1. U a EW GmbH Stettiner Str 38 D 33106 Paderborn PadPuls M1 Art no IM001 IM001G Valid from M Bus generation 07 Article no IMOO1 1 channel pulse collector OEM board Article no IM001G 1 channel pulse collector with case for wall mounting Contents 1 FUMEUONAl COSCO OMA as Sense sehe bee 2 fam ako alan Ana Starlet 3 ZRO UNIN SINE CS ee 3 2 2 OHENING INELCA SE ra ae an ne ee ie tee een 3 2 ON MIC CU are ee 3 3 Parametenzationusiag MBEONF en a 5 3 1 IHstalalona e enden 5 32 OPEO 5 SS ce INS 6 3 3 Sheet PadPuls M lassen nee 9 Ae M BUS TOI U am Seen ee 12 SALSENNIC ANA ee ee ee 14 PadPuls M1 User Manual 26 09 01 Version 1 3 Sin ak GmbH Stettiner Str 38 D 33106 Paderborn 1 Functional description The PadPuls M1 serves for the adaptation to the M bus system of consumption measuring instruments such as current gas or water meters However the meters to be adapted must have a floating pulse output The user can configure the PadPuls M1 with the MBCOPNF program so that the scanned impulses are converted to units such as kWh m J and so on The configuration is very easy with the MBCONF user interface When connected to the M bus the PadPuls M1 is powered from the bus A built in battery ensures that metering continues even if the M Bus fails for longer than the normal calibration time for the water meter or heat counter The battery also ensures that the meter readings and the configur
2. 1434 3 e The data block Protect index denominator numerator is specific to the manufacturer and is optional 4 Telegram to Set the Write Protection m o d a 3 4 fos 6 7 e 9 wf m mtl oe os os eps stort s Fa The write protection can only be reset by pressing the pushbutton on the circuit board PadPuls M1 User Manual 26 09 01 Version 1 3 Ba 5 Technical data Case ABS plastic colour black WxDxH 100 x 88 x 35 mm 2 cable glands PG light grey Protective class IP 50 CE marking The device is CE proofed Environment 5 GmbH Stettiner Str 38 D 33106 Paderborn Operating temperature 0 60 C Storage temperature 25 C 60 C Humidity non condensing 10 70 Specifications for the pulse generator impulse contact Potential Resistance Capacity with cable Minimum contact duration Minimum interval between 2 pulses Maximum pulse frequency PadPuls contact input Contact voltage Contact current Guaranteed debounce time Connection cable Current consumption Principle Battery Bus operation Floating isolation to earth gt 1MQ Open gt 10MQ closed lt 10kQ lt 2nF 5 ms 40 ms 12 5 Hz with pulse length pause length 1 1 2 5V to 3 4V 2uA to 4uA 1 2ms Maximum 2 m twisted pair with shielding connected only on the PadPuls side Remote power supply from M Bus with automatic changeover to battery backup upon bus failure Lithi
3. LOM Port com Be gt 54 Generation fos T ZWEI optical mode Eaudrate 2400 Maniac REL nn OO HERENERERENE ne 2400 Bd Hee T Autom readout Connect to meter Erase log Pulse counter 1 2 88 81 fe 32 45 89 Bl AC 48 BE Be Be Be Be Be BE HE Hh GH aa BF 81 Bi Bi 7S 16 f Exit nu Prater Arrar PAren A Electricity 1 kWh Er write protect Read write Z These sheet shows the actual settings and values of the PadPuls M1 The following input boxes and buttons are used to change the params of the pulse adapter Primary address ID sec adr Fabric no Medium is the M Bus address of the device Values between 1 and 250 can be entered in this field for new assignment of the address After pressing the Write button the software programs this primary address and further variable settings on this sheet into the M Bus device is the 8 digit M Bus ID identification no which is also used for secondary addressing of this adapter is insignificant for PadPuls M1 describes the measured medium of the connected meter Examples Oil Water Heat Electricity PadPuls M1 User Manual 26 09 01 Version 1 3 PQ o E 5 GmbH Stettiner Str 38 D 33106 Paderborn Multiplicator is the pulse increment multiplicator of the connected meter For each registered pulse the device adds multiplicator to the counter The numerator can take values between
