESS and HTTP PORT should be enabled in rooter as well Note Web browser access can be limited with password generated by wpg exe software Note Web browser access function usage is described deeply in receiver TCP IP port settings in this manual You should see a similar window with refresh and page up down in web browser Event Log ID All 2012 03 28 15 36 06 Account event
9. NG always consult with your distributor Note After choosing the telephone line card CARDS 1 8 with F3 STATUS button 14 you can check the firmware version of the line card for example LC 2 20 BA14 4 SYSTEM PROGRAMMING WITH PC SOFTWARE To use the monitoring receiver with monitoring PC connect the COM A USB A port to the serial port of the monitoring PC USB connector Driver installation is automatic from Windows 7 After this the appropriate monitoring software settings should be done it means usually the serial port settings The process is the following in PC software example different in every software type Start monitoring software Start Setup part and log in ID 1 Password 1 Setup menu Hardware Setup Digital Receiver 1 Digital Digital Receiver type DR 21000 y ec and process incoming messages Port Setting COM a Baud Rate 9600 v Databits Parity Stopbits HeartBeat signal timeout 30 In pop up window basically only Receive and process incoming messages option should be enabled then set the proper COM port checking in Windows OS Control Panel Hardware Device Manager then apply changes After this the COM ERROR should be restored in monitoring receiver and receiver events are displayed on monitoring software screen Note If you need direct connection of IP card to monitoring software through USB connector of the card set Baud Rate value
10. TELL AMR 08 Monitoring Receiver Programming Manual 28 01 2014 CONTENT O AN A UU A INT ROTC BION Ad 3 SYSTEM STRUCTURE sess sugars alata ena adnate did 3 e ad la ola aes 3 2 2 LC telephone line card optional A aos 4 DS PWR power SUPP Vs Cat ls A co Gea EN DAR oan cue da bod a wh see Soa Or ome A ness 4 ZA VP card optional a ta 4 2 5 Monitoring software compatible ad 4 SYSTEM PROGRAMMING FROM RECEIVER MENU ocoococccccoconnconcnnconconnonncnnonnonncnncnncnncnnnns 5 SES UTIL MEN ssar aa iio ETE 6 32 SE DUP MENU ee e A A A do J 33 IP communication status mMenu NS AAA A 12 3 4 DISPLAY card programming and status CheckiNg oooonccinncninconoccconccnnoncccnanancnonancnonnns 13 3 5 DISPLAY CARDS telephone line card progra MMINB ooocooccconcconcconnnconncnnnoconccnnnncnncnnnns 14 SYSTEM PROGRAMMING WITH PC SOFTWARE cocooccccoccoconccononncnncononononccnnonncnnonncnnnonnnonos 15 TROUBLESHOO LING tii 17 v TELGAMR O8 TESTI O aos 19 FIRMWARE UPGRADE AND OTHER FUNCTIONS cooccococcoconccononnonncnnconcnnnonnconccnnccnnncnnncnnos 21 SYSTEM MESSAGES i cssyshcestcsesstuayshapadionsandsnceahapeasivbnsd dwar EOS EN OE NHA oat ESTEA R S 24 JCOMPA TIB E E E O aE 26 9 1 Telephone line card communication forMatS ooooocnnoccnocaconccoonononnconnconnnonnonnn ono cnnn cnc nnncnanns 27 1 INTRODUCTION Thank you for choosing our product This modern and reliable monitoring receiver not only guarantees the h
11. Y Telephone line card IP card is OK RING Ring on telephone line card INCOMING CALL Telephone line card received the incoming call incoming event codes can be seen LINE ERROR Card is OK but telephone IP line has trouble ID xxx Call is from xxx phone number F1 MON ON OFF Speaker On Off F3 STATUS Card status and firmware version checking RESET button for card restart F4 HANG UP To abort stucked phone call 3 5 DISPLAY CARDS telephone line card programming After DISPLAY button push DISPLAY LED is steady and choosing telephone line card CARDS 1 8 it is possible to enter the chosen telephone line card settings menu with F2 SETUP button F1 F2 F3 F4 It is recommended to modify the following settings only if it is necessary e HSK LENGTH Here you can change the Handshake and Kissoff length of line card e CALLER ID ENABLE The telephone numbers of the call to the given line card appears on LCD display of TELL AMR 08 unit if telephone number sending is enabled at service provider and Caller ID Message is enabled in TELL AMR 08 unit DISABLE Telephone numbers from the given line card are not shown on TELL AMR 08 Note Function might be useful for debugging during communicator connecting to monitoring station as the phone number is displayed in case of bad communication format too Note Before changing HSK SEQUENCE TIMI
