Home
System manual Medis 2MP2-1NT-MGD 221
Contents
1. System Manual MeDis 2MP2 1NT MGD 221 MkIl 102 Display user manual Advanced geometry Linearity amp S correction Vertical S corr Advanced geometry Advanced bowing amp skewing Horizontal bowing right Advanced geometry Advanced bowing amp skewing Horizontal skewing left Advanced geometry Advanced bowing amp skewing Horizontal skewing right System Manual MeDis 2MP2 1NT MGD 221 MKII 103 Display user manual Focus Static focus Adjust Static focus to obtain an image as sharp as possible in the center Focus zone You can adjust the focus in 9 independent zones Turn the control knob to obtain an image as sharp as possible in the selected zone Press the control knob to switch to the next zone ALC optional Ambient Light Compensation ALC is an optional system that automatically adapts the display contrast and brightness level to the ambient light in the room The system has to be adjusted by setting the contrast and brightness in the darkest ambient light conditions the user works and then repeating this in the brightest conditions To adjust the ALC system proceed as follows 1 Dim the light in the room to create the darkest ambient light condition the user normally works in 2 Enterthe Minimum illuminance menu 3 Select Measure
2. tS Ports COM amp LPT fr Sound video and game controllers System devices Universal Serial Bus controllers Figure 7 Windows 2000 Display Adapters Window In the example above there was one BarcoMed 2MP2 installed in the system and NO 3 party VGA card The first Cirrus Logic Laguna 5465 shown is the primary head on the BarcoMed 2MP2 Use this device first when installing the BarcoMed 2MP2 driver The second Cirrus Logic Laguna 5465 shown is is the secondary head on the BarcoMed 2MP2 and must be installed second 10 Double Click on the first display adapter to open its properties page 11 Select the Driver tab and click the Update Driver button The Upgrade Device Driver Wizard will start Click Next to continue Select the Radio Button beside Display a list of the known drivers for this device so that can choose a specific driver Click Next 13 In the Select a Device Driver page of the wizard click Have Disk Insert your driver disk or browse to the location of your driver and Click OK Select 2MP2 in the Select a Device Driver window Click Next 14 An Update Driver Warning dialog box may appear saying Installing this device driver is not recommended because Windows cannot verify that it is compatible with your hardware If the driver is not compatible your hardware will 12 System M
3. e 13 Supported Resolutions For Each Head of the 2 2 13 2MP1NT Product Overview sssssssssssese eene enne 15 15 Features of the BarcoMed 2 1 15 Minimum System Requirements ssssesee en 15 Supported Resolutions eee nectit centi eee denen 15 HARDWARE INSTALLATION eene enn emen errem 17 Familiarizing Yourself With the BarcoMed 2MP2 or BarcoMed 2MP1NT Imaging Board 2 2 ie ate esum Jumper Location Using the VGA Capabilities of the BarcoMed 2MP2 or BarcoMed 2MPINT enne 17 Standard Jumper Functions sssssssssssseseeeeeeene ens 18 Installing the BarcoMed 2MP2 or 2MP1NT Graphics Controller 19 Running Multiple BarcoMed 2MP Boards in a Single Host 20 Display installation c etia cetero dee ct el nodu i e rada ias 21 Display installation itsik eiie Iii deep eerte eo Ente 23 Scuprrrcc ES 23 Placing and configuring the 24 Connection of the video cables 24 Connection of the Remote cables 25 Power up the system Poe
4. seem 83 The memory System ro tro ER DR CD ERG ER 83 Image conformity and consistency 83 Calibration and adjustments 83 Power saving System eeepc a Ree EB eee nes 84 Versions and options 84 Abo t the manuals aaia a ea Hisce 84 Iristallationi en Sere eo det 85 Precautions eiea DC 85 The package contents 85 Controls and cohriectors 4 icet esent rts dateien sirena Ro pre necis 86 Signal connection iei icit entere pe en ie e cede desde eite 87 a Connection of video signals essen 87 b Connection of data signals ssem 88 Connection of optical sensor 88 d Connection of 89 Positioning the display 89 Important considerations sese eem nennen 90 Operation User controls enormen etes desee 91 Switching on MOM arenon p eon Heo ATE eU ede 91 Contrast and brightness 1 92 Viewing Status information esse emen 94 Other adjustments 1 ioni e eni oe deen tense
5. rmn ee tdi ie eben te bons 64 Begin Work Day cccecceccceeeeeceeeeeeeeecaeceseesenaaeeeeseeeaaeaeeeeseseeaeeeeseeseaaees 64 End Work Day efe be ere tie ix denen 64 Screen Saver During Work Day sss 64 Available Savers 12 cierre ederent Heidi deter ede side Eee nee eie 65 SIME 65 DPMS Settings After Work Day seem 65 Amount of Time in each DPMS State 65 Monitor Settings sue e 66 Use As Logon Screen Saver sss 66 System Manual MeDis 2MP2 1NT MGD 221 MKII Installing the BarcoMetheus DPMS Screen 66 Getting started with the BarcoMetheus DPMS Screen Saver 67 Using the BarcoMetheus DPMS Screen 68 Uninstalling DPMS idee sentidos 73 MediCal software installation and 75 MediCal software installation eeseee em 77 Optical sensor connection 77 Using MediGal eerie re te e re ee vt abet Hed 77 Display user Manual i aaae idda caved du cidit a rede A e Cua dna cee na rods 79 Introductio e tlie 83 II I 83 Resolution and bandwidths
6. Display Properties Themes Desktop Screen Saver Appearance Settings Drag the monitor icons to match the physical arrangement of your monitors Display 1 Default Monitor on BarcoMed 2MP1NT Screen resolution Color quality e s Low 8 bit 1200 by 1600 pixels Use this device as the primary monitor Extend my Windows desktop onto this monitor Tesi Figure 14 Windows XP Display Properties Settings Tab after the BarcoMed 2MP1NT drivers have been installed and the resolution set Note The system shown above has one BarcoMed 2MP1NT Imaging Board installed with VGA enabled Your configuration may be different System Manual MeDis 2MP2 1NT MGD 221 MkIl 50 BarcoMed software driver installation BARCO METHEUS CONFIGURATION TAB Introduction After the BarcoMed 2MP Windows Display Driver is installed a new Display Properties tab is available for configuring special features of the BarcoMed 2MP board Please note that you must have logged on to Windows using an account with administrator privileges in order to use the BARCO Metheus Control Panel to change any display settings 1 Open the Display Properties Control Panel by right clicking on the desktop then select Properties 2 Under Windows NT 4 0 Click on the BARCO Metheus Configuration Tab see figure 15 below Under Windows 2000 click on Settings tab Double click on the rectangle that represents the BarcoMed 2MP
7. The Windows Installer will ask if you are sure you want to remove this program click Yes When the Windows Installer has finished removing the program click Close to exit the Add Remove Program Control Panel Close the Control Panel window System Manual MeDis 2MP2 1NT MGD 221 MKII 74 MEDICAL SOFTWARE INSTALLATION AND USAGE MediCal software installation and usage This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 76 MediCal software installation and usage MEDICAL SOFTWARE INSTALLATION Install MediCal on the PC Follow the instructions from the MediCal User Guide Important Do not forget you have to have Administrator privileges to install or uninstall MediCal OPTICAL SENSOR CONNECTION If you are using an X Rite DTP92 sensor for conformity calibration and consistency check connect the sensor to one of the display s Sensor plugs or to a free PC COM port USING MEDICAL You can now use MediCal to configure the complete configuration and set up the Q A tasks Proceed as follows 1 Start MediCal If appropriate you can connect to MediCal Administrator 2 Set up the configuration in MediCal by using the Configuration Setup wizard 3 If necessary align the displays geometry settings 4 For all the displays in the system check if the DPMS setting is turned on Therefore right click on the display icon and select Properties from the drop dow
8. Follow all instructions for operation and use to an AC voltage as indicated at its back Using a lower voltage the apparatus will not be able to operate Using a higher voltage may damage the apparatus If you are not sure of the type of power supplied consult the power company Do not overload wall outlets and extension cords as this may result in fire or electric shock Mains lead protection U S Power cord Supply cords should be routed so that they are notlikely to be walked upon or pinched by items placed upon or against them paying particular attention to cords at plugs and receptacles Water and moisture Never expose the apparatus to rain or moisture Never use the apparatus near water e g near a bathtub washbasin swimming pool kitchen sink laundry tub or in a wet basement Ventilation Do not cover or block the ventilation openings in the cover of the set When installing the apparatus in a cupboard or another closed location heed the necessary space between the set and the sides of the cupboard Installation Place the apparatus on a flat solid and stable surface that can bear the weight of at least 3 monitors If you use an unstable cart or stand the set may fall causing serious injury to a child or adult and serious damage to the equipment More warnings in the Installation chapter 82 Display user manual INTRODUCTION Overview Resolution and bandwidths The
9. Display address In multi head systems multiple displays controlled by one system each display must have a different address With this setting you can set the display address from 1 to 16 User controls disable With this setting you can enable or disable the user controls When OFF the user controls are not disabled and the user can activate and use the OSD menus When ON the user controls are disabled After quitting the OSD the user will no longer be able to activate the OSD To activate the OSD again when the user controls are disabled use the following code 1 Tum the control knob 3 times counter clockwise seen from the rear 2 Turn the control knob 3 times clockwise 3 Turn the control knob 3 times counter clockwise Note This should be done in quite a short time Saving the settings The settings are automatically saved after changing them System Manual MeDis 2MP2 1NT MGD 221 MKII 97 Display user manual Adjustments a How to make the adjustments 1 Turn the control knob at the rear from left to right or from right to left to activate the On Screen Display OSD main menu 2 Inthe main menu turn the control knob to select Adjustments 3 Press the control knob for a few seconds The Adjustments menu appears Note If you press only shortly the message Service protected appears 4 Turn the control knob to select the category of adjustments you want to make 5 Press the control knob sh
10. System Manual MeDis 2MP2 1NT MGD 221 MKII 45 BarcoMed software driver installation Display Properties Themes Desktop Screen Saver Drag the monitor icons to match the physical arrangement of your monitors 2088 4 Default Monitor on BarcoMed 2M P2 Screen resolution Color quality e s Low 8 bit 1200 by 1600 pixels Use this device as the primary monitor Extend my Windows desktop onto this monitor Identify Troubleshoot Advanced Figure 12 Windows XP Display Properties Settings Tab after the BarcoMed 2MP2 drivers have been installed and the resolution set Note The system shown above had two 2MP2s installed and no 3 party VGA Card Your configuration may be different System Manual MeDis 2MP2 1NT MGD 221 MkIl 46 BarcoMed software driver installation Installing the Windows XP driver for the BarcoMed 2MP1NT SPECIAL NOTE Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board s connect the monitor s to the card s and turn the monitor s on Refer to the Hardware Installation Guide that came with your BarcoMed Imaging Board s for instructions on installing the BarcoMed Imaging Board s and connecting them to the monitor s To install the BarcoMed 2MP1NT Windows XP Display Driver follow these steps 1 10 Install the BarcoMed 2MP1NT adapter s into the machine Refer to the hardware installation manual for more informat
11. 2 teet ope mot epa ee 53 Palette Mode nce 53 UserModifiable Color Palette sss 53 Static Gray Palette including standard system colors 53 Static Gray Palette with NO system colors 54 Drawitig Modes ripe aided i DR b sese tieu 55 Enable DirectDraw elati neret th dene sten 55 Enable Dithering 2 eorr terrre teer ttt re enero rec 55 Monitor Configuration 55 Languages supported 56 Barco Metheus Hardware Configuration Tab 57 Introduction 2 once eire ERE cete eee da ipee ein e 57 Using The BARCO Metheus Hardware Configuration Tab 59 DEV CE a teni a 59 PCL Information rene RI 60 Firmware Information 60 Barco Metheus DPMS OwWerview eese emen 63 itol p ieee 63 BarcoMetheus DPMS Screen Saver 64 el eens eee de Fee E 64 NI P 64 pp P P 64 Work Schedule
12. Board s and connecting them to the monitor s To install the BarcoMed 2MP2 Windows XP Display Driver follow these steps 1 10 Install the BarcoMed 2MP2 adapter s into the machine Refer to the hardware installation manual for more information Boot the machine and log on using an account with administrative privileges Windows XP will automatically load the drivers for the Cirrus Logic Laguna 5465 the chipset used on the BarcoMed 2MP2 imaging board To install the BarcoMed 2MP2 drivers right click on an empty space of the desktop and select Properties Select the Settings tab see Figure 11 on the next page For each BarcoMed 2MP2 imaging board installed there will be two rectangles representing the two heads supported by each Barco 2MP2 to select from Double click on the rectangle that represents the first head of the BarcoMed 2MP2 Imaging Board you are working with to open its properties page Select the Adapter tab and click the Properties button The BarcoMed 2MP2 Properties page will open Select the Driver tab and click the Update Driver button The Hardware Update Wizard will start Select the Radio Button beside Install from a list or specified location Advanced Click Next On the Please choose your search and installation options page of the Hardware Update Wizard select the Radio Button beside
13. installed Click on OK 11 Close the Display Type dialogue box 12 Close the Display Properties dialogue box 13 You will be asked if you want to restart your computer Select Yes 14 When the system comes back up select NT Version 4 00 VGA Mode Log on using an account with administrator privileges 15 The Invalid Display Settings dialog box will appear with the following message A new graphics driver has been installed The default display resolution from the driver has been temporarily used by the system Please use the Display option in the Windows NT Control Panel to select your preferred display resolution Click OK System Manual MeDis 2MP2 1NT MGD 221 MKII 30 BarcoMed software driver installation 16 17 18 19 20 21 22 The Display Properties dialog box will appear See figure 6 on the next page Under the Settings tab select List all Modes Select the desired resolution from the list For example 1200x1600x256 at 75Hz Click OK NOTE If you have multiple single headed imaging boards 2MP1s amp 2MP1NTs the resolution will be the size of your virtual desktop For example if you have 2 displays running at 1200 1600 256 at 75Hz you would select the following resolution 2400x1600x256 at 75Hz Select the Test button and click on OK to test the display You will be asked if it display
