Home

EMULEX - The UK Mirror Service

image

Contents

1. California 92626 VD9950902 Rev C 714 662 5600 TWX 910 595 2521 April 1986 Copyright C 1985 Emulex Corporation The information in this manual is for information purposes and is subject to change without notice Emul ex Corporation assumes no responsibility for any errors that may appear in the manual Printed in U S A This software distribution kit contains the following media Emul ex Part Number Description VD9960703 5 25 inch floppy for MicroVAX VD9962003 TK50 cartridge for MicroVAX This kit contains the following User s Manuals to document the programs contained on the distribution media Emul ex Part Number Description MicroVAX Driver Distribution Kit Cover VD9951903 VD9950902 MicroVMS TS11 Software Driver Installation Guide BLANK Section 1 GENERAL DESCRIPTION 1 1 INTRODUCTION This manual is a guide to installation of the MicroVMS TSIL software driver TSDRIVER on Digital Eguipment Corporation DEC MicroVAX I and II computers The document contains two main sections s General a L0A This section contains an overview of TSDRIVER o Installation This section presents oh ration instructions for TSDRIVER There are no operating instructions because TSDRIVER requires no user interaction once installed 1 2 PRODUCT OVERVIEW As written by DEC the MicroVMS operating system does not support TSll type devices TSDRIVER is a software driver that provides
2. TS11 support under MicroVMS 4 n The TSll type device at the standard TSSR and vector address is designated as MSAO by MicroVMS Alternate TSSR and vector addresses can also be selected see the appropriate tape coupler technical manual for details 1 3 DISTRIBUTION MEDIA The following table lists TSDRIVER distribution media Emulex P N Description VD9960703 5 25 inch floppy diskette VD9962003 TK50 tape cartridge 1 4 COMPATIBILITY AND REQUIREMENTS 1 4 1 HARDWARE TSDRIVER is compatible with DEC MicroVAX I and II computers It supports DEC TSV05 and TOK25 subsystems and TS11 emulations including Emulex TC02 TC03 and TC05 tape couplers General Description 1 1 Related Documentation 1 4 2 SOFTWARE TSDRIVER is compatible with the DEC MicroVMS operating system version 4 n The Program Development version of MicroVMS is necessary for full TS11 support because the DEC MTACP Magnetic Tape Ancillary Control Process is required however with the baseline MicroVMS system the TS11 can still be used for backup and restore operations as explained in subsection 2 3 1 5 RELATED DOCUMENTATION The following Emulex documents may be ordered from the following address Emulex Corporation 3545 Harbor Blvd Costa Mesa CA 92626 714 662 5600 TWX 910 595 2521 Title TC02 FS TS11 COMPA REPES Tape Coupler Technical Manual Publication No TC0251002 Title TC03 TS11 Compatible Tape Coupler Technical
3. AN Manual Publication No TCO351001 Title TCO5 TS11 Compatible Tape Coupler Technical Manual Publication No TCO551001 The following DEC publication is available from Digital Equipment Corporation P O Box CS2008 Nashua New Hampshire 03061 Titles MicroVMS User s Manual Publication No AA Z209B TE 1 2 General Description Section 2 INSTALLATION 2 1 OVERVIEW This section defines conventions and abbreviations used in this document and explains how to install TSDRIVER under MicroVMS 2 2 CONVENTIONS AND ABBREVIATIONS Operator input appears in boldface type in order to distinguish it from operating system messages and prompts The symbol lt return gt Signifies the carriage return key 2 3 INSTALLATION PROCEDURE The following installation procedure assumes that SPTREQ is set to 896 so that the command as shown SET SPTREQ 1024 adds 128 to the Current value This step is necessary only for the MicroVAX I which does not implement the Scatter Gather function TSDRIVER uses 128 entries in the system page table to perform this function so SPTREO must be increased by 128 This step is omitted for the MicroVAX II NOTE For the MicroVAX I SPTREQ must be increased by 128 for each tape drive that TSDRIVER serves l Login to the system manager account NOTE Before invoking VMSINSTAL you must install the System Programming Option SYSP To ensure that SYSP has been installed check the directory for the Magnet
4. EMULEX MICROVAX DRIVER DISTRIBUTION KIT VD9951803 REV G 3545 Harbor Boulevard Costa Mesa California 92626 VD9951903 Rev G 714 662 5600 TWX 910 595 2521 April 1986 Copyright C 1984 Emulex Corporation The information in this manual is for information purposes ang is subject to change without notice Emulex Corporation assumes no responsibility for any errors which may appear in the manual Printed in U S A TABLE OF CONTENTS Section Page ONE GENERAL DESCRIPTION INTRODUCTION aia ASA PRODUCT OVERVIEW micras ars 1 1 1 2 1 3 DISTRIBUTION MEDIA eoeooeeovoeeeeeeeooeoeeeoseo 1 4 COMPATIBILITY AND REQUIREMENTS eeeeoeeeooeooe 1 4 1 4 1 5 va Por A NN HEHE He o 1 Ha rdwa re 9 SE o 6 2 6 8 0 9 0 0 6 9 0 2 8 2 8 0 0 0 9 0 0 0 0 6 0 0 0 9 0 9 o 2 Sof twa re 8 8 80 SE CO ob 9 0 0 0 0 0 0 0 8 0 8 0 0 0 6 0 0 8 0 0 0 RELATED DOCUMENT AT ION 68 6 0 6 0 8 0 0 0 8 8 9 0 8 0 0 0 8 0 6 8 6 2 o 0 TWO INSTALLATION 2 4 OVERVIEW 223 anni Jel 2 2 CONVENTIONS AND ABBREVIATIONS ooooooooooonooo ooo 2 1 2 3 INSTALLATION PROCEDURE eeeeeeeneeeeoeeoeooeo 2 1 2 4 ERROR LOGGING ooooooosnoocorocsoncnnnsorcnnrsssno 2 2 2 5 MAKING A STANDALONE BACKUP DISKETTE oooooroooooo 2 3 EMULEX MicroVMS TS11 SOFTWARE DRIVER TSDRIVER INSTALLATION GUIDE 3545 Harbor Boulevard Costa Mesa
