1. Kb 2400 Baud rate range 1200 2400 4800 9600 u Press For example b 4800 9 Press 1 10007 No 1 setpoint output Weight lt 1000 displayLO 10 Press K 2000 No 2 setpoint output 1000 lt Weight lt 2000 display OK Weight gt 2000 display HI x Seer oe Press to confirm configurations and go to calibration menu Note one time accumulation is allowed for weighing once Following accumulation is allowed for weighing only when displayed value is below 20 d yx Optional LO OK HI and two setpoint output PCB yx Press key for two seconds LCD display for LED are turned on A1GB L 7 Calibration Calibration should be done after setting the parameters a 1 Press KCAL SP Enters calibration Press gt KCAL 00 Zero the scale 2 Press K J Starts zero calibration and wait for calibration to K 3000 complete 3 K S Load the standard Starts calibration and wait for calibration to weight for F S on the complete platform press DW PJ Pallet Jack Scale 8 Pressed key three times during calibration or configuration The indicator will display To view the A D counts press the gt key when K A d is displayed press the key to return to weighing mode 8 Zero When the weight is stable Press 0 lt key for two seconds to set the zero point and zero the display the gt 0 status LED is turned on 9 Tare 9 1 Digital tare press key set
2. Pallet Jack Scale DWP PJ DWP PJ P User Manual 1 Model DWP 4400PJ Pallet Jack Scale 2 Accuracy Class III n 5000 3 Sample Rate 10 times second 4 Load cell sensitivity 1 5 3mV V 5 Scale interval 1 2 5 10 20 50 for option 6 Display 6 bits LCD 6 state indicating signals 7 Power supply Battery DC6V 4AH 8 Operating temperature humidity 0 40 C lt 90 RH 9 Transporting temperature 20 50 C pmen MM wide fork 1210 DW PJ Pallet Jack Scale 1 a Take out the handle from the package and put the release latch all the way down Mount the handle onto the pallet jack b First take out the lock of the handle axis c Then slide the axis out so the handle can be inserted DW PJ Pallet Jack Scale 2 d Insert the handle and slide in the axis e Place the axis lock back in f Put the chain through the whole on the axis and straight down DW PJ Pallet Jack Scale 3 g Press the paddle and insert the end of the chain into the paddle slot You can adjust the screw at the end of the chain to adjust the tightness of the handle h Press down the handle and take out the safety lock DW PJ Pallet Jack Scale 4 1 Introduction Simple operation Keyboard calibration and configuration Weighing up to 1 15 000 divisions Excitation voltage DC 5V Up to 4 350 Q load cells can be used Manual or automatic memory accumulation facility High R
3. When the battery is capacity less than 20 the display will start to blink power off the indictor to avoid over discharging battery or connect the external main Power supply When the battery capacity lt 10 the indictor automatic turn off to avoid battery over discharge In auto power off mode If weight is stable and no key operation for more than gt 3 mints The indictor displays to conserve battery When auto power off setting is action If weight is stable and no key operation gt 30 mints automatic turn off power A full charged battery life is approximately 30 hours 16 Unit of weighing kg and lb DW PJ Pallet Jack Scale 11 kg or Ib is selectable The unit of weighing is kg normally You can change it to Ib by pressing and holding key 2 seconds at least 17 Connection to Mini printers Connect serial port printer Type Up 16TS as follows Indicator Serial Port Printer 9 pin hole 25 pin needle 3 TXD 2 5 GND 7 Note Before connection to printer communication address is set as Adr 01 baud rate is set as b 2400 Print operation with serial port printer is as follows 17 1 Print at weighing status weighing data gt 20d and display is stable press weighing sheet is printed out The second printing can be operated only when the weighing data is back to lt 20d 17 2 Accumulated print at weighing status press thenpress accumulated printing can be operated 17 3 Set to be auto
