Home

C320 Turbo/PCI User`s Manual

image

Contents

1. 3 12 Intellio C320Turbo PCI User s Manual WWW moxa pro Software Installation 3 Type A Windows 95 in the Location field 3 Selct Other Devices and click Next gt and click OK The system will start reading the files from the diskette 4 Clink on the Finish button Update Device Driver Wizard 5 Type A Windows 95 and click OK The system will start reading the files from the diskette Intellio C320Turbo PCI User s Manual 3 13 www ipc2u ru www moxa pro 6 Click Next gt Add New Hardware Wizard 7 Click Next gt Add New Hardware Wizard 3 14 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro Software Installation Port Configuration Stage This stage displays the C320Turbo PCI Installation dialog box for the port configuration Here you can map the MOXA ports to the system COM numbers C320Turbo PCI Installation PCI bus number is 0 and device number is 10 COM Number cows IV Auto Enumerating COM Number Advanced Settings In the C320Turbo PCI Installation dialog box you can map the physical ports to COM numbers in two ways depending on the Auto Enumerating COM number check box Sequential Port Mapping Enable Auto Enumerating COM number Specify the COM number of the first port and subsequent ports are mapped to conti
2. Extensive M odule Basic M odule Surge lsolation Protection To prevent the boards from damage caused by lightning or high potential voltage TVSS Transient Voltage Surge Suppressor and high potential difference protector technologies are introduced in some connection options to protect the multiport controller This is critical to harsh environment such as factory severe weather such as lightning or other high interference situations Status Indicator The status of the communication lines is displayed on a row of diagnostic LED indicators on the front panel of the external module including TxD RxD DTR DSR RTS CTS and DCD signals Major Operating System Support It supports most popular O S platforms like Windows NT Windows 95 98 SCO UNIX OpenServer UNIX SVR4 2 Linux MOXA device drivers feature easy installation configuration and better performance In this manual chapters for MOXA Windows NT Windows 95 98 and UNIX device drivers are included For other systems not mentioned please contact Moxa dealer distributor or Moxa or visit the MOXA Web site for more information about newly available device drivers Intellio 20 User s Manual 1 3 www moxa pro Powerful Serial Comm Developing Tools For application development MOXA provides the easy to use while powerful serial communication library including PComm under Windows NT Windows 95 98 and extended UNIX system calls You can
3. 10 singal pin Cable C320 Turbo PC1 Basic Module C Plug the other DB25 female end into the Basic Module s DB25 connector Warning Do not use a 25 signal pin cable to connect the Intellio C320Turbo PCI Control Board to the Basic Module when using the power adapter as this will cause power crash One power comes from the power adapter while the other power comes from the Intellio C320Turbo PCI Control Board D Connect the power adapter to the Basic Module Keep the Basic Module s power switch in the OFF position If Extensive Module s is are also required keep the Basic Module s power switch in the OFF position until all necessary Extensive Module s is are installed E Install the power adapter to a power source either 110V or 220V AC Adjustment to the AC power specs is done automatically Step 8 If one more Extensive Module is required plug the DB37 to DB37 male end of the shipped 1 meter cable into the DB37 female connector on the rear panel of the Basic Module and the other end of the cable into the DB37 male connector on the rear panel of the Extensive Module If more Extensive Module is needed connect the next Extensive Module to the previous one as described above Intellio C320Turbo PCI Users Manual 2 7 www ipc2u ru www moxa pro To mount the module s on the industrial standard 19 rack Rack Mount Kit including two L type plates and eight screws should be applied
4. Port Name COMS Port Status Open Baud Rate bps Data Bits Communication Parameter Flow Control 38400 apsed time 00 02 04 8 RTS Flow Control ON CTS Flow Control ON r Tx History Intellio C320Turbo PCI User s Manual 4 3 www moxa pro Terminal Emulator The Terminal Emulator features multi windows and supports terminal types of VT100 and ANSI You can transfer data interactively send pattern periodically or transfer file using ASCII XMODEM YMODEM ZMODEM and KERMIT protocols xenix386 login Password Welcome to SCO XENIX System V ico M44_38400 None 8 1 Dumb Terminal 0123456789 abcde fghij0123456789 abcde fghij0123456789abcdefghij01Z3 0123456789 abcde fghij0123456789 abcde fghij0123456789abcdefghij01Z23 0123456789abcde fghij0123456789abcde fghij0123456789abcdefghij01Z3 0123456789 abcde fghij0123456789 abcde fghij0123456789abcdefghij01Z3 0123456789abcdefghij0123456789abcdefghij0123456789abcdefghij0123 0123456789abcdefghij0123456789abcdefghij0123456789abcdefghij0123 0123456789abcdefghij0123456789abcdefghij0123456789abcdefghij0123 0123456789abcdefghij0123456789abcdefghij0123456789abcdefghij0123 0123456789abcdefghij0123456789abcdefghij0123456789abcdefghij0123 0123456789abcdefghij0123456789abcdefghij0123456789abcdefghij012 0123456789abcdefghij0123456789abcdef 4 4 Intellio C320Turbo PCI User s Manual www ipc2u ru WWW moxa pro www ipc2u ru Serial Pro
5. 2 10 Software InstallatiO i otn saaa asi caste sis deines 3 1 Windows INT oro pe p e repre pee Hebdo E 3 1 Installirig Driver cerco ccu peret ecc epe neve a ut idea oc aa js 3 2 Configuring Board and POr t celere rre riget oett er PUE p x Eget gai aaa 3 7 Adding Removing Boarc x ete eg tete tette a si aa peregi d 3 9 Bore peur 3 9 REMOVING DIVE ER 3 9 WV ING OWS 5 SB i essent ten esto Eier OD wena tens eee ome e 3 10 Installing iii Errare 3 10 Configuring Board and Port eene nennen nennen 3 19 Updating driver 5 dp niega eite eiie 3 23 REMOVING GVT os ERE 3 23 Bip am TETTE 3 24 Installiig DIIV F iz EE 3 24 MOXA TTY Device Naming Convention cc cccccccessseceeeeeeeeeeeeeaeeeeaeeseeeeeseaeeesaeeeeeeeeeaees 3 27 Administration Utility 3 28 Checking Board Initialization 5 3 34 Setting MOXA Ports to Terminal sess 3 34 www ipc2u ru www moxa pro Serial Programming TOOIS cccceecceeseeeeesseeeesseeeeeseeeeesseeeeeseeeeenseeeeenens 4 1 Windows NT Windows 95 98 4 1 Installation eR enr e EC 4 1 PComm Programming Library enne nnne nennen 4 2 ule 4 2 UNDE tette t Udo ta aden a cm pupa a cnc D a Ra DR RR aes 4 5 Programming the MOXA Ports ener enne nnns en nennt 4 5
6. MOXA UNIX Device Driver Installation Ver x x Please select one of the following OS 1 SCO UNIX 2 UNIX SVR4 2 3 XENIX Select Please type 1 for SCO UNIX 3 2 x SCO OpenServer or SCO Open Desktop Type 2 for UNIX SVR4 2 UnixWare or MITUX Type 3 for XENIX Please select one of the devices where the driver diskette files put 3 24 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro Software Installation 1 dev fd0135ds18 A 1 44MB 2 dev fd096ds15 A 1 2 MB 3 dev fd1135ds18 B 1 44MB 4 dev fd196ds15 B 1 2 MB 5 Hard Disk tmp moxa Select Please type 1 2 3 4 or 5 Step 6 MOXA Multiport Board Installation Utility dialog will show for driver installation When finished press any key to continue SCO UNIX or SCO OpenServer or XENIX You will be prompted to rebuild kernel at this moment and you are recommended to do so unless you need to install other driver Please type After kernel rebuild please shutdown the system on your own UNIX SVR4 2 or UnixWare or MITUX You will be prompted to shutdown the system on your own for kernel rebuilding and you are recommended to do so Step 7 Once the system reboots run mxadm to configure the board and port Select and open Basic Configuration to do the basic board and port configuration You may further optionally select and open Advanced Configuration to do the advanced settings Select and open Board
7. O O Multiport Controller e o o o oo o o 0 o O L type Plate Multiport Controller with Rack Kit installed Front View L type Plate Step 9 After making sure that each component has been correctly installed you are recommended to power on the Basic Module first and then power on the PC system secondly L type Plate L type Plate gt m Ga BENEEEEENH Ner Mutiport Controller with Rack Mount Kit installed Rear View a 05 Now the installation of the external Basic Extensive module is complete Continue to install the software driver explained in chapter 3 Operating LED Indicators After completing the installation and powering on the CPU Basic Module and the PC system check the two digit LED display on the CPU Basic Module These LEDs show the results of the system self diagnostic tests which are run by the CPU Basic Module after startup The CPU Basic Module will first test the ROM and RAM of itself and then UART Extensive Module s if present If any error is found the LED display will show one of the messages described in Troubleshooting chapter 2 8 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Hardware Installation If the first test passed the CPU Basic Module will then display Ld waiting for loading firmware from the Intellio C320Turbo PCI Control Board After loading the
8. www ipc2u ru www moxa pro Serial Programming Tools 3 MTCRTS This function only valid when hardware flow control is turned off see MHWFLOYW is used to turn RTS on or off Syntax for SCO UNIX XENIX define MTCRTS 0x403 define TurnON 1 define TurnOFF 0 ioctl moxa fd MTCRTS TurnON ioctl moxa fd MTCRTS TurnOFF Syntax for UNIX SVR4 include lt sys stropts h gt include lt sys sysmacros h gt define MTCRTS 0x403 define TurnON 1 define TurnOFF 0 struct strioctl ioc int setting setting TurnON or TurnOFF ioc ic cmd MTCRTS ioc ic timout 0 ioc ic len sizeof int ioc ic dp char amp setting ioctl moxa fd I STR amp ioc 4 MTCDTR This function only valid when hardware flow control is turned off see MHWFLOYW is used to turn DTR on or off Syntax for SCO UNIX XENIX define MTCDTR 0x404 define TurnON 1 define TurnOFF 0 ioctl moxa fd MTCDTR TurnON ioctl moxa fd MTCDTR TurnOFF Intellio C320Turbo PCI User s Manual 4 7 www ipc2u ru www moxa pro Syntax for UNIX SVR4 include lt sys stropts h gt include lt sys sysmacros h gt define MTCDTR 0x404 define TurnON 1 define TurnOFF 0 struct strioctl ioc int setting setting TurnON or TurnOFF ioc ic cmd MTCDTR ioc ic_timout 0 ioc ic_len sizeof int ioc ic_dp char amp setting ioctl moxa_fd I STR amp ioc 5 MLOWATER Sometimes the application so
9. DCD 5 2 Intellio C320Turbo PCI User s Manual www ipc2u ru f v Straight through Cable D Cable Wiring 1 OV tA 1 OV tA 4 DCD GND DTR RTS CTS TxD RxD PONDRAN TxD RxD RTS CTS DSR GND DCD i PC COM2 port Serial Printer Terminal or any DTE Device DTE Device DB25 Male Connector TxD RxD RTS CTS DSR DTR GND DCD www moxa pro Connection Option and Cable Wiring IN Null Modem Cable C32047T 5 d C32047T DTE Device PC port Serial Printer Terminal or any DTE Device PON DB25 Male Cable Wiring i DB25 Male Connector i Connector TxD 2 2 TxD RxD He ieee RxD RTS 4 4 RTS CTS 5s CTS DSR 6 6 DSR DTR 20 39 DTR GND T am 7 GND DCD 8 8 DCD D L PC COM2 port Serial Printer C32047T v i Terminal or any DTE Device C32047T DTE Device DB25 Male Cable Wiring DB9 Male Connector Connector TxD E 2 2 RxD RxD 3 3 TxD RTS 4 8 CTS CTS 5 7 RTS DSR 6 4 DTR DTR 20 6 DSR GND 7 5 GND DCD 8 1 DCD Intellio C320Turbo PCI User s Manual 5 3 www ipc2u ru www moxa pro Type 2 Connecting UART Module to a DCE device IR Null Modem Cable A C32045T 71T b 4 _ Modem y or any DCE Device C32045T 71T DCE Device DB25 Female Cable Wiring i DB25 Female Connector Connector RxD 2 2 i RxD TxD 3 2 3 TxD CTS 4 4 CTS RTS a RTS DTR 6
10. 0 C320 Turbo PCI 25 singal pin Cable Basic Modde A Set the Basic Module power switch to the OFF position This is absolutely necessary when installing or removing the cable the Basic Module or the Extensive Module s Power should not be switched on until you installed all components B Plug the DB25 male end of the shipped 2 meter 25 signal pin cable into the connector on the rear panel of the Intellio C320Turbo PCI Control Board Refer to the chapter 5 for the cable pinout details C Plug the other DB25 female end into the Basic Module s DB25 connector With power adapter for range extension external power condition In case of range extension or external power requirement you need a power adapter A Set the Basic Module power switch to the OFF position This is absolutely necessary when installing or removing the cable the Basic Module or the Extensive Module s Power should not be switched on until you installed all components B Plug the DB25 male end of the shipped 2 meter 10 signal pin cable the link cable comes with long range extension kit or the one fabricated according to the pinouts in chapter 5 into the connector on the rear panel of the Intellio C320Turbo PCI Control Board 2 6 Intellio C320Turbo PCI User s Manual WWW moxa pro Hardware Installation Extensive Module uu 272 Power Adapter