14. tab See figures 20 21 and 22 2 Select the BarcoMetheus DPMS Screen Saver in the Screen Saver drop down menu if it is not already selected 3 Click on the Settings button The Barco Metheus DPMS Screen Saver Control Panel will open See figure 23 4 Use the default schemes by selecting one of the three default schemes Click OK Then Click OK again Note If you make any changes to any of the settings of one of the three default schemes the Current Scheme field will blank and you MUST SAVE your changes by clicking on the Save As button When you click on the Save As button the name of the last scheme you used will be automatically displayed you can then choose to use that scheme name or enter a new name After the you have saved the scheme then click OK and the new scheme will be in effect System Manual MeDis 2MP2 1NT MGD 221 MKII 68 BarcoMed software driver installation Display Properties Figure 20 Windows NT 4 0 Screen Saver Tab System Manual MeDis 2MP2 1NT MGD 221 MKII 69 BarcoMed software driver installation Display ee HEI Background Screen Saver Appearance Web Effects Settings BARCO For Maximum Life r Screen Saver Barco Matheus DPMS Settings Preview Password protected Wait 15 4 minutes r Energy saving features of monitor adjust the power settings for your monitor
15. Highest 32 bit v E40 by 480 pixels um Use this device as the primary monitor Extend my Windows desktop onto this monitor Figure 11 Windows XP Display Properties Settings Tab before the BarcoMed 2MP2 drivers have been installed Note In the example above there were two BarcoMed 2MP2 installed in the system and NO 3 party VGA card The first rectangle 1 shown is the primary head on the BarcoMed 2MP2 Use this device first when installing the BarcoMed 2MP2 driver The second rectangle 2 shown is is the secondary head on the BarcoMed 2MP2 and must System Manual MeDis 2MP2 1NT MGD 221 MKII 44 BarcoMed software driver installation be installed only after you have rebooted and set the resolution for the first head Rectangles 3 amp 4 represent the two heads on the second BarcoMed 2MP2 board Setting the resolution of your high resolution monitor 1 a Reboot in VGA Mode and login using an account with administrative privileges If you do not reboot in VGA Mode Windows XP may select a resolution that is not compatible with your high resolution monitor and you will then need to reboot in VGA Mode To set the resolution for your monitor open the Display Properties Control Panel by right clicking on the desktop Select Properties see Figure 12 on the next page For each BarcoMed 2MP2 imaging board installed there will two rectangles rep
16. MGD 221 can be delivered with the following options Southern Hemisphere Compensation and Ambient Light Compensation ALC The MediCal software and the X Rite DTP92 sensor are not delivered with the display MediCal can be ordered separately About the manuals This guide is meant for people who want to install and use the MGD 221 display as well as people who need to install and adjust the display The chapter Advanced Adjustments is meant for trained engineers only because it describes actions and procedures that require a technical skill to be performed properly The use of the software MediCal is described in the MediCal User s Manual System Manual MeDis 2MP2 1NT MGD 221 MKII 84 Display user manual INSTALLATION Precautions Keep your original packaging It is designed for this display and is the ideal protection during transport Do not lift the display all by yourself to avoid injury Avoid reflections in the picture tube to reduce eye strain Place the display on a strong and stable table or desk if used as desktop display Keep the display away from heat sources and provide enough ventilation in case it is built in a rack or console Keep the display away from strong sources of magnetic fields Make sure the display and computer are both switched off before connecting the signals The package contents The MGD 221 display The accessory box in which you found this manual Notes The MGD 221
17. Manual MeDis 2MP2 1NT MGD 221 MKII 12 Imaging board installation PRODUCT OVERVIEWS 2MP2 Product Overview Introduction The BarcoMed 2MP2 Graphics Controller delivers a quality 1200 x 1600 pixel image with 256 simultaneous shades of gray for medical imaging applications Features of the BarcoMed 2MP2 Dual Head Configuration 1200 x 1600 resolution at 75 Hz 10 bit input DAC 4MB Video Memory VRAM Portrait or Landscape Mode 256 Simultaneous shades of gray from a Palette of 1024 Fully compatible with the BarcoMed 2MP1NT Hardware cursor Single slot PCI card Display Properties Control Panel to dynamically change display settings Control Panel support for the English U S Dutch German Japanese Korean Simplified Chinese and Traditional Chinese languages Minimum System Requirements PCI slot with no obstructions PCI 2 1 Compliant System VGA compatible high resolution displays or a separate VGA card and display NT 4 0 SP4 and above Windows 2000 SP1 and above or Windows XP Supported Resolutions For Each Head of the 2MP2 1600x1200 80 Hz 1280x1024 75 Hz 1200x1600 66 Hz System Manual MeDis 2MP2 1NT MGD 221 MKII 13 Imaging board installation e 1200x1600 Q 74 Hz e 1200x1600 75 Hz primary 1024x768 75 Hz 1024x1280 67 Hz 1024x1280 Q 70 Hz 800x600 75 Hz 640x480 75 HZ System Manual MeDis 2MP2 1NT MGD 221 MKII 14 Imaging board
18. This complies with the Windows standard interface method If you are unsure whether or not your application requires this Static Gray Palette including Standard System Colors mode contact your application provider Static Gray Palette with NO system colors This option sets the palette to be a static linear ramp of 256 shades of gray Therefore applications are denied the ability to dynamically change or allocate palette entries This prevents palette conflicts between applications which can cause image color values to appear distorted in the background application As shown in the picture below each of the 256 entries in the palette has an RGB value of i i i where i is the index from 0 to 255 palette entry 110 has RGB value of 110 110 110 0 255 es i If you wish to use a static gray palette we recommend using the Static Gray Palette including Standard System Colors option instead of this one This is due to the fact that some applications assume that the first and last 10 entries of the palette are the standard system colors In this palette mode these entries are made up from entries in the bottom or the top of the gray ramp Please note that dithering is not permitted while in this mode The Enable Dithering check box will be grayed out and dithering will be automatically disabled regardless of whether this check box is checked This complies with the Windows standard interface method If you are unsure whether or
19. a new scheme by modifying one of the three default schemes please do the following 1 Open the Display Properties Control Panel by right clicking on the desktop and then select the Screen Saver tab 2 Select the BarcoMetheus DPMS Screen Saver in the Screen Saver drop down menu if it is not already selected 3 Click on the Settings button The Barco Metheus DPMS Screen Saver Control Panel will open 4 Select one of the default schemes from the Current Scheme drop down menu System Manual MeDis 2MP2 1NT MGD 221 MkIl 72 BarcoMed software driver installation 10 11 12 Set the Work Schedule by setting the beginning and ending time of your workday for each day of the week Select the screen saver you wish use during the workday in the Screen Saver During Work Day section Select the amount of time you wish to spend in the Stand By and Suspend states after the workday has ended Please note that after the time specified has elapsed when you are in Stand By or Suspend you will automatically go into the Off state Select the amount of time it takes for your monitor to warm up If you have a Barco Medical Monitor select Barco Quick Start If you are using a non Barco monitor select the amount of time it takes your monitor to warm up via the Monitor Setting section Contact your monitor vendor for this warm up time On Barco CORONIS displays the I GUARD will stabilize the image wi
20. and vertical sync frequencies match the display specifications refer to the chapter Technical specifications For other problems please consult your technical service department System Manual MeDis 2MP2 1NT MGD 221 MKII 107 Display user manual APPENDIX A BACKGROUND INFORMATION Luminance Uniformity Correction A characteristic or limitation of every picture tube CRT is that the luminance decreases towards the edge of the screen surface The decrease is normally 20 to 30 This is caused by the shape of the picture tube Inside the CRT a so called electron gun shoots an electron beam towards the front the glass panel Because this panel is rather flat instead of having a spheric shape the electron beam has to travel a longer distance in the corners than in the center So the intensity is higher in the center This phenomenon is even increased by the irregular distribution of the phosphor and aluminium layer on the glass panel These tend to be thicker in the center BARCO has developed a special system called Luminance Uniformity Correction LUC that solves this problem The LUC system enhances the light output at the edges of the CRT so that the luminance there is the same as in the center The LUC system is calibrated in the factory From time to time it has to be re calibrated at the customer s site by means of the light sensor you use for normal color calibration The system can be calibrated and s
21. bus A typical example of this is the MediCal software that controls the display MediCal runs on a PC that is connected through the serial data bus This PC is not necessarily the same computer as the one that produces the video signals Unlike the video signals it is possible to daisy chain the serial data bus This means you can control different displays from one PC To connect the data signals 1 Connect one end of the serial data cable to one of the PC s COM ports If the COM port has a 25 pin connector you will need to use a D25 to D9 interface connector The cable and the interface connector are both supplied with MediCal 2 Connect the other end of the serial data cable to the Remote In connector 6 on the display s rear panel 3 For a daisy chain application connect the Remote Out connector 5 of the first display to the Remote In connector 6 of the next display c Connection of optical sensor To calibrate the display connect the optical sensor to the Sensor connector 1 at the front Notes The display supports the DTP 92 from X Rite as optical sensor The optical sensor is not supplied by BARCO Calibration can be done by means of MediCal only Always use the Ambient Light Shield during calibration At the front the sensor plug is located under the bezel System Manual MeDis 2MP2 1NT MGD 221 MKII 88 Display user manual d Connection of power 1 Power cord U
22. control knob to select Settings 3 Press and hold the control knob for a few seconds The Settings menu appears It displays each setting and its current status Note If you press only shortly the message Service protected appears 4 Turn the control knob to select the setting you want to change Press the control knob shortly to change the selected setting 6 For Display address you can change the setting by turning the control knob Return to the Settings menu by pressing the control knob For the other settings the new status instantly appears in the Settings menu oa System Manual MeDis 2MP2 1NT MGD 221 MKII 96 Display user manual Explanation of the Settings menu items LUC LUC is short for Luminance Uniformity Control When switched on the internal waveform processor will modulate the gain of the video amplifier so that the luminance is equal all over the screen within a tolerance of 5 The LUC system can be calibrated in the Adjustments menu see further ALC optional ALC is short for Ambient Light Compensation When this setting is on the contrast is controlled automatically depending on the ambient light measured by the ALC sensor 2 in the bezel Orbiter The Orbiter is an internal circuit that when switched on will slightly and slowly move the image to prevent pixel burn in Power save This setting can switch the automatic power saving system see Introduction chapter on or off
23. current setting for contrast and brightness This can be CAL The calibrated position This is the preferred setting in a controlled environment ALC For contrast only This indicates the Ambient Light Compensation ALC is on and contrast is controlled automatically depending on the ambient light ALC is an option empty When the main menu does not specify a setting contrast or brightness is manually set to a different value than the calibrated position To put contrast in calibrated position 1 Turn the control knob to select Contrast in the OSD main menu 2 Press the control knob shortly The contrast control menu appears 3 In the contrast control menu select Contrast CAL position and press the control knob shortly Contrast CAL position Manual contrast adjustment Exit Contrast control menu System Manual MeDis 2MP2 1NT MGD 221 MKII 92 Display user manual To control contrast manually 1 Turn the control knob to select Contrast in the OSD main menu 2 Press the control knob shortly The contrast control menu appears 3 In the contrast control menu select Manual contrast adjustment and press the control knob shortly The contrast scroll bar appears 4 Turn the control knob until you have reached the desired contrast 5 Press the control knob shortly or wait a few seconds to return to the contrast control menu 6 In the contrast control menu select Exit and press the control knob shortly to
24. display solution for medical applications MeDis 2MP2 can be a single head or multi head system MeDis 2MPNT1 is a single head system only MeDis comes with everything you need to set up a complete viewing system from video cables to displays The MeDis system can be delivered with MGD 221 MGD 2621P or MGD 2621L displays Contents of the package Please refer to the packing list on the outside of the MeDis box Please contact BARCO if the content of the package does not correspond to the list Other relevant documents MediCal Pro Installation and User Manual MeDis installation overview To install the MeDis system completely you have to follow these steps 1 Install the imaging board s in the PC Install and connect the displays to the PC Install the BarcoMed driver software Install the MediCal software Use MediCal Important installation considerations Preparations before installation 1 Make sure all equipment is switched off 2 n case you use a PCI extension box please install the box following the guidelines in its Installation or User s guide Considerations for the installation itself 1 This manual contains Hardware Installation Guidelines Install the board s in the PC or PCI extension box following these guidelines and precautions esp ESD protection System Manual MeDis 2MP2 1NT MGD 221 MKII 9 Introduction For MeDis 2MP2 only Take the following additional guidelines into ac
25. have administrator privileges tries to save a scheme using an existing default scheme name an error message is System Manual MeDis 2MP2 1NT MGD 221 MKII 67 BarcoMed software driver installation displayed saying you must have administrator rights to modify a default scheme If an administrator saves a scheme using an existing default scheme name a message is displayed to tell the user that the modification is saved to a default scheme and will be visible to all users If the administrator saves a scheme using a new name then the user is asked if the scheme should be saved as a default scheme or a private scheme Since there is no distinction between how a default scheme and a private scheme is displayed it is highly recommended that the user use a different naming convention to distinguish the two i e use DEFAULT for default schemes Private schemes are shared and visible to all users of the system Users who do not have administrator privileges can create modify or delete private schemes However only the user who created them can modify or delete them When the delete button is pressed the user is asked to confirm the delete request Using the BarcoMetheus DPMS Screen Saver To set up the Barco Metheus DPMS Screen Saver using one of the three default schemes please do the following 1 Open the Display Properties Control Panel by right clicking on an empty space of the desktop and then select the Screen Saver
