1. Model PTS 2000 Load cell Capacity 2000 kg Resolution 0 5 kg Fork length 1150mm Fork Width each 160mm Fork Width total 550mm Fork Height 80mm increasing to 195mm Net Weight 110k See the User Manual for the Indicator supplied with the PTS for more information about the weighing features and operation 1 2 PACKING LIST Part No Part name QTY 3101410695 Indicator mounting bracket upper 301177255 M4 x 6 SS Soc Head cap Screw din912 A2 3106610715 PTS Manual Instructions 3101010700 M4 Allen key 3101710929 Roller pin 620X110 3101710930 Spring Pin 5X35 3101210931 Handle 2100010935 AE402 indicator assembly hihlbinininin pin 3104010713 AE402 load cell cable 5 Adam Equipment 2010 FIG 3 Adam Equipment 2010 O 1 2 3 4 2 0 INSTALLATION Please follow the installation instructions to ensure correct operation of your PTS In transportation the handle is removed from the truck this needs to be installed following the instructions below NOTE Do not lower the handle down fully until completing the instructions below Insert the roller pin into the hole of roller rack securing the handle to the frame Fit the split pin through the holes provided Pass the chain through the center hole of the roller pin Secure the end of the chain to the slot on the end of the unloading plate R
2. Counting Scales for Industrial and Warehouse applications Digital Weighing Check weighing Scales High performance Platform Scales with extensive software features including parts counting percent weighing etc Crane scales for heavy duty industrial weighing Digital Electronic Scales for Medical use Retail Scales for Price computing O Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website Visit us at www adamequipment com Adam Equipment 2010 O
3. move the handle up and down several times to allow air to escape e Routine maintenance is necessary You should focus on the wheels and handle assemblies When the truck is not in use remove the items on the forks and reset the forks to their lowest position e All the bearings and axles have been lubricated please check at regular intervals 14 Adam Equipment 2010 O C Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Eguipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect ca
4. EHEADAM Adam Equipment PTS SERIES With AE402 Indicator P N 3106610715 Revision C October 2010 Adam Equipment 2010 O Adam Equipment 2010 O Thank you for purchasing the ADAM PTS 2000 For your safety and correct operation please read the following instructions carefully before using it CONTENT 1 0 INSTRUCTION az nine A as EA eat ne date nent dada 5 1 1 SPECIFICATION seen ii nade Road onl hag ae meta sta mate 5 1 2 PACKING IST viii nd rene a da da ad da genie 5 2 0 INSTALLATION o A TA 7 21 AE 402ASSEMIBIYS citant iniciado a a aa ae a e 8 3 0 CALIBRATION cua a a a a 12 4 0 TROUBLE SHOOTING st steesedessgectvenccatbecds id in EAR EAE E 13 5 0 MAINTENANCE tacie a A Ri 14 3 Adam Equipment 2010 O SAFETY e To prevent damage to the scale please read these operating instructions thoroughly e When using the pallet truck please keep the handle in the DRIVE position e This pallet truck must be operated by trained personnel only Fig 1 e Check the pallet truck first before using it making sure that the wheels handles and forks are fitted correctly and secure e Avoid unsuitable and uneven floor surfaces e Please wear protective clothing where necessary e Allow 60cm clearance from the pallet truck when operating e Pay attention and focus on the object you are lifting e Do not overload FIG 2 4 Adam Equipment 2010 1 0 INSTRUCTION 1 1 SPECIFICATION Common specifications
5. bles must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment WEEE COMPLIANCE ees a Qu Sealed Lead Acid NZ L Y Battery i Must be recycled mid E w Properly Es PB Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 B are set to impose targets for Adam Equipment 2010 ADAM EQUIPMENT is an ISO 9001 2008 certified global organisation with more than 30 years experience in the production and sale of electronic weighing eguipment Products are sold through a world wide distributor network supported from our company locations in the UK USA SOUTH AFRICA and AUSTRALIA ADAMS products are predominantly designed for the Laboratory Educational Medical and Industrial Segments The product range is as follows Analytical and Precision Laboratory Balances
6. emove the transit rod before use Press the handle down only far enough to release any pressure on the transit rod then pull the transit rod free 7 Adam Equipment 2010 O 2 Insert split pin Once the roller pin is installed fit the split pin here Insert roller pin Roller pin Once the roller pin is a installed the chain is Lau the hole Unloading Plate 3 Pass the chain through the roller pin and then secure to the unloading pas Chain 4 Push the handle down to remove the transit rod Push down the handle to relieve pressure on the tranist rod and then remove the rod Fig4 8 Adam Equipment 2010 2 1 AE 402 ASSEMBLY Fig 5 Rear view of AE 402 Indicator Fit the PTS to Indicator cable as shown in the picture below 5 pin connector fitted here 9 Adam Equipment 2010 The Indicator bracket is fitted to the PTS using 4 x M4 screws as the picture below shows these should be tightened using the Allen Key supplied M4x6 Screws 4 places Fig 7 The Indicator cable goes through the hole on the bracket and connects to the Indicator using the 7 pin connector 10 Adam Equipment 2010 7 pin connector fitted here The AE 402 indicator is placed into the mounting bracket and secured using the two plastic fasteners as shown below Plastic fasteners used to secure Indicator to the bracket 11 Adam Equipment 2010 3 0 CALIBRATION The PTS is factory calib
7. rated please refer to the user manual for the indicator supplied AE 402 when further calibration when required 12 Adam Equipment 2010 4 0 TROUBLE SHOOTING No Problem Cause Solution Forks cannot ascend to 1 the maximum height Inadequate hydraulic oil in the chamber Refill oil chamber See Figure 10 No hydraulic oil Refill oil chamber See Figure 10 Oil is not clean Forks can not be Change oil 2 Foot pad screw too tight so that the valve remains open raised Adjust bolts or screws See Figure 11 There is air in the hydraulic oil chamber Vent the air Position of the goods are to one side of the truck Relocate load 3 Forks can not descend o Foot pad screw is not in the correct position Adjust bolts or screws See Figure 11 4 Oil spillage Aging or damaged seals Call for Service Forks descend when The oil could be unclean Change the oil 5 the trigger is not in Some parts of the hydraulic system are damaged Vent the air descend position Call for Service gt Remove Plug to Fill n Oil Chamber Foot Pad Adjust the screw position so it does not release the pump Lock with the nut 13 Adam Equipment 2010 O 5 0 MAINTENANCE e Please check the oil every six months we suggest you use hydraulic oil ISO VG32 e Whilst in transit air may enter into the hydraulic pump this may result in the forks not raising when first used Please