Home

GSM Alarm System With built-in PIR sensor

image

Contents

1. 10 seconds system is in arm wait status 10 seconds later the signal LED will flash quickly in green system is in home arm status now You can set home arm mode when there is some one at home sensors in inner defense zone will be invalid but sensors in other defense zones still work normally Disarm key Press this button all the detectors are disarmed the light on panel will keep on in green Alarm key Press this button the light on panel will flash in red the system will be alarming and the host will send the SMS and dial out How to add more detectors You can add more sensors and detectors such as wireless door sensors PIR sensors gas and smoke detectors into the host 1 Add sensors ready to work when you set both Out Arm and Home Arm When the GSM host begins to be powered on the status LED light on panel will be red for 20 seconds this is code learning mode You can trigger the sensors or detectors and the red LED will flash to show it is coded successfully into the host The coding mode ends 20 seconds later automatically and system enters into working mode status LED light on panel will change to yellow then to green 2 Add sensors into inner defense zone Detectors in this zone are ready to work when you set Out Arm and will not work when you set Home Arm PDF CPP pdfFactory Pro what www fineprint cn When the GSM host begins to be powered on the status LED light on panel will be red Push the reset button fo
2. 7 kinds of alarm messages in the host The first five messages are for wireless detectors of zone 1 5 the sixth message is for wireless detectors of zone 6 16 and the seventh message is for built in PIR sensor If the first wireless detector is triggered the alarm message is Wireless Activated 01 If the second wireless detector is triggered the alarm message 1s Wireless Activated 02 If the third wireless detector 1s triggered the alarm message is Wireless Activated 03 If the fourth wireless detector is triggered the alarm message 1s Wireless Activated 04 If the fifth wireless detector is triggered the alarm message is Wireless Activated 05 If the sixth to sixteen wireless detector is triggered the alarm message is Wireless Activated 1 126 16 If the built in PIR detector is triggered the alarm message 1s Wired Activated 1 3 Users can send command to the host to change these 6 kinds of alarm messages The alarm message cannot be more than 24 English characters 123456168 1f Front door open save first group message into the host as first wireless detector is triggered 123456 82 Middle door open save second group message into the host as second wireless detector is triggered 123456 83 Back door open save third group message into the host as third wireless detector is triggered 123456 84 Front window open save fourth group message into the host as fourth wireless detector is triggered 123456 85 Back window open save f
3. AL light still flashes in orange it shows SIM card is fixed incorrectly or GSM network is poor If SIGNAL light still on in green it shows no name or phone numbers in SIM card If every thing is ok SIGNAL light will flash slowly in green out arm mode or flash quickly in green home arm mode or keeps on in green disarm mode If alarm happened SIGNAL light will flash in red and start to dial out and send SMS 2 About Speaker light If the host speaker is in working mode the output 3 will be on showing you can talk or speak to scene 3 About Alarm light When this light s on means wireless scene alarm siren will alarm if the light s off which means the wireless scene alarm siren won t alarm You can connect extra wireless siren to this system by code command 6 PDF EH pdfFactory Pro BUHRhRAB EE www fineprint cn 4 About MONINTOR light If the monitor function is opened the monitor light will be on If the monitor function is closed the monitor light will be off How to install 1 Installation of the Host a Try to install the host in the center of the defense zone and prolong the antenna for getting more wireless signal receiving distance b The installation position should be far away with huge metal objects and wireless devices C this host used for detecting if someone moves within in a certain place Fix it on the wall 2 2 2meters high and you should adjust the position to make it face to the defe
4. GSM Alarm System With built in PIR sensor Installation and Users Guide l PDF HEH pdfFactory Pro WHWR EEJ www fineprint cn Brief Introduction GSM 900 1800 1900 bands can be used in most parts of the world Monitor the scene environment Voice and message alert Set alarm ON or OFF by remote controller Can set Home Arm and Out Arm mode Call in to set alarm ON OFF Monitor Output and Intercom Send SMS to set alarm ON OFF Monitor Output 5 group phone Can program 7 groups of alarm messages 16 zones for wireless detector SMS inform if external power failure or recovery w 9999 99 999 Basic Kit contains Alarm system control unit 1 pc Remote controller 2 pc Antenna Ipc Door magnet Ipc Power supply with back up Ipc Installation user manual Ipc Installation guide Bracket spot Antenna Batte attery Power switcht Reset button SIM card tra Product update port Socket 1 Insert SIM into the alarm unit Open the back cover of the unit slide the SIM card carefully into the tray and make sure the metal contacts of the SIM to be down see picture 1 Note Before inserting SIM card into alarm unit using a regular mobile phone to do the following steps Set PIN code requested to off Delete all stored numbers 2 Connect the antenna Screw the antenna to the connection on the back of the main unit Take care not to over tight the nut or let it 2