26. in Hazardous locations Class equipment Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxyde FCC notice This equipment has been tested and found to comply with the limits of a class A digital device pursuant to Part 15 ofthe FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipmentis operated ina commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense A Power connection e Power cord Utilise a UL listed detachable power cord 3 wire type SJ or equivalent 18 AWG min rated 300 V min provided with a hospital grade type plug 5 15P configuration for 120V application or 6 15P for 240V application Warning This apparatus must be earthed Powerrequirements connectthe apparatus System Manual MeDis 2MP2 1NT MGD 221 MKII Read the safety and operating instructions before operating the apparatus Retain safety and operating instructions for future reference Adhere to all warnings on the apparatus and in the operating instructions manual
27. installation 2MP1NT Product Overview Introduction The BarcoMed 2MP1NT Graphics Controller delivers a quality 1200 x 1600 pixel image with 256 simultaneous shades of gray for medical imaging applications Features of the BarcoMed 2MP1NT Single Head Configuration 1200 x 1600 resolution at 75 Hz 10 bit input DAC 4 MB Video Memory VRAM Portrait or Landscape Mode 256 Simultaneous shades of gray from a Palette of 1024 Fully compatible with the BarcoMed 2MP2 Hardware cursor Single slot PCI card Display Properties Control Panel to dynamically change display settings Control Panel support for the English U S Dutch German Japanese Korean Simplified Chinese and Traditional Chinese languages Minimum System Requirements PCI slot with no obstructions PCI 2 1 Compliant System VGA compatible high resolution displays or a separate VGA card and display NT 4 0 SP4 and above Windows 2000 SP1 and above or Windows XP Supported Resolutions 1600x1200 80 Hz 1280x1024 75 Hz 1200x1600 66 Hz 1200x1600 74 Hz 1200x1600 75 Hz primary System Manual MeDis 2MP2 1NT MGD 221 MKII 15 Imaging board installation 1024x768 Q 75 Hz e 1024x1280 67 Hz 1024x1280 70 Hz 800x600 75 Hz 640x480 Q 75 HZ System Manual MeDis 2MP2 1NT MGD 221 MKII 16 Imaging board installation HARDWARE INSTALLATION Notice Wear a protective ESD strap during installation or handling of the board Electro
28. is disabled on the BarcoMed 2MP1NT and must NOT be used After installing the driver and rebooting this second device will no longer be listed under the Display adapters in the Computer Management Control Panel and will not be visible in the Windows 2000 Display Control Panel 10 11 12 13 Double Click on the first display adapter to open its properties page Select the Driver tab and click the Update Driver button The Upgrade Device Driver Wizard will start Click Next to continue Select the Radio Button beside Display a list of the known drivers for this device so that can choose a specific driver Click Next In the Select a Device Driver page of the wizard click Have Disk Insert your driver disk or browse to the location of your driver and Click OK Select 2MP1NT in the Select a Device Driver window Click Next System Manual MeDis 2MP2 1NT MGD 221 MKII 39 BarcoMed software driver installation 14 An Update Driver Warning dialog box may appear saying Installing this device driver is not recommended because Windows cannot verify that it is compatible with your hardware If the driver is not compatible your hardware will not work correctly and your computer may become unstable or stop working completely Do you want to continue installing this driver Click Yes 15 A Start Device Driver Installation dialog box will appear C
29. is not running VGA the device may not be enabled yet To enable the device check the Extend my Windows desktop into this monitor checkbox Click the Apply button Click on the Advanced Button Select the Adapter tab and then click on the List All Modes button Select the resolution and refresh rate that your monitor supports from the dialog box and click OK Click OK on the System Manual MeDis 2MP2 1NT MGD 221 MKII 40 BarcoMed software driver installation bottom of the Adapter Control Panel If the OK button on the bottom of the Adapter Control Panel is not visible press the Tab Key once and then press Enter 6 Click OK in the Windows will now apply your new desktop settings dialog box Your high resolution display s should now synchronize and display the Windows desktop 7 Click Yes when asked Your desktop has been reconfigured Do you want to keep these settings Repeat steps 1 6 for each monitor on all the BarcoMed Imaging Boards installed in your system You will need to extend your desktop to each additional monitor connected to a BarcoMed 2MP1NT prior to setting its resolution 8 When you have set the resolution for all of your high resolution monitors restart your computer and boot normally Display Properties L2 x1 Background Screen Saver Appearance Web Effects Settings Drag the monitor icons to match the physical arrangement of y
30. must become active is set in the PC s display properties System Manual MeDis 2MP2 1NT MGD 221 MKII 109 Display user manual APPENDIX B TECHNICAL SPECIFICATIONS Picture tube Faceplate transmission No Panel 34 AR panel 3096 Faceplate type AR panel or No Panel Image representation portrait Phosphor B4 L8 Light output Calibrated 215 Cd m Resolution Max adress pixels 1280 Max adress lines 1600 Scanning systems Horizontal scanning Multi sync controller controlled VGA boot range 30 35 kHz Normal operation range 80 140 kHz Minimum blanking 2 4 s Storable scan frequencies 4 Prealigned scans 1 Vertical scanning Minimum frequency 48 Hz Maximum frequency 150 Hz Minimum blanking 250 s after leading edge Geometry Nominal size 4 3 ratio 300mm x 400mm Nominal size 4 5 ratio 304mm x 380mm Inputs Video BNC connectors 75 Ohm Nominal level 0 7 Vpp Sync BNC connectors 75 Ohm Nominal level 0 5 Vpp Communication inputs outputs RS232 9 pin sub D connector Baudrate 9600 Power supply Voltage 100 240 V 10 Frequency 50 60 Hz Current 2 3 A Environmental Temperature range C Storage 20 65 Operation 0 45 Within specs 15 30 Altitude storage 25 000 ft operational 10 000 ft Humidity relative 95 max non condensing Weight No Panel version Packed 55 9 kg Unpacked 37 4 kg Dimensions packing H x W x D 788
31. not System Manual MeDis 2MP2 1NT MGD 221 MKII 54 BarcoMed software driver installation your application requires this Static Gray Palette with NO System colors mode contact your application provider Drawing Modes You can choose one or both of the following Drawing Modes Enable DirectDraw This option allows the user to enable or disable DirectDraw DirectDraw is a software interface that provides direct access to display devices while maintaining compatibility with the Windows graphics device interface GDI DirectDraw provides a device independent way for applications to gain access to the hardware features of specific display devices If you enable DirectDraw your application will have the choice of using DirectDraw or GDI If you disable DirectDraw your application will use GDI instead of DirectDraw Please note that in any case your application can always use BarcoMed driver functions i e WinBarco or other graphics extensions such as OpenGL Enable Dithering This option allows the user to enable or disable dithering Dithering is a technique for increasing the perceived range of colors in an image at the cost of spatial resolution Adjacent pixels are assigned differing color values when viewed from a distance these colors seem to blend into a single intermediate color The technique is similar to the half toning used in black and white publications to achieve shades of gray Please note that this option i
32. return to the main menu Alternatively you can just wait a few seconds and the OSD returns to the previous menu automatically To put brightness in calibrated position Contrast scroll bar The short stroke in the bar indicates c the calibrated position the long stroke indicates the current setting 1 Turn the control knob to select Brightness in the OSD main menu 2 Press the control knob shortly The brightness control menu appears 3 In the brightness control menu select Brightness CAL position and press the control knob shortly Brightness Brightness CAL position Manual Brightness adjustment Exit Brightness control menu To control brightness manually 1 Turn the control knob to select Brightness in the OSD main menu 2 Press the control knob shortly The brightness control menu appears 3 In the brightness control menu select Manual brightness adjustment and press the control knob shortly The brightness scroll bar appears Brightness scroll bar The short stroke in the bar E indicates the calibrated position the long stroke indicates the current setting System Manual MeDis 2MP2 1NT MGD 221 MKII 93 Display user manual 4 Turn the control knob until you have reached the desired brightness 5 Press the control knob shortly or wait a few seconds to return to the brightness control menu 6 In the brightness control menu select Exit and press the control knob shortly to return to the main me
33. the work day the user can specify that the monitor first go through two other DPMS states before going into Off state These two other states are Stand By and Suspend The user can specify how much time should be spent in each state in the Amount of Time in each DPMS Power State section A valuable feature of the Barco Metheus DPMS Screen Saver is that it will automatically ensure that CRT based monitors are warmed up for the start of the work day All CRT based monitors require some warm up time before they are at full performance On Barco CORONIS displays the I GUARD will stabilize the image within a few seconds after the monitor returns to the active state thus eliminating the need for a warm up period at the beginning of the workday On CRT based monitors such as the Barco MGD series a regular screen saver can be invoked during user inactivity during the workday This regular Screen saver and its settings can be chosen from the Screen Saver During Work Day section We recommend using an all black screen saver such as the Barco Metheus Blank Screen saver for the longest phosphor life On LCD based monitors such as the Barco CORONIS displays it is not necessary to invoke a screen saver as there is no CRT phosphor to preserve However one can extend the life of the backlight in the LCD monitor in addition to realizing great power savings during period of user inactivity by using DPMS to quickly enter the Off state We recom
34. to bring up its property page Click on the BARCO Metheus Configuration tab see figure 16 on the next page Under Windows XP click on Settings tab Double click on the rectangle that represents the BarcoMed 2MP to bring up its property page Click on the BARCO Metheus Configuration tab see figure 17 on the next page Display Properties 27x Background Screen Saver Appearance G Barco Metheus Hardware Configuration Settings BARCO Metheus Configuration http www barcomedical com Status Graphics Board BarcoMed 2MP2H Driver Version 51 00 Resolution 1200 x 1600 75 Hz Palette Mode Static Gray Palette including standard system colors Static Gray Palette with NO system colors Drawing Modes Iv Enable Direct Draw Iv Enable Dithering Monitor Configuration 7 Two monitors single row Cone Figure 15 Configuration Tab under Windows NT 4 0 System Manual MeDis 2MP2 1NT MGD 221 MKII 51 BarcoMed software driver installation Default Monitor and BarcoMed 2MP2H Properties x Barco Metheus Hardware Configuration General 1 Adapter l Monitor 1 Troubleshooting l Color Management 9 BARCO Metheus Configuration BARGO http www barcomedical com m Status Graphics Board BarcoMed 2MP2H Driver Version 5 1 00 Resolution 1200 x 1600 75 Hz Palette Mode User Modifiable Color Pale
35. 1 shown is the primary head on the first BarcoMed 2MP1NT Use this device first when installing the BarcoMed 2MP1NTdriver The second rectangle 2 shown is disabled on the BarcoMed 2MP1NT and must NOT be used After installing the driver and rebooting this second device will not be visible in the Windows XP Display Control Panel and will no longer be listed under the Display adapters in the Computer Management System Manual MeDis 2MP2 1NT MGD 221 MkIl 48 BarcoMed software driver installation Control Panel Rectangles 3 and 4 represent the primary and disabled heads on the second BarcoMed 2MP1NT installed in this system Your configuration may be different Setting the resolution of your high resolution monitor 1 Reboot in VGA Mode and log on using an account with administrative privileges If you do not reboot in VGA Mode Windows XP may select a resolution that is not compatible with your high resolution monitor and you will then need to reboot in VGA Mode To set the resolution for you monitor right click on an empty space of the desktop and select Properties Select the Settings tab see Figure 14 on the next page If you are using a single BarcoMed 2MP1NT and no 3 party VGA card there will be only a single desktop to select from If you are using multiple 2MP1NT s select the rectangle that represents the BarcoMed 2MP1NT Imaging Board you are working with SPECIAL NOTE If the you are using the VGA c
36. B410025 02 March 2002 2002 BARCO NV All rights reserved BarcoView Theodoor Sevenslaan 106 8500 Kortrijk Belgium Phone 32 0 56 23 32 44 Fax 32 0 56 23 33 74 E mail sales medical gbarco com http www barcoview com BarcoView Inc 3059 Premiere Parkway Duluth Georgia 30097 USA Phone 1 678 475 8000 Fax 1 678 475 8100 E mail sales medical barco com http www barcoview com BarcoView LTD 16F 1 Cheng Loong Plaza 33 Min Sheng Road Section 1 Pan Chiao Taipei Hsien Taiwan R O C Phone 886 2 2957 8357 Fax 886 2 2957 4080 MeDis 2MP2 2MP1NT MGD 221 System Manual CONTENTS Introduction ostendens cnim Ui 9 Contents of the package Petre t rpg repe n anre 9 Other relevant documents 9 MeDis installation overview 9 Important installation considerations e 9 Preparations before installation sse 9 Considerations for the installation itself 9 Imaging board installation sees 11 Pr duct OVervIeWs ne Ree eer ERE He 13 2MP2 Product Overview eene eene entere eret 13 Introduction Ec CS 13 Features of the BarcoMed 2MP2 13 Minimum System Requirements
37. BARCO MGD 221 is a high resolution greyscale portrait display Its outstanding visual performance combining a 2 MegaPixel resolution with a high brightness makes it ideal for medical imaging and many other medical and scientific applications The MGD 221 is compatible with any AC power system worldwide and automatically synchronizes to a wide range of sync frequencies Its high speed video amplifier supports pixel clocks up to 250 MHz The memory system The internal memory system can contain the adjustments for 8 different scanning formats the so called scanning modes Each scanning format is characterized by its sync signals The display s internal micro controller continuously samples the connected sync signals and compares them to the scanning modes already stored in the memory If the connected signal has already been stored the micro controller adapts the image to the corresponding adjustment values in the memory and further adjustments are unnecessary Image conformity and consistency Image conformity and consistency are the keywords In our factory the MGD 221 displays are perfectly adjusted and calibrated before they are shipped to the customer Internal circuits like the TrueGrey amp and Automatic White Stability AWS systems ensure display consistency over time Conformity with the original image quality is guaranteed by the automatic calibration which can be done by means of an optical sensor connected to the Sensor co
