Home

Manual - Enovate Medical

image

Contents

1. 30 5 40 IN ROOM CORRIDOR HEIGHT HEIGHT 40 MIN ABOVE FLOOR IF HUNG IN CORRIDOR FLOOR 30 5 ABOVE FLOOR IF HUNG IN PATIENT ROOM Mounting e MANUAL e550 Non Lift Mounting Diagram NOTE It is recommend that the e550 is mounted to wall studs _ WALL STUDS L Nu 16 TL 6 6 5 To t Power Data T Location 2 4 38 5 DIAMETER HOLE gt Ce en A e I amp 57 DIAMETER HOLE id LI sala lvl ila lalla L IN ROOM CORRIDOR HEIGHT HEIGHT F 29 5 30 5 40 IN ROOM CORRIDOR CENTER LINE HEIGHT HEIGHT 40 MIN ABOVE FLOOR IF HUNG IN CORRIDOR FLOOR 30 5 ABOVE FLOOR IF HUNG IN PATIENT ROOM Mountino In Room Installation STEP 1 Determine your desired keyboard height The dimensions on drawing see page 6 and 7 are shown for a keyboard height range of 30 5 to 42 5 Adjust dimensions as required for desired height STEP2 Locate the exact center line of the wall studs STEP 3 Using a level mark two horizontal lines at the distance from finish floor shown on the drawing on page 6 and 7 STEP 4 Drill 4 1 2 holes through the center of the wall studs and in
2. Enter the Master Code 2 Enter 13332 3 Enter the 5 digit time code for the required delay time from the table below 4 Pause for 2 seconds 5 The green LED flashes twice for success The new Delay Time has been saved and activated i 1 sec nus s uus Jm 11111 11112 11113 11114 11115 11121 11122 11123 11124 11125 28 Keypad Operations e MANUAL How to Setthe Proximity Sensor Range 1 Enter the Master Code 2 Enter 13325 3 Enter the 5 digit range code for the proximity sensor from the table below 4 Pause for 2 seconds 5 The green LED flashes twice for success The new range has been saved and activated RANGE CODE 29 30 31 32 33 enovate MEDICAL 1152 Park Avenue Murfreesboro TN 37129 p 888 909 8930 f 615 896 8906 www enovatemedical com support enovatemedical com 2014 Enovate Medical LLC All Rights Reserved
3. glass STEP 2 Remove VESA plate Thumb Nuts and remove the VESA plate from the wall station gt STEP 3 Mount VESA plate to monitor using the 4 M4x12 pan head screws provided STEP 4 Attach monitor and VESA plate assembly into wall station with the Thumb Nuts Do not fully tighten to allow for adjustment PLUG POWER CORD FROM WCC CONTROLLER INTO MONITOR STEP 5 Close the display glass Component Installation e MANUAL STEP Ensure that monitor is placed in the center of the frame and tighten thumb screws OI Y C 1 1 ST CPU Bracket The e550 is equipped with a universal CPU bracket that will accommodate CPU s with maximum dimensions of 10 5 x 10 5 x 2 6 STEP 1 Loosen thumb screw and move CPU bracket to its upper most position STEP 2 Put the CPU in place STEP 3 Loosen thumb screw and move the CPU bracket so it snugly holds the CPU in place Tighten thumb screw Optional Work Surface w Slide out Keyboard Tray STEP 1 Slide out keyboard tray STEP2 Remove 4 screws Optional Work Surface w Slid
4. opening state has been saved and activated How to Set the Open Mode for the Unit 1 Close the keyboard tray by pressing the Close switch 2 Enter the Master Code 3 Enter 13323 4 Enter the Open Code for the desired Open Mode from table below 5 Pause for 2 seconds 6 The green LED flashes twice for success The new Opening mode has been saved and activated OPEN MODE DESCRIPTION OPEN CODE Open by User PIN only 11111 Open by User PIN or Close button press 11112 Open by pulling down the keyboard tray 11113 Option 3 is for non locking units only 27 Keypad Operations e MANUAL How to Set the Close Mode for the Unit This option determines when the monitor willturn off The first option turns the monitor off when the proximity sensor timeout period expires due to the user walking away the user pushes the Close button or the keyboard tray is closed bythe user The second option turns off the monitor only when the keyboard tray is actually closed all the way 1 Close the keyboard tray by pressing the Close switch 2 Enter the Master Code 3 Enter 13324 4 Enter the Close Code for the desired Close Mode from the table below Pause for 2 seconds 6 The green LED flashes twice for success The new Closing mode has been saved and activated 7 Press the Close switch CLOSE MODE DESCRIPTION CLOSE CODE Prox Timeout Close Switch or Door Close 11111 How to Set the Proximity Sensor Delay Time 1