5. PDF HEH pdfFactory Pro HARA GS www fineprint cn loose 3 Insert the power supply Connect the host with the adaptor The host need 9V 12V DC must be over 1000mA current The signal status LED on the main unit panel will turn to red and last for 20 seconds this is code learning mode system is waiting for wireless detectors to be coded into the host After 20 seconds the signal status LED will turn to orange and begin to flash indicating system is checking SIM card and search for GSM network After the main unit finishing checking the host if the signal status LED turns to green and flashes slowly it shows alarm phone number have been saved in the host and the host is in arm status If the signal status LED keeps on in green it shows phone numbers have not been saved in the host and the host is in disarm status You can dial in the host or send SMS to program the phone number How to setup the alarm phone numbers and SMS 1 You can send command to the host to setup 5 groups of alarm phone numbers The format is Password operation code content 123456 5 1 13907550001 save first group alarm phone number into the host 123456 52 13907550002 save second group alarm phone number into the host 123456 53 13907550003 save third group alarm phone number into the host 123456 54 13907550004 save fourth group alarm phone number into the host 123456 55 13907550005 save fifth group alarm phone number into the host 2 There are
6. ifth group message into the host as fifth wireless detector is triggered 123456 86 Middle window open save sixth group message into the host as sixth sixteenth wireless detector is triggered 123456 87 PIR sensor triggered save seventh group message into the base as PIR sensor triggered PDF EH pdfFactory Pro what www fineprint cn How to operate when the host is alarming In normal usage if the host is in disarm status the signal LED keeps on in green You can use remote controller to change the host into arm status or you may send command 123456 1 1 to the host to change the host into arm status the signal LED will flash in green in arm status l Under arm status any wireless detectors activated or press of alarm key of the controller the alarm system will send alarm information by SMS and dial out stored telephone numbers The system will send preset alarm message before dialing alarm phone numbers If the SMS has been closed or limited it will only dial out the alarm telephone numbers When there is alarm you can answer the phone no need to input password for listen in remote control Press 3 1 to sound the siren and press 3 0 to stop it press 4 1 to start to listen in and press 4 0 to stop it After picking up alarming calls if you do not need the host dial next phone number programmed in the host just press 1 1 or 1 2 to re turn the host to arm status When there is alarm users can also use the cont
7. n Current lt 20mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 rh Remote Control Power Supply DC12V inner DC12V battery Transmission Current x15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m PDF CePA pdfFactory Pro iUJUHARAKBUEE www fineprint cn
8. nse zone Window NOTE a Adjust the detecting angle try to make the detecting window plumb to the direction of people s walking b Keep away from the heat or air conditioner blowing and air convection area close the window amp door when alarm the detector c Make the obstacles and floating objects away from the detecting area such as the clothes durtain and flowers d Make the detector steadily installed without any shake and trembling e Keep away from the direct sunlight irradiation f If the light in the PIR keep on it shows battery fails So please replace it as soon as possible 2 Installation of Door Sensor Low Power LEU Work LED A We define the Magnetic door window contact for 2 parts part A and part B First pack the battery into the part A and then according to the show of sketch map to fis part A and part B with screws on the monitored door window It is 7 PDF EH pdfFactory Pro what www fineprint cn better if the distance between them is closer x15mm between part A and part B NOTE a Magnet should be close to signal status and make the transmitter box and magnet as close as possible 10mm b In order to get the best receiving distance you should pull the antenna and make it upwards c If the indicator lights of door sensor are still blinking it shows battery fails So please replace it as soon as possible Standard components and optional available components The follo