4. O no counting and 255 the denominator between 1 and 255 Unit is the physical unit of the counter and of the pulse increment All proper units including variants with power of ten from the DIN EN 1434 3 are offered in the selection list Counter is the accumulated counter It has to be related to the unit mentioned above The counter can be programmed equal to the counter of the connected meter in a range of 0 to 0 to 1x10 or in detail 1 099 511 627 775 00 FF FF FF FF FF hex State is the M Bus state in hexadecimal notation Write protection is marked if the device is protected against programming Then you cannot configure the adapter The protection can be removed after opening the sealable front cover of the housing and pressing the Unprotect pushbutton Permanent error is insignificant for the PadPuls M1 Write protect Transmits a command to the PadPuls M1 to activate write protection The PadPuls then allows no further configuration It is protected against unnoticed manipulation Read reads the M Bus device and refreshes the data on the selected sheet Write sends the current options to the pulse converter which stores this data into the battery buffered memory The PadPuls M1 changes the options only if the write protect is deactivated It is recommended to read the data after writing and check it 26 09 01 Version 1 3 PadPuls M1 User Manual u gt EW GmbH Stettiner Str 38 D 33106 Paderborn N
5. ation data is maintained in RAM The battery jumper should therefore be plugged in at all times The jumper serves only to disconnect the battery from the circuitry should the battery need to be replaced Device data can be protected against unauthorized configuration The PadPuls M1 can be switched to protection mode with a special M Bus telegram Subsequent changes to device parameters cannot be made in this operating mode The protection mode can then only be disabled by opening the sealable housing and pressing the unprotect pushbutton 26 09 01 Version 1 3 PadPuls M1 User Manual 2 Installation and startup 2 1 Mounting the case The housing is fixed to the wall with two a D 6 D 5 0 screws which are screwed diagonally vall Housing through the holes marked with wall 67 The heads of the screws should be 46 all dimensions in mm maximum 6 mm in diameter so that the cover is not screwed as well D 5 D 6 P Housing Wall P y lt 80 gt lt 99 gt 98 2 2 Opening the case To deactivate the write protection the housing cover can be opened by removing the metal screws above at the left and below at the right The unprotect pushbutton is then accessible from outside the unit is unprotected by pressing this button Use a suitable adhesive seal to prevent the housing from being opened unnoticed 2 3 Connecting The following picture shows a typical
6. here PadPuls M1 of the connected device This item is read only shows the M Bus state of the connected device This item is read only lf this option is activated devices with an optical interface and protocol according to EN 1434 3 can be read and programmed using an optical reading head e g PadPuls M4 MAL The software always reads the data after writing if this option is activated useful for checking the correct programming PadPuls M1 User Manual 26 09 01 Version 1 3 Zs 5 GmbH Stettiner Str 38 D 33106 Paderborn Log Window The so called log window is always visible All M Bus communication steps are logged in this window Data is displayed in hexadecimal notation It is possible to mark outputs in the log window and copy them with the keys CTL C to the windows clipboard Then the data can be easily imported to any text editor for documentation As soon as the max storage capacity of the window is achieved no more data is logged If you want to log further you must delete the logged data The following buttons are also always visible Erase log clears all outputs inside the log window Exit terminates the program and stores the current setting of serial port port no into the INI file 8 26 09 01 Version 1 3 PadPuls M1 User Manual Prim address 1 State ID sec adr o 094532 m inte potesia Fabric no Medium a i E r 1 Pulse counter 1 Unit Counter
7. installation including the PadPuls M1 PadPuls M1 Pulse generator 095327 6 PadPuls M1 User Manual 26 09 01 Version 1 3 Ba 5 GmbH Stettiner Str 38 D 33106 Paderborn After opening the housing please lead the M Bus cable through the left cable gland of the cover and connect the cable to the left terminal Then do the same with the cable of the pulse generator right side Please connect an optional shielding to the terminal labeled with Schirm Connect the shielding only at the PadPuls e Impulse devices with floating contacts reed contacts are connected to the terminals marked with pulse using any polarity If cable shielding is available it can be wired single sided to the terminal marked with shield e Impulse devices with optocouplers or electrically isolated transistor outputs must be connected to the pulse with the correct polarity The left hand terminal is the positive connection and the middle terminal the negative connection The following graphic shows the position of the terminals and the button jumper battery lt lithium battery 3 0V 1800 mAh i terminal M BUS terminal pulse db amp unprotect key shield 26 09 01 Version 1 3 PadPuls M1 User Manual
