1. Ozone Systems Installation amp Maintenance Manual PRO 10 PRO 12 PRO 14 Recirculation System Timed recirculation system for use with ozone generator on water storage tanks ClearWater Tech LLC Integrated zone Systems 850 E Capitolio Way San Luis Obispo Ca 93401 805 549 9724 Fax 805 549 0306 E mail service cwtozone com www cwtozone com Copyright 2003 ClearWater Tech LLC Reproduction of any kind is prohibited LIT620 REV092807 INTRODUCTION The PRO 10 PRO 12 PRO 14 is a recirculation system kit for use with ClearWater Tech ozone generators in the 0 25 to 8 0 grams per hour range It consists of a pump with an injector check valve assembly attached and a timer controller RECOMMENDED SIZING For one or more tanks totaling up to 300 gallons use a ClearWater Tech S 1200 ultraviolet ozone generator For one or more tanks totaling up to 600 gallons use a ClearWater Tech CS 1400 ultraviolet ozone generator For one or more tanks totaling up to 900 gallons use a ClearWater Tech CD10 AD corona discharge ozone generator Larger generators are available THE PRO 10 PRO 12 PRO 14 KIT The PRO 10 PRO 12 PRO 14 kit consists of the following components 1 1 l 20 4 4 PRO 10 120 VAC 60 Hz PRO 12 240 VAC 50 Hz or PRO 14 240 VAC 60 Hz unit Kynar check valve assembly with ozone inlet fitting 1 4 barb fitting for ultraviolet ozone generators or 1 4 O D Kynar compression fitting
2. must be returned to CWT and must include the following information e End user name e Complete address including telephone number e Date installed e Complete model and serial number information e Name of company from which the unit was purchased Repairs and replacement parts provided under this warranty shall carry only the unexpired portion of this warranty or 90 days whichever is longer Items Excluded from the Warranty This warranty does not extend to any product and or part from which the factory assigned serial number has been removed or which has been damaged or rendered defective as a result of e An accident misuse alteration or abuse e An act of God such as flood earthquake hurricane lightning or other disaster resulting only from the forces of nature e Normal wear and tear e Operation outside the usage parameters stated in the product user s manual Check valve solenoid valve failure e Use of parts not sold by CWT e Damage which may occur during shipping e Service or unit modification not authorized by CWT e Failure to meet service requirements as outlined in the I amp O manual Obtaining Service Under the Warranty Any product and or part not performing satisfactorily may be returned to CWT for evaluation A Return Goods Authorization RGA number must first be obtained by either calling or writing your local authorized dealer distributor or CWT direct prior to shipping the product The problem experienced with the produ
3. Ultraviolet ozone generator into convenience socket on PRO 10 12 14 ClearWater Tech PRO 10 12 14 Connect PRO 10 12 14 and ClearWater Tech CD10 AD corona discharge ozone generator to continuously powered electrical source of correct voltage Hz ELECTRICAL CONNECTIONS WITH CD10 AD CORONA DISCHARGE OZONE GENERATOR a ee sus j ClearWater Tech CD10 AD corona discharge ozone generator Signal from CD10 AD external control loop to PRO 10 12 14 external control loop receptacle Connect PRO 10 12 14 and ClearWater Tech CD10 AD A corona discharge ozone ClearWater Tech generator to continually PRO 10 12 14 powered electrical source of correct voltage Hz ClearWater Tech LLC Limited One Year Warranty Summary of the Warranty ClearWater Tech LLC CWT makes every effort to assure that its products meet high quality and durability standards and warrants the products it manufactures against defects in materials and workmanship for a period of one 1 year commencing on the date of original shipment from CWT with the following exceptions 1 The war ranty period shall begin on the installation date if the installation is performed within 90 days of the original shipment from CWT 2 The warranty period shall begin on the date of the bill of sale to the end user if the installation date is more 90 days after the original shipment date To validate the warranty a warranty card accompanied by acopy of the bill of sale
4. then the MINUTE key to select the desired first ON time Press TIMER key once Display will show 1 OFF Repeat previous step to select the desired first OFF time Repeat the entire sequence to complete up to eight ON OFF times as desired When programming is done press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word AUTO To Review Program Press TIMER key repeatedly When done press the CLOCK key to return to the time of day To Cancel Change Part of the Program Press TIMER key repeatedly until the particular ON or OFF time appears Set new ON or OFF time See to set programs To Override Automatic Operation Press SELECT key to move indicator bar to the desired ON or OFF position Note Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO To Override Timer Status On or OFF Press OVR key Timer will resume automatic operation with the next opposite set point JINTERMatic ClearWater Tech CD10 AD corona discharge ozone generator NOTE C10 AD is supplied with 1 4 Teflon ozone supply tubing while the ultraviolet ozone generators are supplied with 1 4 braided tubing Connect ozone supply tubing from ozone generator to PRO 10 PRO 12 Ozone ClearWater Tech PRO 10 12 14 ELECTRICAL CONNECTIONS WITH ULTRAVIOLET OZONE GENERATOR ClearWater Tech Ultraviolet Ozone Generator Plug ClearWater Tech