38. Dis 2MP2 1 The video cables from the MeDis system are numbered You can find the number on a label on the cable The cable number must correspond to the head on the imaging board and the display it is connected to E g cable 1 must connect head 1 on the first imaging board to display 1 cable 2 must connect head 2 also on the first board to display 2 etc Plug in the D15 connector of the video cable into the connector of the imaging board as described in the BarcoMed installation guidelines Plug in the large coaxial connectors BNC of the video cable into the connectors of the display Plug in the cable connector marked with green plastic into the display connector marked Video Plug in the cable connector marked with black plastic into the display connector marked HS CS Plug in the cable connector marked with white plastic into the display connector marked VS Connection of the Remote cables Note One of the remote cables is packed inside the MediCal box 1 The Remote cables that come with MeDis are not numbered It does not matter which cable you connect to which display as long as you take the Remote inputs and outputs on the displays into account Take one of the remote cables from the MeDis system Plug in its D9 female connector into one of the PC s serial ports e g COM1 If the port has 25 pins use the D25 to D9 interface you find in the MediCal software box to connect the remote cable Pl
39. Don t search will choose the driver to install Click Next In the Select a Device Driver page of the wizard click Have Disk Insert your driver disk and select the correct device from the Copy manufacturer s files from drop down menu or browse to the location of your driver and Click Select 2MP2 in the Select a Device Driver window Click Next When Windows XP has begun installing the BarcoMed 2MP2 driver it will warn you that the software has not passed Windows System Manual MeDis 2MP2 1NT MGD 221 MKII 43 BarcoMed software driver installation Logo testing to verify its compatibility with Windows XP Click Continue Anyway to install the drivers 11 When the drivers are installed click Finish on the update driver wizard and close the properties page for the device If you are installing multiple BarcoMed boards you must reboot your system when asked and set the resolution of the first monitor controlled by the first BarcoMed 2MP2 You can then install the remaining adapters associated with all of the BarcoMed 2MP2 boards installed in your system Repeat steps 3 11 until you have installed all of the adapters Display Properties Themes Desktop Screen Saver Appearance Settings Drag the monitor icons to match the physical arrangement of your monitors Display 1 Default Monitor on Cirrus Logic Laguna 5465 Screen resolution Color quality
40. H Advanced Serial Number 142783 VGA Bios Version BIOS V1 3 Firmware Version V1 2 08 Jan 2001 14 12 12 Hardware Version 095 08844 00 Rev D Generate Report Update Device Cancel Enpi Figure 19 BARCO Metheus Hardware Configuration Tab under Windows 2000 and Windows XP Using The BARCO Metheus Hardware Configuration Tab Device Displays the current BarcoMed Imaging Board driver and the currently selected display resolution Identify Device This button is for BarcoView Metheus internal use only and is greyed out System Manual MeDis 2MP2 1NT MGD 221 MKII 59 BarcoMed software driver installation PCI Information Device ID Displays the device s PCI Device ID number Vendor ID Displays the device manufacturer s PCI Vendor ID number Subsystem ID Displays the device s PCI Subsystem ID number SubsystemVendorlD Displays the device s PCI Subsystem Vendor ID number VGA Status Displays whether the VGA capabilities of the BarcoMed board are enabled or disabled Firmware Information Product Name Displays the name of the BarcoMed imaging board installed in the selected PCI slot Serial Number Displays the serial number of the BarcoMed imaging board installed in the selected PCI slot VGA Bios Version Displays the VGA Bios version for the BarcoMed imaging board installed in the selected PCI slot Firmware Version Displays the firmware version for the BarcoMed imagin
41. Utilized Plug and Play 2MP2H BarcoView AURA Video Controller or Video Controller VGA Compatible 2MP2 Cirrus Logic Cirrus Logic Laguna 5465 Laguna 5465 2MP1NT Cirrus Logic Cirrus Logic Laguna 5465 Laguna 5465 2MP1 Imagine Number 9 Imagine Number 9 Series 128 If you have previously installed drivers for the BarcoMed Imaging Boards in your Windows XP System Windows XP should correctly identify the board by their correct BarcoMed name However while updating the drivers to a new version or reinstalling the current driver Windows XP may identify the BarcoMed Imaging Boards by their Video Chipset If you choose to install multiple types of BarcoMed Imaging Boards in your computer it is important to carefully note which PCI slot each board is in and then install the drivers for each type of board based on the PCI slot they are installed in If you are using the VGA Capabilities of a BarcoMed Imaging Board it is important to install the driver for this board and set its resolution first System Manual MeDis 2MP2 1NT MGD 221 MKII 42 BarcoMed software driver installation Installing the Windows XP driver for the BarcoMed 2MP2 SPECIAL NOTE Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board s connect the monitor s to the card s and turn the monitor s on Refer to the Hardware Installation Guide that came with your BarcoMed Imaging Board s for instructions on installing the BarcoMed Imaging
42. allation and install the device drivers in the same sequence that the boards are installed in the PCI slots When installing BarcoMed Imaging Boards for the first time in a Windows 2000 System Windows 2000 Plug and Play Software identifies the BarcoMed boards by the Video Chipset utilized on each boards The Table below shows the BarcoMed Board the Chip Set utilized by the board and the driver Windows 2000 Plug and Play selects for each imaging board Driver Selected by BarcoMed Windows 2000 Board Model Chip Set Utilized Plug and Play 2MP2H BarcoView AURA Video Controller or Video Controller VGA Compatible 2MP2 Cirrus Logic Cirrus Logic Laguna 5465 Laguna 5465 2MP1NT Cirrus Logic Cirrus Logic Laguna 5465 Laguna 5465 2MP1 Imagine Number 9 Imagine Number 9 Series 128 If you have previously installed drivers for the BarcoMed Imaging Boards in your Windows 2000 System Windows 2000 should correctly identify the board by their correct BarcoMed name However while updating the drivers to a new version or reinstalling the current driver Windows 2000 may identify the BarcoMed Imaging Boards by their Video Chipset If you choose to install multiple types of BarcoMed Imaging Boards in your computer it is important to carefully note which PCI slot each board is in and then install the drivers for each type of board based on the PCI slot they are installed in If you are using the VGA Capabilities of a BarcoMed Imaging Board it is imp
43. ally fill in the blanks using the information entered when Windows was installed on your system You may change this information if you wish We recommend that you install DPMS for all users of the computer Click Next to continue 7 The Setup Type page will now appear Choose Typical to install the default schemes with English names Choose Custom to install the default schemes with either Dutch or German names Currently the default schemes are not supported in the Japanese Korean and Chinese languages W e recommend that the users of these three languages install the English default schemes and then rename and save them into their language in the DPMS configuration screen Click Next to continue 8 The Ready to Install Program page will now appear click Install to install DPMS 9 When the Windows Installer has finished installing DPMS the Installshield Wizard Completed page will appear click Finish to exit the program Getting started with the BarcoMetheus DPMS Screen Saver The easiest way to get started is to select an existing Scheme and then modify it with your preferences Schemes are separated into two kinds DEFAULT global and PRIVATE personal Upon installation three default schemes are installed and no private schemes are installed Default schemes are visible to all users of the system However they can be modified only by users with administrator privileges If a user who does not
44. ambient light The display now stores the ambient light level that corresponds to the darkest condition 4 Select Contrast and set the display contrast to the desired level 5 Select Brightness and set the display brightness to the desired level 6 Exit the Minimum illuminance menu 7 Increase the light in the room to create the brightest ambient light condition the user normally works in 8 Enter the Maximum illuminance menu 9 Select Measure ambient light The display now stores the ambient light level that corresponds to the brightest condition 10 Select Contrast and set the display contrast to the desired level 11 Select Brightness and set the display brightness to the desired level 12 Exit the Maximum illuminance menu System Manual MeDis 2MP2 1NT MGD 221 MKII 104 Display user manual Luminance uniformity This menu allows you to calibrate the display including the Luminance Uniformity circuit Proceed as follows 1 Connect the X Rite DTP92 sensor and apply the black shield see chapter Installation 2 Follow the instructions on the screen Factory reset This function allows you to undo all adjustments you have made since the display left the factory Select Go ahead to restore the factory settings Select Exit to return to the previous menu without erasing the adjustments c How to save changes Proceed as follows 1 After having made the adjustments select Exit in each appea
45. anual MeDis 2MP2 1NT MGD 221 MKII 35 BarcoMed software driver installation not work correctly and your computer may become unstable or stop working completely Do you want to continue installing this driver Click Yes 15 A Start Device Driver Installation dialog box will appear Click Next 16 Windows will warn you that a digital signature was not found Click Yes to continue the installation 17 When the drivers are installed click Finish on the update driver wizard and close the properties page for the device Do NOT reboot your system when asked until you have installed all of the adapters associated with all of the BarcoMed 2MP2 boards installed in your system Repeat steps 11 17 until you have installed all of the adapters Setting the resolution of your high resolution monitor 1 Reboot in VGA Mode and log on using an account with administrative privileges If you do not reboot in VGA Mode Windows 2000 may select a resolution that is not compatible with your high resolution monitor and you will then need to reboot in VGA Mode 2 To set the resolution for your monitor open the Display Properties Control Panel by right clicking on the desktop then select Properties 3 Select the Settings tab see Figure 8 on the next page For each BarcoMed 2MP2 imaging board installed there will be two rectangles representing the two heads supported by each Barco 2MP2 to select
46. apabilities of your BarcoMed 2MP1NT Imaging Board the resolution for that board will still be set to a VGA resolution of 640 x 480 pixels If the BarcoMed 2MP1NT Imaging Board is not running VGA the device may not be enabled yet To enable the device check the Extend my Windows desktop into this monitor checkbox Click the Apply button Click on the Advanced Button Select the Adapter tab and then click on the List All Modes button Select the resolution and refresh rate that your monitor supports from the dialog box and click OK Click OK on the bottom of the Adapter Control Panel If the OK button on the bottom of the Adapter Control Panel is not visible press the Tab Key once and then press Enter Click OK in the Windows will now apply your new desktop settings dialog box Your high resolution display s should now synchronize and display the Windows desktop Click Yes when asked Your desktop has been reconfigured Do you want to keep these settings Repeat steps 1 7 for each monitor on all the BarcoMed Imaging Boards installed in your system You will need to extend your desktop to each additional monitor connected to a BarcoMed 2MP1NT prior to setting its resolution When you have set the resolution for all of your high resolution monitors restart your computer and boot normally System Manual MeDis 2MP2 1NT MGD 221 MKII 49 BarcoMed software driver installation
47. ated position Activity timeout This is the time expressed in seconds before the display interrupts the data communication with the computer e g during a computer session with MediCal if the computer does not respond anymore SH compensation optoinal Indicates if Southern Hemisphere compensation is switched on or off Note Southern Hemisphere compensation is an option If the option is not installed in the display this line does not appear in the menu Actual H frequency Actual V frequency These are the actual horizontal and vertical sync frequencies of the connected video signal They are measured constantly by the display Other adjustments The main menu items Settings and Adjustments are reserved for trained service staff and are therefore password protected System Manual MeDis 2MP2 1NT MGD 221 MKII 95 Display user manual ADVANCED SETTINGS AND ADJUST MENTS FOR SERVICE STAFF ONLY Important The functions and controls described in this chapter can have a serious impact on the performance of the display They should be touched by trained service staff only Settings SETTINGS INFORMATION LUC OFF ALC OFF Orbiter OFF Power save ON Display address User controls disable OFF Exit The Settings menu To change the settings 1 Turn the control knob at the rear from left to right or from right to left to activate the On Screen Display OSD main menu 2 Inthe main menu turn the
48. b Double click on the rectangle that represents the BarcoMed 2MP2H to bring up its property page Click on the BARCO Metheus Hardware Configuration tab see figure 19 on the next page Display Properties Background Screen Saver Appearance X9 BARCO Metheus ES Barco Metheus Hardware Configuration Plus Settings http Awww barcomedical com r Device jtd 4 Function PCI Information Device ID 1 Vendor ID 013CC Desce SubSystem ID 0 2 SubSystem endolD 041300 VGA Status Enabled Firmware Information Product Name 2MP2H Advanced Serial Number 123456 VGA Bios Version 05 V1 3 Firmware Version V1 2 08 Jan 2001 14 12 12 Hardware Version Mot Available Generate Report Update Device Cancel Apply Figure 18 BARCO Metheus Hardware Configuration Tab under Windows NT 4 0 System Manual MeDis 2MP2 1NT MGD 221 MKII 58 BarcoMed software driver installation Default Monitor and BarcoMed 2MP2H Properties 2 xi General Adapter Monitor Troubleshooting Color Management X9 BARCO Metheus Configuration X9 Barco Metheus Hardware Configuration BARCO 7 http www barcomedical com m Device Bus O Sloti3 FunctionO 4 PCI Information Device ID OxAFB1 Vendor ID 0x13CC dentin Device SubSystem ID 0 2 SubSystemVendorlD 0 13 VGA Status Enabled Firmware Information Product Name 2MP2
49. board at a time the process for installing the drivers for the BarcoMed imaging boards is identical regardless of which model you are using In addition to the device drivers for your BarcoMed imaging boards your BarcoMed Software CD also includes several additional tools They are The Barco Metheus Configuration Tab the Barco Metheus Hardware Configuration Tab and the Barco Metheus DPMS Screen Saver The Barco Metheus Configuration Tab and the Barco Metheus Hardware Configuration Tab are automatically installed with BarcoMed imaging board drivers The Barco Metheus Configuration Tab helps you manage the special features of your BarcoMed imaging boards The Barco Metheus Hardware Configuration Tab gathers information about the BarcoMed imaging boards and your system that is useful when diagnosing problems The Barco Metheus Hardware Configuration Tab can also be used to update the firmware on the AURA video chipset based BarcoMed imaging boards The Barco Metheus DPMS Display Power Management Signaling Screen Saver is an optional tool which must be installed separately The Barco Metheus DPMS Screen Saver allows the user to set power and monitor saving features for medical monitors driven by BarcoMed Imaging Boards At the end of the workday the monitor will enter certain DPMS states as requested by the imaging board This is accomplished through standardized signals between the monitor and imaging board Instructions for installing the Barco Met