11. Extended UNIX loctl Commands ssssssssssssseeeeeeneen nennen nnn nenne 4 5 ule EE 4 11 Connection Option and Cable Wiring eere 5 1 RS 232 Cable Wiring for C32045T C32047T C320717T 5 1 RS 422 Cable Wiring for 2061 320657 5 7 RS 232 Cable Wiring for C32080T 81T 82T 83T amp CN20040 5 10 2020 Link Gables eoo daa ddan ea veio qu qe re one a te 5 14 Troubleshooting e ottenere heir nest ss iu eta ka icu 6 1 General TrouDlesnGoung i toto trade o ee i ie i PR a uite es 6 1 c r M 6 5 Windows TERRE 6 7 RUIN ordei Suniel ai aa ii a k i a i d i 6 8 Technical RerererQe usui aa asa a i aa ii ce aaa des A 1 SDECINCALANSi sns a eae A 1 PAS n D ai is S a a i i O cu esee i i i a a L eb A 5 n 5 TI550C in UART Basic Extensive Modules A 6 www ipc2u ru www moxa pro www ipc2u ru Overview 1 Introduction This manual covers both the hardware and software installation and configuration of C320Turbo PCI which is the member of the Intellio Family In addition the professional serial comm tools PComm under Windows NT and Windows 95 98 and extended UNIX system calls and utilities are introduced The excellent featu
12. TxD RxD UART CTS RTS DTR DSR DTR DCD testing etc for the MOXA boards and ports to verify correct operation of both the software and hardware To be tested Test Report C320T 16 PCI BR o evi 18 Bustt JR C320T 16 PCI Dev 18 Bus f 0 IRQ 12 Mem FFEECOD0 Communication Parameter 460800 None 8 1 Driver Version 4 9 IOS Version Windows 4 0 Build 1111 Internal Loopback Test Ready 4 2 Intellio C320Turbo PCI User s Manual www ipc2u ru WWW moxa pro www ipc2u ru Serial Programming Tools Monitor for MOXA boards under Windows NT Only A useful port status monitoring program allows you to watch the selected MOXA COM ports data transmitting receiving throughput and communication line status which are updated and displayed on the screen at every time interval In addition you may click on one of the specific displayed port in order to see the current communication parameters and status of that port d PComm Monitor Port Count Tx CPS Tx Count Rx CPS Rx RTS CTS DTR DSR DCD 126976 1024 125264 1010 o o o o 126976 1024 126976 1024 o o o O 125952 1015 126760 1022 o o o O 125952 1015 126300 1018 o o o o 125952 126032 o o o o 128000 125828 o o o 126976 i 126976 1024 125440 1011 o o o o 0 eee m Tx bytes 1s 2 o o o o 00 o o Rx bytes 1s m History
13. 6 DTR DSR 20 77 i DSR GND Toa GND DCD 8 8 DCD N Straight through Cable b d Modem C32071T d NW i or any DCE Device C32071T DCE Device DB25 Male Cable Wiring DB25 Female Connector Connector TxD 2 M 33 2 RxD RxD 3 3 TxD RTS 4 4 CTS CTS 5 5 RTS DSR 6 6 DTR DTR 20 20 DSR GND 7 7 GND DCD 8 8 DCD 5 4 Intellio C320Turbo PCl User s Manual www ipc2u ru www moxa pro Connection Option and Cable Wiring Type 3 Connecting UART Module to a DTE device with 3 pin wiring If the Hardware flow control feature is set to ON you must loop back or short the RTS with CTS and DSR with DTR DCD on MOXA site indicated in dash lines of the following diagrams If the Hardware flow control feature is set to OFF you could just leave RTS CTS DSR DTR DCD open ignoring the connection indicated in dash lines m port Serial Printer b C320451 71T y 1 Terminal or any DTE Device C32045T 71T DTE Device DB25 Female Cable Wiring DB25 Male Connector i Connector RxD 2 2 TxD TxD 3 3 RxD GND 7 7 i GND RTS 5 5 CTS DTR 6 6 DSR DSR 20 20 DTR DCD 8 8 DCD i N PC port Serial Printer 21 y Terminal 2 any DTE Device C32047T DTE Device DB25 Male Cable Wiring i DB25 Male Connector i Connector TxD 2 2 i TxD RxD eG RxD GND i GND RTS 4 4 RTS CTS 5 5 CTS DSR 6
14. 6 DSR DTR 20 20 DTR DCD 8 8 DCD Intellio C320Turbo PCI User s Manual 5 5 www ipc2u ru www moxa pro www ipc2u ru C32047T C32047T DB25 Male Connector TxD RxD GND RTS CTS DSR DTR DCD 5 6 Intellio C320Turbo PCl User s Manual Cable Wiring OS gt 2110 amp port Serial Printer Terminal or any DTE Device DTE Device DB9 Male Connector RxD TxD GND RTS CTS DTR DSR DCD www moxa pro www ipc2u ru Connection Option and Cable Wiring RS 422 Cable Wiring for C32061T C32065T The following RS 422 UART Modules are designed for Intellio C320Turbo PCI C32061T UART Module providing 8 female RS 422 DB25 ports without isolation protection C32065T UART Module providing 8 female RS 422 DB25 ports with 2000V isolation protection which can prevent damage caused by high potential voltage C32061T 65T 2 3 14 16 7 4 5 13 19 RxD B TxD B RxD A TxD A GND CTS B RTS B RTS A CTS A 13 RTS A CTS A 19 7 GND 5 RTS B TxD A 16 4 CTS B 3 TxD B RxD A 14 2 RxD B E The DTR DSR and DCD signal lines not shown of the C32061T C32065T are internally shorted by design to meet certain software requirements The RS 422 transmission distance can reach as long as 4000ft The connection box needs an external power adapter to supply 5V DC power Either 110V or 220V
15. AC power adapter is selectable Intellio C320Turbo PCI User s Manual 5 7 www moxa pro www ipc2u ru The followings are operation modes for RS 422 RS 422 Point to point RS 422 Broadcasting C32061T 65T 3 TxD4 B 16 TxD A 2 RxD B 14 RxD A 7 GND RS 422 Device RxD B RxD A TxD B TxD A GND RS 422 with Handshaking C32061T 65T 3 16 2 14 7 5 13 4 19 TxD B TxD A RxD B RxD A GND RTS B RTS A CTS B CTS A RS 422 Device RxD B RxD A TxD B TxD A GND CTS B CTS A RTS B RTS A 5 8 Intellio C320Turbo PCl User s Manual C32061T 65T TxD B RxD B TxD A RxD A GND RS 422 Device 1 RxD B TxD B RxD A TxD A GND RS 422 Device N RxD B TxD B RxD A TxD A GND www moxa pro Connection Option and Cable Wiring RS 422 Impedance Matching When an electrical signal travels through two different resistance junctions in a transmission line the mismatch will sometimes cause signal reflection Signal reflection causes signal distortion which in turn will contribute communication errors The solution to this problem is to establish the same impedance at the line ends as in the line itself by terminating them with resistors It is normally sufficient when the value of the termination resistor equals the characteristic impedance of the transmission line The resistors should be added
16. BusNo x DevNo x at base memory XXX interrupt failure appears consult the Troubleshooting chapter complete and configuration However configuration are needed please refer to Configuring Board and Port for more configuration details Up to now the driver installation of Intellio C320Turbo PCI is successful including the board and port of the board and port the next section if changes Once the board and driver are installed and the driver restarts successfully you can start to develop applications with the PComm library See Serial Programming Tools chapter or the Microsoft Win32 API You can also execute any ready made application such Intellio C320Turbo PCI User s Manual 3 17 WWW moxa pro PComm utility Terminal emulator See Serial Programming Tools or HyperTerminal to transmit receive data as well as Remote Access Service to provide dial up networking capability 087 Tf multiple boards are installed at the same time the same scenario applies for the next boards except that no driver diskette is asked any more US Similarly if you want to add more boards and the driver has been installed before simply plug the Intellio C320Turbo PCI board and Windows 95 98 will automatically detect and install the required driver 3 18 Intellio C320Tuxbo PCI User s Manual www ipc2u ru www moxa pro Software Installation Configuring Board and Port If you already have install
17. CTS flowctr ttya11 A11 Disable ttya12 A12 Terminal Slow Enable Disable ttya13 A13 Terminal Slow Enable Disable ttya14 A14 Terminal Slow Enable Disable ttya15 A15 Terminal Slow Enable Disable ttya16 A16 Terminal Slow Enable Disable ttyal7 A17 Terminal Slow Enable Disable ttya18 A18 Terminal Enable Disable Feature In the Port Feature Settings sub dialog port feature Terminal is the only choice if On Board Line Discipline is set to Enable This is good for terminal application However if On Board Line Discipline is set to Disable port feature could be either Transparent or Terminal In case of Terminal all the tty line discipline jobs will be done on host which surely is a burden to the host In case of Transparent no time consuming tty line discipline is applied for the port Intellio C320Turbo PCI User s Manual 3 31 www moxa pro www ipc2u ru except flow control thus non terminal applications such as data acquisition will benefit from it e g gain better throughput and performance Response Three levels Slow Normal and Fast of port response time are designed for your need Ports with faster response time will consume more host CPU s resource while slower response consumes less resource The response time for those ports with normal or slow response can be further tuned by the response level in Performance Tuning menu In addition if the port feature is s
18. Module should have only 10 signal pins with the following pinouts Make the link cable carefully and precisely according to the following pinout otherwise you will risk damaging the Control Board and CPU Basic Module Pin No Signal Pin No Signal 2 DX 14 CLK 3 DR 15 FSX 11 CLK 16 FSR 12 FSR 24 FSX 13 DX 25 DR US You can connect the existing 10 signal pin cable to a 25 signal pin cable to form a longer 2 segment cable to extend the connection distance up to 100 meters 328 ft Intellio C320Turbo PCI User s Manual 5 15 www ipc2u ru www moxa pro 5 16 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru 6 Troubleshooting General Troubleshooting Common Intellio C320Turbo PCI problems and possible solutions are listed below in addition to those operating systems specific ones If you still have problems contact your dealer or Moxa for help Or report it using Problem Report Form at the end of this manual to your dealer at once for technical support 1 MOXA PCI board can not be detected by the MOXA driver while installing the driver Hardware causes and solutions a The board is not installed or missing absent Please install it b The board is not properly plugged in the system If that is the case then re install the board and make sure that it fits well in a 32 bit PCI slot this time Sometimes the slot for plugging board is bad In this case please try o
19. NE2000 Ad Lussier 3 2 Intellio C320Turbo PCI User s Manual WWW moxa pro Software Installation 5 Select MOXA Intellio Family Multiport Board in the Select OEM Option dialog box and click OK to enter the MOXA Configuration Panel dialog box to start the installation 1 MOXA Configuration Panel 6 In the MOXA Configuration Panel dialog box click Add to enter Property dialog box to add the Intellio C320Turbo PCI board Select the C320Turbo PCT in the Board Type field and choose the appropriate one 8 16 24 or 32 ports in the Total Ports field which should match the number of ports that are physically connected Intellio C320Turbo PCI User s Manual 3 3 www ipc2u ru www moxa pro 7 In the Property dialog box click Port Setting to enter the Individual Port Setting dialog box to change the port COM number mappings Individual Port Setting xi Board Type 320TurhoPC B ports Port na Number COM Number cows V Auto Enumerating COM number Advanced Settings You have to set all the ports of the board with the desired COM number which should not conflict with other COM number in use In this Individual Port Setting dialog box you may have two ways to map the physical ports to COM numbers depending on the check box Auto Enumerating COM number Sequential Port Mapp
20. Reset to reset the driver and board for the latest configuration to take effect For more details see later section Administration Utility mxadm 057 Up to now you have already completed the whole installation and the Intellio C320Turbo PCI board is ready to work Please double check if all the Intellio C320Turbo PCI components Control Board link cable and external modules are connected and fastened tightly to make sure that the system and the driver starts successfully Intellio C320Turbo PCI User s Manual 3 25 www ipc2u ru www moxa pro ES Now you can run any ready made applications such as getty terminal or PPP SLIP You can also start to develop applications with Standard UNIX system calls as well as MOXA extended UNIX Ioctl Commands See Serial Programming Tools chapter 3 26 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro Software Installation MOXA TTY Device Naming Convention If the Intellio C320Turbo PCI is successfully configured there will be two tty devices created for each port at dev directory one is non MODEM tty e g ttyall and the other is MODEM tty e g ttyA11 The two devices are actually accessing the same physical port except that the MODEM tty has to check the ON status of DCD signal to be able to open device and closing device automatically as DCD signal is OFF The convention of the MOXA tty device name is dev tty a d 1 4 1 8 where if continuous 8 port
21. Tx throughputs per second are also reported in interval basis e g the last 5 seconds and in average basis since the time the monitoring is started You can reset all ports count by lt HOME gt key lt gt lt gt plus minus keys to change the displaying time interval HOXA Hultiport Board Administration Utility Time 90 00 46 Board 1 Type c320 Turbo PCI Interval 3 sec Rx Tx Device Char Count Throughput BPS Char Count Throughput BPS name bytes Interval Average bytes Interval Average ttuali zni11i ttual87R18 PgUp PgDn Hore Ports Home Heset Enter Port Status Intellio C320Turbo PCI User s Manual 4 11 www ipc2u ru www moxa pro Press Enter on the port that the cursor stays to view the port s communication parameters signal status and input output queue HOXA Hultiport Board Administration Utility Time 00 01 25 Board 1 Type C320 Turbo PCI Interval 3 sec lt gt mq Device Char Cou rt Status Throughput BPS Interval Average name bytes Device Hame ttya11 A11 ttya11 A11 Baud Rate 110 ttya12 A12 Parit None ttya13 A13 Data Bits 8 ttya14 A14 Stop Bits 1 ttya15 A15 CTS ttya16 A16 DSR ttyal7 Al7 DCD 18 7818 Input Queue 6251 Output Queue PgUp PgDn Hore Port Enter Port Status Terminal Emulator This utility provides data sending and receiving ability of all tty ports especially for MOXA ports It is quite useful for testing simpl