12. a function then choose the latest language file from distributor for example cpm250_EBA14 bin file for upgrade language Note For individual text of events use Terminal software Codetable et files When web browser is used for event list review it is possible to put the company logo to the web browser site For this the logo should be uploaded with Receiver Uploader program after choosing CPM Data upload function Note Recommended resolution for logo is 600 wide x Any height JPG format size cannot be bigger than 20 kbyte To upload newest web browser menu file you can also use Receiver Uploader program CPM Data function After uploading the cpm dat file what you wish to use you can see the new web browser display Note Web browser menu of IP card can only be uploaded on the web browser site of IP card Upload is possible in Data Upload menu If the web browser site cannot be uploaded from any reason you can use IP address then mpfsupload command for data upload for example 192 168 1 232 mpfsupload of ip bin file Default password for web file upload is 1234 23 8 SYSTEM MESSAGES System Message Code Description AC ERROR 81 No main AC voltage AC RESTORED 82 Main AC voltage restored BATTERY LOW 83 No battery or low battery voltage level BATTERY OK 84 Battery connected battery voltage level OK COM A ERROR 85
13. always recommended to apply default settings F3 UTIL F3 RESET F1 DEFAULT Default password for menu access AHOV F1 F2 F3 F4 Note It is strongly recommended to change default password with Terminal software F1 F2 F3 F4 Code entering is possible by choosing characters with F1 F4 buttons more pushes of one button can be used to change character backspace is with lt button code apply with ENTER button exit with DISPLAY button After code entering it is allowed to enter into receiver menu without entering the code again for 3 minutes since the last button pushing 3 1 F3 UTIL menu F1 F2 F3 F4 F1 REPORT To resend receiver memory stored events to monitoring software F1 LAST 50 To resend last 50 events to monitoring software F2 TODAY To resend all events from the last day to monitoring software F3 ALL To resend all receiver events to monitoring software F2 PRINT If printer is connected events stored in receiver memory can be printed F1 LAST 50 To print last 50 events F2 TODAY To print all events from the last day F3 ALL To print all receiver events F3 RESET Different level resets of the receiver unit F1 DEFAULT This function is to delete full event memory and set all settings back to default value F2 MEMORY This function is to delete full event memory then receiver re
14. as any trouble B port can work as a replacement For this switch on OPERATION MODE to RECEIVE on port A and to NORMAL on port B Please connect PC connector from port A to port B e RECEIVER ID The option has importance when there are more receivers connected to the same monitoring software If each receiver has different number in event list it can be seen which receiver sent the given event e PORT SETTING You can check the actual serial port settings in this menu Default values 9600 speed 8 NONE Data Bits amp Parity F2 PORTS F3 TCP IP In this menu you can configure the main monitoring receiver IP parameters and settings Note After changing all kind of IP parameters please always restart the receiver unit if restart doesn t happen automatically For this exit the menu then F3 UTIL F3 RESET F3 RESET F1 F2 F3 F4 It is recommended to modify the following settings only e IP ADDRESS Here you can define the TELL AMR 08 unit private internal IP address in local area network Take care to not use address which is used by another device or which can be given by DHCP service e NETMASK The used subnet mask in local area network GATEWAY This address is required if the device optionally wants to realize external communication for example for WAN Test Most of the times the gateway address is the same as rooter private internal address in local area network
15. ay as well where received events can be seen and basic settings can be done 2 2 LC telephone line card optional Receiver has 8 slots to connect LC telephone line cards LC line cards can monitor one telephone line Each telephone line card have memory to store up to 500 events or caller ID Caller ID function is built in the caller telephone number is stored and can be transmitted to monitoring computer Line cards support two way audio communication also Line cards are continuously monitored by CPM All line card troubles are displayed immediately at LCD display and transmitted to monitoring computer The line card monitors the connection with CPM as well if it detects trouble automatically switches to standalone operation mode In this case it continues event receiving but stores them in its own memory All received events will be sent automatically to CPM when the connection is restored 2 3 PWR power supply card PWR power supply card ensures voltage for all cards in the system The input of PWR requires 16 5 VAC 18 VDC which is generated by an external transformer unit power supply unit PWR has got battery charging circuit batteries can be connected to external connectors In case of main power trouble battery powered operation is switched automatically The capacity of batteries should be between 7 Ah and 15 Ah The PWR continuously check the state of main power and batteries and it reports the status to CPM unit 2