5. thumb and forefinger and NS E pull toward you until channel rests flush behind wall Slide GA f plastic cap along straps with other hand until flange of cap is flush with wall Metal Stud STEP 3 Snap straps at wall by push ing side to side snapping off straps level with flange of cap Patented under one or more of the follow ng U S Patent Nos 4 993 901 5 028 186 5 161 296 5 938 385 6 161 999 7 144 212 7 320 569 and foreign counterparts thereof and of 4 650 386 and 4 752 170 Other patents pending TOGGLER and typeface symbol TA TB TC TH ALLIGATOR SNAPTOGGLE and SnapSkru are worldwide registered trademarks of Mechanical Plastics Corp eLift Models Only Height Restriction Bracket Optional The e550 has an optional height restriction bracket that can be installed ifthere is a low ceiling condition where vertical travel is limited Refer to the following diagrams for three mounting options The height restriction bracket should only be used to prevent ceiling damage When the wall station comes into contact with the bracket it will shut the unit off OPTION 1 Restricts vertical movement to 6 total OPTION 2 OPTION 3 Restricts vertical movement Restricts vertical movement to 8 total to 10 total Component Installation MONITOR INSTALLATION STEP 1 Unlock and open the component door and display
6. A SAFE PLACE Adding a User PIN Code 1 Enter the Master Code 2 Enter 13344 3 Enter the PIN Code to add 4 Pause for 2 seconds 5 The green LED flashes twice for success The PIN Code has been saved and activated Deleting a User PIN Code 1 Enter the Master Code 2 Enter 13341 3 Enter the PIN Code to delete 4 Pause for 2 seconds 5 The green LED flashes twice for success The PIN Code has been deleted Deleting ALL User PIN Codes and Restoring the Default PIN Code 1 Enter the Master Code 2 Enter 13342 3 Pause for 2 seconds 4 The green LED flashes twice for success All User PIN Codes have been deleted and the factory default PIN code 54321 restored 26 Keypad Operations e MANUAL How to Turn On the USB Interface 1 Enter the Master Code 2 Enter 13321 3 Pause for 2 seconds 4 The green LED flashes twice for success The new state has been saved and activated When the USB interface is turned on key presses will be sent to the PC over USB just like a standard keyboard How to Turn Off the USB Interface 1 Enter the Master Code 2 Enter 13322 3 Pause for 2 seconds 4 The green LED flashes twice for success The new state has been saved and activated How to Set the Keyboard Light Opening State 1 Enter the Master Code 2 Enter 13331 3 Enter 11111 to turn the light on or 11112 to turn the light off at open 4 Pause for 2 seconds 5 The green LED flashes twice for success The new
7. RATIONS Lift amp or Locking Units Only Hardware HARDWARE INCLUDED uum 4X 10 x 2 1 2 SNAPTOGGLE Anchor Pan Head Screw 2x ay 4x ey 1 4 20 x 3 4 M4 x 12mm Button Head Screw Pan Head Screw Lift Models Only 1x 4X 99 4X ey Height Restriction Bracket 810 x 1 4 M4 x 16mm Lift Models Only Standoff Pan Head Screw 10x D 4x Cable Tie Dual Lock Pads Hardware e MANUAL TOOLS NEEDED Drill 1 2 Drill Bit Phillips Head Bit 1 8 Allen Wrench Mounting e MANUAL e550 with eLift Mounting Diagram NOTE It is recommend that the e550 is mounted to wall studs Optional Power Data Location pum r Power Data Location pal I u gt lt E I I lt E I u I gt I I 4 af s s FTT FTT MAN MN BE E lli lli pr _ 5 DEE m e gl A m T ell 42 15 ll 5 Fg 45 EC AI ba E s ri _ 57 DIAMETER HOLE 1 i T selalvivizisials l Sa EE EE 17 p4 I M 47 5 57 IN ROOM CORRIDOR HEIGHT HEIGHT T 1 57 ape gt C Hi 29 5 4
8. and mouse into the USB hub that is pre wired into the keyboard tray Cleaning Instructions Use non abrasive cleaners or mild cleaning solutions Do not use abrasive cleaners solvents polishes waxes or steam cleaning tools As a precaution to test the suitability of a cleaning product apply to an inconspicu ous area minimizing the time of exposure and the amount of cleaning agent dilut ing as recommended by the supplier in order to prevent any damage to the surface Contamination by intensively colored substances for example coffee mustard curry or red wine have to be removed immediately 21 Keypad Operations Electronic Lift amp or Locking Units Only enovate Keypad There are five keys that are used to enter 5 digit PIN codes LED A single multi color LED on the keypad provides feedback to the user as key sequences are pressed The LED can appear as green or red LED COLOR FLASH ONCE FLASH TWICE Each key press Successful operation Master Code There is one 5 digit Master PIN Code for use by the system adminis trator The Master Code is used to assign User PIN Codes and for other maintenance functions The factory default Master Code is 12345 User PIN Codes Up to 100 5 digit PIN Codes can be assigned for use by hospital personnel to access the wall cabinet keyboard When a user enters their valid PIN code the keyboard drawer unlocks and can be opened by u
