Home
- Vacuubrand.com
Contents
1. 31 Mode Control 43 Mode selection 46 mode View 31 Mode View 40 Momentarily venting 53 N Network configuration and updates 58 Network configuration menu LAN 60 Network configuration menu WLAN O Open default view 29 38 Operating elements 31 Operation 38 P Parameter settings 48 Password 58 61 password protected 42 Personal responsibility 16 Personnel 68 Pressure reading 34 Pressure Time graph JO Product description 19 Product features 20 Q Quick navigation 32 42 57 APPENDIX R Radio button 31 Rating plate 74 RC adapter 73 Recommended web browser 21 Required CVC firmware 62 Reset 000008 12 S Safety toe bho Ga AA 7 Safety instructions 12 Safety precaution 16 Safety symbols 8 Scope of supply 23 Select operation mode 47 Selector switch 31 Service request if Slider 0000 32 Standard pressure display 30 34 Status bar 36 Switch to control mode 43 System compontens VACU UBRAND 20 System requirements 20 System start stop 52 T Target groups 15 Technical data
2. Example slider T00 Ds 100 U Tooltip 63 Emang Slider AI Text box for display and settings Slider button Off Off e 2 Use the text box for fine tuning or direct settings L gt On smartphones and tablets the text box can be hidden behind a touch keyboard Turn your mobile device into portrait orientation or scroll for more display Settings are also possible in hidden state 32 BA N 999279 17 10 2014 Control element 5 Buttons are the control elements of the remote control All buttons are labeled with text and or icons DISPLAY AND OPERATING ELEMENTS 2 2 Buttons Button examples Text and Icon Text or Icon Homepage Graphic Select language O Mode Vent Start Button labeled with icon Icon on button Meaning View mode monitoring by remote control Pressure value bargraph Page forward next page OK apply data settings Call up data logger menu download Increase value Parameter set control parameter Meaning Control mode remote control t monitoring Diagram pressure vs time Page backward previous page Cancel discard set tings close window Open drop down list Decrease value Language adjustment BA N 999279 17 10 2014 33 DISPLAY AND OPERATING ELEMEN
3. 31 5 21 Types of operating elements 31 O22 DULONG s ex HE ane EE ER FEE EE ood ere te 33 5 3 Display elements SEE aaa 34 5 3 1 Pressure reading 0000 eee eee 34 5 3 2 Display symbols 0 0 0 0 ee ee 35 5 3 3 Title bar status bar SE SE SE SE 36 D040 FOOD a4 EE OE EE OE IE Be oS 37 5 4 Text oe AE EP EER EE OE EE ET N EG 3 6 Operation 38 6 1 Starting VACUUsCONTROL application 38 6 2 Language setting aaa 39 6 3 Remote control View mode 40 6 3 1 Display pressure reading 40 6 3 2 Display graphic 4 EE SS SES SE Se SE 41 6 3 3 Quick navigation a 42 6 4 Remote control mode Control 43 6 4 1 Display pressure reading 44 6 4 2 Display graphic 0 0 0 0 ee ee 45 6 4 3 Mode selection EE EE eee es 46 6 4 4 Parameter settings 0 0 0000 c eee ae 48 6 4 5 System start stop 0 0 eee 52 6 4 6 Venting the system Vent nannaa anaana anaa 53 6 4 7 Download process data Data logger 54 6 4 8 Quick navigation n a aaa aaa aaa eee 57 7 Network configuration and updates 58 11 Network configuration SESSE SE SE ce eee 59 1 1 1 Menu network configuration 59 7 1 2 Password management SESSE SES Es 61 7 2 Updates 00 62 L21 CVC SOOBD sa
4. gt Incorrect address entered v Check plug connection into address bar of web Check IP address browser v Replace defective parts Adapter defective VACUU CONTROL gt Display unit switched off or v Switch on display unit View Con interface will not defective v Install current web browser trol Admin display in web gt Hardware or web browser see chapter 3 2 System browser window do not meet system require requirements ments v Check address in browser Web page can not be found window gt Password input incorrect v Enter password v Inform your system adminis trator Data logger no Data memory of adapter has v Keep adapter connected to View Con measured values been deleted due to a power CVC until all measured val trol Admin available failure ues have been downloaded gt CVC 3000 separated from v Save the measured values mains power source first then run the update gt Voltage supply from CVC v Do not operate power switch to adapter has been inter rupted e g SUB D plug has been removed Firmware has been updated Patch cable con gt Computer is not support v Plug crossover adapter into Admin nected directly ing Gbit s Ethernet standard Ethernet connection of com to computer but LAN Auto MDI X puters Ethernet cable no connection is crossover adapter com established puter User interface is JavaScript not enabled v Enable JavaScript in your Control not dis
5. 13 Technical information 13 Technical support 66 Term definition 11 Terms of service 16 Textbox 37 Titebar 37 Title bar status bar 36 Tooltip nananana oe wn ee Rd HE 37 Troubleshooting table 68 Turbo mode 49 U Updates 62 User group capabilities 16 User interface 30 user permissions 16 V Venting the system Vent 53 View ee 15 W Warning levels 9 WLAN approval 19 WLAN connection 2 Working conditions 12 19 Manufacturer VACUUBRAND GMBH CO KG Alfred Zippe Str 4 97877 Wertheim GERMANY Phone Head office 49 9342 808 0 m Sales 49 9342 808 5550 m Service 49 9342 808 5660 Fax 49 9342 808 5555 E Mail info vacuubrand com Web www vacuubrand com vacuubrand Technology for Vacuum Systems 17 10 2014 24012014 1 7 TDD2 CONTROL CVC Version 999279 EN VACUU
6. Please press the Update Button to start the update process Update v Update starts 7 Wait for the update to terminate gt see progress bar Vv VACUU CONTROLS restarts BA N 999279 17 10 2014 vacuubrand NETWORK CONFIGURATION AND UPDATES 7 2 3 User interface GUI Due to product improvements or modifications or updates of the LAN WLAN firmware it may be necessary to update the GUI Updating VACUUsCONTROL GUI Updating GUI 1 Turn on your CVC 3000 controller with the user interface VACUU CONTROL adapter connected 2 Use your web browser to navigate to the VACUUeCONTROL interface Switch to Control mode Click Quick navigation and then click VACUUeCONTROL GUI 5 Enter the required password in the login window KN OW vl VACUU CONTROLS GUI Update menu opens 6 Follow the on screen instructions 2 Please press the Browse Button and select the downloaded file Datei ausw hlen Keine ausgew hlt 3 Please press the Update Button to start the update process Update v Update starts vi progress bar shows update status 7 Wait for the update to terminate v On screen message on web browser BA N 999279 17 10 2014 65 RESOLVING PROBLEMS vacuubrand Technical support Example User interface GUI in case of malfunction 66 8 Resolving problems NOTICE Possible material damage due to improperly executed trou
7. WLAN adapter 4 O CVC 3000 vacuubrand GEE WLAN VACUUCONTROL Connected INSTALLATION AND CONNECTION 4 3 Establishing initial connection 4 3 1 WLAN connection The VACUU CONTROL WLAN adapter is the wireless remote interface to your CVC 3000 As delivered the WLAN adapter acts as SoftAP and is therefore displayed as WLAN network Con nect your end devices via WiFi directly to the CVC 3000 Selecting WLAN network 1 Turn on the CVC 3000 that your WLAN adapter has been connected to 2 Switch on WLAN WIFi at your end device M Scan for available WiFi networks 3 Wait until VACUUCONTROL appears in the list of detected WiFi networks If your end device connects automatically to ano ther network 2 disconnect from this network IMPORTANT 2 switch off automatic WiFi connection and cy select VACUUCONTROL in the list of available networks 4 Select ACUUCONTROL as network connection Depending on the end device connecting may take some time vi End device connected to WLAN adapter table In case of a direct WiFi connection to your end device no internet will be available We therefore recommend to integrate the WLAN adapter into your PC network for instance using a WLAN router see chapter 7 Network configuration and updates or ask your company s IT department for support i 2 For further help see chapter 8 2 Troubleshooting 2 5 Sof
8. continuously hh mm ss BA N 999279 17 10 2014 41 OPERATION uubrand Ee Quick navigation in view mode Meaning 42 Alternatively the pressure reading or pressure time plot can be accessed via the quick navigation Quick navigation also pro vides access to additional menus 6 3 3 Quick navigation Quick navigation view mode VACUU LAN Quick navigation Homepage Graphic Select language About VACUU CONTROL Ga 1 Homepage 3 Select language Switch to homepage of Open select language menu View mode bargraph 2 Graphic 4 Open menu with information Open display graph about VACUU CONTROL pressure vs time 2 Grayed out buttons and elements cannot be operated They are optional or password protected BA N 999279 17 10 2014 OPERATION 6 4 Remote control mode Control Misuse can cause physical injury or damage to property Misuse or improper operation causes harm and can lead to physical injury or damage to property 2 Observe all safety instructions of these instructions for use and the safety instructions of the remote controlled device gt Use the system only for its intended use 2 Use the system only with knowledge to function and operation gt Never operate critical processes by remote control 2 Prevent hazards caused by parallel entries such as simultaneous operation via several end devices Arrange opera
9. 2014 OPERATION 6 4 2 Display graphic In addition to the bargraph the display can be switched to a dia gram similar to Graphic at CVC 3000 Open graph diagram Click on selector switch Graphic placed at the bottom left Mi Selector switch Graphic marked v Display with diagram appears View graph pressure over time i rise e Pump down aie Ceecwbrard yi CVC 3000 and VACUU CONTROLS Vent sen 4 Meaning 1 Pressure 3 Graph frame unit according to preset diagram pressure vs time ting at CVC 3000 mbar Torr hPa 2 Time unit 4 Enabled control elements gt continuously hh mm ss BA N 999279 17 10 2014 45 OPERATION Mode meanings Mode Mode d Fr Ll View mode menu Meaning 46 s when operation has been stopped to open the menu for select ing the operation mode 6 4 3 Mode selection Mode has two different options during running operation to switch from Pump down to Vac control to Auto mode Open menu Mode stopped operation gt Click on the Mode button v Button marked v Mode menu is displayed Mode menu 998 mbar PF vecunbrand N _ Mode o T Pump down AQ Vac control 0 Auto mode AA Program B VACUU LAN 6 Cancel OK 1 Title bar with menu name 2 Pump down gt Continuous pumping with pressure and time target gt VAR