22. near the receiving side See below C32061T 65T Remote site 3 TxD B f RxD B 16 TxD A RxD A 2 RxD B TxD B 14 RxD A TxD A 5 RTS B z CTS B 13 RTS A CTS A 4 CTS B 19 CTS A RTS A Note 1 stands for termination resistor near the receiving side 2 The suggested termination resistor for AWG 26 cable is 100 ohm 3 The suggested termination resistor for phone cable is 600 ohm Intellio C320Turbo PCI User s Manual 5 9 www ipc2u ru www moxa pro www ipc2u ru RS 232 Cable Wiring for C32080T 81T 82T 83T amp CN20040 For Basic Extensive Modules only RS 232 interface with RJ 45 female connector is supported A 1 5 meter male RJ 45 to male DB25 RS 232 testing cable CN20040 is provided with shipment of the Basic Module The following RS 232 Basic Modules are designed for Intellio C320Turbo PCI C32080T Basic Module providing 8 female RS 232 ports C32081T Basic Module providing 16 female RS 232 ports The following RS 232 Extensive Modules are designed for Intellio C320Turbo PCI C32082T Extensive Module providing 8 female RS 232 ports C32083T Extensive Module providing 16 female RS 232 ports C32080T 81T 82T 83T RJ 45 Jack Pin Signals DCD DSR RTS GND TxD RxD GND CTS DTR RJ45 JACK 5 10 Intellio 20 User s Manual www moxa pro Connection Option and Cable Wi
23. queued in the buffer ioctl moxa_fd MIBUFED amp count Intellio C320Turbo PCI User s Manual 4 5 www moxa pro Syntax for UNIX SVR4 include lt sys stropts h gt include lt sys sysmacros h gt define MIBUFED 0x401 struct strioctl i0c int count number of bytes queued in the buffer ioc ic_cmd MIBUFED ioc ic_timout 0 ioc ic_len sizeof int ioc ic_dp char amp count ioctl moxa_fd I STR amp ioc Note Due to the characteristics of STREAMS driver the returned count of bytes buffered only reflect the data buffered on MOXA board not including the data buffered in STREAMS queue In this case the count is for reference only For example returned count may always be zero but there still are data buffered in STREAMS queue 2 MOBUFED This function let you know the byte count queued in output buffer when this function is issued Syntax for SCO UNIX XENIX define MOBUFED 0x402 int count number of bytes gueued in the output buffer ioctl moxa fd MOBUFED count Syntax for UNIX SVR4 include lt sys stropts h gt include lt sys sysmacros h gt define MOBUFED 0x402 struct strioctl ioc int count number of bytes queued in the output buffer ioc ic cmd MOBUFED ioc ic_timout 0 ioc ic_len sizeof int ioc ic_dp char amp count ioctl moxa_fd I STR amp ioc Note See MIBUFED for influence of STREAMS driver 4 6 Intellio C320Turbo PCI User s Manual
24. use this library to develop applications with programming languages like Visual C Visual Basic Borland C Borland Delphi UNIX C etc Utilities such as monitor terminal emulator and diagnostics are included for debugging or monitoring the communication status or for terminal emulation or file transferring Easy Installation No matter hardware or software installation are made as easy as possible Follow the installation guide to install and configure the hardware and the driver Then you can start to use Intellio C320Turbo PCI to transmit receive data to from the connected devices such as terminals modems and printers with ready made or self written application programs Broad Applications The Intellio C320Tu xbo PCI is suitable for many applications Here are a few Internet Intranet Connection Remote Access Application Multi user Application Industrial Automation Office Automation Telecommunication PC based vending Machine or Kiosk System Point of Sale POS System Features The following is a summary of all the outstanding features of Intellio C320 Turbo PCI High speed serial communication Up to 460 8 Kbps Low host CPU s overhead Dual RISC processor architecture Reliability On chip hardware flow control guarantees no data loss Modular expandability Easy to add ports for a single PC slot Supports full communication status display for each port Long range extensibility Easy for long distanc
25. www ipc2u ru Hardware Installation Without power adapter for normal condition In most cases you need not a power adapter A Set the CPU Module power switch to the OFF position This is absolutely necessary when installing or removing the cable the CPU Module or the UART Module s Power should not be switched on until you installed all components B Plug the DB25 male end of the shipped 2 meter 25 signal pin cable into the connector on the rear panel of the Intellio C320Turbo PCI Control Board Refer to the chapter 5 for the cable pinout details CMO cm 1 1 2 3 3 4 4 m d E TTT 5 5 D Lu Y Frye 6 6 o 25 signal pin Cable 1 1 00 5 C320 TurboPCI 8 8 L DII 7 2 UART Module UART Module CPU Module C Plug the other DB25 female end into the CPU Module s DB25 connector With power adapter for range extension external power condition In case of range extension or external power requirement you need a power adapter A Set the CPU Module power switch to the OFF position This is absolutely necessary when installing or removing the cable the CPU Module or the UART Module s Power should not be switched on until you installed all components Intellio C320Turbo PCI User s Ma
26. www ipc2u ru Intellio C320Turbo PCI User s Manual 6 3 www moxa pro 5 Upon system startup or driver initialization the Number of ports mismatch message appears Hardware Causes and Solutions The total number of ports installed is less than that of configured a Shut off the system and check all modules and their connections Make sure that all the module s is are fastened properly b Run the board configuration program to check the board configuration For Intellio C320Turbo PCL connect the CPU Basic Module with proper number of UART Extensive Module s as configured in configuration program c If all the possible methods fail one of the module s might be defective Please check the module s one at a time in the system to find out the defective one 6 4 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Windows NT This section is specific for troubleshooting under Windows NT For general problems and solutions please see the previous section General Troubleshooting 1 After system starts error message MOXA C320Turbo PCI Multiport Board 1 addr XXX CPU Basic Module not found appears in Event Log Shutdown the system first and refer to the problem 3 for solutions in the previous section General Troubleshooting After system starts error message MOXA C320Turbo PCI Multiport Board 1 addr XXX number of UART Modules mismatch appears in Ev
27. 320Turbo PCI initialization EO CPU Basic Module ROM error El CPU Basic Module RAM error E2 No UART Module present E4 The power to the CPU Basic Module has been switched off and on swiftly or some Module is missing during the power off time E5 The connection between Modules is loose or broken Al CPU Basic Module execution failure A2 CPU Basic Module can not communicate with Control Board 10 The first UART Module initialization failure 20 The second UART Module initialization failure 30 The third UART Module initialization failure 40 The forth UART Module initialization failure Hardware Causes and Solutions If the error message persists after check return the unit for repair As E0 EI or A1 occurs usually you have to turn off and on the CPU Module If problem persists the CPU Module might be defective As E2 occurs turn off the CPU Module firmly connect the UART Modules and turn the power back on As E4 occurs usually you have to turn off the CPU Basic Module then turn on at least time interval 3 seconds Or check if the total number of ports or modules is correct or not As E5 occurs it may indicates that the cables between modules should be fastened carefully As A occurs check the link between CPU Module and Control Board is fastened carefully As 10 20 30 or 40 occurs make sure the connection between modules 15 proper
28. 320Turbo PCI User s Manual 6 9 www moxa pro 6 10 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Appendix Technical Reference Specifications System 5 5 gt 5 D Up to 32 serial ports per Control Board Up to 4 Control Boards per PC system for a total of 128 ports Supports device drivers for most popular operating systems See the driver support list below C320Turbo PCI Windows NT Windows 95 98 SCO UNIX OpenServer UNIX SVR4 2 XENIX Linux2 0 x 2 2 x NSS SS Vv Driver supported by Moxa and shipped with product R By request Note Download the newest drivers from the MOXA FTP service Control Board 5 5 5 5 57 MHz TMS320BC52 processor 512 KB dual ported RAM maps to 16K Bytes system RAM Base addresses from 1M to 4G Selectable IRQ 2 or 9 3 4 5 7 10 11 12 or 15 Half size board ASIC and SMT design CPU Basic Module can be located up to 100 m 328 ft away from the host computer O 100 m p Module C320 Turbo PCI Intellio C320Turbo PCI 1 www moxa pro CPU Module and UART Module for Desktop Option CPU Module for Desktop option 40 MHz TMS320C32 processor 16 KB ROM and 32 K Words RAM Diagnostic LEDs show full status of each serial port including TxD RxD DTR DSR RTS CTS DCD Optional power adapter for use when the distance between
29. C320 Turbo PCI User s Manual Fourth Edition July 2008 www moxa com product MOXA 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited www ipc2u ru WWW moxa pro C320 Turbo PCI User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks MOXA is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such e
30. Checking Board Initialization Status When the system starts up and enters into the multiuser mode you should see the board initialization status report which is same as one of the messages described in the Board Reset part of previous section Setting MOXA Ports to Terminal Following procedure is how to set the MOXA port to the Terminal for login purpose taking ttyall as an example SCO UNIX OpenServer Open Desktop XENIX enable dev ttyal 1 UNIX SVR4 2 and UnixWare 1 Edit e g use vi editor the file etc inittab 2 Modify the tty entry from mal1 23 off etc getty ttyall 9600 to mal 1 23 respawn etc getty ttyal 1 9600 3 initq Or refer to your UNIX system manuals for how to activate a tty port 3 34 Intellio C320Turbo PCI User s Manual www moxa pro www ipc2u ru 4 Serial Programming Tools Moxa supports powerful but easy serial programming library and utilities under Windows NT Windows 95 98 and UNIX You will greatly save the developing time with the MOXA Serial Programming Tools The following sections details the installation the library and the utilities under various O S platforms Windows NT and Windows 95 98 PComm the professional serial comm tool for PC is a software package under Windows NT and Windows 95 98 which consists of powerful serial communication library for easy programming in most popular languages useful utilities such as diagnostic monitor and terminal emulator illust
31. Control Board and CPU Module is longer than 2 meters In this case a 10 signal pin DB25 to DB25 cable must be used between Control Board and CPU Module Power switch FCC Class A CPU Module Front View To UART Modde To Control Board S 2 Module Side View UART Module for Desktop option 8 RS 232 RS 422 serial ports TI550C UART chip with 32 bytes FIFO Tx Rx and on chip hardware flow control Each UART chip drives one serial port Max 460 8 Kbps Up to 4 at least one modules can be connected to one Control Board RS 232 DB25 female male connectors TxD RxD RTS CTS DTR DSR DCD GND Full modem control signals RS 422 DB25 female connectors TxD RxD CTS RTS GND Fixing Kit with 2 metal plates and 4 screws FCC Class A 2 Intellio C320Turbo PCI www ipc2u ru www moxa pro Technical Reference 1 2 3 4 5 6 7 8 7 UART Module Basic Module and Extensive Module for Rackmount Option Basic Module for Rackmount option 8 or 16 serial ports 40MHz TMS320C32 processor 16KB ROM and 32K Words RAM Diagnostics LEDs show full status of each serial port including TxD RxD DTR DSR RTS CTS DCD 16550C UART chip with 32 bytes FIFO Tx Rx and on chip hardware flow control Each UART chi
32. GND Intellio C320Turbo PCI User s Manual 5 13 www ipc2u ru www moxa pro C32020T Link Cable There are two different types of link cables 25 signal pin link cable and 10 signal pin link cable The former is used when there is no external power applied to the external module CPU Basic Module The latter is used when the external power is applied to the external module CPU Basic Module if you have chosen to use Long Rang Extension Kit 25 signal pin Link Cable standard The factory supplied 2 meter link cable the one with 25 signal pins is used only when you are NOT using the external power adapter Pin assignments are given below for this 25 pin link cable Warning Do not use the factory supplied 2 meter link cable with 25 signal pins and the external power adapter at the same time otherwise the Control Board or CPU Basic Module may be seriously damaged Pin No Signal Pin No Signal 1 GND 14 CLK 2 DX 15 FSX 3 DR 16 FSR 4 GND 17 GND GND 18 GND 6 GND 19 GND 7 12V 20 12V 8 5V 21 5V 9 5V 22 5V 10 5V 23 5V 11 CLK 24 FSX 12 FSR 25 DR 13 DX 5 14 Intellio C320Turbo PCl User s Manual www ipc2u ru www moxa pro Connection Option and Cable Wiring 10 signal pin Link Cable for long range extension only If the external power adapter is applied to the CPU Basic Module you will need to use the 10 pin cable accompanying with the Long Range Extension Kit The Control Board to CPU Basic