50. can be part of a complete MeDis system consisting of the display itself an imaging board and software In that case the package contains a lot more items The contents of the package is then described in the manual of the complete system The ambient light shield inside the accessory box should always be used during conformity calibration with the X Rite DTP92 optical sensor System Manual MeDis 2MP2 1NT MGD 221 MKII 85 Display user manual Controls and connectors 1 2 3 4 5 6 7 8 9 A OONDU Optical sensor plug Ambient Light Compensation ALC sensor optional Green power LED Control knob combination of a push button and a turning knob The control knob is used for switching the power on off and selecting and performing functions in the OSD on screen display menu Remote RS 232 output Remote RS 232 input Video input Horizontal composite sync input Vertical sync input 10 Power input 11 Power button System Manual MeDis 2MP2 1NT MGD 221 MKII 86 Display user manual Signal connection a Connection of video signals The connected equipment must comply to all relevant safety demands Important The use of low quality video cables can distort the video signal and influence diagnosis 1 Check the impedance of the imaging board that produces the vide
51. click Power Power Cancel Apply Figure 21 Windows 2000 Screen Saver Tab System Manual MeDis 2MP2 1NT MGD 221 MKII 70 BarcoMed software driver installation Display Properties Themes Desktop Screen Saver Appearance Settings BRRCO For Maximum Life e Screen saver Barco Metheus DPMS v Mail 15 minutes On resume password protect Monitor power To adjust monitor power settings and save energy click Power Figure 22 Windows XP Screen Saver Tab System Manual MeDis 2MP2 1NT MGD 221 MKII 71 BarcoMed software driver installation Barco Metheus DPMS Display Saver 21x http barcomedical com Curent Scheme Default M F 8am 5pm z Delete Work Schedule Sun Mon Tue Wed Thu Fri Sat Begnwok so feo ao End Work Day H 17 09 f 17 09 17 00 17 09 17 00 Screen Saver During Work Day Available Screen Savers Rarco Metheus Blank Scree Settings DPMS Settings After Work Day Amount of Time in Each DPMS State Monitor Setting Time minutes Time Required for Your Monitor to Warm up Time in Stand By State 0 Barco Quick Start Time in Suspend State 0 m Additional Options Iv Use As Logon Screen Saver OK Cancel Help Figure 23 Barco Metheus DPMS Setting Control Panel To create
52. coMed board It may become necessary depending on how your PC s BIOS configures the PCI bus to switch your BNC display connections to achieve a linear desktop configuration Figure 3 The Video Outputs System Manual MeDis 2MP2 1NT MGD 221 MKII 20 DISPLAY INSTALLATION Display installation This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 22 Display installation DISPLAY INSTALLATION Examples An example of a correct set up of MeDis 2MP1NT is shown in figure 4 of MeDis 2MP2 in figure 5 The examples show set ups with MGD 221 displays but could as well have been with MGD 2621L or MGD 2621P mue Please take a good look at the illustrations and then read the rest of the text very carefully Remote cable Video cable so E NI BARCO MeDis r 2MP1NT installation Figure 4 Display 4 Display 3 Display 2 Display 1 rear view rear view rear view rear view Video cable 2 Video cable 1 TY VI 9g amp ot Video cable 4 Video cable 3 Fas Remote cable BARCO MeDis r 2MP2 PC quad head installation PCI board in PC top view Figure 5 System Manual MeDis 2MP2 1NT MGD 221 MKII 23 Display installation Placing and configuring the displays 1 The last part of thi
53. count 2 Each imaging board from the MeDis 2MP2 system contains 2 heads Accordingly the board is numbered with 2 digits E g the first board is numbered 1 2 meaning the board contains heads 1 and 2 The second board containing heads 3 and 4 if present is numbered 3 4 You can find these numbers on a label on the connector plate of the board In a multi board system the order in which you place the boards in the PC or extension box is not random They must be placed in ascending order taking the order number of the PCI slots into account E g board labeled 1 2 must be placed in PCI slot 4 board labeled 3 4 in Slot 5 etc In case the PCI slots are not numbered on the PC motherboard you can probably find the correct order in the main board s user manual If not it is hard to know which is the slot with the lowest number In that case you have to follow a try and error procedure If the boards are not placed in the correct slots you will notice the displays show their part of the complete image in an incorrect sequence after installation e g the leftmost part of the image is displayed by the rightmost display If this phenomenon occurs you will have to switch the boards and their video cables until the image is displayed in the correct sequence System Manual MeDis 2MP2 1NT MGD 221 MKII 10 IMAGING BOARD INSTALLATION Imaging board installation This page intentionally left blank System
54. ected to be used any more for that day After the workday the display is set to one of the DPMS states Stand By Suspend or Off by the imaging board during user inactivity Screen Saver During Work Day On CRT based monitors such as the Barco MGD series a regular screen saver can be invoked during user inactivity during the System Manual MeDis 2MP2 1NT MGD 221 MKII 64 BarcoMed software driver installation workday This regular screen saver and its settings can be chosen from the Screen Saver During Work Day section We recommend using an all black Screen saver such as the Barco Metheus Blank Screen saver for the longest phosphor life On LCD based monitors such as the Barco CORONIS displays it is not necessary to invoke a screen saver as there is no CRT phosphor to preserve However one can extend the life of the backlight in the LCD monitor in addition to realizing great power savings during period of user inactivity by quickly entering the Off state We recommend setting the work day to be as short as possible to get the maximum power savings on CORONIS displays Available Savers Lists the available screen savers Settings Changes settings for the selected screen saver DPMS Settings After Work Day If you have an imaging board that supports DPMS calls then you will be able to set the DPMS Settings for after the work day Otherwise a text box will be displayed tell you why DPMS functions are not availab
55. ed correctly If the test pattern displays correctly select Yes If not try selecting another mode from the List all Modes button In order to apply your changes type lt Ctrl gt Enter Restart your computer when prompted When your system comes back up select the NT Version 4 00 option NOT the VGA Mode option Log on as usual Continue on to the section BARCO Metheus Configuration Tab if you wish to further configure the driver System Manual MeDis 2MP2 1NT MGD 221 MKII 31 BarcoMed software driver installation Display Properties 20x BARCO Metheus Configuration Background Screen Saver Appearance Barco Metheus Hardware Configuration Plus Settings Color Palette _ p Desktop Area Less More 2400 by 1500 pixels Eont Size 34 Refresh Frequency mares misse m List All Modes Test Display Type Cancel Apply Figure 6 Windows NT 4 0 Display Control Panel Settings Tab Note In the system shown above there were two BarcoMed 2MP1NT imaging boards installed and no 3 party VGA card Your configuration may be different System Manual MeDis 2MP2 1NT MGD 221 MkIl 32 BarcoMed software driver installation Planning Your Barcomed Windows 2000 Installation Because of Windows 2000 s Plug and Play features it is very important to carefully plan your BarcoMed Board Hardware and Software inst
56. equi coc lee 25 Software Installatiori cient iere netur cele ences 29 OVeIVIBW cede RESET ER EERU M REED e ETE ER 29 Installing the Windows NT 4 0 Driver for the BarcoMed 2MP2H 2MP2 2MP1NT or 2MP1 Boards 30 Planning Your Barcomed Windows 2000 Installation 33 Installing the Windows 2000 driver for the BarcoMed 2MP2 34 Setting the resolution of your high resolution Monitor 36 System Manual MeDis 2MP2 1NT MGD 221 MKII Installing the Windows 2000 driver for the BarcoMed 2MP1NT 38 Setting the resolution of your high resolution monitor 40 Planning Your Barcomed Windows XP Installation 42 Installing the Windows XP driver for the BarcoMed 2 2 43 Setting the resolution of your high resolution monitor 45 Installing the Windows XP driver for the BarcoMed 2MP1NT 47 Setting the resolution of your high resolution monitor 49 Barco Metheus Configuration Tab sese 51 Introduction iere ret rtr er Ret TET 51 Status ede ebat estie Mv Dee sete du useless 53 Graphics Board 5 eie 53 Driver Version nione tene derer dee dees dede dnce entree e Perd 53 Resolutio 2
57. er Icon Select Manage from the pull down list The Computer Management Dialog box will appear On the left side of the dialog box Select Device Manager from System Tools On the right side of the dialog box click the next to Display adapters to expand the list of adapters For each BarcoMed 2MP2 Imaging Board two display adapters will be listed The display adapters will be listed as Cirrus Logic Laguna 5465 or 2MP2 See Figure 7 on the next page for information on which display adapters should be used when installing the drivers System Manual MeDis 2MP2 1NT MGD 221 MKII 34 BarcoMed software driver installation 2 Lomputer Management t Action view ll Sp 2 EB Eee ALN Computer Head 1 of the 2MP2 ti Disk drives 2 88 Display adapters USE This Head FIRST 2 88 Cirrus Logic Laguna 5465 Cirrus Logic Laguna 5465 ET Computer Management Lacal Ef System Tools Event Viewer System Information E Performance Logs and Alerts 8 49 DVDICD ROM drives a H Floppy disk controllers 3 H E Floppy disk drives Ei Local Users and Groups 29 IDE ATAJATAPI controllers Head 2 of the 2MP2 1 8 Keyboards Disk M t i saris amp Mice and other pointing devices USE This Head second S Locka Orves j B onto H 1 Removable Storage HA Network adapters Services and Applications
58. er s files from drop down menu or browse to the location of your driver and Click Select 2MP1NT in the Select a Device Driver window Click Next When Windows XP has begun installing the BarcoMed 2MP1NT driver it will warn you that the software has not passed Windows System Manual MeDis 2MP2 1NT MGD 221 MKII 47 BarcoMed software driver installation Logo testing to verify its compatibility with Windows XP Click Continue Anyway to install the drivers 11 When the drivers are installed click Finish on the update driver wizard and close the properties page for the device If you are installing multiple BarcoMed 2MP1NT Imaging Boards in your system reboot your system in VGA Mode when asked Repeat steps 3 11 until you have installed all of the adapters Display Properties Themes Desktop Screen Saver Appearance Settings Drag the monitor icons to match the physical arrangement of your monitors Display 1 Default Monitor on Cirrus Logic Laguna 5465 Screen resolution Color quality Less g Mare Low 8 bit 640 by 480 pixels um Use this device as the primary monitor Extend my Windows desktop onto this monitor Figure 13 Windows XP Display Properties Setting Tab before the Barcomed 2MP1NT drivers have been installed Note The system above has two BarcoMed 2MP1NT installed and NO 3 party VGA card The first rectangle
59. es after the vertical sync more than 8 lines resulting in a phase error geometry distortion at the top of the image SH Compensation optional If your display is equipped with the Southern Hemisphere option the on screen display menu contains additional functions to adjust the image geometry If the option is not installed in the display this menu does not appear SH Compensation SH Compensation ON OFF For proper geometry adjustment in the Southern Hemisphere you must switch SH Compensation ON If not the SH controls will not function SH Compensation SH Top System Manual MeDis 2MP2 1NT MGD 221 MKII 100 Display user manual SH Compensation SH Position With SH Compensation on we advise to use the SH Position control instead of the Horizontal Position control in the Geometry menu Advanced geometry Horizontal skewing Advanced geometry Horizontal bowing Advanced geometry Horizontal trapezium Advanced geometry Horizontal parabola Advanced geometry Corner top left System Manual MeDis 2MP2 1NT MGD 221 MKII 101 Display user manual Advanced geometry Corner top right Advanced geometry Linearity amp S correction Horizontal linearity Advanced geometry Linearity amp S correction Horizontal S corr Advanced geometry Vertical linearity
60. etheus Configuration Tab supports the following languages English U S default Dutch German Korean Japanese Simplified Chinese Traditional Chinese To change between the languages select the correct region via the Regional Settings Control Panel in your machine s Start gt Settings gt Control Panel System Manual MeDis 2MP2 1NT MGD 221 MKII 56 BarcoMed software driver installation BARCO METHEUS HARDWARE CONFIGURATION TAB Introduction The BARCO Metheus Hardware Configuration Tab is used for gathering information about BarcoMed imaging boards For all BarcoMed imaging boards it will display PCI information In addition for BarcoMed imaging boards based on the AURA video chipset it will also display information about the Firmware installed on the board BarcoMed Board Types BARCO Metheus Hardware Configuration Tab Support PCI and Firmware Information 3MP2FH PCI and Firmware Information Non AURA Information 5MP1H PCI Information Only 5MP2 PCI Information Only System Manual MeDis 2MP2 1NT MGD 221 MKII 57 BarcoMed software driver installation To access the BARCO Metheus Hardware Configuration Tab do the following 1 Open the Display Properties Control Panel by right clicking on the desktop then select Properties 2 Under Windows NT 4 0 Click on the BARCO Metheus Hardware Configuration Tab see figure 18 below Under Windows XP and Windows 2000 click on the Settings ta
61. exit the OSD and then press the control knob to switch to stand by mode To activate the display from stand by mode press the control knob 4 again As a result the LED is switched off again Automatic power saving system DPMS The power saving system if switched on can power down the display when you don t use the computer that produces the video and sync signals for a while In that way the system reduces the display s power consumption While the display is powered down the picture tube will be blanked and the green LED on the front is blinking In the last DPMS mode the LED will be on continuously The power saving system is switched off when the display is produced It can be switched on by a qualified technician Note The power saving system can only work if the connected imaging board supports power management For more details please read Appendix A Background information System Manual MeDis 2MP2 1NT MGD 221 MKII 91 Display user manual Contrast and brightness control Contrast and brightness can be controlled through the OSD menus To activate the OSD Turn the control knob 4 from left to right or from right to left As a result the OSD main menu appears Note The control knob should turn over at least 30 degrees before the OSD becomes visible MAIN MENU Contrast CAL Brightness CAL Status information Settings Adjustments Exit The OSD main menu The main menu indicates the