10. EE AE AA AYY 62 7 2 2 LAN WLAN firmware 000000 eae 64 7 2 3 User interface GUI 0 0 0A 65 BA N 999279 17 10 2014 CONTENT 8 Resolving problems 66 8 1 Error displaV ss ss Es ER ae EE KEER HER RE EE N NG 66 8 1 1 External errors 0 00 0 0 aa 66 8 1 2 Internal errors 000 ee 68 8 2 Troubleshooting table ESE EES EE SE EE e 68 8 3 Reset to factory default settings Reset 12 9 Appendix 73 9 1 Technical information SS eee T3 91 1 Technical data SS ee SS 13 91 2 Rating plate ESE EE ESE ee 14 9 2 Service EES a ee 16 9 21 Terms of service 0 000 0000 eee eee 76 9 2 2 Service reduest SS SE SS ES a rd 9 2 3 RetumM SS SS SS Tf SEE EC je ER TT EE OE sence 78 9 4 IndeX aaa ee 19 BA N 999279 17 10 2014 O CONTENT 6 BA N 999279 17 10 2014 vacuubrand INTRODUCTION 1 Introduction This manual is part of your product It provides important instruc tions for safe use of the product Read this manual completely in order to understand proper use of your product 1 1 User information Safety Instructions for use Read this manual thoroughly and completely before using the and safety VACUU CONTROLS software Keep this manual in an easily accessible location Proper use of the CVC 3000 and VACUU CONTROL software is essential for safe operation Comply with all safety instruc tions provide
11. Please contact our Service department if you are unable to resolve an error using the information provided in this table BA N 999279 17 10 2014 71 RESOLVING PROBLEMS vacuubrand LAN adapter 12 8 3 Reset to factory default settings Reset Damage due to interrupted connection to the vacuum system lf VACUUeCONTROL adapter is reset to factory default settings contact to the vacuum system will be lost The remote control will stop functioning 2 Stop any vacuum process prior to resetting to factory settings 2 Only authorized personnel may carry out a reset The remote control can be reset to factory settings directly at the LAN or WLAN adapter The latest VACUU CONTROLS Firmware and GUI updates are preserved Data like measured values in the data logger or passwords etc are deleted For resetting the LAN WLAN adapter has to be connected to the controller CVC 3000 Reset WLAN adapter 1 Switch off pumping unit CVC 3000 controller 2 Use a straight stable wire 0 8 1 mm 25 mm 3 Insert the wire into the small opening at the LAN WLAN adapter 4 Press the reset push button and keep pressed for about 10 seconds while switching on the pumping unit CVC 3000 vi Perceptible movement of push button M VACUU CONTROLS reset to factory settings Reset LAN adapter 1 Use a straight stable wire O 0 8 1 mm 25 mm 2 Insert the wire into the small opening at the LAN
12. exceeded sllesOO v a Venting valve switched on open VENT In line valve switched on open 4 Ta 5 3 3 Title bar status bar Status bar regular Like on CVC 3000 the status bar of remote control indicates the current operation mode Mode and the elapsed process time o Auto mode 00 00 33 vacu Rut m i a iii ma 4 EE TE RO EE HR SE BA N 999279 17 10 2014 vacuubrand DISPLAY AND OPERATING ELEMENTS Status bar special JE Pump down gt ID Pump down gt Status bar green process end reached Status bar red malfunction fault Tidebar OO In menus the status bar displays the title of the opened menu Example title bar with Select language 1010 mbar Gacubrand JE menu name 5 3 4 Tooltip The tooltip is a common graphical user interface element A small hover box with quick information about the button may appear automatically when the cursor or pointer is hovered over a but ton without clicking it 5 4 Text box Text boxes allow the user to enter text or values to be used by the program or to display the adjusted value Examples for entries are to adapt numeric values to assign passwords web form for network configuration Click on a text box when it is framed and the cursor is blinking the text box is ready for input Grayed out text boxes have purely display function framed tex
13. manuals of the system controlled by remote control to know the functioning of the system which you want to operate by remote control Any other use is considered to be improper use In this case the safety and the protection of the system may be compromised 2 1 2 Improper use Using the product in contrary to its intended use could result in injury or damage to property Improper use includes using the system contrary to its intended use s operation with obvious malfunctions BA N 999279 17 10 2014 vacuubrand SAFETY INSTRUCTIONS Improper use operating the vacuum system by remote when it is incomplete or dismantled unauthorized network settings unauthorized change of passwords 2 1 3 Foreseeable misuse Additionally to improper use there are types of use dealing with remote control which are generally prohibited Reasonably Using remote control without knowledge about the connected foreseeable vacuum system or vacuum controller misuse Modifications of hardware and firmware s Unobserved remote control of critical processes BA N 999279 17 10 2014 13 SAFETY INSTRUCTIONS vacuubrand Access rights and password management Screen shot cutout password management Meaning access rights for target groups 14 2 2 Access rights and password management The Network Configuration menu allows password management to be set up It also allows for certain functionality to be e
14. pressure time unit OU 600 400 200 N dd 0 5 3 2 Display symbols During operation further symbols are indicated on the display Display symbols during operation Icon Meaning Two point control pressure in hysteresis pump switched off Two point control pressure in hysteresis pump switched on VARIO control pump down to setpoint Auto mode detect boiling point Detect detect boiling point VARIO control vacuum has reached the setpoint Auto mode boiling point reached Turbo mode switched on for VARIO in combination with turbomolecular pump 1 5 for reasons of space symbols can not be indicated in portrait orientation onscreen of some mobile devices BA N 999279 17 10 2014 35 DISPLAY AND OPERATING ELEMENTS vacuubrand Display symbols display icons fault free operation gt Examples status bar VACUU CONTROL Cutout status bar CVC 3000 36 Meaning Coolant valve switched on Pump running in combination with percentage value motor speed only valid for VARIO systems Mode VACUUsLAN delay time elapses Status bar green defined period reached Pump down continuous pumping Pump down lower limit value reached VAGUU LAN pump down to setpoint Vac control with two point control pump down to setpoint VAGUU LAN pressure increase to switch on pressure Vac control preset maximum
15. to identify bookmark and tab e g PC3001 LAB2 Ae BA N 999279 17 10 2014 29 DISPLAY AND OPERATING ELEMENTS 5 Display and operating elements 5 4 VACUU CONTROL remote control If the connection has been correctly established the VACUU CONTROL user interface will be displayed in your web browser Depending on your end device the display may auto matically adjust to portrait or landscape orientation 5 1 1 User interface User interface in general Example User interface Vac control D leldungen insgesamt Meaning 1 Selector switch gt View mode View gt Control mode Control 2 Status bar Title bar Current operating mode mode Process time gt Menu 3 Display area Standard pressure display actual pressure value Pressure vs time diagram 4 Button gt Quick navigation 5 Selector switch gt Pressure reading bargraph Graphic pressure vs time diagram 6 Buttons gt Enabled control ele ments within control mode Control 30 BA N 999279 17 10 2014 vacuubrand DISPLAY AND OPERATING ELEMENTS 5 1 2 Work interface KI Depending on access rights the user interface has different O application areas View vlew mode view mode B control mode s Control control mode All operating elements required for View are displayed within view mode More operating elements for control o
16. 000 samaan a 10 11 Delete data 54 Design of steps 10 Display and operating elements 30 Display conventions 9 Display elements 34 Display pressure reading 40 44 Download 54 55 E Eliminate source of danger Enabled control elements end device 19 Environmental protection 18 Error display 66 Error messages GUI 68 Establishing LAN connection 28 explosive mixtures 17 F Fault Cause Remedy 68 Features 20 File extension 62 Foreseeable misuse G graphic diagram graphic pressure over time GUI user interface H Hardware components 22 HI mode 49 holder for WLAN adapter 24 BA N 999279 17 10 2014 Improper use 12 13 Included materials 23 Installation and connection 24 Intended use 12 Internal errors 68 IP address factory setting 29 J Javascript 21 L labeled buttons 33 LAN connection 28 Language selection 39 Language setting 39 LAN version 22 LAN WLAN firmware update Larger vacuum systems Login input mask 58 LOGO ereere APA 18 M Malfunction symbols Memory capacity Menu Data logger 55 Menu network configuration 59 mode Control
17. 14 1 2 4 Term definition INTRODUCTION Product VACUU CONTROLS specific terms VACUU CONTROLS LAN VACUU CONTROLS WLAN VACUU LANS Web based application as remote control for vacuum controller and gauges made by VACUUBRAND Adapter LAN for connection to vacuum controller CVC 3000 or vacuum gauge DCP 3000 for integration into LAN PC networks Adapter WLAN for connection to vacuum controller CVC 3000 or vacuum gauge DCP 3000 for integration into WLAN PC networks Local vacuum network for laboratories LAN or WLAN adapter can be connected to all pumping units and vacuum systems equipped with the CVC 3000 vacuum controller or a DCP 3000 vacuum gauge gt Please read the manual VACUUeCONTROL with DCP 3000 if you use DCP 3000 from software version V2 0 BA N 999279 17 10 2014 SAFETY INSTRUCTIONS vacuubrand Intended use Improper use 2 Safety instructions All safety instructions must be observed by all individuals working with the products described here 2 1 Working conditions 2 1 1 Intended use The VACUUsCONTROL application is a web based remote con trol application that monitors controls and logs data when con nected with a compatible VACUUBRAND vacuum pumping unit and controller Intended use also includes the following observing safety information of document Safety Information for Vacuum Equipment s observing these instructions for use s observing