33. IRQ setting and make sure IRQ is available 7 Error message C320twin cod file not found appears UNIX Error message C320twin cod file length is wrong appears Error message C320twin cod file data content error appears It means something is wrong with driver installation or the file has been deleted accidentally or corrupted somehow To recover simply reinstall the driver This section is specific for troubleshooting under UNIX For general problems and solutions please see the previous General Troubleshooting section 1 3 During system reboots error message WARNING C320Turbo PCI XX000 BusNo X DevNo X not found appears The possible cause is memory conflict or defective board Please shutdown the system first and then refer to the problem 1 for solutions in the previous General Troubleshooting section During system reboots error message ERROR C320Turbo PCI XX000 BusNo X DevNo X download failed appears The possible cause is memory conflict or defective board Please shutdown the system first and then refer to the problem 1 for solutions in the previous General Troubleshooting section MOXA port responds too slowly or abnormal key operation The applications are not compatible with the Intellio C320Turbo PCI On board line discipline The only way to work it around is to set On board line discipline feature to Disable in Board sub menu of Advanced configur
34. RJ45 to male DB25 RS 232 testing cable CN20040 comes with the Basic Module and is provided for testing 087 4 7 means either line 4 or line 7 can be used for GND 5 12 Intellio C320Turbo PCI User s Manual WWW moxa pro Connection Option and Cable Wiring Type 3 Connecting Basic Extensive Module to a DTE device with 3 pin wiring If the Hardware flow control feature is set to you must loop back or short the RTS with CTS and DSR with DTR DCD on MOXA site indicated in dash lines of the following diagrams If the Hardware flow control feature is set to OFF you could just leave RTS CTS DSR DTR DCD open ignoring the connection indicated in dash lines C3208xT EI K RJ45 Plug Pin 1 port Serial Printer Terminal or any DTE Device A C3208xT i DTE Device RJ45 Jack Cable Wiring i DB25 Male Connector i Connector TxD 5 3 i RxD RxD 6 2 TxD GND 4 7 7 GND RTS 3 5 CTS CTS 8 4 RTS DTR Qr ses 6 DSR DSR 2 20 DTR DCD 1 8 i DCD US 4 7 means either line 4 or line 7 can be used for GND C3208xT i PC COM port Serial Printer Al i Terminal or any DTE Device K RJ45 Plug Pin 1 C3208xT DTE Device RJ45 Jack Cable Wiring DB9 Male Connector i Connector TxD 5 2 RxD RxD 6 3 TxD GND 4 7 5 GND CTS d 8 E 7 RTS DTR 9 6 DSR DSR 2 4 DTR DCD 1 1 DCD US 4 7 means either line 4 or line 7 can be used for
35. Step 8 Step 9 Hardware Installation Connect the first UART Module to the CPU Module Connect the second UART Module to the first one if necessary and so on Metal Plate Screws T 1 imp f v ET To Control Board 6 UART Module UART Module CPU Module IX For better fixation of modules Fixing Kit is available and see the bottom view of modules below to install After making sure that each component has been correctly installed you are recommended to power on the CPU Module first and then power on the PC system secondly 08 Now the installation of the external CPU UART modules is complete Continue to install the software driver explained in the chapter 3 Installing the Basic and Extensive Modules Rackmount Step 7 Connect the Intellio C320Turbo PCI Control Board to the Basic Module with the shipped DB25 to DB25 cable as shown in the following picture If range extension or external power is required please use 10 signal pin cable coming with long range extension kit instead Thus there are two types installation without power adapter and with power adapter which are described as follows Intellio C320Turbo PCI User s Manual 2 5 www moxa pro www ipc2u ru Without power adapter for normal condition In most cases you need not a power adapter Extensive Modde 1 N ZEN ak a7
36. act Size The Intellio C320Turbo PCI is also equipped with MOXA custom designed ASIC chip which replaces lots of conventional IC and hence reduces the board to half size increases the operation performance and lowers the failure rate of the board Distance Extensible Normally a standard 2 meter DB25 to DB25 cable with 25 signal pins links the Control Board to the external module However for the purpose of extending the distance between Control Board and external modules to above 2 m and up to 100 m 328 ft or improving power insufficiency problem of the PC host external power and the cable specially fabricated with only 10 signal pins should be used as illustrated in chapter 2 and chapter 5 Versatile Connection Options There are two connection options Desktop and Rackmount for the external modules to meet various connection requirements For Desktop option CPU Module and UART Modules are provided For Rackmount option Basic Module and Extensive Modules are provided with rack mount capability Besides you may choose flexibly from modules with DB25 RJ45 male female or RS 232 RS 422 1 2 Intellio C320Turbo PCl User s Manual www moxa pro www ipc2u ru Introduction UART UART CPU M odule M odule M odule 5 Cl E C N 5 4 5 sedi dos Ca 6 C 6 5 s C320 Turbo PCI SEN Tw Pal Da M DB25 to DB25 Cable
37. arameters of getty entries in system Intellio C320Turbo PCI User s Manual 3 29 Software Installation www moxa pro www ipc2u ru file etc inittab which could also be manually modified by system administrator Its value comes from the UNIX system getty default file i e etc gettydefs Modify this field to suit your need In some cases you may need to modify the getty default file as well For example in some UNIXs the 9600 symbol indicated 8 data bit no parity while in others it may stand for 7 data bit even parity So please examine the getty default file carefully and make sure the terminal settings is the same Otherwise garbled data will be inevitable Advanced Configuration This utility is to configure advanced settings for the driver excluding basic settings described in the previous Basic Configuration Similarly in the Board Settings dialog box board reset described later is available for the latest configuration to take effect without kernel rebuilding and system reboot 1 In the Advanced Board Configuration dialog box you can press Enter in each field to select the desired option The fields are detailed as follows HOKA Hultiport Board Administration Utility Advanced Configuration OnBoard LineDiscipline Baudrate Happing On Board Line Discipline Advanced feature is set to Enable by default which means all the tty line discip
38. arts error message MOXA C320Turbo Multiport Board 1 addr XXX CPU Basic module download failure appears in Event Log Shutdown the system first and refer to the problem 3 for solutions in the previous section General Troubleshooting 6 Windows NT system panic blue screen The possible reason is IRQ conflict with other ISA Bus adapters like LAN and SCSI board RAID controller or system BIOS 7 Error message C320tnt cod file not found appears Error message C320tnt cod file length is wrong appears Error message C320tnt cod file data content error appears It means something is wrong with driver installation or the file has been deleted accidentally or corrupted somehow To recover simply reinstall the driver 6 6 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Troubleshooting Windows 95 98 This section is specific for troubleshooting under Windows 95 98 For general problems and solutions please see the previous section General Troubleshooting 1 Error message MOXA C320Turbo PCI BusNo xx DevNo xx at base memory XXX download failure appears Shutdown the system first and refer to the problem 3 for solutions in the previous section General Troubleshooting Error message C320Turbo PCI BusNo xx DevNo xx at base memory XXX number of UART Modules mismatch appears Make sure that all the module s is are fasten
39. ation the UNIX section of the Software Installation chapter 6 8 Intellio C320Turbo PCI User s Manual www moxa pro www ipc2u ru Troubleshooting 4 When respawning quite a few number of tty ports the following error 5 messages appear Time out table overflow File table overflow Region table overflow The above error messages imply that the system resources are exhausted You should tune the kernel parameters to a larger value and rebuild the kernel to be able to accommodate the new configuration Refer to UNIX system manual about how to tune the parameters and rebuild kernel Time out table overflow NCALL parameter too small File table overflow NFILE or NINODE parameter too small Region table overflow NREGION or NPROC parameter too small The newly rebuilt kernel could not boot The Intellio C320Turbo PCI driver might not be built into the new kernel correctly a Please use the last good kernel backup to boot again The kernel backup in SCO UNIX is unix moxa while in UNIX SVR4 2 stand unix moxa b Then remove the Intellio C320Turbo PCI driver Refer to UNIX section of Software Installation chapter for driver removal c Re install the Intellio C320Turbo PCI driver once more When using MOXA port for PPP SLIP connection what should the On Board Line Discipline feature be set to Set to Disable Otherwise the PPP SLIP connection will fail Intellio C
40. de define MLOWATER struct strioctl int lowater lt sys stropts h gt lt sys sysmacros h gt 0x405 ioc low water value of output buffer default 512 bytes ioc ic cmd MLOWATER ioc ic timout 0 ioc ic len sizeof int ioc ic char amp lowater ioctl moxa fd I STR amp ioc 6 MSTATUS This function is used to know the RS 232 line status CTS DSR DCD Syntax for SCO UNIX XENIX define MSTATUS int status 0x407 status RS 232 line status bit0 CTS 1 on 0 off bit DSR 1 on O off bit2 DCD 1 on 0 off ioctl moxa fd MSTATUS amp status Syntax for UNIX SVR4 define MSTATUS include include struct strioctl int status ioc ic_cmd MSTATUS ioc ic_timout 0 ioc ic_len sizeof int 0x407 lt sys stropts h gt lt sys sysmacros h gt ioc status RS 232 line status bit0 CTS 1 on O off 611 DSR 1 on O off bit2 DCD 1 on 0 off ioc ic dp char amp status ioctl moxa_fd I STR amp ioc Intellio C320Turbo PCI User s Manual 4 9 www moxa pro 7 MHWFLOW This function is used to enable disable hardware flow control The first open function of a port will set the hardware flow control bits on or off depending on the RTS CTS Hardware Flow Control configuration in mxadm However you might want to control the DTR or RTS signal thus the RTS flow control bit should be
41. e application for example sending AT command to a modem connected to the port or used as a terminal for login purpose Note that this is only a dumb terminal emulation without handling full screen operation Besides data scope function with pattern file transfer is provided Dumb Terminal Emulation Terminal Emulator Menu Advance Transfer Modes Enter Select Esc Exi 4 12 Intellio C320Turbo PCl User s Manual www ipc2u ru www moxa pro Serial Programming Tools 1 Select and Press Enter on item Communication Setup to setup up all the communication parameters for connection Dumb Terminal Emulation Port Setup Device Name fdev ttyall Baud Rate 9600 Parity Hone Data Bits 5 8 8 Stop Bits 1 2 1 Ho Local Echo Ho Send Enter as CR LF CR Enter Select Esc Exit 2 Select and enter Terminal to enter terminal emulation Or select and enter Advanced Transfer Modes to perform pattern or file transfer with protocols such as ZModem Dumb Terminal Emulation Ctri H menu Advanced Transfer Modes Send Pattern Send le Enter Select Esc Intellio C320Turbo PCl User s Manual 4 13 www ipc2u ru www moxa pro 4 14 Intellio C320Turbo PCl User s Manual www ipc2u ru www moxa pro Connection Option and Cable Wiring In data communications the term DTE is Data Terminal Equipment like terminal or PC COM1 2 The term DCE is Data Communication Equipment like modem Plea
42. e cable layout h S o 4 4 1 4 Intellio C320Turbo PCl User s Manual www ipc2u ru www moxa pro Introduction Rack mountable Industrial standard 19 rack Supports most popular OS Windows NT Windows 95 98 UNIX Linux Friendly user interface for configuration and utilities Powerful but easy serial programming library and illustrative examples h Ye Check List Upon unpacking Intellio C320Turbo PCI package you should find the following items One Intellio C320Turbo PCI Control Board One CPU Module or Basic Module One 2 meter DB25 to DB25 cable for connecting Control Board and CPU Basic Module This item may not be needed if long range extension e kit is purchased For Desktop option at least one and up to four 8 port RS 232 RS 422 female male UART Module s For Rackmount option up to 32 ports of combination of 8 port or 16 port RS 232 Basic Extensive Module s For Rackmount option DB 37 to DB 37 cable s for connecting Basic Extensive Modules if Extensive Module is used For Rackmount option one 1 5 meter RJ 45 to male DB25 RS 232 cable for testing Device driver diskettes Windows NT and Windows 95 98 Version 4 9 or above X 1 PComm Lite Version 2 2 or above X 1 UNIX Version 4 10 or above X 1 This Intellio C320Turbo PCI User s Manual Fixing Kit for Desktop option Or Rack Mount Kit for Rackmount option lt 4 Th
