Home

User`s Manual AEC9008-3 Low Ohms Adapter

image

Contents

1. AeroElectric Connection P O Box 130 Medicine Lodge Kansas Voice 316 886 3404 Email nuckolls bob aeroelectric com User s Manual AEC9008 3 Low Ohms Adapter True Donne Ams Grr Orp AL MULTIM re n Ten s DATA HALD n z r Tra 409 4K 90K 00K ayy gt 40 e AN 4 A MIA r h 0 1 A SETTING 1A SETTING UM9008 700A 12 July 2011 Page 1 of 2 AEC9008 3 Instructions The AEC9008 3 LOA is a very close approximation of a 4 wire resistance measurement adapter One set of wires takes constant current excitation out to the tips of the test clips a second set of wires takes voltages impressed between the two clips to the input terminals of the user supplied multimeter The user also supplies a 6v spring top lantern battery and hefty rubber bands to attach the LOA to the top of the battery Insert banana plugs into the voltage input jacks on your multimeter Set the multimeter to most sensitive scale 200 mV typical Make sure test clips are separated clip one lead to the insulated jacket of the other lead Use 3 rubber bands to strap the AEC9008 3 Low Ohms Adapter to the top of a 6V spring top lantern battery as shown in the photo 64 bands work good Set desired excitation current 100 mA or 1000 mA by positioning the selection jumper picture above to appropriate position Attach alligator clips across the low resistance pathway to be explored and observe reading on multimeter C
2. aution When using the 1000 mA excitation feature there is considerable heat dissipated in the Low Ohms Adapter electronics Measurements should be made in not more than 20 seconds or so whereupon the adapter should be allowed to cool 100 mA excitation measurements can be made over any necessary duration of time 100 mA Operation A reading of 200 0 millivolts is equal to a resistance of 2 000 ohms In the photo on the front of this document the multimeter reads 100 3 millivolts The test resistor is marked 1 00 ohms 1 A reading of 2 000 volts is equal to 20 00 ohms 1000 mA Operation A reading of 200 0 millivolts is equal to a resistance of 200 0 millohms Limit 1000 mA readings to 20 seconds or less with allowances for cooling between readings The Low Ohms Adapter should be removed from the battery for storage to reduce risk of inadvertent connection of test leads leading to depletion of the battery In fact if you have a 6V lantern Wallmart sells lantern WITH battery for under 5 the battery can be returned to service as a flashlight energy source UM9008 700A 12 July 2011 Page 2 of 2

Download Pdf Manuals

image

Related Search

Related Contents

Le « boum d`éclosion  O traNSPOrt  ULTRA WASH ®Dishwasher Lavavajillas ULTRA WASH  Autotek AT20KIT car kit  Manual – Interface de bus de campo XFE24A  슬라이드 1  - A.J.Pinto  HF52シリーズ取扱説明書 このたびは、HF52シリーズをお買 い上げ  TS40 温度スイッチ  Bac blanc 2012  

Copyright © All rights reserved.
Failed to retrieve file