16. e RECEIVE PORT hexadecimal The port can be defined where IP based IP GPRS messages are coming to the monitoring station Configuration is in hexadecimal mode but in brackets the decimal port number also can be seen e PROGRAM PORT hexadecimal The port can be defined where receiver remote programming through Internet is possible Configuration is in hexadecimal mode but in brackets the decimal port number also can be seen Note For the operation of remote programming the IP ADDRESS and PROGRAM PORT should be enabled in rooter as well Port Forward Virtual Server NAT in rooter menu IP MONITORING If this option is enabled the first 255 from receiver startup user accounts received through IP channel will be monitored If there is no event with the given user account through IP line until the MONITOR PERIOD the receiver will generate IP Communication Error message with the given client account e TEST FILTER If IP MONITORING is enabled this option can be used to filter test code by the receiver The defined event codes in CID TEST EVENT menus will be filtered the first test event after midnight receiver start for each user accounts is always displayed MONITORING PERIOD The time period can be defined within the receiver wait IP communication for the first 255 user accounts If there is no event with the given user account through IP line until this period the receiver will generate IP Communication Error message wi
17. e as well In monitoring PC Control Panel Hardware Device Manager application you can check which COM port appears disappears in device list during plug unplug TELL AMR 08 cable Please check whether COM port setting is correct in monitoring software 17 TROUBLE After proper IP configuration receiver events are not coming through IP SOLUTION Don t forget to allow used ports in rooter Port forward menu in rooter TROUBLE Event names are missing or not correct in receiver display SOLUTION Because of the new functions there might be new menus and events in receiver so receiver language should be updated regularly see Firmware upgrade TROUBLE There are strange internal messages in receiver with 0000 client account SOLUTION It is possible that any of the external device alarm control panel has 0000 client account Never use 0000 client account in alarm control panel side TROUBLE There is Fault call on telephone line card message on display SOLUTION Basically it is not error it means only that the format of communication has some problem at alarm control panel side TELL AMR 08 can t understand properly By means of proper communication format the problem is solved If the alarm control panel can t use appropriate communication especially with old panels please consult with your distributor about modifying receiver handshake settings TROUBLE Wrong received events data SOLUTION If the telephone line
18. fime estes User Close 02 001 2012 03 28 15 36 03 User Close 01 001 j4 2012 03 28 15 35 59 1E0 9999 User Open 02001 1 2012 03 28 15 35 56 1C0 Recent Close 02 000 012 03 28 15 35 52 180 012 03 28 15 35 48 180 012 03 28 15 23 44 hn NIIN N E E 3 oo 160 Opening 03 001 2012 03 28 15 23 41 140 5451 Opening 02001 1201270328 15 23 38 120 012 03 28 15 23 34 100 5451 Closing o3 001 A 2012 03 28 15 23 31 20E0 2012 03 28 15 23 2 20C0 5451 Closingo1r001 1 2012 03 28 15 23 25 Refresh lt Page 1 gt NR Note If you type in web browser the list php a 1234 command after the receiver IP address only the events with the given user account can be seen in the list in this case 1234 user account For example 74 125 232 210 8800 list php a 54A5 it means only 5405 user account events appear in the list Note Always use A digits instead of 0 digits in client account Note The status and event list of IP Ethernet receiver card can also be checked through web browser after typing the IP address of the card 20 7 FIRMWARE UPGRADE AND OTHER FUNCTIONS It is recommended to upgrade regularly CPM card basically the receiver itself firmware LC card telephone line receiving unit and IP card IP extension card firmware to use new functions and eliminate possible bugs Firmware upgrade can be done by the following steps 1 Get the latest firmware files from your distributor CPM LC IP