18. Error message shown on user interface v Remedy Controller is switched off v switch on controller You are using an outdated browser that is not compatible with this software Please try again with a later browser version v install the latest software version of the web browser see 3 2 System require ments chapter Network configuration changed CVC 3000 needs update to work properly with VACUUeCONTROL Go to update page This controller is currently not supported No communication with controller Please check settings v reload site v wait consider booting time for WLAN adapter v check network connection select and connect again v update CVC firmware see chapter Updating CVC 3000 firm ware v contact our Service and ask for a list with compatible devices v connect controller v check baud value at controller CVC Con figuration Baud 19200 v check RS232 settings at CVC and if nec essary reset to factory settings v system administrator reset VACUUeCONTROL to factory settings Update in progress Please wait v wait until update has finished Connection interrupted Please reload page JavaScript disabled v reload page v enable JavaScript for your web browser Update failed Check file v check update file or restart download Link 8 2 Troubleshooting table Fault gt Cause Personnel v Remedy Network out
19. IO pumping with adjustable speed pumping speed Vac control Control to a preset vacuum level 4 Auto mode gt Control of a VARIO pump in auto mode find and adjust boil ing pressure of solvents automatically precise vacuum adap tion even with variable process conditions gt Alternatively for controllers of detect series boiling point determination in two point control without vacuum adaption 5 Program gt Ten programs with vacuum and time targets Each program with ten program steps can be edited saved or loaded VAGUU LAN Vacuum control optimized for vacuum network O BA N 999279 17 10 2014 OPERATION gt For details about the operation modes and information on use please refer to the manual of the remote controlled device Select operation mode Auto mode Bl 1 Click on the required operation mode ETE M Selected radio button is marked GD 2 Confirm your selection with OK M View switches to the previous display M Status bar displays the selected operation mode During operation to switch from Pump down to Vac control Mode gt During Pump down operation click on button Mode dim Button momentarily marked m M status bar displays Vac control to switch from Vac control to Auto mode Mode 2 During Vac control operation click on button Mode air v Button momentarily marked vi status b
20. Language setting I ubrand is Deutsch O English OPERATION 2 Ask your system administrator for the access password if a log in pop up appears when calling up VACUU CONTROLS mi o 6 2 Language setting When first started the VACUUeCONTROL uses the same lan guage as preset at controller CVG 3000 When at CVC 3000 a language is pre set which is not yet sup ported by VACUUsCONTROL then the user interface is dis played in English by default The set languages at CVC 3000 and for VACUUeCONTROL GUI on your browser the display may vary arbitrarily This means by setting language for one device does not thereby change the other device settings Selecting a language 1 Click on the logo vacuubrand M Quick navigation opens 2 Click on the globe icon or click on Sprachauswahl Select language from the list M Menu Select language opens 3 For example click on radio button English 4 Confirm your selection with OK M Graphical user interface appears in English 1 gt VACUUeCONTROL supports the same languages as the controller CVC 3000 BA N 999279 17 10 2014 39 OPERATION Remote control View mode Ge Example Pressure reading CVC 3000 and VAGUU CONTROLS Pump down Meaning 40 Monitoring of the remote control displays the status of current pressure values at CVC 3000 on your end
21. Maximum limit for vacuum level If pressure mbar exceeds this limit the pump begins to pump down Adjustment range O 1060 Delay min Period for which the pump will attempt to maintain Set vacuum level If no pressure increases are detected before the time period Delay expires vacuum level will be allowed to rise to Switch on level Adjustment range O 300 minutes BA N 999279 17 10 2014 51 OPERATION 6 4 5 System start stop DANGER Risk of hazard when operating critical processes by remote control Operating critical processes by remote control can lead to serious injury or damage to property gt Do not operate critical processes by remote control without direct access gt Only start procedures by remote control which can be operated without personal observation Start Stop of vacuum control via remote control is similar to start stop at CVC 3000 with start stop button Starting the system Start Click on the Start button dm v Button marked v vacuum process runs Stopping the system 2 Click on the Stop button v Button unmarked v vacuum process stopped 52 BA N 999279 17 10 2014 OPERATION 6 4 6 Venting the system Vent DANGER Danger of explosion when venting with air by forming explosive mixtures Depending on the process venting can form explosive mixtures gt Never vent processes with air which can form an explosive mix
22. TICE Notice for a potentially harmful situation Note if disregarded can lead to material damage Additional notes Convention for IMPORTANT Information or specific use recommendation additional notes which must be observed Helpful tips 1 gt Additional information BA N 999279 17 10 2014 9 INTRODUCTION Design of steps Graphic Abbreviations Individual ste sinale ste 2 Do the described step vi Result of action Multiple steps 1 First step 2 next step v Result of action Follow steps in the described order 1 2 3 Abbreviations abs ATM CSV CVC 3000 DCP 3000 DHCP GUI hh mm ss hPa IP LAN Max mbar Min RC SoftAP Torr VAC WiFi WLAN absolute standard atmospheric pressure see bar graph comma separated values a spreadsheet compatible format vacuum controller vacuum gauge dynamic host configuration protocol for dynamically distributing IP addresses graphical user interface period or time hour minute second pressure unit hectopascal internet protocol network protocol local area network wire connection for computers in a local network maximum value pressure unit millibar minimum value remote control Software Acess Point pressure unit 1 Torr 1 33 mbar vacuum see bar graph WLAN standard here synonym for WLAN wireless local area network wireless connection for computers BA N 999279 17 10 20
23. TS vacuubrand Text on button Example standard pressure graphic bargraph 34 Button labeled with text Button Meaning Select mode of operation Mode During operation to switch from Pump down to Vac control gt During operation to switch from Vac control to Auto mode gt During operation to switch from Auto mode to Vac control Vent system press key gt 2 sec venting to vent atmospheric pressure Start Start vacuum process ED Stop vacuum process update Executes update command 5 3 Display elements 5 3 1 Pressure reading Standard pressure displa Key element of VACUU CONTROL is the standard pressure display the so called bargraph The bargraph is displayed in syn chronization with the display on the connected CVC 3000 Auto mode 00 00 33 Qroubrand za FT Display symbols example Displays current pressure mbar mbar La O BA N 999279 17 10 2014 Example graphic diagram Display symbols display icons fault free operation DISPLAY AND OPERATING ELEMENTS Pressure Time graph In addition to the bargraph the display can be switched to a dia gram which shows pressure vs time This diagram is similar to the selection Graphic on CVC 3000 222 mbar Cm o Auto mode 00 00 27 Ceecwbrrd gt g Display symbols example 1000 N Druck mbar Display pressure history
24. Technology for Vacuum Systems WEB BASED REMOTE CONTROL FOR CVE SOOO VACUU CONTROL o IB Vac control Gwede CVC 3000 Instructions for use EN Original instructions BA N 999279 IMPRINT Original instructions Keep for future use This manual is only to be used and distributed in its complete and original form It is strictly the users responsibility to check carefully the validity of this manual with respect to his product Manufacturer VACUUBRAND GMBH CO KG Alfred Zippe Str 4 97877 Wertheim GERMANY Phone Head office 49 9342 808 0 m Sales 49 9342 808 5550 m Service 49 9342 808 5660 Fax 49 9342 808 5555 E Mail info vacuubrand com Web www vacuubrand com Thank you for purchasing this product from VACUUBRAND GMBH CO KG You have chosen a modern and techni cally high quality product 2 BA N 999279 17 10 2014 CONTENT TABLE OF CONTENT 1 Introduction 7 11 User information aaa T 1 2 About this document 4a 8 1 2 1 Symbols and icons 0 0 ce ee 8 1 2 2 Display CONVENTIONS 2 446 sins EE DERE aeans ma 9 1 2 3 Abbreviations 00 Es Es EE ee 10 1 2 4 Term definition SE EE EE eee ee ee 11 2 Safety instructions 12 2 1 Working conditionS EES ES EE SE eee 12 2 1 1 Intendeduse ss Es EE ee 12 2 1 2 Improper use ss ee 12 2 1 3 Foreseeable misuse 13 2 2 Access r
25. VACUU CONTROLS into your network and to assign access rights for users A password entry is required to access Network configuration 7 1 1 Menu network configuration Menu WLAN version Network configuration re Network type Infrastructure Security type SSID vacuubrand DHCP client IP address 192 168 1 111 Subnet mask 255 255 255 0 Default gateway 192 168 1 111 Primary DNS 192 168 1 111 Secondary DNS 0 0 0 0 NetBIOS name VACUUCONTROL Device name VACUUCONTROL MAC Adresse 00 1E C0 10 3C D8 BA N 999279 17 10 2014 59 NETWORK CONFIGURATION AND UPDATES 60 Network configuration menu LAN factory settings Meaning setting options in network configuration Menu LAN version DHCP client IP address Subnet mask Default gateway Primary DNS Secondary DNS NetBIOS name Device name MAC Adresse Network configuration on PD 192 168 1 111 258 2552550 192 168 1 111 192 168 1 111 0 0 0 0 VACUUCONTROL VACUUCONTROL 00 1E C0 BB 53 55 Meaning of setting options Settings Network type Security type SSID Description Selectable Options Infrastructure SoftAP Select WLAN security type None Name of wireless network DHCP client IP address Subnet mask Default gateway Primary DNS secondary DNS NetBIOS name Device name MAC address Dynamic Host Configuration Protocol Protocol for nami assignment of IP address es in your LAN On use dyna
26. WLAN adapter 3 Press the reset push button and keep pressed until both the yellow and the green LED at the Ethernet connection switch off simultaneously vi Perceptible movement of push button M VACUU CONTROLS reset to factory settings 1 5 diameter BA N 999279 17 10 2014 Type Technical data 9 Appendix 9 1 Technical information APPENDIX Type RC adapter VACUU CONTROLS 9 1 1 Technical data Electrical data Power supply via CVC 3000 Plug connection RS 232 SUB D 9 pole Degree of protection IP 40 Dimensions and weight Dimension LAN adapter Dimension WLAN adapter 90 mm x 55 mm x 35 mm 3 54 in x 2 16 in x 1 37 in Af mm x 114 mm x 26 mm 1 85 in x 4 48 in x 1 02 in Signal strength IP factory setting Data storage capacity SUB D cable length 420 mm 16 53 in Weight LAN Adapter 236 g Weight WLAN adapter holder 1139 LAN version Web based remote control VACUU CONTROLS LAN Network name VACUUCONTROL IP factory setting 192 168 1 111 Data rate 100 Mbps Data storage capacity 2 MB WLAN version Web based remote control VACUU CONTROLS WLAN Network name VACUUCONTROL Network standard 802 119 Network type SoftAP infrastructure Data rate max 54 Mbps Frequency range 2 405 2 48 GHz Safety open WPA PSK WPA2 PSK Output power 16 dBm Sensitivity 88 dBm RSSI supported 192 168 1 111 2 MB BA N 999279 17 10 2014 ko APPENDIX Example Rating plate LAN
