Home
USER MANUAL - Medical Dynamics, Inc.
Contents
1. 6 7 Adjust pressure To INCREASE pressure Turn Knob CLOCKWISE To DECREASE pressure Turn Knob COUNTERCLOCKWISE 8 Begin procedure 9 When procedure is complete press the On Off Switch to the OFF position CLEANING MAINTENANCE AWARNING Turn the Easy Comp Compressor off and disconnect from any external power source before cleaning NOT attempt to repair There are no user serviceable parts inside To clean the filter weekly 1 Unplug Compressor 2 Pry off filter end cap to check air filter for dust buildup 3 If dust buildup occurs remove air filter and wash in warm soapy water and rinse 4 Absorb excess water from filter with a dry towel 5 Return filter and end cap Cleaning for Exterior Components Use a clean cloth or sponge dampened with soap and water Wipe dry with a clean cloth or paper towel CAUTION e Excessive dust buildup on filter will reduce performance of Compressor If this occurs clean or replace with a new filter The air filter does not filter out saline Treatments using nebulized saline will draw the saline mist back into the Compressor Saline cause rapid deterioration of the compressor seals and will void the warranty Wi RETURNS Returned products require a Returned Goods Authorization RGA number contact Precision Medical Inc All returns must be packaged in sealed containers to prevent damage Precision
2. INTENDED USE The basic function is to supply a portable compressed air source adequate to drive the high volume nebulizers READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Easy Comp Compressor This is provided for your safety and to prevent damage to the Compressor If you do not understand this manual DO NOT USE the Compressor and contact your Equipment Provider EXPLANATION OF ABBREVIATIONS psi Pounds Per Square Inch lpm Liters Per Minute SAFETY INFORMATION WARNINGS AND CAUTIONS indicates an imminently hazardous situation which if not avoided will result in death or serious injury AWARNING ndicates a potentially hazardous situation which if not avoided could result in death or serious injury ACAUTION ndicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CONSULT ACCOMPANYING DOCUMENTS ft Type B Equipment fo ADANGER To reduce the risk of electrocution e Always unplug Easy Comp Compressor immediately after using NOT use while bathing DO NOT place or store Compressor where it can fall or be pulled into a tub or sink DO NOT place or drop into water or other liquid DO reach for a Compressor t
3. KEEPER GROUNDING INSTRUCTIONS The product should be grounded In the event of an elec trical short circuit grounding reduces the risk of electrical shock by providing an escape wire for the electrical current This product is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded ADANGER electrical shock Improper use of the grounding plug can result in a risk of AWARNING Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked Hospital Grade OPERATING INSTRUCTIONS AWARNING Read this User Manual before installing or operating the Easy Comp Compressor CAUTION Inspect the Easy Comp Compressor for visual damage DO NOT USE if damaged o1 B PO O Press the On Off Switch to the ON position Place Easy Comp Compressor near a properly grounded electrical receptacle on a table floor or other horizontal smooth hard surface Allow a minimum of 4 in 10 cm clearance on all sides to ensure adequate air flow for cooling of product Press down on product until Suction Feet are secure sure the On Off Switch is in the OFF position Plug the Compressor into a properly grounded receptacle Attach appropriate device to the Outlet Fitting securely without overtightening
4. Medical Inc will not be responsible for goods damaged in transit Refer to Precision Medical Inc Return Policy available on the Internet www precisionmedical com DISPOSAL INSTRUCTIONS Dispose of Bio waste products as prescribed by your Healthcare Professional or Healthcare Facility Protocol AWARNING If Compressor is used for treatment of infectious disease consult your Physician or Healthcare Professional for recommended procedures for proper disposal Please Recycle Ly Ka REPLACEMENT PARTS Description Part Number Filter Assembly 1834 Filter Case 10 ea 1841 10 TROUBLESHOOTING If the PM50 Easy Comp Compressor fails to function consult the Troubleshooting Guide If the problem cannot be corrected consult your Equipment Provider Problem Probable Cause Remedy A Compressor 1 On Off switch in 1 Push On Off will not OFF position switch to ON operate 2 Power cord position not connected 2 Check power properly cord 3 Compressor 3 Shut Compressor overheated off wait 15 minutes be sure vents are clear B Unable 1 Defective 1 Contact to adjust regulator Equipment pressure Provider C Overheating 1 Poor Ventilation 1 Move Compressor to a cooler better ventilated area D Low pressure sit 1 Loose connection at outlet fitting Improper regulator adjustment Tighten connection Readjust r