4. esolution x10 Display Selectable digital filtering Selectable automatic power off 6 bit Display 0 8 inches LED Selectable display resolution 1 2 5 0 1 0 2 0 5 0 01 0 02 0 05 0 001 0 002 0 005 1 0 20 50 100 200 500 0 10 0 20 0 50 0 010 0 020 0 050 RS 232C The interface optional RS 485 interface 1200 2400 4800 9600 Baud rate continuous ASCII data output External Power supply 230V 115V AC Internal rechargeable 6V DC Battery Operating temperature 0 C to 40 C Storage temperature 25 C to 55 C Relative humidity lt 85 non condensing Dimensions 256mm wide x 165mm high x130mm deep 2 keypad functions OFF Off function ON On function Manual accumulation function Function selection during normal operation and configuration DW PJ Pallet Jack Scale 5 gt Move the flashing digit to the right during configuration or setting Preset tare t The display is temporarily set to high resolution increment the flashing digit during configuration or setting preset tare 0 lt Zero the display set the zero point or enter a tare value 3 Display status KAC Mains power is applied to the indicator gt T A weight has been tare display is showing the net weight dp Battery capacity less than 30 0 The scale is Zero AUTO The automatic accumulation function is active Ch 4 The Weight is stable Ib Co o The unit of weighing is Ib K 0 10 The display is
5. et following configuration parameters 1 Self test from In power off states press 0 lt key and UEr 7 9 0 to LON turn on power segment check and display K91K 01 KUE 7 9 edition No 1 5 second Press KCAL SP Enter of the scale Press K SEt Enter the configuration setting modal The number of scale divisions selected d J Press t K 0 001 0 002 0 005 10 20 50 100 200 500 0 10 0 20 0 50 0 010 0 020 0 050 1 2 5 0 1 0 2 0 5 0 01 0 02 Press ft Kd 0 1 0 05 Forexample d 0 1 Press K 6000 Sets scale F S Press gt 000000 Press gt Press gt Press t Press t 001000 DW PJ Pallet Jack Scale 7 Press t K002000 For example F S 3000 003000 Press 1 KFLt 10 Sets digit Filter parameters 00 99 Press gt KFLt 00 The display will updata faster and filter faster as The filter parameter is changed from 99 00 For example FLt 00 Press KAUtPOO Sets Automatic Power Off function Press gt KAUtPOO AUtP 00 Not automatic power off Press gt KAUtPOO AUtP 01 Automatic power off digit express the choice of zero trace range 1 9 1 0 4d 2 08d 3 1 2d 4 16d 5 2d 6 2 4d 7 28d 8 3 2d 9 3 6d decimal digit express the choice of zero set decimal digit 0 no zero set at start operation Press t decimal digit 1 zero set at start operation 20 FS KAUtP10 For example AUtP 10 AUtP 10 when leaving the factory 7 continuous output Adr 00 Press
6. matic accumulation status i e automatic print At weighing status weighing data gt 20d and display is stable weighing sheet is printed out The second printing can be operated only when the weighing data is back to lt 20d and more weight is loaded Attached with print sample Normal print accumulation print NO 1 serial No NO 9 number of accumulation Gross 3940kg gross weight W 8225kg accumulated weight Tare 2000kg tare weight Net 1940kg net weight 18 Precaution Indicator should be far away from heat resource while using Do not place the indicator in the dusty surroundings or the site vibrant Cannot use full capacity Over load stops hitting platform support is not permitted To ensure to keep out of chemical erosion Operating temperature range will be 10 50 C relative humidity is no less than 85 without any corrupt gas in air Never pour the water into the indicator Housing head pallet wire connector should be sealed entirely Users do not open sealed device or connect with wire without any expert advice In case any malfunction of indicator occurs please sent the indicator for maintenance The indicator will charge the internal battery at all times when it is connected to the main power DW PJ Pallet Jack Scale 12
7. tare with gt and I t key then press gt 0 lt key the input data is tare Tare status LED is turned on 9 2 Acquire tare When Tare status LED is off and the weight is stable press the 0 lt key to acquire tare and switch to net mode The Tare status LED is turned on 9 3 Remove tare When Tare status LED is on press gt 0 key will switch to gross mode and removed tare The Tare status LED is off 10 Manual weight accumulation When weight is stable press key to accumulation the current weight to the total weight The total number of accumulation will be displayed for Kn 12 1 5 seconds 11 High resolution display mode In this display mode press t switch to high resolution display mode 10 times normal display The last decimal point is light on Press t key return to normal weight display mode 12 Automatic Memory Accumulation Selection of manual automatic accumulation function Selection of manual automatic print function Selection of animal scale peak value retain and counting function Displaying Kn 12 to display times of accumulation DW PJ Pallet Jack Scale 9 Press KAUt O the selection of manual automatic accumulation AU 0 manual accumulation AUt 1 automatic accumulation and print when weight is added KAUTO indicator is lit AUt 2 automatic memorize displayed value when weight is added Accumulate and print final stable values af