27. ac control Menu 787 mbar Vac control Coacubrand JE control parameter aminan Vac control Set vacuum mbar 1 Speed 50 a Maximum mbar Off mm Duration min 216 mmm Meaning Parameter Meaning Set vacuum Adjustment of lower value for two point control or mbar precise for VARIO pumps Speed Hysteresis Maximum mbar Duration min Delay min Adjustment range O 1060 O Turbo mode Speed parameter for pump down Adjustment range 1 101 101 HI mode Control parameter for 2 point controllers Adjustment range 0 1 1060 O AUTO Adjustment of upper pressure If this limit is exceeded the vacuum pump switches off Adjustment range 0 1 1060 O OFF Default value for process run time Process time begins when user presses Start button Adjustment range O 1440 0 OFF Delay time for an optional coolant valve Coolant valve is closed after Delay time has been reached Turbo mode auto adapting vacuum controller for best ultimate vacuum HI mode optimum speed for the respective pressure recommended setting BA N 999279 17 10 2014 49 OPERATION Parameter Auto mode 787 mb Menu Auto mode Ma Crecwbrand YG control parameter Auto mode Sensitivity Low High Speed HI Minimum mbar Off Duration min 216 Meaning Parameter Meaning Sensitivity Motor speed responsiveness setting Speed Minimum mbar Duratio
28. adapter Example Rating plate WLAN adapter 74 9 1 2 Rating plate 1 gt In case of malfunction please note type and serial number on the rating plate gt When contacting our service department name us product type and serial number With this information we can offer selective support and advice for your product Rating plate LAN adapter Manufacturer Type Serial number Date of construction Address Rating plate WLAN adapter Manufacturer VACUUBRAND GMBH CO KG Type Serial number Date of construction Address Approval Information WLAN AVACUUBRAND GMBH CO KG Alfred Zippe Str 4 vacuubremd 5 97877 Wertheim Made in Germany VACUU CONTROL LAN 2014 03 EEN N Alfred 7ippe Str 4 vacuubrae 97877 Wertheim Made in Germany VACUU CONTROL WLAN SIN 12345678 2014 03 C Contains Transmitter Module USA FCC ID WWOMRF24WG0MA MB Canada IC 76934 24WGOMAMB for further information see manual BA N 999279 17 10 2014 VACUUBRAND GMBH CO KG SIN 12345678 mami E 2014103 a a ee ed Made i APPENDIX WLAN approval WLAN approval FCC USA FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resid
29. ar display If the screen freezes while updating reload the page v On screen message in web browser Iv VACUU CONTROLS restarts v an icon is displayed on the CVC 3000 display when con nected to VACUUsCONTROL BA N 999279 17 10 2014 63 NETWORK CONFIGURATION AND UPDATES vacuubrand Icon on CVC display Updating firmware VAGUU CONTROLS adapter 64 Possible icons on CVC display Icon Meaning Icon Meaning VACUU CONTROL Controller in remote 6 mode only controllable adapter connected via remote control 7 2 2 LAN WLAN firmware Along with your VACUUeCONTROL LAN adapter or WLAN adapter you automatically receive the current VACUU CONTROLS firmware Due to product improvements or modifications it may be necessary to update the firmware Updating VACUUeCONTROL firmware 1 Turn on your CVC 3000 controller with the VACUUeCONTROL adapter connected 2 Use your web browser to navigate to the VACUUeCONTROL interface 3 Switch to Control mode 4 Click Quick navigation and then click VACUU GONTROL Firmware 5 Enter the required password in the login window M VACUUeCONTROL Update menu opens 6 Follow the on screen instructions 1 Please download the appropriate VACUU CONTROL Firmware from our website here PJ Please press the Browse Button and select the downloaded file Datei ausw hlen Keine ausgew hlt Gr
30. ar displays Auto mode 2 5 only valid for VARIO pumps BA N 999279 17 10 2014 47 OPERATION 6 4 4 Parameter settings This button corresponds to the selection knob of the CVC 3000 TE Parameter is a menu to fine tune the selected operation mode Parameters can also be adjusted during operation Open menu Parameter Click on the button with the gear wheel icon Jim v Button marked v Parameter menu is displayed The display of the Parameter menu depends upon the mode selected and the remote control device Parameter Pump down Menu 787 mbar vacuubrand control parameter kump sown Pump down Speed 50 me Minimum mbar Off Duration min 216 CE Meaning Parameter Meaning Speed Only VARIO motor speed parameter for pump down Adjustment range 1 101 101 HI mode Minimum setting vacuum value which has to be reached mbar When this value is reached the vacuum controller switches off or the in line valve closes Adjustment range 0 1 1060 0 OFF Duration min Default value for process runtime from Start on Adjustment range 0 1440 0 OFF Delay min Delay time for an optional coolant valve HI mode optimum speed for the respective pressure recommended setting 3 5 Screenshots of Parameter are examples with VARIO pump with pressure unit in mbar 48 BA N 999279 17 10 2014 OPERATION Parameter V
31. atus vacuum process control 1 Start gt 0 Stop 2 End 56 BA N 999279 17 10 2014 lubrand E Quick navigation control mode Meaning OPERATION 6 4 8 Quick navigation You can alternate between viewing the pressure reading and pressure time graph by using the quick navigation button Quick navigation also provides access to a range of other pa rameters Quick naviaation control mode o IB VACUU LAN Quick navigation Homepage Graphic Select language Data logger 1 N i Network configuration h F Update TM N o O O 98 8 CVC DCP Firmware o 9 9 8 About VACUU CONTROL g 1 Homepage 5 Network configuration Switch to homepage of Open network configuration control mode bargraph 2 Graphic 6 Update Open display graph gt CVC firmware pressure vs time gt VACUU CONTROL firmware gt VACUU CONTROL GUI 3 Select language 7 Open menu with information Open select language about VACUU CONTROL menu 4 Data logger Open data logger menu Password protected sensible menus are for system administrator only BA N 999279 17 10 2014 57 NETWORK CONFIGURATION AND UPDATES vacuubrand Network configuration Example Login input mask 58 web browser 1 Network configuration and updates Communication abort due to incorrect network configuration Incorrect network configura
32. bleshooting Technical support To identify errors and potential remedies please refer to the troubleshooting table Fault Possible cause Remedy In case you need additional assistance please contact our Service department 8 1 Error display 8 1 1 External errors Error messages from the vacuum system are displayed both on the CVC 3000 controller and on the VACUUeCONTROL interface User interface in case of external errors gt Pump down di 1 Red title bar 2 Display symbol in case of malfunction within the bar graph BA N 999279 17 10 2014 vacuubrand RESOLVING PROBLEMS Display symbols in case of malfunction Display symbols Icon Meaning display icons In case of malfunction Warning External error Catchpot full with liquid level sensor only Fault at coolant valve Fault at pump OOP Ed Fault at venting valve oe Fault at in line valve gt Error messages of vacuum pumps or valves are often caused by disrupted data connections check cable connections gt Refer to the instructions for use of the remote controlled devices for further information on troubleshooting BA N 999279 17 10 2014 67 RESOLVING PROBLEMS 8 1 2 Internal errors Error messages that result from internal errors of the remote control are displayed directly in the web browser Error messages shown on user interface GUI
33. brand com BA N 999279 17 10 2014 APPENDIX 9 2 2 Service requests Contact service request 1 Contact your local dealer or our service department and service order 2 Inform us which service features you require 3 Send us your service request providing the following informa tion serial number and type from rating plate a short description of your request e g error description for repair order exchange etc v Our service will provide you with a RMA number vi Clearance for return 9 2 3 Return Sending in 1 Pack your product securely for transportation Mark the RMA number on the outside of the packaging 2 Send in your product Send in your product return BA N 999279 17 10 2014 Tf APPENDIX 18 9 3 Glossary Crossover CSV file format Firmware Bookmark Patch cable Shortcut Web application Web browser For direct wiring of two computers of the same type via crossover cable or crossover adapter Due to auto MDI X capability usually crossover cables and crossover adapters are not necessary comma separated values Within csv files tables and lists of variable lenghts can be mapped The data log ger provides the measured values in csv Software that is embedded in electronic devices The web application for remote control VACUUeCONTROL is permanently installed on the adapter LAN or WLAN The firmware is functionally fixed to the hardware which mea
34. d In addition to this manual adhere to any relevant local accident prevention regulations and comply with industrial safety regula tions General General VACUU eCONTROL software is an easy to use web based information application Display illustrations of these instructions are explained by exam ples with a computer web browser The VACUUeCONTROL application uses a standard internet browser The illustrations in this manual are provided as examples They are intended to aid in your understanding of the proper use of the product When giving VACUU CONTROL to a third party also hand out these instructions for use VACUUBRAND GMBH CO KG reserves the right to modify or change the product design and or technical specifications at any time without advanced notice BA N 999279 17 10 2014 T INTRODUCTION vacuubrand Copyright Contact us Safety symbols Additional icons Copyright VACUU CONTROL is available as an add on consisting of adapter with installed software and web based graphical user in terface GUI Unauthorized program modifications or software copies are not allowed The content of these instructions for use is protected by copy right Only copies for internal use are allowed e g for profes sional training VACUUBRAND GMBH CO KG Contact Please ask for replacement in case of incomplete instructions for use Alternatively you can download instructions for use o