62. from Select the rectangle that represents the first head of the BarcoMed 2MP2 Imaging Board you are working with SPECIAL NOTE If the you are using the VGA capabilities of your BarcoMed 2MP2 Imaging Board the resolution for that board will still be set to a VGA resolution of 640 x 480 pixels If the BarcoMed 2MP2 Imaging Board is not running VGA the device may not be enabled yet To enable the device check the Extend my Windows desktop into this monitor checkbox Click the Apply button 4 Click on the Advanced Button 5 Select the Adapter tab and then click on the List All Modes button Select the resolution and refresh rate that your monitor supports from the dialog box and click OK Click OK on the bottom of the Adapter Control Panel If the button on the bottom of the Adapter Control Panel is not visible press the Tab Key once and then press Enter System Manual MeDis 2MP2 1NT MGD 221 MKII 36 BarcoMed software driver installation 6 Click OK in the Windows will now apply your new desktop settings dialog box Your high resolution display s should now synchronize and display the Windows desktop Click Yes when asked Your desktop has been reconfigured Do you want to keep these settings Repeat steps 1 7 for each monitor on all the BarcoMed Imaging Boards installed in your system When you have set the resolution for all of your high resolu
63. g board installed in the selected PCI slot Hardware Version Displays the Hardware Version for the BarcoMed imaging board installed in the selected PCI slot Advanced Button By clicking on this button the user can display more information about the BarcoMed imaging board installed in the selected PCI slot Generate Report Button Clicking this button will produce two reports It will first run the Windows Diagnostics program which will generate a report that is saved to a text file For Windows XP and Windows 2000 this file will be saved on the c drive and it will be named BarcoMetheusReport txt For Windows NT 4 0 this file will be saved on the desktop and it will have the same name as the machine for which the report is being generated The other report that is generated contains information about the Barco display adapters installed in the system and will be named BarcoMedDevicelnfo txt This report will be saved on the desktop These files can be emailed to our customer support department when reporting a problem To locate the closest BarcoView Support office see the Support section on www barcomedical com If your system is connected to the internet and a web browser is installed you can click on the link at the top of the BARCO Metheus Hardware Configuration Tab to get to our web site System Manual MeDis 2MP2 1NT MGD 221 MKII 60 BarcoMed software driver installation Update Device Button Clicking this butt
64. heus DPMS Screen Saver are included in the chapter on the Barco Metheus DPMS Screen Saver System Manual MeDis 2MP2 1NT MGD 221 MKII 29 BarcoMed software driver installation Installing the Windows NT 4 0 Driver for the BarcoMed 2MP2H 2MP2 2MP1NT or 2MP1 Boards SPECIAL NOTE Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board s connect the monitor s to the card s and turn the monitor s on Refer to the Hardware Installation Guide that came with your BarcoMed Imaging Board s for instructions on installing the BarcoMed Imaging Board s and connecting them to the monitor s To install the BarcoMed 2MP2H 2MP2 2MP1NT or 2MP1 Windows NT Display Driver log on using an account with administrator privileges Insert the BarcoMed Driver Media into your machine s appropriate drive and follow these steps 1 Open the Display Properties Control Panel by right clicking on the desktop then select Properties Click on the Settings Tab Select Display Type Select Change Select Have Disk Select the correct drive from the drive menu and click on OK Select the appropriate BarcoMed product and click on OK You will see a message saying that this is a Third Party Driver and asking if you wish to proceed Click on Yes 0 wn 9 The driver files will be copied onto your system 10 You will receive a message saying the driver is successfully
65. ion Boot the machine and log on using an account with administrative privileges Windows XP will automatically load the drivers for the Cirrus Logic Laguna 5465 the chipset used on the BarcoMed 2MP1NT imaging board To install the BarcoMed 2MP1NT drivers right click on the desktop and select Properties Select the Settings tab see Figure 13 on the next page For each BarcoMed 2MP1NT imaging board installed there will two rectangles representing the two display adapters installed on each Barco 2MP1NT However only one display adapter is enabled Double click on the rectangle that represents the first display adapter of the BarcoMed 2MP1NT Imaging Board you are working with to open its properties page Select the Adapter tab and click the Properties button The 2MP1NT Properties page will open Select the Driver tab and click the Update Driver button The Hardware Update Wizard will start Select the Radio Button beside Install from a list or specified location Advanced Click Next On the Please choose your search and installation options page of the Hardware Update Wizard select the Radio Button beside Don t search will choose the driver to install Click Next In the Select a Device Driver page of the wizard click Have Disk Insert your driver disk and select the correct device from the Copy manufactur
66. le Amount of Time in each DPMS State After the workday the monitor will be placed into one of the following DPMS Power States Stand By Suspend or Off The default setting is for the monitor to directly go into the Off State and spend no time in the Stand By or Suspend states If the user wishes to go into the Stand By or Suspend states before going into the Off state select the required amount of time for each state If requested the monitor will first go into Stand By state then into Suspend state and then into Off state The properties of DPMS states are listed in the following table System Manual MeDis 2MP2 1NT MGD 221 MKII 65 BarcoMed software driver installation Monitor DPMS State Power Savings Recovery Time Monitor Settings Select the amount of time the monitor requires to warm up Since all CRT based monitors require some warm up time before they are at full performance this ensures that the monitor is ready for use at the beginning of the workday If you have a Barco Medical Monitor select Barco Quick Start If a non Barco monitor is being used select the amount of time it takes your monitor to warm up via the Monitor Setting section Contact your monitor vendor for this warm up time On Barco CORONIS displays the I GUARD will stabilize the image within few seconds after the monitor returns to the active state so there is no need for a warm up time period Use As Logon Screen Saver Check
67. lick Next 16 Windows will warn you that a digital signature was not found Click Yes to continue the installation 17 When the drivers are installed click Finish on the update driver wizard and close the properties page for the device If you are installing multiple BarcoMed 2MP1NT Imaging Boards in your system reboot your system in VGA Mode when asked Repeat steps 11 17 until you have installed all of the adapters Setting the resolution of your high resolution monitor 1 Reboot in VGA Mode and login using an account with administrative privileges If you do not reboot in VGA Mode Windows 2000 may select a resolution that is not compatible with your high resolution monitor and you will then need to reboot in VGA Mode To set the resolution for you monitor open the Display Properties Control Panel by right clicking on the desktop then select Properties Select the Settings tab see Figure 10 on the next page If you are using a single BarcoMed 2MP1NT and no 3 party VGA card there will be only a single desktop to select from If you are using multiple 2MP1NT s select the rectangle that represents the BarcoMed 2MP1NT Imaging Board you are working with SPECIAL NOTE If the you are using the VGA capabilities of your BarcoMed 2MP1NT Imaging Board the resolution for that board will still be set to a VGA resolution of 640 x 480 pixels If the BarcoMed 2MP1NT Imaging Board
68. llow these steps 1 Install the BarcoMed 2MP1NT adapter s into the machine Refer to the hardware installation manual for more information 2 Boot the machine and press F8 when the system displays Starting Windows 3 Select Enable VGA Mode If you do not boot in VGA mode the system will boot normally and load the default Windows 2000 VGA Compatible Driver This driver is not compatible with most high resolution monitors and you may not be able to see any video output on the monitor At this point you can either 8 reboot in VGA mode if you are using the 2MP1NT as your VGA card or b connect a VGA capable monitor and continue with the rest of the instructions 4 Log on using an account with administrative privileges 5 Right click on the My Computer Icon 6 Select Manage from the pull down list The Computer Management Dialog box will appear 7 On the left side of the dialog box Select Device Manager from System Tools 8 On the right side of the dialog box click the next to Display adapters to expand the list of adapters 9 For each BarcoMed 2MP1NT Imaging Board two display adapters will be listed The display adapters will be listed as Cirrus Logic Laguna 5465 or BarcoMed 2MP1NT However only display adapter is enabled on the Imaging Board itself See Figure 9 on the next page for information on which display adapters should be used when installing
69. ly ONE of the BarcoMed 2MP2 and or BarcoMed 2MP1NT Imaging Board s and disable VGA on ALL other BarcoMed Imaging Board s Standard Jumper Functions JP100 Primary VGA enable Off Pins Open for primary display only Factory testing only Do NOT Change Figure 2 2MP2 and 2MP1NT Jumper Settings Table System Manual MeDis 2MP2 1NT MGD 221 MKII 18 Imaging board installation Installing the BarcoMed 2MP2 or 2MP1NT Graphics Controller To install the BarcoMed 2MP2 or BarcoMed 2MP1NT into your computer follow these steps 1 Turn off the power to your computer and disconnect the power cord 2 Remove the chassis cover according to the manufacturer s instructions Be sure to observe safety warnings 3 If you have decided to use the on board VGA capabilities of the BarcoMed 2MP2 or BarcoMed 2MP1NT see Using the VGA capabilities of the BarcoMed 2MP2 or BarcoMed 2MP1NT you must now remove any VGA cards that are currently installed in the computer You may also need to uninstall the drivers for that VGA board Consult the User Guide for your VGA board for instructions on removing the driver If your system has an integrated VGA card you may need to make changes to your system s BIOS settings in order to use the VGA capabilities of your BarcoMed board Consult your system manual s for instructions on making changes to the BIOS settings SPECIAL NOTE If you have a separate VGA card and it has a Cirru
70. m Manual MeDis 2MP2 1NT MGD 221 MKII 106 Display user manual TROUBLESHOOTING There appears no image on the picture tube the green LED at the rear is out Check if the power cord is properly connected to the power outlet and to the display Check if the power button is switched on There appears no image the green LED is on The display is switched in Stand by manually or by the automatic Power saving system Press the control knob at the rear shortly Try to switch on the display by pressing any key on the keyboard of the computer that produces the video and sync signals for the display Check if both horizontal and vertical sync signals are connected to the display and to the computer There appears no image the green LED is blinking The display is switched in a power saving mode by the automatic Power saving system Press the control knob at the rear shortly Try to switch on the display by pressing any key on the keyboard of the computer that produces the video and sync signals for the display Check if both horizontal and vertical sync signals are connected to the display and to the computer On the picture tube appears the message No Valid Sync Signal Check if both horizontal and vertical sync signals are connected to the display and to the computer e Check if the sync signals are connected in the proper way refer to the chapter Installation Check if both horizontal
71. mend setting the work day to be as short as possible to get the maximum power savings on CORONIS displays The Barco Metheus DPMS Screen Saver can also be used when no one is logged on System Manual MeDis 2MP2 1NT MGD 221 MKII 63 BarcoMed software driver installation BarcoMetheus DPMS Screen Saver Options From the Barco Metheus DPMS Screen Saver Control Panel you can change many DPMS screen saver elements simultaneously The DPMS screen saver elements in each scheme are work schedule work day screen saver DPMS settings after workday and many additional options Current Scheme Lists the three DEFAULT schemes which you can use as they are Or you can modify them to meet your office s schedule Save As Saves your current Barco Metheus DPMS Screen Saver settings The name you specify will appear in the Scheme list so you can easily restore these settings later Delete Deletes the scheme that is selected in the Scheme box Work Schedule Select the begin and end times for each workday If the system is not expected to be used leave both start and end workday times as the same time Begin Work Day The Begin Work Day time is the time after which the system is expected to start being used During the workday the screen saver selected by the user in the Screen Saver During Work Day section is used during user inactivity End Work Day The End Work Day time is the time after which the system is not exp
72. mm x 630mm x 780mm Dimensions monitor mm Height 558 Width 400 Depth 561 Modifications reserved System Manual MeDis 2MP2 1NT MGD 221 MKII 110
73. n menu Then click on Details Check if the Powersave option is checked If not check it This is necessary to use the DPMS possibilities of the imaging board 5 For all the displays in the system define if necessary and select a Preset 6 After selecting the Preset MediCal starts consistency calibration automatically 7 Define the Q A task schedule 8 Run the due tasks Please refer to the MediCal User Guide for more information System Manual MeDis 2MP2 1NT MGD 221 MKII 77 MediCal software installation and usage This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 78 DISPLAY USER MANUAL Display user manual This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 80 Display user manual 2001 BARCO nv All rights reserved Trademark information TrueGrey MediCal BarcoMed and MeDis are registered trademarks of BARCO NV Windows NT is a registered trademark of Microsoft Corporation System Manual MeDis 2MP2 1NT MGD 221 MKII 81 SAFETY INSTRUCTIONS RISK OF ELECTRIC SHOCK 2 DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER TO QUALIFIED SERVICE PERSONNEL Regulations e This apparatus conforms to IEC601 1 UL2601 1 cUL2601 1 EN 60601 1 This apparatus is classified as Type B without Applied Part Usage
74. nnector on the display The sensor is not supplied with the display Calibration and adjustments The conformity calibration as well as the complete adjustment of the display can be performed by means of the remote user friendly MediCal software package MediCal is especially developed to adjust and check BARCO s medical displays System Manual MeDis 2MP2 1NT MGD 221 MKII 83 Display user manual A lot of adjustments can also be done on the monitor itself by means of an extensive on screen menu system accessible from the rear panel controls Power saving system The MGD 221 is equipped with a power saving system When left idle for a certain time the computer connected to the display will power down the display in several steps The power saving system can be switched on or off during the installation or adjustment of the display This system requires a computer imaging board that supports power saving management Versions and options The MGD 221 comes in 2 different versions With an anti reflective panel in front of the picture tube and without panel No Panel version In both cases the phosphor is a B4 L8 type The type of CRT phosphor and the presence of the coating are indicated on the label at the rear of the display The video input is terminated to 75 Ohm Important It is absolutely necessary that the impedances of imaging board and display are the same If not the image quality will be inferior The