8. temporarily set to high resolution 4 Technical Description 4 1 Load cells to indicator D B 9 Pin plug Indiator Load cell 5 S El t Excitation 6 D 8 9 E5 Excitation DO Rs Sienal 8 Signal E GND GND Shield3 GND Shield 4 2 Load cells to indicator 5 Pin plug Indi cat or Load cel JE TL Exci tati on ISo Zone Si gnal 9 3 anni Si gnal Sd E Exci tati on aD5 D 5 4 3 RS 232C D B 9 Pin 3 Output TXD Pin 5 Signal Ground GND DW PJ Pallet Jack Scale 6 4 4 Continuous ASCII RS 232 data output format 4 4 1 Automatic Output 4 4 1 1 Address Adr 00 The ASCII data format is X1 X2 X3 X4 X5 X6 lt stx gt X1 X2 X3 X4 X5 X6 lt cr gt X1 X2 X3 X4 X5 X6 is weight data If the weight is K 100 00 kg the continuous output is 00 001 00 001 4 4 1 2 Address Adr 99 The ASCII data format is X6 X5 X4 X3 X2 X1 lt stx gt X6 X5 X4 X3 X2 X1 lt cr gt X6 X5 X4 X3 X2 X1 is weight data If the weight is K 100 00 kg the continuous output is 100 00 100 00 4 4 1 3 Manual and Automatic Printing Output Address Adr 01 98 5 Power In power off states press ON key turn on the indicator The indicator will check the LED and display battery capacity KbPt 82 for 1 5 second 6 Configuration Connect load cells to the indicator and s
9. ter load down to below 20d KAUTO indicator is lit AUt 3 dynamic weighing method At weighing gt 20d the buzzer sounds du and lock is displayed for 6 seconds When a new data is fixed lock is displayed again for 6 seconds Then lock is released for weighing lt 20d automatic accumulation and print Suggest FLt gt 30 AUTO indicator is lit AUt 4 peak value fixed weighing method At weighing gt 20d the buzzer sounds du and lock is displayed When weighing lt 20d fixed data displays with flash automatic accumulation and print Lock can be released by pressing any key KAUTO indicator is lit AUt 5 dynamic weighing method Manual accumulation and print AUt 6 peak value fixed weighing method Manual accumulation and print AUt 7 counting function note Ra KAUt 0 digit displays with flash Press i KAUt 7 Sets F S Press t 1 KAUt 1 Move binking digit to the right bit Press 11 KAU 2 KAUt 3 e g AUt 3 expresses dynamic weighing method note 1 sampling When net weight on scale is zero tare can be removed by pressing tare key if net weight is not zero the sample which must be lt 200 pieces i e between 1 to 199 is put on the scale Press and t input quantity of the sample e g 30 KCnt030 is displayed Press 1 confirm the completion of sampling Weighing status is redisplayed Sampling is memorized even with power off BER place sample Bun place selected sample weight 27 quan
10. tity 30 press aa K Cnt000 ready to input sample s quantity press Cnt000 decimal digit display with flash press 7 KCnt010 press t Cnt020 press t Cnt030 K 27 display sample s weight 27 is a confirmation key sample collectio DW PJ Pallet Jack Scale 10 I Teompleed press t KC 30 display sample s quantity K t is change over key between weight and quantity display 2 Counting operation place the object on scale weight is displayed press KC 255 is displayed and the display changes over to the quantity of the object When the display is stable press accumulate the weight and quantity Accumulation can be done only at counting status press An 4 display after 1 5 seconds KC 255 3 accumulate inquiries and delete both at weighing stage and counting status press t L1085 display accumulated weight 4 digits lower 1085 rt eos press gt 0 lt KC 0 delete accumulated quantity 13 Clear memory Press gt 0 key If the memory has previously been cleared the display will show Kn 0 followed by zero weight when the key is pressed 14 How to set datum Press gt key move and blinks the current digit to Press t key increment the current digit to the next available value 15 Battery capacity When the indictor is being power on off battery capacity will be displayed KPBt 85 for1 5 seconds

Download Pdf Manuals

image

Related Search

Related Contents

Falcon 350 Chargrill User Instructions for G350/10  Butler 4056/4056C    manuel d`installation, utilisation et entretien cuisinières à gaz  NOTA: El Anexo II de la presente Ley fue publicado en el BOCBA Nº  NCP1605 152 W Forward Evaluation Board User`s Manual - Digi-Key  Samsung HC6147BX دليل المستخدم  取扱説明書 - プロスペック|PROSPEC  PCA T5 ECO lp 14–80 W 220–240 V 50/60/0 Hz  Ektron CMS400.NET Administrator Manual  