9. r one second the status LED light will light up in orange for 20 seconds This is code learning mode of inner defense zone You can trigger the sensors or detectors the LED will flash in red to show it is coded successfully into inner defense zone For above operation the host will exit code learning mode 20 seconds later automatically and enters into working mode the light on panel changes to orange to search for GSM network then to green Note If there were 4 wireless sensors in the host stand for zone 1 to zone 4 then the new added sensor will be 5th zone in the host How to cancel the lost detectors In case some of the coded detectors are lost you can cancel the coded information of this detector so that it can not control your alarm system Follow the below operation to reset the alarm system Keep pressing the reset button then power on the system Siren beeps once or LED flashes once it shows reset is successful All registered detectors have been deleted You can register them again with the above mentioned process System reset will not change SMS message SOME NOTES Monitor Speaker MIC Status PIR Detector 1 About Status light SIGNAL light keeps on red in 20 seconds after the host is powered on wireless detectors can be coded into the host this time The light flash in red if coded successfully 20 seconds later SIGNAL light flash in orange to show it starts to search for GSM network If SIGN
10. roller to disarm the host if they are near by In normal usage with inside recharge battery on you will receive the message external power failure or external power recovery when external power supply lost or recovered How to control the host 1 Sending message to the host phone number SIM Card number Send the message to the host enter password 123456 add the following command to set the host 2 Calling the host phone number SIM Card number Call in the host and enter password 12345645 then input the following command to set the host Com 13 15 13 0 3814 4 1 12 1 15 1 30 31 38 39 SO H 5 1 S3H SS S Ott Disarm all detectors otw p Just alarm and no dialing Change password Enter a new password 1 6 bit Set up alarm of zone wireless zone 1 16 Built in PIR zone 21 NOTE arm of single defense zone Turn off alarm of zone wireless zone 1 16 Built in PIR zone 21 NOTE disarm of single defense zone show preset phone number in the host SMS command applicable only First group phone number 0 1 5bit 52 Second group phone number 0 15bit Third group phone number 0 1 5bit 54 fourth group phone number 0 15bit show preset SMS in the host SMS command applicable only 8 1 First group Message 0 24bit 82 Second group Message 0 24bit S3 Third group Message 0 24bit S4 Fourth group Message 0 24bit PDF EH pdfFactory Pro WHW ww
11. w fineprint cn S5 Fifth group Message 0 24bit S6 Sixth group Message 0 24bit Sm Seventh group Message 0246i Note 1 Above table stands for default setting 2 In the above phone operation one beep shows the number your input is successful a long beep shows the sentence you input is successful two short beeps show sentence you input is failed you should try again 3 Inthe above SMS operation you will receive a reply message for confirmation after sending message command to the host Such as DisArm Sms ON Phone ON Siren ON Center Tel OFF Arm Center Tel OFF DisArm Center Tel OFF If the replied message is about the current status of the host you may have sent wrong command You can also send inquiry command to check out the present status of the host 5 When the external power is cut off the system will send SMS Power changer off to inform When the external power resumed the system will send SMS Power changer on to inform How to use remote controllers wi There are four buttons on the remote controller Out Arm key Press this button the signal LED flash slowly in orange for 10 seconds system is in arm wait status 10 seconds later the signal LED flash slowly in green system is in out arm status now You can set out arm mode when no one is at home all the detectors at home will be in working mode Home Arm key Press this button the signal LED flash slowly in orange for
12. wing sensors can be optional Additional wireless products Smoke Detectors Panic Butt ons L es C a Door Window Remote Controls LPG Gas Detectors gap sensors Optional sensors detectors are packed separately It includes remote controllers wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc You may purchase according your specific requirements Typical house configuration Py 4 External Sirenz patet Remote cantral E garage m Smoke r FIR Mower ent Detector a Detectors PDF EH pdfFactory Pro WHW www fineprint cn SOME TECHNIQUE PARAMETER 1 Static current 20mA Power 9V 12V DC Working temperature 20 C 85 C GSM850 900 1800 1900MHz band Receiving code ASK Frequence 315 433 868 915MHZ wireless distance 100 M wireless detectors 16 wire detectors 3 Outer Alarm Siren Volume 110 dB Working Condition Temperature 10 C 40 C Humidity lt 90 rh Wireless Gap Detector Door Window Contact Power Supply DCI2V inner 12V battery Static Current lt 20 mA Transmission Current x15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Internal Distance 15 mm Working Condition Temperature 10 C 40 C Humidity lt 90 rh Wireless P IR Detector Power Supply DC9V inner 9V battery Static Current lt 100 mA Transmissio