43. e following item may be included if long range extension is needed Long range extension kit A power adapter for CPU Basic Module 90 240V AC auto select ADB25 to DB25 cable which contains only 10 signal pins for connecting Control Board and CPU Basic Module V e Intellio C320Turbo PCI User s Manual 1 5 www ipc2u ru www moxa pro Installation Guide This section gives a brief summary of how to install the Intellio C320Turbo PCI under each supported operating system Installation is simple and involves the following stages Check the PCI BIOS settings Install the Intellio C320Turbo PCI board See chapter 2 and the connection option cable module Install the software from the diskette See respective O S Section Configure the driver for the board and ports in chapter 3 Connect the devices with the cable See chapter 5 for cable wiring Y Restart the system See chapter 3 Software Check the driver initialization status Installation If the system restarts successfully you may develop your applications or See chapter 4 Serial execute the desired applications Programming Tools 1 6 Intellio C320Turbo PCl User s Manual www ipc2u ru www moxa pro 2 Hardware Installation The installation of Intellio C320Turbo PCI consists of hardware installation and software installation For software installation please refer to the respective section of operating systems in the next chapter Hardware in
44. ed properly Or click on the Taskbar Start button Programs menu MOXA Utilities menu MOXA Configuration Panel icon and connect the CPU Module with proper number of UART Module s as configured Error message MOXA C320Turbo PCI BusNo xx DevNo xx at base memory XXX ports number mismatch appears Make sure that all the Module s is are fastened properly and the ports installed are the same as configured Or click on the Taskbar Start button Programs menu MOXA Utilities menu and MOXA Configuration Panel icon and connect the Basic Module with proper number of Extensive Module s as configured Error message MOXA C320Turbo PCI BusNo xx DevNo xx at base memory XXX CPU Basic Module not found appears Shutdown the system first and refer to the problem 3 for solutions in the previous section General Troubleshooting Error message MOXA C320Turbo PCI BusNo xx DevNo xx at base memory XXX CPU Basic Module download failure appears Shutdown the system first and refer to the problem 3 for solutions in the previous section General Troubleshooting Intellio C320Turbo PCI Users Manual 6 7 www moxa pro www ipc2u ru 6 Error message C320Turbo PCI BusNo xx DevNo xx at base memory XXX interrupt failure appears This indicates MOXA board is found but the IRQ is conflicting with other adapter Make sure there is no conflict with other adapter s IRQ Check the PCI BIOS
45. ed the driver and want to re configure the Intellio C320Turbo PCI board under Windows 95 98 the following is the procedure for you 1 Click on the Taskbar Start button select the Programs menu and the MOXA Utilities menu and the MOXA Configuration Panel icon MOXA Configuration Panel E4000000 11 1 1 COM3 COM10 The Add button and the Remove button are not applicable in PCI case A new C320Turbo PCI board will be automatically found as new hardware and added during the Windows 95 98 startup To remove a board simply unplug the undesired C320Turbo PCI board physically from the system 2 Click Property to enter Property dialog box to re configure the selected board with the desired Total Ports and COM Number Choose the appropriate one 8 16 24 or 32 ports in the Total Ports field which should match the number of ports that will be physically connected Intellio C320Turbo PCI User s Manual 3 19 www ipc2u ru www moxa pro 3 In the Property dialog you may click on the Port Setting button to enter the Individual Port Setting dialog box to change the port COM number mappings Individual Port Setting x Board Type C320Turbo PCI 8 ports Port no COM Number SoMNumer Hl IV Auto Enumerating COM number Advanced Settings cen In the Individual Port Setting dialog box you may have two ways to map the physical
46. ent Log Make sure that all the modules are fastened properly Or open Control Panel select the Network icon Adapters tab and select MOXA Intellio C320Turbo Series Adapter item in the Installed Adapter Cards and click on the Properties button to start the MOXA Configuration Panel dialog box and make sure to connect the CPU Module with proper number of UART Module s as configured After system starts error message MOXA C320Turbo PCI Multiport Board 1 addr XXX number of ports mismatch appears in Event Log Make sure that all the module s is are fastened properly and the ports installed are the same as configured Or open Control Panel select Network icon then Adapters tab select Intellio C320Turbo Series Adapter item in the Installed Adapter Cards and click on the Properties button to start the MOXA Configuration Panel dialog box and make sure to connect the CPU Module with proper number of UART Module s as configured After system starts error message MOXA C320Turbo PCI Multiport Board 1 addr XXX IRQ test failure appears in Event Log This indicates MOXA board is found but the IRQ is conflicting with other adapter Please make sure there is no conflict with other adapter s IRQ Check the PCI BIOS IRQ setting first Make sure IRQ is available Intellio C320Turbo PCI User s Manual 6 5 Troubleshooting www moxa pro 5 After system st
47. er loading unloading driver upgrade and removal for various operating systems Windows NT Windows 95 98 and UNIX Chapter 4 Serial Programming Tools This Chapter roughly describes the programming tools for various O S platforms including PComm under Windows NT Windows 95 98 and standard UNIX system calls Chapter 5 Connection Option and Cable Wiring This Chapter describes the RS 232 422 cable wiring for the connection options Chapter 6 Troubleshooting This Chapter describes the problems and possible answers for C320Turbo PCI Appendix Specification details PCI Dual Ported RAM and UART are described www ipc2u ru www moxa pro Table of Contents LER OCIUG TIO I peer crc HI a i i a i k aa 1 1 Overview ei sa ees i ual i 1 1 POA ce iii a a i ii a m 1 4 aTe o r LS AM S a MM ey 1 5 Installation Gude NEN TEES 1 6 Hardware 2 1 Installing the Intellio C320Turbo PCI Control 2 1 Installing the External Modules aaa aaa aaa aaa aaa n 2 2 Installing the CPU and UART Modules Desktop 2 2 Installing the Basic and Extensive Modules 2 5 Operating LED Inelcalore pec t pn one EPIS i de Pe ee tented 2 8 Various VART MoGLUIGS ouch det oet bu a
48. et to On board Line Discipline Disable and Feature Terminal response option will be locked at Slow level UART FIFO This feature is set to Enable by default and is not able to change RTS CTS Hardware Flow Control This feature controls the hardware flow control feature If set to Disable default CTS signal is not needed for tty port to transfer data and RTS CTS hardware flow control function in driver is disabled On the contrary if set to Enable CTS signal is needed for tty port to transfer data and RTS CTS hardware flow control function in driver is enabled Performance Tuning The utility let you tune the driver to the desired response time for those ports with Resp Norm or Slow in Port Feature sub menu of Advanced configuration Ten response time levels 0 9 are available for tuning The idea is that the faster response time will consume more host CPU resource while slower response consume less resource If the host CPU is fast enough or a quick response is highly demanded choosing level 9 would be suitable HOXA Hultiport Board Administration Utility Board Performance Tuning Fastest Response Time Highest CPU Overhead 9 8 7 6 5 4 ES 2 1 Slowest Response Time Lowest CPU Overhead Tune Level 8 9 3 32 Intellio 20 User s Manual www moxa pro www ipc2u ru Software Installation Board Reset The board reset uti
49. firmware the CPU Module will scan for the number of UART Modules or the number of ports available The LED will show the last accessible port CPU Module The left digit shows the UART Module number and the right digit shows the last port number within a UART Module The UART Module closest to the CPU Module is of number 1 The next module is of number 2 and so on For example if 48 is displayed it means that the last accessible port is the eighth port of the fourth UART Module CPU Module Basic Module The left digit shows the number of 8 port unit that configured if continuous 8 ports are considered as an 8 port unit and the right digit shows the last port number within an 8 port unit For example if 48 is displayed it means that the last accessible port is the eighth port of the fourth 8 port unit Multiport Controller Basic Module Basic Module To see a particular port s line status you can keep pressing Module Button and Channel Port Button till the desired port is shown on LED display then look at the seven indicators TxD RxD DTR DSR RTS CTS and DCD This provides a convenient diagnostic ways for Intellio C320Turbo PCI Normally DTR and RTS Intellio 20 User s Manual 2 9 WWW moxa pro indicators will light on when local port is opened while DSR and CTS indicators will light on when remote port is opened TxD indicator will lig
50. ftware may not be able to write any further data to the output buffer because of the output buffer being full The application has to wait until the output buffer has enough space again The criteria to tell if the output buffer has enough space is that whether the output buffer reached its low water level That is the output buffer will accept further data only when the low water level is reached If the low water value is relatively small you may find that the output buffer become empty before you write another block of data this is quite possible because UNIX is time sharing multitasking environment This will result in discontinuous data transmission In a timeout sensitive application e g facsimile FAX transmission discontinuous data may falter the operation The default low water is 512 bytes You can enlarge it but better not exceed one half of the output buffer Each port s output buffer depends on the number of total ports See below Model Output buffer each port C320Turbo PCI w 8 ports 32K bytes C320Turbo PCI w 16ports 16K bytes C320Turbo PCI w 24ports 8K bytes C320Turbo PCI w 32ports 4K bytes 4 8 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Serial Programming Tools Syntax for SCO UNIX XENIX define MLOWATER int lowater 0x405 low water value of output buffer default 512 bytes ioctl moxa fd MLOWATER lowater Syntax for UNIX SVR4 include inclu
51. g two features UART FIFO Enable You can set this feature to Enable default and gain best performance for the board Disable You can set this feature to Disable to avoid from data loss when communicating with communication devices using S W flow control Transmission Mode Hi Performance Mode This feature is set to Hi Performance by default which accelerates the reaction of data writing behavior by utilizing buffering technology It lets your communication software reach maximum data throughput in large data transmission Intellio C320Turbo PCI User s Manual 3 5 www moxa pro Classical Mode It lets MOXA ports behave like generic COM ports Transmission for small data packets would be more precisely and reliable 8 Click OK in the Individual Port Setting and the Property dialog boxes to go back to the MOXA Configuration Panel dialog box Click OK to finish the configuration However if you installed more than one board click Add and repeat steps 6 and 7 to configure another board Up to four Intellio C320Turbo PCI boards can be installed in a system MOXA Configuration Panel x IRQ Bus Dev COM Number 14 O 11 COMS3 9 When the configuration is done click OK in the Network dialog box 10 Restart Windows NT system The latest configuration will not take effect unless the system restarts Network Settings Change You must shut dow
52. gether as long as the memory addresses and IRQ number resources are sufficient and available in a system The following flow chart illustrates the driver installation stages of the Intellio C320Turbo PCI board Each stage is detailed later 3 10 Intellio C320Tuxbo PCI User s Manual www moxa pro Software Installation Install the Intellio PCI board in the system See chapter Hardware Installation Start Windows 95 98 to detect the board Yes Driver installed before Y No Install the driver with the diskette See First Time Driver Installation Stage Configure the board and port See Port Configuration Stage Ports of Intellio C320 Turbo PCI board are ready to work See Board and Port Ready Stage Intellio C320Turbo PCI User s Manual 3 11 www ipc2u ru WWW moxa pro www ipc2u ru First Time Driver Installation Stage The stage presents the steps for installing the driver for the first time with the first Intellio C320Turbo PCI board The installation of Intellio C320Turbo PCI board for Windows 95 and Windows 98 differs slightly and will be described in two columns Follow the steps in the left or right column for Windows 95 or 98 respectively 1 Upon detecting the first new Intellio C320Turbo PCI board Windows 95 98 will automatically show a New hardware found message box and then display the following dialog box Click on the Next gt button Windows 95 Windows 98 Add New Hardware Wizard