19. he required settings in Terminal software Note The software functions are shown in Terminal help menu File View Edit Communication Help File name C Program Files Terminal v2 RECEN 4 MA i irmware j KA ES ON 2 Last version firmware C927 Device version Open Save Settings Read Write Advanced Magyar Help Device info Default System Receiver Mode Standalone Standalone Buzzer Operation Enable Enable 6 Click to Communication Write Data menu to send the modified settings to receiver Note Before reading LC telephone line card data you should select number of the line card in the pop up window Note During data reading and sending CPM firmware version can be checked 5 TROUBLESHOOTING TROUBLE Any abnormal operation in functions during the usage of the device SOLUTION Firmware upgrade with the newest firmware file usually solve these kind of problems see Firmware update part in manual TROUBLE Receiver unit restarts or freezes without any reason when touching device housing or LCD display or when push any receiver button SOLUTION Receiver grounding is not connected properly so the electrostatic charges causes these problems Use the device only with appropriate grounding Usage without grounding may cause the device and it is not warranty problem TROUBLE No connection between monitoring PC and receiver unit COM ERROR SOLUTION Check the cable plugging in PC side and in receiver sid
20. ighest level of security but also it is a useful colleague in the life of every monitoring company because of its user friendly handling and intelligent functions To use the highest range of provided functions please read carefully the Programming Manual For the confident programming and secure usage please keep all warnings in Installer Manual with highly focusing to security directions 2 SYSTEM STRUCTURE TELL AMR 08 monitoring receiver provides complex and reliable solution to build up a modern monitoring station The device can receive signals from alarm control panels through IP network and telephone line Due to the universal operation the device can receive all standard and most of the non standard signals from alarm control panels and communicators With combination of an appropriate PC based monitoring software it guarantees not only reliable signal transmission but also easy to use operator interface The system consists of the following devices 2 1 CPM card Central processing card CPM which controls the operation of the receiver CPM contains two serial ports respectively 2 high speed USB ports one Ethernet port and one parallel printer port CPM card can store up to 2000 events in its non volatile memory If the connection fails with monitoring computer the receiver stores events in its own memory and all events will be sent automatically when the connection is restored CPM controls the graphical LCD displ
21. of IP2 card you should select ip ipx firmware file in Connect Load File menu 7 Choose the COM port where receiver is connected 3 STEP then NEXT Note The baudrate should be set to 57600 in case of IP card update IP card update through Ethernet is only possible through local network Note Line card update should be done separately for each line card after choosing the line card number for upgrade 8 Upgrade process can be started with START button 9 Do not forget to send back the saved card CPM LC IP settings at the end of the upgrade please check 4 System programming with PC software chapter 10 To use new functions it might be required to get the latest Terminal software with the newest ET setup files please download and use newest version Note If there is any problem during CPM firmware update current blackout cable remove other repeat the upgrade steps from 3 point start Receiver Uploader If there is any problem during update steps you can try the following 22 e After choosing COM port 6 point 3 STEP choose the Selected Speed Without checking option and set speed to 57600 e Turn off the power supply of TELL AMR 08 unit Turn on the AC supply of TELL AMR 08 unit then immediately click to START button for firmware upgrade start Event list and menu names in TELL AMR 08 unit also can be updated For this after starting Receiver Uploader program please choose CPM Dat