75. nstant as possible Cover windows to keep out the daylight Avoid switching the lights and viewing boxes on and off A consistent environment results in more image consistency and less eye fatigue Avoid reflections in the picture tube Provide indirect lighting Don t place the displays in front of or close to a light source like a window or viewing box although this may be very tempting As a rule of thumb keep viewing boxes at least one metre 3 feet away from the displays System Manual MeDis 2MP2 1NT MGD 221 MKII 90 Display user manual OPERATION USER CONTROLS Important The best way to adjust and control the display is by using MediCal which displays the ideal test patterns for correct adjustment However in case you do not dispose of MediCal you can control and adjust the display by means of the built in On Screen Display OSD Switching on off Power on off Press the Power button 11 on the rear panel to switch on the display The green LED at the front is off when the display is operating If the display starts up with no image and the green LED 3 on it is in stand by This is the case when the display was powered down while in stand by Manual stand by To put the display in manual stand by mode press the control knob 4 shortly As a result the green LED is ON continuously Note You cannot switch the display in manual stand by when the on screen display OSD is visible In that case first
76. nu Alternatively you can just wait a few seconds and the OSD returns to the previous menu automatically Viewing Status information You can view the status and actual settings of the display You cannot change them in the Status Menu Changing the settings is reserved for trained service staff only To view the status information Turn the control knob to select Status information in the OSD main menu The Status information menu appears The only control in the menu is Exit Explanation of the Status information menu items Display Name STATUS INFORMATION Display Name MGD 221MKII Serial Number 5114147 Mode Name New mode Mode H frequency Mode V frequency Software Version Run time White level Activity timeout SH compensation Actual H frequency 72 02 kHz Actual V frequency 75 00 Hz Exit Status information menu This is the display type Serial Number This is the display s serial number Mode Name The currently selected scanning mode Mode H frequency Mode V frequency These are the horizontal and vertical sync frequencies of the currently selected scanning mode These are the figures stored in the memory System Manual MeDis 2MP2 1NT MGD 221 MkIl 94 Display user manual Software Version The internal software version Run time The total operating time since production including burn in time White level The display s white level or light output after calibration in calibr
77. o signals you want to connect It must be 75 Ohm just like the input of the display If not the quality of the images on the display will be inferior 2 Connect the video output of the computer s imaging board to the video and sync inputs on the display s rear panel Use a proper video cable The video cable is not supplied with the display unless the display comes as part of a complete BARCO MeDis system that also contains an imaging board The inputs accept the following signals Video with separate horizontal and vertical sync The video cable has 3 wires Connect the video signal to the connector Video 7 Connect the horizontal sync signal to the connector HS CS 8 Connect the vertical sync signal to the connector VS 9 Video with external composite sync The video cable has 2 wires Connect the video signal to the connector Video 7 Connect the composite sync signal to the connector HS CS 8 Video with internal composite sync sync on video The video cable has 1 wire Connect the video with sync signal to the connector Video 7 Notes The video inputs cannot be connected in loop through daisy chain The required video amplitude 700 mV x 3 dB The required sync amplitude 500 mV System Manual MeDis 2MP2 1NT MGD 221 MKII 87 Display user manual b Connection of data signals The display can be controlled remotely by a computer through the serial data
78. on will run the BarcoMed Hardware Configuration Wizard This program allows the user to flash update the firmware stored in the ROM of the currently selected BarcoMed imaging board The BarcoMed Hardware Configuration Wizard is a wizard style application that uses dialog boxes to guide the user through the flash update procedure The user will be prompted to select a firmware update file to use for the update therefore you will need a firmware update file for your specific BarcoMed imaging board in order to update it s firmware This file will be provided by BarcoView if and when a firmware update is required Special Note The BarcoMed Hardware Configuration Wizard is applicable only for AURA based imaging boards System Manual MeDis 2MP2 1NT MGD 221 MKII 61 BarcoMed software driver installation This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 62 BarcoMed software driver installation BARCO METHEUS DPMS OVERVIEW Introduction The Barco Metheus DPMS Display Power Management Signaling Screen Saver allows the user to set power and monitor saving features for medical monitors driven by BarcoMed Imaging Boards At the end of the workday the monitor will enter certain DPMS states as requested by the imaging board This is accomplished through standardized signals between the monitor and imaging board The default DPMS state is the Off state In addition to simply entering the Off state after
79. ortant to install the driver for this board and set its resolution first System Manual MeDis 2MP2 1NT MGD 221 MKII 33 BarcoMed software driver installation Installing the Windows 2000 driver for the BarcoMed 2MP2 SPECIAL N OTE Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board s connect the monitor s to the card s and turn the monitor s on Refer to the Hardware Installation Guide that came with your BarcoMed Imaging Board s for instructions on installing the BarcoMed Imaging Board s and connecting them to the monitor s To install the BarcoMed 2MP2 Windows 2000 Display Driver follow these steps 1 2 3 4 5 6 7 8 9 Install the BarcoMed 2MP2 adapter s into the machine Refer to the hardware installation manual for more information Boot the machine and press F8 when the system displays Starting Windows Select Enable VGA Mode If you do not boot in VGA mode the system will boot normally and load the default Windows 2000 VGA Compatible Driver This driver is not compatible with most high resolution monitors and you may not be able to see any video output on the monitor At this point you can either a reboot in VGA mode if you are using the 2MP2 as your VGA card or b connect a VGA capable monitor and continue with the rest of the instructions Log on using an account with administrative privileges Right click on the My Comput
80. ortly to enter the selected category 6 In the selected menu select the adjustment you want to make and press the control knob shortly to display the adjustment scroll bar 7 Turn the control knob to perform the adjustment After adjusting press the knob shortly to confirm the adjustment and return to the menu or press for a longer time to undo the adjustment and return to the menu 8 Return to the previous menu by pressing the control knob shortly or selecting Exit when present b Description of the adjustments Geometry ADJUSTMENTS Geometry Focus ALC Luminance uniformity Factory reset Exit Adjustments menu Rotation System Manual MeDis 2MP2 1NT MGD 221 MkIl 98 Display user manual Width Horizontal position Blanking Blanking top System Manual MeDis 2MP2 1NT MGD 221 MKII 99 Display user manual Interlacing Pre correction In most cases you do not need to change this adjustment You may need to increase this adjustment only when the connected video and sync signal contains an abnormally big number of equalization pulses before the vertical sync more than 8 lines resulting in a phase error geometry distortion at the bottom of the image Interlacing Post correction In most cases you do not need to change this adjustment You may need to increase this adjustment only when the connected video and sync signal contains an abnormally big number of equalization puls
81. our monitors 12 Display 1 Default Monitor on BarcoMed 2 1 Se Coos 3 Screen area 3 s6cos x Less More 256 Colors 2 oae teeth n 3 1200 by 1600 pixels Use this device as the primary monitor Extendimy Windows desktop onto this monitor Identify Troubleshoot Advanced Cancel Apply Figure 10 Windows 2000 Display Properties Settings Tab for the 2MP1NT after the divers have been installed and the resolution set Note The system shown had one BarcoMed 2MP1NT imaging board installed with VGA enabled Your configuration may be different System Manual MeDis 2MP2 1NT MGD 221 MKII 41 BarcoMed software driver installation Planning Your Barcomed Windows XP Installation Because of Windows XP s Plug and Play features it is very important to carefully plan your BarcoMed Board Hardware and Software installation and install the device drivers in the same sequence that the boards are installed in the PCI slots When installing BarcoMed Imaging Boards for the first time in a Windows XP System Windows XP Plug and Play Software identifies the BarcoMed boards by the Video Chipset utilized on each boards The Table below shows the BarcoMed Board the Chip Set utilized by the board and the driver Windows XP Plug and Play selects for each imaging board Driver Selected by BarcoMed Windows 2000 Board Model Chip Set
82. re tete aede 95 Advanced settings and Adjustments For service staff only 96 Settings s Bear tede pe ns ERR HR MU HER US 96 Adjustments aene etos o Rer os t e bo iis 98 a How to make the adjustments sss 98 b Description of the adjustments 98 Geometry nineteenth iier 98 FOCUS 104 ALC optional 5 0 deen rio ei e ein 104 Luminance uniformity cee nee 105 Factory reset eu eee fre rrr er e a DEP ERR 105 c How to save changes 105 System Manual MeDis 2MP2 1NT MGD 221 MKII Maintenance 106 Picture 106 CAbDING E 106 Troubleshooting 2 tee derit tette dne Ie Ene re 107 Appendix A Background information ses 108 Luminance Uniformity Correction sss 108 Power SAVING System ce cte cete roe tre Leine eade 108 Appendix B Technical specifications 110 System Manual MeDis 2MP2 1NT MGD 221 MKII INTRODUCTION System Manual MeDis 2MP2 1NT MGD 221 MKII Introduction This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 8 Introduction INTRODUCTION BARCO is a total
83. resenting the two heads supported by each Barco 2MP2 to select from Select the rectangle that represents the first head of the BarcoMed 2MP2 Imaging Board you are working with SPECIAL NOTE If you are using the VGA capabilities of your BarcoMed 2MP2 Imaging Board the resolution for that board will still be set to a VGA resolution of 640 x 480 pixels If the BarcoMed 2MP2 Imaging Board is not running VGA the device may not be enabled yet To enable the device check the Extend my Windows desktop into this monitor checkbox Click the Apply button Click on the Advanced Button Select the Adapter tab and then click on the List AII Modes button Select the resolution and refresh rate that your monitor supports from the dialog box and click OK Click OK on the bottom of the Adapter Control Panel If the OK button on the bottom of the Adapter Control Panel is not visible press the Tab Key once and then press Enter Click OK in the Windows will now apply your new desktop settings dialog box Your high resolution display s should now synchronize and display the Windows desktop Click Yes when asked Your desktop has been reconfigured Do you want to keep these settings Repeat steps 1 6 for each monitor on all the BarcoMed Imaging Boards installed in your system When you have set the resolution for all of your high resolution monitors restart your computer and boot normally
84. ring menu until the Save Changes message appears 2 Select Yes to save the changes Select No to exit the OSD menus without saving the changes What happens upon saving When the current scanning mode was already stored in the display memory the scanning mode is updated with the new adjustment values When the scanning mode was not yet stored in the memory the display will create a new scanning mode in the memory However when the memory was full the monitor will display a list of scanning modes in the memory and ask if you wish to overwrite one of them If you want to store the adjustments you have made you will have to overwrite one of the scanning modes in memory System Manual MeDis 2MP2 1NT MGD 221 MKII 105 Display user manual MAINTENANCE Picture tube The glass panel of the picture tube is handled with a special coating Take care not to damage or scratch the coating Clean the picture tube with a soft woolen or cotton cloth The cloth should be moist not wet Use a watery solution or a mild commercial glass cleaning solution Apply e g spray the solution on the cloth not on the picture tube Cabinet Clean the cabinet using a recognized cleaning product for medical equipment The cloth you use must be moist not wet The cabinet has been tested for resistance to the following products Cidex Betadine Alcohol Isopropyl and Ethyl Ammonia based cleaners Windex and Aquasonic Gel Syste
85. s chip you must remove it from your system before installing the BarcoMed 2MP2 or BarcoMed 2MP1NT If you have on board VGA that uses a Cirrus chip consult your system manual on how to disable it before installing the BarcoMed board s Once the system VGA is disabled you must ensure that the BarcoMed board s VGA capabilities are enabled if you want to see your boot messages 4 Install the BarcoMed 2MP2 or BarcoMed 2MP1NT Graphics Controller into a free PCI slot Be sure that the board is seated firmly in the slot 5 Secure the card to the chassis with the PC s I O panel mounting screw and replace the chassis cover 6 Connect the left hand display to the uppermost connector on the BarcoMed 2MP2 or BarcoMed 2MP1NT VID 1 see figure on next page using the provided video cable For a dual headed BarcoMed 2MP2 setup connect the right hand display to the other connector VID 2 on the board 7 Each of the display cables has three BNC connectors on it The green one is the video the black one is the horizontal sync and the white one is the vertical sync 8 Install the power cord turn on the power and boot the system as usual System Manual MeDis 2MP2 1NT MGD 221 MKII 19 Imaging board installation Running Multiple BarcoMed 2MP Boards in a Single Host NOTE The physical order of the displays may vary when you are running multiple BarcoMed 2MP boards This is due to the PC s PCI bus control in the system BIOS and not the Bar