53. gramming Tools Programming the MOXA Ports The system calls that apply to standard tty port also apply to MOXA port since MOXA port conforms to UNIX tty standard System calls are like open ioctl read write close etc Please refer to your UNIX Programmer s Reference manual However these system services only provide limited functions and thus may not satisfy the sophisticated programmers s need In order to fully control the hardware MOXA supports extended services through ioctl command which are 1 MIBUFED 0x401 To get byte count in input buffer 2 MOBUFED 0x402 To get byte count in output buffer 3 MTCRTS 0x403 To control RTS output signal 4 MTCDTR 0x404 To control DTR output signal 5 MLOWATER 0x405 To set output buffer low water level 6 MSTATUS 0x407 To read modem line status CTS DSR DCD 7 MHWFLOW 0x40e To enable disable the hardware flow control The next Section details all the commands Extended UNIX loctl Commands The following describes the syntax and usage of MOXA extended functions for both non SVR4 x and SVR4 x UNIX The variable moxa_fd is the returned file descriptor by open a specific MOXA port For example int moxa fd fd open dev ttyal 1 O RDWR 1 MIBUFED This function let you know how many bytes queued in input buffer when this function is issued Syntax for SCO UNIX XENIX define MIBUFED 0x401 int count number of bytes
54. ht on if local port is transmitting data and RxD indicator will light on if local port is receiving data or remote port is transmitting data DCD indicator is mostly useful to detect phone line carrier when a modem is connected to the port Mix of Various UART Modules UART Modules with various functions are produced for different requirements such as RS 232 RS 422 female male DB25 connector isolation protection or surge protection No matter what interfaces they use any two UART Modules could be mixed connected together freely depending on needs For example you may put 2 male RS 232 UART Modules and 2 female RS 422 UART Modules together for application consideration 2 10 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru 3 Software Installation In this chapter software driver installation configuration and driver update removal procedures are described for various operating systems including Windows NT Windows 95 98 and UNIX Before proceeding with software installation complete the hardware installation detailed in the previous chapter However if you need to develop applications refer to the next chapter Serial Programming Tools for more information Windows NT Windows NT supports up to 256 serial ports from COMI to COM256 To fully integrate the advanced features of Windows NT multi process and multi thread pure 32 bit Windows NT device drivers are developed for Intell
55. ic Configuration This utility is to configure basic settings for the driver 1 Inthe Basic Configuration dialog box you should first press Enter in the 3 28 Intellio C320Tuxbo PCI User s Manual www ipc2u ru WWW moxa pro www ipc2u ru Board type field to select board type C320Turbo PCI And a list of Intellio C320Turbo PCI boards found available is for you to select Normally one choice is available if there is one Intellio C320Turbo PCI board installed beforehand Hultiport Board Administration Utility Board Basic Configuration EET is 000000 Secondly select number of ports in the Ports field to match exactly the number of ports physically connected Press Enter on the desired entry of the list to select Now the selected Intellio C320Turbo PCI board is configured with BIOS assigned memory address and Bus Device numbers as shown Press Page Down to enter getty Setting sub dialog there are some noticeable fields for initialize the port for getty usage You may skip this step if you will not use getty utility HOXA Hultiport Board Administration Utilit Board Ho Device Name ttya12 A12 ttya13 A13 ttya14 A14 ttya15 A15 ttya16 A16 ttyal7 A17 ttya18 A18 PgUp PgDn Hore Ports Enter Select Es Non Modem and Modem Baud Rate This field stands for the initial baud rate symbol and hunt sequence for Non Modem Modem tty It is simply for setting p
56. ing Enable Auto Enumerating COM number Specify the COM number of the first port and subsequent ports are mapped to continuous COM numbers For instance if first port is mapped to COM10 then second port is mapped to COM11 sequentially Non sequential Port Mapping Disable Auto Enumerating COM number Specify the COM number for individual port For instance the second port can be out of sequence say COM18 while the first port is mapped to COM10 In Individual Port Setting dialog you may click on Advanced Setting button to tune the advanced features UART FIFO and Transmission Mode for each port for particular performance requirements 3 4 Intellio C320Turbo PCI User s Manual www ipc2u ru WWW moxa pro www ipc2u ru Software Installation You may skip the following settings and go directly to the next step 8 if you do not require any particular performance tuning for the e Advanced Settings Eg Board Type 320TurboPCI 8 ports Port No UART FIFO Transmission Mode 1 Enable Hi Performance 2 Enable Hi Performance 3 Enable Hi Performance 4 Enable Hi Performance 5 Enable Hi Performance 6 Enable Hi Performance 7 Enable Hi Performance 8 Enable Hi Performance Port 1 UART FIFO Transmission Mode Enable Hi Performance Disable Classical EN In the Advanced Settings dialog you may customize the driver with the followin
57. io C320Turbo PCI and other MOXA multiport boards The drivers conform to Win32 COMM API standard If you install the driver for the first time please go directly to the section Installing Driver If you already have installed the driver and want to re configure the board and port add more boards or delete boards please refer to the section Configuring Board and Port If you want to update or even remove driver please go to the section Updating Driver and section Removing Driver If you want to remove boards please simply unplug the desired boards from the system Intellio C320Turbo P Users Manual 3 1 WWW moxa pro www ipc2u ru Installing Driver Following is the procedure for installing the Intellio C320Turbo PCI driver for the first time under Windows NT 3 51 4 0 Make sure the board s has have already been plugged in the PCI slot of the PC 1 Please Login NT as Administrator 2 Open the Control Panel click on the Network icon and select the Adapters tab 3 Click on the Add button then Have Disk button in Select Network Adapter 4 Specify the exact path of the driver diskette ANWINDOWS NT Click OK Big 3Com Etherlink II Adapter also 11 16 and 1216 3Com Etherlink III ISA PCMCIA Adapter O Add ii 3Com EtherLink III PCI Bus Master Adapter 30590 89 3Com Etherlink16 EtherLink16 TP Adapter ere Cant E Hsec inte DCI 10H 00DA Adanta Novell
58. ion Installing Driver for more details Click Remove to remove the board currently selected from the configured board list Click OK to confirm the configuration changes you made Click Cancel to leave the dialog with the configuration unchanged 3 8 Intellio C320Turbo PCl User s Manual www ipc2u ru WWW moxa pro Software Installation Adding Removing Board Following is the procedure to add remove Intellio C320Turbo PCI Series boards after a first time installation Note that the presence of the board s is are required for adding boards Power off the system Plug unplug the boards in the system Power on the system Run the software configuration MOXA Configuration Panel to add remove the boards detailed in the previous Configuring the Board and Port section AU Updating Driver To update the driver for the Intellio C320Turbo PCI board simply remove the driver as described in the next section and then reinstall it as detailed in the Installing Driver section Removing Driver To remove the driver for the Intellio C320Turbo PCI board 1 Open the Control Panel click on the Network icon and select the Adapters tab 2 Select MOXA Intellio Family Adapter in the adapter list then click on the Remove button and the OK button to remove the driver 3 Restart the system to activate the new configuration Intellio C320Turbo PCI User s Manual 3 9 www ipc2u
59. l Transmission Mode Hi PerformanceMode This feature is set to Hi Performance by default which accelerates the reaction of data writing behavior by utilizing buffering technology It lets your communication software reach maximum data throughput in large data transmission Classical Mode It lets MOXA ports behave like generic COM ports Transmission for small data packets would be more precisely and reliable 3 16 Intellio C320Tuxbo PCI User s Manual www ipc2u ru WWW moxa pro www ipc2u ru Board and Port Ready Stage Software Installation Click OK for all the dialog boxes to finish the configuration and exit the MOXA Ports Installation dialog box In this last stage you will complete the driver installation Windows 95 After the port installation you can immediately use the COM ports of the Intellio C320Turbo PCI board without restarting the Windows 95 system Windows 98 After the port installation click on the Finish button Now you can immediately use those COM ports of the Intellio C320Turbo PCI board without restarting the Windows 98 system Add New Hardware Wizard gt MOXA C320 Turbo PCI Windows has finished installing the software you selected that your new hardware device requires Once the installation is finished error conditions of the board if any are displayed on the screen Otherwise everything should be fine If an error message similar to C320Turbo PCI
60. line jobs e g translating NL to CR will be done on the Intellio C320Turbo PCI board Terminal mode instead of doing them on host This will significantly reduce the host workload If it is set to Disable the tty line discipline will either be done on host Terminal mode or be not done at all Transparent mode Please refer to Feature field in the Advanced Port Settings dialog box on next page 3 30 Intellio C320Turbo PCI User s Manual www moxa pro www ipc2u ru 2 Software Installation Baud Rate Mapping This advanced feature is set to High Band by default indicating that the baud rate 50 B50 will no longer stand for 50 bps Instead B50 means 57600 bps B75 is for 115 2 Kbps B110 is for 230 4 Kbps and B134 is for 460 8 Kbps You may press F1 Help for on line details Baudrate Mapping High Band lt Label gt lt Real Baud Rate gt Default B75 115200 B110 230400 B134 460800 B150 150 B200 200 B300 300 B600 600 B1200 1200 B1800 1800 B2400 2400 B4800 4800 B9600 9600 B19280 19200 B38400 38400 Esc Exit PageUp PageDown Hore In Press PageDown to enter the Advanced Port Settings sub dialog there are some noticeable fields to initialize the ports for advanced usage You may skip this step if vou do not concern these features HOXA Hultiport Board Administration Utilit HOXA Board Advanced Port Settings Board Ho Device Name Feature Response UART FIFO RTS
61. lity eliminates the need to shut down the UNIX system for re initializing the Intellio C320Turbo PCI board with new configuration Press Enter to start board reset HOXA Hultiport Board Administration Utility Hessage 1 The HOXA Boards will be reset and data buffers 11 flush All the applications accessing these MOXA boards should be stopped by now You may restart the application after board reset completed Press ENTER to reset MOXA board or any key to abort However before the board reset is issued you must make sure that 1 All enabled ports must be disabled 2 All processes related to the Intellio C320Turbo PCI including getty or tty monitor are killed Once the board is reset the following message may show if it is successful MOXA Serial I O Board Ver x x Downloading MOXA C320Turbo PCI MemBank XX000 BusNo X DevNo X is found If one of the following message appears please see Troubleshooting chapter WARNING C320Turbo PCI XX000 BusNo X DevNo X not found Or ERROR C320Turbo PCI MemBank XX000 download failed Driver Removal If you want to remove the Intellio C320Turbo PCI device driver and return to your previous system configuration simply press Enter in this function entry and answer Y to confirm Then the system will be rebuild This may take some time If you answer N no action will be taken Intellio C320Turbo PCI User s Manual 3 33 www moxa pro www ipc2u ru
62. n and restart your computer before the new settings will take effect Do you want to restart your computer now Please double check if all the Intellio C320Turbo PCI components Control Board link cable and external cable module are connected and fastened tightly to make sure that the system and the driver start successfully later 3 6 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Software Installation 11 Once the system restarts you may check the event log issued by MOXA drive to see if the ports of the board are initialized successfully Enter the Administrative group Event Viewer and select Application Event Log to check a successful message similar to MOXA C320Turbo PCI Multiport Board 1 addr XXX O K for each configured board If an error message similar to MOXA C320Turbo PCI Multiport Board 1 addr XXX IRQ 10 test failure appears refer to the Troubleshooting chapter for solutions Once the board and driver are installed and the system restarts successfully you can start to develop applications by using PComm library See Serial Programming Tools chapter or using Microsoft Win32 API you can also execute any ready made application such as PComm utility Terminal emulator See Serial Programming Tools chapter or HyperTerminal to transmit receive data as well as Remote Access Service to provide dial up networking capability Configuri