5. USER MANUAL COMPRESSOR Model 50 SAVE THESE INS TRU NS ACAUTION Federal USA law restricts this device to sale by or on the order of a physician Your local distributor PRECISIONG MEDICAL N Medical Dynamics TECHNOLOGY OF THE FUTURE TODAY 300 Held Drive 866 624 3952 Northampton PA 18067 USA www thinkMDLnet www precisionmedical com 5 0 000 000 2 INTENDED USE co 2 READ ALL INSTRUCTIONS BEFORE USING 2 EXPLANATION ABBREVIATIONS 2 SAFETY INFORMATION WARNINGS AND CAUTIONS 2 SPECIFICATIONS 4 COMPONENT IDENTIFICATION 444 5 GROUNDING 5 202 2 6 OPERATING 85 2 40000 6 CLEANING MAINTENANCE 7 RETURNS 8 DISPOSAL INSTRUCTIONS 8 REPLACEMENT PARTS 8 5 5 10 RECEIVING INSPECTION Remove the Precision Medical Easy Comp Compressor from packaging and inspect for damage If there is any damage DO NOT USE and contact your Equipment Provider
6. egulator LIMI AND LIMITATION OF LIABILITY Precision Medical Inc warrants that the PM50 Easy Comp Compressor the Product will be free of defects in workmanship and or material for the following period One 1 year from shipment Should any failure to conform to this warranty appear within the applicable period Precision Medical Inc shall upon written notification thereof and substantiation that the goods have been stored installed maintained and operated in accordance with Precision Medical Inc s instructions and standard industry practice and that no modifications substitutions or alterations have been made to the goods correct such defect by suitable repair or replacement at its own expense ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES The representatives of Precision Medical Inc or any retailers are not authorized to make oral warranties about the merchandise described in this contract and any such statements shall not be relied upon and are not part of the contract for sale Thus this writing is a final complete and exclusive statement of the terms of that contract THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY WHETHER EXPRESS OR IMPLIED Precision Medical Inc shall not under any circumstances be liable for special incidental or consequential damages including but not limited to lost profits los
7. hat has fallen into water Unplug immediately e NOT attempt to repair Compressor Any attempt could result in electrical shock NOT use near any type of flame or flammable explosive substances e allow Compressor to exceed operating or storage temperature specifications e Caution must be exercised when using this Compressor where oxygen is being administered AWARNING To reduce risk of burns electrocution fire or injury to persons The Easy Comp Compressor should never be left unattended when running e Close supervision is necessary when the Compressor is used by on or near children or invalids e Use this Compressor only for its Intended Use as described in this manual DO use attachments not recommended by Precision Medical Inc DO NOT use Compressor with any equipment that requires dry air including ventilators gas blenders or flow generators use if Compressor has a damaged cord or plug DO NOT use if Compressor has been dropped or damaged NOTcover air vents Restriction of air flow will cause unit to overheat causing the thermal reset to shut down the Compressor drop or insert any object into any opening or hole Connect this Compressor to a properly grounded outlet only See Grounding Instructions Keep the cord away from heated surfaces st 3 ACAUTION If f
8. or any reason any label becomes illegilble or lost contact Precision Medical Inc CAUTION Inspect the Easy Comp Compressor for visual damage DO NOT USE if damaged e Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked Hospital Grade SPECIFICATIONS Flow Output at 50 psig 15 Ipm minimum Maximum Rated Sustained Pressure 60 psi Duty Cycle 50 Dimensions Length 10 25 in 26 0 cm Width 5 25in 12 3 Height 9 5 in 24 1 cm Weight 10 8 16 4 9 kg Shipping Weight 12 5 16 5 7 kg Electrical 120 VAC 60 Hz 5 Amps Operating Temperature Range 50 F to 104 F 10 C to 40 C Storage Temperature Range 4 to 120 F 20 C to 49 C Outlet Grounded 9 16 18 Male Threaded Fitting Safety Systems High Temperature Motor Shutdown Thermal Protector Class B Thermal Limit Automatic Reset This Easy Comp Compressor is not suitable for use in the presence of a flammable anesthetic mixture with air with oxygen or with nitrous oxide Specifications are subject to change without prior notice EASY COMP COMPONENT IDENTIFICATION ACAUTION Missing or illegible labels must be replaced contact Precision Medical Inc PRESSURE GAUGE FITTING OUTLET SS ae i J REGULATOR FILTER ENDCAP Air FILTER ASSEMBLY On Swirch 3 i s i Power Corp
9. t sales or injury to person or property Correction of non conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical Inc whether based on contract negligence strict tort or otherwise Precision Medical Inc reserves the right to discontinue manufacture of any product or change product materials designs or specifications without notice Precision Medical Inc reserves the right to correct clerical or typographical errors without penalty PRECISION MEDICAL Precision Medical Inc 300 Held Drive Northampton PA 18067 USA Toll Free Tel 800 272 7285 Toll Free Fax 800 353 1240 Tel 001 610 262 6090 Fax 001 610 262 6080 www precisionmedical com ISO 13485 Certified 1971 Rev7 E 05 22 07 PRINTED IN USA
Download Pdf Manuals
Related Search
Related Contents
appendice manuale officina motore anhang werkstatt Sharp XG-P560WN data projector safety instructions and quick start guide duo d30 Philips AQ6560/00G User's Manual FORD SÉRIE F Manual do Proprietário Siemens EH7752UC User's Manual FRAX 101 Sweep Frequency Response Analyzer InLine 35300X we strive to promote “sound learning.” クリック Copyright © All rights reserved.