86. s only available when the User Modifiable Palette Mode is selected This is because dithering is only supported under Windows when the display is palletized If either the Static Gray Palette including Standard System Colors mode or the Static Gray Palette with NO System colors mode is selected the Enable Dithering check box will be grayed out and dithering will be automatically disabled regardless of whether this check box is checked This complies with the Windows standard interface method Monitor Configuration This option allows you to select the number of monitors that the current display boards should drive as well as how the monitors should be positioned For example if the current board installation is capable of driving four heads but you only have three monitors which are placed in a single row then you can select the Three monitors System Manual MeDis 2MP2 1NT MGD 221 MKII 55 BarcoMed software driver installation one row option from the pull down list This would cause the Windows virtual desktop to be resized to fit on the three monitors and you can move your cursor horizontally from one screen to the other If Custom Configuration is displayed it means that the current monitor configuration was set via the registry and it doesn t agree with any of the configurations that the display control panel supports Contact Barco Medical Imaging Systems for further information Languages supported The Barco M
87. s system manual is a copy of the display user manual Follow the precautions and guidelines from this part The display s from a multihead MeDis system are numbered E g in a quad head system the displays are numbered 1 to 4 You can find the number of the display on a label at the rear side In a multi head system the order in which you place the displays is not random From left to right or from top to bottom in ascending order The displays remote addresses are properly set at the factory The addresses correspond to the display numbers on the rear label Display 1 has address 1 etc Note Should anything be wrong with the display addresses this can easily be solved by running the Configuration Setup Wizard in MediCal Pro For more information please refer to the MediCal part of this manual Connection of the video cables MeDis 2MP1NT Plug in the D15 connector of the video cable into the connector of the imaging board as described in the BarcoMed installation guidelines inside this manual Plug in the large coaxial connectors BNC of the video cable into the connectors of the display The video cable connector with green plastic plugs into the display connector marked Video The connector with black plastic plugs into the display connector marked HS CS The connector with white plastic plugs into the display connector marked VS System Manual MeDis 2MP2 1NT MGD 221 MKII 24 Display installation Me
88. static charges can damage the board Familiarizing Yourself With the BarcoMed 2MP2 or BarcoMed 2MP1NT Imaging Board Prior to installing your 2MP2 or 2MP1NT board s in your PC please take a few minutes to familiarize yourself with both the board and the PCI slots in your computer JP104 JP100 JP102 JP107 UUs JP1 Figure 1 The BarcoMed 2MP2 and BarcoMed 2MP1NT Jumper Location There is one user settable jumper on the BarcoMed 2MP2 and BarcoMed 2 1 It is used to enable or disable the VGA capabilites of the board Using the VGA Capabilities of the BarcoMed 2MP2 or BarcoMed 2MP1NT Prior to installing the BarcoMed 2MP2 or BarcoMed 2MP1NT decide if you are going to use its on board VGA capabilities If you are System Manual MeDis 2MP2 1NT MGD 221 MKII 17 Imaging board installation check the setting of the Jumper at J 100 on the graphics board See Figure 1 on the preceding page By default VGA should be disabled i e on both pins If you decide to use your multisyncing high resolution grayscale monitor as your boot monitor you must enable the on board VGA capabilities of the BarcoMed 2MP2 or 2MP1NT Imaging Board by removing the jumper from the pins at J 100 We suggest placing the jumper on only one of the two pins so that you don t lose the jumper NOTE To use multiple BarcoMed 2MP2 and or BarcoMed 2MP1NT Imaging Board s in a single host with VGA enabled you need to enable VGA on on
89. the box to use the Barco Metheus DPMS Screen Saver when no one is logged into the system Uncheck the box to use the default screen saver when no one is logged into the system Installing the BarcoMetheus DPMS Screen Saver To install the DPMS Screen Saver you must have the Microsoft Windows Installer program installed on your system To verify that it is installed use Windows Explorer to search for the following file If you do not find this file you can install it from the BarcoMed Software CD by following the steps below If the Windows Installer is installed on your system skip to step 6 below 1 Insert the BarcoMed Software CD in your system s CD drive System Manual MeDis 2MP2 1NT MGD 221 MKII 66 BarcoMed software driver installation 2 Use Windows Explorer to navigate to the following folder CD drive DPMS_ScreenSaven On Windows NT 4 0 systems install the Windows Installer by double clicking on the file instmsiw exe On Windows 2000 and Windows XP systems install the Windows Installer by double clicking on the file instmsia exe 3 Restart your system if prompted to do so 4 Now install the DPMS Screen Saver by double clicking on the file 5 CD drive ADPMS ScreenSaver setup exe This will launch the Windows Installer which will guide you through the DPMS install process Click Next to continue 6 The Customer Information page will appear The Installer will automatic
90. the drivers System Manual MeDis 2MP2 1NT MGD 221 MKII 38 BarcoMed software driver installation 2 Lomputer Management 51 Action view ll d gt Eg m Computer Head 1 of the 2MP1NT a ET Computer Management Lacal System Tools Event Viewer 1 System Information d Performance Logs and Alerts E Shared Folders H ES DVD CD ROM drives en H 6 Floppy disk controllers ag Se aeger Disabled Head Ei Local Users and Groups Disk Management 73 Disk Defragmenter Logical Drives 1 1 9 Removable Storage Services and Applications H E Disk drives z 5 Display adapters USE This Head Cirrus Logic Laguna 5465 Cirrus Logic Laguna 5465 Floppy disk drives IDE ATAJATAPI controllers d Keyboards 1 amp 3 Mice and other pointing devices Monitors 9 Network adapters He Ports COM amp LPT fr Sound video and game controllers t E System devices Universal Serial Bus controllers DO NOT USE Figure 9 Windows 2000 Display Adapters Window In the example above there was one BarcoMed 2MP1NT installed in the system and NO 3 party VGA card The first Cirrus Logic Laguna 5465 shown is the functional head on the BarcoMed 2MP1NT Use this as the device when installing the BarcoMed 2MP1NT driver The second Cirrus Logic Laguna 5465 shown
91. thin a few seconds after the monitor returns to the active state thus eliminating the need for a warm up period at the beginning of the workday If you wish to use this DPMS screen saver as the screen saver at logon time check the Use As Logon Screen Saver box in the Additional Options section Save your preferences by pressing the Save As button and entering a new profile name in the Save Profile Setting dialog box Apply your new scheme by clicking OK Click OK again to close the Display Properties Control Panel Uninstalling DPMS To remove DPMS screen saver from your system do the following For Windows NT 4 0 Systems 1 2 3 Launch the Windows Control Panel Then double click the Add Remove Programs Icon Highlight DPMS Screen Saver in the Dialog Box Click the Add Remove button The Windows Installer will ask if you are sure you want to remove this program click Yes When the Windows Installer has finished removing the program click OK to exit the Add Remove Program Properties dialog box Close the Control Panel window System Manual MeDis 2MP2 1NT MGD 221 MKII 73 BarcoMed software driver installation For Windows 2000 and Windows XP Systems 1 2 3 Launch the Windows Control Panel Then double click the on Add Remove Programs Highlight DPMS Screen Saver in the Currently Installed Programs window Click the Change Remove button
92. tilize a UL listed detachable power cord 3 wire type SJ or equivalent 18 AWG min rated 300 V min provided with a hospital grade type plug 5 15P configuration for 120V application or 6 15P for 240V application 2 Plug one end of the power cord into the rear of the display connector LINE 10 Plug the other end into a grounded AC power outlet The display automatically adapts to the voltage The voltage range is 100 240 VAC 10 Positioning the display The tilt and swivel base allows you to adjust the height and viewing angle of the display to obtain an optimal viewing comfort System Manual MeDis 2MP2 1NT MGD 221 MKII 89 Display user manual Important considerations The best environment for diagnostic imaging is one with controlled and dimmed ambient light The human eye s sensitivity depends on the ambient light strength It is most sensitive to small contrast changes or subtle image details at limited ambient light levels The best ambient light level expressed in Lux depends on the application An office illumination typically requires 500 Lux A dimmed environment like a softcopy room requires less than 100 Lux Using your display in a controlled and dimmed environment also extends its lifetime because the display can operate at limited brightness and contrast These levels correspond to the calibrated position in most cases A controlled ambient light environment implies the ambient light is as co
93. tion monitors restart your computer and boot normally N Display Properties 2 xj Background Screen Saver Appearance Web Effects Settings Drag the monitor icons to match the physical arrangement of your monitors 1 2 Display 1 Default Monitor on BarcoMed 2MP2 m Colors Screen area 256 Colors e 1200 by 1500 pixels Use this device as the primary monitor Extendimy Windows desktop onto this monitor Identify Troubleshoot Advanced Cancel Apply Figure 8 Windows 2000 Display Properties Window for the 2 2 after the drivers have been installed and the resolution set Note The system shown above had one 2MP2 installed and no 3 party VGA Card Your configuration may be different The monitor marked 1 is the first head of the 2MP2 and the monitor marked 2 is the second head of the 2MP2 System Manual MeDis 2MP2 1NT MGD 221 MkIl 37 BarcoMed software driver installation Installing the Windows 2000 driver for the BarcoMed 2MP1NT SPECIAL NOTE Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board s connect the monitor s to the card s and turn the monitor s on Refer to the Hardware Installation Guide that came with your BarcoMed Imaging Board s for instructions on installing the BarcoMed Imaging Board s and connecting them to the monitor s To install the BarcoMed 2MP1NT Windows 2000 Display Driver fo
94. tte Static Gray Palette including standard system colors Static Gray Palette with NO system colors m Drawing Modes Iv Enable Direct Draw Iv Enable Dithering Monitor Configuration Two monitors single row E Figure 16 Configuration Tab under Windows 2000 Default Monitor and BarcoMed 2MP2H Properties 3 3 X9 Barco Metheus Hardware Configuration General Adapter Monitor Troubleshoot Color Management BARCO Metheus Configuration Bance http www barcomedical com Status Graphics Board BarcoMed 2MP2H Driver Version 5 1 00 Resolution 1200 1600 75 Hz Palette Mode User Modifiable Color Palette Static Gray Palette including standard system colors Static Gray Palette with NO system colors Drawing Modes Enable Direct Draw Enable Dithering Monitor Configuration DualView is active z Figure 17 Configuration Tab under Windows XP System Manual MeDis 2MP2 1NT MGD 221 MKII 52 BarcoMed software driver installation Status Displays the current BarcoMed Imaging Board driver and the currently selected display resolution Graphics Board This displays the current BarcoMed Imaging Board Driver Version This displays the current BarcoMed driver version Resolution This displays the currently selected display resolution Palette Mode You can choose one of the following Palette Modes UserModifiable Color Pale
95. tte This option allows applications to modify the palette contents dynamically As indicated by the picture below this mode reserves the first 10 and last 10 entries in the palette for the Windows operating system but applications can manipulate the middle 236 entries This is the standard palette mode as configured by Windows 0 9 46 255 system colors remaining palette values palette entry 6 has RGB value of 0 128 128 Static Gray Palette including standard system colors This option sets the palette to be a static set of 256 gray values Therefore applications are denied the ability to dynamically change or allocate palette entries This prevents palette conflicts between applications which can cause image color values to appear distorted in the background application As shown in the next picture the 20 standard system colors are converted from RGB to gray values The rest of the 236 entries from System Manual MeDis 2MP2 1NT MGD 221 MKII 53 BarcoMed software driver installation index 10 to 245 contain the missing gray values so that the palette has the full 256 gray values within it 0 9 255 remaining 236 gray values JE colors system colors palette entry 6 has RGB value of 89 89 89 Please note that dithering is not permitted while in this mode The Enable Dithering check box will be grayed out and dithering will be automatically disabled regardless of whether this check box is checked
96. ug the other end the D9 male connector into the Remote In connector on one of the displays In case of a multi head system take a second Remote cable Plug the D9 female connector into the Remote Out connector of the display you have connected in step 2 Plug the other end of the cable into the Remote In connector of another display Proceed in this way until all displays are daisy chained through the Remote bus Power up the system Connect the displays and PC to the power supply Switch on all the devices System Manual MeDis 2MP2 1NT MGD 221 MKII 25 Display installation This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 26 BARCOMED SOFTWARE DRIVER INSTALLATION BarcoMed software driver installation This page intentionally left blank System Manual MeDis 2MP2 1NT MGD 221 MKII 28 BarcoMed software driver installation SOFTWARE INSTALLATION Overview The BarcoMed 2MP Family Software Installation section has been divided into three sections one for each of the three supported versions of the Windows operating system They are Windows NT 4 0 Windows 2000 and Windows XP Because of Windows 2000 s and Windows XP s Plug and Play features and their ability to support multiple types of imaging boards simultaneously those sections have been further subdivided by the various BarcoMed imaging board models Since Windows NT 4 0 supports only one type of imaging
97. witched on or off by a qualified technician Power saving system The display is equipped with circuits that can handle power saving management When the system is switched on it can power down the display in several steps The system is controlled by the imaging board or the PC that delivers the video signals When you are working on the computer the imaging board delivers both sync signals and the display is operating normally When you don t touch the computer keyboard for a certain time the imaging board only delivers vertical sync This is sensed by the display s micro controller that blanks the image on the CRT This results in a drop of power consumption with about 25 96 System Manual MeDis 2MP2 1NT MGD 221 MKII 108 Display user manual When you leave the computer idle for a longer period the imaging board now delivers horizontal sync only As a result the display s micro controller switches off a number of internal circuits The power consumption has now dropped with about 42 96 At last the imaging board delivers no sync signals at all and the micro controller switches off all but one power supplies in the display Only the micro controller s own supply keeps on running resulting in a very low power consumption of 6 W If you start using the computer again the imaging board switches on both sync signals and the micro controller switches on the display The times after which the different steps of power management
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 Windows XP編 SBS TEFLIPUN40Y mobile phone case Bedienungsanleitung Triarch 29773 User's Manual MC01 04 MC01 04 HT-CT500 1.14MB Copyright © All rights reserved.
Failed to retrieve file