Home
SeeTool - Solutions for KNX
Contents
1. DETECTOR Automatic mode operation e The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold It is automatically switched OFF when no movement is detected in the room and preset delay time has passed e Delay time is adjustable by ETS software Default is 25 min e The brightness threshold is also adjustable by ETS software Default is 300 lux service e for vour Schneider y 06 10 Application 3 0 0 0 0 4 amp Electric customer ISC02072 EN 6
2. SeeTool Solutions for KNX Office building segment Application 3 0 0 0 0 4 Movement dependent automatic light control 2 room solution Schneider Electric Application 3 0 0 0 0 4 Movement dependent automatic light control 2 room solution fly Lighting control functions The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold It is automatically switched OFF when no movement is detected in the room and preset delay time has passed Application areas The application is defined for two single room offices with basic requirements on comfort for lighting control It is also usable in all types of infrequently visited areas and occasionally used rooms as it offers basic simple lighting control which switches the light automatically dependant on people s movement gt Energy savings Lights will not remain on all night or even when not needed Energy savings are achieved by turning ON and OFF the lights automatically This reduces the time for the lights turned on and can lead to savings of 40 compared to installations without automatic function gt Future proof The application is prepared and defined for integration into a Building Management System if required through the open technology communication network gt Lighting Flexibility For optimised cost the amount of units is reduced to a minimum but a
3. aircase timer delay time will be retriggered by every detected movement when the light is on The light will be switched off if no movement has been detected within the specified time fine tuning Parameter page Parameter Value Block 1 general gt Times Time base for staircase timer 1s 1h 1 min Block 1 general gt Times Time factor for staircase timer 1 255 25 Delay time Time base x Time factor The light will only be switched ON by movement if the brightness in the room is below the specified brightness threshold Note that the brightness is measured at the installation place of the detector Parameter page Parameter Value Block 1 general gt Brightness Brightness threshold 10 2000 lux 300 Power failure behaviour Relay state after bus voltage failure no change relay remains Relay state after bus voltage recovery opened light is OFF Application 3 0 0 0 0 4 ly Movement dependent automatic light control 2 room solution Technical specifications User manual The user manual provided for the application is an end users training material and can be installed at site when final submissions made Please do no forget to cut out this quick guide for the user and attach to the wall next to the entrance to the room Also make sure the customer is aware of the installed applications function Quick guide THIS ROOM IS EQUIPPED WITH AN AUTOMATIC MOVEMENT
4. ct Channel 2 1 bit Brigin eee eee 1 1 12 lt Status feedback Channel 2 1 bit S ettin S Block 1 general gt Times Devi lecti g Time base for staircase timer 1 min aie i iad bh Aakre asus Time factor for staircase timer Sule salsaon pi GENENE EO 1 255 25 Channel 1 General Status information active status resp object 7 Relay state after bus KNX PIR 180 2 20m Room2 voltage recovery opened O Switch object 1 Block 1 1 bit gt 1 1 11 Channel 2 General 109 Status feedback Safety pause 1 bit lt 1 1 12 Status information active status resp object Relay state after bus Block 1 general gt Brightness voltage recovery opened Brightness threshold 10 2000 Lux 300 Block 1 general gt Times Time base for staircase timer 1 min Time factor for staircase timer 1 255 25 Group addresses Address Name proposal Function 1 1 1 Room 001 Light On Off Light on off by the movement detector 1 1 2 Room 001 Light Status Feedback from actuator On Off 1 1 11 Room 002 Light On Off Light on off by the movement detector 1 1 12 Room 002 Light Status Feedback from actuator On Off Application 3 0 0 0 0 4 ly Movement dependent automatic light control 2 room solution Technical specifications Fine tuning Some parameters can be changed to fine tune the solution to the building and specific requirements Parameter which may need to be adjusted are listed below our recommendation in brackets KNX PIR 180 2 20m The st
5. ded to be installed on the wall at a height of 2 20m Application 3 0 0 0 0 4 ty Movement dependent automatic light control 2 room solution Technical specifications Wiring diagram KNX PIR 180 2 20m flush mounted WDE002959 KNX PIR 180 2 20m flush mounted WDE002959 Room 2 System component Presence detection KNX Presence detection KNX _ Switch actuator REG K 2x230 16 with manual mode MTN647393 Power supply Q Room 1 Q Room 2 things work together Application 3 0 0 0 0 4 Movement dependent automatic light control 2 room solution Technical specifications Configuration The ETS tool is used to set the parameters for the devices in the application and to define the functional relationship between the devices by group addresses The following parameters and group address relations must be set and assigned The parameters should be set first and in the described order The parameters which can be changed to fine tune the application are described further on KNX PIR 180 2 20m Room1 Switch actuator REG K 2x230 16 O Switch object 1 Block 1 1 bit gt 1 1 1 1 1 1 gt 0 Switch object Channel 1 1 bit 109 Status feedback Safety pause 1 bit lt 1 1 2 1 1 2 lt 3 Status feedback Channel 1 1 bit Block 1 general gt Brightness 1 1 11 gt Switch obje
6. llows maximum of flexibility when walls are removed and rooms are combined Reliability Design planning and installation documents EN 15232 are pre defined which makes the entire building process faster and more reliable A class solution User documents and descriptions are prepared to assist in user training The application works as an individual stand alone room control unit and can be installed used alone or combined with the entire network tested amp validated Application 3 0 0 0 0 4 ty Movement dependent automatic light control 2 room solution Technical specifications Functions The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold It is automatically switched OFF when no movement is detected in the room and preset delay time has passed Delay is adjustable by ETS software Default is 25 min functions The brightness threshold is also adjustable by ETS software Our recommendation is 300 lux Components The application consists of two movement detectors wall mounted and one DIN rail switch actuator mounted in the cabinet or close to the room MTN647393 KNX Switch actuator REG K 2x230 16 with manual mode Design ranges Frames not included Other designs and colours available EXXACT WDE002959 2x KNX PIR 180 2 20m flush mounted Installation Movement detector recommen
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 www.irobot.com TFAN - Garantia 32x46,5 Manual de Utilização powerTWO User Manual Force Plate Actimeter® User`s Manual SKP16C28 User`s Manual Operators Manual Copyright © All rights reserved.
Failed to retrieve file