9. board amp Mouse Three Way 25 E B B ES Power Splitter ur SED nern Mis e ines et MR OR An s CAOVALE DD wan stani sale Bes A B ene Pre Wired Pre Wired To M oii Power Brick q D SUSE To WCC Power In mu 0 gg To Monitor Pre Wired To PC Power From Power Splitter FINISHING UP NON LIFT 1 Attach the USB cable from the WCC Controller Box to the PC 2 Plug LCD VGA cable into CPU 3 Plug the power from the two way splitter to the PC Power Pre Wired for amp Mouse N E 0 Bal l OU Keyboard To PC USB Additional Power To PC Power WCC CONTROLLER BOX 7 PC E MED L 108 NMR SWH KEYBOARD 20 ED ACTUATOR MAGNETS 8 Ry vowel DI VS car 32 E BUF WARNING i ola D es gota 0 ye To Monitor V Pre Wired From Power Splitter Two Way Power Splitter LWCC Controller Box THREE WAY SPLITTER To AC Power Three Way Power Splitter Pre Wired To WCC Power In Additional Power Source To PC Power 3 Mount keyboard to keyboard tray with supplied 3M Dual Lock Squares Be sure keyboard does not cover round metal plate 4 Plug keyboard
10. ds ELECTRICAL SHOCK HAZARD Cutting or drilling into electrical wires and cables can cause FIRE DEATH or SERIOUS PERSONAL NJURY Always make certain the area behind the mounting surfaces is free of electrical wires and cables before drilling into wall EXPLOSION AND FIRE HAZARD Drilling into gas plumbing can cause EXPLOSION FIRE DEATH or SERIOUS PERSONAL INJURY Always make certain the area behind the mounting surface is free of gas water waste or any other plumbing before drilling GROUNDING Connect the Enovate Medical Wall Station to a grounded receptacle SERVICE AND REPLACEMENT Do not attempt to service or replace any part of the Enovate Medical Wall Station unless directed to do so through Enovate Medical approved documentation i e this User Manual or other instructions Only Enovate Medical or an Enovate certified entity may service or replace the wall station compo nents If any component on the wall station is missing or damaged the wall station must not be used Contact Enovate Medical immediately to request service If the unit is not working properly please contact Enovate Medical Customer Service toll free at 888 909 8930 or by email at support denovatemedical com 18 21 Table Of Contents MANUAL WELCOME WARNINGS HARDWARE MOUNTING HEIGHT RESTRICTION BRACKET COMPONENT INSTALLATION UNIVERSAL CPU BRACKET OPTIONAL WORK SURFACE W SLIDE OUT KEYBOARD TRAY ADJUSTMENTS KEYPAD OPE
11. e Wallstation enovate The Enovate Medical e550 Wallstation was designed to set a new standard in quality Enovate Medical s goal is to provide a wallstation ready for years of use and backed by a commitment of exemplary service and support Thank you for purchasing the Enovate Medical e550 Wallstation enovate MEDICAL 2013 Enovate Medical LLC All Rights Reserved Content is subject to change without notification IMPORTANT WARNINGS Read the entire installation manual before you begin MOUNTING Installer must verify that the entire wall will safely support the combined weight of all attached equipment and hardware Improper installation of this product can cause extensive property damage or serious personal injury either during or after installation It is the responsibility of the installer to ensure that all applications including wood concrete block brick steel etc are secured properly and are in compliance with local and national building codes California installations could require specific anchorage and additional mounting screws Check with local authorities for codes in your area Other seismic states have similar regulations WARNING Because wall surfaces and construction methods and materials vary it is imperative that you consult with the appropriate engineering architectural or construction professional to ensure hat your Wall computing station is mounted properly to handle the applied loa
12. e out Keyboard Tray e MANUAL STEP 3 jack wired Plug mouse and keyboard USB cords into pre Using cable ties secure excess wire to tie pads NOTE Leave just enough slack for keyboard tray to slide all the way out asas Replace 4 screws STEP 4 17 Aqjustments KEYBOARD TRAY GAS SPRING ADJUSTMENT STEP 1 To adjust the keyboard tray closing tension turn adjustable gas spring bracket screw Turn clockwise to increase tension and counterclockwise to decrease tension NOTE Do not over adjust as this may defeat the closing mechanism LATERAL ADJUSTMENT Turn front spiral tech cam screw to increase or decrease door overlay DEPTH ADJUSTMENT Turn rear spiral tech cam screw to adjust door position HEIGHT ADJUSTMENT Rotate cam screw on plate to adjust door position Adjustments e MANUAL FINISHING UP eLIFT non lift see page 20 1 Attach the USB cable from the WCC Controller Box to the PC 2 Plug LCD VGA cable into CPU 3 Plug the power from the three way splitter to the PC Power Actuator Power Brick To AC Power o e A e Three Way Power Splitter WCC Controller Monitor Power WCC CONTROLLER B0X THREE WAY SPLITTER To AC Power Pre Wired for To PC Key