35. device View mode is for personnel with read permission View mode can be assigned with password by the administrator see chapter 7 1 2 Password management 6 3 Remote control View mode NOTICE Without password protection data are accessible to everyone 6 3 1 Display pressure reading Once VACUU CONTROL is opened via web browser the mea sured pressure of the vacuum controller CVC 3000 will be dis played View current pressure readin Pump down Coacuubrand JE 1 VAC 4 Numerical value gt Vacuum gt current pressure 2 Bargraph 5 ATM graphical element for atmospheric pressure pressure reading 3 Pressure Unit according to preset ting at CVC 3000 mbar Torr hPa BA N 999279 17 10 2014 OPERATION 6 3 2 Display graphic In addition to the bargraph the display can be switched to a dia gram similar to Graphic at CVC 3000 Open graph diagram Click on selector switch Graphic placed at the bottom left IM Selector switch Graphic is marked v Display with diagram appears View graph pressure over time gt Example 60 Pump down om Coacubrand JE Graph CVC 3000 and VACUU CONTROLS NS Meaning 1 Pressure 3 Graph frame unit according to preset diagram pressure vs time ting at CVC 3000 mbar Torr hPa 2 Time unit gt
36. e foil from adhesive tape 1 Attach the holder for WLAN adapter in a way ME EO NG that its cable can be connected to CVC 3000 loosely and without tightening Recommended holder position for large pumping units attach holder on the rear side and for pumping units attach like in the illustrated example on the side in the rear BA N 999279 17 10 2014 vacuubrand INSTALLATION AND CONNECTION 4 Press the holder firmly on the pumping unit 5 Insert the WLAN adapter into the attached holder 4 2 Serial connection of LAN WLAN adapter CVC 3000 VARIO pumping unit PC 3001 VARIO VARIO 1 Switch off your pumping system ON OFF switch in position 0 2 Pull the CVC 3000 controller carefully out of the housing Be careful not to disconnect existing connections 3 Feed the sub D cable underneath the housing and between the pump feet to the CVC 3000 4 Connect the sub D plug of the adapter to the sub D connec tion at the rear of the CVC 3000 5 Fix the sub D plug with its screws 6 Insert the CVC 3000 controller into the housing Mi CVC 3000 prepared CVC 3000 as bench top device or for lab stand Also valid for CVC 3000 mounted directly atop pumping units 1 Switch off your CVC 3000 2 Separate the CVC 3000 from mains unplug mains plug or unplug the connection cable to the VARIO pump 3 Connect the sub D plug of the adapter to the sub D connec tion at the rear o
37. earlier than V2 00 cannot be updated for use with RC adapters Determine the firmware version loaded on CVC 3000 First turn off then turn on your CVC 3000 controller Mi The firmware version is shown for a short time on the CVC 3000 display BA N 999279 17 10 2014 vacuubrand NETWORK CONFIGURATION AND UPDATES When do I have to Not every VACUUeCONTROL update necessitates a CVC 3000 update firmware update updating 2 Depending on connection a firmware update may take up to 20 minutes N IMPORTANT Do not switch off any connected device while Updating CVC 3000 firmware Updating 4 Turn on your CVC 3000 controller with the CVC firmware VACUU CONTROL adapter connected 2 Use your web browser to navigate to the VACUUeCONTROL interface Switch to Control mode Click Quick navigation and then click CVC Firmware Enter the required password in the login window O A vl CVC Firmware Update menu opens 6 Follow the on screen instructions 1 Please download the appropriate CVC DCP 3000 Firmware from our website here 2 Please press the Browse Button and select the downloaded file Datei ausw hlen Keine ausgew hlt 3 Please press the Update Button to start the update process Update lv Update starts vi progress bar shows update status v Update is displayed on CVC display from V2 30 7 Wait for the update to terminate gt see b
38. ectrique subi m me si le brouilla ge est susceptible d en compromettre le fonctionnement BA N 999279 17 10 2014 KO APPE Serv N DIX ice range a SUPPORT Catalog Service p d Fr Seminars ni Meet the terms of 76 service Take advantage of the comprehensive service range of VACUUBRAND GMBH CO KG 9 2 Service Service in detail product guidance and practical solutions fast delivery of spare parts and accessories professional maintenance immediate repairs processing service on the spot calibration DAkkS accredited return disposal For further information visit our website www vacuubrand com 9 2 1 Terms of service service including notification of claim repair order calibration or return always requires the same steps to be taken for smooth handling gt Reduce downtime speed up the handling Keep the 1 required data and documents ready when contacting the service department Advantage Your order can be quickly and easily processed A short description or photos may help for error location Returns Process 1 Contact your local dealer or our service department 2 Request a RMA number for your order 3 Return your product including RMA number repair order short error description 1 5 Some services are not available in all areas 2 gt Tel 49 9342 808 5660 Fax 49 9342 808 5555 service vacuu
39. ential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interfer ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver s Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WLAN approval IC Canada IC This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interfer ence that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d lndustrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux condi tions suivantes 1 Vappareil ne doit pas produire de brouillage et 2 l utilisateur de Vappareil doit accepter tout brouillage radio l
40. f CVC 3000 by remote are enabled and displayed within control mode 5 2 Operating elements 5 2 1 Types of operating elements Selector switch Depending on label a selector switch changes between function or display Like a radio button only one function display is selectable Switch aspect alternates between marked selection enabled unmarked selection disabled Button An icon and or text on the button indicates the function The G buttons aspect changes when operated marked button enabled on unmarked button disabled off Radio button Auto mod Functions can be selected by radio buttons Only one function is selectable The enabled radio button is framed Program BA N 999279 17 10 2014 31 DISPLAY AND OPERATING ELEMENTS vacuubrand Quick navigation Quick navigation is a button that calls up a content list Buttons vacuubrand NG listed inside the quick navigation lead to further menus of the re mote control e g language selection network configuration up date etc gt Grayed out buttons cannot be operated They are optional N 1 or password protected Slider A slider is a control element for continuous value adjustment Click on the slider button hold and move The text box next to one slider displays the set value Additionally a tooltip on the slide button displays the adaption respectively the set value
41. f the CVC 3000 4 Fix the sub D plug with its screws 5 Reinstall the disconnected cable connections i CVC 3000 prepared 1 5 Sub D serial connection BA N 999279 17 10 2014 25 INSTALLATION AND CONNECTION vacuubrand CVC 3000 pumping unit Larger vacuum 1 Switch off your pumping system systems ON OFF switch in position 0 pumping units 2 Connect the sub D plug of the adapter to the sub D connection at the rear of the pumping unit Also valid for pumping units with an integrated controller PC 3002 VARIO PC 3003 VARIO PC 3004 VARIO PC 510 NT PC 511 NT PC 610 NT PC 6171 NT An additional RC adapter is required for PC 520 NT PC 620 NT for the second CVC 3000 3 Connect the sub D plug of a second adapter to the sub D connection at the rear of the laterally mounted CVC 3000 Example Position of sub D connections with 2x CVC 3000 4 Fix the sub D plugs with screws Mi CVC 3000 prepared or mounted CVC 3000 is located at the rear side of the pumping unit see lower circle in above figure i gt The sub D connection of a pumping unit with integrated 26 BA N 999279 17 10 2014 Function
42. he following text devices like 1 computers laptops tablets and smartphones which are typically web enabled devices are referred as end device in this manual Assembly example for VACUUeCONTROL oo Assembly example gia CVC 3000 VACUUsCONTROL LAN PC 1 CVC 3000 4 Ethernet patch cable optionally crossover adapter 2 SUB D cable NEG Serial Port Cable 3 VACUUeCONTROL 6 Monitor with user interface LAN LAN adapter VACUUeCONTROL Position 2 4 scope of supply BA N 999279 17 10 2014 19 PRODUCT DESCRIPTION vacuubrand 20 Features System compontens VACUUBRAND Product features Remote monitoring and control of pumping units or vacuum sys tems with CVC 3000 The VACUUeCONTROL application displays the user inter face through a web browser of your end device Full simultaneous operation via the CVC 3000 or by VACGUU CONTROLS remote control LAN or WLAN adapter enables the control with fixed or porta ble end devices Display and operation of VACUUeCONTROL are designed similar to CVC 3000 All commands are executed immediately Pumping units and vacuum systems which are connected to a vacuum controller CVC 3000 can easily be integrated into a computer network through LAN or WLAN adapter Multiple pumping units can be controlled or monitored from a single web enabled device Or a single pumping unit can be monito
43. ights and password management 14 2 3 Target groups eee 15 2 3 1 VACUUsCONTROL user groups 15 2 3 2 User permissions 4 A ee ee 16 2 4 Safety precautions 0 00 16 2 4 1 Personal responsibility 000 16 2 4 2 Eliminate sources of danger 17 2 5 Environmental protection 18 3 Product description 19 3 1 PUNCUONAIY oo KAG HEL EE SE EER RO TANG DNA mh nG 19 3 2 System requirements 00 000 cee ee eee 20 3 3 Components ss EE Es ee ee eee 21 3 3 1 WLAN version ss es ee se se Ee ee eee 21 3 3 2 LAN version soon ks oe EER di eee ee eee ew KE NG 22 3 4 Included materials 0 ES EE cee eee eee eee 23 4 Installation and connection 24 4 1 Holder for WLAN Adapter ss ss Es se 24 4 2 Serial connection of LAN WLAN adapter 25 4 3 Establishing initial connection 2 4 3 1 WLAN connection 0 000 ee ee eee 21 4 3 2 LAN connection aaa 28 4 3 3 Checking the connection 5005 28 4 3 4 Creating bookmarks 0000 eee eee 29 BA N 999279 17 10 2014 CONTENT 5 Display and operating elements 30 5 1 VACUUsCONTROL remote control 30 51 1 User interface EES EE SE SE SE EE Se Ee ee 30 5 1 2 Work interface 00 0 SE EE ee 31 5 2 Operating elements 0 AA