22. on LINE CARD RESET EO Line card restarted TEL LINE ERROR 20 Telephone line error TEL LINE OK 30 Telephone line restored FAULT CALL 40 Received call error no data receiving FAULT DATA 10 Received data error missing data CANCEL CALL 50 Call abort by the user hang up LINE CARD FAIL DO Internal communication trouble with line card System Message Code Description DATAFILE MODIFY B1 IP receiver card web browser data file modified SETTING MODIFY B2 IP receiver card settings changed IP receiver card programming through serial port IP PROGRAM MODE B3 Sor IP receiver card programming through serial port IP PROGRAM END B4 network end IP receiver card communication error on USB port SUM B9 with monitoring software IP receiver card communication restore on USB port COM RESTORED Pe with monitoring software TCP IP ERROR B7 IP receiver card TCP IP network error TCP IP RESTORED B8 IP receiver card TCP IP network restored TIME DATE SET B9 IP receiver card date and time set FIRMWARE UPDATE BO IP receiver card firmware updated IP receiver internal LAN connection gateway test LAN ERROR BB failed LAN RESTORED BC IP receiver internal LAN connection gateway test OK RECEIVER RESET BD IP receiver card restarted IP WAN ERROR BE IP receiver external WAN connection test failed IP WAN RESTORE BF IP receiver external WAN connection test OK Note System messages are
23. start F3 RESET Receiver restart without deleting any events settings F4 BACK Navigation back with one menu level in receiver menu 3 2 F4 SETUP menu F1 F2 F3 F4 F1 OPTIONS F1 F2 F3 F4 First choose the option to configure with and gt buttons chosen value is blinking For changing the value you can use F1 and F2 buttons You can apply settings with ENTER button It is recommended to modify the following settings only 7 e BUZZER OPERATE YES TELL AMR 08 buzzer is on yo can hear buzzer sound if there is new event until manual acknowledge pushing ENTER button monitoring software acknowledge NO TELL AMR 08 buzzer is off there is no buzzer signal in case of unacknowledged event F2 PORTS F1 COM A or F2 COM B F1 F2 F3 F4 It is recommended to modify the following settings only OPERATION MODE NORMAL TELL AMR 08 forwards data on the given port towards monitoring software default port for PC connection RECEIVE TELL AMR 08 can only receive data on the given port this port is to connect another receiver to TELL AMR 08 or for reserve port Note COM A and USB A ports are equivalent as the COM B and USB B ports Do not connect devices at the same time to COM A and USB A ports If it is possible always recommended to use COM A as against USB A Note If the A serial port of the receiver h
24. th the given client account e CID TEST EVENT The test event code can be defined for CID communication 0 character is displayed as A character WEB HTTP PORT hexadecimal The device provides access for event list review through web browser For this function this port should be configured If you use different port as default 80 for view event list you should type the port as well after the IP address domain name Note For the operation of event list review through web browser the IP ADDRESS and WEB HTTP PORT should be enabled in rooter as well Port Forward Virtual Server NAT in rooter menu Note It is recommended to Internet Explorer 8 or higher for event list review Note Take care to not use ports which might be used by another device for example 110 port e LINES When you use web browser to event list review here can you define that how many events are displayed in one page WEB PASSWORD NO No password is required for event list review in web browser YES Password is required for event list review in web browser Note The password for event list review is not the same as the TELL AMR 08 password Web browser access password can be created by means of wpg exe software For this it is necessary to define the client account which can be seen by the generated password All Access to all accounts the validity period of the generated password Unlimited No limit for validity and the TELL
25. to 57600 in monitoring software settings In normal case programming of the monitoring receiver unit can be done in serial port any of the COM ports or USB ports After completing appropriate IP settings programming can be done through Ethernet network as well Please use Terminal software for programming The programming steps are bellow 1 Please start Terminal software Note PC programming provides access for all system parameter settings 2 Choose the ET settings file according to the device what you want to program CPM et CPM receiver programming LC et LC telephone line card programming IP et IP Ethernet receiver card programming 3 In Communication Port Settings menu set the communication port IP address for programming Port Settings ET File Terminal Baudrate 9600 v 9600 v Databits Parity Stopbits IP Address Port fi 92 168 1 240 23 T Last Used IP Address and Port Password Show Password Cancel 4 With Communication Read Data menu you can read settings from receiver unit Note Before reading LC telephone line card data you should select number of the line card in the pop up window The highlighted firmware version means Device versi CA02 the following hexadecimal format Read data C 12 2012 Close com2 9600 N 1 A 10 October 02 2 Second day BEHREGEHEEA 45 10 5 Please execute t