63. ncel In the Advanced Settings dialog box you may customize the driver with the following two features UART FIFO Enable You can set this feature to Enable default and gain best performance for the board Disable You can set this feature to Disable to avoid from data loss when communicating with communication devices using S W flow control Transmission Mode Hi PerformanceMode This feature is set to Hi Performance by default which accelerates the reaction of data writing behavior by utilizing buffering technology It lets your communication software reach maximum data throughput in large data transmission Classical Mode It lets MOXA ports behave like generic COM ports Transmission for small data packets would be more precisely and reliable Intellio C320Turbo PCI User s Manual 3 21 www ipc2u ru WWW moxa pro 4 Click OK in the Individual Port Setting and the Property dialog boxes to go back to the MOXA Configuration Panel dialog box Click OK to finish the configuration 5 Restart Windows 95 98 system if you have changed any setting The latest configuration will not take effect unless the system restarts 3 22 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro www ipc2u ru Software Installation Updating driver Open the Control Panel and click on the System button and select the Device Manager tab Select the Moxa Intellio Multiport Board en
64. ng Board and Port If you already have installed the driver and want to re configure the board and port add more boards or delete boards please follow this procedure 1 Open Control Panel click Network and select the Adapters tab 2 Select MOXA Intellio Family Adapter in the Installed Adapter Cards Network mE Identification Services Protocols Adapters Bindings Network Adapters EIS 1 Novell NE2000 Adapter 10 MOXA Intellio Family Adapter 3 Realtek RTL8029 PCI Adapter a Remove Properties Update ovell 2000 Adapter Intellio C320Turbo PCI User s Manual 3 7 www moxa pro 3 Click on the Properties button to enter the MOXA Configuration Panel dialog box MOXA Configuration Panel x IRG Bus Dev Number 11 0 11 COM3 COM10 In this configuration panel you may Click Property to enter Property dialog box to configure the selected board with the correct Total Ports and COM Number Please see steps 6 to 8 in the previous section Installing Driver for more details except that the Board Type field is not supposed to be changed Click Add to add one more board that is not yet configured in the system Up to four of Intellio C320Turbo PCI boards can be installed together as long as the memory and IRQ resources are sufficient and available in a system Please see steps 6 to 8 in the previous sect
65. nual 2 3 www moxa pro B Plug the DB25 male end of the shipped 2 meter 10 signal pin cable the link cable comes with long range extension kit or the one fabricated according to the pinouts in the chapter 5 into the connector on the rear panel of the Intellio C320Turbo PCI Control Board Ci Ci 2 cH le 5 1Osigna pin lu x A a E A 4 i co 5 9 YJ 6 6 LL ELI 7 8 8 LL 7 2 UART Modue UART CPU Mode C Plug the other DB25 female end into the CPU Module s DB25 connector Do not use a 25 signal pin cable to connect the Intellio C320Turbo PCI Control Board to the CPU Module when using the power adapter as this will cause power crash One power comes from the power adapter while the other power comes from the Intellio C320Turbo PCI Control Board D Connect the power adapter to the CPU Module Keep the CPU Module s power switch in the OFF position If UART Module s is are also required keep the CPU Module s power switch in the OFF position until all necessary UART Module s is are installed E Install the power adapter to a power source either 110V or 220V AC Adjustment to the AC power specs is done automatically 2 4 Intellio 20 User s Manual www ipc2u ru www moxa pro www ipc2u ru
66. nuous COM numbers For instance if first port is mapped to COM10 then second port is mapped to COM11 sequentially Non sequential Port Mapping Disable Auto Enumerating COM number Specify the COM number for individual port For instance the second port can be out of sequence say COMIS while the first port is mapped to COMIO Intellio C320Turbo PCI User s Manual 3 15 www ipc2u ru WWW moxa pro In addition in the C320Turbo PCI Installation dialog box you may click on Advanced Settings button to tune the advanced features UART FIFO and Transmission Mode for each port for particular performance requirements Advanced Settings x Board Type icaz TurboPCI 8 ports UART FIFO Transmission Mode Enable Hi Performance 1 2 Enable Hi Performance 3 Enable Hi Performance 4 Enable Hi Performance 5 Enable Hi Performance 6 Enable Hi Performance 7 Enable Hi Performance 8 Enable Hi Performance Port 1 Enable Hi Performance C Disable UART FIFO Transmission Mode Classical wo LA In the Advanced Settings dialog box you may customize the driver with the following two features UART FIFO Enable You can set this feature to Enable default and gain best performance for the board Disable You can set this feature to Disable to avoid from data loss when communicating with communication devices using S W flow contro
67. only occupies 16 KB of memory space window from the system point of view Memory base addresses range from 1 M to 4 GB Intellio C320Turbo PCI 5 www moxa pro 16550C in UART Basic Extensive Modules The 16550C is an advanced asynchronous controller capable of on chip hardware flow control and highest speed up to 921 6 Kbps Inside UART Basic Extensive Module each 16550C chip controls one port A 6 Intellio C320Tuxbo PCI www ipc2u ru www moxa pro
68. p drives one serial port Max 460 8K bps Full modem control RS 232 interface RJ 45 connector for each serial port Optional power adapter for use when the distance between Control Board and Basic Module is longer than 2 meters In this case a 10 signal pin DB25 to DB25 cable must be used between Control Board and Basic Module Power switch Intellio C320Turbo PCI www ipc2u ru www moxa pro Basic Module Front View Multiport Controller PT Power TxD RxD DTR DSR RTS CTS DCD Basic Module Rear View P9 16 ray To next module PI LL1 1 P8 From PC DCIN ON OFF y To Control Board Extensive Module for Rackmount option 8 or 16 RS 232 serial ports 16550C UART chip with 32 bytes FIFO Tx Rx and on chip hardware flow control Each UART chip drives one serial port Max 460 8 Kbps Full modem control RS 232 interface RJ 45 connector for each serial port 4 4 Ye 4 Extensive Module Front View P9 BEHEBERBB P16 5 To next module 8 From previous module A 4 Intellio C320Turbo PCI www ipc2u ru www moxa pro www ipc2u ru PCI Technical Reference The 32 bit Intellio C320Tu xbo PCI board complies with PCI Spec 2 1 Hardware configuration for IRQ and Memory addresses is automatically assigned by PCI BIOS Hence it is a must to have the board plugged fir
69. ports to COM numbers depending on the Auto Enumerating COM number check box Sequential Port Mapping Enable Auto Enumerating COM number Specify the COM number of the first port and subsequent ports are mapped to continuous COM numbers For instance if first port is mapped to COM10 then second port is mapped to COM11 sequentially a Non sequential Port Mapping Disable Auto Enumerating COM number Specify the COM number for individual port For instance the second port can be out of sequence say COM18 while the first port is mapped to COM10 In the Individual Port Setting dialog box you may click on Advanced Settings button to tune the advanced features UART FIFO and Transmission Mode for each port for particular performance requirements Note You may skip the following settings and go directly to the next step 4 if you do not require any particular performance tuning for the driver 3 20 Intellio C320Turbo PCI User s Manual www ipc2u ru WWW moxa pro Software Installation Advanced Settings xi Board C320Turbo PCI 8 ports UART FIFO Transmission Mode 1 Enable Hi Performance 2 Enable Hi Performance 3 Enable Hi Performance 4 Enable Hi Performance 5 Enable Hi Performance 6 Enable Hi Performance 7 Enable Hi Performance 8 Enable Hi Performance Port 1 UART FIFO Transmission Mode Enable Hi Performance Disable C Classical Help Ca
70. r example under Windows NT and Windows 95 98 PComm utility Terminal emulator or Hyperterminal is good for testing COM ports Under UNIX Terminal emulator in the MOXA administration utility mxadm and stty cat or getty are existed programs for testing tty port 3 CPU Basic Module not found message appears Or CPU Basic Module can not download firmware from the Control Board Hardware Causes and Solutions a Switch off the CPU Basic Module Check that the connection cable between the CPU Basic Module and the Control Board is correct and firmly connected on both sides Switch on the CPU Basic Module then power on the Control Board system to wait until the LED display of CPU Basic Module reads Ld Sometimes it happens when the total consumption of power in the system is higher than the power adapter can provide Especially when many interface boards including MOXA board s are plugged in the system It is recommended to replace the current power adapter with higher watt one Or choose the external power option if Intellio C320Turbo PCI is used If all the possible methods fail the CPU Basic Modules might be defective Please check the module s one at a time in the system to find out the defective one 6 2 Intellio C320Turbo PCI User s Manual www moxa pro Troubleshooting 4 Error messages appear on CPU Basic Module LED display Any of the following messages means failure of the Intellio C
71. rative example programs and comprehensive on line documents The serial communication library is useful for developing a system for data communication remote access data acquisition or industrial control in the Windows NT and Windows 95 98 environment which offers an easier solution compared with the more complex Windows Win32 COMM API Installation To install PComm please run Setup exe in the diskette Note that PComm diagnostic and monitor utilities are for MOXA boards only MOXA Windows NT or Windows 95 98 device driver as well as MOXA board are required The driver are installed separately and detailed in Software Installation chapter Intellio C320Turbo PCI User s Manual 4 1 www moxa pro PComm Programming Library The serial communication library is to assist you to develop programs for serial communications for any COM port complying with Microsoft Win32 API It can ease the implementation of multi process and multi thread serial communication programs and hence greatly reduce the developing time For complete library function description and example programs for Visual C Visual Basic and Delphi please see help file and example programs in PComm directory for more details Utilities The followings are short descriptions of each utility For details please see on line help in the diskette Diagnostic for MOXA boards only A convenient diagnostic program provides internal and external testing such as IRQ
72. res described below make Intellio C320Turbo PCI the best choice for medium to large scale data communication systems from 8 to 128 serial ports Intellio The Intelligent 8 32 Port Serial I O Solution The Intellio C320Turbo PCI is an intelligent dual CPU high speed expandable multi serial communication controller which aims to gain higher speed achieve better performance and lessen the load of the host system Port Expandable The Intellio C320Turbo PCI is composed of a Control Board a DB25 to DB25 cable some external modules The Intellio C320Turbo PCI supports expandability from 8 to 32 ports for a single PC slot Up to 128 ports could be used in the PC with four Intellio C320Turbo PCI installed PCI Solution The board complies with PCI Spec 2 1 and has neither switch nor jumper Hardware configuration for the IRQ number and memory addresses is automatically assigned by PCI BIOS Hence it is a must to have the board plugged first before installing software driver For more PCI information see appendix Intellio C320Turbo P User s Manual 1 1 www moxa pro www ipc2u ru Low Host Processor Overhead The Intellio C320Turbo PCI is equipped with two high performance processors TMS320 on both the Control Board and the CPU Basic Module and 512KB on board memory to relieve the host s CPU workload of all data and I O handling tasks The memory buffer holds transmitted and received data to prevent data loss ASIC Design Comp
73. ring 1 Connecting Basic Extensive Module to a DTE device CN20030 PC COM2 port Serial Printer C3208xT EI d Terminal or any DTE Device iW RU45 Plug Pin 1 A C3208xT DTE Device RJ45 Jack Cable Wiring DB25 Male Connector i Connector DCD 1 8 DCD DSR 2 20 DTR RTS 3 5 CTS GND 4 7 7 GND TxD 5 3 RxD RxD 6 2 TxD CTS 8 4 RTS DTR 9 6 DSR 0S For Rackmount option this RJ45 to female DB25 RS 232 testing cable CN20030 is available from Moxa 087 4 7 means either line 4 or line 7 can be used for GND C3208xT j a port serial printer d a terminal or any DTE device WRJ45 Plug Pin 1 i C3208xT DTE Device RJ45 Jack Cable Wiring i DB9 Male Connector Connector DCD i 1 1 DCD DSR 2 4 DTR RTS 3 8 CTS GND 4 7 5 GND TxD 5 2 RxD RxD 6 3 TxD CTS 8 7 RTS DTR 9 6 DSR 087 4 7 means either line 4 or line 7 can be used for GND Intellio C320Turbo PCI User s Manual 5 11 www ipc2u ru www moxa pro www ipc2u ru Type 2 Connecting Basic Extensive Module to a DCE device Cable CN20040 K RJ45 Plug Pin 1 C3208xT RJ45 Jack Cable Wiring Connector DCD DSR RTS GND TxD RxD CTS DTR C3208xT A Modem i or any DCE Device DCE Device DB25 Female Connector DCD DTR CTS GND RxD TxD RTS DSR 08 For Rackmount option this