44. iginal accessories and spare parts from your spe offices and clalized distributor or through international sales offices of specialized trade VACUUBRAND GMBH CO KG gt Information about the complete product range are available in the current product catalog gt For orders questions about vacuum control and mi optimal accessories please contact your specialized distributor or an international sales office of VACUUBRAND GMBH CO KG BA N 999279 17 10 2014 23 INSTALLATION AND CONNECTION vacuubrand Web based application Adapter function Connection of CVC via sub D Example Attaching holder to 24 PC 3001 VARIO 4 Installation and connection VACUU CONTROL is a web based remote control displayed in a web browser No installation via data medium is required The adapter contains the complete software required to display the VACUU CONTROL remote control on your end device VACUU CONTROL WLAN or VACUU CONTROL LAN are con nected directly to the sub D connection of your CVC 3000 Connection to the CVC 3000 controller can be made in any of several ways depending upon the design configuration of your pumping unit 4 1 Holder for WLAN Adapter Attaching holder for WLAN adapter 1 Remove protective foil from one side of the adhesive tape 2 Attach the adhesive tape centered on the rear side of the holder 3 Remove the second protectiv
45. k configura UPON access tion not known v Read instruction for use of gt SUB D plug loose network router network con Distance between WLAN nection or end device adapter and end device is Check SUB D connection too far and fix gt Structural restrictions rein Reduce distance to WLAN forced concrete steel beams adapter water etc v In case of larger distances or structural interferences use a WLAN router to integrate the WLAN adapter into your net work v Use repeater or v use LAN Adapter v If indicated reset to factory settings WLAN network is gt WLAN adapter not correctly Check plug connection Admin not displayed connected Check name of WLAN net gt VACUU CONTROL WLAN work network uses the same SSID NA Replace defective parts as another network gt WLAN adapter defective SSID has been changed gt WLAN adapter has been integrated into an existing network infrastructure No connection to CVC 3000 or pumping sys v Switch on CVC 3000 or Control adapter tem switched off pumping system Admin gt SUB D plug loose v Check SUB D connection v Fix SUB D connection BA N 999279 17 10 2014 69 RESOLVING PROBLEMS Fault gt Cause v Remedy Personnel No connection to gt Ethernet cable LAN not v Check for connection icon in Admin adapter plugged in correctly CVC 3000 display Cable break v Check patch cable
46. mic IP address Off use fixed IP address IP address of VACUU CONTROL Factory setting 192 168 1 111 Mask to distinguish between internal and exter nal addresses Gateway for connections from subnets Name service not used Device name as alternative to IP address of re mote control Factory setting VACUUCONTROL Display title for browser tab and bookmarks or shortcuts MAC address of adapter information for net work administration not editable BA N 999279 17 10 2014 vacuubrand NETWORK CONFIGURATION AND UPDATES 7 1 2 Password management NOTICE Pay attention to password protection in condition at delivery In condition at delivery only the admin area Network configuration amp updates is password protected The access to View and Control is open to enable a quick use of the web based remote control 2 Protect your system by assigning passwords gt Change the password for the admin area Admin immediately after initial login Passwords can be between 1 and 19 characters Each user group e g View or Control can be assigned one password IMPORTANT Empty text boxes indicate that no password protection applies i e no password protection Changing editing passwords 1 Access the network configuration menu 2 For example click on the text box Password Admin Password Admin admin oy Password Control i Password View 3 Delete the e
47. n min Delay min Low fast large amounts of solvents Normal normal High slow small amounts for solvents with tendency to foam For VARIO pumps Motor speed parameter for pump down For CVC 3000 Detect Hysteresis parameter Adjustment range 1 101 101 HI mode For VARIO pumps only Vacuum setting Once reached controller switches off the VARIO pump Adjustment range 0 1 1060 O OFF Process runtime Measured from when user presses Start button Pump stops when Duration has been reached Adjustment range O 1440 O OFF Delay time for an optional coolant valve Coolant valve is closed after Delay time has been reached HI mode optimum speed for the respective pressure recommended setting 50 BA N 999279 17 10 2014 OPERATION Parameter Program Menu 787 mbar control parameter SAG df Program Current program Edit load from prog 19 Q Load Save as prog 1Q Save Meaning Parameter Meaning Current program Edit program up to 10 programs are storable for CVC 3000 load from prog Load the selected program Save as prog Save the program under the selected number Parameter VACUU LAN Menu 787 mbar control parameter AE AN sd VACUUsLAN Set vacuum mbar 2 Switch on mbar 170 a Delay min 43 mt Meaning Parameter Meaning Set vacuum Adjustment of the vacuum set point mbar Adjustment range 1 1060 Switch on
48. n our web page www vacuubrand com s Contact us regarding any questions about this product if you need further information or to provide us with feedback s When contacting our Customer Service Department please be sure to have the software version number of your CVC 3000 and of the VACUU CONTROLS application s On reguest you will receive barrier free instructions for use e g with larger type characters 1 2 About this document 1 2 1 Symbols and icons Warning symbol Prohibition symbol Mandatory action symbol Process running please wait Positive example Do Negative example Do not BA N 999279 17 10 2014 vacuubrand INTRODUCTION Additional icons Refers to content of this document Z Refers to content of other documents 1 2 2 Display conventions Warning levels Convention for BINNA warnings g Indicates an imminent hazardous situation Disregarding the situation will result in serious and even fatal injury or death 2 Take appropriate action to avoid dangerous situation Indicates a potentially hazardous situation Disregarding the situation could result in serious even fatal injury or massive damage to property gt Observe instruction to avoid dangerous situation Indicates a potentially hazardous situation Disregarding the situation could result in slight or minor injury or damage to property gt Observe instruction to avoid dangerous situation NO
49. nabled or disabled IMPORTANT gt Pay attention to safety standards prevent improper use of remote control by password assignment 2 Use secure passwords and keep them safe Access rights for target groups Password Admin J Password Control Password View Target group Access permission Admin Administrative permission full access for using view mode control mode network configuration password assignment updates Control Read write permission enabled for using view mode control mode View Read permission gt enabled for using View mode BA N 999279 17 10 2014 vacuubrand SAFETY INSTRUCTIONS 2 3 Target groups Users and target groups for using VACUU CONTROLS are de fined by access permission within password management 2 3 1 VACUU CONTROL user groups View Required Personnel with permission to use the VACUUeCONTROL ap qualification plication in VIEW mode can monitor but not control the pumping for user ol unit Users must have been instructed about potential risks which VACUU CONTROL may occur from incorrect behavior or improper use Control Qualified and skilled personnel with permission to use the VACUUeCONTROL application in CONTROL mode They can monitor and control the pumping unit including adjustment of pa rameters suchas vacuum level modeofpumping unitoperation etc Users are responsible for their actions in control mode Admin Per
50. ns remote control is only possible with adapter A bookmark is a Uniform Resource Identifier URI that is stored for later retrieval for quick access to a website Depending on the used browser bookmarks are also called favorites or internet shortcuts Or Ethernet cable Cable type of network technology and telecommunications such as Ethernet networks Key combination on a smartphone to set a linked icon on the homescreen for easy access to the application just like a bookmark For how to create shortcuts read user manual of your smartphone Any application software firmware that is displayed on a web browser or is created in a browser supported pro gramming language web based Displays the graphical user interface of web applica tions or web based software BA N 999279 17 10 2014 9 4 Index A Abbreviations 10 Access rights 14 active log off Adapter function 24 Additional icons 8 9 Admin a 15 Assembly example 19 B bargraphic 34 ButtonS si gee a be ae 31 C Changing editing password 61 Checking the connection 28 Components 21 COMIACEs ta SERE RE Me aes 8 Control control mode 31 Control element 33 Convention for warnings 9 Copyright 8 Creating bookmarks 29 CVC 3000 10 62 D Data logger 54 DGP 3
51. nto the address bar of your web browser If the VACUU CONTROL user interface on your web browser matches to the connected CVC 3000 the connection has been correctly established BA N 999279 17 10 2014 Open default view Example IP address factory setting Example Bookmark on web browser Example device name d m LABI VACUUCONTROL x e gt C NIN 19216 INSTALLATION AND CONNECTION Open default view 1 Start the web browser of your end device 2 In case of initial connection enter the factory set IP address into the address bar 192 168 1 111 or VACUUCONTROL GEvacuucontroL x pa C A 1192 168 1 111 Apps C Vakuumpumpe fur we Or 3 Ask your system administrator for an assigned IP address and enter that address 4 Confirm your input with the Enter key M VACUU CONTROL is displayed 4 3 4 Creating bookmarks Bookmark the website or save as favorite or shortcut to gain quick access to VACUU CONTROL Refer to the help function of your web browser for informa tion on how to create bookmarks favorites or shortcuts for links and preferred websites 2 Ask your IT department or Admin to create appropriate device names inside network configuration if the remote control has been integrated into a network see chapter 7 Network configuration and updates The device name will then be used