5. T ozone generator plug the power cord from the ozone generator into the convenience socket on the PRO unit If you are using a Clear Water Tech CD10 AD M 15 AD or CD15 AD CORONA DISCHARGE ozone generator it must be plugged into a continuously powered electrical source as the air dryer in the unit must run at all times If a CD10 AD M 15 AD or CD15 AD ozone generator is being used connect the external control loop connecting wire between the external control loop receptacles on the ozone generator and the PRO unit 24 hour digital timer Display 120 VAC switched Reset port to cancel Receptacle all prior settings Bonding Lug External Control Loop Receptacle ON AUTO OFF select Key IEC Standard Power Cord Receptacle Function Keys Ozone Inlet Fitting Ozone Inlet Kynaro 7 p m 7 a Check Valve Indicator LED ON when connected to power source and contracts are closed Noryle Magnetic Drive Circulator i al High Efficiency Venturi Injector 3 4 D Hose x 3 4 MPT Connections INSTALLATION PROGRAMMING INSTRUCTIONS To Set or Change the Time To clear entire memory press reset key Hold down the CLOCK key while pressing either the HOUR or MINUTE keys Continue pressing until the desired number is shown Then simply lift finger off the CLOCK key to set To Set program On Off Times Press TIMER key once to enter into program mode Display will show 1 ON Press the HOUR key and
6. ct and or part must be clearly described The RGA number must appear prominently on the exterior of the shipped box es The product and or part must be packaged either in its original packing material or in comparable and suitable packing material if the original is not available You are responsible for paying shipping charges to CWT and for any damages to the product and or part that may occur during shipment It is recommended that you insure the shipment for the amount you originally paid for the product and or part If after the product and or part is returned prepaid and evaluated by CWT it proves to be defective while under warranty CWT will at its election either repair or re place the defective product and or part and will return ship at lowest cost transportation prepaid to you except for shipments going outside the 50 states of the United States of America If upon inspection it is determined that there is no defect or that the damage to the product and or part resulted from causes not within the scope of this limited warranty then you must bear the cost of repair or replacement of damaged product and or part and all return freight charges Any unauthorized attempt by the end user to repair CWT manufactured products without prior permission shall void any and all warranties For service contact your authorized dealer or distributor or CWT direct at 805 549 9724 extension 27 Exclusive Warranty There is no other expressed warranty on CWT pr
7. for CD10 AD corona discharge ozone generator IEC standard power cord 120 VAC NEMA or selection of 240 VAC 50 Hz configurations are available 3 4 I D braided PVC tubing 3 4 tubing nipple x 3 4 male thread fittings for tubing two are installed on PRO 10 PRO 15 Hose clamps for above fittings When opening the package check to make sure all of the above components are included Do not throw away any packaging until all components are found in case some have become hidden in the packing materials INSTALLATION 1 Securely mount the PRO unit and the ozone generator adjacent to each other on a sheltered surface within 5 of the tank s if possible below the normal median water level no higher than 3 from the bottom of the tank s 2 Install the supplied ozone check valve ozone inlet fitting assembly into the injector on the PRO unit as shown in the 1l lustration below Connect the ozone supply tubing from the ozone generator to this ozone inlet fitting on the PRO unit 3 Using Teflon tape on the threads install the other two 3 4 tubing nipple x 3 4 male thread fittings into the inlet and outlet fittings on the water tank 4 Cut the 3 4 tubing supplied with the PRO unit to fit between the unit and the tank as shown in the illustration below Install with the supplied hose clamps on all four ends to secure tubing 2 Refer to the illustrations on the following pages If you are using a ClearWater Tech ULTRAVIOLE
8. oducts and or parts Neither this warranty or any other warranty expressed or implied including any implied warran ties or merchantability of fitness shall extend beyond the warranty period Some states do not allow limitations on how long an implied warranty lasts so that the above limitation or exclusion may not apply to you Disclaimer of Incidental and Consequential Damages No responsibility is assumed for any incidental or consequential damages this includes any damage to another product or products resulting from such a defect Some states do not allow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may not apply to you Legal Remedies of Purchaser This warranty gives you specific legal rights and you may also have other rights which vary from state to state THIS STATEMENT OF WARRANTY SUPERSEDES ALL OTHERS PROVIDED TO YOU AT ANY PRIOR TIME ClearWater Tech LLC 850 Capitolio Way Suite E San Luis Obispo California 93401 Phone 805 549 9724 Fax 805 549 0306
Download Pdf Manuals
Related Search
Related Contents
File - metroSolarMatics SOLDES SUR ALM : MODE D`EMPLOI Model 1310 TraxleTM and In/Out Application User`s Manual Fujifilm Pro 160 S 135/36 GridLink Configuration Software for the GridBoss System User Manual COMPACTPCI-817 PERIPHERAL BOARD USER`S MANUAL Philips LivingColors Table lamp 70999/60/PH Frame Grabber Integration Programmer`s Manual Integral FC1 mobile - Funkwerk Security Communications Copyright © All rights reserved.