8. is time 08 reserved range from 01 to 0F e Status bit 7 MSB 1 write protection set 0 write protection removed e VIF Set by the user VIF unit with decimal power MSB not set e Count Meter reading most significant byte Count6 always zero e Numerator Denominator Impulse value increment in multiples of the VIF per impulse Numerator 1 Pulse __ e VIF Denominator 26 09 01 Version 1 3 PadPuls M1 User Manual u gt EW GmbH Stettiner Str 38 D 33106 Paderborn 4 Configuration Telegram sel T2 Is Tets ts Toto Tome en iene ser ieor DE a o o r rae or a or mtl e Ice fc fe ts aaa o Bye 14 a 16 a i 19 20 a 22 23 2a 25 26 Name D2 103 104 MAN1 MAN2 GEN MED DiF3 VIF3 Counti Count2 Count3 Counts tt I ea ala aan Inte Name Coun Count Spez Index Manes pause cs Stop mal oloja Ts Notes e Variables to be configured can only be changed when no write protection is set e Grey fields can be altered e Padr Address range 0 250 e D ID number BCD e MED Medium e VIF3 Unit and decimal power of the meter reading MSB 0 e Count Pulse count 5 bytes binary Count6 is always OOh e Meter denominator impulse value range 1 255 each e Miscellaneous fields MAN and GEN are ignored e ID MAN GEN and MED are coded as in the fixed header of the variable data structure from EN
9. otes 1 Please press first the button Connect to meter after connecting a new M Bus device Afterwards all sheets are refreshed 1 Examples for configuration of pulse increment and unit e Water meter with counter 45120 and 1 Pulse 10 Choice 1 Unit 101 Multiplicator 1 1 Counter 4512 x10 l Choice 2 Unit 11 Multiplicator 10 1 Counter 45120 x 11 e Electricity meter with counter 78346 kWh and 64 pulses kWh Choice Unit 1kWh Multiplicator 1 64 Counter 78346 x 1kWh e Electricity meter with counter 112 345 kWh and 1000 pulses kWh Choice Unit 1Wh Multiplicator 1 1 Counter 1123454 x 0 001Wh PadPuls M1 User Manual 26 09 01 Version 1 3 Zs 5 GmbH Stettiner Str 38 D 33106 Paderborn 4 M Bus Telegrams 1 General e Communications according to EN1434 3 e Transmission rates 300 2400 and 9600 Bd with auto baud detect e Primary and secondary addressing with wild cards SND_NKE E5 SND_UD E5 REQ_UD2 RSP_UD is supported 2 Definitions e All values are specified in hexadecimal e Empty fields in the Contents line are variable e Index 1 designates the least significant byte in fields containing several bytes 3 RSP UD Telegram sel gt Ts Ta fs 7 e wl ulels mtl se I e o Inf ale mt BE BR 7 BR RT DT DR DR J T HERE HE Verse oo or a Notes e Manufacturer MAN REL 48AC e Generation GEN at th
10. readout U a EW GmbH Stettiner Str 38 D 33106 Paderborn identical to the baudrate of the M Bus device see New M Bus Baudrate The PadPuls M1 supports the baudrates 300 2400 and 9600Bd allows reprogramming the baudrate of the M Bus device The new baudrate is sent to the M Bus device after a change in the appropriate selection box If the M Bus slave accepts this command it acknowledges the telegram with the single character BES for hexadecimal notation using the old baudrate Afterwards the device switches to the new baudrate This button is not needed for the PadPuls M1 since it automatically detects the baudrate used by the master is the primary address of the connected M Bus slave In a direct connection with only one slave you can use the broadcast address 254 Using this address every M Bus device must answer regardless of its own address is used to request data from the slave The type of device is then automatically recognized The items Manufact Generation Bus State will then be refreshed New sheets are generated depending on manufacturer and type of the M Bus device In case of PadPuls M1 a sheet labelled with PadPuls M1 appears is an item that shows the 3 letter manufacturer code after successful reading Connect to meter The item is read only shows the software revision of the firmware of the connected M Bus device The item is read only shows the type