52. of gt WLAN signal impaired by v Do not place WLAN adapter Admin range interfering signals in the vicinity of sources of b Distance between WLAN electro magnetic interference adapter and end device is v In case of larger distances too far use a WLAN router to inte grate the WLAN adapter into your network 68 BA N 999279 17 10 2014 RESOLVING PROBLEMS Fault Cause v Remedy Personnel Frequent network gt Interference v Do not place WLAN adapter Admin or connection b Signal is impaired by other in the vicinity of other radio losses radio technology e g Blue technology tooth microwave oven Do not place WLAN adapter gt Interfering signals e g from in the vicinity of jammers transmission mast magnet v Reduce distance to WLAN or foreign network adapter Distance between WLAN V adapter and end device is v Check if your end device is too far still connected to the VACU End device has connec UCONTROL SoftAP ted automatically to another Disconnect preferred wirel stronger or preferred wireless ess network connections network v Select and connect VACUU CONTROL again v Select VACUUCONTROL and start connecting again No WLAN connec gt CVC 3000 or pumping sys v Switch on CVC 3000 or Admin tion tem switched off pumping system gt Another user is already con v Check if another user is Authentication nected to the SoftAP already logged in Agree error gt Options of networ
53. played gt JavaScript is blocked web browser Admin v Allow JavaScript IP address has Connection has been inter v Check connection Control been entered but rupted v Reload or refresh page Admin user interface is gt Enter key has not been not displayed pressed gt IP address has been changed in network configu ration CVC 3000 does not gt Firmware update has failed v Repeat CVC firmware update Admin start gt Update has been interrupted Or v contact our Service Several CVCs gt Device names still set to fac v Call up the network configu Admin have been equipped with VACUUeCONTROL all are named VACUUCONTROL tory settings VACUUCONTROL Device names have not been changed in the network con figuration ration menu switch on the devices one after another assign different device names in the network config uration e g LAB Z1 LAB X2 etc 70 BA N 999279 17 10 2014 Fault Cause RESOLVING PROBLEMS v Remedy Personnel Measured values are only displayed in the web browser window not down loaded gt Browser dependent v Use a different web browser for downloading e g Firefox or Internet Explorer 10 or v select save as in your web browser Control Admin No GUI update gt Firmware of an adapter has v Use the direct link IP Admin possible via quick been updated Address admin webLocal navigation g
54. r with opera tional status information The data are continuously written into a memory store of the RC adapter The memory can store up to 200 000 data points This data stor age is overwritten on a rolling basis Due to the local storage a high data security is given Data stored by the data logger will be deleted when the CVC 3000 and remote control adapter are disconnected during software updates or when the CVC 3000 is turned off IMPORTANT The desired time interval for recording needs to be adjusted before running the process Interval sec 1 60 Open menu Data logger Click on the Data logger button v Button marked v Data logger menu is displayed BA N 999279 17 10 2014 OPERATION Menu Data logger View data logger Data logger menu Select data All measured data Download S Decimal mark m ES Interval sec 1 WOS 60 6 O Cancel OK Meaning 1 Title bar with menu name 2 Drop down list Select time period of recorded data 3 Button Start download 4 Selector switch Preset decimal separator point comma 5 Selector switch Preset time interval 1 10 60 second s default 10 seconds Download process data IMPORTANT The download of process data can last up to 10 minutes All measured data 1 Select the measurement starting time from drop down list Download B Shr vi Measured datat are downloaded a
55. red from several end devices Documents processes via the integrated data logging function Process data can be downloaded through the VACUU CONTROLS application The application also notifies users of process completion by a signal s System protection by password management Available as an add on for all CVC 3000 vacuum controllers using software version 2 0 and higher 3 2 System requirements VACUUBRAND Version CVC 3000 Version 2 0 or higher update to 2 3 VACUUeCONTROL LAN WLAN V1 00 VAGUU CONTROL GUI V1 00 BA N 999279 17 10 2014 vacuubrand PRODUCT DESCRIPTION Recommended Web browser provided by customer Version web browser Android gt 2 3 x capable of iOS Safari gt iOS 5 1 HTMLS Safari gt 5 Google Chrome gt 32 Internet Explorer gt IE9 Mozilla Firefox gt 17 Opera gt 2 Javascript activated 3 3 Components Listed below is all the hardware needed for operating the VACUU CONTROLS on your end device 3 3 1 WLAN version Hardware CVC 3000 vacuum controller or pumping unit with CVC 3000 components E WLAN version VACUU CONTROL WLAN RC adapter WLAN end device including web browser recommended WLAN capable router or Access Point Assembly with WLAN adapter WLAN router Example assembly K BA N 999279 17 10 2014 21 PRODUCT DESCRIPTION vacuubrand gt Integrate VACUUeCONTROL WLAN with a WLAN H capable router or Acces
56. s csv file T M csv file stored in local folder e g in folder Download vi or spreadsheet opens directly All measured data 2014 06 02 08 49 36 2014 06 02 09 06 40 2014 06 02 09 07 03 2 Determine the required decimal separation for correct dis play of pressure value M Button marked 3 Click on button Download 4 gt The maximum number of data points stored is 200 000 If you attempt to store more than 200 000 data points the oldest data will be overwritten BA N 999279 17 10 2014 55 OPERATION Display downloaded data y EH Logger 10 ccv Open the downloaded csv file with a spreadsheet Mi Spreadsheet starts up vi documented data are displayed Spreadsheet with documented data Example ima PD n PEE A B documented C D 1 25 03 2014 18 16 mbar Mode 0 VACUU LAN 1 Pumpdown 2 Control 3 Automatic 4 Program Start 0 Stop 1 Start process data 2 0 728 4 0 3 10 728 5 1 0 4 20 729 1 0 5 30 729 2 1 0 6 40 729 5 1 0 7 50 729 9 1 0 8 60 730 1 0 9 70 730 3 1 0 10 80 730 5 1 0 11 90 730 7 1 0 12 100 731 1 1 0 13 110 731 2 1 0 120 731 5 1 0 15 130 731 7 1 0 16 140 7322 1 n Meaning 1 Date Time starting time process time sec table columns 2 Pressure values according to default setting mbar Torr hPa 3 Operation mode Mode 2 Vac control gt 0 VACUU LAN gt 3 Auto mode gt 1 Pump down gt 4 Program 4 St
57. s Point into your PC network It allows access for various end devices 3 3 2 LAN version Hardware CVC 3000 vacuum controller or vacuum system with components CVC 3000 AN version VACUUsCONTROL LAN RC adapter LAN end device including web browser one free ethernet connection recommended LAN router or LAN switch Assembly with LAN adapter LAN switch computers Example assembly 1 5 use crossover adapter for computer without Gbit s ethernet standard 22 BA N 999279 17 10 2014 vacuubrand PRODUCT DESCRIPTION 3 4 Included materials Scope of supply Web based remote control WLAN version WLAN version WACUU CONTROL WLAN RC adapter 683110 Holder adhesive tape 635631 Instructions for use DCP 3000 999283 Instructions for use CVC 3000 999279 or Scope of supply Web based remote control LAN version LAN version VACUU CONTROLS LAN RC adapter 683120 Cable Sub D 9 pol Bu Bu 1 1 1 8 m serial cable 612748 Patch cable Cat 5e 2 m bl Ethernet cable Crossover adapter RJ45 Bu S Instructions for use DCP 3000 999283 Instructions for use CVC 3000 999279 e gt The description of the scope of supply refers to the 1 product you have purchased either WLAN or LAN intended for a better understanding gt Illustrations and drawings of additional hardware are solely Source of supply International sales Purchase or
58. sonnel with permission to use the VACUU CONTROL ap plication in ADMIN mode have full control over the pumping unit and the VACUU CONTROL application including setting access rights for other users IMPORTANT Users need to have the corresponding skills and qualifications for doing the job listed in the table User permissions BA N 999279 17 10 2014 15 SAFETY INSTRUCTIONS vacuubrand User group capabilities Quality standards and safety Qualification and personal responsibility 2 3 2 User permissions Job Function View Control Admin Select language X X Reporting malfunction X View mode monitoring via remote X Control mode control via remote Assembly LAN WLAN adapter Connecting VACUUsCONTROL Monitoring system and process Network integration Network settings Password management Rights management Updates Reset to factory settings gt lt x XK XK XK XK X X xXx XK KR KO KR DE O KK OK DE DE 2 4 Safety precautions Products of VACUUBRAND GMBH CO KG are subject to high quality tests with goals for safety and operation Prior to delivery each product has been tested thoroughly Nevertheless during operation unforeseen dangerous situations may occur which may lead to injuries or damage of property Therefore observe the following chapter and take the appropri ate safety precautions 2 4 1 Personal responsibility Ensure that the VACUU CONTROLS application is only operated b
59. t The current GUI does not html to update the GUI soft match the firmware update ware A message recommending a v Reload page after update GUI update appears v Contact our Service No internet con gt WLAN adapter configured as v Integrate WLAN adapter via Control nection SoftAP or WLAN router into your net Admin gt computer connected directly Work to LAN adapter v Use mobile data connection via your SIM card to connect to the internet Connection loss is Network error v Remove network error Control displayed gt Web browser overloaded v Reload page Admin gt Controller or vacuum system v Switch on controller or vac switched off uum system again Cable removed from adapter Check cables and connec gt Cable defective or loose con tions tact at connector v Replace defective parts gt Adapter has been removed v Remote control requires a b More than X users are connected adapter for opera already accessing the tion reconnect adapter VACUUCONTROL remote control Language changes gt With each website relaod the v Reselect required language View automatically language switches to the one Control that is preset on the connec Admin ted CVC 3000 Storing cookies to fix lan guage selection is not possi ble with WLAN LAN adapter v i The troubleshooting table Fault Cause Remedy will help you identify and correct the most common errors gt