5. On the MicroVAX I ANALYZE ERROR LOG can be used to interpret the TS11 subsystem errors that are logged On the MicroVAX II however the tape error log module has been excluded so the user can only obtain a hex dump of the TS1l registers To obtain this dump use the following command ANALYZE ERROR_LOG REGISTER_DUMP INCLUDE MS lt return gt 2 5 MAKING A STANDALONE BACKUP DISKETTE The following procedure can be used for making a new version of standalone backup on RX50 floppy diskettes with TS11 support l Login on the system account 2 2 Installation Installation Procedures Invoke the editor and make a new modified version of the standalone backup build command file using the following command sequence The modified file should be called by a different name in this example TS11_STABACKIT vs STABACKIT in order to differentiate the two files Also the standard file needs to remain unmodified for future patches S SET DEF SYSSUPDATE EDIT OUT TS11 STABACKIT COM SYSSUPDATE STABACKIT COM lt return gt The following four steps are for MicroVAX I only F SRPCOUNT lt return gt I lt return gt SET SPTREO 1024 lt return gt z The following steps are for both MicroVAX I and II F TSDRIVER lt return gt S IJTFNOTUVAX lt return gt EXIT lt return gt Invoke the new version of the command file which will produce two rloppies with the new standalone backup You must have two scratch RX50 diskettes availa
6. ble SYSSUPDATE TS1 1_STABACKIT COM lt return gt Installation 2 3 BLANK EMULEX Reader s Comments Your comments and suggestions will help us in our continuous effort to improve the quality and usefulness of our publication Manual Part Number Rev What is your general reaction to this manual In your judgment is 1t complete accurate well organized well written etc Is 1t easy to use What features are most useful What faults or errors have you found in the manual Does this manual satisfy the need you think it was intended to satisfy Does it satisfy your needs CW J Please send me the current copy of the Controller Handbook which contains the information on the remainder of EMULEX s controller products Name tt to o vo zi m Street TUE ae oo o A o ee a City COMPANY _ ei AAA State Country DI Zip Additional copies of this document are available from Emulex Corporation 3545 Harbor Boulevard PO Box 6725 Costa Mesa CA 92626 Attention Customer Services Fold Here and Staple Do Not Tear Fold Here BUSINESS REPLY MAIL FIRST CLASS PERMIT NO 202 COSTA MESA CA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY ADDRESSEE EMULEX CORPORATION 3545 HARBOR BOULEVARD PO BOX 6725 COSTA MESA CALIFORNIA 92626 ATTN TECHNICAL PUBLICATIONS
7. ic Tape Ancillary Control Process MTAAACP EXE and the system symbol table SYS STB files Use the following procedures one at a time to make this check ES ih DIR SYS SYSTEM SYS STB lt return gt 2 DIR SYS SYSTEM MTAAACP EXE lt return gt Installation 2 l Installation Procedure 2 Insert the media and invoke the VMSINSTAL procedure For the floppy diskette enter the following SYS UPDATE VMSINSTAL DUAl lt return gt For the TK50 cartridge enter the following SYS UPDATE VMSINSTAL MUAO lt return gt 3 Invoke SYSGEN and alter the value of SPTREQ MicroVAX I only S RUN SYSSSYSTEM SYSGEN lt return gt SYSGEN gt USE CURRENT lt return gt SYSGEN gt SET SPTREO 1024 lt return gt SYSGEN gt WRITE CURRENT lt return gt SYSGEN gt EXIT lt return gt After completing these steps shut down the system and rebootstrap The default file SYLOGIN COM equates the INIT command to INIT NOHIGHWATER Magtapes do not support this option therefore an error occurs when you try to initialize the tape To overcome this problem you can either alter the SYLOGIN COM file not recommended or use the INIT HIGHWATER command to override the default INIT HIGHWATER MSA0 TEST lt return gt Failure to use the HIGHWATER qualifier may cause INIT to fail with the message shown in the following sample dialog INIT MSAO TEST lt return gt k INIT F ILLOPT gualifier s not appropriate to this device 2 4 ERROR LOGGING

Download Pdf Manuals

image

Related Search

Related Contents

Konica Revio KD-400Z Digital Camera  CATALOGO ZODIAC 2015 version Digital 17.12.14  

Copyright © All rights reserved.
Failed to retrieve file