13. keyboard tray away from edge 3 Press to close keyboard tray 24 Keypad Operations e MANUAL eLift Models Only Adjusting the Wall Unit Height 1 Press and hold the Up or Down switch to adjust the height of the wall unit There isa 12 height adjustment from the lowest keyboard height unless the height restriction bracket has been installed Activating the Keyboard Light MEDICAL MEDICAL 25 Keypad Operations e MANUAL Administrative Functions ALL code entries reguire five key presses Too few or too many key presses will result in a failed operation NOTE All administrative func tions must be completed with the keyboard tray in the closed position Please note that in all of the following examples it is advised to have all key strokes written down for the desired operation If there is a pause of 2 seconds or longer between any two keys the red LED will flash twice to indicate a failure To cancel an operation stop pressing keys and let the operation fail due to a timeout When an operation com pletes successfully there will be two green flashes Changing the Master Code 1 Enter the current Master Code 2 Enter the current Master Code again 3 Enter the new Master Code 4 Pause for 2 seconds 5 The green LED flashes twice for success The new Master Code has been saved and activated IMPORTANT RECORD YOUR MASTER CODE AND SAVE IT IN
14. ser to allow access Additionally the LCD monitor is turned on and additional keys on the keypad become enabled for adjusting the height of the wall unit turning on the optional keyboard light and for closing the keyboard drawer The factory default User PIN Code is 54321 22 Keypad Operations e MANUAL Reserved PIN Codes The following PIN codes are reserved for administrative usage These codes cannot be assigned as either the Master Code or as a User PIN Code Factory Defaults Summary For Locking Units All units are shipped from the factory with the following default values Keyboard Tray Unlock Time Keyboard Light Opening State Open Mode User PIN only Close Mode Prox timeout Close switch or door close 23 Keypad Operations e MANUAL USER FUNCTION LOCKING KEYBOARD TRAY PIN TO OPEN 1 Enter your assigned PIN code wait until green light flashes DO NOT PRESS THE BUTTON 2 Pull keyboard tray down 3 Log on to computer NOTE You must be standing in front of the wallstation for keyboard tray to remain open TO CLOSE 1 Log off computer 2 Slide mouse toward back of keyboard tray away from edge 3 Press d mf to close keyboard tray NON LOCKING KEYBOARD TRAY TO OPEN 1 Pull keyboard tray down 2 Log on to computer NOTE You must be standing in front of the wallstation for keyboard tray to remain open TO CLOSE 1 Log off computer 2 Slide mouse toward back of
15. stall 4 SNAPTOGGLE brand hollow wall anchors See wall anchor installation instructions on page 10 STEP 5 Screw Wallstation to the wall using the 10 Pan Head Screws provided Check the Wall Station for level before tightening completely Corridor Installation STEP 1 FOR CORRIDOR INSTALLATION THE WALLSTATION IN CLOSED POSITION MUST BE A MINIMUM OF 40 ABOVE FLOOR AND 2 ABOVE CORRIDOR HANDRAIL OR ANY OBSTRUCTION PER CMS REGULATIONS STEP 2 Locate the exact center line of the wall studs STEP 3 Using a level mark two horizontal lines at the distance from finish floor shown on the drawing STEP 4 Drill 4 Y holes through the center of the wall studs and install 4 SNAPTOGGLE brand hollow wall anchors See wall anchor installation instructions on page 10 STEP 5 Screw Wallstation to the wall using the screws provided Check the Wallstation for level before tightening completely METAL STUD MOUNTING Back Plate Wall Metal Stud RUN p gt II 10x2 1 2 Pan Head Screw Mounting e MANUAL SNAPTOGGLEG HOLLOW WALL ANCHOR INSTALLATION STEP 1 Drill a Y hole through cen ter of metal stud Hold metal channel flat alongside plas tic straps and slide channel through hole Must be 1 7 8 minimum clearance behind wall for channel rotation STEP 2 gt cr vestsud Hold ends of straps between Vim EES

Download Pdf Manuals

image

Related Search

Related Contents

  para más información descarga ficha en pdf  Toshiba Satellite L655D-S5066  Année 2008 - Centre interdépartemental de gestion de la petite  Biotek ELx50 - Frank`s Hospital Workshop    7ページ(PDF:710.6KB)  Jetzt downloaden  APC Rack PDU  MUPR-H3M - MundoClima  

Copyright © All rights reserved.
Failed to retrieve file