60. t box ready for input m unframed info display 2 5 Tooltips do not appear on mobile devices BA N 999279 17 10 2014 37 OPERATION 6 Operation The VACUU CONTROLS application uses a web browser on your web enabled end device to show synchronized data from your CVC 3000 vacuum controller Knowledge of the function and operation of the CVC 3000 are basic requirements for using the VACUU CONTROLS application and hardware to control the CVC 3000 remotely IMPORTANT Read instructions for use of the CVC 3000 or your pumping system before using remote control 6 1 Starting VACUU CONTROLS application Open default view 1 Start the web browser of your end device 2 Enter the IP address into the address bar of your web browser gt Example EE VACUUCONTROL x Enter U IP address fz CG 11192 168 1 111 Apps lt Vakuumpumpe f r Ng 3 Confirm your input with the Enter key M VACUU CONTROL is displayed Or Open up by bookmark 1 Start the web browser of your end device f 2 Click on the bookmark of the controller you want to monitor Fa control by remote control saad also see chapter 4 3 4 Creating bookmarks M VACUU CONTROL is displayed 1 5 Ask your system administrator for an assigned IP address or enter the facto ry set IP address 192 168 1 111 or enter the device name VACUUCONTROL 38 BA N 999279 17 10 2014
61. tAP Soft Access Point WLAN adapter acts as direct access point for WLAN WIFi devices BA N 999279 17 10 2014 2 INSTALLATION AND CONNECTION vacuubrand Function LAN adapter 28 4 3 2 LAN connection The VACUU CONTROL LAN adapter is the remote interface by cable to your CVC 3000 As delivered the LAN adapter acts as DHCP server and client The LAN adapter can be connected directly to a computer or it can be integrated into a network For integrating the adapter into a network we recommend the use of a LAN switch or a LAN router see chapter 7 Network con figuration and updates IMPORTANT In case of integration into a server your system administrator has to provide a free IP address Establishing LAN connection 1 Plug one end of the network cable patch cable into port at LAN adapter 2 Plug the other end of the network cable into Ethernet port of your computer router or switch v Device connected to LAN adapter gt Use the enclosed crossover adapter if connecting directly 1 to a computer without Gigabit Ethernet connection which doesn t support auto crossover gt As delivered a DHCP server is active The directly connected computer automatically obtains a valid IP address Changing the network settings disables the DHCP server 4 3 3 Checking the connection To verify that your LAN or WLAN adapter has been properly con nected enter the IP address i
62. tion by remote control with colleagues gt Set up password protection see chapter 7 1 2 Password management Remonte control In addition to the status display the control elements are enabled Control mode for operating by remote control Control mode This means you have direct access to the vacuum system Mode Control is intended for personnel with read write permis sion Switch to control mode Click on selector switch Control on the upper left side vi Selector switch Control is marked M Display with current pressure appears 2 Ask your system administrator for the password if an access window appears BA N 999279 17 10 2014 43 OPERATION 6 4 1 Display pressure reading Once VACUU CONTROL is opened via web browser the mea sured pressure of the vacuum controller CVC 3000 will be dis played This applies to both modes view mode and control mode In control mode additional control elements are enabled View current pressure reading ad Example o eo Pump down Qonida Pressure reading CVC 3000 and VACUU CONTROLS in Control mode 9 Mode Vent Start He Meaning 1 VAC 4 Numerical value gt Vacuum gt current pressure 2 Bargraph 5 ATM graphical element for atmospheric pressure pressure reading 3 Pressure 6 Enabled control elements unit according to preset ting at CVC 3000 mbar Torr hPa 44 BA N 999279 17 10
63. tion causes connectivity problems between the VACUU CONTROL adapter and your end device gt Do not change network configuration parameters Seek help from a network administrator gt Do not change network settings during operation Connection loss during update Remote process control is not possible while updating gt Never perform an update while operating your pump Malfunction failure of remote control or CVC 3000 Interrupting an update e g by aborting the update or by starting the same update from different end devices may cause failure of the remote control or of your CVC 3000 gt Never attempt to update the CVC 3000 from multiple web enabled devices at the same time gt Always wait until the update has been completed Network configuration and updates are assigned to the Ad min user providing unrestricted access to VACUU CONTROLS remote control For initial login the password is factory set to admin After log ging in using the default password the Administrator should change the password Username Password Log in Cancel N IMPORTANT Protect Network configuration and Update from unauthorized access 2 Change password immediately after initial login BA N 999279 17 10 2014 Network configuration menu WLAN factory settings NETWORK CONFIGURATION AND UPDATES 1 1 Network configuration Use the Network configuration menu to integrate
64. ture gt If necessary vent with inert gas max 1 2 bar abs IMPORTANT Certain process may cause pressure to build Up The Vent button is used to vent the system A short click on this Vent button will momentarily vent the system as the process contin ues Holding the vent button for longer than 2 seconds will cause the system to be vented to atmospheric pressure and the pump will stop running Momentarily ventin Vent Click on the Vent button less than 2 seconds a Button momentarily marked M venting impulse venting valve opens momentarily short term pressure increase Continuous venting Vent 2 Click on the Vent button longer than 2 seconds am lV Button is marked as long as pressed symbol for venting valve is blinking v venting valve open gt continuous pressure increase until atmospheric pressure gt When atmospheric pressure is reached the venting valve 1 closes automatically BA N 999279 17 10 2014 53 OPERATION Memory capacity Delete data LB y by N Fe a N I 54 Stop venting Click on the Vent button or on Start Button unmarked M Venting has stopped venting valve closes 6 4 7 Download process data Data logger The VACUUeCONTROL application has a built in data logger function As long as the CVC 3000 is powered on pressure time data will be stored at adjustable intervals togethe
65. uipment Avoid hazardous situations which arise from different settings DANGER Explosion hazard for critical processes operated by remote control Depending on the process explosive mixtures can develop 2 Never operate critical processes by remote control Depending on the running process explosive mixtures can form in plants or other hazardous situations could result BA N 999279 17 10 2014 17 SAFETY INSTRUCTIONS vacuubrand Log off Exposure to WLAN radiation Observe environ mental regulation 18 Once logged in password is activated until the web browser is closed For user with access permission for VACUU CONTROLS we recommend the active log off Close web browser window for active log off Place the wireless adapter so that the minimum distance to indi viduals during operation is at least 20 cm 2 5 Environmental protection Observe the national and international environmental regulations for disposal of your product as well as spare parts This is espe cially valid for all components that are contaminated with hazard ous substances BA N 999279 17 10 2014 vacuubrand PRODUCT DESCRIPTION 3 Product description 3 1 Functionality Functional VAGUU CONTROL is a web based application to operate your principle vacuum system with CVC 3000 by remote control Monitoring and control take place on the web browser of your smartphone tablet or computer To simplify descriptions in t
66. xisting password 4 Enter the new password via keyboard 1 19 characters v Entry is shown in clear text 5 Confirm input with OK New changed password for Admin has been saved Go 1 BA N 999279 17 10 2014 61 NETWORK CONFIGURATION AND UPDATES vacuubrand Updates File extension update files Required CVC firmware O 3000 vacuubrand a 62 7 2 Updates The update is split into several steps i e into separate submenus see separate buttons in Quick navigation Update An authentication as admin is required to execute updates IMPORTANT Required updates must be carried out in the following order 1 CVC 3000 firmware 2 VACUUsCONTROL LAN WLAN RC adapter firmware 3 VACUUeCONTROL GUI user interface in your web browser The required update files are provided online on our website Download Correlations between file extensions and update files File extension For update of dat CVC 3000 firmware da2 VACUU CONTROLS LAN firmware da2 VACUUeCONTROL WLAN firmware daa VACUUeCONTROL GUI user interface 7 2 1 CVC 3000 In order to use the VACUU CONTROL application your CVC 3000 requires firmware version V2 30 or higher For CVC 3000 controllers with firmware versions between V2 00 and V2 29 a firmware update is needed before establishing the initial connection IMPORTANT CVC 3000 controllers with firmware versions
67. y authorized and skilled personnel This is particularly impor tant with regard to connecting the VACUU CONTROLS adapter to the pump operating the VACUUeCONTROL application or the pump and troubleshooting 2 Carefully read these instructions for use before using the remote control 2 Use the remote control only if you have understood its func tion and these instructions for use BA N 999279 17 10 2014 Oualification and personal responsibility Safe work Use only in proper working condition Regard network safety standards Organize usage of remote control Explosion danger for critical processes SAFETY INSTRUCTIONS Personal safety has top priority Processes which create a poten tially hazardous situation must not be operated unsupervised by remote control Always be conscious of safety and work in a safe manner Observe the owners directives at work the national accident pre vention regulations and occupational safety provisions 2 4 2 Eliminate sources of danger Only use the vacuum system when it is in proper working condition Change the Admin password directly after initial connection As sign passwords for Control and View The system can be simultaneously controlled by a local CVC 3000 vacuum controller or by a remote control A remote control can be configured to control multiple pumping units si multaneously Coordinate planned projects with colleagues that share this eq
Download Pdf Manuals
Related Search
Related Contents
Print - Dialogic User`s manual “VENTS domestic fans” ( PDF 424,91Kb ) DT-950 Drum Trainer Rhythm Coach Bedienungsanleitung NetWinder OfficeServer User`s Guide INAP375T Datasheet Genie S_40 Product Specifications FT-GELSSON.FR rev.0 3 PHASE DIGITAL POWER CLAMP METER Technical Service Manual Copyright © All rights reserved.
Failed to retrieve file