11. tical mode Baudrate 2400 Manufact PEL ee joo HERENENERENE New M Bus 200 Baudrate 240 Eee Autom readout Connect to meter Erase log C 45 05 Ge Be B BE Be BE HE L Exit j _ few Summary of supported meters 0 A 1 This sheet shows some photos of supported M Bus devices from the product range of the Relay GmbH the PadMess GmbH and further manufacturer Here are also links to the Internet page from which the current version of the program can be downloaded and to the email address for criticism and suggestions to the program The lower third of this card is likewise visible in every other card Here the following input fields and buttons are always attainable COM Port is the serial port of the PC to which the M Bus level converter is connected The selected port will be saved in an INI file and will be restored on startup Therefore the COM Port has to be configured only once Baudrate ist the transmission speed of the serial port of the PC used for parameterization Possible selections for this used M Bus baudrate are 300 2400 or 9600 baud Attention Baudrates of more than 2400 baud are not supported by all M Bus level converters which are available on the market The selected baudrate must be 6 26 09 01 Version 1 3 PadPuls M1 User Manual New M Bus Baudrate M Bus Address Connect to meter Manufact Generation Type M Bus State ZVEI optical mode Autom
12. um 3V model 2 3AA 1700mAh max 1 5mA 1 unit load no battery loading 26 09 01 Version 1 3 PadPuls M1 User Manual u gt EW GmbH Stettiner Str 38 D 33106 Paderborn Battery operation Max 13uA at 25 C Max 15uA at 60 C additionally 3uA with continuously closed contact Battery service life gt 9 5 years at 25 C In battery operation gt 7 5 years at 60 C Max 50 million impulses per annum each Service life minus 10 with additional 30 million impulses per annum M Bus physical characteristics M Bus quiescent current typ 1 25 mA max 1 5mA 1 unit load Space 0 bit current quiescent current typ 13 mA M Bus interface TI TSS721 with 2 x 215Q protection resistors PadPuls M1 User Manual 26 09 01 Version 1 3 Zs 5 GmbH Stettiner Str 38 D 33106 Paderborn Notizen 26 09 01 Version 1 3 PadPuls M1 User Manual
13. ut fields and buttons have an underlined letter The function can be activated by simultaneous pressing of the keys ALT and the respective letter Within dialogs the cursor can be moved with the keys TAB or SHIFT TAB forwards and back SPACE activates or deactivates selection boxes Multiple selection boxes arrow at the right edge can be activated with U The user then selects an entry with and 1 By pressing RETURN the selected entry is taken over With ESC the selection box is left without transfer The program is arranged as a sheet system The sheet Info contains general options of the communication with the M Bus device to be configured In this sheet the user can select the serial port of the PC the baudrate of the PC the baudrate of the M Bus device and the M Bus primary address which is used for communication After a successful connection with the M Bus device further manufacturer information is shown in the sheet Info and additional device specific sheets are displayed PadPuls M1 User Manual 26 09 01 Version 1 3 5 GmbH Stettiner Str 38 D 33106 Paderborn 3 3 Sheet Info fil RELAY HBCONF M Bus Configuration 1_ 40 Current information about M Bus and software updates can be found on our internet site Please send your questions and comments to our EMAIL address WA RELAY DE is mailto intotaRe Lay DE COM Part com eine 254 Generation iz T ZWEI op
14. yh EW GmbH Stettiner Str 38 D 33106 Paderborn 3 Parameterization using MBCONF The configuration of the device must be adapted by the customer to the respective installation We include the software MBCONF with delivery You can get the old software PADCON for MS DOS or MS Windows 3 1 systems from our web page www relay de 3 1 Installation The software MBCONF for configuration of the pulse adaptor is a 32 bit application which can be executed on IBM PC compatible computers under the operating systems Windows 95 98 NT 4 0 The desktop PC or laptop must have a free serial RS232C interface to connect the M Bus level converter The PadPuls M1 to be parameterized must be connected directly i e as only M Bus device to the M Bus output of the level converter Please start the file MBCONF_SETUP EXE from Windows Explorer or via Start Execute to install the software from version 1 40 up Subsequently you select the language of the installation procedure The setup software can create a program group and a link on the desktop on demand You can then execute both versions for German and English language either from start menu or desktop 3 2 Operation After program start the user operates the software according to the Windows conventions with the mouse or the keyboard If you stay with the mouse on a button or an input field then a hint to its function appears Light grey fields and boxes are not capable for editing All inp