74. rrors and these changes are incorporated into new editions of the publication Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 www ipc2u ru Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 www moxa pro About This Manual This manual is composed of six Chapters and one Appendix This manual is written for installer system administrator and software programmer If you are a first time installer and system administrator we recommend you to go through the whole manual except Chapter 4 If you are a software programmer you may refer to Chapter 4 Serial Programming Tools If you need cable wiring information please see Chapter 5 Connection Option Opt8x and Cable Wiring If you encounter any problem during installation please refer to Chapter 6 Troubleshooting ES n this manual C320Turbo Series refers to C320Turbo and C320Turbo PCI Chapter1 Introduction Overview and features for C320Turbo PCI are described Also check list and overall installation guide Chapter 2 Hardware Installation Hardware installation for C320Turbo PCI Chapter 3 Software Installation This Chapter details the software installation configuration driv
75. ru www moxa pro www ipc2u ru Windows 95 98 Windows 95 98 supports up to 128 serial ports from COMI to COM128 To fully integrate the advanced features of Windows 95 98 multi process and multi thread pure 32 bit Windows 95 98 virtual device port drivers VxD compliant with communication driver VCOMM are developed for Intellio C320Turbo PCI and other MOXA multiport boards The drivers conform to Win32 COMM API standard If you install the driver for the first time or you want to install more boards please go directly to the section Installing Driver If you already have installed the driver and want to re configure the board please refer to the section Configuring Board and Port If you want to update or even remove driver please go to the section Updating Driver and secton Removing Driver If you want to remove boards please simply unplug the undesired boards from the system Installing Driver If you install for the first time or you want to install more boards this section is for you You can easily plug the Intellio C320Turbo PCI board and work right away with very little installation efforts under Windows 95 98 which supports Plug and Play capability The Windows 95 98 will automatically detect the presence of the newly plugged board and prompt you to install the software driver the first time In this case you need the driver diskette Up to four Intellio C320Tu xbo PCI boards can be installed to
76. s are viewed as an 8 port unit for Intellio C320Turbo PCI Rackmount tty A B MP Port ordinal number in a UART Module 8 port unit 1 8 UART Module 8 port unit ordinal number 1 4 Board ordinal number a or A 1st MOXA board b or B 2nd MOXA board c or C 3rd MOXA board d or D 4th MOXA board Capitals indicate a MODEM port Standard tty device prefix To next module PI P8 DCIN ON OFF Intellio C320Turbo PCI User s Manual 3 27 www ipc2u ru www moxa pro dev ttyal1 dev ttyal2 dev ttyal3 dev ttyal4 dev ttyal5 Taking 8 port Intellio C320Turbo PCI as an example N devittyal6 17 BR dev ttyal8 UART Module CPU Module Administration Utility mxadm You can use the administration utility mxadm to change the Intellio C320Turbo PCI basic and advanced configuration to reset the board to tune performance and to remove the installed MOXA driver from the UNIX system which are detailed as follows For the details of the rest utilities port monitoring and terminal emulator please refer to UNIX section of Serial Programming Tools chapter MOXA Hultiport Board Administration Utility HAIN MENU Advanced configuration board Reset perFormance tuning Port monitoring Terminal emulator Driver removal Exit Bas
77. se check the precise pinouts the following pinouts are typical examples The UART modules for Desktop option provide both RS 232 and RS 422 connection options depending on the models of modules you choose The Basic Extensive modules for Rackmount option provide merely RS 232 connection options However all the modules can use together with MOXA A50 A51 to obtain RS 422 RS 485 capabilities See MOXA A50 A51 User s Manual for details RS 232 Cable Wiring for C32045T C32047T C32071T The following RS 232 UART Modules are designed for Intellio C320Turbo PCI C32045T UART Module providing 8 female RS 232 ports C32047T UART Module providing 8 male RS 232 ports C32071T UART Module providing 8 female RS 232 ports with 2000V surge protection which can protect ports from lightning There are two types of connectors female or male for RS 232 UART Modules You have to identify the type of connectors and apply the correct cable wiring Intellio C320Turbo PCI User s Manual 5 1 www ipc2u ru www moxa pro UART Module C32045T 71T DB25 Female Connector 1 ON tA amp S UART Module C32047T DB25 Male Connector OV tA 4 C2 RxD TxD CTS RTS DTR GND DCD DSR TxD RxD RTS CTS DSR GND DCD DTR 20 DSR 20 DTR 8 7 6 3 4 3 2 Type 1 Connecting UART Module to a DTE device C32045T 71T C32045T 71T DB25 Female Connector RxD TxD CTS RTS DTR DSR GND
78. st before installing software driver Unlike ISA slots different PCI slots in the same PC may have different bus numbers and device numbers with respect to PCI specifications The same PCI board will have different system configurations if switched to a different PCI slot which may be called slot sensitive or slot dependent This may also apply to PCI slots in PC of different mother board which may use different device number set For example some use 17 18 19 and 20 for identifying the respective PCI slot but some use 11 12 13 and 14 Due to the slot dependency it is necessary to re configure the software driver once the board is plugged in different PCI slots Up to four boards of Intellio C320Turbo PCI are allowed in a system When installing multiple boards please do keep in mind the order you plug the boards for distinguishing the boards installed Dual Ported RAM There is 512 KB of dual ported DRAM on the Intellio C320Turbo PCI Control Board which is used as a data buffer and memory map device for the motherboard it is called dual ported because it is accessed by both motherboard CPU and the Intellio C320Turbo PCI Control Board s on board CPU Generally speaking the memory access time is much faster than normal I O access All messages and data are transferred through this 512 KB dual ported memory The buffer area appears as normal 16 bit memory to the PC AT I O channel Every Intellio C320Turbo PCI Control Board
79. stallation is stated in this chapter The no switch no jumper Intellio C320Turbo PCI board s hardware configuration for IRQ and memory addresses is automatically assigned by PCI BIOS Hence it is a must to have the board plugged first before installing software driver After this simply install the Control Board into the PC and then connect one of the connection options Desktop or Rackmount The Intellio C320Turbo PCI hardware installation consists of Control Board installation and external module installation Make sure you have connected the Control Board with proper number of external modules Installing the Intellio C320Turbo PCI Control Board Step 1 Power off the PC Warning Make sure you switch off the system before installing any PCI board If you don t you may risk damaging your system and the board Step 2 Remove the PC s cover Step 3 Remove the slot cover bracket if present Step 4 Plug the Intellio C320Turbo PCI firmly into any free 32 bit PCI slot Step 5 Fasten the holding screw to make the Control Board fixed Intellio C320Turbo P User s Manual 2 1 www ipc2u ru www moxa pro www ipc2u ru Step 6 Replace the system cover Note Each board must occupy one unique IRQ and one unique memory address which are assigned by PCI BIOS automatically However you may select the free IRQ number manually via PC s BIOS setup for PCI slot but this method is not available for memory The possible IRQ n
80. ther slots until a good one is found c Your mother board does not have vacant IRQ for the Intellio C320Turbo PCI Please enter BIOS and make sure there are available IRQ in PCI PnP setting 2 MOXA board and driver activated but not transfer transmitting receiving data Hardware Causes and Solutions a Check if wrong cable wiring Refer to the Connection Option and Cable Wiring chapter for precise pinouts of the connector type you are using b Cable external modules or board is defective You may use other port cable Intellio C320Turbo PCI User s Manual 6 1 www moxa pro www ipc2u ru or box or board to verify In addition PComm utility Diagnostic for Windows NT and Windows 95 98 is good for testing MOXA board and port condition If the report of diagnostic shows error replace the error component Software Causes and Solutions a Intellio C320Turbo Series will check line status CTS before it sends data out if RTS CTS flow control feature is set to Enable in configuration or application program Please see the Connection Options and Cable Wiring chapter for proper wiring Check the line status of the suspected port using the diagnostic LED indicators on the mini tester Perhaps the application controlling the board is not correctly written according to the corresponding API of the operating system To verify please run existing and known good application or Moxa provided utility Fo
81. try and the Moxa C320Turbo PCT entry Click on the Property button and select the Device Driver tab and then click on the Update Driver button System Properties Moxa C320 Turbo PCI Properties D Display adapters Floppy disk controllers 9 Hard disk controllers Removing driver Open Control Panel icon and then Add Remove Programs icon and then select Install Uninstall tab Then select and open the MOXA Intellio Driver option and then enter OK to remove the driver Intellio C320Turbo PCI User s Manual 3 23 www moxa pro UNIX Installing Driver Up to four boards of combination of Intellio C320Turbo PCI and C320Turbo can be installed together as long as memory resources are sufficient and available in a system Step 1 Step 2 Step 3 Step 4 Step 5 Boot the system and login from the console as a super user root Insert the driver diskette into a 1 44MB floppy drive A or B If the driver files are obtained from the MOXA FTP service put them under the tmp moxa directory and skip to the step 5 Change to the root directory by entering the following command 1 cd Enter the following command to extract the installation script file first tar xvf dev fd0135ds18 tmp moxa mxinstall if 1 44MB A tmp moxa mxinstall Follow the instructions prompted to finish the driver installation Copyright C 199x Moxa Technologies Co Ltd All Rights Reserved
82. turned off HWFLowControlOff in order to take over the control of DTR or RTS signal via function MTCRTS or MTCDTR MTCRTS and MTCDTR can be effective only after the RTS flow control bit is turned off Syntax for SCO UNIX XENIX define MHWFLOW 0x40e define HWFlowControlOff 0x00 define CTSFlowControlBitOn 0x01 define RTSFlowControlBitOn 0x02 define HWFlowControlOn 0x03 ioctl moxa fd MHWFLOW CTSFlowControlBitOn ioctl moxa fd MHWFLOW RTSFlowControlBitOn ioctl moxa_fd MHWFLOW CTSFlowControlBitOn RTSFlowControlBitOn Syntax for UNIX SVR4 include lt sys stropts h gt include lt sys sysmacros h gt define MHWFLOW 0x40e define HWFlowControlOff 0x00 define CTSFlowControlBitOn 0x01 define RTSFlowControlBitOn 0x02 define HWFlowControlOn 0x03 struct strioctl ioc int setting setting CTSFlowControlbitOn ioc ic_cmd MHWFLOW ioc ic_timout 0 ioc ic_len sizeof int ioc ic_dp char amp setting ioctl moxa_fd I STR amp ioc 4 10 Intellio C320Turbo PCI User s Manual www ipc2u ru www moxa pro Serial Programming Tools Utilities You can use the administration utility mxadm to monitor port activity and to do terminal emulation which are details as follows Port Monitoring This utility gives you a quick view about all the MOXA ports activities You can easily learn each port s total received transmitted Rx Tx character count since the time when the monitoring is started Rx
83. umbers are 2 or 9 3 4 5 7 10 11 12 and 15 08 Now the installation of the Control Board is complete Continue to install the external modules Installing the External Modules There are two major connection options for the installation of external modules CPU and UART Modules for Desktop option or Basic and Extensive Modules for Rackmount option Normally a standard 2 meter DB25 to DB25 cable with 25 signal pins links the Control Board to the external module However to extend the distance between Control Board and external module to above 2 m and up to 100 m 328 ft or to improve power insufficiency problem of the PC host external power for the CPU Basic Modules along with a cable specially fabricated with only 10 signal pins should be used as illustrated in the next two subsections and in chapter 5 as well Otherwise power degradation which comes from longer cable or power insufficiency of PC host will cause system failure Installing the CPU and UART Modules Desktop Step 7 Connect the Intellio C320Turbo PCI Control Board to the CPU Module with the shipped DB25 to DB25 cable as shown in the following picture If range extension or external power is required please use 10 signal pin cable coming with long range extension kit instead Thus there are two types of installation without power adapter and with power adapter which are described as follows 2 2 Intellio C320Turbo PCl User s Manual WWW moxa pro

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - A`PEXi  StarTech.com 5m DVI to VGA Display Monitor Cable M/M - DVI to VGA (15 Pin)  SMS-01BT  Best practice in crime analysis  USER MANUAL - CAMBOARD Electronics  Smeg FA40X5 Instructions for Use  Traitement de l`eau de boisson dans les situations d`urgence    Istruzioni per l`uso  TWINMATE L-208 Gebrauchsanweisung Mode d`emploi  